uncertainty evaluation of stack flowrate measurement with ...flomeko2019.lnec.pt/proceedings/1058...

28
Uncertainty Evaluation of Stack Flowrate Measurement with S-Type Pitot Tube by Monte Carlo Method Doan Trang Nguyen 1 , Kang Woong 2 , Saeng Hee Lee 2 , Yong Moon Choi 2 1 University of Science and Technology 2 Korea Research Institute of Standards and Science

Upload: others

Post on 28-May-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty Evaluation of Stack Flowrate Measurement with S-Type Pitot Tube by Monte

Carlo Method

Doan Trang Nguyen1, Kang Woong2, Saeng Hee Lee2, Yong Moon Choi21University of Science and Technology

2Korea Research Institute of Standards and Science

Page 2: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Contents

Introduction

On-site measurement with S-type Pitot tube

Uncertainty evaluation

Conclusions

Page 3: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

2

The Greenhouse EffectUNFCCC(UN Framework Convention

on Climate Change), 1994Kyoto Protocol, 1997

Energy and Industry → 95% of GHGs emission in KOREA

Energy 84% Industry 11%Others 5%

N2O CO2 CH4 HFCs

Needs of accurate and reliable measurement and estimation

GHGs emissions

Proper Uncertainty Analysis

Greenhouse Gas Emission

Top 10 countries increase GHGs 2017

“30% reduction of GHGs until 2020”KOREA GHG Emission Trading Scheme

Since Jan 2015

(BP Statistical review of World energy June

2018)

Page 4: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Methodology for estimating GHG emission

Continuous emission

measurement

(Tier 4)

Fuel consumption (Tier 1)

by IPCC guidelines, EPA

� � �� � �� � �� � ��� � ��

E : estimated emission (kg)FC : fuel consumption (TJ)EF : emission factor (kg/TJ)FM : fuel mass (kg)NCV : net calorific value(TJ/kg)

Carbon content (Tier 3)

by IPCC guidelines, EPA

� � �� � �� ���

CC : fuel carbon content(kg/kg)MCO2 : molecular mass of carbon dioxideMC : atomic mass of carbon

Page 5: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Methodology for estimating GHG emission

Continuous emission measurement (Tier 4)

by IPCC guidelines, EPA

� � ∑ �����,����� �∑ ������,� � �����,� �

���

���� �

E5min,i : 5-min accumulated emission of ith measurement (kg)x5min,i : 5-min averaged concentration of the ith measurement(% or ppm)Q5min,i : 5-min accumulated volumetric flow of the ith measurement (m3)Mgas : molar mass of an emission gas, MV is the molar volume of ideal gasN : total number of 5-min estimated emissions.

CEMS

Sample Interface

Pollutant Analyzer

Flow rate Monitor

Data Recorder

Page 6: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Measurement of the flow rate in stacks

� Equation for The 5-min accumulated volumetric flow rate

����� � �� � !"

4�

$%

760�273.15

.%� 1 / �0 � t

Q5min : dry volumetric flowrate at stack (m3/min)23: average velocity (m/min)D : diameter of the stackTs : average temperature of the stack gas (K)Ps : average absolute pressure of the stack gas (mmHg)Xw : water content of the stack gas (%)

� Methods

U.S. EPA Method 2: Determination of Stack Gas Velocity and Volumetric Flow Rate

U.S. EPA Method 4: Determination of Moisture Content in Stack Gases

Korea Ministry of Environment ES. 01809.1: Test Method on air pollution

Estimating Uncertainties of

Stack Gas Flow rate measurement for

CEM by GUM and MCM

Estimating Uncertainties of

Stack Gas Flow rate measurement for

CEM by GUM and MCM

Page 7: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

On-site measurement with S-type Pitot

Instruments for measuring velocity in stacks in KoreaInstruments for measuring velocity in stacks in Korea

Page 8: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

On-site measurement with S-type Pitot

S-type Pitot tubeS-type Pitot tube

S Pitot tube

Standard

Pitot

�% � �4 �"∆4

6

�%: flow velocity in the stack gas(m/s)

CP : S type Pitot tube coefficient

∆P : differential pressure between impact and wake orifice (Pa)

ρ : density of the stack gas (kg/m3)

