This manual covers the following models 256652/LB 256652/LBT 256652/IDT 256652/TK 256652/TFK User Manual Remote Network Cable Tester TM Pro LANtest LANtest Pro LANtest Pro with tone generator LANtest Pro with tone generator and 4 remote IDs LANtest Pro with 256712A Probe LANtest Pro with 256712F Probe

Upload: others

Post on 27-Dec-2019

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TM LANtest - cablestogo.comLANtest Pro Cable Test Operation 3 5 LANtest Pro T one Generator Operation 3 6 LANtest Pro Remote ID Operation 4 7. Probe Features 4 4 8. Probe Specifications

This manual covers the following models

256652/LB

256652/LBT

256652/IDT

256652/TK

256652/TFK

User Manual

Remote Network Cable Tester

TMProLANtest

LANtest Pro

LANtest Pro with tone generator

LANtest Pro with tone generator and 4 remote IDs

LANtest Pro with 256712A Probe

LANtest Pro with 256712F Probe

Page 2: TM LANtest - cablestogo.comLANtest Pro Cable Test Operation 3 5 LANtest Pro T one Generator Operation 3 6 LANtest Pro Remote ID Operation 4 7. Probe Features 4 4 8. Probe Specifications

Contents Page 1. Introduction 1

2. Features 1 3. 4.

.

.

5

. Product Profile 5 11. Fault Status 8

. Battery Replacement

. Warning

LANtest ProLANtest Pro Specifications 2LANtest Pro Cable Test Operation 3

5 LANtest Pro Tone Generator Operation 3 6 LANtest Pro Remote ID Operation 4 7. Probe Features 4 8. Probe Specifications 9. Probe Operation 510

Introduction Congratulations on your purchase of the LANtest Pro network cable tester series! The LANtest Pro is a small hand-held cable tester, which enables network professionals to quickly and easily verify the integrity of Ethernet twisted pair cables. In one step, the LANtest Pro will test twisted pair cables for open pairs, shorted pairs, reversed pairs, crossed pairs and split pairs. Just push the TEST button, and the LANtest Pro will automatically scan for any existing faults in your cable. The specially designed remote terminator is provided for one-person testing of installed cables. The tone generator function can be used to send a signal through your installed cables which can be traced with the Probe or any cable tracer in the market.

Package Contents:

For 256652/IDT & 256652/LBT Users can buy 256712A or 256712F to Upgrade the tone function

Item Number Remotes Manual Soft carry case Probe Probe with filter256652/LB

256652/LBT

1 Y Y N N

1 Y Y N N

4 Y Y N N

1 Y Y Y N

1 Y Y Y Y

256652/IDT256652/TK256652/TFK

LANtest Pro Features

Tests for wiring faults of open, short, reversed, crossed and split pairs Split pair fault detection at a minimum 40cm cable length Testing of twisted pair cables to over 450ft Tone generator for tracing installed cables and locating faults (available on models 256652/LBT, 256652/TK, 256652/TFK and 256652/IDT) Identification of up to 4 remote termination units (available

1

1123344555899

Page 3: TM LANtest - cablestogo.comLANtest Pro Cable Test Operation 3 5 LANtest Pro T one Generator Operation 3 6 LANtest Pro Remote ID Operation 4 7. Probe Features 4 4 8. Probe Specifications

on model 256652/IDT)Verification of shield integrity Cross talk detection in excess of 3dB + 0.3dB at 3.5Mhz between any two pairs Specially designed remote unit that enables one person to test installed cables Easy to read fault display and high speed testing Debug mode for detailed fault identification results Auto sleep mode and power off switch to decrease power consumption

LANtest Pro Specifications

ConnectorsLANtest Pro Main Unit RJ45 jackRemote Unit RJ45 jack

Pairs tested 1/2, 3/6, 4/5, 7/8 and shield

LED display Horizontal: 5 Green LEDs for pair and shield display (1-2, 3-6, 4-5, 7-8 and shield) TONE G. LED (for models 256652/LBT, 256652/TK,

256652/TFK and 256652/IDT) Vertical: 5 Red LEDs for fault display and #ID display (OPEN, SHORT, REVERSED, MISWIRE,

SPLIT PAIRS and LOW BATTERY) For 256652/IDT the fault display shares with the #ID Display (#1, #2, #3, #4) Cable test length limit Minimum: 0.4m Maximum: Over 200m Power: LANtest Pro: 6V alkaline DC battery Remote identifier: No battery required

Dimensions: LANtest Pro: 125 x 52 x 30 mm (L x W x H) Low battery indicator

LANtest Pro Cable Test Operation:

1.Select "Cable" position on the toggle switch. 2.Plug one end of the subject cable into the RJ45 jack on

the master unit and the other end into the RJ45 jack on the remote terminator.

Note: The remote terminator can be slipped and locked into the master unit for convenient testing of patch cables.

