Blue Sky Blue Bl Vallox AIR DISTRIBUTION SYSTEM Technical instructions Planning and installation instructions ning and installation ctions Vallox BlueSky is a flexible, sound attenuating and installation-friendly piping system for ventilation. Speedy installation and the almost non-existent need for duct components make the Vallox BlueSky duct an affordable solution for both new building and renovation. - outer diameter 75 mm - can be fully installed in warm rooms without large enclosures - M1 classification - smooth inner surface – small flow resistance when installed in blown wool insulation - flexible duct already at the stage when the building frame is being made, in the same way as electricity and sewage installations.

Upload: lecong

Post on 29-Mar-2018

233 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

BlueSkyBlueBlueVallox

AIR DISTRIBUTION SYSTEMTechnical instructions Planning and installationinstructionsPlanning and installationinstructions

Vallox BlueSky is a fl exible, sound attenuating and installation-friendly piping system for ventilation.

Speedy installation and the almost non-existent need for duct components make the Vallox BlueSky duct an affordable solution for both new building and renovation.

- outer diameter 75 mm- can be fully installed in warm rooms without large enclosures

- M1 classifi cation

- smooth inner surface – small fl ow resistance

when installed in blown wool insulation

- fl exible duct

already at the stage when the building frame is being made, in the same way as electricity and sewage installations.

Page 2: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

2

BlueSkyBlueBlueVallox

- air distribution system

which is easy to clean.

unit and the air distribution box.

TECHNICAL DATA

2

sound-insulated air distribution box. Because the air fl ow

natural basic adjustment. It is extremely easy to measure

Flexible and installation-friendly piping system for ventilation

Page 3: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

3

BlueSkyBlueBlueVallox

- air distribution system

Recommendation:

recommended.

Pressure loss is then 45 Pa.

Flow speed Air volume Flow resistance

m/s m3/h l/s Pa/m

pPa/m

2 4 5 8 10 20 30 40

1,8

1,6

1,6

1,21,11,00,90,80,70,60,50,40,30,20,1

2,8 5,6

m3/h

l/s8,3

pPa/m

10987654321

2 4 5 8 10 20 30 40

2,8 5,6 8,3

m3/h

l/s

Pressure loss in Vallox BlueSky duct

3

3

Dimensioning of extract and supply air ducts Pressure loss

in Vallox BlueSky 90° bend

VALVE OUTLETS Depending on air fl ow, the use of one or two ducts leads to a natural basic adjustment and facilitates the fi nal measurement of air fl ows.

Pipe diameter: Outer ø 75 mm, inner ø 63 mm, A = 0.0031 m2

Page 4: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

Example of pressure loss in supply air ductwork to the farthest bedroom 8 l/s

Example of pressure loss in extract air ductwork from washroom 10 l/s

Total 44 Pa

4

3

3

3

LIVING ROOM

WALK-IN CLOSET

DV

DV

DV

DV

DV

DV

DV

DV

BEDROOM

BEDROOM

HALL

COLD-STORAGE ROOM WC

KITCHEN

ENTRANCE TAMBOUR

WOOD STORAGE ROOM

CHANGING ROOM

WASHING ROOM

SAUNA

Cooker hood 0 (-20)

KTS 125 +6 above sauna stove

Extraction to the roofLPV Ø 160 Vilpe

Vallox 110 MV

KSO 125- 6

KSO 125-10

TINO-D+8

TINO-D+8

TINO-D+9

TINO-D+12

TINOi-D-10

TINOi-D-3

TINOi-D-8

ø 160

ø 160

KSO 125-10

Ducts from distribution boxes onward ø 75/63

SUSPENDED ENCLOSURE 200 mmSUSPENDED ENCLOSURE 100 mmCARBON DIOXIDE SENSOR HUMIDITY SENSORSILENCER

BEDROOM

PLANNING OF BlueSky VENTILATION SYSTEM

BlueSkyBlueBlueVallox

- air distribution system

Renovation house

Pressure loss

Page 5: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

Duct volume

Calculation for valve coupling units

Other ducts

BlueSky supplies

5

3

3

3

LIVING ROOM

WALK-IN CLOSET

DV

DV

DV

DV

DV

DV

DV

DV

BEDROOM

BEDROOM

HALL

COLD-STORAGE ROOM WC

KITCHEN

ENTRANCE TAMBOUR

WOOD STORAGE ROOM

CHANGING ROOM

WASHING ROOM

SAUNA

Cooker hood 0 (-20)

KTS 125 +6 above sauna stove

Extraction to the roofLPV Ø 160 Vilpe

Vallox 110 MV

KSO 125- 6

KSO 125-10

TINO-D+8

TINO-D+8

TINO-D+9

TINO-D+12

TINOi-D-10

TINOi-D-3

TINOi-D-8

ø 160

ø 160

KSO 125-10

Ducts from distribution boxes onward ø 75/63

SUSPENDED ENCLOSURE 200 mmSUSPENDED ENCLOSURE 100 mmCARBON DIOXIDE SENSOR HUMIDITY SENSORSILENCER

BEDROOM

DIMENSIONINGVallox 110 MV R

SUPPLIES

1

roll44

4

41

11

m5

List of suppliesVallox 110 MV R

InsulationSupply and extract air ducts do not need insulation below the vapour barrier. Outdoor and exhaust air ducts are insulated below the vapour barrier with 19-mm cellular plastic and above the vapour barrier with 50-mm wool (no vapour-proof surface).

Indicative calculation of supplies for BlueSky air distribution system

BlueSkyBlueBlueVallox

- air distribution system

DV = Door vent:Rooms to which 15...20 mm of air is broughtRooms from which circa 10 mm of air is extracted20 mm in the door between the door of the bathroom next to the sauna and the dwelling

Page 6: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

6

Ducts and parts

Outer connector for BlueSky duct.