- Structure follows: ISO 10780, KS M9429, EPA Title

40: Part 60, Appendix A method2

- Large pressure orifices(Φ=5~10mm) & Strong tubes

for high dust environments

- Measurement differential pressure between an impact

and wake orifice based on Bernoulli equation

Characteristics of S-type Pitot

Page 9: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

On-site measurement with S-type Pitot

Sampling traverse points in the stack for velocity distribution by ISO 10780 / EPA method 1

Page 10: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

On-site measurement with S-type Pitot

Combined heat and power plan at Gunjang Energy Co., Ltd

CFBC 200 ton/hrTurbine 360 MW

Page 11: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

On-site measurement with S-type Pitot

NOx, SO2, O2

Concentration

Flow rate

Temperature

Total Suspended Particle

Analyzer Control UnitOn-site Measurement

Tele-metering system(TMS) Local Area Network

Internet / CDMAEnvironment Agency

Stack emission

Page 12: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation

Modelling for dry volumetric in the stack Modelling for dry volumetric in the stack

����� � �4 �2∆$

7� !"

4�

$%

760�273.15

.� 1 / �0 � 300

)X1(uc)P(uc)T(uc

)D(uc)ρ(uc)P∆(uc)C(uc)Q(u

w22

)wX1(s22

sPs22

sT

22D

22ρ

22P∆p

22pC

2c

--+++

+++=

GUM method

ISO/IEC Guide 98-3: Guide to the Expression of Uncertainty in Measurement

Law of Propagation of Uncertainty through Taylor series approximation

Page 13: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Sensitivity coefficientSensitivity coefficient

ws

std

std

sPD

ws

std

std

s23Pρ

ws

std

std

s2PP∆

ws

std

std

s2

ppC

)X1(T

T

P

PD

2

π

ρ

P∆2C

D

QC

)X1(T

T

P

PD

4

π

ρ

P∆2C

2

1

ρ

QC

)X1(T

T

P

PD

4

π

P∆ρ

2C

2

1

P∆

QC

)X1(T

T

P

PD

4

π

ρ

P∆2

C

QC

×××××==

×××××==

×××××==

×××××==

-∂

-∂

-∂

-∂

2s

std

std

2P

w)wX1(

w2s

std

std

2P

ssT

ws

std

std

2P

ssP

T

T

P

PD

4

π

ρ

P∆2C

)X1(

QC

)X1(T

T

P

PD

4

π

ρ

P∆2C

T

QC

)X1(T

T

P

1D

4

π

ρ

P∆2C

P

QC

××××==

×××××==

×××××==

--∂

--∂

-∂

-

Relative uncertaintyRelative uncertainty

2w

w2

2s

s2

2s

s2

2

2

2

2

2

2

2P

p22

c

)X1(

)X1(u

T

)T(u

P

)P(u

D

)D(u4

ρ

)ρ(u

4

1

P∆

)P∆(u

4

1

C

)C(u

Q

)Q(u

-

-+++

+++=

Page 14: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

2P

p2

C

)C(u

S-type Pitot tube coefficient and uncertainty are determined by calibration certification

S-type Pitot tube was calibrated in the wind tunnel of the accredited calibration laboratories

- Korea Environment Corporation ( U = 1.1 %, k = 2 with 95% confidence level )

Uncertainty Component

ValueStandard

uncertaintyui (%)

Probabilitydistribution

SensitivityCoefficient

ci

UncertaintyContribution to u(Q)

ui x ci (%)

Type A0.826

N/A - 1 -

Type B 0.55% Normal 1 0.55 %

Uncertainty evaluation by GUM

S-type Pitot Coefficient (�8�S-type Pitot Coefficient (�8�

Page 15: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Type A - collective data every 3 seconds for 5 minutes

Type B – annual variation of linearity results in the performance test between 2009 & 2010

Uncertainty Component Value

Standard uncertainty

ui (%)

Probabilitydistribution

SensitivityCoefficient

UncertaintyContributionui x ci (%)

Type A136.4 Pa

0.54% Normal 1/2 0.27 %

Type B 1.78 % Rectangular 1/2 0.89 %

Different pressure (∆$�Different pressure (∆$�P∆

)P∆(u2

Page 16: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Gas density (ρ)Gas density (ρ)

