Virgil C. Summer Nuclear Station Database AMR Query Page 1 of 413 Eval. Sys. Act. Sys. Component Type Comp. Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section SRP Item GALL Recom Site Match Gall Discus AC AC Pipe and Fittings PB Carbon Steel Reactor Building General Corrosion Loss of Material Inspections for Mechanical Components See Note A- AC-a See Note A- AC-b V.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation. AC AC Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components See Note A- AC-c See Note A- AC-d V.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation. AC AC Pipe and Fittings PB Carbon Steel Treated Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion Loss of Material Chemistry Program See Note A- AC-e See Note A- AC-f V.C.1-a, V.C.1.2 T.2-03, T.2-05 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation. AC AC Valves (Body Only) PB Carbon Steel Reactor Building General Corrosion Loss of Material Inspections for Mechanical Components See Note A- AC-a See Note A- AC-b V.C.1-a, V.C.1.1 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation. AC AC Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components See Note A- AC-c See Note A- AC-d V.C.1-a, V.C.1.1 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the

Upload: others

Post on 05-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 1 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

AC AC Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AC-a See Note A-AC-b

V.C.1-a, V.C.1.2

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AC AC Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AC-c See Note A-AC-d

V.C.1-a, V.C.1.2

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AC AC Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-AC-e See Note A-AC-f

V.C.1-a, V.C.1.2

T.2-03, T.2-05

Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

AC AC Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AC-a See Note A-AC-b

V.C.1-a, V.C.1.1

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AC AC Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AC-c See Note A-AC-d

V.C.1-a, V.C.1.1

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the

Page 2: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 2 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes of the credited activity in effectively managing aging during the period of extended operation.

AC AC Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-AC-e See Note A-AC-f

V.C.1-a, V.C.1.1

T.2-03, T.2-05

Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAA-1A/B, -2A/B-AH) - RBCUs

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-a, See Note A-AH-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Air Handling Units (XAA-1A/B, -2A/B-AH) - RBCUs

PB Carbon Steel Ventilation Boric Acid Corrosion (Aggressive Chemical Attack); Galvanic Corrosion, General Corrosion

Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-AH-f, See Note A-AH-g

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, MIC and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAH-12A/B-AH) - Control Room

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. For the aging effect, carbon steel and galvanized steel have similarities. The material, environment, aging

Page 3: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 3 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Air Handling Units (XAH-12A/B-AH) - Control Room

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-AH-f, See Note A-AH-g

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general, MIC and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAH-13A/B-AH) - Relay Room

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. For the aging effect, carbon steel and galvanized steel have similarities. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Air Handling Units (XAH-13A/B-AH) - Relay Room

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation

See Note A-AH-f, See Note A-AH-g

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general, MIC and pitting corrosion

Page 4: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 4 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Systems Inspections

are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAH-24A/B-AH) - Battery Room/Charging Room

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. For the aging effect, carbon steel and galvanized steel have similarities. The material, environment, aging effect requiring management and the credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Air Handling Units (XAH-24A/B-AH) - Battery Room/Charging Room

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-AH-f, See Note A-AH-g

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general, MIC and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Plenums (FH Building and CR Emergency Filter Plenums)

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. For the aging effect, carbon steel and galvanized steel have

Page 5: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 5 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

similarities. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Air Plenums (FH Building and CR Emergency Filter Plenums)

PB Carbon Steel Ventilation General Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-AH-f, See Note A-AH-g

VII.F1.1-a, VII.F1.1.1

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, MIC and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Headers

PB Copper Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-AH-m, See Note A-AH-n

VII.C1.1-a, VII.C1.1.1

T.3-17, T.3-29

No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. VCSNS determined that loss of material due to biofouling is not an aging effect requiring management for this component/component type. Also, loss of material will be managed by the Service Water System Reliability and In-Service Testing Program, where GALL references "Open Cycle Cooling Water System" and "Selective Leaching of Materials." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

Page 6: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 6 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Headers

PB Copper Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-c

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Tubes

PB, HT Copper Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-AH-m, See Note A-AH-n

VII.C1.1-a, VII.C1.1.1

T.3-17, T.3-29

No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. VCSNS determined that loss of material will be managed by the Service Water System Reliability and In-Service Testing Program, where the GALL references "Open Cycle Cooling Water System" and "Selective Leaching of Materials." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Tubesheets

PB Galvanized Steel

Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-a, See Note A-AH-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in

Page 7: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 7 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

meeting the intent of the pertinent GALL program.

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Tubesheets

PB Galvanized Steel

Ventilation Boric Acid Corrosion (Aggressive Chemical Attack); Galvanic Corrosion

Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-AH-f, See Note A-AH-g

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general, MIC and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAH-12A/B, -13A/B, -24A/B-AH) - Fins

HT Copper Ventilation Galvanic Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Preventive Maintenance Activities - Ventilation Systems Inspections

See Notes A-AH-h, A-AH-ii

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAH-12A/B, -13A/B, -24A/B-AH) - Tubes

PB, HT Copper Ventilation Galvanic Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Preventive Maintenance Activities - Ventilation Systems Inspections

See Notes A-AH-h, A-AH-ii

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to

Page 8: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 8 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAH-12A/B, -13A/B, -24A/B-AH) - Headers

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Cooling Coils (XAH-12A/B, -13A/B, -24A/B-AH) - Headers

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-AH-o, See Note A-AH-p

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will manage loss of material and cracking for this component/component type, where the GALL item references "Closed Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAH-12A/B, -13A/B, -24A/B-AH) - Tubes

PB, HT Copper Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-AH-o, See Note A-AH-p

N/A N.3-28 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

AH AH Ductwork PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical

Loss of Material Boric Acid Corrosion

See Note A-AH-k, See

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. For the aging

Page 9: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 9 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Attack) Surveillances Note A-AH-l effect, carbon steel and galvanized steel have similarities. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Ductwork PB Galvanized Steel

Ventilation None Identified None Identified None Required See Note A-AH-f, See Note A-AH-g

VII.F1.1-a N.3-03 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Ductwork PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-02 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Ductwork PB Stainless Steel Ventilation None Identified None Identified None Required See Note A-AH-j

VII.F1.4-a N.3-02 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Ductwork (fan housings and plenum housings)

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a

Page 10: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 10 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Ductwork (fan housings and plenum housings)

PB Carbon Steel Ventilation General Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-AH-f, See Note A-AH-g

VII.F1.1-a, VII.F1.1.1

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, MIC and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Ductwork (Flexible Connections)

PB Hypalon Reactor Building

Radiation Embrittlement, Thermal Embrittlement

Cracking Inspections for Mechanical Components

See Note A-AH-d

VII.F1.1-b, VII.F1.1.3

T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

AH AH Ductwork (Flexible Connections)

PB Hypalon Ventilation None Identified None Identified None Required See Note A-AH-d See Note A-AH-r

VII.F1.1-b T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Ductwork (Flexible Connections)

PB Neoprene Sheltered Radiation Embrittlement, Thermal Embrittlement

Cracking Inspections for Mechanical Components

See Note A-AH-e

VII.F1.1-b, VII.F1.1.3

T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

AH AH Ductwork (Flexible PB Neoprene Ventilation None Identified None Identified None Required See Note A- VII.F1.1-b T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area

Page 11: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 11 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Connections) AH-e See Note A-AH-r

Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Ductwork (XHD- Exhaust Air Relief Heads)

PB Galvanized Steel

Ventilation None Identified None Identified None Required See Note A-AH-f, See Note A-AH-g

VII.F1.1-a N.3-03 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Ductwork (XHD- Exhaust Air Relief Heads)

PB Galvanized Steel

Yard None Identified None Identified None Required See Note A-AH-q

VII.F1.1-a N.3-03 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Expansion Joints, Mechanical (expansion boot)

PB Rubber Reactor Building

Radiation Embrittlement, Thermal Embrittlement

Cracking Inspections for Mechanical Components

See Note A-AH-d

VII.F1.1-b, VII.F1.1.3

T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

AH AH Expansion Joints, Mechanical (expansion boot)

PB Rubber Ventilation None Identified None Identified None Required See Note A-AH-d See Note A-AH-r

VII.F1.1-b T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Expansion Joints, Mechanical (retaining rings)

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-a, See Note A-AH-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the

Page 12: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 12 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Expansion Joints, Mechanical (XEJ5001-5005-AH)

PB Hypalon Reactor Building

Radiation Embrittlement, Thermal Embrittlement

Cracking Inspections for Mechanical Components

See Note A-AH-d

VII.F1.1-b, VII.F1.1.3

T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Expansion Joints, Mechanical (XEJ5001-5005-AH)

PB Hypalon Ventilation None Identified None Identified None Required See Note A-AH-d See Note A-AH-r

VII.F1.1-b T.3-02 Yes, plant specific No VII.F1.1-b addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Heating Coils (XHC-2A/B, -3A/B, -14A/B-AH)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. For the aging effect, carbon steel and galvanized steel have similarities. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Heating Coils (XHC-2A/B, -3A/B, -14A/B-AH)

PB Galvanized Steel

Ventilation None Identified None Identified None Required See Note A-AH-f, See Note A-AH-g

VII.F1.1-a N.3-03 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for

Page 13: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 13 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Pipe and Fittings (Nuclear Sampling)

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-02 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Pipe and Fittings - RBCU Cooling Coil Manifold

PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-AH-m, See Note A-AH-n

VII.C1.1-a, VII.C1.1.1

T.3-17 No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. VCSNS determined that loss of material due to biofouling is not an aging effect requiring management for this component/component type. Also, loss of material will be managed by the Service Water System Reliability and In-Service Testing Program where the GALL references "Open Cycle Cooling Water System" and "Selective Leaching of Materials." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

AH AH Pipe and Fittings - RBCU Cooling Coil Manifold

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-a, See Note A-AH-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 14: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 14 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

AH AH Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-02 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Tube & Tube Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-AH-k, See Note A-AH-l

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Tube & Tube Fittings PB Stainless Steel Ventilation None Identified None Identified None Required See Note A-AH-j

VII.F1.4-a N.3-02 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Valves (Body Only) - XPR- duct pressure relief valves

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-02 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Valves (Body Only) - XPR- duct pressure relief valves

PB Stainless Steel Ventilation None Identified None Identified None Required See Note A-AH-j

VII.F1.4-a N.3-02 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Valves (Body Only) (XVB-1A, -2A, -3A/B, -4A/B-AH)

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-k, See Note A-AH-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this

Page 15: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 15 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AH AH Valves (Body Only) (XVB-1A/B, -2A/B, -3A/B, -4A/B-AH)

PB Carbon Steel Ventilation None Identified None Identified None Required See Note A-AH-f, See Note A-AH-g

VII.F1.1-a N.3-03 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

AH AH Valves (Body Only) (XVB-1B, -2B-AH)

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AH-a, See Note A-AH-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AS AS Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-AS-a See Note A-AS-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for these items. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AS AS Pipe and Fittings PB Carbon Steel Treated Crevice Corrosion, Loss of Material Chemistry See Note A- VIII.B1.1-a T.4-07 No Yes GALL Item No. VIII.B1.1-a addresses piping

Page 16: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 16 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Water Galvanic Corrosion, General Corrosion, Pitting Corrosion

Program AS-c See Note A-AS-d

and fittings. The material, environment, aging effect/mechanisms requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect/mechanisms and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AS AS Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AS-a See Note A-AS-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AS AS Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-AS-c See Note A-AS-d

VIII.B1.2-a, VIII.B1.2.1

T.4-07 No Yes GALL Item Nos. VIII.B1.2-a and VIII.B1.2.1 address valves, and body and bonnet, respectively. The material, environment, aging effect/mechanisms requiring management, and the credited program for this component/component type are consistent with the identified GALL items which have the same material, environment, aging effect/mechanisms and credited program. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AS AS Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X

V.C.1-b, V.C.1.1

N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the

Page 17: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 17 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in TR00160-010, Attachment X.

AS AS Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-AS-e See Note A-AS-f

V.A.4-a, V.A.4.1

N.4-05 No Partial GALL Item Nos. V.A.4-a and V.A.4.1 address valves, and body and bonnet, respectively. Except as noted, the AMR results for this component/component type are consistent with the identified GALL items in material, aging effect/mechanism and credited program. Relative to the environment, the identified GALL items reference chemically treated borated water, while the component/component type AMR results consider treated water. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL progam.

BD BD Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BD-a, See Note A-BD-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BD BD Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BD-c, See Note A-BD-d

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the

Page 18: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 18 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

same material, environment, aging effect, and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BD BD Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-BD-e, See Note A-BD-f

VIII.F.1-b, VIII.F.1.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.F.1-b addresses Steam Generator Blowdown System piping and fittings. VCSNS determined that the Chemistry Program will manage loss of material for this component/component type where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BD BD Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BD-a, See Note A-BD-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BD BD Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BD-c, See Note A-BD-d

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring

Page 19: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 19 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BD BD Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-BD-e, See Note A-BD-f

VIII.F.2-b, VIII.F.2-1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.F.2-b addresses Steam Generator Blowdown System valve bodies. VCSNS determined that the Chemistry Program will manage loss of material and cracking for this component/component type where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Condensers (XEV0008-CN1, XEV0008-CN2), Recycle Evaporator - Channel Head

PB Carbon Steel/Stainless Steel Combination

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BR-a, See Note A-BR-b

VII.A3.4-b, VII.A3.4.2

T.3-14 No Yes VII.A3.4-b addresses Spent Fuel Pool Cooling and Cleanup heat exchangers. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 20: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 20 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

BR BR Condensers (XEV0008-CN1, XEV0008-CN2), Recycle Evaporator - Channel Head (nozzles)

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.A3.4-a, VII.A3.4.2

T.3-15 No Partial VII.A3.4-a addresses Spent Fuel Pool Cooling and Cleanup heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for carbon steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System". The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. Certain aging effects not addressed by this GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Condensers (XEV0008-CN1, XEV0008-CN2), Recycle Evaporator - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Condensers (XEV0008-CN1, XEV0008-CN2), Recycle Evaporator - Tubesheet

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the

Page 21: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 21 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Heat Exchanger (XEV0008-HE2), Recycle Evaporator - Shell

PB Carbon Steel/Stainless Steel Combination

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BR-a, See Note A-BR-b

VII.A3.4-b, VII.A3.4.1

T.3-14 No Yes VII.A3.4-b addresses Spent Fuel Pool Cooling and Cleanup heat exchangers. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BR BR Heat Exchanger (XEV0008-HE2), Recycle Evaporator - Shell (nozzles)

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.A3.4-a, VII.A3.4.1

T.3-15 No Partial VII.A3.4-a addresses Spent Fuel Pool Cooling and Cleanup heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for carbon steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System". The material, environment, and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Heat Exchanger (XEV0008-HE2), Recycle Evaporator - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the

Page 22: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 22 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Heat Exchanger (XEV0008-HE2), Recycle Evaporator - Tubesheet

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Heat Exchanger (XHE0021), Recycle Evap. Concentrates Sample - Manifolds

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-e, See Note A-BR-f

V.A.4-a, V.A.4.1

N.3-06 No Yes V.A.4-a addresses Containment Spray System components. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effects and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BR BR Heat Exchanger (XHE0021), Recycle Evap. Concentrates

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are

Page 23: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 23 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Sample - Manifolds Cracking (SCC) consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Heat Exchanger (XHE0021), Recycle Evap. Concentrates Sample - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BR-a, See Note A-BR-b

VII.A3.4-b, VII.A3.4.1

T.3-14 No Yes VII.A3.4-b addresses Spent Fuel Pool Cooling and Cleanup heat exchangers. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BR BR Heat Exchanger (XHE0021), Recycle Evap. Concentrates Sample - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.A3.4-a, VII.A3.4.1

T.3-15 No Partial VII.A3.4-a addresses Spent Fuel Pool Cooling and Cleanup heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for carbon steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System". The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of

Page 24: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 24 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation. BR BR Heat Exchanger

(XHE0021), Recycle Evap. Concentrates Sample - Tubes

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-e, See Note A-BR-f

V.A.4-a, V.A.4.1

N.3-06 No Yes V.A.4-a addresses Containment Spray System components. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effects and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BR BR Heat Exchanger (XHE0021), Recycle Evap. Concentrates Sample - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

BR BR Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-e, See Note A-BR-f

V.A.4-a, V.A.4.1

N.3-06 No Yes V.A.4-a addresses Containment Spray System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the

Page 25: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 25 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BR BR Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-BR-b

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Pipe and Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-BS-a

V.C.1-b N.3-11 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010 Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-BS-b

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Pipe and Fittings PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-BS-c

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Tube & Tube Fittings PB Carbon Steel Air-Gas Galvanic Corrosion, General Corrosion

Loss of Material Service Air System Inspection

See Note A-BS-d See Note A-BS-f

VII.H2.3-a, VII.H2.3.1

N.3-14 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, except that VCSNS determined that loss of material due to galvanic corrosion is an additional applicable aging effect and loss of

Page 26: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 26 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material due to crevice and pitting corrosion are not applicable aging effects. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

BS BS Tube & Tube Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-BS-e See Note A-BS-g

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BS BS Tube & Tube Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-BS-a

V.C.1-b N.3-11 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010 Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-BS-b

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Valves (Body Only) PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-BS-a

V.C.1-b N.3-11 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and

Page 27: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 27 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010 Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-BS-b

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BS BS Valves (Body Only) PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-BS-c

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Flex Hose PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Flex Hose PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CC-c See Note A-CC-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a

Page 28: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 28 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC RC Heat Exchangers (MPP0043A/B/C-HE2), Low. Bearing Oil Cooler - Tubes

PB Copper-Nickel Oil None Identified None Identified None Required See Note A-CC-v

N/A N.2-04 N/A N/A The material/environment combination for thiscomponent/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC RC Heat Exchangers (MPP0043A/B/C-HE2), Low. Bearing Oil Cooler - Tubes

PB Copper-Nickel Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-CC-q See Note A-CC-r

VII.C1.3-a, VII.C1.3.1

N.3-28 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components, with microbiologically induced corrosion and biofouling assumed to be a concern only in the raw water environment. Loss of material due to selective leaching was determined not to be an aging effect for this component material-environment combination at VCSNS. Additional aging effects requiring evaluation for VCSNS includes heat exchanger fouling due to particulates and loss of material due to erosion-corrosion. Also, rather than the Open-Cycle Cooling Water System AMP and the Selective Leaching of Materials AMP, all of the applicable aging effects, are managed by the Chemistry Program (which is consistent with GALL XI.M2 but not listed for this GALLitem) and the Heat Exchanger Inspections. The component/component type aging is managed by a program/activity that is not evaluated in GALL Chapter XI, and is therfore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CC RC Heat Exchangers (MPP0043A/B/C-HE1), Upp. RCP Mot. Oil Cooler - Tubes

PB Copper-Nickel Oil None Identified None Identified None Required See Note A-CC-v

N/A N.2-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC RC Heat Exchangers (MPP0043A/B/C-HE1), Upp. RCP Mot. Oil Cooler - Tubes

PB Copper-Nickel Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-CC-q See Note A-CC-r

VII.C1.3-a, VII.C1.3.1

N.3-28 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components, with microbiologically induced corrosion and biofouling assumed to be a concern only in the raw water environment. Loss of material due to selective leaching was determined not to be an aging effect for this component material-environment combination at VCSNS. Additional aging effects requiring evaluation

Page 29: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 29 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

for VCSNS includes heat exchanger fouling due to particulates and loss of material due to erosion-corrosion. Also, rather than the Open-Cycle Cooling Water System AMP and the Selective Leaching of Materials AMP, all of the applicable aging effects, are managed by the Chemistry Program (which is consistent with GALL XI.M2 but not listed for this GALLitem) and the Heat Exchanger Inspections. The component/component type aging is managed by a program/activity that is not evaluated in GALL Chapter XI, and is therfore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CC RC Heat Exchangers (MPP0043A/B/C-HE1), Upp. RCP Mot. Oil Cooler - Tubesheets

PB Copper-Nickel Oil None Identified None Identified None Required See Note A-CC-v

N/A N.2-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC RC Heat Exchangers (MPP0043A/B/C-HE1), Upp. RCP Mot. Oil Cooler - Tubesheets

PB Copper-Nickel Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion

Loss of Material Chemistry Program, Heat Exchanger Inspections

See Note A-CC-q See Note A-CC-r

VII.C1.3-a, VII.C1.3.1

N.3-28 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components, with microbiologically induced corrosion and biofouling assumed to be a concern only in the raw water environment. Loss of material due to selective leaching was determined not to be an aging effect for this component material-environment combination at VCSNS. Additional aging effects requiring evaluation for VCSNS includes heat exchanger fouling due to particulates and loss of material due to erosion-corrosion. Also, rather than the Open-Cycle Cooling Water System AMP and the Selective Leaching of Materials AMP, all of the applicable aging effects, are managed by the Chemistry Program (which is consistent with GALL XI.M2 but not listed for this GALLitem) and the Heat Exchanger Inspections. The component/component type aging is managed by a program/activity that is not evaluated in GALL Chapter XI, and is therfore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B),

PB Carbon Steel Raw Water Erosion, Galvanic Corrosion, General

Loss of Material; Heat Exchanger

Service Water System Reliability

See Note A-CC-e

VII.C1.3-a, VII.C1.3.3

T.3-17 No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. Except as noted,

Page 30: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 30 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Component Cooling - Channel Head

Corrosion, Crevice Corrosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

Fouling and In-Service Testing Program

See Note A-CC-f

the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Channel Head

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-a See Note A-CC-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-a See Note A-CC-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this

Page 31: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 31 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Tubes

PB, HT Stainless Steel Raw Water Crevice Corrosion, Erosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-CC-j See Note A-CC-k

VII.C1.1-a, VII.C1.1.1

T.3-17 No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Tubes

PB, HT Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CC-c See Note A-CC-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Tubesheets

PB Carbon Steel Raw Water Erosion, Galvanic Corrosion, General Corrosion, Crevice Corrosion, Pitting

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-CC-e See Note A-CC-f

VII.C1.3-a, VII.C1.3.3

T.3-17 No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent

Page 32: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 32 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Tubesheets

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of this credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CC CC Motors (MPP0001A/B/C), CC Pump Casing/Int. Bearing Cooler only - Fins

HT Aluminum Ventilation * Particulates Heat Exchanger Fouling

Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-CC-s See Note A-CC-w

N/A N.3-24 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Motors (MPP0001A/B/C), CC Pump Casing/Int. Bearing Cooler only - Tubes

PB, HT Copper-Nickel Treated Water

Crevice Corrosion, Galvanic Corrosion, Pitting Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-CC-q See Note A-CC-r

VII.C1.3-a, VII.C1.3.1

N.3-28 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components, with microbiologically induced corrosion and biofouling assumed to be a concern only in the raw water environment. Loss of material due to selective leaching was determined not to be an aging effect for this component material-environment combination at VCSNS. Additional aging effects requiring evaluation for VCSNS includes heat exchanger fouling due to particulates and loss of material due to erosion-corrosion. Also, rather than the

Page 33: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 33 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Open-Cycle Cooling Water System AMP and the Selective Leaching of Materials AMP, all of the applicable aging effects, are managed by the Chemistry Program (which is consistent with GALL XI.M2 but not listed for this GALLitem) and the Heat Exchanger Inspections. The component/component type aging is managed by a program/activity that is not evaluated in GALL Chapter XI, and is therfore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CC CC Motors (MPP0001A/B/C), CC Pump Casing/Int. Bearing Cooler only - Tubes

PB, HT Copper-Nickel Ventilation * Particulates Heat Exchanger Fouling

Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-CC-t See Note A-CC-u

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. The Preventive Maintenance Activities - Ventilation Systems Inspections will adequately manage this aging effect. VCSNS did not find the aging effects of loss of material due to pitting and crevice corrosion as stated in this GALL item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of these activities in effectively managing aging during the period of extended operation.

CC CC Motors (MPP0001A/B/C), CC Pump Casing/Int. Bearing Cooler only - Tubesheets

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CC CC Motors (MPP0001A/B/C), CC

PB Carbon Steel Ventilation * Galvanic Corrosion, General Corrosion

Loss of Material Preventive Maintenance

See Note A-CC-o

VII.F1.4-a, VII.F1.4.1

T.3-05 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The

Page 34: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 34 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Pump Casing/Int. Bearing Cooler only - Tubesheets

Activities - Ventilation Systems Inspections

See Note A-CC-p

component/component type AMR results are consistent with the identified GALL item in material and environment. The Preventive Maintenance Activities - Ventilation Systems Inspections will adequately manage these aging effects. The referenced GALL item's aging effects of loss of material due to pitting and crevice corrosion were found not applicable at VCSNS, but the possibility of loss of material due to galvanic corrosion exists. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Motors (MPP0001A/B/C), CC Pump Casing/Int. Bearing Cooler only - Water Boxes

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-a See Note A-CC-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Motors (MPP0001A/B/C), CC Pump Casing/Int. Bearing Cooler only - Water Boxes

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water system components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

Page 35: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 35 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

CC CC Orifices PB, TH Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-CC-l

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Orifices PB, TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CC-c See Note A-CC-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-m See Note A-CC-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion Loss of Material Boric Acid See Note A- VII.I.1-a, T.3-14 No Yes VII.I.1-a addresses external surfaces of

Page 36: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 36 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(Aggressive Chemical Attack)

Corrosion Surveillances

CC-a See Note A-CC-b

VII.I.1.1 carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Pipe and Fittings (Thermowells)

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Pipe and Fittings (Thermowells)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CC-l

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Pipe and Fittings (Thermowells)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion;

Loss of Material; Cracking

Chemistry Program

See Note A-CC-c

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS

Page 37: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 37 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Stress Corrosion Cracking (SCC)

See Note A-CC-d

determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Pumps (Casing Only) (XPP0058A/B/C), CC Booster Pumps

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CC-c See Note A-CC-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Pumps (Casing Only) (XPP0001A/B/C), CC Pumps

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-a See Note A-CC-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 38: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 38 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

CC CC Pumps (Casing Only) (XPP0001A/B/C), CC Pumps

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Pumps (Casing Only) (XPP0058A/B/C), CC Booster Pumps

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CC-l

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Tank (XTK0003), CC Surge Tank

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-a See Note A-CC-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Tank (XTK0003), CC Surge Tank

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Corrosive Impacts of Alternate Wetting and Drying

Loss of Material Chemistry Program; Above Ground Tank Inspection

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

N.3-19 No No VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program and Above Ground Tank Inspection will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent

Page 39: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 39 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

with the identified GALL item which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of the credited program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program and activity in effectively managing aging during the period of extended operation and in detecting and characterizing the affects of aging due to the corrosive impacts of alternate wetting and drying.

CC CC Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Tube & Tube Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-CC-l

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. VCSNS did not identify loss of material due to pitting and crevice corrosion for this component. The aging effect will be managed by the Inspections for Mechanical Components. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CC-c See Note A-CC-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the

Page 40: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 40 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-m See Note A-CC-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CC-a See Note A-CC-b

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CC CC Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CC-g See Note A-CC-h

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program.

Page 41: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 41 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b, V.C.1.2

N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL items in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CC-l

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CC CC Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CC-c See Note A-CC-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CO CO Tank (XTK0008), Condensate Storage

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Corrosive Impacts of Alternate Wetting and Drying

Loss of Material Chemistry Program; Above Ground Tank Inspection

See Note A-CO-a, See Note A-CO-b

VIII.E.5-a, VIII.E.5.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.E.5-a addresses the Condensate Storage Tank internal surfaces. The material, environment, aging effects requiring management and credited programs for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effects and credited programs. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as

Page 42: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 42 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection, which includes measures to verify the effectiveness of water chemistry control. The Above Ground Tank Inspection is a one-time inspection activity that will detect and characterize the loss of material due to corrosive impacts of alternate wetting and drying at the air-water interface inside the tank and does not serve to verify the effectiveness of chemistry control. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation, and of the activity in detecing and characterizing the affects of aging , if any.

