Value through maximized performance:
High-throughput (3 ports) instrument capable of krypton low surface area measurement and micropore analyses Advanced interactive MicroActive 2.0 software with user
defined reports Small bench top footprint with easy access to connections Upgradeable mesopore to micropore ports include
dedicated 10 and 0.1 torr transducers Very High Quality (VHQ) manifold construction provides
negligible outgas rates for high quality micropore information especially in low relative pressure region
Heated vapor analysis standard. Extended vapor range
option is available
Capabilities Adsorption and desorption isotherms
Cumulative mesopore volume and distribution by BJH
Pore Diameter (Å)50 100 500 1,000
Por
e V
olum
e (c
m³/g
)
0.00.0
0.2
0.4
0.6
dV/dlog(D
) Pore V
olume (cm
³/g)
0.00.0
0.5
1.0
1.5
Volume
Relative Pressure (P/Po)10-6 10-5 10-4 10-3 10-2 10-1 100
Qua
ntity
Ads
orbe
d (c
m³/g
STP
)
00
50
100
150
Ar @ 87K sorption on ZSM-5 zeolite
N2 @ 77.3K sorption on silica-alumina extrudates
BET Surface Area Report BET Surface Area: 0.1316 ± 0.0016 m²/g Slope: 41.639453 ± 0.509917 g/cm³ STP Y-Intercept: 1.253512 ± 0.097961 g/cm³ STP C: 34.218231 Qm: 0.0233 cm³/g STP Correlation Coefficient: 0.9994755 Molecular Cross-Sectional Area: 0.2100 nm² )
(BET surface area
Kr @ 77.3K sorption on gelatin excipient
Pore Width (Å)00 1 2 3 4 5 6 7 8 9 10 11 12
Por
e V
olum
e (c
m³/g
)
0.000.00
0.05
0.10
0.15
dV/dw
(cm³/g·Å
)
0.000.00
0.05
0.10
Horvath-Kawazoe Cumulative Pore Volume Plot
Cumulative micropore volume and distribution
N2 @ 77.3K sorption on Y zeolite
Increased Range with Accurate, Robust, Reproducible Results Class leading proprietary engineering and precise temperature control secure excellent reproducibility from port to port. This ensures confident, accurate, rugged and reliable results in high throughput analyses.
Outstanding micropore performance
Pore Size Distribution of Three 13X Zeolite Samples Analyzed Simultaneously The increased range of
resolution permits data collection at very low pressures, where micropores begin to fill. Enhanced dosing options allow for a detailed isotherm to be collected over the entire range of relative pressure.
Extended resolution in micropore region of better than 10-8 relative pressure (P/Po)
Three analysis ports with independent transducers permit concurrent or dissimilar samples on each ports
Po port with a dedicated transducer
Interactive, data reduction and user-defined report options with new MicroActive 2.0 software
25 bit A/D conversion of pressure transducers secures maximum data resolution Stainless-steel gas inlet
and analysis manifold
Pneumatically actuated, hard seal valves provide ultra-clean operation
Outstanding gas management; Measured outgas rate is <0.03 µmHg/min. Four instruments may
be operated from one computer
Redesigned dewar can provide >80 hours of unattended operation
Four Free-Space Modes - Entered, Measured, Measured Post Analysis, and Calculated
Competitor B Competitor Q 3Flex
Transducers 11 7 12
Transducer (temperature controlled)
2 (manufacturer)
2 (manufacturer)
12 (proprietary Micromeritics)
Vacuum gauge Dual gauge Dual gauge Dual gauge
Manifold (temperature controlled)
40°C optional 45°C (proprietary Micromeritics)
Data acquisition A/D
24 bit 24 bit 25 bit (29 bit a/d)
Dosing & Evacuation Needle valves Needle valves Servo
Hybrid turbo pump Elastomer seal CF (metal seal)
CF (metal seal)
Roughing pump 2 stage diaphragm 2 stage diaphragm 4 stage diaphragm
3Flex Hardware Specifications Comparison
With you, the user in mind…
Training videos within the 3Flex software will guide new users through the analysis step-by-step. Sections include how to:
• Prepare samples • Create sample files • Create parameter files • Connect gases
With you, the user in mind… Method wizards provide guided assistance to create methods for novice or experienced users.
With you, the user in mind…
Method wizards include guided assistance for the
creation of methods in accordance with the ASTM
With you, the user in mind… Improved system control within MicroActive 2.0 provides the capability to alternate between pressure tables and the dosing routine.
This improved control gives the user the ability to change the pressure increment, volume dose increment, and equilibration interval time between data points and during analysis for pressure points yet not reached. This permits a higher level of accurate dosing of very low partial pressures resulting in improved resolution in the isotherm data.
The 3Flex library includes more than 30 fluids
• Inorganic gases: nitrogen, oxygen, argon, krypton
• Alkanes: methane, ethane, propane, butane
• Alkenes: ethylene, propylene The 3Flex is designed with extensive chemical compatibility
• The large library allows the user to utilize the full instrument capabilities
Reduce the “user effort” to find information
• Do more faster
With you, the user in mind…
Standard Adsorptive properties included with 3Flex:
With you, the user in mind… Mercury Intrusion Data Overlay
MicroActive 2.0 for 3Flex includes a powerful utility for including the pore size distribution from mercury porosimetry analyses with pore size distributions calculated from gas adsorption isotherms. This new import function allows users to rapidly view micro, meso, and macro pore size distributions in one easy-to-use application.