10 pcs/bag.

Flexible ventilation duct.- roll 50 running metres- outer ø 75 mm- inner ø 63 mm

BlueSkyBlueBlueVallox

- air distribution system

150

- duct outer ø 75 mm

Duct size, ø125 mm.Air volume 17 l/s 8 Pa.Pipe outlets 2 x 75 mm. Stop plug.

Duct size, ø125 mm. Air volume 17 l/s 4/6 Pa.Pipe outlets 2 x 75 mm. Stop plug.

78

78

100 180

1005080

DN 125

L280

Vallox BlueSky 75/63 PIPE

WASHER RING FOR PIPE 75 mm Dimensions

BEND 90° 75 mm Dimensions

CONNECTION PART FOR VALVE / BACK CONNECTION Dimensions

OUTER CONNECTOR 75 mm Dimensions

CONNECTION PART FOR VALVE/SIDE CONNECTION Dimensions

ø 75

Galvanised steel sheet.For narrow places where the bending radius of BlueSky pipe is not enough.

200 100 50

12578 15

060

d d

200 mm

50 50100

150 mm60

Page 7: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

7

Supply and extract air valves

needed.

59

90

ø80

50

nim

.

42

ø12mm

255

150

90

59

ø3,3 mm

150

255 50 42

nim

.ø80

BlueSkyBlueBlueVallox

- air distribution system

SUPPLY AIR VALVE TINO-D

EXTRACT AIR VALVE TINOi-D

ADJUSTMENT OF Tino VALVES

Dimensions

Dimensions

Adjustment values

Adjustment values

- Supply air valve with two BlueSky duct joints- Valve meets the choke requirement for fi re valves (42 l/s/100 Pa)

- Extract air valve with two BlueSky duct joints- Valve meets the choke requirement for fi re valves (42 l/s/100 Pa)

Tino-D supply air valve

Tinoi-D extract air valve

TINO-D k

A 4.5

closed rows

4

8

TINOi-D k

A

closed rows

4

8

Page 8: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

8

Air distribution boxes

Silencing, BlueSky air distribution box

BlueSky AIR DISTRIBUTION BOX 15, H = 300 Dimensions Air volumes

002

400 300

78

125

BlueSkyBlueBlueVallox

- air distribution system

Connection 160 mm

Connection 125 mm

H = 160

H = 200

Connection 200 mm

17 1715

15 outlets, dB 17 17

BlueSky AIR DISTRIBUTION BOX 6, H = 160/ H = 200 Dimensions Air volumes

BlueSky AIR DISTRIBUTION BOX 10, H = 200 Dimensions Air volumes

500 530

160

78

125

500 500

200

160 78

600

300

500

78

200

Page 9: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

9

BlueSkyBlueBlueVallox

- air distribution system

10 pcs/bag

OUTLET COLLAR 75 mm + 2 locking devices

PLUG AND SEAL FOR 75 mm OUTLET COLLAR

LOCKING DEVICE

COVER FOR DISTRIBUTION BOX 75 mm

Dimensions

Dimensions

Dimensions

Dimensions

78

96

65

Accessories for air distribution boxes

96

78

38 mm

Page 10: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

10

the ceiling.

installation!

INSTALLATION OF BlueSky AIR DISTRIBUTION SYSTEM

Installation in suspended enclosures or casings

no heat insulation is needed. If

insulation against condensation in the duct is necessary.

Attic fl oor installation

insulation, it is recommended to do

insulation for the attic fl oor insulation is enough for insulating the duct as well.

are insulated.

to be met.

VTT.

Fire protection and enclosure

ducts are enclosed with material of at least class

Supporting

all joints and on both sides of the connector outlet. There

Installation tips Installation regulations

BlueSkyBlueBlueVallox

- air distribution system

Page 11: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

6

5

4

3

2

1

11

Intermediate fl oor installation 1. Floor coating2. Timber panel or plasterboard3. Vallox BlueSky pipe in insulation4. Ceiling below

Installation in concrete pouring

reinforcement or thin-shell slab and fi xed to the concrete reinforcement with cable ties. After the duct and other

the sound of the fan.

installation corners and their screws.

there is an outlet collar with a rubber ring.

after which one or more ducts can be connected to it.

tongues.

duct outlet.

duct outlet.

Installation of air distribution boxes and valve connection parts

1. Floor coating2. Cement mortar3. Building foil4. Soundproofi ng as required5. Concrete slab according to strength calculations, inside which the Vallox BlueSky pipes have been cast.6. Vallox BlueSky ventilation ductwork

BlueSkyBlueBlueVallox

- air distribution system

1

2

3

4

Page 12: Vallox Blue - visthus.isvisthus.is/wp-content/uploads/2016/07/2610-Info-Hekatherm-Vallox... · for duct components make the Vallox BlueSky duct an ... 5SBOTWFSTF QSPm MF SJHJEJUZ43

hot attic in summer.

Insulation of BlueSky ducts on fl oors and in cold rooms

other insulation than blown wool when the duct is installed

12

Vallox oy

BlueSkyBlueBlueVallox

- air distribution system

unit

Ducts in cold and warm roomsNote!The outdoor and exhaust air duct must not be installed inside attic insulation

Ducts in warm rooms – interior

Ducts in cold rooms– in the attic, attic insulation and above

Attic insulation

Attic insulation

Vapour barrier

Vapour barrier

DUCTS IN BLOWN WOOL

Vapour barrier

Vapour barrier

ROOF TRUSS

No insulation