CO CO Tank (XTK0008), Condensate Storage

PB Carbon Steel Yard General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CO-c, See Note A-CO-d

VIII.E.5-c, VIII.E.5.1

T.4-11 No No VIII.E.5-c addresses the Condensate Storage Tank external surfaces. Aging effects for this component/component type are managed by an activity that is not evaluated in GALL Chapter XI and is therefore specific to VCSNS. Inspections for Mechanical Components manages loss of material for carbon steel components exposed to ambient conditions by performing visual inspections. The Aboveground Carbon Steel Tanks Program includes preventive measures to mitigate corrosion by protecting the external surface of carbon steel tanks with paint or coatings, and relies on periodic system walkdowns to monitor degradation. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

DG DG Expansion Joints (XEG0001A/B-EJ1, EJ2), Diesel Engine Exhaust

PB Carbon Steel Air-Gas General Corrosion Loss of Material Diesel Generator Systems Inspection

See Note A-DG-a See Note A-DG-n

VII.H2.4-a, VII.H2.4.1

T.3-05 Yes, plant specific No VII.H2.4-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. VCSNS determined that crevice and pitting corrosion were not applicable aging effects. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Expansion Joints (XEG0001A/B-EJ1, EJ2),

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical

See Note A-DG-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The

Page 43: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 43 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Diesel Engine Exhaust Components See Note A-DG-c

component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Expansion Joints (XEG0001A/B-EJ1, EJ2), Diesel Engine Exhaust

PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-DG-d

VII.F2.4-a, VII.F2.4.1

N.3-10 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Expansion Joints (XEG0001A/B-EJ1, EJ2), Diesel Engine Exhaust

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-DG-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Filters (XEG0001A/B-FL1, FL2)

PB, FI Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.1

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Filters (XEG0001A/B-FL1, FL2, FL5)

PB, FI Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Filters (XEG0001A/B-FL3, FL4)

PB, FI Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.2-a T.3-05 Yes, plant specific No VII.H2.2-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to

Page 44: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 44 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

require management during the period of extended operation as detailed in the applicable note.

DG DG Filters (XEG0001A/B-FL3, FL4)

PB, FI Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Flexible Coupling PB Neoprene Air-Gas None Identified None Identified None Required See Note A-DG-zn

VII.F2.4-b, VII.F2.4.2

T.3-02 Yes, plant specific No VII.F2.4-b addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Flexible Coupling PB Neoprene Sheltered Radiation Embrittlement, Thermal Embrittlement

Cracking Inspections for Mechanical Components

See Note A-DG-zm

VII.F2.4-b, VII.F2.4.2

T.3-02 Yes, plant specific No VII.F2.4-b addresses Auxiliary and Radwaste Area Ventilation System components. The component AMR results are consistent with the identified GALL item in material and environment. The Inspections for Mechanical Components will manage the aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

DG DG Flexible Coupling PB Rubber Oil/Fuel Oil None Identified None Identified None Required See Note A-DG-zo

N/A N.3-26 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Flexible Coupling PB Rubber Sheltered Radiation Embrittlement, Thermal Embrittlement

Cracking Inspections for Mechanical Components

See Note A-DG-zm

VII.F2.4-b, VII.F2.4.2

T.3-02 Yes, plant specific No VII.F2.4-b addresses Auxiliary and Radwaste Area Ventilation System components. The component AMR results are consistent with the identified GALL item in material and environment. The Inspections for Mechanical Components will manage the aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for

Page 45: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 45 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

DG DG Flexible Hose PB Rubber Oil/Fuel Oil None Identified None Identified None Required See Note A-DG-zo

N/A N.3-26 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Flexible Hose PB Rubber Sheltered Radiation Embrittlement, Thermal Embrittlement

Cracking Inspections for Mechanical Components

See Note A-DG-zm

VII.F2.4-b, VII.F2.4.2

T.3-02 Yes, plant specific No VII.F2.4-b addresses Auxiliary and Radwaste Area Ventilation System components. The component AMR results are consistent with the identified GALL item in material and environment. The Inspections for Mechanical Components will manage the aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

DG DG Flexible Hose PB Rubber Treated Water

None Identified None Identified None Required See Note A-DG-zp

N/A N.3-26 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Channel Head

PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-DG-zd See Note A-DG-ze

VII.C1.1-a, VII.C1.1.1

T.3-17 No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Selective leaching is not an applicable aging effect for this component and so the GALL-referenced Selective Leaching AMP is not applicable. VCSNS determined that galvanic corrosion is not an applicable aging effect. However, the attributes of this activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

Page 46: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 46 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Channel Head

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-DG-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Channel Head

PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-DG-zd See Note A-DG-ze

VII.C1.1-a, VII.C1.1.1

T.3-17 No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Selective leaching is not an applicable aging effect for this component and so the GALL-referenced Selective Leaching AMP is not applicable. VCSNS determined that galvanic corrosion is not an applicable aging effect. However, the attributes of this activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Channel Head

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-DG-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B), DG Turbo Cooler (Intercooler) - Head

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B),

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion,

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS

Page 47: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 47 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG Turbo Cooler (Intercooler) - Head

General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

See Note A-DG-zg

determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B), DG Turbo Cooler (Intercooler) - Shell

PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.3-a T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B), DG Turbo Cooler (Intercooler) - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B), DG Turbo Cooler (Intercooler) - Tubes

PB, HT Brass Air-Gas None Identified None Identified None Required See Note A-DG-e

N/A N.3-12 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B), DG Turbo Cooler (Intercooler) - Tubes

PB, HT Brass Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Particulates

Loss of Material; Cracking; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-DG-zj See Note A-DG-zk

VII.C1.3-a, VII.C1.3.5

N.3-28 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material (copper alloy), environment and aging effects (microbiologically induced corrosion and biofouling are assumed to be a

Page 48: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 48 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

concern only in the raw water environment). However, additional aging effects requiring evaluation for VCSNS include cracking due to stress corrosion cracking, loss of material due to erosion-corrosion and heat exchanger fouling due to particulates. GALL aging effects for this item are managed by the Open-Cycle Cooling Water System Program. Selective leaching is determined not to applicable for this component. All of the applicable aging effects are managed by the Chemistry Program and Heat Exchanger Inspections. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B), DG Turbo Cooler (Intercooler) - Tubesheet

PB Brass Air-Gas None Identified None Identified None Required See Note A-DG-e

N/A N.3-12 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XEG0001A/B-HE2A/B), DG Turbo Cooler (Intercooler) - Tubesheet

PB Brass Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion, Selective Leaching; Stress Corrosion Cracking (SCC); Particulates

Loss of Material; Cracking; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-DG-zj See Note A-DG-zk

VII.C1.3-a, VII.C1.3.4

N.3-28 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material (copper alloy), environment and aging effects (microbiologically induced corrosion and biofouling are assumed to be a concern only in the raw water environment). However, additional aging effects requiring evaluation for VCSNS include cracking due to stress corrosion cracking, loss of material due to erosion-corrosion and heat exchanger fouling due to particulates. GALL aging effects for this item are managed by the Open-Cycle Cooling Water System Program and Selective Leaching AMP. All of the applicable aging effects are managed by the Chemistry Program and the Heat Exchanger Inspections. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

Page 49: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 49 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG DG Heat Exchangers (XEG0001A/B-HE1), DG Governor Lube Oil Cooler - Shell

PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XEG0001A/B-HE1), DG Governor Lube Oil Cooler - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XEG0001A/B-HE1), DG Governor Lube Oil Cooler - Tubes

PB, HT Brass Oil None Identified None Identified None Required See Note A-DG-v

VII.G.7-b, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XEG0001A/B-HE1), DG Governor Lube Oil Cooler - Tubes

PB, HT Brass Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Particulates

Loss of Material; Cracking; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-DG-zj See Note A-DG-zk

VII.C1.3-a, VII.C1.3.5

N.3-28 No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material (copper alloy), environment and aging effects (microbiologically induced corrosion and biofouling are assumed to be a concern only in the raw water environment). However, additional aging effects requiring evaluation for VCSNS include cracking due to stress corrosion cracking, loss of material due to erosion-corrosion and heat exchanger fouling due to particulates. GALL aging effects for this item are managed by the Open-Cycle Cooling Water System Program. Selective leaching is determined not to be applicable for this component. All of the applicable aging effects are managed by the Chemistry Program and Heat Exchanger Inspections. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to

Page 50: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 50 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Shell

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf See Note A-DG-zg

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Shell

PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item

Page 51: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 51 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Tubes

PB, HT Brass Oil None Identified None Identified None Required See Note A-DG-v

VII.G.7-b, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Tubes

PB, HT Brass Raw Water Crevice Corrosion, Erosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-DG-zb See Note A-DG-zc

VII.C1.3-a, VII.C1.3.5

T.3-17, T.3-29

No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material (copper alloy), environment and aging effects. GALL aging effects are managed by the Open-Cycle Cooling Water System Program and Selective Leaching of Materials AMP. Selective leaching and galvanic corrosion are not applicable aging effects for this component and so the GALL-referenced Selective Leaching AMP is not applicable. Certain aging effects not addressed by the GALL item are also managed by the credited program. VCSNS determined that galvanic corrosion was not an applicable aging effect. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Tubes

PB, HT Brass Raw Water Crevice Corrosion, Erosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-DG-zb See Note A-DG-zc

VII.C1.3-a, VII.C1.3.5

T.3-17, T.3-29

No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item, which has a similar material (copper alloy), environment and aging effects. GALL aging effects are managed by the Open-Cycle Cooling Water System Program and Selective Leaching of Materials AMP. Selective leaching and galvanic corrosion are not applicable aging effects for this component and so the GALL-referenced Selective Leaching AMP is not applicable. Certain aging effects not addressed by the

Page 52: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 52 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL item are also managed by the credited program. VCSNS determined that galvanic corrosion is not an applicable aging effect. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Tubes

PB, HT Brass Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Particulates

Loss of Material; Cracking; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-DG-zj See Note A-DG-zk

VII.C1.3-a, VII.C1.3.5

N.3-28 No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material (copper alloy), environment and aging effects (microbiologically induced corrosion and biofouling are assumed to be a concern only in the raw water environment). However, additional aging effects requiring evaluation for VCSNS include cracking due to stress corrosion cracking, loss of material due to erosion-corrosion and heat exchanger fouling due to particulates. GALL aging effects for this item are managed by the Open-Cycle Cooling Water System Program. All of the applicable aging effects are managed by the Chemistry Program and Heat Exchanger Inspections. Selective leaching is determined not to be applicable for this component. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Tubesheet(s)

PB Stainless Steel Oil None Identified None Identified None Required See Note A-DG-s

VIII.G.5-d, VIII.G.5.3

N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. At VCSNS, the lube oil environment is not contaminated with water, and so the GALL aging effects are not applicable. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heat Exchangers (XHE0017A/B-HE1), DG Lube Oil Cooler - Tubesheet(s)

PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Pitting Corrosion, Microbiologically

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-DG-zd See Note A-DG-ze

VII.C1.1-a, VII.C1.1.1

T.3-17 No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent

Page 53: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 53 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Induced Corrosion (MIC); Biological Materials, Particulates

with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Selective leaching is not an applicable aging effect for this component and so the GALL-referenced Selective Leaching AMP is not applicable. VCSNS determined that galvanic corrosion is not an applicable aging effect. However, the attributes of this activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Tubesheet(s)

PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-DG-zd See Note A-DG-ze

VII.C1.1-a, VII.C1.1.1

T.3-17 No Partial VII.C1.1-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Selective leaching is not an applicable aging effect for this component and so the GALL-referenced Selective Leaching AMP is not applicable. VCSNS determined that galvanic corrosion is not an applicable aging effect. However, the attributes of this activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Heat Exchangers (XHE0017A/B-HE2, HE3), Jacket Water; Intercooler&Injector Clg Wtr - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zh See Note A-DG-zi

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program.

Page 54: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 54 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Heaters (Body Only) (XEG0001A/B-HC1), Lube Oil

PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Heaters (Body Only) (XEG0001A/B-HC2), Jacket Water

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf See Note A-DG-zg

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Heaters (Body Only) (XEG0001A/B-HC1, -HC2), Lube Oil & Jacket Water

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Mufflers (XNA0007A/B), DG Exhaust

PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.4-a, VII.H2.4.2

N.3-10 Yes, plant specific No VII.H2.4-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the

Page 55: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 55 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

applicable note. DG DG Mufflers (XNA0007A/B),

DG Exhaust PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for

Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Orifices PB, TH Stainless Steel Air-Gas None Identified None Identified None Required See Note A-DG-d

VII.F2.4-a, VII.F2.4.1

T.3-05 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Orifices PB, TH Stainless Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-q See Note A-DG-r

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

No VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program). VCSNS determined that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-DG-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Orifices - PS1 thru PS9 PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A- V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation

Page 56: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 56 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG-g components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Orifices - PS1 thru PS9 PB, TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zh See Note A-DG-zi

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Pipe and Fittings PB Brass Oil None Identified None Identified None Required See Note A-DG-v

VII.G.7-b, VII.G.7.1

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Pipe and Fittings PB Brass Sheltered None Identified None Identified None Required See Note A-DG-h

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Pipe and Fittings PB Brass Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion, Selective Leaching; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program, Heat Exchanger Inspections

See Note A-DG-zj See Note A-DG-zk

VII.C1.3-a, VII.C1.3.5

N.3-28 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material (copper alloy), environment and aging effects (microbiologically induced corrosion and biofouling are assumed to be a concern only in the raw water environment). However, additional aging effects requiring evaluation for VCSNS include cracking due to

Page 57: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 57 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

stress corrosion cracking and loss of material due to erosion-corrosion. GALL aging effects for this item are managed by the Open-Cycle Cooling Water System Program and Selective Leaching AMP. All of the VCSNS aging effects are managed by the Chemistry Program and Heat Exchanger Inspections. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

DG DG Pipe and Fittings PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.4-a, VII.H2.4.1

N.3-10 Yes, plant specific No VII.H2.4-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Pipe and Fittings PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.1

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Pipe and Fittings PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. VCSNS determined that additional aging effects are loss of material due to galvanic corrosion and microbiologically induced corrosion (MIC), which will also be managed by the credited activity. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion,

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf See Note A-

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS determined that the Chemistry Program will

Page 58: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 58 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Pitting Corrosion; Stress Corrosion Cracking (SCC)

DG-zg adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Pipe and Fittings PB Carbon Steel Underground Crevice Corrosion, Pitting Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Buried Piping and Tanks Inspection

See Note A-DG-za

VII.H1.1-b, VII.H1.1.2

T.3-18 Yes, detection of aging effects and operating experience are to be further evaluated.

Partial VII.H1.1-b addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Pipe and Fittings PB Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-DG-y

VII.H1.1-a, VII.H1.1.1

T.3-05 Yes, plant specific No VII.H1.1-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Certain aging effects not addressed by this GALL item are also managed by the credited program. VCSNS determined that loss of material due to crevice and pitting corrosion are not applicable aging effects. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Pipe and Fittings PB Copper Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-t See Note A-DG-u

N/A N.3-27 N/A N/A The copper and fuel oil combination is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type, are therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing

Page 59: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 59 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

aging during the period of extended operation.

DG DG Pipe and Fittings PB Copper Sheltered None Identified None Identified None Required See Note A-DG-h

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Pumps (Casing Only) (XEG0001A/B-PP2, 3), DG Rocker Arm Lube & Prelube

PB Cast Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-k See Note A-DG-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. Cast iron has certain similarities with carbon steel. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Pumps (Casing Only) (XEG0001A/B-PP5, 6), Attached & Auxiliary Fuel Oil

PB Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Pumps (Casing Only) (XEG0001A/B-PP5, 6), Attached & Auxiliary Fuel Oil

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 60: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 60 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation.

DG DG Pumps (Casing Only) (XEG0001A/B-PP7), Jacket Water Warm-up

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf See Note A-DG-zg

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Pumps (Casing Only) (XEG0001A/B-PP7, 8, 9), Jacket Water Warm-up, Jacket Water, Intercooler Water

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Pumps (Casing Only) (XEG0001A/B-PP8), Jacket Water

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf See Note A-DG-zg

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of

Page 61: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 61 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation. DG DG Pumps (Casing Only)

(XEG0001A/B-PP9), Intercooler Water

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf See Note A-DG-zg

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Pumps (Casing Only) (XEG0001A/B-PP1, 4), DG Attached Lube Oil & Lube Oil Filter Pump

PB Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Pumps (Casing Only) (XEG0001A/B-PP1, 4), DG Attached Lube Oil & Lube Oil Filter Pump

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 62: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 62 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation.

DG DG Pumps (Casing Only) (XEG0001A/B-PP2, 3), DG Rocker Arm Lube & Prelube

PB Cast Iron Oil None Identified None Identified None Required See Note A-DG-w

N/A N.3-05 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Pumps (Casing Only) (XPP0004A/B, -141A/B), DG Fuel Oil Transfer

PB Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Pumps (Casing Only) (XPP0004A/B, -141A/B), DG Fuel Oil Transfer

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Accumulators (XEG0001A/B-OR1), DG Rocker Lube Oil Reservoir

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during

Page 63: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 63 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the period of extended operation. DG DG Accumulators

(XEG0001A/B-OR1), DG Rocker Lube Oil Reservoir

PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Reservoir - Air Start PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.3-a T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Reservoir - Air Start PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Sight Glass (Body Only) PB Glass Air-Gas None Identified None Identified None Required See Note A-DG-zl

N/A N.3-23 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Sight Glass (Body Only) PB Glass Oil/Fuel Oil None Identified None Identified None Required See Note A-DG-x

N/A N.3-23 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Sight Glass (Body Only) PB Glass Sheltered None Identified None Identified None Required See Note A-DG-j

N/A N.3-23 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 64: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 64 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG DG Silencers (XHD0013A/B/C/D)

PB, FI Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.3-a T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Silencers (XHD0013A/B/C/D)

PB, FI Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Strainers (Body Only) (XEG0001A/B-ST1, 2)

PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Strainers (Body Only) (XEG0001A/B-ST1, 2)

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Strainers (Body Only) (XEG0001A/B-ST3, 4)

PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.2-a T.3-05 Yes, plant specific No VII.H2.2-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Strainers (Body Only) (XEG0001A/B-ST3, 4)

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are

Page 65: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 65 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG-c consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Strainers (Body Only) (XST0088A/B/C/D)

PB Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Strainers (Body Only) (XST0088A/B/C/D)

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tanks (XEG0001A/B-TK1)

PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.3-a T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tanks (XEG0001A/B-TK1, 2 & 3)

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical

See Note A-DG-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The

Page 66: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 66 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Components See Note A-DG-c

component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tanks (XEG0001A/B-TK2)

PB Carbon Steel Fuel Oil Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program). Certain aging effects not addressed by the GALL item are also managed by the credited program. VCSNS determined that biofouling is not an applicable aging effect. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Tanks (XEG0001A/B-TK3)

PB Carbon Steel Fuel Oil Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program). Certain aging effects not addressed by the GALL item are also managed by the credited program. VCSNS determined that biofouling is not an applicable aging effect. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 67: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 67 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG DG Tanks (XTK0020A/B), Fuel Oil Day

PB Carbon Steel Fuel Oil Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program). Certain aging effects not addressed by the GALL item are also managed by the credited program. VCSNS determined that biofouling is not an applicable aging effect. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Tanks (XTK0020A/B), Fuel Oil Day

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tanks (XTK0053A/B), Fuel Oil Storage

PB Carbon Steel Fuel Oil Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects, and program (VCSNS Fuel Oil Chemistry included in Chemistry Program). Certain aging effects not addressed by the GALL item are also managed by the credited program. VCSNS determined that biofouling is not an applicable aging effect. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in

Page 68: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 68 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

meeting the intent of the pertinent GALL program.

DG DG Tanks (XTK0053A/B), Fuel Oil Storage

PB Carbon Steel Underground Crevice Corrosion, Pitting Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Buried Piping and Tanks Inspection

See Note A-DG-za

VII.H1.1-b, VII.H1.1.2

T.3-18 Yes, detection of aging effects and operating experience are to be further evaluated.

Partial VII.H1.1-b addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tanks (XTK0009A/B/C/D) - DG Air Reciever

PB Carbon Steel Air-Gas Corrosive Impacts of Alternate Wetting and Drying

Loss of Material Diesel Generator Systems Inspection

See Note A-DG-a See Note A-DG-n

VII.H2.3-a, VII.H2.3.1

T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with this GALL item with respect to material and environment. The identified aging effect is not addressed in the GALL item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tanks (XTK0009A/B/C/D) - DG Air Reciever

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tube & Tube Fittings PB Carbon Steel Air-Gas General Corrosion Loss of Material Diesel Generator Systems Inspection

See Note A-DG-a See Note A-DG-n

VII.H2.3-a, VII.H2.3.1

T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. VCSNS determined that crevice and pitting corrosion were not applicable aging effects. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tube & Tube Fittings PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.1

N.3-05 Yes, detection of aging effects is to be

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The

Page 69: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 69 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

evaluated component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tube & Tube Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tube & Tube Fittings PB Copper Air-Gas None Identified None Identified None Required See Note A-DG-e

N/A N.3-12 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tube & Tube Fittings PB Copper Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-t See Note A-DG-u

N/A N.3-27 N/A N/A The copper and fuel oil combination is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type, are therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

DG DG Tube & Tube Fittings PB Copper Sheltered None Identified None Identified None Required See Note A-DG-h

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tube & Tube Fittings PB Copper Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-DG-zj See Note A-DG-zk

N/A N.3-28 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type, are therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Tube & Tube Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-DG-d

VII.F2.4-a, VII.F2.4.1

T.3-05 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The

Page 70: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 70 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tube & Tube Fittings PB Stainless Steel Oil None Identified None Identified None Required See Note A-DG-s

VIII.G.5-d, VIII.G.5.3

N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-DG-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zh See Note A-DG-zi

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Turbocharger (Casing/Shell Only) (XEG0001A/B-FN1A/B), DG

PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.4-a T.3-05 Yes, plant specific No VII.H2.4-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 71: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 71 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

DG DG Turbocharger (Casing/Shell Only) (XEG0001A/B-FN1A/B), DG

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Valves (Body Only) PB Aluminum Air-Gas None Identified None Identified None Required See Note A-DG-f

N/A N.3-12 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Valves (Body Only) PB Aluminum Sheltered None Identified None Identified None Required See Note A-DG-m

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Valves (Body Only) PB Brass Air-Gas None Identified None Identified None Required See Note A-DG-e

N/A N.3-12 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Valves (Body Only) PB Brass Sheltered None Identified None Identified None Required See Note A-DG-h

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Valves (Body Only) PB Carbon Steel Oil None Identified None Identified None Required See Note A-DG-p

VII.G.7-a, VII.G.7.1

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-DG-b See Note A-DG-c

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in

Page 72: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 72 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-DG-zf See Note A-DG-zg

VII.H2.1-a VII.H2.1.1

T.3-15 No Partial VII.H2.1-a addresses Emergency Diesel Generator System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

DG DG Valves (Body Only) PB Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-DG-y

VII.H1.2-a, VII.H1.2.1

T.3-05 Yes, plant specific No VII.H1.2-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Certain aging effects not addressed by the GALL items are also managed by the credited program. VCSNS determined that loss of material due to crevice and pitting corrosion are not applicable aging effects. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Valves (Body Only) PB Ductile Iron Oil None Identified None Identified None Required See Note A-DG-w

N/A N.3-05 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Valves (Body Only) PB Ductile Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical

See Note A-DG-k

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. In the sheltered

Page 73: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 73 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Components See Note A-DG-l

environment, ductile iron has similarities with carbon steel. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Valves (Body Only) PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-DG-d

VII.F2.4-a, VII.F2.4.1

T.3-05 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-DG-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DN DN Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-0 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DN DN Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-DN-a

V.C.1-b N.2-0 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DN DN Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-DN-b, See Note A-DN-c

V.C.1-b, V.C.1.2

T.2-05 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the

Page 74: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 74 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes of the credited program in effectively managing aging during the period of extended operation.

DN DN Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-0 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DN DN Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-DN-a

V.C.1-b N.2-0 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DN DN Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-DN-b, See Note A-DN-c

V.C.1-b, V.C.1.1

T.2-05 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

EF EF Filter (TPP0008-FL1), EFWP Turbine Lube Oil Filter

PB, FI Aluminum Oil None Identified None Identified None Required See Note A-EF-a

N/A N.4-03 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Filter (TPP0008-FL1), EFWP Turbine Lube Oil Filter

PB, FI Aluminum Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-b See Note A-EF-c

N/A N.4-02 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

EF EF Filter (TPP0008-FL1), EFWP Turbine Lube Oil Filter

PB, FI Carbon Steel Oil None Identified None Identified None Required See Note A-EF-d

VIII.G.5-d, VIII.G.5.1

T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component/component type AMR results for VCSNS are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require

Page 75: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 75 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management during the period of extended operation as detailed in the applicable note.

