the status of the scintillator-based calorimetry r & d activities in korea donghee kim kyungpook...

26
The Status of the Scintilla tor-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1, 2005

Upload: cornelius-butler

Post on 26-Dec-2015

219 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

The Status of the Scintillator-based Calorimetry R & D Activities in Korea

DongHee KimKyungpook National University

3rd ILC Workshop(Konkuk U.) Apr 1, 2005

Page 2: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Collaboration

KOREAKyungpook National University

Seoul National UniversitySungKyunKwan University

JAPANKobe University

Shin-Su UniversityNiigata University

Tsukuba University

RUSSIADubna

Page 3: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Collaborators(Korea)

DongHee Kim, Kihyeon Cho, Jun Suhk Suh, Youngdo Oh,Daejung Kong, Hongjoo Kim, Jieun Kim, Yuchul Yang,

Sunghyun Chang, Kukhee Han, Shabeer Mian, Adil Khan

Kyungpook National University

Soo Bong Kim, Kyungkwang Ju, Eunjoo Jun, Hyunsoo Kim,Youngjang Lee, Byungsoo Yang, Jieun Jung

Seoul National University

Intae Yu, Jaeseung Lee, Ilsung Cho

SungKyunKwan University

Page 4: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

- Basic Configurations- Current R&D status - Scintillator- SiPM- Simulation- Time schedule- Future plan

Contents

Page 5: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Prototype for EM Calorimeter One Layer : Tungsten 20cm X 20cm X 0.3cm (example) Scintillator 1cm X 20cm X 0.2cm X 20 strips

Total : 30 Layers (~ 26 Xo)

The R&D of prototype includes scintillator, SiPM and DAQ system

Basic Configuration

Tungsten

Scintillator

Page 6: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

1. Survey almost done for the last several monthsScintillator, W/W-Ni(or other alloy), SiPM, Closely collaborate with Japan group• Scintillator:

R&D with Misung Chemical Company Ltd.• Tungsten:

R&D with TaeguTek Ltd• SiPM:

R&D with ETRI

2. SiPM/Tile R&D has been just started

3. Simulation is going on

Current R&D Status

Page 7: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

• The scintillator bars(or strips) for R&D purpose expect to be produced during this semester

• Make sure proper chemical processes

• Compare light yield with commercially available scintillators

• Design of scintillator strip for LC prototype will be underway• Cost

Cast - $40-60 / kg Extrusion - $3.5-7 / kg

Scintillator

Page 8: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Low cost plastic Scintillator

• Extruded plastic scintillator materials - low cost :o Polymer pellets or powder must be used - Commercial polystyrene pellets are available and cheap

- Component: Polystyrene pellets + Dopants(primary & secondary) - Primary dopants : PT, PPO -> 1-1.5% concentration - Secondary dopants: POPOP, bis-MSB -> 0.01-0.03% concentration

- The extrusion process can manufacture any shape

o Some disadvantage - Poor optical quality because of

• the high particulate matter content in the polystyrene pellets • The rapid cool-down cycle leaves the final material stressed.

→ This stress can lead to non-absorptive optical distortions in the material that degrade the attenuation length

o We need more R&D

Page 9: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Extrusion Process(conventional)

Page 10: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Extrusion Process

All the work is done at one facility → reduces costs By removing its exposure to another high temperature cycle → reduces hits history of the product → eliminates an additional chance for scintillator degradation

Page 11: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Scintillator

Extruder

Example of the Extruder

Page 12: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Sample scintillator strip

Sample scintillator

• 10 MINOS tiles will be used for comparison with our scintillator strips which will be produced by the company.

• 10cmX4.1cmX1cm

• For improving light yield

• Cosmic ray and 90Sr will be used

Page 13: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Profile of Scintillator Strip

• All kinds of R&D will be going on while productions.

Misung Chemical Company will produce this type of tile at first.

Page 14: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

•SiPM – Silicon Photo Multiplier

•SiPM is a Russian invention, reported by Boris Dolgoshein and colleagues at Moscow Engineering and Physics Institute, Lebedev Physical Institute, and Pulsar Enterprise (Moscow).

• Ref: NIM A 504 (2003) 48 - 52; NIM A 442 (2000) 187-192

•SiPM consists of ~10**3 micropixels, size ~30microns, with very thin (0.75 micron) high field depletion layer.

What is SiPM ?

Page 15: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

•Pixels are resistively isolated, each working in limited Geiger mode as “binary” devices. The pixels signals are ganged together by aluminum strips and the summed signal is effectively analog, with dynamic range limited by the number of pixels

•Gain ~10**6 Bias voltage ~25V ~ 70V QE < 20%

•Sees single pe, and resolves adjacent many-pe peaks with low noise

•Works In high magnetic fields

•Time resolution ~30ps for 10 pe

How does SiPM work ?