Weighted average based on concentration of major gas components (N2 , CO2, O2, Ar, Water)

Type A - collective data every 10 seconds for 5 minutes

Type B - difference between calculating gas density value and used theoretical value ( 1.3 kg/m3

by test method in environment ministry

Uncertainty Component Value

Standard uncertainty

ui (%)

Probabilitydistribution

SensitivityCoefficient

UncertaintyContributionui x ci (%)

Type A1.33 kg/m3

0.0054 % Normal 1/2 0.0027 %

Type B 1.12 % Rectangular 1/2 0.61 %

4.22

100)18X%28N%94.39Ar%32O%44CO(%ρ

w2220

××+×+×+×+×=

std

s

s

std0std P

P

T

Tρρ ××=

ρ

)ρ(u2

Page 17: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Stack diameter (!�Stack diameter (!�

The manufacture’s technical specification with the value 2500 mm

The resolution of tape measure tool ± 10 mm

Uncertainty Component Value

Standard uncertainty

ui (%)

Probabilitydistribution

SensitivityCoefficient

UncertaintyContributionui x ci (%)

Type A2500 mm

N/A - 2 -

Type B 0.23 % Rectangular 2 0.46%

D

)D(u2

Page 18: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Static pressure ($%�Static pressure ($%�

Uncertainty Component Value

Standard uncertainty

ui (%)

Probabilitydistribution

SensitivityCoefficient

UncertaintyContributionui x ci (%)

Type A756

mmHg

0.0019 % Normal 1 0.0019 %

Type B 0.13 % Rectangular 1 0.15 %

Type A - collective data every 3 seconds for 5 minutes

Type B - below 1 mmHg from calibration certificates

s

s2

P

)P(uTemperature (.%�Temperature (.%�

s

s2

T

)T(u

Type A - collective data every 3 seconds for 5 minutes

Type B - below 1 K from calibration certificates

Uncertainty Component Value

Standard uncertainty

ui (%)

Probabilitydistribution

SensitivityCoefficient

UncertaintyContributionui x ci (%)

Type A

409 K

0.0048 % Normal 1 0.0048 %

Type B 0.14 % Rectangular 1 0.14 %

Page 19: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Water content (90�Water content (90�)X1(

)X1(u

w

w2

-

-

EPA method 4 (Determination of moisture content in stack), Test method in Korea Environ.

Water content is calculated by condensed moisture in the impinger and volume flow rate in the dry gas meter

18

m

4.22

P

P

T

TV

4.22

1)

P

P

T

TV

P

P(

18

m

X

astd

m

m

stdm

std

m

m

stdm

std

wa

w

+

××

××××+

=

ma : increment mass of water, (g/min)Pw : water vapor pressure (mmHg)Vm : dry gas volume by gas meter (L/min)Pm : pressure at gas meter (mmHg)Tm : temperature at gas meter (K)

Page 20: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Type A - continuous moisture mass measurement method (0.292 g/min ) in every 10 seconds

Type B - difference between measured water content value and used theoretical value ( 8.1%)

- estimated by numerical derivative method (GUM) in water content equation

Uncertainty Component Value

Standard uncertainty

ui (%)

Probabilitydistribution

SensitivityCoefficient

UncertaintyContributionui x ci (%)

Type A91. 5%

0.0016 % Normal 1 0.0016 %

Type B 0.30 % Rectangular 1 0.30 %

Page 21: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Velocity distribution (∆��Velocity distribution (∆�� )V∆(u

Velocities at 10 sampling traverse points were measured according to EPA method 1& Test method

S-type Pitot tube in the stack is typically fixed in a certain position

Type B - Deviation of averaged velocity by velocity distribution with velocity at fixed position in the cross section of stack

Uncertainty Component Value

Standard uncertainty

ui (%)

Probabilitydistribution

SensitivityCoefficient

UncertaintyContribution

ui (%)