EF EF Filter (TPP0008-FL1), EFWP Turbine Lube Oil Filter

PB, FI Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activiy for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Heat Exchanger (TPP0008-HE1), EFWP Turbine Lube Oil Cooler - Shell

PB Carbon Steel Oil None Identified None Identified None Required See Note A-EF-d

VIII.G.5-d, VIII.G.5.1

T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component/component type AMR results for VCSNS are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Heat Exchanger (TPP0008-HE1), EFWP Turbine Lube Oil Cooler - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL items which have the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Heat Exchanger (TPP0008-HE1), EFWP Turbine Lube Oil Cooler - Tube

PB, HT Brass Oil None Identified None Identified None Required See Note A-EF-g

VII.G.7-b, VII.G.7.2

N.4-03 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component AMR results are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Heat Exchanger (TPP0008-HE1), EFWP

PB, HT Brass Treated Water

Crevice Corrosion, Galvanic Corrosion,

Loss of Material; Cracking

Chemistry Program, Heat

See Note A-EF-h

VII.C1.3-a, VII.C1.3.1

N.4-06 No No VII.C1.3-a addresses Open-Cycle Cooling Water System components, with

Page 76: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 76 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Turbine Lube Oil Cooler - Tube

Selective Leaching, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Exchanger Inspections

See Note A-EF-ii

microbiologically induced corrosion and biofouling assumed to be a concern only in the raw water environment. Loss of material due to selective leaching was determined not to be an aging effect for this component material-environment combination at VCSNS. Additional aging effects requiring evaluation for VCSNS includes heat exchanger fouling due to particulates and loss of material due to erosion-corrosion. Also, rather than the Open-Cycle Cooling Water System AMP and the Selective Leaching of Materials AMP, all of the applicable aging effects, are managed by the Chemistry Program (which is consistent with GALL XI.M2 but not listed for this GALLitem) and the Heat Exchanger Inspections. The component/component type aging is managed by a program/activity that is not evaluated in GALL Chapter XI, and is therfore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

EF EF Orifices (Breakdown) PB, TH Carbon Steel/Alloy Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel/alloy steel components. The material, environment, aging effect requiring management, and the credited activiy for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Orifices (Breakdown) PB, TH Carbon Steel/Alloy Steel

Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-j See Note A-EF-k

VIII.G.1-c T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.1-c addresses Auxiliary Feedwater System components. The component/component type AMR results for VCSNS are consistent with these GALL items in material, environment, aging effects and program. However, the attributes of the credited program/activity are not fully consistent with the coresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes

Page 77: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 77 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Orifices (Flow) PB, TH Carbon Steel Oil None Identified None Identified None Required See Note A-EF-d

VIII.G.5-d, VIII.G.5.1

T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component/component type AMR results for VCSNS are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Orifices (Flow) PB, TH Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activiy for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Orifices (Flow) PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-EF-x

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Orifices (Flow) PB, TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-l See Note A-EF-m

VIII.G.4-b, VIII.G.4.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.4-b addresses the condensate storage (emergency) tank. The component/component type AMR results are consistent with this GALL item in material, environment, aging effects and program. However, the attributes of the credited program/activity are not fully consistent with the coresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 78: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 78 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. EF EF Pipe and Fittings PB Carbon Steel Reactor

Building Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-n See Note A-EF-o

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL items which have the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activiy for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-j See Note A-EF-k

VIII.G.1-c T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.1-c addresses Auxiliary Feedwater System components. The component/component type AMR results for VCSNS are consistent with these GALL items in material, environment, aging effects and program. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 79: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 79 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

EF EF Pipe and Fittings PB Carbon Steel Yard General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-p See Note A-EF-w

VIII.G.4-c, VIII.G.4.1

T.4-11 No No VIII.G.4-c addresses the condensate storage (emergency) tank (above ground, external surface). The component AMR results for VCSNS are consistent with this GALL item in material, environment and aging effect. However, rather than the Above Ground Carbon Steel Tanks program, loss of material due to general corrosion is managed by a program that is not evaluated in GALL Chapter XI and is therefore specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Pipe and Fittings, EFWP Turbine Lube Oil

PB Carbon Steel Oil None Identified None Identified None Required See Note A-EF-d

VIII.G.5-d, VIII.G.5.1

T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component/component type AMR results for VCSNS are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Pipe and Fittings, EFWP Turbine Lube Oil

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Pipe and Fittings, EFWP Turbine Lube Oil (thermowell)

PB Stainless Steel Oil None Identified None Identified None Required See Note A-EF-q

VIII.G.5-d T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component AMR results are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Pipe and Fittings, EFWP Turbine Lube Oil (thermowell)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-EF-x

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended

Page 80: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 80 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

operation as detailed in the applicable note. EF EF Pump (Casing Only)

(TPP0008-PP1) - EFWP Lube Oil Rotary Pump

PB Cast Iron Oil None Identified None Identified None Required See Note A-EF-r

VIII.G.5-d, VIII.G.5.1

T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component/component type AMR results for VCSNS are consistent with this GALL item in material (cast iron assumed similar to carbon steel) and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Pump (Casing Only) (TPP0008-PP1) - EFWP Lube Oil Rotary Pump

PB Cast Iron Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-s See Note A-EF-t

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes This material/environment combination is not addressed in GALL. However, because of similarities in material properties, the aging effects evaluated for cast iron are the same as those for carbon steel [TR00160-010, Attachment X]. VIII.H.1-a addresses carbon steel components (external surfaces). The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Pump (Casing Only) (XPP0008), EFWP Turbine Driven

PB Alloy Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel/alloy steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Pump (Casing Only) (XPP0008), EFWP Turbine Driven

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-j See Note A-EF-k

VIII.G.1-c T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.1-c addresses Auxiliary Feedwater System components. The component AMR results for VCSNS are consistent with these GALL items in material, environment, aging effects and program. However, the attributes

Page 81: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 81 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Pumps (Casing Only) ( XPP0021A/B), MDEFWP

PB Alloy Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel/alloy steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Pumps (Casing Only) ( XPP0021A/B), MDEFWP

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-j See Note A-EF-k

VIII.G.1-c T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.1-c addresses Auxiliary Feedwater System components. The component/component type AMR results for VCSNS are consistent with these GALL items in material, environment, aging effects and program. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Strainers (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 82: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 82 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

EF EF Strainers (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-l See Note A-EF-m

VIII.G.4-b, VIII.G.4.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.4-b addresses the condensate storage (emergency) tank. The component/component type AMR results are consistent with this GALL item in material, environment, aging effects and program. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Accumulator (TPP0008-OR1), EFWP Turbine Lube Oil Reservoir

PB Carbon Steel Oil None Identified None Identified None Required See Note A-EF-d

VIII.G.5-d, VIII.G.5.1

T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component/component type AMR results for VCSNS are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Accumulator (TPP0008-OR1), EFWP Turbine Lube Oil Reservoir

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-EF-x

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-l See Note A-

VIII.G.4-b, VIII.G.4.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.4-b addresses the condensate storage (emergency) tank. The component/component type AMR results are

Page 83: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 83 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

EF-m consistent with this GALL item in material, environment, aging effects and program. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Tube & Tube Fittings PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.4-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-j See Note A-EF-k

VIII.G.1-c T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.1-c addresses Auxiliary Feedwater System components. The component/component type AMR results for VCSNS are consistent with these GALL items in material, environment, aging effects and program. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and

Page 84: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 84 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

in meeting the intent of the pertinent GALL program.

EF EF Valves (Body Only) PB Carbon Steel Yard General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-p See Note A-EF-w

VIII.G.4-c, VIII.G.4.1

T.4-11 No No VIII.G.4-c addresses the condensate storage (emergency) tank (above ground, external surface). The component AMR results for VCSNS are consistent with this GALL item in material, environment and aging effects. However, rather than the Aboveground Carbon Steel Tanks Program, loss of material due to general corrosion is managed by a program that is not evaluated in GALL Chapter XI and is therefore specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the activity for managing aging during the period of extended operation.

EF EF Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-EF-x

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EF-l See Note A-EF-m

VIII.G.4-b, VIII.G.4.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.4-b addresses the condensate storage (emergency) tank. The component/component type AMR results are consistent with this GALL item in material, environment, aging effects and program. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Valves (Body Only) PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.4-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Valves (Body Only) - EFWP Turbine Lube Oil

PB Brass Oil None Identified None Identified None Required See Note A-EF-g

VII.G.7-b, VII.G.7.2

N.4-03 Yes, detection of aging effects is to be evaluated

Partial VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component AMR results are consistent with this GALL item in material and environment.

Page 85: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 85 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Valves (Body Only) - EFWP Turbine Lube Oil

PB Brass Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-u See Note A-EF-v

N/A N.4-02 N/A N/A Component/Component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Valves (Body Only) - EFWP Turbine Lube Oil

PB Carbon Steel Oil None Identified None Identified None Required See Note A-EF-d

VIII.G.5-d, VIII.G.5.1

T.4-04 Yes, plant specific No VIII.G.5-d addresses bearing oil cooler components. The component/component type AMR results for VCSNS are consistent with this GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

EF EF Valves (Body Only) - EFWP Turbine Lube Oil

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EF-e See Note A-EF-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EX EX Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EX-a, See Note A-EX-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

EX EX Pipe and Fittings PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion

See Note A-EX-c, See

VIII.C.1-a, VIII.C.1.1

T.4-06 No Yes VIII.C.1-a addresses Extraction Steam System piping and fittings. The material,

Page 86: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 86 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Monitoring Program

Note A-EX-d environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EX EX Valves (Body Only) PB Alloy Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EX-a, See Note A-EX-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel/alloy steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EX EX Valves (Body Only) PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EX-c, See Note A-EX-d

VIII.C.1-b, VIII.C.1.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.C.1-b addresses Extraction Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EX EX Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EX-a, See Note A-EX-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring

Page 87: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 87 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EX EX Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EX-c, See Note A-EX-d

VIII.C.1-b, VIII.C.1.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.C.1-b addresses Extraction Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Fire Hydrants PB Cast Iron Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Selective Leaching, Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Fire Hydrants PB Cast Iron Underground Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Buried Piping and Tanks Inspection

See Note A-FS-u

VII.H1.1-b, VII.H1.1.2

T.3-18 Yes, detection of aging effects and operating experience are to be further evaluated.

Partial VII.H1.1-b applies to underground Diesel Fuel Oil piping and fittings. The material for this component/component type is cast iron, where the applicable GALL item material is carbon steel. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item

Page 88: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 88 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

which has a similar environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Fire Hydrants PB Cast Iron Ventilation * None Identified None Identified None Required See Note A-FS-g

N/A N.3-18 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Fire Hydrants PB Cast Iron Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VIII.H.1-b, VIII.H.1.1

T.3-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Flex Hose PB Brass Oil None Identified None Identified None Required See Note A-FS-ii

VII.G.7-b, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Flex Hose PB Brass Sheltered None Identified None Identified None Required See Note A-FS-l, See Note A-FS-m

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Muffler, Diesel Driven Fire Pump Exhaust

NR Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

VII.H2.4-a, VII.H2.4.2

N.3-10 Yes, plant specific No VII.H2.4-a addresses the Emergency Diesel Generator muffler. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for

Page 89: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 89 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Muffler, Diesel Driven Fire Pump Exhaust

NR Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VIII.H.1-b, VIII.H.1.1

T.3-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Nozzles (CO2) TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-FS-n

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Nozzles (CO2) TH Stainless Steel Ventilation * None Identified None Identified None Required See Note A-FS-g

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Nozzles (Filter Plenum) TH Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Nozzles (Filter Plenum) TH Galvanized Steel

Ventilation * None Identified None Identified None Required See Note A-FS-g

VII.F2.1-a, VII.F2.1.2

T.3-05 Yes, plant specific No VII.F2.1-a addresses Ventilation System components. The component/component type AMR results are consistent with the

Page 90: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 90 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Nozzles (Sprinkler) TH Brass Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Nozzles (Sprinkler) TH Brass Raw Water Crevice Corrosion, Galvanic Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion, Selective Leaching; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-c, See Note A-FS-d

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. VCSNS determined that loss of material due to general corrosion is not an aging effect for brass. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Nozzles (Sprinkler) TH Brass Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-l, See Note A-FS-m

N/A T.3-14 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FS FS Orifices PB, TH Stainless Steel Raw Water Crevice Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-e, See Note A-FS-f

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. VCSNS determined that loss of material due to galvanic and general corrosion are not aging effects for stainless steel. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effect and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a

Page 91: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 91 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-FS-n

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Black Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Black Steel Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Black Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Pipe and Fittings PB Carbon Steel Air-Gas (Exhaust)

None Identified None Identified None Required See Note A-FS-q

N/A N.3-10 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of

Page 92: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 92 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Carbon Steel Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-r, See Note A-FS-s

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Pipe and Fittings PB Carbon Steel Ventilation * None Identified None Identified None Required See Note A-FS-g

VII.F2.4-a, VII.F2.4.1

N.3-18 Yes, plant specific No VII.F2.4-a addresses Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging

Page 93: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 93 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an additional aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Cement-lined ductile iron

Raw Water None Identified None Identified None Required See Note A-FS-t

N/A N.3-16 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Cement-lined ductile iron

Underground Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Buried Piping and Tanks Inspection

See Note A-FS-u

VII.H1.1-b, VII.H1.1.2

T.3-18 Yes, detection of aging effects and operating experience are to be further evaluated.

Partial VII.H1.1-b applies to underground Diesel Fuel Oil piping and fittings. The material for this component/component type is ductile iron, where the applicable GALL item material is carbon steel. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Pipe and Fittings PB Galvanized Steel

Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 94: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 94 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Pipe and Fittings PB Iron Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

VII.H2.4-a N.3-04 Yes, plant specific No VII.H2.4-a addresses the Emergency Diesel Generator muffler. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Iron Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an additional aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Stainless Steel Raw Water Crevice Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-e, See Note A-FS-f

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. VCSNS determined loss of material due to galvanic and general corrosion are not aging effects for stainless steel. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effect and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding

Page 95: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 95 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-FS-n

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Pumps (Casing Only) (XPP0134A/B), Electric & Diesel Fire Pump

PB Cast Iron Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Selective Leaching, Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Pumps (Casing Only) (XPP0134A/B), Electric & Diesel Fire Pump

PB Cast Iron Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Strainer (Body Only) PB Carbon Steel Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effect and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a

Page 96: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 96 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Strainer (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Strainer PB, FI Stainless Steel Raw Water Crevice Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-e, See Note A-FS-f

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. VCSNS determined that loss of material due to galvanic and general corrosion are not aging effects for stainless steel. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effect and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Strainer PB, FI Stainless Steel Sheltered None Identified None Identified None Required See Note A-FS-n

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Tank (XTK0125), Fire Service Low Pressure CO2 Storage

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Tank (XTK0125), Fire Service Low Pressure

PB Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical

See Note A-FS-h

VIII.H.1-b, VIII.H.1.1

T.3-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The

Page 97: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 97 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

CO2 Storage Components component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Tank (XTK5028), Diesel Fire Pump Day

PB Carbon Steel Fuel Oil Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Chemistry Program

See Note A-FS-j, See Note A-FS-k

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a applies to Diesel Fuel Oil Tanks. VCSNS determined that loss of material due to biofouling is not an aging effect requiring management. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, aging effect, and credited program (VCSNS Fuel Oil Chemistry included in Chemistry Program). Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Tank (XTK5028), Diesel Fire Pump Day

PB Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VII.H1.4-b, VII.H1.4.2

T.3-23 No No VII.H1.4-b applies to carbon steel tank exterior surfaces. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an additional aging effect requiring management that is not addressed in GALL for this item. VCSNS determined that loss of material due to crevice and pitting corrosion are not applicable aging effects. However, rather than using the Above Ground Carbon Steel Tanks Program to manage the aging effects, a program will be used that is not evaluated in GALL Chapter XI and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

Page 98: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 98 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

FS FS Tube & Tube Fittings PB Brass Oil None Identified None Identified None Required See Note A-FS-ii

VII.G.7-b, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Tube & Tube Fittings PB Brass Sheltered None Identified None Identified None Required See Note A-FS-l, See Note A-FS-m

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Tube & Tube Fittings PB Copper Oil None Identified None Identified None Required See Note A-FS-ii

VII.G.7-b, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Tube & Tube Fittings PB Copper Sheltered None Identified None Identified None Required See Note A-FS-l, See Note A-FS-m

N/A N.3-25 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Tube & Tube Fittings PB Copper Yard Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VII.F1.2-a T.3-05 Yes, plant specific No VII.F1.2-a applies to ventilation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Brass Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Valves (Body Only) PB Brass Oil None Identified None Identified None Required See Note A-FS-ii

VII.G.7-b, VII.G.7.2

N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are

Page 99: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 99 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Valves (Body Only) PB Brass Raw Water Crevice Corrosion, Galvanic Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion, Selective Leaching; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-c, See Note A-FS-d

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. VCSNS determined that loss of material due to general corrosion is not an aging effect for brass. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Brass Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-r, See Note A-FS-s

N/A T.3-14 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Brass Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-l, See Note A-FS-m

N/A T.3-14 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Brass Yard Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FS-h

N/A T.3-05 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII, or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Bronze Air-Gas (Dry) None Identified None Identified None Required See Note A- N/A N.3-04 N/A N/A The material/environment combination for this

Page 100: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 100 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

FS-q component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Valves (Body Only) PB Bronze Raw Water Crevice Corrosion, Galvanic Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-c, See Note A-FS-d

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. VCSNS determined that loss of material due to general corrosion is not an aging effect for bronze. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, aging effect, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Bronze Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-l, See Note A-FS-m

N/A T.3-14 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Valves (Body Only) PB Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-FS-j, See Note A-FS-k

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a applies to Diesel Fuel Oil Tanks. VCSNS determined that loss of material due to crevice, general, and pitting corrosion and loss of material due to biofouling are not aging effects requiring management for components other than tanks. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, aging effect, and credited program (VCSNS Fuel Oil Chemistry included in Chemistry Program).

Page 101: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 101 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Valves (Body Only) PB Carbon Steel Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-r, See Note A-FS-s

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 102: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 102 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Valves (Body Only) PB Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an additional aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Cast Iron Raw Water Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Selective Leaching, Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-a, See Note A-FS-b

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Cast Iron Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FS-o, See Note A-FS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Valves (Body Only) PB Cast Iron Underground Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion

Loss of Material Buried Piping and Tanks Inspection

See Note A-FS-u

VII.H1.1-b, VII.H1.1.2

T.3-18 Yes, detection of aging effects and operating experience are to be further evaluated.

Partial VII.H1.1-b applies to underground Diesel Fuel Oil piping and fittings. The material for this component/component type is cast iron, where the applicable GALL item material is carbon steel. Except as noted, the AMR

Page 103: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 103 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(MIC), Pitting Corrosion

results for this component/component type are consistent with the identified GALL item which has a similar environment, aging effects and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Valves (Body Only) PB Stainless Steel Raw Water Crevice Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Fire Protection Program - Mechanical

See Note A-FS-e, See Note A-FS-f

VII.G.6-b, VII.G.6.2

T.3-21 No Partial VII.G.6-b addresses Fire Protection System components. VCSNS determined that loss of material due to galvanic and general corrosion are not aging effects for stainless steel. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment, aging effect and credited program. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-FS-n

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FW FW Flow Venturi (IFE0476, IFE0486, IFE0496), SG Feedwater Flow

PB, TH Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FW-a See Note A-FW-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 104: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 104 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

FW FW Flow Venturi (IFE0476, IFE0486, IFE0496), SG Feedwater Flow

PB, TH Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-FW-c See Note A-FW-d

VIII.D1.1-a, VIII.D1.1.1

T.4-06 No Yes VIII.D1.1-a addresses Feedwater System piping and fittings. The material, environment, aging effect requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FW FW Flow Venturi (IFE0476, IFE0486, IFE0496), SG Feedwater Flow

TH Nickel-Based Alloy

Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-FW-ii See Note A-FW-j

VIII.G.4-b T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.G.4-b addresses stainless steel emergency feedwater components exposed to treated water. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, aging effects, and credited program . For the purposes of license renewal, particularly with regard to exposure to treated water, nickel-based alloys were conservatively considered to be susceptible to the same aging effects/mechanisms as stainless steel [TR00160-010]. Additionally, certain aging effects (cracking) not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the mitigaion program with a One-time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in generally meeting the intent of the pertinent GALL program.

FW FW Flow Venturi (IFE0476, IFE0486, IFE0496), SG Feedwater Flow

TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-FW-g See Note A-FW-h

VIII.E.4-a, VIII.E.4.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.E.4-a addresses Condensate System heat exchanger components. VCSNS determined that the Chemistry Program will manage loss of material where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, and aging effects. Certain aging

Page 105: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 105 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in generally meeting the intent of the pertinent GALL program.

FW FW Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FW-e See Note A-FW-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FW FW Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FW-a See Note A-FW-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FW FW Pipe and Fittings PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-FW-c See Note A-FW-d

VIII.D1.1-a, VIII.D1.1.1

T.4-06 No Yes VIII.D1.1-a addresses Feedwater System piping and fittings. The material, environment, aging effect requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the

Page 106: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 106 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FW FW Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-FW-k

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FW FW Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-FW-g See Note A-FW-h

VIII.E.4-a, VIII.E.4.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.E.4-a addresses Condensate System heat exchanger components. VCSNS determined that the Chemistry Program will manage loss of material where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FW FW Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-FW-a See Note A-FW-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the

Page 107: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 107 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FW FW Valves (Body Only) PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-FW-c See Note A-FW-d

VIII.D1.2-a, VIII.D1.2.1

T.4-06 No Yes VIII.D1.2-a addresses Feedwater System valve bodies. The material, environment, aging effect requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FW FW Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-FW-k

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FW FW Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-FW-g See Note A-FW-h

VIII.E.4-a, VIII.E.4.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.E.4-a addresses Condensate System heat exchanger components. VCSNS determined that the Chemistry Program will manage loss of material where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

GS GS Pipe and Fittings PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow-Accelerated Corrosion

See Note A-GS-a, See

VIII.B1.1-c, VIII.B1.1.3

T.4-06 No Yes VIII.B1.1-c addresses Main Steam System piping and fittings. The material, environment,

Page 108: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 108 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Monitoring Program

Note A-GS-b aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

GS GS Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-GS-a, See Note A-GS-b

VIII.B1.1-a, VIII.B1.1.2

T.4-07 No Yes VIII.B1.1-a addresses Main Steam System piping and fittings. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

GS GS Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-GS-c, See Note A-GS-d

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

GS GS Valves (Body Only) PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow-Accelerated Corrosion Monitoring Program

See Note A-GS-a, See Note A-GS-b

VIII.B1.2-b, VIII.B1.2.1

T.4-06 No Yes VIII.B1.1-c addresses Main Steam System valve bodies. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the

Page 109: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 109 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

HR HR Pipe and Fittings PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-HR-g

N/A N.2-02 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-HR-a See Note A-HR-b

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses carbon steel component exterior surfaces. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

HR HR Pipe and Fittings PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-HR-f

N/A N.2-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-HR-e

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Recombiners (XHR0004A/B) - Electric, H2

HT Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-HR-c See Note A-HR-d

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in

Page 110: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 110 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

HR HR Recombiners (XHR0004A/B) - Electric, H2

HT Nickel-Based Alloy (Inconel 600)

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

N/A N.2-03 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Recombiners (XHR0004A/B) - Electric, H2

HT Nickel-Based Alloy (Incoloy 800)

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

N/A N.2-03 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Recombiners (XHR0004A/B) - Electric, H2

HT Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Tube & Tube Fittings PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-HR-f

N/A N.2-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-HR-e

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 111: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 111 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

HR HR Valves (Body Only) PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-HR-g

N/A N.2-02 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-HR-a See Note A-HR-b

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

HR HR Valves (Body Only) PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-HR-f

N/A N.2-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

HR HR Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-HR-e

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Pipe and Fittings PB Carbon Steel Air-Gas General Corrosion Loss of Material Service Air System Inspection

See Note A-IA-a See Note A-IA-r

VII.H2.3-a, VII.H2.3.1

N.3-13 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, except that VCSNS determined that loss of material due to crevice and pitting corrosion were not applicable aging effects. The credited activity will manage the aging effect and the identified GALL item recommends plant specific evaluation of the credited

Page 112: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 112 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. The component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-c See Note A-IA-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-e See Note A-IA-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Pipe and Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-IA-g

N/A N.3-13 N/A N/A The material/environment (dry air) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require

Page 113: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 113 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management during the period of extended operation as detailed in the applicable note.

IA IA Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-IA-h

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL items recommend plant specific evaluation of the creditied program. Refer to TR00160-020 for a detailed discussion of the attributes of this credited activity in effectively managing aging during the period of extended operation.

IA IA Tanks PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-IA-a

N/A N.3-13 N/A N/A The material/environment (dry air) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Tanks PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-e See Note A-IA-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Tube & Tube Fittings PB Copper Air-Gas None Identified None Identified None Required See Note A-IA-j

N/A N.3-13 N/A N/A The material/environment (dry air) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Tube & Tube Fittings PB Copper Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-k See Note A-IA-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. VCSNS uses the same AMP (BAC Surveillances) for the external surfaces of carbon steel and copper. Therefore, the material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment,

Page 114: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 114 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Tube & Tube Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-IA-g

N/A N.3-13 N/A N/A The material/environment (dry air) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Tube & Tube Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-IA-h

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this credited activity in effectively managing aging during the period of extended operation.

IA IA Valves (Body Only) PB Aluminum Air-Gas None Identified None Identified None Required See Note A-IA-l

N/A N.3-13 N/A N/A The material/environment (dry air) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Valves (Body Only) PB Aluminum Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-m See Note A-IA-q

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. VCSNS uses the same AMP (BAC Surveillances) for the external surfaces of carbon steel and aluminum. Therefore, the material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 115: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 115 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. IA IA Valves (Body Only) PB Brass Air-Gas None Identified None Identified None Required See Note A-

IA-j N/A N.3-13 N/A N/A The material/environment (dry air)

combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Valves (Body Only) PB Brass Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-k See Note A-IA-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. VCSNS uses the same AMP (BAC Surveillances) for the external surfaces of carbon steel and brass. Therefore, the material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Valves (Body Only) PB Carbon Steel Air-Gas General Corrosion Loss of Material Service Air System Inspection

See Note A-IA-a See Note A-IA-r

VII.H2.3-a, VII.H2.3.1

N.3-13 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, except that VCSNS determined that loss of material due to crevice and pitting corrosion were not applicable aging effects. The credited activity will manage the aging effect and the identified GALL item recommends plant specific evaluation of the credited program. The component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-c See Note A-IA-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes

Page 116: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 116 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-e See Note A-IA-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Valves (Body Only) PB Cast Iron Air-Gas None Identified None Identified None Required See Note A-IA-n

N/A N.3-13 N/A N/A The material/environment (dry air) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Valves (Body Only) PB Cast iron Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-IA-b See Note A-IA-o

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging effects as carbon steel. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

IA IA Valves (Body Only) PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-IA-g

N/A N.3-13 N/A N/A The material/environment (dry air) combination for this component/component

Page 117: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 117 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

IA IA Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-IA-h

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1b IC Incore Neutron Detector (Flux) Thimbles (XD0004-IC) - Bottom Mounted Instrumentation

4, 7 Stainless Steel (Type 304)

Borated Water

Wear Loss of Material Bottom Mounted Instrumentation Inspection

See Note A-RC1b-f.

IV.B2.6-c, IV.B2.6.2

T.1-40 No Partial The Bottom Mounted Instrumentation Inspection is not a program listed separately in GALL. However, the GALL item specifies the ASME Section XI (XI.M1) program as well as recommendations of NRC Bulletin 88-09 for management with no further evaluation recommended. The GALL item also briefly describes the recommendations that are to be included in the credited AMP. The sub-component AMR results are consistent with the identified GALL item in material, environment, and aging effect requiring management. Also, the credited program, in response to IE Bulletin 88-09, is considered sufficient for aging management with no reliance on IWB, IWC or IWD Inservice Inspections. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing the aging effect during the period of extended operation. Lastly, the attributes of the credited program meet the intent of the description provided for the GALL item, although the inspection frequency may or may not correspond to the GALL example, but is in accordance with the VCSNS CLB.