3.Push the test button and check the results: First, check the 5 horizontally aligned green LED indicators (1-2, 3-6, 4-5, 7-8, SHIELD) for integrity status:

Solid light : pair is OKFlashing light : pair is faulty No light : open pair

a. Simultaneously, check the 5 vertically aligned LED indicators (SHORT, REVERSED, MISWIRE, SPLIT PAIRS) for the wiring faults.

b. For more detailed information about what faults are occurring in which pairs, hold the TEST button for 2 seconds to activate "Debug mode." The tester will test each pair one by one, pausing briefly on each pair, and display the corresponding fault status.

LANtest Pro Tone Generator Operation (only available on models 256652/LBT, 256652/TK, 256652/TFK and 256652/IDT): 1. Slide the toggle switch on the LANtest Pro to the "Tone"

position 2. Quickly press the TEST button once for continuous tone

mode, or hold down for two full seconds for warble tone

2 3

Page 4: TM LANtest - cablestogo.comLANtest Pro Cable Test Operation 3 5 LANtest Pro T one Generator Operation 3 6 LANtest Pro Remote ID Operation 4 7. Probe Features 4 4 8. Probe Specifications

mode. To change modes, switch tester off and restart. 3. Using switch on side of Probe, select "speaker mode,"

"LED mode" or "speaker & LED mode." 4. Use the Probe or any cable tracer to trace the subject

wire. Reception of tone will be loudest (amplifier) or brightest (LED) on the subject wire.

LANtest Pro Remote ID Operation (available on model 256656/IDT)

1. Select "Cable" position on the toggle switch. 2. Plug one end of the subject cable into the RJ45 jack on

the master unit and the other end into the RJ45 jack on the remote terminator.

3. Press the TEST button. One of the ID LED's will flash three times. This indicates the number of the remote identification unit attached to the far end of the subject cable. The tester will then automatically continue with the same cable test procedure as the standard LANtest Pro.

Probe Features: Special inductive plastic tip which prevents accidental

shorts (possible with copper-tip tracers) when using near high voltage devices Traces and identifies wires or cable in a bundle or group without damaging cable insulation Adjustable volume level for various work environments

Both amplifier and LED for loud or dark work environments

Can work with any existing tone generator in the market

Probe Specifications:

Pen-style casing Special inductive plastic tip One push-button TRACE switch One battery low LED indicator One amplifier and one LED for signal detection One rotary volume level switch

Probe Operation:

1. With the toggle switch on the side of the Probe unit, select the mode of operation:

a. S & L: Speaker amplifier and LED tracing modeb. Sp. : Speaker only tracing modec. L : LED only tracing mode

2. Press and hold the TRACE button while approaching the subject cable. The intensity of the tone signal will increase as the Probe approaches the cable.

Product Profile

2

14

12

3

LANtestRemote Network Cable Tester

TMPro

16

15

9

13

LANtestRemote Network Cable Tester

ProTM

REVERSED

SPLIT PAIRS

LOW BATTERY

TEST

MISWIRE

SHORT

11

10

1-2 3-6 4-5 7-8 SHIELD

6

8

7

4 5

1

4 5

256652/LB

1. Master port (RJ45) 2. Pair 1 indicator 3. Pair 2 indicator 4. Pair 3 indicator 5. Pair 4 indicator 6. Shield indicator 7. Short faults LED 8. Reversed faults LED 9. Miss wire faults LED10. Split pairs LED11. Battery low indicator12. Test button13. ON/OFF switch14. Battery cover15. Remote unit16. Remote test port (RJ45)

Page 5: TM LANtest - cablestogo.comLANtest Pro Cable Test Operation 3 5 LANtest Pro T one Generator Operation 3 6 LANtest Pro Remote ID Operation 4 7. Probe Features 4 4 8. Probe Specifications

256652/LBT (with tone generator model)

256652/IDT LANtest Pro with tone generator and 4 remote IDs

2

14

1712

3

LANtestRemote Network Cable Tester

TMPro

16

15

9

13

LANtestRemote Network Cable Tester

ProTM

REVERSED

SPLIT PAIRS

LOW BATTERY

TEST

4

MISWIRE

SHORT

2

3

1

11

10

1-2 3-6 4-5 7-8 SHIELD

TONE G. ID

6

8

7

4 5

1

15

1333

12

19

1820

14RemoteTerminator

RemoteTerminator

4Pro

TM

LOW BATTERY

LANtestRemote Network Cable Tester

17

2

RemoteTerminator

2

16 RemoteTerminator

1

7

1

2

3

IDTONE G.

TEST

1-2 3-6 4-5 7-8 SHIELD

SHORT

REVERSED

MISWIRE

4SPLIT PAIRS 11

8

109

14 5

6

256652/TK 256652/LBT with 256712A Probe

256652/TFK 256652/LBT with 256712F Probe (with Filter)

Remote Network Cable TesterLANtest

TMPro12

14

4

17

2

ID

4

3

2

1

TEST

LOW BATTERY

TONE G.