Page 16: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

View of SiPM

• Fabricated at Russia• Dimension : 1mm x 1mm , ~1000 pixels

Page 17: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

View of SiPM

Anode

Kathode

Pixels

Page 18: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

SiPM – measured parameters

Conditions• Yellow LED(595nm)• Wave guide• LED t impulse = 10ns• ADC : LeCroy 2249A Gate = 80ns• Temperature = + 20 ℃

Provided by Prof. K. Kawagoe

Pixel Gain

Efficiency

Dark rate

Page 19: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

SiPM test setup at KNU

Page 20: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Current status for fabrication

• Preparation design and process during this semester - simulation of electric field in Geiger and drift region - wafer and mask - fabracation process R&D

• Try to make sensor chip using FAB facility at ETRI. ETRI : Electronics and Telecommunications Research Institute

Process R&D

• To get parameters : geometrical and chemical parameter s Simulation using TCAD• R&D FAB : 5 ~6 times / year• Packaging , attaching with WLS fiber

Photo sensor – SiPM(Silicon Photomultiplier)

Page 21: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

DAQ system

The proto type has 30 layers(~26 Xo), one layer consists of 20 scintillator bars and tungsten plate the prototype needs 600 read out channels

We have to think of how to manage these channels Probably, VME or CAMAC system are not good solution for beam test for 600 channels.

So, the design of electronics and interface with computer is required.

We are considering R&D of electronics for QDC, TDC and USB2 for interface with computer. need cowork with Japan group

Page 22: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Simulation

Start simulation with different passive absorber configurations

Mokka and susygen 3.0

SUSY simulation under Mokka neutralino pair production from e+e- collision

Simulation of prototype started Tungsten-Scintillator Calorimeter using Geant 4

Page 23: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Simulation of TiCAL prototype

Structure Absorber : 200mm * 200mm * 3mm Scintillator : 200mm * 200mm * 2mm (We simulated plate, not strip yet) 30 layers ( ~26 X0 )

Absorber pure W ( density = 19.3g/cm3) : alloy W-Ni (W:Ni = 95:5) (density=18.7g/cm3) : alloy W-Pb (W:Pb = 90:10) (density=18.5g/ cm3) : alloy W-Pb (W:Pb = 75:25) (density=18.2g/ cm3) : Effective Molier Radius from Simulation W : ~18.9mm W-Ni : ~19mm W-Pb : ~19mm : almost the same

Page 24: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

Energy Resolution

W

Energy(GeV)

%

W-Ni

Energy(GeV)

%

W, W-Alloy or even W-Pb(25%) may be compatible of.

Electron energy = 1, 5, 10, 20, 50, 80, 100, 200 GeV Cut range : 0.001 mm W : (15.14 0.24)/sqrt(E) + (0.217 0.099) W/Ni (Ni 5%) : (15.39 0.20)/sqrt(E) + (0.070 0.084) W/Pb(Pb 10%) : (15.13 0.19)/sqrt(E) + (0.086 0.079) W/Pb(Pb 25%) : (14.89 0.09)/sqrt(E) + (0.149 0.038)

Page 25: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

What to do and Future plan

Producing Extruded scintillator -> 1st prototype in April Fabricating sample of SiPM How to manage DAQ system for prototype Simulation for the thickness of scintillaor = 25 , 30mm Simulation for alloy with different ratio for W:Pb and W:Ni Optimize the ratio of thickness for Absorber and Scin and absorber material. Simulation for scintillator strip Jupiter and Physics simulation Possible target for physics simulation is SUSY - scan the SUSY parameter space - producing generator data in format of HEPEVT Prepare for beam test next year

Page 26: The Status of the Scintillator-based Calorimetry R & D Activities in Korea DongHee Kim Kyungpook National University 3 rd ILC Workshop(Konkuk U.) Apr 1,

검출기 산업체 ( 검출기 )

모든 것이 내수가 가능하다고 사료되며 내수로 돼야 한다는 철학 . R & D 를 통하여 시제품 제작 및 시험을 통한 제작공정을 확립

Scintillator - 압출형 섬광판 – 미성화학 ( 플라스틱회사 )

텅스텐 – TaeguTeK( 전 대한중석 )

Silicon PM, Wafer – 경북대반도체연구소 , 서울대반도체공동연구소 , 센스㈜ , ETRI

Mask 제작 – PKL, 두퐁 , 에스와이테크 , 메디오피아인터네셔널

- 본딩 , PCB, signal cable Readout board (ASIC 포함 ) - Addone 회사