LR LR Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-LR-a See Note A-LR-b

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent

Page 118: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 118 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

LR LR Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-LR-c See Note A-LR-d

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

LR LR Pipe and Fittings PB Carbon Steel Ventilation * None Identified None Identified None Required See Note A-LR-e

V.C.1-a, V.C.1.2

T.2-03, T.2-05

Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

LR LR Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-LR-c See Note A-LR-d

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

LR LR Valves (Body Only) PB Carbon Steel Ventilation * None Identified None Identified None Required See Note A- V.C.1-a, T.2-03, Yes, plant specific No V.C.1-a addresses containment isolation

Page 119: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 119 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

LR-e V.C.1.1 T.2-05 components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MB MB Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MB-a, See Note A-MB-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MB MB Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-MB-c, See Note A-MB-d

VIII.B1.1-a, VIII.B1.1.2

T.4-07 No Yes VIII.B1.1-a addresses Main Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MB MB Tube & Tube Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MB-a, See Note A-MB-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a

Page 120: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 120 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MB MB Tube & Tube Fittings PB Carbon Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-MB-c, See Note A-MB-d

VIII.B1.1-a, VIII.B1.1.2

T.4-07 No Yes VIII.B1.1-a addresses Main Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MB MB Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MB-a, See Note A-MB-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MB MB Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-MB-c, See Note A-MB-d

VIII.B1.2-a, VIII.B1.2.1

T.4-07 No Yes VIII.B1.2-a addresses Main Steam System valve bodies. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to

Page 121: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 121 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS EF Turbine (Casing/Shell Only) (TPP0008), EFWP

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MS-a, See Note A-MS-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS EF Turbine (Casing/Shell Only) (TPP0008), EFWP

PB Carbon Steel Ventilation * General Corrosion Loss of Material Preventive Maintenance Activities - Terry Turbine

See Note A-MS-m, See Note A-MS-n

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Note that the ventilation* environment is ambient building air (i.e., sheltered environment) contained within the MS System components. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS MS Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MS-e, See Note A-MS-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion Loss of Material Boric Acid See Note A- VIII.H.1-a, T.4-13 No Yes VIII.H.1-a addresses external surfaces of

Page 122: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 122 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(Aggressive Chemical Attack)

Corrosion Surveillances

MS-a, See Note A-MS-b

VIII.H.1.1 carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-MS-c, See Note A-MS-d

VIII.B1.1-a, VIII.B1.1.2

T.4-07 No Yes VIII.B1.1-a addresses Main Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS EF Valve (Body Only) (XVM11025-EF), EFWP Turbine Governor

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MS-a, See Note A-MS-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS EF Valve (Body Only) (XVM11025-EF), EFWP Turbine Governor

PB Carbon Steel Ventilation * General Corrosion Loss of Material Preventive Maintenance Activities - Terry

See Note A-MS-m, See Note A-MS-n

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are

Page 123: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 123 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Turbine consistent with the identified GALL item in material, environment, and aging effect. Note that the ventilation* environment is ambient building air (i.e., sheltered environment) contained within the MS System components. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS MS Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MS-e, See Note A-MS-f

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-MS-c, See Note A-MS-d

VIII.B1.2-a, VIII.B1.2.1

T.4-07 No Yes VIII.B1.2-a addresses Main Steam System valve bodies. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.4-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended

Page 124: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 124 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

operation as detailed in the applicable note. MS MS Valves (Body Only) PB Stainless Steel Treated

Water Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-MS-g, See Note A-MS-h

V.A.4-a, V.A.4.1

N.4-05 No Partial V.A.4-a addresses Containment Spray System components. The component/component type AMR results are consistent with the identified GALL item in material, aging effect and aging management program. Relative to the environment, the identified GALL item references chemically treated borated water, while the component/component type AMR results consider treated water. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

MU MU Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-MU-c

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MU MU Orifices PB, TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-MU-a See Note A-MU-b

V.A.1-a, V.A.1.2

N.3-17 No Partial V.A.1-a addresses Containment Spray System piping and fittings. The component/component type AMR results are consistent with the identified GALL items in material, aging effect/mechanism and aging management program. Relative to the environment, the identified GALL items reference chemically treated borated water, while the component/component type AMR results consider treated water. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

MU MU Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Loss of Material Maintenance Rule See Note A- V.C.1-b, N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation

Page 125: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 125 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Induced Corrosion (MIC)

Structures Program

MU-c V.C.1.2 components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

MU MU Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-MU-a See Note A-MU-b

V.A.1-a, V.A.1.1

N.3-17 No Partial V.A.1-a addresses Containment Spray System piping and fittings. The component/component type AMR results are consistent with the identified GALL items in material, aging effect/mechanism and aging management program. Relative to the environment, the identified GALL items reference chemically treated borated water, while the component/component type AMR results consider treated water. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

MU MU Pipe and Fittings PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MU MU Pumps (Casing Only) (XPP0040A/B), Reactor Makeup Water

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-MU-c

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MU MU Pumps (Casing Only) (XPP0040A/B), Reactor Makeup Water

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-MU-a See Note A-MU-b

V.A.3-a, V.A.3.1

N.3-17 No Partial V.A.3-a addresses Containment Spray System pump casings. The component/component type AMR results are consistent with the identified GALL items in material, aging effect/mechanism and aging management program. Relative to the

Page 126: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 126 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

environment, the identified GALL items reference chemically treated borated water, while the component/component type AMR results consider treated water. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

MU MU Tank (XTK0039), Reactor Makeup Water Storage

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion, Corrosive Impacts of Alternate Wetting and Drying; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; Above Ground Tank Inspection

See Note A-MU-a See Note A-MU-b

V.D1.8-a, V.D1.8.1

N.3-20 No Partial V.D1.8-a addresses the Refueling Water Storage Tank. The component/component type AMR results are consistent with the identified GALL item in material, aging effect/mechanism and aging management program as clarified. Relative to the environment, the identified GALL item references chemically treated borated water, while the component/component type AMR results address treated water, with no boric acid. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meets the intent of the corresponding GALL Chapter XI program (XI.M1) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL Program. In addition, the Above Ground Tank Inspection, a one-time internal inspection not to be confused with GALL program XI.M29, "Above Ground Carbon Steel Tanks", an inspection of inaccessible areas of external tank surfaces, is credited with supplementing the Chemistry Program to detect and characterize the affects of aging (loss of material and/or cracking) due to alternate wetting and drying. Refer to TR00160-020 for a detailed discussion of this activity.

MU MU Tank (XTK0039), Reactor Makeup Water

PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed

Page 127: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 127 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Storage for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MU MU Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-MU-c

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MU MU Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-MU-a See Note A-MU-b

V.A.1-a, V.A.1.1

N.3-17 No Partial V.A.1-a addresses Containment Spray System piping and fittings. The component/component type AMR results are consistent with the identified GALL items in material, aging effect/mechanism and aging management program. Relative to the environment, the identified GALL items reference chemically treated borated water, while the component/component type AMR results consider treated water. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

MU MU Tube & Tube Fittings PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MU MU Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-MU-c

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MU MU Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program

See Note A-MU-a See Note A-

V.A.4-a, V.A.4.1

N.3-17 No Partial V.A.1-a addresses Containment Spray System valve bodies. The component/component type AMR results are

Page 128: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 128 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC) MU-b consistent with the identified GALL items in material, aging effect/mechanism and aging management program. Relative to the environment, the identified GALL items reference chemically treated borated water, while the component/component type AMR results consider treated water. TR00160-010 defines a borated water environment as demineralized water treated with boric acid. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

MU MU Valves (Body Only) PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

ND ND Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Liquid Waste System Inspection

See Note A-ND-a See Note A-ND-b

V.D1.1-a, V.D1.1.2

N.3-21 No No V.D1.1-a addresses ECCS piping and fitting internal surfaces in contact with borated water. The component AMR results are consistent with this GALL item # in material and environment. Certain aging effects not addressed by the GALL item are also managed by the credited activity. The GALL aging effect is stress corrosion cracking, which is not applicable to the ND System. The VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion and they will be managed by the Liquid Waste System Inspection. Component/component type is managed by an activity that is not evaluated in GALL Chapter XI and is, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

ND ND Pipe and Fittings PB Stainless Steel Embedded None Identified None Identified None Required Pipe is embedded in the Reactor Building. Also, see TR00160-010, Attachment #

N/A N.3-08 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 129: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 129 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VIII ND ND Pipe and Fittings PB Stainless Steel Reactor

Building None Identified None Identified None Required TR00160-010,

Attachment IXV.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation

components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

ND ND Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-ND-d

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

ND ND Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Liquid Waste System Inspection

See Note A-ND-a See Note A-ND-b

V.D1.1-a, V.D1.1.2

N.3-21 No No V.D1.1-a addresses ECCS piping and fitting internal surfaces in contact with borated water. The component AMR results are consistent with this GALL item # in material and environment. Certain aging effects not addressed by the GALL item are also managed by the credited activity. The GALL aging effect is stress corrosion cracking, which is not applicable to the ND System. The VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion and they will be managed by the Liquid Waste System Inspection. Component/component type is managed by an activity that is not evaluated in GALL Chapter XI and is, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

ND ND Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

ND ND Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended

Page 130: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 130 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

operation as detailed in the applicable note. NG NG Pipe and Fittings PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-

NG-c V.C.1-a, V.C.1.1

T.2-03, T.2-05

Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

NG NG Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-NG-a See Note A-NG-b

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

NG NG Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-NG-d See Note A-NG-e

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

NG NG Valves (Body Only) PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-NG-c

V.C.1-a, V.C.1.1

T.2-03, T.2-05

Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

NG NG Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-NG-a See Note A-

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring

Page 131: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 131 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

NG-b management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

NG NG Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-NG-d See Note A-NG-e

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RD RD Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Reactor Building Cooling Unit Inspection

See Note A-RD-a See Note A-RD-b

V.A.1-a, V.A.1.1

N.3-22 No No GALL Item Nos. V.A.1-a and V.A.1.1 address piping, fittings and miscellaneous items, and piping and fittings up to isolation valve, respectively. The aging effects for the component/component type are managed by an activity that is not evaluated in GALL Chapter XI and is, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

RD RD Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Heat Exchangers (XHE0005A/B), RHR - Channel Head

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a, See Note A-RH-b

V.D1.5-a, V.D1.5.1

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in

Page 132: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 132 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. An additional VCSNS AMR aging effect is cracking due to stress corrosion (SCC), which is also managed with the referenced programs. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XHE0005A/B), RHR - Channel Head

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Heat Exchangers (XHE0005A/B), RHR - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-RH-e See Note A-RH-h

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XHE0005A/B), RHR - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RH-c See Note A-RH-d

V.D1.5-a, V.D1.5.3

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Additional VCSNS AMR aging effects are general and galvanic corrosion, which are also managed with the referenced programs. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of

Page 133: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 133 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation. RH RH Heat Exchangers

(XHE0005A/B), RHR - Tubes

PB, HT Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.5-a, V.D1.5.2

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. An additional VCSNS AMR aging effect is cracking due to stress corrosion (SCC), which is also managed with the referenced programs. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XHE0005A/B), RHR - Tubes

PB, HT Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RH-f See Note A-RH-g

V.D1.5-a, V.D1.5.2

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XHE0005A/B), RHR - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.5-a, V.D1.5.1

T.2-13 No Partial V.D1.5-a addresses ECCS heat exchanger internal surfaces. The component/component type AMR results are consistent with this GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. An additional VCSNS AMR aging effect is cracking due to stress corrosion, which is also managed with the referenced programs. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 134: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 134 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XHE0005A/B), RHR - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RH-f See Note A-RH-g

V.D1.5-a, V.D1.5.1

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XPP0031A/B-HE1), RH Pump Seal - Head

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment # X

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Heat Exchangers (XPP0031A/B-HE1), RH Pump Seal - Head

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RH-f See Note A-RH-g

V.D1.5-a, V.D1.5.1

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XPP0031A/B-HE1), RH Pump Seal - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-RH-e See Note A-RH-h

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during

Page 135: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 135 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the period of extended operation. RH RH Heat Exchangers

(XPP0031A/B-HE1), RH Pump Seal - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RH-c See Note A-RH-d

V.D1.5-a, V.D1.5.3

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Additional VCSNS AMR aging effects are loss of material due to general and galvanic corrosion, which are also managed with the referenced programs. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XPP0031A/B-HE1), RH Pump Seal - Tubes

PB, HT Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.5-a, V.D1.5.2

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. An additional VCSNS AMR aging effect is cracking due to stress corrosion (SCC), which is also managed with the referenced programs. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XPP0031A/B-HE1), RH Pump Seal - Tubes

PB, HT Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RH-f See Note A-RH-g

V.D1.5-a, V.D1.5.2

T.2-13 No Partial V.D1.5-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. The Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. However, the attributes of the credited program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the

Page 136: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 136 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes of this program/activity in effectively managing aging during the period of extended operation.

RH RH Orifices PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.1-a, V.D1.1.2

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and credited program. However, additional VCSNS AMR aging effects requiring management include loss of material due to crevice and pitting corrosion, which are also managed with the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RH RH Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.1-a, V.D1.1.2

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and credited program. However, additional VCSNS AMR aging effects requiring management include loss of material due to crevice and pitting corrosion, which are also managed with the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RH RH Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging

Page 137: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 137 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RH-j

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Pumps (Casing Only) (XPP0031A/B), RHR

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.2-a, V.D1.2.1

T.2-15 No Yes V.D1.2-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and credited program. However, additional VCSNS AMR aging effects requiring management include loss of material due to crevice and pitting corrosion, which are also managed with the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RH RH Pumps (Casing Only) (XPP0031A/B), RHR

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.1-a, V.D1.1.2

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and credited program. However, additional VCSNS AMR aging effects requiring management include loss of material due to crevice and pitting corrosion, which are also managed with the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively

Page 138: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 138 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RH RH Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RH-j

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RH-a See Note A-RH-b

V.D1.4-b, V.D1.4.1

T.2-15 No Yes V.D1.4-b addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and credited program. However, additional VCSNS AMR aging effects requiring management include loss of material due to crevice and pitting corrosion, which are also managed with the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RH RH Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RH RH Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RM RM Instrumentation (Pressure Retaining Only) - (RML0002A/B)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-a See Note A-RM-b

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will sufficiently manage loss of material for this component/component type, where the applicable GALL program is "Closed-Cycle Cooling Water System." Except as noted, the

Page 139: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 139 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of a GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RM RM Instrumentation (Pressure Retaining Only) - (RML0001, RML0002A/B, RML0004)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RM-e

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RM RM Instrumentation (Pressure Retaining Only) - (RML0001, RML0004)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-c See Note A-RM-d

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RM RM Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-c See Note A-RM-d

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program

Page 140: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 140 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RM RM Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-RM-e

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

RM RM Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-a See Note A-RM-b

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will sufficiently manage loss of material for this component/component type, where the applicable GALL program is "Closed-Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RM RM Tanks (RML0001-TK1, RML0004-TK1)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-c See Note A-RM-d

V.D1.8-a, V.D1.8.1

N.3-06 No Yes V.D1.8-a addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in

Page 141: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 141 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

meeting the intent of the pertinent GALL program.

RM RM Tanks (RML0001-TK1, RML0002A,B-TK1, RML0004-TK1)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RM-e

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RM RM Tanks (RML0002A,B-TK1)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-a See Note A-RM-b

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will sufficiently manage loss of material for this component/component type, where the applicable GALL program is "Closed-Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of a GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RM RM Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-c See Note A-RM-d

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RM RM Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RM-e

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging

Page 142: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 142 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects were determined to require management during the period of extended operation as detailed in the applicable note.

RM RM Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-a See Note A-RM-b

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will sufficiently manage loss of material for this component/component type, where the applicable GALL program is "Closed-Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of the credited program meet the intent of a GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RM RM Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-c See Note A-RM-d

V.D1.4-b, V.D1.4.1

N.3-06 No Yes V.D1.4-b addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RM RM Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RM-e

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RM RM Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RM-a See Note A-RM-b

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will sufficiently manage loss of material for this

Page 143: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 143 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

component/component type, where the applicable GALL program is "Closed-Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SA SA Pipe and Fittings PB Carbon Steel Air-Gas General Corrosion Loss of Material Service Air System Inspection

See Note A-SA-a See Note A-SA-b

VII.H2.3-a, VII.H2.3.1

N.3-14 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, except that VCSNS determined that loss of material due to crevice and pitting corrosion were not applicable aging effects. The credited activity will manage the aging effect and the identified GALL item recommends plant specific evaluation of the credited program. The component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SA SA Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SA-c See Note A-SA-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SA SA Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SA-e See Note A-SA-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent

Page 144: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 144 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SA SA Tube & Tube Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-SA-g

VII.F2.4-a, VII.F2.4.1

T.3-05 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SA SA Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SA SA Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SA-h

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SA SA Valves (Body Only) PB Carbon Steel Air-Gas General Corrosion Loss of Material Service Air System Inspection

See Note A-SA-a See Note A-SA-b

VII.H2.3-a, VII.H2.3.1

N.3-14 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, except that VCSNS determined that loss of material due to crevice and pitting corrosion were not applicable aging effects. The credited activity will manage the aging effect and the identified GALL item recommends plant specific evaluation of the credited program. The component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 145: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 145 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation.

SA SA Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SA-c See Note A-SA-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SA SA Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SA-e See Note A-SA-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SA SA Valves (Body Only) PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-SA-g

VII.F2.4-a, VII.F2.4.1

T.3-05 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identifed GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SA SA Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SA SA Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A- V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation

Page 146: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 146 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

SA-h components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Heat Exchangers (XHE0007A/B), SFC - Channel Head

PB Carbon Steel/Stainless Steel Combination

Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-a, See Note A-SF-b

V.D1.6-a, V.D1.6.1

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SF SF Heat Exchangers (XHE0007A/B), SFC - Channel Head

PB Carbon Steel/Stainless Steel Combination

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SF-d, See Note A-SF-e

V.D1.5-b, V.D1.5.3

T.3-14 No Yes V.D1.5-b addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI activity attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Heat Exchangers (XHE0007A/B), SFC - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SF-d, See Note A-SF-e

V.D1.5-b, V.D1.5.3

T.3-14 No Yes V.D1.5-b addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI activity

Page 147: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 147 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Heat Exchangers (XHE0007A/B), SFC - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-h, See Note A-SF-ii

V.D1.6-a, V.D1.6.3

T.3-15 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for carbon steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SF SF Heat Exchangers (XHE0007A/B), SFC - Tubes

PB, HT Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-c, See Note A-SF-b

V.D1.5-a, V.D1.5.2

N.3-06 No Partial V.D1.5-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for stainless steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SF SF Heat Exchangers (XHE0007A/B), SFC - Tubes

PB, HT Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-f, See Note A-SF-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as

Page 148: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 148 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SF SF Heat Exchangers (XHE0007A/B), SFC - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-c, See Note A-SF-b

V.D1.5-a, V.D1.5.2

N.3-06 No Partial V.D1.5-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for stainless steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SF SF Heat Exchangers (XHE0007A/B), SFC - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-f, See Note A-SF-g

V.D1.5-a, V.D1.5.2

T.3-15 No Partial V.D1.5-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program will manage loss of material for stainless steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

Page 149: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 149 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

SF FH Nuclear Fuel Handling Equipment and Fixtures (XNF0008-FH) - Fuel Transfer Tube

PB Stainless Steel Embedded None Identified None Identified None Required TR00160-010, Attachment VIII

N/A N.3-08 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII, or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF FH Nuclear Fuel Handling Equipment and Fixtures (XNF0008-FH) - Fuel Transfer Tube

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SF-k

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF FH Nuclear Fuel Handling Equipment and Fixtures (XNF0008-FH) - Fuel Transfer Tube

PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-SF-j

VII.F3.4-a N.3-01 Yes, plant specific No VII.F3.4-a addresses Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Orifices PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-c, See Note A-SF-b

VII.A3.3-b, VII.A3.3.1

T.3-13 No Partial VII.A3.3-b addresses Spent Fuel Pool Cooling and Cleanup System components. VCSNS determined that cracking due to stress corrosion cracking is not an aging effect requiring management for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL Item, which has a similar material, environment and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-SF-k

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 150: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 150 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

SF RW Pipe and Fittings (RW) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-c, See Note A-SF-b

V.D1.1-a, V.D1.1.6

T.2-15 No Partial V.D1.1-a addresses Emergency Core Cooling System piping and fitting internal surfaces. VCSNS determined that cracking due to stress corrosion cracking is not an aging effect requiring management for this component. Except as noted, the AMR results for this component/component type are consistent with the identified GALL Item which has a similar material, environment, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Pipe and Fittings (SF) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-c, See Note A-SF-b

VII.A3.3-b, VII.A3.3.1

T.3-13 No Partial VII.A3.3-b addresses Spent Fuel Pool Cooling and Cleanup System components. VCSNS determined that cracking due to stress corrosion cracking is not an aging effect requiring management for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL Item, which has a similar material, environment and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-SF-l

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the

Page 151: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 151 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

identified GALL item in material, environment and aging effects (except that VCSNS found that loss of material due to crevice and pitting corrosion are not aging effects for stainless steel exposed to ambient air). However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SF SF Pipe and Fittings PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-SF-j

VII.F3.4-a N.3-01 Yes, plant specific No VII.F3.4-a addresses Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF RW Pipe and Fittings (RW) PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.2-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII, or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Pipe and Fittings (SF) PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII, or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Pumps (Casing Only) (XPP0032A/B), Spent Fuel

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-c, See Note A-SF-b

VII.A3.3-b, VII.A3.3.1

T.3-13 No Partial VII.A3.3-b addresses Spent Fuel Pool Cooling and Cleanup System components. VCSNS determined that cracking due to stress corrosion cracking is not an aging effect requiring management for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL Item, which has a similar material, environment and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in

Page 152: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 152 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

meeting the intent of the pertinent GALL program.

SF SF Pumps (Casing Only) (XPP0032A/B), Spent Fuel

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SF-k

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF RW Tank (XTK0025), Refueling Water Storage (RWST)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Corrosive Impacts of Alternate Wetting and Drying

Loss of Material; Loss of Material/Cracking

Chemistry Program; Above Ground Tank Inspection

See Note A-SF-c, See Note A-SF-b

V.D1.8-a, V.D1.8.1

N.2-07 No No V.D1.8-a addresses cracking of the Refueling Water Storage Tank internal surfaces (V.D1.8.1). Although the component/component type AMR results are consistent with the identified GALL item in material, environment, and aging management program as clarified, VCSNS determined that cracking due to stress corrosion cracking is not an aging effect requiring management for this component, as described in the referenced note, except as clarified. Rather, the Chemistry Program is credited for managing the aging due to crevice and pitting corrosion (not identified as valid aging mechanisms for the GALL item). The attributes of the credited program meet the intent of the identified GALL program (XI.M1). Refer to TR00160-020 for a detailed discussion of the attributes of this program in managing the effects of aging during the period of extended operation and in meeting the intent of the pertinent GALL program. In addition, the Above Ground Tank Inspection, a one-time internal inspection not to be confused with GALL program XI.M29, "Above Ground Carbon Steel Tanks", an inspection of inaccessible areas of external tank surfaces, is credited with supplementing the Chemistry Program to detect and characterize the affects of aging (loss of material and/or cracking) due to alternate wetting and drying. Refer to TR00160-020 for a detailed discussion of this activity.

SF RW Tank (XTK0025), Refueling Water Storage (RWST)

PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.2-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII, or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Tube & Tube Fittings PB Stainless Steel Borated Crevice Corrosion, Loss of Material Chemistry See Note A- VII.A3.3-b, T.3-13 No Partial VII.A3.3-b addresses Spent Fuel Pool

Page 153: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 153 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Water Pitting Corrosion Program SF-c, See Note A-SF-b

VII.A3.3.1 Cooling and Cleanup System components. VCSNS determined that cracking due to stress corrosion cracking is not an aging effect requiring management for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL Item, which has a similar material, environment and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SF-k

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Tube & Tube Fittings PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII, or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SF-c, See Note A-SF-b

VII.A3.3-b, VII.A3.3.1

T.3-13 No Partial VII.A3.3-b addresses Spent Fuel Pool Cooling and Cleanup System components. VCSNS determined that cracking due to stress corrosion cracking is not an aging effect requiring management for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL Item, which has a similar material, environment and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 154: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 154 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SF-k

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Valves (Body Only) PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-SF-j

VII.F3.4-a N.3-01 Yes, plant specific No VII.F3.4-a addresses Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF SF Valves (Body Only) PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, Attachment XII

N/A N.3-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII, or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Orifices PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SI-a See Note A-SI-b

V.D1.1-a, V.D1.1.3

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent

Page 155: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 155 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the pertinent GALL program. SI SI Orifices PB, TH Stainless Steel Borated

Water Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SI-a See Note A-SI-b

V.D1.1-a, V.D1.1.3

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Orifices PB, TH Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-SI-ii

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Pipe and Fittings PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-SI-h

N/A N.2-02 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SI-a See Note A-SI-b

V.D1.1-a, V.D1.1.3

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program.

Page 156: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 156 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SI-ii

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Tanks (XTK0028A/B/C), SI Accumulator

PB Stainless Steel Cladding

Air-Gas (Moist)

None Identified None Identified None Required See Note A-SI-h

N/A N.2-01 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Tanks (XTK0028A/B/C), SI Accumulator

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SI-e See Note A-SI-f

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Tanks (XTK0028A/B/C), SI Accumulator

PB Stainless Steel Cladding

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SI-a See Note A-SI-b

V.D1.7-b, V.D1.7.3

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent

Page 157: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 157 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SI-a See Note A-SI-b

V.D1.1-a, V.D1.1.3

T.2-15 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SI-ii

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Tube & Tube Fittings PB Stainless Steel Treated Water

None Identified None Identified None Required See Note A-SI-d

V.C.1-b N.2-06 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging

Page 158: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 158 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Valves (Body Only) PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-SI-g

N/A N.2-02 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SI-e See Note A-SI-f

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Valves (Body Only) PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-SI-h

N/A N.2-02 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SI-a See Note A-SI-b

V.D1.4-b, V.D1.4.1

T.2-15 No Yes V.D1.4-b addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Valves (Body Only) PB Stainless Steel Reactor None Identified None Identified None Required TR00160-010, V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation

Page 159: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 159 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Building Attachment IX components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Valves (Body Only) PB Stainless Steel Treated Water

None Identified None Identified None Required See Note A-SI-d

V.C.1-b N.2-06 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Orifices PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-a See Note A-SP-b

V.A.1-a, V.A.1.2

T.2-15 No Yes V.A.1-a addresses Containment Spray System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SP SP Orifices PB, TH Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-SP-l

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Orifices PB, TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program

See Note A-SP-c See Note A-

VII.C2.2-a, VII.C2.2.1

N.2-05 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are

Page 160: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 160 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC) SP-d consistent with the identified GALL items in material, environment, and aging effect/mechanisms. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SP SP Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SP-e See Note A-SP-f

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SP SP Pipe and Fittings PB Carbon Steel Yard General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SP-ii See Note A-SP-j

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SP SP Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-a See Note A-SP-b

V.A.1-a, V.A.1.1

T.2-15 No Yes V.A.1-a addresses Containment Spray System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also

Page 161: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 161 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SP SP Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SP-l

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-c See Note A-SP-d

VII.C2.2-a, VII.C2.2.1

N.2-05 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SP SP Pipe and Fittings PB Stainless Steel Ventilation * None Identified None Identified None Required TR00160-010, Attachment IX

N/A N.2-01 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Pipe and Fittings PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation

Page 162: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 162 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Attachment XII components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Pumps (Casing Only) (XPP0038A/B), Reactor Building Spray

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-a See Note A-SP-b

V.A.3-a, V.A.3.1

T.2-15 No Yes V.A.3-a addresses Containment Spray System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SP SP Pumps (Casing Only) (XPP0038A/B), Reactor Building Spray

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SP-l

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Tank (XTK0060), Sodium Hydroxide Storage

PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-SP-k

N/A N.2-02 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Tank (XTK0060), Sodium Hydroxide Storage

PB Carbon Steel Yard General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SP-ii See Note A-SP-j

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SP SP Spray Nozzles PB, SP Stainless Steel Ventilation * None Identified None Identified None Required TR00160-010, N/A N.2-01 N/A N/A The material/environment combination for this

Page 163: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 163 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Attachment IX component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-a See Note A-SP-b

V.A.1-a, V.A.1.1

T.2-15 No Yes V.A.1-a addresses Containment Spray System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SP SP Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SP-l

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-c See Note A-SP-d

VII.C2.2-a, VII.C2.2.1

N.2-05 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SP SP Tube & Tube Fittings PB Stainless Steel Yard None Identified None Identified None Required TR00160-010, V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation

Page 164: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 164 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Attachment XII components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SP-e See Note A-SP-f

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SP SP Valves (Body Only) PB Carbon Steel Yard General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SP-ii See Note A-SP-j

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SP SP Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-a See Note A-SP-b

V.A.4-a, V.A.4.1

T.2-15 No Yes V.A.4-a addresses Containment Spray System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 165: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 165 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

SP SP Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SP-l

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SP-c See Note A-SP-d

VII.C2.2-a, VII.C2.2.1

N.2-05 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0001, 2, 4, 5), Primary Side Sample Cooler - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SS-e See Note A-SS-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0001, 2, 4, 5), Primary Side Sample Cooler - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-c See Note A-SS-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as

Page 166: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 166 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0001, 2, 4, 5), Primary Side Sample Cooler - Tube

PB, HT Nickel-Based Alloy

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SS-j See Note A-SS-k

VII.E1.8-b, VII.E1.8.3

N.3-07 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in environment. Relative to material, the AMR results consider a nickel-based alloy, while the GALL item is stainless steel. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0001, 2, 4, 5), Primary Side Sample Cooler - Tube

PB, HT Nickel-Based Alloy

Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SS-l See Note A-SS-m

VII.E1.8-b, VII.E1.8.3

N.3-07 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in environment. Relative to material, the AMR results consider a nickel-based alloy, while the GALL item is stainless steel. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0022A/B), SS Auxiliary Sample Cooler - Tube

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-a See Note A-SS-b

V.D1.5-a, V.D1.5.2

N.3-06 No Partial V.D1.5-a addresses Emergency Core Cooling System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR

Page 167: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 167 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0022A/B), SS Auxiliary Sample Cooler - Tube

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-f See Note A-SS-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water system components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0003A/B/C), SG Blowdown Sample Cooler - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SS-e See Note A-SS-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0003A/B/C), SG Blowdown Sample Cooler - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-c See Note A-SS-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water system components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the

Page 168: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 168 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0003A/B/C), SG Blowdown Sample Cooler - Tube

PB Nickel-Based Alloy

Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-SS-l See Note A-SS-m

VII.E1.8-b, VII.E1.8.3

N.3-07 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in environment. Relative to material, the AMR results consider a nickel-based alloy, while the GALL item is stainless steel. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

SS SS Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SS-h See Note A-SS-o

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SS SS Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-c See Note A-SS-d

VIII.E.1-b, VIII.E.1.1

N.3-17 Yes, detection of aging effects is to be evaluated

Partial VIII.E.1-b addresses Condensate System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of

Page 169: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 169 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation and in meeting the intent of the pertinent GALL program.

