the savings with energy efficient led lighting is realized before the first fixture is turned on
TRANSCRIPT
![Page 1: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/1.jpg)
The savings with energy efficient LED lighting is realized before the first
fixture is turned on.
![Page 2: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/2.jpg)
You will incur lower costs because of the reduction in construction
materials wheninstalling the fixtures.
![Page 3: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/3.jpg)
• Fewer circuits required• Fewer junction boxes and
covers• Reduced
need for bends
and hangers
![Page 4: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/4.jpg)
• Reduced need for EMT and BX • Lighter gauge wire used• Installation of fewer fixtures
![Page 5: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/5.jpg)
Fewer lights willbe installed as LED hasgreater output than HighPressure Sodium or Fluorescence.
![Page 6: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/6.jpg)
In new construction ceiling vacant space between floorscan be reduced as large troffer fixtures do not
need space to dissipate heator be maneuvered in the
space for maintenanceor replacement.
![Page 7: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/7.jpg)
LED flat panels are slimmer than a pizza box.
![Page 8: The savings with energy efficient LED lighting is realized before the first fixture is turned on](https://reader030.vdocuments.net/reader030/viewer/2022032606/56649ead5503460f94bb4667/html5/thumbnails/8.jpg)
The average 20-amp breaker will carry 2400 watts. The load should equal 80% which equates to 1932 watts. Most current construction jobs are using 102 watt troffers at 2850 lumens (with a
lumens loss in 200 hours.) Only 18 may be placed on one circuit.
NEUTEX 40 watt flat panels at 2150 lumens retains 80% of lumens for 50,000 hours. 47 flat panels may be placed on the same 20-amp circuit.
Troffer vs. LED Flat Panel Comparison