MISWIRE

REVERSED

SHORT

SPLIT PAIRS

3

ProTM

LANtestRemote Network Cable Tester

161-2 3-6 4-5 7-8 SHIELD

9

11

10

13

8

6

5

7

15 1

CABLETRACER

6

4

3

8

7

5

1

2

2 3MISWIRE

14

TRACERCABLE

TM

4

Pro12

17

LOW BATTERY

SPLIT PAIRS

3

Remote Network Cable TesterLANtest

1113

LANtestRemote Network Cable Tester

6

ID

1-2 3-6 4-5 7-8 SHIELD

2

TONE G.

SHORT

16

REVERSEDTEST

98

7

101

15

ProTM

4 5

1

8

3

4

6 7

1

25

NOISE FILTERINCLUDED

6 7

1. Master port (RJ45) 2. Pair 1 indicator 3. Pair 2 indicator 4. Pair 3 indicator 5. Pair 4 indicator 6. Shield indicator 7. Short faults LED 8. Reversed faults LED 9. Miss wire faults LED10. Split pairs LED11. Battery low indicator12. Test button13. ON/OFF switch14. Battery cover15. Remote unit16. Remote test port (RJ45)17. Tone indicator

1. Master port (RJ45) 2. Pair 1 indicator 3. Pair 2 indicator 4. Pair 3 indicator 5. Pair 4 indicator 6. Shield indicator 7. Short faults LED 8. Reversed faults LED 9. Miss wire faults LED10. Split pairs LED11. Battery low indicator12. Test button13. Cable/Tone generator/OFF switch14. Battery cover15. Remote unit #116. Remote unit #217. Remote unit #318. Remote unit #419. Remote test port (RJ45)20. Tone indicator

1. Master port (RJ45) 2. Pair 1 indicator 3. Pair 2 indicator 4. Pair 3 indicator 5. Pair 4 indicator 6. Shield indicator 7. Short faults LED 8. Reversed faults LED 9. Miss wire faults LED10. Split pairs LED11. Battery low indicator12. Test button13. ON/OFF switch14. Battery cover15. Remote unit16. Remote test port (RJ45)

1. Inductive Plastic Tip2. Visible Signal indicator3. Low Battery4. Trace button5. Volume6. Light /Speaker & Light/off switch7. Speaker8. Battery Cover

1. Master port (RJ45) 2. Pair 1 indicator 3. Pair 2 indicator 4. Pair 3 indicator 5. Pair 4 indicator 6. Shield indicator 7. Short faults LED 8. Reversed faults LED 9. Miss wire faults LED10. Split pairs LED11. Battery low indicator12. Test button13. ON/OFF switch14. Battery cover15. Remote unit16. Remote test port (RJ45)

1. Inductive Plastic Tip2. Visible Signal indicator3. Low Battery4. Trace button5. Volume6. Light /Speaker & Light/off switch7. Speaker8. Battery Cover

Page 6: TM LANtest - cablestogo.comLANtest Pro Cable Test Operation 3 5 LANtest Pro T one Generator Operation 3 6 LANtest Pro Remote ID Operation 4 7. Probe Features 4 4 8. Probe Specifications

Fault Status

Short

Open

Reversed

Miss-wire

Split

TEST

SHORT

SPLIT PAIRS

LOW BATTERY

MISWIRE

REVERSED

1-2 3-6 4-5 7-8 SHIELD

63

21

63

12

5

87

45

78

4

55

78

78

3

4

6

21

3

4

6

21

1-2 3-6 4-5 7-8 SHIELD

TEST

SPLIT PAIRS

LOW BATTERY

SHORT

REVERSED

MISWIRE

TEST

SHORT

LOW BATTERY

MISWIRE

SPLIT PAIRS

REVERSED

1-2 3-6 4-5 7-8 SHIELD

63

45

87

63

45

78

21 1

2

5

78

36

45

78

6

4

3

12

12

TEST

SPLIT PAIRS

LOW BATTERY

SHORT

REVERSED

MISWIRE

1-2 3-6 4-5 7-8 SHIELD

8

TEST

SPLIT PAIRS

LOW BATTERY

SHORT

REVERSED

MISWIRE

1-2 3-6 4-5 7-8 SHIELD

5

78

36

45

78

6

4

3

12

12

1-2 3-6 4-5 7-8 SHIELD

TEST

LOW BATTERY

SPLIT PAIRS

SHORT

REVERSED

MISWIRE

Low Battery

Battery Replacement

When the LOW BATTERY light illuminates, the battery does not have sufficient power to support an accurate test. At this time, you must replace it with a new battery.

Battery

Warning 1. Do not connect LANtest Pro to a live circuit as it may

damage the tester and interfere with a live network.2. Testing in a high frequency activated area may cause the

tester to give inaccurate readings.3. Do not drop or get the tester wet as it may cause internal

damage.4. Do not place the tester in areas of high humidity or direct

sunlight.5. Do not open the tester or attempt to repair in case of

malfunction. Please send it back to your distributor for repair or replacement.