SS SS Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-a See Note A-SS-b

V.D1.1-a, V.D1.1.2

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SS SS Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SS SS Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-SS-p

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

SS SS Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-f See Note A-SS-g

V.D1.5-a, V.D1.5.2

N.3-17 No Partial V.D1.5-a addresses Emergency Core Cooling System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of the

Page 170: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 170 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SS SS Pipe and Fittings PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-SS-q

VII.F2.4-a, VII.F2.4.1

N.3-01 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SS SS Pumps (Casing Only) (XPP0162A/B), SS System Flushing Water

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SS-e See Note A-SS-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SS SS Pumps (Casing Only) (XPP0162A/B), SS System Flushing Water

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-c See Note A-SS-d

VIII.E.1-b, VIII.E.1.1

N.3-17 Yes, detection of aging effects is to be evaluated.

Partial VIII.E.1-b addresses Condensate System piping. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effects, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SS SS Tank (XTK0147), Flushing Water Storage

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SS-p

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require

Page 171: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 171 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management during the period of extended operation as detailed in the applicable note.

SS SS Tank (XTK0147), Flushing Water Storage

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion, Corrosive Impacts of Alternate Wetting and Drying; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; Above Ground Tank Inspection

See Note A-SS-f See Note A-SS-g

V.D1.5-a, V.D1.5.2

N.3-20 No Partial V.D1.5-a addresses Emergency Core Cooling System components. VCSNS determined that the Chemistry Program and Above Ground Tank Inspection will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SS SS Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-a See Note A-SS-b

V.D1.1-a, V.D1.1.2

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SS SS Tube & Tube Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-SS-p

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended

Page 172: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 172 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

operation. SS SS Tube & Tube Fittings PB Stainless Steel Treated

Water Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-f See Note A-SS-g

V.D1.5-a, V.D1.5.2

N.3-17 No Yes V.D1.5-a addresses Emergency Core Cooling System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SS SS Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SS SS Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-a See Note A-SS-b

V.D1.4-b, V.D1.4.1

N.3-06 No Yes V.D1.4-b addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SS SS Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging

Page 173: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 173 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects were determined to require management during the period of extended operation as detailed in the applicable note.

SS SS Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SS-p

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SS SS Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-f See Note A-SS-g

V.D1.5-a, V.D1.5.2

N.3-17 No Partial V.D1.5-a addresses Emergency Core Cooling System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SS SS Valves (Body Only) PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-SS-q

VII.F2.4-a, VII.F2.4.1

N.3-01 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SW SW Couplings PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.1-a, VII.C3.1.1

T.3-17 No Partial VII.C3.1-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a

Page 174: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 174 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Couplings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-e

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Couplings PB Carbon Steel Underground Crevice Corrosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Buried Piping and Tanks Inspection

See Note A-SW-j

VII.H1.1-b, VII.H1.1.2

T.3-18 Yes, detection of aging effects and operating experience are to be further evaluated.

Partial VII.H1.1-b applies to underground Diesel Fuel Oil piping and fittings. The material, environment, aging effects requiring management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effects and credited activity. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Expansion Joints, Mechanical (XEJ0040A/B, 41A/B) - piping

PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.1-a, VII.C3.1.1

T.3-17 No Partial VII.C3.1-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 175: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 175 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program in effectively managing aging during the period of extended operation.

SW SW Expansion Joints, Mechanical (XEJ0040A/B, 41A/B) - piping

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-e

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Expansion Joints, Mechanical (XEJ0040A/B, 41A/B) - bellows

PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.2-a, VII.C3.2.1

T.3-17 No Partial VII.C3.2-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to stainless steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Expansion Joints, Mechanical (XEJ0040A/B, 41A/B) - bellows

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SW-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SW SW Motors (MPP0039/B/C), SW Pumps Air Motor Casings/Integral Bearing Cooler only

PB, HT Copper Oil None Identified None Identified None Required See Note A-SW-ii

VII.G.7-b, VII.G.7.2

T.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of

Page 176: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 176 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation as detailed in the applicable note.

SW SW Motors (MPP0039/B/C), SW Pumps Air Motor Casings/Integral Bearing Cooler only

PB, HT Copper Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-c, See Note A-SW-d

VII.C3.1-a, VII.C3.1.1

T.3-17, T.3-29

No Partial VII.C3.1-a addresses Ultimate Heat Sink components. VCSNS determined that the Service Water System Reliability and In-Service Testing Program will manage loss of material where the GALL item references "Open Cycle Cooling Water System" and "Selective Leaching of Materials." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Orifices PB, TH Stainless Steel Raw Water Crevice Corrosion, Erosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.2-a, VII.C3.2.1

T.3-17 No Partial VII.C3.2-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to stainless steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-SW-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SW SW Pipe and Fittings PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic

Loss of Material; Heat Exchanger

Service Water System Reliability

See Note A-SW-a, See

VII.C3.1-a, VII.C3.1.1

T.3-17 No Partial VII.C3.1-a addresses Ultimate Heat Sink components. VCSNS determined that the

Page 177: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 177 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Fouling and In-Service Testing Program

Note A-SW-b GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-g

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-e

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Pipe and Fittings PB Carbon Steel Underground Crevice Corrosion, Galvanic Corrosion, General Corrosion,

Loss of Material Buried Piping and Tanks Inspection

See Note A-SW-j

VII.H1.1-b, VII.H1.1.2

T.3-18 Yes, detection of aging effects and operating experience are to be

Partial VII.H1.1-b applies to underground Diesel Fuel Oil piping and fittings. The material, environment, aging effects requiring

Page 178: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 178 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Microbiologically Induced Corrosion (MIC), Pitting Corrosion

further evaluated. management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effects and credited activity. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Pipe and Fittings (Thermowells)

PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.2-a, VII.C3.2.1

T.3-17 No Partial VII.C3.2-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to stainless steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Pipe and Fittings (Thermowells)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SW-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SW SW Pipe and Fittings PB Carbon Steel Embedded None Identified None Identified None Required TR00160-010, Attachment VIII

N/A N.3-08 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SW SW Pumps (Casing Only) ( XPP0045A/B), SW Booster Pumps

PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.1-a, VII.C3.1.1

T.3-17 No Partial VII.C3.1-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component

Page 179: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 179 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Pumps (Casing Only) ( XPP0045A/B), SW Booster Pumps

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-e

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Pumps (Casing Only) (XPP0039AB/C), SW Pumps

PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.1-a, VII.C3.1.1

T.3-17 No Partial VII.C3.1-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Pumps (Casing Only) (XPP0039AB/C), SW Pumps

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-e

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring

Page 180: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 180 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Trash Racks (XRT0007A/B/C)

FI Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.1-a, VII.C3.1.1

T.3-17 No Partial VII.C3.1-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Traveling Screens (XRS0002A/B/C) - cloth screen

FI Stainless Steel Raw Water Crevice Corrosion, Erosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.2-a, VII.C3.2.1

T.3-17 No Partial VII.C3.2-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to stainless steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Traveling Screens FI Carbon Steel Raw Water Crevice Corrosion, Loss of Material; Service Water See Note A- VII.C3.1-a, T.3-17 No Partial VII.C3.1-a addresses Ultimate Heat Sink

Page 181: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 181 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(XRS0002A/B/C) - screen frame

Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Heat Exchanger Fouling

System Reliability and In-Service Testing Program

SW-a, See Note A-SW-b

VII.C3.1.1 components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Tube & Tube Fittings PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.2-a, VII.C3.2.1

T.3-17 No Partial VII.C3.2-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to stainless steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SW SW Tube & Tube Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-SW-f

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to

Page 182: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 182 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

SW SW Valves (Body Only) PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.2-a, VII.C3.2.1

T.3-17 No Partial VII.C3.2-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to carbon steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-g

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SW-e

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during

Page 183: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 183 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Valves (Body Only) PB Stainless Steel Raw Water Crevice Corrosion, Erosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Biological Materials, Particulates

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-SW-a, See Note A-SW-b

VII.C3.2-a, VII.C3.2.1

T.3-17 No Partial VII.C3.2-a addresses Ultimate Heat Sink components. VCSNS determined that the GALL item referenced activity "Selective Leaching of Materials" is not applicable to stainless steel for this component/component type. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SW SW Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SW SW Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SW-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Demineralizers (XDM0007A/B/C/D)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effects/mechanisms requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program (XI.M2) attributes. Refer to TR00160-020 for

Page 184: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 184 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

TR TR Demineralizers (XDM0007A/B/C/D)

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Heat Exchanger (XHE0001), Moderating - Channel Head

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a, V.D1.6.1

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0001), Moderating - Channel Head

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Heat Exchanger (XHE0001), Moderating - Shell

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a, V.D1.6.3

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable

Page 185: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 185 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0001), Moderating - Shell

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Heat Exchanger (XHE0001), Moderating - Tubes

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a, V.D1.6.2

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

Page 186: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 186 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

TR TR Heat Exchanger (XHE0001), Moderating - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0008), Letdown Chiller - Channel Head

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a, V.D1.6.1

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0008), Letdown Chiller - Channel Head

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the

Page 187: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 187 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Heat Exchanger (XHE0008), Letdown Chiller - Tubes

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a, V.D1.6.2

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0008), Letdown Chiller - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-TR-c, See Note A-TR-d

VII.C2.2-a T.3-15 No Partial VII.C2.2-a addresses Closed Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will manage loss of material for stainless steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item which has the same material, environment and aging effects. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0008), Letdown Chiller - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the

Page 188: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 188 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC) intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0008), Letdown Chiller - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-TR-c, See Note A-TR-d

VII.C2.2-a T.3-15 No Partial VII.C2.2-a addresses Closed Cycle Cooling Water System components. VCSNS determined that the Chemistry Program will manage loss of material for stainless steel heat exchanger components, where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects. However, the attributes of this program/activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0015), Letdown Reheat - Shell

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a, V.D1.6.3

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent

Page 189: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 189 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0015), Letdown Reheat - Shell

PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Heat Exchanger (XHE0015), Letdown Reheat - Tubes

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a, V.D1.6.2

N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0015), Letdown Reheat - Tubes

PB Stainless Steel Ventilation * None Identified None Identified None Required TR00160-010, Attachment VII

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require

Page 190: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 190 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management during the period of extended operation as detailed in the applicable note.

TR TR Heat Exchanger (XHE0015), Letdown Reheat - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.6-a N.3-06 No Partial V.D1.6-a addresses Emergency Core Cooling System heat exchangers. VCSNS determined that the Chemistry Program, which meets the intent of GALL program XI.M2, will manage loss of material for stainless steel heat exchanger components where the applicable GALL program is "Closed Cycle Cooling Water System." The material, environment and aging effects requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effects, except that the GALL item does not address stress corrosion cracking to which the heat exchanger is considered susceptible. Furthermore, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

TR TR Heat Exchanger (XHE0015), Letdown Reheat - Tubesheet(s)

PB Stainless Steel Ventilation * None Identified None Identified None Required TR00160-010, Attachment VII

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Orifices (IFE00385) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent

Page 191: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 191 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the pertinent GALL program. TR TR Orifices (IFE00385) PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010,

Attachment X.V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation

components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

TR TR Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-TR-e

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, except that VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for piping external surfaces. The identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

TR TR Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not

Page 192: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 192 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

TR TR Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

TR TR Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-TR-a, See Note A-TR-b

V.D1.4-b, V.D1.4.1

N.3-06 No Yes V.D1.4-b addresses Emergency Core Cooling System components. The material, environment and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment and credited program. VCSNS determined that cracking due to stress corrosion cracking (SCC) is not an aging effect requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

TR TR Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required TR00160-010, Attachment X.

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VL VL Air Handling Units (XAH-01A/B-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the

Page 193: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 193 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Units (XAH-01A/B-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Unit (XAH-02-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Unit (XAH-02-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in

Page 194: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 194 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-04A/B-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Units (XAH-04A/B-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Unit (XAH-06-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes

Page 195: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 195 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Unit (XAH-06-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Unit (XAH-08-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Unit (XAH-08-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring

Page 196: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 196 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-09A/B-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Units (XAH-09A/B-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-11A/B-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program

Page 197: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 197 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Units (XAH-11A/B-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-19A/B-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Units (XAH-19A/B-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL

Page 198: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 198 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-32-VL, XAH-33-VL)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Air Handling Units (XAH-32-VL, XAH-33-VL)

PB Galvanized Steel

Ventilation Galvanic Corrosion Loss of Material Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.1-a, VII.F1.1.2

T.3-05 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice, general MIC, and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Cooling Coils - Fins HT Copper Ventilation Galvanic Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Preventive Maintenance Activities - Ventilation Systems Inspections

See Note A-VL-b See Note A-VL-c

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of addtional aging effects requiring management that are not addressed in GALL for this item. However, the identified

Page 199: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 199 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Cooling Coils - Headers PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Cooling Coils - Headers PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-VL-d See Note A-VL-e

VII.F1.3-a, VII.F1.3.1

T.3-15 No Partial VII.F1.3-a addresses Control Room Area Ventilation System piping and fittings. VCSNS determined that the Chemistry Program will manage the applicable aging effects where the GALL item references "Closed Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited programs. Additionally, the attributes of this program/activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

VL VL Cooling Coils - Tubes PB, HT Copper Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Chemistry Program, Heat Exchanger Inspections

See Note A-VL-d See Note A-VL-e

N/A N.3-28 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

VL VL Cooling Coils - Tubes PB, HT Copper Ventilation Galvanic Corrosion; Loss of Material; Preventive See Note A- VII.F1.2-a, T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area

Page 200: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 200 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Particulates Heat Exchanger Fouling

Maintenance Activities - Ventilation Systems Inspections

VL-b See Note A-VL-c

VII.F1.2.1 Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Ductwork (including fire damper housings)

PB Galvanized Steel

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VL-a See Note A-VL-f

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VL VL Ductwork (including fire damper housings)

PB Galvanized Steel

Ventilation None Identified None Identified None Required See Note A-VL-b See Note A-VL-c

VII.F1.1-a N.3-03 Yes, plant specific No VII.F1.1-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VL VL Tube & Tube Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-VL-a See Note A-VL-f

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the

Page 201: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 201 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VL VL Tube & Tube Fittings PB Stainless Steel Ventilation None Identified None Identified None Required See Note A-VL-c

VII.F1.4-a N.3-02 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Pumps (Casing Only) (XPP0048A/B/C), Chilled Water

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VU VU Pumps (Casing Only) (XPP0048A/B/C), Chilled Water

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-VU-b See Note A-VU-c

VII.C2.3-a, VII.C2.3.1

T.3-15 No Partial VII.C2.3-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Fins

HT Copper Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-ii

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the

Page 202: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 202 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

applicable note. VU VU Condensers

(XHX0001A/B/C-CN1), Chilled Water Unit - Shells

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Shells

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Tubes

PB, HT Copper Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-ii

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Tubes

PB, HT Copper Raw Water Crevice Corrosion, Erosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Particulates, Biological Materials

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-VU-u See Note A-VU-v

VII.C1.3-a, VII.C1.3.5

T.3-17 No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Tubesheets

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Condensers PB Carbon Steel Raw Water Crevice Corrosion, Loss of Material; Service Water See Note A- VII.C1.3-a, T.3-17 No Partial VII.C1.3-a addresses Open-Cycle Cooling

Page 203: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 203 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(XHX0001A/B/C-CN1), Chilled Water Unit - Tubesheets

Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Particulates, Biological Materials

Heat Exchanger Fouling

System Reliability and In-Service Testing Program

VU-s See Note A-VU-t

VII.C1.3.4 Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Water boxes

PB Carbon Steel Raw Water Crevice Corrosion, Erosion, Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion; Particulates, Biological Materials

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-VU-s See Note A-VU-t

VII.C1.3-a, VII.C1.3.3

T.3-17 No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Water boxes

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Fins

HT Copper Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-ii

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Evaporators (XHX0001A/B/C-EV1),

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed

Page 204: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 204 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Chilled Water Unit - Shells

for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Shells

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Tubes

PB, HT Copper Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-ii

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Tubes

PB, HT Copper Treated Water

Crevice Corrosion, Erosion-Corrosion, Pitting Corrosion

Loss of Material Chemistry Program, Heat Exchanger Inspections

See Note A-VU-n See Note A-VU-o

N/A N.3-28 N/A N/A Component/component type has a unique material and environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program/activity in effectively managing aging during the period of extended operation.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Tubesheets

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Tubesheets

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-VU-b See Note A-VU-c

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component

Page 205: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 205 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Water boxes

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Water boxes

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-VU-b See Note A-VU-c

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect/mechanisms. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Compressors (XHX0001A/B/C-GC1), Chilled Water Unit - Housing Only

PB Cast Iron Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-k

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Compressors PB Cast Iron Sheltered Galvanic Corrosion, Loss of Material Inspections for See Note A- VII.I.1-b, T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of

Page 206: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 206 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(XHX0001A/B/C-GC1), Chilled Water Unit - Housing Only

General Corrosion, Pitting Corrosion

Mechanical Components

VU-j VII.I.1.1 carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging effects as carbon steel, if both materials were exposed to a sheltered environment. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VU VU Flow Control Chambers (XHX0001A/B/C-PS1), Chilled Water Unit

PB, TH Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Flow Control Chambers (XHX0001A/B/C-PS1), Chilled Water Unit

PB, TH Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VU VU Pumps (XPP0186A/B/C), Chilled Water Cleanup System Fluid Ejector

PB, GR Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Pumps (XPP0186A/B/C), Chilled Water Cleanup System Fluid Ejector

PB, GR Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed

Page 207: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 207 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VU VU Pumps (XPP0186A/B/C), Chilled Water Cleanup System Fluid Ejector

PB, GR Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-g

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Pumps (XPP0186A/B/C), Chilled Water Cleanup System Fluid Ejector

PB, GR Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Sight Glasses (IMG09166A/B/C), Chilled Water Unit Cleanup System

PB Glass Air-Gas None Identified None Identified None Required See Note A-VU-w

N/A N.3-23 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Sight Glasses (IMG09166A/B/C), Chilled Water Unit Cleanup System

PB Glass Sheltered None Identified None Identified None Required See Note A-VU-x

N/A N.3-23 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Tube & Tube Fittings, Chilled Water Cleanup System

PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-g

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Eductor, Chilled Water Lubrication System

PB, GR Carbon Steel Oil None Identified None Identified None Required See Note A-VU-p

VII.G.7-a N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 208: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 208 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VU VU Eductor, Chilled Water Lubrication System

PB, GR Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

VU VU Eductor, Chilled Water Lubrication System

PB, GR Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Filters - Chilled Water Lubrication System

PB, FI Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Pumps (Casing Only) (XHX0001A/B/C-PP1, 2, 3, 4) - Chilled Water Unit Lubrication System

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Pumps (Casing Only) (XHX0001A/B/C-PP1, 2, 3, 4) - Chilled Water Unit Lubrication System

PB Cast Iron Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-j

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging effects as carbon steel, if both materials were exposed to a sheltered environment. The component/component type AMR results are consistent with the identified GALL item in

Page 209: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 209 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Pipe and Fittings, Chilled Water Lubrication System

PB Carbon Steel Oil None Identified None Identified None Required See Note A-VU-p

VII.G.7-a N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Pipe and Fittings, Chilled Water Lubrication System

PB Stainless Steel Oil None Identified None Identified None Required See Note A-VU-q

VIII.G.5-d N.3-05 Yes, plant specific No GALL Item No. VIII.G.5-d addresses bearing oil coolers. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Tube & Tube Fittings, Chilled Water Lubrication System

PB Stainless Steel Oil None Identified None Identified None Required See Note A-VU-q

VIII.G.5-d N.3-05 Yes, plant specific No GALL Item No. VIII.G.5-d addresses bearing oil coolers. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Valves (Body Only), Chilled Water Lubrication System

PB Carbon Steel Oil None Identified None Identified None Required See Note A-VU-p

VII.G.7-a N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Valves (Body Only), Chilled Water Lubrication System

PB Stainless Steel Oil None Identified None Identified None Required See Note A-VU-q

VIII.G.5-d N.3-05 Yes, plant specific No GALL Item No. VIII.G.5-d addresses bearing oil coolers. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 210: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 210 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VU VU Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Orifices PB, TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-VU-d See Note A-VU-e

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Pipe and Fittings PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-VU-b See Note A-VU-c

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes

Page 211: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 211 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-VU-d See Note A-VU-e

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Filters - Chilled Water Purge System

PB, FI Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-g

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Filters - Chilled Water Purge System

PB, FI Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Pipe and Fittings, Chilled Water Purge System

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the

Page 212: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 212 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

applicable note. VU VU Pipe and Fittings, Chilled

Water Purge System PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-

VU-g N/A N.3-04 N/A N/A The material/environment combination for this

component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Purge Units (XHX0001A/B/C-GS1) - Chilled Water Purge System

PB, GR Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Purge Units (XHX0001A/B/C-GS1) - Chilled Water Purge System

PB, GR Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Purge Units (XHX0001A/B/C-GS1) - Chilled Water Purge System

PB, GR Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-g

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Purge Units (XHX0001A/B/C-GS1) - Chilled Water Purge System

PB, GR Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Valves (Body Only), Chilled Water Purge System

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-h

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 213: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 213 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VU VU Valves (Body Only), Chilled Water Purge System

PB Stainless Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-VU-g

N/A N.3-04 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Tanks (XTK0174A/B), Chilled Water Expansion

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Corrosive Impacts of Alternate Wetting and Drying; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; Above Ground Tank Inspection

See Note A-VU-b See Note A-VU-c

VII.C2.4-a, VII.C2.4.1

N.3-19 No No VII.C2.4-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program for managing aging. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of this program/activity are not fully consistent with the corresponding program (XI.M21) attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation. In addition, the Above Ground Tank Inspection will detect and characterize the affects of aging, if any. This one-time inspection, as described in TR00160-020, is focused on the air-water interface inside of certain tanks (and the corrosive impacts of alternate wetting and drying) and is not to be confused with GALL Program XI.M29, "Above Ground Carbon Steel Tanks", which is focused on inaccessible areas of the external surface of certain tanks.

VU VU Tanks (XTK0174A/B), Chilled Water Expansion

PB Carbon Steel Yard General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VU-l See Note A-VU-m

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A- V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation

Page 214: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 214 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VU-f components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Tube & Tube Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-VU-d See Note A-VU-e

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of the credited program meet the intent of another GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Valves (Body Only) PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VU-a

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-VU-b See Note A-VU-c

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the

Page 215: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 215 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

VU VU Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-VU-f

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-VU-d See Note A-VU-e

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-a See Note A-WG-b

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WG-c See Note A-

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring

Page 216: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 216 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

WG-d management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-a See Note A-WG-b

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL items are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Spiral Baffle

TH Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-e See Note A-WG-f

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Tube Coils

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-e See Note A-

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are

Page 217: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 217 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

WG-f consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Tube Manifolds

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-e See Note A-WG-f

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WG-c See Note A-WG-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Channel Head

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WG-c See Note A-WG-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent

Page 218: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 218 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Channel Head

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-a See Note A-WG-b

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-e See Note A-WG-f

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Tubesheet

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-e See Note A-WG-f

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects.

Page 219: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 219 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG CC Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WG-c See Note A-WG-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WG CC Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-a See Note A-WG-b

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Pipe and Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-WG-g

V.C.1-b, V.C.1.2

N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging

Page 220: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 220 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects were determined to require management during the period of extended operation as detailed in the applicable note.

WG WG Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Waste Gas System Inspection

See Note A-WG-e See Note A-WG-f

VII.C2.2-a, VII.C2.2.1

N.3-15 No No VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Waste Gas System Inspection. Certain aging effects not addressed by the GALL item are also managed by the credited program. Component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WG WG Tube & Tube Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WG-c See Note A-WG-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WG WG Tube & Tube Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-a See Note A-WG-b

VII.C2.1-a, VII.C2.1.1

T.3-15 No Partial VII.C2.1-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes

Page 221: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 221 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WG-c See Note A-WG-d

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WG WG Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WG-a See Note A-WG-b

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WG WG Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-WG-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

WG WG Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Waste Gas System Inspection

See Note A-WG-e See Note A-

VII.C2.2-a, VII.C2.2.1

N.3-15 No No VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are

Page 222: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 222 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC) WG-f consistent with the identified GALL item in material, environment and aging effects. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Waste Gas System Inspection. Certain aging effects not addressed by the GALL item are also managed by the credited program. Component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Condensers (XEV0029-CN1, XEV0029-CN2), WasteEvaporator - Channel Head

PB Carbon Steel/Stainless Steel Combination

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-e See Note A-WL-n See Note A-WL-m

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WL WL Condensers (XEV0029-CN1, XEV0029-CN2), WasteEvaporator - Channel Head

PB Carbon Steel/Stainless Steel Combination

Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-c See Note A-WL-d See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

Page 223: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 223 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

WL WL Condensers (XEV0029-CN1, XEV0029-CN2), WasteEvaporator - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Condensers (XEV0029-CN1, XEV0029-CN2), WasteEvaporator - Tubesheet

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XEV0029-HE2), Waste Evaporator - Shell

PB Carbon Steel/Stainless Steel Combination

Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-e See Note A-WL-n See Note A-WL-m

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 224: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 224 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. WL WL Heat Exchanger

(XEV0029-HE2), Waste Evaporator - Shell

PB Carbon Steel/Stainless Steel Combination

Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-c See Note A-WL-d See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XEV0029-HE2), Waste Evaporator - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XEV0029-HE2), Waste Evaporator - Tubesheet

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes

Page 225: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 225 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0012), RC Drain Tank - Shell

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-h See Note A-WL-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WL WL Heat Exchanger (XHE0012), RC Drain Tank - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WL-c See Note A-WL-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0012), RC Drain Tank - Tubes

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Liquid Waste System Inspection

See Note A-WL-a See Note A-WL-b

V.D1.1-a, V.D1.1.5

N.3-21 No No V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Additional VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion, which are also managed with the Liquid Waste System Inspection. This component/component type is managed by

Page 226: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 226 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0012), RC Drain Tank - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0012), RC Drain Tank - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Liquid Waste System Inspection

See Note A-WL-a See Note A-WL-b

V.D1.1-a, V.D1.1.5

N.3-21 No No V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Additional VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion, which are also managed with the Liquid Waste System Inspection. This component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0012), RC Drain Tank - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry

Page 227: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 227 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0022), Waste Evap. Concentrates Sample - Manifolds

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Liquid Waste System Inspection

See Note A-WL-a See Note A-WL-b

V.D1.1-a, V.D1.1.5

N.3-21 No No V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Additional VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion, which are also managed with the Liquid Waste System Inspection. This component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0022), Waste Evap. Concentrates Sample - Manifolds

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0022), Waste Evap. Concentrates Sample - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-e See Note A-WL-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and

Page 228: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 228 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WL WL Heat Exchanger (XHE0022), Waste Evap. Concentrates Sample - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-WL-c See Note A-WL-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0022), Waste Evap. Concentrates Sample - Tubes

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Liquid Waste System Inspection

See Note A-WL-a See Note A-WL-b

V.D1.1-a, V.D1.1.5

N.3-21 No No V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Additional VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion, which are also managed with the Liquid Waste System Inspection. This component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0022), Waste Evap. Concentrates Sample - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-WL-f See Note A-WL-g

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the

Page 229: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 229 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Pipe and Fittings PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-WL-j

VII.H2.3-a, VII.H2.3.1

T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

WL WL Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-h See Note A-WL-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WL WL Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-e See Note A-WL-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 230: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 230 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. WL WL Pipe and Fittings PB Stainless Steel Borated

Water Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Liquid Waste System Inspection

See Note A-WL-a See Note A-WL-b

V.D1.1-a, V.D1.1.5

N.3-21 No No V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Additional VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion, which are also managed with the Liquid Waste System Inspection. This component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

WL WL Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-WL-m

V.C.1-b, V.C.1.2

N.3-09 Yes, plant specific No V.C.1-b addresses containment isolation components. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Valves (Body Only) PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-WL-k

VII.F2.4-a, VII.F2.4.1

N.3-01 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

WL WL Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-h See Note A-WL-l

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program

Page 231: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 231 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WL WL Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-WL-e See Note A-WL-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

WL WL Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Liquid Waste System Inspection

See Note A-WL-a See Note A-WL-b

V.D1.1-a, V.D1.1.5

N.3-21 No No V.D1.1-a addresses Emergency Core Cooling System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. Additional VCSNS AMR aging effects requiring management are loss of material due to crevice and pitting corrosion, which are also managed with the Liquid Waste System Inspection. This component/component type is managed by an activity that is not evaluated in GALL Chapter XI, and is therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

WL WL Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

WL WL Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-WL-m

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging

Page 232: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 232 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects were determined to require management during the period of extended operation as detailed in the applicable note.

