SPEctra OPtIa® APHERESIS SYSTEM
Unlocking the Potential of BloodTheraPeUTIC Plasma exChaNge wITh a seCoNdary Plasma devICe
advaNCINg TheraPeUTIC aPheresIs aNd Cell ColleCTIoNs To The NexT level of PaTIeNT Care
Procedural flexibility and reliable performance
By connecting a secondary plasma device* (SPD) to the Spectra Optia system, you can process patients’ plasma through columns, filters and secondary processing systems. In addition to the procedure versatility and reliable performance the Spectra Optia system is known for, the intuitive graphical user interface (GUI) guides you through each step of the procedure.
PrOcEDUrE anD SyStEm hIghLIghtS
Adjustable plasma flow rates Accommodates a range of SPDs*
Automated pressure monitoringProvides you with pressure information for the SPD continuously throughout the procedure
Plasma removal efficiency87% ± 31
Provides an optimized product for secondary processing
Ability to pause the system Gives you flexibility and enables more focused time on the patient and the device
Intuitive controlSimplifies the balance of plasma and replace pumps, regulating the return of treated plasma
Reliable performanceHelps you achieve predictable therapeutic plasma exchange (TPE) results through advanced system technology
*Secondary plasma devices may be used with flow rates from 10 mL/min to 100 mL/min on the Spectra Optia system. Check secondary plasma device specifications for requirements.1Tomey CA, et al., “Improved Plasma Removal Efficiency for Therapeutic Plasma Exchange Using a New Apheresis Platform,” Transfusion 2010, 50(2): 471-477.
how it Works
The GUI guides you through each step of the procedure. The examples below demonstrate the ease of monitoring and controlling the settings throughout procedures.
SEcOnDary PLaSma DEVIcE PrImE
Prompts you to enter both the prime volume and flow rate
Allows you to prime in multiple stages, as required by the SPD
Monitors the build up of pressure to the SPD
maIn rUn ScrEEn
Displays the procedure time
Shows you the treated plasma target flow rate and volumes
Continuously monitors pressure to the SPD
trEatED PLaSma cOntrOL
Fill button automatically adds 25 mL
Arrow buttons allow you to manually adjust the plasma level by any amount
Drain button automatically removes 25 mL
Secondary Plasma Device Gives you the option to connect columns, filters or a secondary processing monitor
ExchangE SEt
Integrated Pressure Sensor Monitors for pressure changes with the SPD and alerts you if attention is needed
horizontal Waste Bagtreated Plasma
BagSaline Bag
cassette
Working with you
Each and every interaction we have with you is important. By fostering open and ongoing relationships, we bring more value to you and the patients we’re all focused on serving.
Even after the technology is in place, we continue to serve you with:
■ Education and training ■ Technical support ■ Clinical and scientific support
■ Customer support ■ Users groups and
professional networks
Low volume tubing set(Maximum ECV* = 185mL) Accommodates smaller patients and supports both patient comfort and safety
Single set, multiple protocols Performs TPE procedures on the same tubing set used for red blood cell exchange
Compact packaging Minimizes the space required for storage
Color-coded components Simplify setup and operation
* Maximum ECV with reservoir filled to high-level sensor (maximum occurs under infrequent alarm conditions)
Not for distribution in the U.S.
©2013 Terumo BCT, Inc. / PN 306610333UnLOcKIng thE POtEntIaL OF BLOOD | tErUmOBct.cOm
Terumo BCT (Asia Pacific) Ltd.
Room 3903-3903A, 39/F ACE Tower, Windsor House 311 Gloucester Road Causeway Bay, Hong Kong
Phone: +852.2283.0700 Fax: +852.2576.1311
terumo Bct Europe n.V.
Europe, Middle East and AfricaIkaroslaan 411930 ZaventemBelgium
Phone: +32.2.715.05.90 Fax: +32.2.721.07.70
terumo Bct, Inc.
10811 West Collins Ave.Lakewood, Colorado 80215-4440USA
USA Phone: 1. 877. 339.4228Phone: +1. 303 . 231.4357Fax: +1. 303 . 542 .5215
terumo Bct Latin america S.a.
La Pampa 1517–12th FloorC1428D2EBuenos Aires Argentina
Phone: +54.11.5530.5200 Fax: +54.11.5530.5201
terumo Bct Japan, Inc.
Ebisu South One Bldg. 9F 1-7-8, Ebisu-minami, Shibuya-ku Tokyo 150-0022Japan
Phone: +81.3.6743.7890Fax: +81.3.6743.9800