Type A14.8 m/s

Type B 1.54 % 1 1.54 %

Page 22: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by GUM

Uncertainty BudgetUncertainty Budget

Symbol Value unitUncertainty component Sensitivity

coefficient

CombineduncertaintycontributionType A % Type B %

Cp 0.826 - - 0.55 1 0.55 %

∆P 136.4 Pa 0.54 1.78 0.5 0.93 %

ρ 1.33 kg/m3 0.0054 1.12 0.5 0.56 %

D 2500 mm - 0.23 2 0.46 %

Ps 756 mmHg 0.0019 0.15 1 0.15 %

Ts 409 K 0.0048 0.16 1 0.16 %

1-Xw 91.5 % 0.0016 0.30 1 0.30 %

∆VD 14.8 m/s 1.54 - 1 1.54 %

Q 12972.5 m3/min (5min)

Combined uncertainty of the flow rate measurement 2.05 %

95 % confidence level, k= 2

Expanded Uncertainty, U = 4.1 %

Page 23: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by MCM

Sources of measurement uncertainty contributions Sources of measurement uncertainty contributions

Page 24: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by MCM

Sources of measurement uncertainty contributions Sources of measurement uncertainty contributions

Propagation of a joint probability distribution

Outcome is a set of trials from the probability

distribution associated with the measurand

Parameter input Magnitude Unit Distribution

Concentration of CO2, %�;" 9� � 15.24 % t-distribution

Gas analyzer for CO2 9" � 0 % Gauss

Concentration of O2, %;" 9< � 4.028 % t-distribution

Gas analyzer for O2 9> � 0 % Gauss

Dry gas volume, �� 9� � 4.61 L/min t-distribution

Dry gas meter 9? � 0 L/min Gauss

Mass of moisture, @A 9B � 16.456 g Rectangular

Mass of moisture, @���� 9C � 17.981 g Rectangular

Sampling time, DA 9E � 0.1 min Rectangular

Sampling time, D���� 9�A � 0 min Rectangular

Pressure in stack, $% 9�� � 756 mmHg t-distribution

Pressure gauge 9�" � 0 mmHg Rectangular

Temperature in stack, .% 9�< � 409 K t-distribution

Temperature device 9�> � 0 K Rectangular

Deviation of density, ∆7 9�� � 0 kg/m3 Rectangular

Different pressure, ∆$ 9�? � 136.4 Pa Gauss

Different pressure gauge 9�B � 0 Pa Gauss

Temperature at meter, .� 9�C � 297.75 K Rectangular

Pressure at meter, $� 9�E � 771 mmHg Rectangular

Water vapor pressure, $0 9"A � 5.69 mmHg Rectangular

Calibration of S-type Pitot, �4 9"� � 0.826 Gauss

Diameter of stack, ! 9"" � 2.5 m Rectangular

Velocity distribution, ∆� 9"< � 0 m/s Rectangular

Deviation of moisture, ∆90 9"> � 0 % Rectangular

Page 25: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Uncertainty evaluation by MCM

Number of Monte Carlo runs Number of Monte Carlo runs

The Monte Carlo simulation process carried by number of Monte Carlo trials (M)

M number decides shape of probability density function for the dry flow rate

In this study the number of model evaluations simulated respectively M = 105, 106, and 107

0

20000

40000

60000

80000

100000

120000

140000

11922,132 12447,199 12972,266 13497,334 14022,401

M = 106

0

1000

2000

3000

4000

5000

11925,969 12449,279 12972,589 13495,9 14019,21

M = 105

0

100000

200000

300000

400000

500000

11922,386 12447,332 12972,278 13497,224

M = 107

Page 26: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Monte Carlo simulation

Framework of this simulation was based on the Microsoft Excel and Microsoft Visual Basic for

Page 27: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube

Conclusion

1. Uncertainty Evaluation Result

By GUM method:

Q(every 5 minutes) = 12972.7 m3

U(Q) = 4.1 % with k = 2, P = 95 %

By Monte Carlo method:

Q(every 5 minutes) = 12972.2 m3

U(Q) = 4.0% (525.2 m3) with k = 2, P = 95 %

� Agreement between two methods

� Reliable to use the Monte Carlo method in a

complicate mathematical model

2. The main components affect the dry flow rate measurement

� ∆�, ∆$, ∆7, �4 : contribute dominantly to the uncertainty of the

dry flow rate measurement

Page 28: Uncertainty Evaluation of Stack Flowrate Measurement with ...flomeko2019.lnec.pt/proceedings/1058 Doan Trang Nguyen.pdf · On-site measurement with S-type Pitot S-type Pitot tube