ND ND Pipe and Fittings PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-ND-c. Also see TR00160-010, Attachment # VII

VII.F2.4-a, VII.F2.4.1

N.3-01 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

WL WL Valves (Body Only) PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-WL-j

VII.H2.3-a, VII.H2.3.1

T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CO CO Tank (XTK0008), Condensate Storage

PB Carbon Steel Ventilation * Galvanic Corrosion, General Corrosion

Loss of Material Above Ground Tank Inspection

See Note A-CO-g, See Note A-CO-h

VIII.E.5-a, VIII.E.5.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.E.5-a addresses the Condensate Storage Tank internal surfaces. The material and aging effects requiring management for this component/component type are consistent with the identified GALL item which has the same material and aging effects. Relative to the environment, the identified GALL item references treated water, while the component/component type AMR results consider the moist air space above the treated water line in the CST. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection, which includes measures to verify the effectiveness of water chemistry control. The Above Ground Tank Inspection is a one-time inspection activity that will detect and characterize the loss of material due to general and galvanic corrosion as a result of the corrosive impacts of alternate wetting and drying, primarily at the air-water interface, and not to verify the effectiveness of chemistry control. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in detecting and characterizing the affects of aging during the period of extended operation.

DG DG Tanks (XTK0020A/B), PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A- VII.H2.3-a, T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel

Page 233: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 233 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Fuel Oil Day DG-a See Note A-DG-n

VII.H2.3.1 Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Tanks (XTK0053A/B), Fuel Oil Storage

PB Carbon Steel Air-Gas None Identified None Identified None Required See Note A-DG-a See Note A-DG-n

VII.H2.3-a, VII.H2.3.1

T.3-05 Yes, plant specific No VII.H2.3-a addresses Emergency Diesel Generator System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

DG DG Pipe and Fittings PB Carbon Steel Raw Water Erosion, Galvanic Corrosion, General Corrosion, Crevice Corrosion, Pitting Corrosion, Microbiologically Induced Corrosion (MIC); Particulates, Biological Materials

Loss of Material; Heat Exchanger Fouling

Service Water System Reliability and In-Service Testing Program

See Note A-DG-zq See Note A-DG-zr

VII.C1.3-a, VII.C1.3.3

T.3-17 No Partial VII.C1.3-a addresses Open-Cycle Cooling Water System components. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Selective leaching is not an applicable aging effect for this component and so the GALL-referenced Selective Leaching AMP is not applicable. However, the attributes of this activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CC CC Valves (Body Only) PB Carbon Steel Ventilation * General Corrosion Loss of Material Above Ground Tank Inspection

See Note A-CC-o See Note A-CC-p

VII.F1.4-a, VII.F1.4.1

N.3-19 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that pitting and crevice corrosion were not applicable aging effects for this component, as discussed in the referenced notes. The Above Ground Tank Inspection will detect and characterize the affects of aging, if any in certain tanks and interconnected piping and valves. This one-time inspection, as described in TR00160-020, is focused on the air-water interface inside of certain tanks and is not to be confused with GALL Program XI.M29, "Above

Page 234: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 234 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Ground Carbon Steel Tanks", which is focused on inaccessible areas of the external surface of certain tanks. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively detecting and characterizing the effects of aging during the period of extended operation.

CC CC Tank (XTK0003), CC Surge Tank

PB Carbon Steel Ventilation * Galvanic Corrosion, General Corrosion

Loss of Material Above Ground Tank Inspection

See Note A-CC-o See Note A-CC-p

VII.F1.4-a, VII.F1.4.1

N.3-19 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that pitting and crevice corrosion were not applicable aging effects for this component, as discussed in the referenced notes. The Above Ground Tank Inspection will detect and characterize the affects of aging, if any due to galvanic or general corrosion in the air space (wetted ambient) of the Tank. This one-time inspection, as described in TR00160-020, is focused on the air-water interface inside of certain tanks and is not to be confused with GALL Program XI.M29, "Above Ground Carbon Steel Tanks", which is focused on inaccessible areas of the external surface of certain tanks. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively detecting and characterizing the effects of aging during the period of extended operation.

CC CC Pipe and Fittings PB Carbon Steel Ventilation * General Corrosion Loss of Material Above Ground Tank Inspection

See Note A-CC-o See Note A-CC-p

VII.F1.4-a, VII.F1.4.1

N.3-19 Yes, plant specific No VII.F1.4-a addresses Control Room Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that pitting and crevice corrosion were not applicable aging effects for this component, as discussed in the referenced notes. The Above Ground Tank Inspection will detect and characterize the affects of aging, if any in both the tank itself and connected piping and fittings. This one-time inspection, as described in TR00160-020, is focused on the air-water interface inside of certain tanks and is not to be confused with GALL Program XI.M29, "Above Ground Carbon Steel Tanks", which is focused on

Page 235: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 235 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

inaccessible areas of the external surface of certain tanks. Also, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively detecting and characterizing the effects of aging during the period of extended operation.

VU VU Tanks (XTK0174A/B), Chilled Water Expansion

PB Carbon Steel Ventilation * General Corrosion Loss of Material Above Ground Tank Inspection

See Note A-VU-y See Note A-VU-z

VII.H2.2-a N.3-19 Yes, plant specific No GALL Item No. VII.H2.2-a addresses the diesel engine starting air subsystem. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect/mechanism. VCSNS determined that pitting and crevice corrosion were not applicable aging effects for this component, as discussed in the referenced notes. The Above Ground Tank Inspection will detect and characterize the affects of aging, if any. This one-time inspection, as described in TR00160-020, is focused on the air-water interface inside of certain tanks and is not to be confused with GALL Program XI.M29, "Above Ground Carbon Steel Tanks", which is focused on inaccessible areas of the external surface of certain tanks. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively detecting and characterizing the effects of aging during the period of extended operation.

BR BR Condensers (XEV0008-CN1, XEV0008-CN2), Recycle Evaporator - Channel Head

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

Page 236: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 236 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

BR BR Heat Exchanger (XEV0008-HE2), Recycle Evaporator - Shell

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-BR-c, See Note A-BR-d

VII.C2.2-a, VII.C2.2.1

T.3-15 No Partial VII.C2.2-a addresses Closed-Cycle Cooling Water System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Relative to the aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program, while the component/component type AMR results credit the Chemistry Program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

SS SS Pumps (Casing Only) (XPP0162A/B), SS System Flushing Water

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-SS-p

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SS SS Pumps (Casing Only) (XPP0162A/B), SS System Flushing Water

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-SS-f See Note A-SS-g

V.D1.5-a, V.D1.5.2

N.3-17 No Partial V.D1.5-a addresses Emergency Core Cooling System components. VCSNS determined that the Chemistry Program will adequately manage the applicable aging effects instead of the GALL Closed-Cycle Cooling Water System AMP. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RH RH Heat Exchangers (XHE0005A/B), RHR - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RH-e See Note A-RH-h

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the

Page 237: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 237 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RH RH Heat Exchangers (XPP0031A/B-HE1), RH Pump Seal - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RH-e See Note A-RH-h

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BR BR Heat Exchanger (XHE0021), Recycle Evap. Concentrates Sample - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-BR-a, See Note A-BR-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited activity. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Condensers (XEV0029-CN1, XEV0029-CN2), WasteEvaporator - Channel Head

PB Carbon Steel/Stainless Steel Combination

Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WL-e See Note A-WL-n See Note A-WL-m

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XEV0029-HE2), Waste Evaporator - Shell

PB Carbon Steel/Stainless Steel Combination

Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WL-e See Note A-WL-n See Note A-WL-m

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the

Page 238: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 238 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0012), RC Drain Tank - Shell

PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WL-h See Note A-WL-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Heat Exchanger (XHE0022), Waste Evap. Concentrates Sample - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WL-e See Note A-WL-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WL-h See Note A-WL-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-WL-e See Note A-WL-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, an additional VCSNS AMR aging effect requiring management is loss of material due to microbiologically induced corrosion (MIC), which is also managed with the referenced activity. The identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

Page 239: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 239 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

WL WL Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WL-h See Note A-WL-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WL WL Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WL-e See Note A-WL-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SS SS Heat Exchangers (XCE0001, 2, 4, 5), Primary Side Sample Cooler - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SS-e See Note A-SS-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SS SS Heat Exchangers (XCE0003A/B/C), SG Blowdown Sample Cooler - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SS-e See Note A-SS-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in

Page 240: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 240 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

meeting the intent of the pertinent GALL program.

SS SS Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SS-h See Note A-SS-o

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SS SS Pumps (Casing Only) (XPP0162A/B), SS System Flushing Water

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SS-e See Note A-SS-n

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SF SF Heat Exchangers (XHE0007A/B), SFC - Channel Head

PB Carbon Steel/Stainless Steel Combination

Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SF-d, See Note A-SF-e

V.E.1-b, V.E.1.1

T.3-05 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. However, the identified GALL recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SF SF Heat Exchangers (XHE0007A/B), SFC - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SF-d, See Note A-SF-e

V.E.1-b, V.E.1.1

T.3-05 Yes, plant specific No V.E.1-b addresses carbon steel external surfaces. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects. However, the identified GALL recommends plant specific evaluation of the credited program. Refer to TR00160-020 for

Page 241: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 241 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SI SI Tanks (XTK0028A/B/C), SI Accumulator

PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SI-e See Note A-SI-f

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SI SI Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SI-e See Note A-SI-f

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SP SP Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SP-e See Note A-SP-f

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SP SP Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SP-e See Note A-SP-f

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Tube Coils

PB Stainless Steel Air-Gas Stress Corrosion Cracking (SCC)

Cracking Waste Gas System Inspection

See Note A-WG-j

VII.F2.4-a, VII.F2.4.1

N.3-15 Yes, plant specific No VII.F2.4-a and VII.F2.4.1 address ventilation system filters, and housing and supports, respectively. An aging effect not addressed by the GALL items are managed by the credited program. Component/component

Page 242: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 242 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

type is managed by a program that is not evaluated in GALL Chapter XI and is, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Tube Manifolds

PB Stainless Steel Air-Gas Stress Corrosion Cracking (SCC)

Cracking Waste Gas System Inspection

See Note A-WG-j

VII.F2.4-a, VII.F2.4.1

N.3-15 Yes, plant specific No VII.F2.4-a and VII.F2.4.1 address ventilation system filters, and housing and supports, respectively. An aging effect not addressed by the GALL items are also managed by the credited program. Component/component type is managed by a program that is not evaluated in GALL Chapter XI and is, therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

WG WG Pipe and Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-WG-h

VII.F2.4-a, VII.F2.4.1

T.3-05 Yes, plant specific No VII.F2.4-a and VII.F2.4.1 address ventilation system filters, and housing and supports, respectively. The component/component type AMR results are consistent with the identified GALL items in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

WG WG Valves (Body Only) PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-WG-h

VII.F2.4-a, VII.F2.4.1

T.3-05 Yes, plant specific No VII.F2.4-a and VII.F2.4.1 address ventilation system filters, and housing and supports, respectively. The component/component type AMR results are consistent with the identified GALL items in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Agitator and Mixer (XAJ0015), Boric Acid Blender

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effects/mechanisms requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 243: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 243 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Agitator and Mixer (XAJ0015), Boric Acid Blender

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Demineralizers (XDM0005A/B), Mixed Bed

PB, FI Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effects/mechanisms requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Demineralizers (XDM0005A/B), Mixed Bed

PB, FI Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Demineralizer (XDM0008), Cation Bed

PB, FI Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effects/mechanisms requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program

Page 244: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 244 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Demineralizer (XDM0008), Cation Bed

PB, FI Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Filters PB, FI Carbon Steel Lube Oil None Identified None Identified None Required See Note A-CS-h

VII.G.7-b N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Filters PB, FI Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Filters PB, FI Cast Iron Lube Oil None Identified None Identified None Required See Note A-CS-q

N/A N.3-05 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Filters PB, FI Cast Iron Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-o, See Note A-CS-p

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging effects as carbon steel, if both materials were exposed to a sheltered environment. The

Page 245: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 245 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Filters PB, FI Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

T.2-15, N.3-06

No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Filters PB, FI Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Flexible Coupling PB Copper Lube Oil None Identified None Identified None Required See Note A-CS-r

N/A N.3-05 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Flexible Coupling PB Copper Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-s, See Note A-CS-t

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. VCSNS uses the same AMP (BAC Surveillances) for the external surfaces of carbon steel and copper. Therefore, the material, environment, aging

Page 246: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 246 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Gearboxes (XPP0043A/B/C-GB), Charging/SI Pumps

PB Carbon Steel Lube Oil None Identified None Identified None Required See Note A-CS-h

VII.G.7-b N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Gearboxes (XPP0043A/B/C-GB), Charging/SI Pumps

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Heat Exchanger (XHE0003), Regenerative - Channel Head

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.7-c, VII.E1.7.1

T.3-09 Yes, plant specific No VII.E1.7-c addresses Regenerative Heat Exchanger components. The component/component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

Page 247: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 247 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

CS CS Heat Exchanger (XHE0003), Regenerative - Channel Head

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchanger (XHE0003), Regenerative - Shell

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.7-c, VII.E1.7.4

T.3-09 Yes, plant specific No VII.E1.7-c addresses Regenerative Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0003), Regenerative - Shell

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchanger (XHE0003), Regenerative - Tubes

PB, HT Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.7-c, VII.E1.7.3

T.3-09 Yes, plant specific No VII.E1.7-c addresses Regenerative Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0003), Regenerative - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.7-c, VII.E1.7.2

T.3-09 Yes, plant specific No VII.E1.7-c addresses Regenerative Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the

Page 248: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 248 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Channel Head

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.1

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Channel Head

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Shell

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-k, See Note A-CS-l

VII.E1.8-d, VII.E1.8.5

T.3-14 No Yes VII.E1.8-d addresses Letdown Heat Exchanger components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CS-m, See Note A-CS-n

VII.E1.8-c, VII.E1.8.4

T.3-15 No Partial VII.E1.8-c addresses Letdown Heat Exchanger components. VCSNS determined that the Chemistry Program will manage the applicable aging effects, where the GALL item references "Closed Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item,

Page 249: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 249 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. Additionally, the attributes of this program/activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Tubes

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.3

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.3

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging

Page 250: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 250 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

during the period of extended operation. CS CS Heat Exchanger

(XHE0009), Excess Letdown - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0011), Seal Water - Channel Head

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.1

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0011), Seal Water - Channel Head

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchanger (XHE0011), Seal Water - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

VII.E1.8-d, VII.E1.8.5

T.3-14 No Yes VII.E1.8-d addresses Letdown Heat Exchanger components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 251: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 251 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. CS CS Heat Exchanger

(XHE0011), Seal Water - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CS-m, See Note A-CS-n

VII.E1.8-c, VII.E1.8.4

T.3-15 No Partial VII.E1.8-c addresses Letdown Heat Exchanger components. VCSNS determined that the Chemistry Program will manage the applicable aging effects, where the GALL item references "Closed Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. Additionally, the attributes of this program/activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0011), Seal Water - Tubes

PB, HT Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.3

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0011), Seal Water - Tubes

PB, HT Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.3

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0011), Seal Water - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and

Page 252: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 252 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0011), Seal Water - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0014), Letdown - Channel Head

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.1

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0014), Letdown - Channel Head

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchanger (XHE0014), Letdown - Shell

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

VII.E1.8-d, VII.E1.8.5

T.3-14 No Yes VII.E1.8-d addresses Letdown Heat Exchanger components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the

Page 253: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 253 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Heat Exchanger (XHE0014), Letdown - Shell

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-CS-m, See Note A-CS-n

VII.E1.8-c, VII.E1.8.4

T.3-15 No Partial VII.E1.8-c addresses Letdown Heat Exchanger components. VCSNS determined that the Chemistry Program will manage the applicable aging effects, where the GALL item references "Closed Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program/activity. Additionally, the attributes of this program/activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0014), Letdown - Tubes

PB, HT Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.3

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0014), Letdown - Tubes

PB, HT Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.3

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant

Page 254: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 254 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0014), Letdown - Tubesheet(s)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0014), Letdown - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchangers (XPP0043A/B/C-HE1), Charging/SI Pump Lube Oil Cooler - Shell

PB Stainless Steel Lube Oil None Identified None Identified None Required See Note A-CS-e

VIII.G.5-d N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE1), Charging/SI Pump Lube Oil Cooler - Shell

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE1),

PB Copper-Nickel Lube Oil None Identified None Identified None Required See Note A-CS-u

VII.G.7-b N.3-05 Yes, detection of aging effects is to be

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The

Page 255: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 255 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Charging/SI Pump Lube Oil Cooler - Tubes

evaluated component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE1), Charging/SI Pump Lube Oil Cooler - Tubes

PB Copper-Nickel Treated Water

Crevice Corrosion, Erosion-Corrosion, Galvanic Corrosion, Pitting Corrosion

Loss of Material Chemistry Program, Heat Exchanger Inspections

See Note A-CS-v, See Note A-CS-w

VII.E1.8-b, VII.E1.8.3

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in environment. VCSNS determined that cracking due to stress corrosion cracking and cyclic loading are not aging effects requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program/activity. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchangers (XPP0043A/B/C-HE1), Charging/SI Pump Lube Oil Cooler - Tubesheet(s)

PB Stainless Steel Lube Oil None Identified None Identified None Required See Note A-CS-e

VIII.G.5-d N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE1), Charging/SI Pump Lube Oil Cooler - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchangers (XPP0043A/B/C-HE2), Gearbox Lube Oil Cooler - Shell

PB Stainless Steel Lube Oil None Identified None Identified None Required See Note A-CS-e

VIII.G.5-d N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of

Page 256: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 256 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE2), Gearbox Lube Oil Cooler - Shell

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE2), Gearbox Lube Oil Cooler - Tubes

PB Stainless Steel Lube Oil None Identified None Identified None Required See Note A-CS-e

VIII.G.5-d N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE2), Gearbox Lube Oil Cooler - Tubes

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchangers (XPP0043A/B/C-HE2), Gearbox Lube Oil Cooler - Tubesheet(s)

PB Stainless Steel Lube Oil None Identified None Identified None Required See Note A-CS-e

VIII.G.5-d N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Heat Exchangers (XPP0043A/B/C-HE2), Gearbox Lube Oil Cooler - Tubesheet(s)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

VII.E1.8-b, VII.E1.8.2

T.3-09 Yes, plant specific No VII.E1.8-b addresses Letdown Heat Exchanger components. The component /component type AMR results are consistent with the identified GALL item in material and environment. VCSNS determined that cracking due to cyclic loading is not an aging effect requiring management for this component/component type. However, the identified GALL item recommends plant specific evaluation of the credited program.

Page 257: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 257 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

CS CS Instrumentation (Pressure Retaining Only) - (IFT0113)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Instrumentation (Pressure Retaining Only) - (IFT0113)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Instrumentation (Pressure Retaining Only) - (ILG17556A/B/C)

PB Glass Lube Oil None Identified None Identified None Required TR00160-010, Attachment V

N/A N.3-23 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Instrumentation (Pressure Retaining Only) - (ILG17556A/B/C)

PB Glass Sheltered None Identified None Identified None Required TR00160-010, Attachment X

N/A N.3-23 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Accumulators (XPP0043A/B/C-OR1), Charging/SI Pump Lube Oil Reservoir

PB Cast Iron Lube Oil None Identified None Identified None Required See Note A-CS-q

N/A N.3-05 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Accumulators PB Cast Iron Sheltered Boric Acid Corrosion Loss of Material Boric Acid See Note A- VII.I.1-a, T.3-14 No Yes VII.I.1-a addresses external surfaces of

Page 258: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 258 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(XPP0043A/B/C-OR1), Charging/SI Pump Lube Oil Reservoir

(Aggressive Chemical Attack)

Corrosion Surveillances

CS-o, See Note A-CS-p

VII.I.1.1 carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging effects as carbon steel, if both materials were exposed to a sheltered environment. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Orifices (CS) PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.2-c, V.D1.2.3

T.2-08, T.2-15, N.3-06A

Yes, plant specific No V.D1.2-c addresses Emergency Core Cooling System components. The component /component type AMR results are consistent with the identified GALL item in material and environment, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. VCSNS considers the loss of material due to erosion of mini-flow orifices to be a design problem rather than a valid aging-related effect/mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CV Orifices (CV) PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

T.2-15, N.3-06

No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent

Page 259: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 259 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the pertinent GALL program. CS CS Orifices PB, TH Stainless Steel Reactor

Building None Identified None Identified None Required TR00160-010,

Attachment IXV.C.1-b N.2-01,

N.3-01Yes, plant specific No V.C.1-b addresses containment isolation

components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pipe and Fittings PB Carbon Steel Lube Oil None Identified None Identified None Required See Note A-CS-h

VII.G.7-b N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

V.E.1-a, V.E.1.1

T.2-17, T.3-14

No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

T.2-15, N.3-06

No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program.

Page 260: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 260 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CV Pipe and Fittings (CV) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pipe and Fittings (CS) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

V.D1.5-a, V.D1.5.2

T.2-15, N.3-17

No Partial V.D1.5-a addresses Emergency Core Cooling System components. VCSNS determined that the Chemistry Program will manage the applicable aging effects, where the GALL item references "Closed Cycle Cooling Water System." Except as noted, the AMR results for this component/component type are consistent with the identified GALL item, which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CS Pumps (Bearing PB Carbon Steel Lube Oil None Identified None Identified None Required See Note A- VII.G.7-b N.3-05 Yes, detection of aging No VII.G.7-b addresses Reactor Coolant Pump

Page 261: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 261 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Housings) (XPP0043A/B/C), Charging/SI

CS-h effects is to be evaluated

Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pumps (Bearing Housings) (XPP0043A/B/C), Charging/SI

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

V.E.1-a, V.E.1.1

T.2-17, T.3-14

No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Pumps (Casing Only) (XPP0013A,B), Boric Acid Transfer

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.5-a, VII.E1.5.1

T.2-15, T.3-04

Yes, plant specific No VII.E1.5-a addresses Chemical and Volume Control System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CS Pumps (Casing Only) (XPP0013A,B), Boric Acid Transfer

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pumps (Casing Only) (XPP0043A/B/C), Charging/SI

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

VII.E1.5-a, VII.E1.5.1

T.2-15, T.3-04

Yes, plant specific No VII.E1.5-a addresses Chemical and Volume Control System components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects

Page 262: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 262 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CS Pumps (Casing Only) (XPP0043A/B/C), Charging/SI

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pumps (Casing Only) (XPP0043A/B/C-PP1, 2, 3), Charging/SI Auxiliaries

PB Carbon Steel Lube Oil None Identified None Identified None Required See Note A-CS-h

VII.G.7-b N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Pumps (Casing Only) (XPP0043A/B/C-PP1, 2, 3), Charging/SI Auxiliaries

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

V.E.1-a, V.E.1.1

T.2-17, T.3-14

No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Tanks (XTK0012A/B), Boric Acid

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited

Page 263: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 263 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Tanks (XTK0012A/B), Boric Acid

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tanks (XTK0012A/B), Boric Acid

PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-CS-f

VII.F3.4-a N.3-01 Yes, plant specific No VII.F3.4-a addresses Primary Containment Heating & Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tank (XTK0046), Volume Control (VCT)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

N.3-06 No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Tank (XTK0046), Volume Control (VCT)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.3-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion;

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See

V.D1.1-a, V.D1.1.5

T.2-15, N.3-06

No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material,

Page 264: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 264 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Stress Corrosion Cracking (SCC)

Note A-CS-b environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Tube & Tube Fittings PB Stainless Steel Lube Oil None Identified None Identified None Required See Note A-CS-e

VIII.G.5-d N.3-05 Yes, plant specific No VIII.G.5-d addresses Auxiliary Feedwater System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tube & Tube Fittings (ILT0112, ILT0115)

PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the

Page 265: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 265 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Tube & Tube Fittings (ILT0112, ILT0115)

PB Stainless Steel Treated Water

None Identified None Identified None Required See Note A-CS-c, See Note A-CS-d

V.C.1-b N.2-06 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Valves (Body Only) PB Carbon Steel Lube Oil None Identified None Identified None Required See Note A-CS-h

VII.G.7-b N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-CS-ii, See Note A-CS-j

V.E.1-a, V.E.1.1

T.2-17, T.3-14

No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CV Valves (Body Only) PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-a, See Note A-CS-b

V.D1.1-a, V.D1.1.5

T.2-15, N.3-06

No Yes V.D1.1-a addresses Emergency Core Cooling System components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the

Page 266: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 266 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-CS-g

V.C.1-b N.2-01, N.3-01

Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

CS CS Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-CS-c, See Note A-CS-d

V.D1.5-a, V.D1.5.2

T.2-15, N.3-17

No Partial V.D1.5-a addresses Emergency Core Cooling System components. The material, environment and aging effect requiring management for this component/component type are consistent with the identified GALL item, which has the same material, environment and aging effect. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

CS CS Filters PB, FI Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-ii, See Note A-CS-j

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

CS CS Filters PB, FI Cast Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-o, See Note A-CS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging

Page 267: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 267 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effects as carbon steel, if both materials were exposed to a sheltered environment. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Gearboxes (XPP0043A/B/C-GB), Charging/SI Pumps

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-ii, See Note A-CS-j

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0009), Excess Letdown - Shell

PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-k, See Note A-CS-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger (XHE0011), Seal Water - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-ii, See Note A-CS-j

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Accumulators (XPP0043A/B/C-OR1), Charging/SI Pump Lube Oil Reservoir

PB Cast Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-o, See Note A-CS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging effects as carbon steel, if both materials were exposed to a sheltered environment. The component /component type AMR results are consistent with the identified GALL item in

Page 268: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 268 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-ii, See Note A-CS-j

V.E.1-b, V.E.1.1

T.2-10, T.3-05

Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Pumps (Bearing Housings) (XPP0043A/B/C), Charging/SI

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-ii, See Note A-CS-j

V.E.1-b, V.E.1.1

T.2-10, T.3-05

Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Pumps (Casing Only) (XPP0043A/B/C-PP1, 2, 3), Charging/SI Auxiliaries

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-ii, See Note A-CS-j

V.E.1-b, V.E.1.1

T.2-10, T.3-05

Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

CS CS Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CS-ii, See Note A-CS-j

V.E.1-b, V.E.1.1

T.2-10, T.3-05

Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component /component type AMR results are consistent with the identified GALL item in material, environment and aging mechanism. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CS CS Heat Exchanger PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for See Note A- VII.I.1-b, T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of

Page 269: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 269 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(XHE0014), Letdown - Shell

Mechanical Components

CS-ii, See Note A-CS-j

VII.I.1.1 carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Channel Head

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-a See Note A-CC-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Heat Exchangers (XHE0002A/B), Component Cooling - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-a See Note A-CC-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

CC CC Motors (MPP0001A/B/C), CC Pump Casing/Int. Bearing Cooler only - Water Boxes

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-a See Note A-CC-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-m See Note A-CC-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 270: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 270 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation.