Alumina -Mercury Intrusion
Alumina -BJH Desorption Pore Volume
With you, the user in mind… The 3Flex features preventive/maintenance alerts, diagnostic monitoring, and trouble shooting embedded in its software.
The Dashboard provides continuous information on key
operational parameters, as well as preventative maintenance cycles
The instrument log monitors system activity and records events. In case of a problem,
you can view the log to see all events and where a failure
may have occurred.
Reduces Operating Costs and Maximizes Return on Your Investment The versatile nature of the 3Flex permits high-throughput, multiple macropore ( >330nm) to micropore analyses from one optimized instrument. Up to four units can be run from one computer, allowing a user to analyze up to 12 samples. Independent transducers at each port permit concurrent or different sample analyses to be run, saving time by providing superior throughput.
Improved Analytical Performance Hard seals provide virtually leak-free outgas rate operation for accurate dosing and gas delivery. Increased resolution in lower relative pressures improve data collection for micropore analysis. Improved utility in dosing and pressure table routines permits accurate dosing in small increment control. 25 bit A/D conversion provides maximum resolution.
Value and Effective Use of Personnel A long-life dewar allows complete adsorption and desorption isotherms to be collected without operator intervention. Long micropore analyses can be performed with minimal user involvement. MicroActive software allows users to interactively evaluate isotherm data. Users can easily include or exclude data, fitting the desired range of experimentally acquired data points. The User-Defined Report Options editor will allow the user to define multiple reports, perform custom calculations, transform plots, and display tabular data. Available training videos embedded in the software permit new users to be trained quickly.
Operating System Diagram monitor turbo pump performance in real time
dosing and evacuation servo to decrease analysis time
degas / vapor heating mantle display
Cold cathode gauge to monitor high vacuum levels
Temperature-controlled manifold at 45oC
Specification
3Flex Instrument component
Specifications
3Flex Analysis Performance
Specifications Discussion
Sample Analysis Ports
3 ports 2 or 3 micropore
capable ports High-throughput mesopore to micropore capability, ability to
upgrade mesopore ports to micropore
Pump
Turbo molecular drag pump in series with
four stage diaphragm pump
Two pumps ensure best performance in high vacuum systems, one to pull pressure down to level where high pressure vacuum
pump has optimal initial performance
Pumping Speed (Hydrogen)
53/L sec 53L/sec High pumping speed is essential to permit fast and clean
evacuation
Ultimate Vacuum 3.75 x 10—9 mm Hg 1.0 x 10-5 mm Hg (@ sample port)
Determines the quality and speed of analysis. Critical specification is vacuum produced at the sample port, not just the
rating of the vacuum system
Vacuum Gauge Single Cold Cathode/ micro Pirani gauge
Gauge placed in close proximity to sample
port
For proper monitoring, gauge must be placed close to sample port. Measuring vacuum at pump is not indicative of pressure at sample. The 3Flex design permits automatic zeroing, ensuring
greater accuracy and repeatability
Minimum Measurable
Surface Area 0.01m2/g 0.0005m2/g (Krypton)
Standard krypton capability permits very low surface area material to be accurately analyzed
Manifold Outgas Rate
<0.1µm Hg/min <0.03 µm Hg/min Essential to limit outgas rate for accurate adsorption
measurements at critical intervals in isotherm
Low Pressure Transducers
10 mm Hg, ± 0.12% of reading
0.1mm Hg, ±0.15% of reading
10 mm Hg, ± 0.08% of reading
0.1mm Hg, ±0.08% of reading
Due to our proprietary temperature control, the actual analysis performance of the transducer has demonstrated better
accuracy than the instrument specification
Adsorptive Gas Inputs
6 Expandable to 12 Expandable versatility extends adsorbate gas range investigation
to optimize analysis
Degas 3 in situ, 6 with optional smart prep
Ambient to 450°C, programmable -
5 heating and 5 soak periods
Helium free-space can be performed after analysis to prevent helium entrapment
Dewar 3.2L capacity, >80hrs
(single tube, no isothermal jacket)
>70 Hrs.
(3 sample tubes, isothermal jackets, P0
tube, )
Redesigned and improved dewar can provide operational time greater than listed specification with unique design that permits
refilling of Dewar without interrupting analysis
Cryogen Control Isothermal jacket Permits sample to remain in the cold zone - permits refilling
Dewar without interrupting analysis. No exposed areas of sample tube above liquid cryogen level
Sample Tubes Metric, flat bottom, 9 and 12mm
Tubes are clearly marked with diameter and feature convenient
ID Spot.
• The world’s only true, 3-port, high resolution micropore instrument
• Directed method creation, including ASTM guidance, ensures maximum
user productivity and reduces new user training
• Standard features include vapor analysis and krypton capability for
low surface area measurement
• Industry leading accuracy in temperature control, A/D data
acquisition, and gas management with 12 pressure transducers
• The operational dashboard provides real-time monitoring of system
critical parameters to ensure your results and maximum instrument
uptime