CC CC Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-CC-a See Note A-CC-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Another aging effect managed by the referenced program is microbiologically induced corrosion (MIC). However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Pumps (Casing Only) (XPP0001A/B/C), CC Pumps

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-a See Note A-CC-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Tank (XTK0003), CC Surge Tank

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-a See Note A-CC-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-m See Note A-CC-n

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

CC CC Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-CC-a See Note A-

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are

Page 271: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 271 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

CC-b consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WG CC Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-WG-c See Note A-WG-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. Certain aging effects not addressed by the GALL items are also managed by the credited activity. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Pumps (Casing Only) (XPP0048A/B/C), Chilled Water

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Shells

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in

Page 272: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 272 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

meeting the intent of the pertinent GALL program.

VU VU Condensers (XHX0001A/B/C-CN1), Chilled Water Unit - Water boxes

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Shells

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Evaporators (XHX0001A/B/C-EV1), Chilled Water Unit - Water boxes

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Compressors (XHX0001A/B/C-GC1),

PB Cast Iron Sheltered Boric Acid Corrosion (Aggressive Chemical

Loss of Material Boric Acid Corrosion

See Note A-VU-j

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. Cast iron is similar

Page 273: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 273 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Chilled Water Unit - Housing Only

Attack) Surveillances to carbon steel in composition and would be expected to experience the same aging effects as carbon steel, if both materials were exposed to a sheltered environment. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Flow Control Chambers (XHX0001A/B/C-PS1), Chilled Water Unit

PB, TH Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Pumps (XPP0186A/B/C), Chilled Water Cleanup System Fluid Ejector

PB, GR Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Eductor, Chilled Water Lubrication System

PB, GR Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring

Page 274: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 274 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Pumps (Casing Only) (XHX0001A/B/C-PP1, 2, 3, 4) - Chilled Water Unit Lubrication System

PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Pumps (Casing Only) (XHX0001A/B/C-PP1, 2, 3, 4) - Chilled Water Unit Lubrication System

PB Cast Iron Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-j

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. Cast iron is similar to carbon steel in composition and would be expected to experience the same aging effects as carbon steel, if both materials were exposed to a sheltered environment. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring

Page 275: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 275 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Purge Units (XHX0001A/B/C-GS1) - Chilled Water Purge System

PB, GR Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

VU VU Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-VU-a

VII.I.1-a, VII.I.1.1

T.3-14 No Yes VII.I.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EF EF Filter (TPP0008-FL1), EFWP Turbine Lube Oil Filter

PB, FI Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the

Page 276: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 276 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Heat Exchanger (TPP0008-HE1), EFWP Turbine Lube Oil Cooler - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Orifices (Breakdown) PB, TH Carbon Steel/Alloy Steel

Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Orifices (Flow) PB, TH Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Pipe and Fittings, EFWP Turbine Lube Oil

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in

Page 277: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 277 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Pump (Casing Only) (TPP0008-PP1) - EFWP Lube Oil Rotary Pump

PB Cast Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-s See Note A-EF-t

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No This material/environment combination is not addressed in GALL. However, because of similarities in material properties, the aging effects evaluated for cast iron are the same as those for carbon steel [TR00160-010, Attachment X]. VIII.H.1-b addresses carbon steel components (external surfaces). The component/component type AMR results are consistent with the identified GALL items in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Pump (Casing Only) (XPP0008), EFWP Turbine Driven

PB Alloy Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Pumps (Casing Only) ( XPP0021A/B), MDEFWP

PB Alloy Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Accumulator (TPP0008-OR1), EFWP Turbine Lube Oil Reservoir

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the

Page 278: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 278 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Valves (Body Only) - EFWP Turbine Lube Oil

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-e See Note A-EF-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EF EF Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EF-n See Note A-EF-o

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL items in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

EX EX Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-EX-a, See Note A-EX-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited activity. Additionally, the attributes of this activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 279: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 279 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. EX EX Pipe and Fittings PB Carbon Steel Treated

Water Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-EX-c, See Note A-EX-d

VIII.C.1-b, VIII.C.1.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.C.1-b addresses Extraction Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EX EX Valves (Body Only) PB Alloy Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EX-a, See Note A-EX-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

EX EX Valves (Body Only) PB Alloy Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-EX-c, See Note A-EX-d

VIII.C.1-a, VIII.C.1.1

T.4-06 No Yes VIII.C.1-a addresses Extraction Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

EX EX Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-EX-a, See Note A-EX-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect.

Page 280: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 280 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

EX EX Valves (Body Only) PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-EX-c, See Note A-EX-d

VIII.C.1-a, VIII.C.1.1

T.4-06 No Yes VIII.C.1-a addresses Extraction Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MB MB Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MB-a, See Note A-MB-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MB MB Pipe and Fittings PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-MB-c, See Note A-MB-d

VIII.B1.1-c, VIII.B1.1.4

T.4-06 No Yes VIII.B1.1-c addresses Main Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MB MB Tube & Tube Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MB-a, See Note A-MB-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are

Page 281: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 281 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MB MB Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MB-a, See Note A-MB-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MB MB Valves (Body Only) PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-MB-c, See Note A-MB-d

VIII.B1.2-b, VIII.B1.2.1

T.4-06 No Yes VIII.B1.2-b addresses Main Steam System valve bodies. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS EF Turbine (Casing/Shell Only) (TPP0008), EFWP

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MS-a, See Note A-MS-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS MS Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MS-e, See Note A-MS-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item

Page 282: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 282 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS MS Pipe and Fittings PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-MS-c, See Note A-MS-d

VIII.B1.1-c, VIII.B1.1.3

T.4-06 No Yes VIII.B1.1-c addresses Main Steam System piping and fittings. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MS-e, See Note A-MS-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS MS Valves (Body Only) PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-MS-c, See Note A-MS-d

VIII.B1.2-b, VIII.B1.2.1

T.4-06 No Yes VIII.B1.2-b addresses Main Steam System valve bodies. The material, environment, aging effects requiring management, and the credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MS-a, See Note A-MS-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management, and the credited activity for this

Page 283: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 283 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

component/component type are consistent with the identified GALL item which has the same material, environment, aging effect, and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AC AC Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AC-a See Note A-AC-b

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this credited activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AC AC Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AC-c See Note A-AC-d

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AC AC Valves (Body Only) PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AC-a See Note A-AC-b

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes

Page 284: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 284 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this credited activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AC AC Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AC-c See Note A-AC-d

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this credited activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AS AS Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AS-a See Note A-AS-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

AS AS Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-AS-a See Note A-AS-b

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 285: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 285 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BD BD Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-BD-a, See Note A-BD-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

BD BD Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-BD-c, See Note A-BD-d

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

BD BD Pipe and Fittings PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-BD-e, See Note A-BD-f

VIII.F.1-a, VIII.F.1.1

T.4-06 No Yes VIII.F.1-a addresses Steam Generator Blowdown System piping and fittings. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

BD BD Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-BD-a, See Note A-BD-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during

Page 286: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 286 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the period of extended operation. BD BD Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for

Mechanical Components

See Note A-BD-c, See Note A-BD-d

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

BD BD Valves (Body Only) PB Carbon Steel Treated Water

Erosion-Corrosion Loss of Material Flow Accelerated Corrosion Monitoring Program

See Note A-BD-e, See Note A-BD-f

VIII.F.2-a, VIII.F.2.1

T.4-06 No Yes VIII.F.2-a addresses Steam Generator Blowdown System valve bodies. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FW FW Flow Venturi (IFE0476, IFE0486, IFE0496), SG Feedwater Flow

PB, TH Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FW-a See Note A-FW-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FW FW Flow Venturi (IFE0476, IFE0486, IFE0496), SG Feedwater Flow

PB, TH Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-FW-c See Note A-FW-d

VIII.D1.1-c, VIII.D1.1.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.D1.1-c addresses Feedwater System piping and fittings. VCSNS determined that the Chemistry Program will manage loss of material where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not

Page 287: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 287 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FW FW Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FW-e See Note A-FW-f

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FW FW Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-FW-a See Note A-FW-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FW FW Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-FW-c See Note A-FW-d

VIII.D1.1-c, VIII.D1.1.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.D1.1-c addresses Feedwater System piping and fittings. VCSNS determined that the Chemistry Program will manage loss of material where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL

Page 288: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 288 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

FW FW Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FW-a See Note A-FW-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

FW FW Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-FW-c See Note A-FW-d

VIII.D1.2-b, VIII.D1.2.1

T.4-02 Yes, detection of aging effects is to be evaluated

Partial VIII.D1.2-b addresses Feedwater System valve bodies. VCSNS determined that the Chemistry Program will manage loss of material where the GALL item references the Chemistry Program and a One-Time Inspection. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, environment, and aging effects. Certain aging effects not addressed by the GALL item are also managed by the credited program. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Chemistry Program with a One-Time Inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

HR HR Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-HR-a See Note A-HR-b

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 289: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 289 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

HR HR Recombiners (XHR0004A/B) - Electric, H2

HT Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-HR-c See Note A-HR-d

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

HR HR Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-HR-a See Note A-HR-b

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SW SW Couplings PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-SW-e

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SW SW Expansion Joints, Mechanical

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical

See Note A-SW-e

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The

Page 290: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 290 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(XEJ0040A/B, 41A/B) - piping

Components component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SW SW Pipe and Fittings PB Carbon Steel Reactor Building

Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-SW-g

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SW SW Pipe and Fittings PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-SW-e

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SW SW Pumps (Casing Only) ( XPP0045A/B), SW Booster Pumps

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-SW-e

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively

Page 291: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 291 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

managing aging during the period of extended operation.

SW SW Pumps (Casing Only) (XPP0039AB/C), SW Pumps

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-SW-e

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SW SW Valves (Body Only) PB Carbon Steel Reactor Building

Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-SW-g

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SW SW Valves (Body Only) PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-SW-e

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Eductor, Chilled Water Lubrication System

PB, GR Stainless Steel Oil None Identified None Identified None Required See Note A-VU-q

VIII.G.5-d N.3-05 Yes, plant specific No GALL Item No. VIII.G.5-d addresses bearing oil coolers. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 292: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 292 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

VU VU Pumps (Casing Only) (XHX0001A/B/C-PP1, 2, 3, 4) - Chilled Water Unit Lubrication System

PB Carbon Steel Oil None Identified None Identified None Required See Note A-VU-p

VII.G.7-a N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

MS MS Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MS-a, See Note A-MS-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

DG DG Filters (XEG0001A/B-FL5)

PB, FI Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Pipe and Fittings PB Brass Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-t See Note A-DG-u

N/A N.3-27 N/A N/A The brass and fuel oil combination is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type, are therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

DG DG Pipe and Fittings PB Carbon Steel Fuel Oil Microbiologically Loss of Material Chemistry See Note A- VII.H1.4-a, T.3-07 Yes, detection of aging Partial VII.H1.4-a addresses Diesel Fuel Oil System

Page 293: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 293 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Induced Corrosion (MIC)

Program DG-o VII.H1.4.1 effects is to be evaluated

components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Tube & Tube Fittings PB Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

DG DG Valves (Body Only) PB Carbon Steel Fuel Oil Microbiologically Induced Corrosion (MIC)

Loss of Material Chemistry Program

See Note A-DG-o

VII.H1.4-a, VII.H1.4.1

T.3-07 Yes, detection of aging effects is to be evaluated

Partial VII.H1.4-a addresses Diesel Fuel Oil System components. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effects and program (VCSNS Fuel Oil Chemistry included in Chemistry Program), except that VCSNS found that heat exchanger biofouling and loss of material due to general, crevice and pitting corrosion are not aging effects requiring management for

Page 294: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 294 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the subject component. However, the attributes of the credited program are not fully consistent with the corresponding program attributes as described in GALL Chapter XI because the GALL item recommends augmentation of the Fuel Oil Chemistry Program with a One-Time inspection. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-MS-a, See Note A-MS-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS EF Valve (Body Only) (XVM11025-EF), EFWP Turbine Governor

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MS-a, See Note A-MS-b

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VU VU Pumps (Casing Only) (XHX0001A/B/C-PP1, 2, 3, 4) - Chilled Water Unit Lubrication System

PB Cast Iron Oil None Identified None Identified None Required See Note A-VU-r

VII.G.7-a N.3-05 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

VU VU Filters - Chilled Water Lubrication System

PB, FI Stainless Steel Oil None Identified None Identified None Required See Note A-VU-q

VIII.G.5-d N.3-05 Yes, plant specific No GALL Item No. VIII.G.5-d addresses bearing oil coolers. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during

Page 295: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 295 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the period of extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Black Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-FS-o, See Note A-FS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an additional aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FS-r, See Note A-FS-s

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-FS-o, See Note A-FS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect with the identification of an additional aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Pumps (Casing Only) (XPP0134A/B), Electric & Diesel Fire Pump

PB Cast Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FS-o, See Note A-FS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. There are material similarities between cast iron and carbon steel. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during

Page 296: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 296 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the period of extended operation. FS FS Strainer (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for

Mechanical Components

See Note A-FS-o, See Note A-FS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FS-r, See Note A-FS-s

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FS-o, See Note A-FS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Valves (Body Only) PB Cast Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-FS-o, See Note A-FS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. There are material similarities between cast iron and carbon steel. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-IA-c See Note A-IA-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item

Page 297: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 297 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Pipe and Fittings PB Carbon Steel Sheltered General Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-IA-e See Note A-IA-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Tanks PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-IA-e See Note A-IA-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components.. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-IA-c See Note A-IA-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-IA-e See Note A-IA-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

IA IA Valves (Body Only) PB Cast Iron Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-IA-b See Note A-

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. Cast iron is similar to carbon steel in composition and would be

Page 298: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 298 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

IA-o expected to experience the same aging effects as carbon steel. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SA SA Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SA-c See Note A-SA-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SA SA Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SA-e See Note A-SA-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SA SA Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SA-c See Note A-SA-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses carbon steel external surfaces. The component/component type AMR results are consistent with the identified GALL items in material, environment, and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

SA SA Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SA-e See Note A-SA-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for

Page 299: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 299 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

BS BS Tube & Tube Fittings PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-BS-e See Note A-BS-g

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. An additional VCSNS aging effect includes galvanic corrosion. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

NG NG Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-NG-a See Note A-NG-b

V.C.1-a, V.C.1.2

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and aging effect. Relative to environment, the identified GALL item and component/component type consider the same external environment, but reference different internal environments. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

NG NG Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-NG-d See Note A-NG-e

V.C.1-a, V.C.1.2

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and aging effect. Relative to environment, the identified GALL item and component/component type consider the same external environment, but reference different internal environments. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

NG NG Valves (Body Only) PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-NG-a See Note A-NG-b

V.C.1-a, V.C.1.1

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and aging effect. Relative to environment, the identified GALL item and component/component type consider the same external environment, but reference different internal environments.

Page 300: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 300 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

NG NG Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-NG-d See Note A-NG-e

V.C.1-a, V.C.1.1

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and aging effect. Relative to environment, the identified GALL item and component/component type consider the same external environment, but reference different internal environments. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

LR LR Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-LR-a See Note A-LR-b

V.C.1-a, V.C.1.2

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and aging effect. Relative to environment, the identified GALL item and component/component type consider the same external environment, but reference different internal environments. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

LR LR Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-LR-c See Note A-LR-d

V.C.1-a, V.C.1.2

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and aging effect. Relative to environment, the identified GALL item and component/component type consider the same external environment, but reference different internal environments. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

LR LR Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-LR-c See Note A-LR-d

V.C.1-a, V.C.1.1

T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and aging

Page 301: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 301 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effect. Relative to environment, the identified GALL item and component/component type consider the same external environment, but reference different internal environments. However, the identified GALL items recommend plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Expansion Joints, Mechanical (retaining rings)

PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-a, See Note A-AH-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAA-1A/B, -2A/B-AH) - RBCUs

PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-a, See Note A-AH-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAH-12A/B-AH) - Control Room

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAH-13A/B-AH) - Relay Room

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of an aging effect requiring

Page 302: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 302 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Handling Units (XAH-24A/B-AH) - Battery Room/Charging Room

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Air Plenums (FH Building and CR Emergency Filter Plenums)

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAH-12A/B, -13A/B, -24A/B-AH) - Headers

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Ductwork PB Galvanized Steel

Sheltered Galvanic Corrosion, Microbiologically

Loss of Material Inspections for Mechanical

See Note A-AH-k, See

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. For this

Page 303: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 303 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Induced Corrosion (MIC)

Components, Maintenance Rule Structures Program

Note A-AH-l environment, there are similarities between carbon steel and galvanized steel. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of aging effects requiring management that are not addressed in GALL for this item. . However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Ductwork (fan housings and plenum housings)

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Heating Coils (XHC-2A/B, -3A/B, -14A/B-AH)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Pipe - RBCU Cooling Coil Manifold

PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-a, See Note A-AH-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging

Page 304: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 304 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

during the period of extended operation. AH AH Valves (Body Only)

(XVB-1A, -2A, -3A/B, -4A/B-AH)

PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-AH-k, See Note A-AH-l

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effects, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Valves (Body Only) (XVB-1B, -2B-AH)

PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-a, See Note A-AH-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XHR0003A/B-HE1), Helical - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WG-c See Note A-WG-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Shell

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WG-c See Note A-WG-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WG WG Heat Exchangers (XGC0001A/B-HE1), Waste Gas Compressor - Channel Head

PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WG-c See Note A-WG-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in

Page 305: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 305 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WG WG Tube & Tube Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WG-c See Note A-WG-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

WG WG Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-WG-c See Note A-WG-d

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SI SI Pipe and Fittings PB Stainless Steel Air-Gas (Moist)

None Identified None Identified None Required See Note A-SI-h

N/A N.2-01 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SI SI Valves (Body Only) PB Stainless Steel Air-Gas (Moist)

None Identified None Identified None Required See Note A-SI-h

N/A N.2-01 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

BR BR Heat Exchanger (XEV0008-HE2), Recycle Evaporator - Shell

PB Carbon Steel/Stainless Steel Combination

Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-BR-a, See Note A-BR-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited activity. Refer to TR00160-020 for a detailed discussion of the attributes of this

Page 306: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 306 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

activity in effectively managing aging during the period of extended operation.

BR BR Condensers (XEV0008-CN1, XEV0008-CN2), Recycle Evaporator - Channel Head

PB Carbon Steel/Stainless Steel Combination

Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-BR-a, See Note A-BR-b

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited activity. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-01A/B-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Unit (XAH-02-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-04A/B-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended

Page 307: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 307 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

operation. VL VL Air Handling Unit (XAH-

06-VL) PB Galvanized

Steel Sheltered Galvanic Corrosion Loss of Material Inspections for

Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Unit (XAH-08-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-09A/B-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-11A/B-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing

Page 308: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 308 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

aging during the period of extended operation.

VL VL Air Handling Units (XAH-19A/B-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

VL VL Air Handling Units (XAH-32-VL, XAH-33-VL)

PB Galvanized Steel

Sheltered Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect with the identification of an aging effect requiring management that is not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

VL VL Cooling Coils - Headers PB Carbon Steel Sheltered Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

VL VL Ductwork (including fire damper housings)

PB Galvanized Steel

Sheltered Galvanic Corrosion, Microbiologically Induced Corrosion (MIC)

Loss of Material Inspections for Mechanical Components, Maintenance Rule Structures Program

See Note A-VL-a See Note A-VL-f

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified

Page 309: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 309 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Fins

HT Copper Ventilation Boric Acid Corrosion (Aggressive Chemical Attack), Galvanic Corrosion; Particulates

Heat Exchanger Fouling, Loss of Material

Preventive Maintenance Activities - Ventilation Systems Inspections

See Notes A-AH-h, A-AH-ii

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Tubes

PB, HT Copper Ventilation Boric Acid Corrosion (Aggressive Chemical Attack), Galvanic Corrosion; Particulates

Loss of Material; Heat Exchanger Fouling

Preventive Maintenance Activities - Ventilation Systems Inspections

See Notes A-AH-h, A-AH-ii

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

RC1b RC Upper Support Plate Assembly

2 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.1-a, IV.B2.1.1

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effects/mechanisms requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the VCSNS Chemistry Program. Additionally, the attributes of the Chemistry Program, as it

Page 310: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 310 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2) . The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Upper Support Plate Assembly

2 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-b, IV.B2.1.1

T.1-11 Yes, Plant Specific No Except as noted, the sub-component AMR results are consistent with the identified GALL item which has essentially the same material, environment, aging effect requiring management and credited program. Sub-component material is Stainless Steel, whereas the GALL item lists both Sainless Steel and Nickel-Based alloy. Additionally, the GALL item recommends plant specific evaluation even though a corresponding program, addressing void swelling, is evaluated in GALL Chapter XI (XI.M16). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program attributes (XI.M16) as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a discussion of the attributes of the program in effectively managing aging during the period of extended operation.

RC1b RC Upper Support Columns 2, 4 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC),

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.1-e, IV.B2.1.2

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging

Page 311: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 311 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Irradiation Assisted Stress Corrosion Cracking (IASCC)

effects/mechanisms requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the VCSNS Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Upper Support Columns 2, 4 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-f, IV.B2.1.2

T.1-11 Yes, Plant Specific No Except as noted, the sub-component AMR results are consistent with the identified GALL item which has essentially the same material, environment, aging effect requiring management and credited program. Sub-component material is Stainless Steel, whereas the GALL item lists both Sainless Steel and Nickel-Based alloy. Additionally, the GALL item recommends plant specific evaluation even though a corresponding program, addressing void swelling, is evaluated in GALL Chapter XI (XI.M16). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program attributes (XI.M16) as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a discussion of the attributes of the program in effectively

Page 312: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 312 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

managing aging during the period of extended operation.

RC1b RC Upper Support Column Bolts

2, 4 Stainless Steel (Type 316)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-j, IV.B2.1.3

T.1-11 Yes, Plant specific No Except as noted, the sub-component AMR results are consistent with the identified GALL item which has essentially the same material, environment, aging effect requiring management and credited program. Sub-component material is Stainless Steel, whereas the GALL item lists both Sainless Steel and Nickel-Based alloy. Additionally, the GALL item recommends plant specific evaluation even though a corresponding program, addressing void swelling, is evaluated in GALL Chapter XI (XI.M16). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program attributes (XI.M16) as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a discussion of the attributes of the program in effectively managing aging during the period of extended operation.

RC1b RC Upper Support Column Bolts

2, 4 Stainless Steel (Type 316)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.1-i, IV.B2.1.3

T.1-45, N.1-07

No Partial GALL item IV.B2.1-i is referred to herein as IV.B2.1-ii due to an MS Access quirk. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effects/mechanisms requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the VCSNS Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2) . The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection meets the intent of the corresponding GALL

Page 313: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 313 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Chapter XI program (XI.M16) attributes as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Upper Support Column Bolts

2, 4 Stainless Steel (Type 316)

Borated Water

Stress Relaxation Loss of Preload Reactor Vessel Internals Inspection

See Note A-RC1b-g.

IV.B2.1-k, IV.B2.1.3

T.1-48 No Partial Except as noted, the sub-component AMR results are consistent with the identified GALL item which has essentially the same material, environment, and aging effect requiring management. Sub-component material is Stainless Steel, whereas the GALL item lists both Sainless Steel and Nickel-Based alloy. Additionally, the GALL item recommends a combination of "ISI" (XI.M1) and "Loose Parts Monitoring" (XI.M14) programs for aging management, whereas VCSNS credits the Reactor Vessel Internals Inspection. The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program attributes (XI.M16) as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a discussion of the attributes of the program in effectively managing aging during the period of extended operation.

RC1b RC Upper Core Plate (UCP) 1, 3 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-b, IV.B2.1.4

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020

Page 314: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 314 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Upper Core Plate (UCP) 1, 3 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.1-a, IV.B2.1.4

T.1-45, N.1-07

No Partial The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match. Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match".

RC1b RC Upper Core Plate Alignment Pins

1, 3 Stainless Steel (Type 304)

Borated Water

Wear Loss of Material Reactor Vessel Internals Inspection

See Note A-RC1b-f.

IV.B2.1-l, IV.B2.1.5

T.1-40 No Partial Material is SS, GALL list both SS and Ni alloy. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by

Page 315: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 315 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Upper Core Plate Alignment Pins

1, 3 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.1-i, IV.B2.1.5

T.1-45, N.1-07

No Partial Material is SS, GALL lists both SS and Ni alloy. The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match. Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match".

RC1b RC Upper Core Plate Alignment Pins

1, 3 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-j, IV.B2.1.5

T.1-11 Yes, Plant Specific No Material is SS, GALL list both SS and Ni alloy. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not

Page 316: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 316 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Core Plate Fuel Alignment Pins

1, 3, 4, 5

Stainless Steel (Type 316)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-f, IV.B2.5.2

T.1-11 Yes, Plant Specific No Material is SS, GALL list both SS and Ni alloy. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Core Plate Fuel Alignment Pins

1, 3, 4, 5

Stainless Steel (Type 316)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.5-g, IV.B2.5.2

T.1-43 No Partial Material is SS, GALL list both SS and Ni alloy. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

Page 317: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 317 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RC1b RC Holddown Spring 1 Stainless Steel (Type 403)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-b, IV.B2.1.7

T.1-11 No Partial Material is 403 SS, GALL list just SS. The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match. Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Holddown Spring 1 Stainless Steel (Type 403)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.1-a, IV.B2.1.7

T.1-45, N.1-07

No Partial Material is 403 SS, GALL list just SS. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program

Page 318: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 318 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes (XI.M2) . The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Holddown Spring 1 Stainless Steel (Type 403)

Borated Water

Stress Relaxation Loss of Preload Reactor Vessel Internals Inspection

See Note A-RC1-g

IV.B2.1-d, IV.B2.1.7

T.1-42 No Partial Material is 403 SS, GALL list just SS. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Guide Tubes 2 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.2-a, IV.B2.2.1

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the

Page 319: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 319 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Guide Tubes 2 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.2-b, IV.B2.2.1

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Guide Tube Bolts and Support Pins (Split Pins)

2 Stainless Steel (Type 316)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.2-d, IV.B2.2.2, IV.B2.2.3

T.1-45, N.1-07

No Partial Material is stainless steel, GALL item lists both stainless steel and Ni alloy. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it

Page 320: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 320 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Guide Tube Bolts and Support Pins (Split Pins)

2 Stainless Steel (Type 316)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.2-b, IV.B2.2.2

T.1-11 Yes, Plant specific No Material is SS, GALL list both SS and Ni alloy. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Core Barrel and Flange 1, 3, 6 Stainless Steel (Type 304)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.3-c, IV.B2.3.1

T.1-43 No Partial The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program

Page 321: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 321 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Core Barrel and Flange 1, 3, 6 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.3-a, IV.B2.3.1, IV.B2.3.3

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Core Barrel and Flange 1, 3, 6 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.3-b, IV.B2.3.1

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program

Page 322: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 322 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Core Barrel Outlet Nozzles

3 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.3-a, IV.B2.3.3

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Core Barrel Outlet Nozzles

3 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.3-b, IV.B2.3.3

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program

Page 323: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 323 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Core Barrel Outlet Nozzles

3 Stainless Steel (Type 304)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.3-c, IV.B2.3.3

T.1-43 No Partial The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Neutron Panels (Thermal Shields)

6 Stainless Steel (Type 304)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.3-c, IV.B2.3.4

T.1-43 No Partial The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Neutron Panels (Thermal 6 Stainless Steel Borated Crevice Corrosion, Loss of Material; Chemistry See Note A- IV.B2.3-a, T.1-45, No Partial Except as noted, the AMR results for this

Page 324: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 324 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Shields) (Type 304) Water Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Cracking Program; Reactor Vessel Internals Inspection

RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.3.4 N.1-07 sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Neutron Panels (Thermal Shields)

6 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.3-b, IV.B2.3.4

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Baffle and Former 1, 3, 6 Stainless Steel Borated Irradiation Reduction of Reactor Vessel See Note A- IV.B2.4-e, T.1-43 No Partial GALL items IV.B2.4-e addresses reduction of

Page 325: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 325 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Assembly (Type 304) Water Embrittlement Fracture Toughness

Internals Inspection

RC1b-e. IV.B2.4.1 fracture toughness of the baffle and former assembly. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited program. At VCSNS, void swelling is considered to result in changes in dimensions (distortion) and is not considered to separately result in both a reduction of fracture toughness and in changes in dimensions as is stated for GALL items IV.B2.4-e and IV.B2.4-b, even though the same activity is credited for management of both mechanisms. The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of applicable stainless steel RV Internals (EPRI MRP ITG). This inspection will include visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Baffle and Former Assembly

1, 3, 6 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.4-b, IV.B2.4.1

T.1-11 Yes, Plant Specific No GALL item IV.B2.4-b addresses void swelling of the baffle and former plates. The AMR results for this sub-component are consistent with the GALL item with respect to material, environment, aging effect requiring management, and credited program. However, the GALL item recommeds plant specific evaluation. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of applicable RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. Even though plant specific evaluation is recommended by the GALL item, the attributes of the Reactor Vessel Internals Inspection meet the intent of the

Page 326: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 326 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program (XI.M16) attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Baffle and Former Assembly

1, 3, 6 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.4-a, IV.B2.4.1

T.1-45, N.1-07

No Partial GALL items IV.B2.4-a addresses cracking of the baffle and former assembly. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Baffle and Former Assembly Bolts

1, 3, 6 Stainless Steel (Type 316)

Borated Water

Stress Relaxation Loss of Preload Reactor Vessel Internals Inspection

See Note A-RC1b-g.

IV.B2.4-h, IV.B2.4.2

T.1-16 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the

Page 327: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 327 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Baffle and Former Assembly Bolts

1, 3, 6 Stainless Steel (Type 316)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.4-f, IV.B2.4.2

T.1-06 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Baffle and Former Assembly Bolts

1, 3, 6 Stainless Steel (Type 316)

Borated Water

Void Swelling, Irradiation Creep

Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.4-d, IV.B2.4.2

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG), as well as irradiation creep of the baffle former bolts. This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Core Plate (LCP) 1, 3, 4, 5

Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-b, IV.B2.5.1

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program

Page 328: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 328 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Core Plate (LCP) 1, 3, 4, 5

Stainless Steel (Type 304)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.5-c, IV.B2.5.1

T.1-43 No Partial The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Core Plate (LCP) 1, 3, 4, 5

Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.5-a, IV.B2.5.1

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV

Page 329: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 329 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Lower Core Plate Fuel Alignment pins

1, 3, 4, 5

Stainless Steel (Type 316)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.5-e, IV.B2.5.2

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Upper Core Plate Fuel Alignment pins

1, 3 Stainless Steel (Type 316)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.1-i, IV.B2.1.6

T.1-45, N.1-07

No Partial Material is SS, GALL list both SS and Ni alloy. The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match.

Page 330: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 330 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Stress Corrosion Cracking (IASCC)

Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection program meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection program are at best a "Partial Match".

RC1b RC Lower Support Plate (LSP)

1, 3, 4, 5

Stainless Steel (Type 304)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.5-n, IV.B2.5.3

T.1-43 No Partial The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Support Plate (LSP)

1, 3, 4, 5

Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-l, IV.B2.5.3

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void

Page 331: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 331 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Support Plate (LSP)

1, 3, 4, 5

Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Notes A-RC1b-a, A-RC1b-b.

IV.B2.5-k, IV.B2.5.3

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Lower Support Columns 1, 4, 5 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-l, IV.B2.5.4

T.1-11 Yes, Plant Specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void

Page 332: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 332 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Support Columns 1, 4, 5 Stainless Steel (Type 304)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.5-n, IV.B2.5.4

T.1-43 No Partial The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Lower Support Columns 1, 4, 5 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.5-k, IV.B2.5.4

T.1-45, N.1-07

No Partial Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation

Page 333: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 333 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Lower Support Column Bolts

1, 4, 5 Stainless Steel (Type 316)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Notes A-RC1b-a, A-RC1b-b.

IV.B2.5-e, IV.B2.5.5

T.1-45, N.1-07

No Partial Material is SS, GALL list both SS and Ni alloy. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Lower Support Column Bolts

1, 4, 5 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals

See Note A-RC1b-d.

IV.B2.5-f, IV.B2.5.5

T.1-11 Yes, Plant Specific No Material is SS, GALL list both SS and Ni alloy. The Reactor Vessel Internals

Page 334: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 334 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Inspection Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Radial Keys 1 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.5-a, IV.B2.5.6

T.1-45, N.1-07

No Partial GALL list Radial keys and Clevis inserts together. Keys are SS as in GALL, GALL says the Inserts are SS but they are Alloy 600 at VCSNS. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation

Page 335: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 335 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

and in meeting the intent of the pertinent GALL programs.

RC1b RC Radial Keys 1 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-b, IV.B2.5.6

T.1-11 Yes, Plant Specific No GALL list Radial keys and Clevis inserts together. Keys are SS like GALL, GALL says the Inserts are SS but they are Alloy 600. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Radial Keys 1 Stainless Steel (Type 304)

Borated Water

Wear Loss of Material Reactor Vessel Internals Inspection

See Note A-RC1b-f.

IV.B2.5-o, IV.B2.5.6

T.1-40 No Partial GALL list Radial keys and Clevis inserts together. Keys are SS like GALL, GALL says the Inserts are SS but they are Alloy 600. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Clevis Inserts 1 Nickel-Based Alloy (Alloy 600)

Borated Water

Wear Loss of Material Reactor Vessel Internals Inspection

See Note A-RC1b-f.

IV.B2.5-o, IV.B2.5.6

T.1-40 No Partial GALL lists IV.B2.5-o, IV.B2.5.6 as SS for inserts however they are Alloy 600 at VCSNS. However, either material is susceptible to the identified aging effect. As

Page 336: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 336 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

such, the environment, aging effect requiring management, and credited program for the sub-component AMR result are consistent with the specified GALL item. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Clevis Inserts 1 Nickel-Based Alloy (Alloy 600)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-b, IV.B2.5.6

T.1-11 Yes, Plant Specific No GALL lists IV.B2.5-b, IV.B2.5.6 as SS for radial keys and clevis inserts, however they are Alloy 600 at VCSNS. However, the environment, aging effect requiring management, and credited program for this sub-component AMR result are consistent with the specified GALL item and nickel-based alloys are conservatively considered to demonstrate the same response to aging as stainless steel. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and/or Wear of susceptible RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes, except as clarified. However, the program is in not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Clevis Inserts 1 Nickel-Based Alloy (Alloy 600)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals

See Notes A-RC1b-c, A-RC1b-b

IV.B2.5-a, IV.B2.5.6

T.1-45, N.1-07

No Partial GALL lists IV.B2.5-a, IV.B2.5.6 as SS for clevis inserts, however they are Alloy 600 at VCSNS. As such the inserts are also

Page 337: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 337 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC); Primary Water Stress Corrosion Cracking (PWSCC)

Inspection susceptible to PWSCC. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanisms requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations and will also address PWSCC of the nickel-based alloy portions of the Reactor Internals. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b RC Clevis Inserts Bolts 1 Nickel-Based Alloy (X-750)

Borated Water

Stress Relaxation Loss of Preload Reactor Vessel Internals Inspection

See Note A-RC1b-g.

IV.B2.5-i, IV.B2.5.7

T.1-42 No Partial Material is Alloy X-750, GALL lists both SS and Ni alloy. Except as noted, the AMR results for this component type are consistent with the identified GALL item which has a similar material, environment, aging effect/mechanism and credited programs. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in

Page 338: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 338 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Clevis Inserts Bolts 1 Nickel-Based Alloy (X-750)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-f, IV.B2.5.7

T.1-11 Yes, Plant Specific No Material is Alloy X-750, GALL list both SS and Ni alloy. Except as noted, the AMR results for this component type are consistent with the identified GALL item which has a similar material, environment, aging effect/mechanism and credited program. Per the WCAP, the location of the clevis is such that irradiation embrittlement is not an issue and therefore void swelling, which is irradiation related is unlikely. However, conservatively, the specified program is credited for management. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Clevis Inserts Bolts 1 Nickel-Based Alloy (X-750)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC); Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-c, A-RC1b-b.

IV.B2.5-e, IV.B2.5.7

T.1-45, N.1-07

No Partial Material is Alloy X-750, GALL list both SS and Ni alloy. Except as noted, the AMR results for this component type are consistent with the identified GALL item which has a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it is applicable to Class 1 components, meet the intent of the corresponding GALL Chapter XI program (XI.M2) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 339: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 339 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Secondary Core Support 1, 3, 4, 5

Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.1-a T.1-45, N.1-07

No Partial Secondary Core Support is not listed in GALL compare to: IV B2.1-a, IV B2.1.1 for the Upper Support Plate. The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match. Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at

Page 340: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 340 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

best a "Partial Match". RC1b RC Secondary Core Support 1, 3, 4,

5 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-b, IV.B2.1.1

T.1-11 Yes, Plant Specific No Secondary Core Support is not listed in GALL compare to: IV.B2.1-b, IV.B2.1.1 for the Upper Support Plate. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Spray Nozzles 3 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.1-a, IV.B2.1.1

T.1-45, N.1-07

No Partial Spray Nozzles are not listed in GALL compare to: IV B2.1-a, IV B2.1.1 for the Upper Support Plate. The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match. Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program

Page 341: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 341 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match".

RC1b RC Spray Nozzles 3 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-b, IV.B2.1.1

T.1-11 Yes, Plant Specific No Spray Nozzles are not listed in GALL compare to: IV.B2.1-b, IV.B2.1.1 for the Upper Support Plate. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Upper Instrumentation Conduit and Supports

4 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-b, IV.B2.1.1

T.1-11 Yes, Plant Specific No Upper Instrumentation Columns are not listed in GALL. GALL item IV.B2.1-b addresses the identified aging effect for the Upper Support Plate. Except as noted, the sub-component AMR results are consistent with the identified GALL item which has essentially the same material, environment, aging effect requiring management and credited program. Additionally, the GALL item recommends plant specific evaluation even though a corresponding program, addressing void swelling, is evaluated in GALL Chapter XI (XI.M16). The Reactor Vessel Internals Inspection is a new activity, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program attributes (XI.M16) as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a

Page 342: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 342 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

discussion of the attributes of the program in effectively managing aging during the period of extended operation.

RC1b RC Upper Instrumentation Conduit and Supports

4 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.1-a, IV.B2.1.1

T.1-45, N.1-07

No Partial Upper Instrumentation Columns are not listed in GALL compare to: IV B2.1-a, IV B2.1.1 for the Upper Support Plate. The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match. Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match".

RC1b RC Head/Vessel Alignment Pins

2 Stainless Steel (Type 304)

Borated Water

Wear Loss of Material Reactor Vessel Internals Inspection

See Note A-RC1b-f.

IV.B2.5-o, IV.B2.5.6

T.1-40 No Partial Head and Vessel Alignment Pins are not listed in GALL compare to: IV B2.5-b, IV B2.5.6 for Radial Keys and Clevis Inserts. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will

Page 343: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 343 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Head/Vessel Alignment Pins

2 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.5-b, IV.B2.5.6

T.1-11 Yes, Plant Specific No Head and Vessel Alignment Pins are not listed in GALL compare to: IV B2.5-b, IV B2.5.6 for Radial Keys and Clevis Inserts. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Head/Vessel Alignment Pins

2 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.5-a T.1-45, N.1-07

No Partial Head and Vessel Alignment Pins are not listed in GALL. The material, environment, aging effect requiring management, and credited programs are consistent with GALL item IV B2.5-a which addresses cracking of stainless steel radial keys and clevis inserts. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which has similar material, environment, aging effect/mechanism requiring management and credited programs. Certain aging effects not addressed by the GALL (crevice and pitting corrosion) are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program, as it applies to the environments of Class 1 components, meets the intent of the corresponding GALL Chapter XI program attributes (XI.M2). The Reactor Vessel Internals Inspection is a new activity,

Page 344: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 344 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This inspection includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection, when developed, will meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes except as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 inch resolution suggested in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1b IC Instrumentation, Incore Thermocouples Seal

4, 7 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RC1b-a, A-RC1b-b.

IV.B2.1-e N.1-05, N.1-06

No Partial Incore Thermocouple seals are not listed in GALL. However, with respect to material, environment, aging effect requiring management, and credited program as clarified, the sub-component AMR results are consistent with GALL item IV.B2.1-e, particularly for the upper most portions of the upper support columns (IV.B2.1.2). Due to their location relative to the core, IASCC (as well as Void Swelling) is not considered a valid aging mechanism, as it is for the lower portions of the upper support columns. Certain aging effects (crevice and pitting corrosion) not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program (XI.M2) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

MU MU Tank (XTK0039), Reactor Makeup Water Storage

PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-MU-d

VII.F2.4-a, VII.F2.4.1

N.3-01 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SF RW Tank (XTK0025), Refueling Water Storage (RWST)

PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-SF-j

VII.F3.4-a N.2-01 Yes, plant specific No VII.F3.4-a addresses Ventilation System components. The component/component type AMR results are consistent with the

Page 345: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 345 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SS SS Tank (XTK0147), Flushing Water Storage

PB Stainless Steel Ventilation * None Identified None Identified None Required See Note A-SS-q

VII.F2.4-a, VII.F2.4.1

N.3-01 Yes, plant specific No VII.F2.4-a addresses Auxiliary and Radwaste Area Ventilation System components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1b RC Baffle and Former Assembly Bolts

1, 3, 6 Stainless Steel (Type 316)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Notes A-RC1b-a, A-RC1b-b.

IV.B2.4-c, IV.B2.4.2

T.1-15, N.1-07

Yes, Plant Specific No GALL item IV.B2.4-b addresses void swelling of the baffle and former plates. The AMR results for this sub-component are consistent with the GALL item with respect to material, environment, aging effect requiring management, and credited program. However, the GALL item recommeds plant specific evaluation. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of applicable RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. Even though plant specific evaluation is recommended by the GALL item, the attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Bottom Mounted Instrumentation (BMI) Columns

4 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Irradiation Assisted Stress Corrosion Cracking (IASCC)

Loss of Material; Cracking

Chemistry Program; Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.6-a, IV.B2.6.1

T.1-45, N.1-07

No Partial The Chemistry Program applicable to the Class 1 components is consistent with the criteria in Chapter XI.M2 of the GALL. Therefore, this program by itself is a match. Except as noted, the AMR results for this component type are consistent with the identified GALL items which have a similar material, environment, aging effect/mechanism and credited programs. Certain aging effects not addressed by the

Page 346: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 346 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection program meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection program are at best a "Partial Match".

RC1b RC Bottom Mounted Instrumentation (BMI) Columns

4 Stainless Steel (Type 304)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-a, A-RC1b-b.

IV.B2.6-b, IV.B2.6.1

T.1-11 Yes, plant specific No The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection program meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection program are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b IC Incore Neutron Detector (Flux) Thimbles (XD0004-IC) - Bottom Mounted Instrumentation

4, 7 Stainless Steel (Type 304)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RC1b-a, A-RC1b-b. A-RC1b-b

IV.B2.6-a N.1-07, N.1-11

No Partial BMI (flux) thimbles are listed in GALL only for item IV.B2.-c (IV.B2.6.2). However, with respect to material, environment, aging effect requiring management, and credited program as clarified, the sub-component AMR results are consistent with GALL item IV.B2.6-a, particularly for the lower most portions of the thimble guide tubes (IV.B2.6.1). Due to their location relative to the core, IASCC is not

Page 347: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 347 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

considered a valid aging mechanism, as it is for the upper portions of the thimble guide tubes. Certain aging effects (crevice and pitting corrosion) not addressed by the GALL are also managed by the Chemistry Program. Additionally, the attributes of the Chemistry Program meet the intent of the corresponding GALL Chapter XI program (XI.M2) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b RC Upper Core Plate Fuel Alignment Pins

1, 3 Stainless Steel (Type 316)

Borated Water

Void Swelling Changes in Dimensions

Reactor Vessel Internals Inspection

See Note A-RC1b-d.

IV.B2.1-j, IV.B2.1.6

T.1-11 Yes, Plant Specific No Material is SS, GALL list both SS and Ni alloy. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program attributes. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1b IC Instrumentation, Incore Thermocouples Seal

4, 7 Stainless Steel (Type 304)

Reactor Building

Stress Relaxation, Wear

Loss of Mechanical Closure Integrity

In-Service Inspection (ISI) Plan

See Note A-RC1b-f.

N/A N.1-04 N/A N/A Incore Thermocouple seals are not listed in GALL. The material/enviroment/aging effect combination for this sub-component is not addressed for any GALL item in chapters IV, V, VII, or VIII. Refer to TR00160-020 for a discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

RC1b IC Incore Neutron Detector (Flux) Thimbles (XD0004-IC) - Bottom Mounted Instrumentation

4, 7 Stainless Steel (Type 304)

Ventilation * None Identified None Identified None Required See Note A-RC1b-f.

N/A N.1-01 N/A N/A The sub-component AMR result is for a material and environment combination that is not addressed in GALL Chapters IV, V, VII and VIII (GALL item V.C.1-b addresses the material and includes the environment, along with the internal environment, however, the aging effects for this GALL item are focused on the internal environment effects). Also, for VCSNS, no aging effects were determined to

Page 348: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 348 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

require management during the period of extended operation as detailed in the applicable note.

RC1b RC Lower Support Column Bolts

1, 4, 5 Stainless Steel (Type 316)

Borated Water

Stress Relaxation Loss of Preload Reactor Vessel Internals Inspection

See Note A-RC1b-g.

IV.B2.5-h, IV.B2.5.5

T.1-48 No Partial Material is SS, GALL lists both SS and Ni alloy. Except as noted, the sub-component AMR results are consistenet with the specified GALL item with respect to material, environment and aging effect requiring management. Whereas the GALL item specifies the ASME Section XI ISI (XI.M1) and Loose Parts Monitoring (XI.M14), VCSNS credits the Reactor Vessel Internals Inspection. The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of susceptible RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of a corresponding GALL Chapter XI program (XI.M16) attributes, as clarified . However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of GALL program XI.M16.

RC1b RC Lower Support Column Bolts

1, 4, 5 Stainless Steel (Type 316)

Borated Water

Irradiation Embrittlement

Reduction of Fracture Toughness

Reactor Vessel Internals Inspection

See Note A-RC1b-e.

IV.B2.5-g, IV.B2.5.5

T.1-43 No Partial The Reactor Vessel Internals Inspection is a new activity/program, supplementing ISI, to address Irradiation Embrittlement, IASCC, Stress Relaxation, Void Swelling, and Wear of stainless steel RV Internals (EPRI MRP ITG). This program includes visual and volumetric examinations. The attributes of the Reactor Vessel Internals Inspection meet the intent of the corresponding GALL Chapter XI program (XI.M16) attributes, as clarified. However, the program is not completely developed and it is unlikely it will include the 0.0005 in resolution shown in XI.M16. For this reason, all items covered by the Reactor Vessel Internals Inspection are at best a "Partial Match". Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent

Page 349: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 349 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL program. EF EF Pipe and Fittings PB Carbon Steel Underground Crevice Corrosion,

Galvanic Corrosion, General Corrosion, Microbiologically Induced Corrosion (MIC), Pitting Corrosion

Loss of Material Buried Piping and Tanks Inspection

See Note A-EF-y

VIII.G.1-e, VIII.G.1.2

T.4-12 Yes, detection of aging effects and operating experience are to be further evaluated.

Partial VIII.G.1-e addresses Auxiliary Feedwater System components. The material, environment, aging effects requiring management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effects and credited activity. However, the attributes of the credited activity are not fully consistent with the corresponding program attributes as described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Traps (Body Only) PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-MS-ii, See Note A-MS-j

VIII.B1.1-a, VIII.B1.1.2

T.4-07 No Yes VIII.B1.1-a addresses Main Steam System piping and fittings. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

GS GS Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-GS-a, See Note A-GS-b

VIII.B1.2-a, VIII.B1.2.1

T.4-07 No Yes VIII.B1.2-a addresses Main Steam System valve bodies. The material, environment, aging effects requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Certain aging effects not addressed by the GALL item are also managed by the credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent

Page 350: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 350 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

of the pertinent GALL program. GS GS Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for

Mechanical Components

See Note A-GS-c, See Note A-GS-d

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

GS GS Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-GS-c, See Note A-GS-d

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

GS GS Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-GS-c, See Note A-GS-d

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

MS MS Traps (Body Only) PB Alloy Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-MS-k, See Note A-MS-l

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel/alloy steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for

Page 351: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 351 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS MS Traps (Body Only) PB Alloy Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-MS-k, See Note A-MS-l

VIII.H.1-a, VIII.H.1.1

T.4-13 No Yes VIII.H.1-a addresses external surfaces of carbon steel/alloy steel components. The material, environment, aging effect requiring management and credited activity for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited activity. Additionally, the attributes of the credited activity meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

FS FS Pipe and Fittings PB Galvanized Steel

Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-FS-o, See Note A-FS-p

VII.I.1-b, VII.I.1.1

T.3-05 Yes, plant specific No VII.I.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

IA IA Tube & Tube Fittings PB Copper Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-IA-k See Note A-IA-p

N/A N.3-09 N/A N/A Component/Component type has a unique material/environment combination that is not addressed for any item in GALL Chapters IV, V, VII or VIII and the AMR results for this component/component type are therefore, specific to VCSNS. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

AH AH Cooling Coils (XAA-1A/B, -2A/B-AH), RCBUs - Headers

PB Copper Reactor Building

Galvanic Corrosion Loss of Material Inspections for Mechanical Components

See Note A-AH-c

VII.F1.2-a, VII.F1.2.1

T.3-05 Yes, plant specific No VII.F1.2-a addresses Control Room Area Ventilation System components. VCSNS determined that loss of material due to crevice and pitting corrosion are not aging effects requiring management for this component/component type. The component/component type AMR results are consistent with the identified GALL item in material and environment, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific

Page 352: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 352 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activity in effectively managing aging during the period of extended operation.

RC RC Drip Pan - RCP Oil Collection

FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Drip Pan - RCP Oil Collection

FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-b, VII.G.7.2

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Flame Arresters (XPS5021A/B/C-RC) - RCP Oil Collection

FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-b, VII.G.7.2

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Flame Arresters (XPS5021A/B/C-RC) - RCP Oil Collection

FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Flexible Hose - RCP Oil Collection

PB Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-b, VII.G.7.2

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Flexible Hose - RCP Oil PB Stainless Steel Reactor None Identified None Identified None Required TR00160-010, V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does

Page 353: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 353 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Collection Building Attachment IX not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Orifices PB, TH Stainless Steel Sheltered None Identified None Identified None Required See Note A-RC-e

V.C.1-b N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Orifices PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RC-b, See Note A-RC-c

IV.C2.1-c N.1-05, N.1-06

No Partial IV.C2.1-c addresses Reactor Coolant System piping and fittings. VCSNS found that cracking due to fatigue and cyclic loading are not aging effects for orifices and that the ISI Program identified in the GALL for this item is not applicable for these aging effects. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material and environment. Certain aging effects not addressed by the GALL item are also managed by the credited program. The attributes of the credited program meet the intent of a GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC RC Orifices PB, TH Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 354: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 354 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RC RC Pipe and Fittings PB Stainless Steel Sheltered Microbiologically Induced Corrosion (MIC)

Loss of Material Maintenance Rule Structures Program

See Note A-RC-e

V.C.1-b, V.C.1.2

N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. VCSNS found that loss of material due to crevice and pitting corrosion are not aging effects for stainless steel exposed to ambient air. The identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC RC Pipe and Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Pipe and Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RC-b, See Note A-RC-c

IV.C2.1-c N.1-05, N.1-06

No Partial IV.C2.1-c addresses Reactor Coolant System piping and fittings. VCSNS found that cracking due to fatigue and cyclic loading are not aging effects for this component and that the ISI Program identified in the GALL for this item is not applicable for these aging effects. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material and environment. Certain aging effects not addressed by the GALL item are also managed by the credited program. The attributes of the credited program meet the intent of a GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC RC Pipe - RCP Oil Collection PB, FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-b, VII.G.7.2

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

Page 355: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 355 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RC RC Pipe - RCP Oil Collection PB, FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Tanks (XTK0130A/B/C) - RCP Oil Collection Drain Tank

FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-a, VII.G.7.1

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Tanks (XTK0130A/B/C) - RCP Oil Collection Drain Tank

FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK1) - RCP Oil Collection Cooler Enclosure)

FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK1) - RCP Oil Collection Cooler Enclosure)

FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-a, VII.G.7.1

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK2) - RCP Oil Collection Lift Enclosure

FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL

Page 356: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 356 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK2) - RCP Oil Collection Lift Enclosure

FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-a, VII.G.7.1

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK3) - RCP Oil Collection Fill & Drain Enclosure

FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-a, VII.G.7.1

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK3) - RCP Oil Collection Fill & Drain Enclosure

FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK4) - RCP Oil Collection Upper Alarm & Gauge Enclosure

FP Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-a, VII.G.7.1

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-a addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Tanks (XTK3000A/B/C-TK4) - RCP Oil Collection Upper Alarm & Gauge Enclosure

FP Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of

Page 357: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 357 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation as detailed in the applicable note.

RC RC Tube & Tube Fittings PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Tube & Tube Fittings PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RC-e

V.C.1-b N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Tube & Tube Fittings PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RC-b, See Note A-RC-c

IV.C2.2-f, IV.C2.2.6

N.1-05, N.1-06

No Partial IV.C2.2-f addresses piping and fittings for systems connected to the Reactor Coolant System. VCSNS found that cracking due to fatigue is not an aging effect for this component and that the ISI Program identified in the GALL for this item is not applicable for this aging effect. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material, and environment. Certain aging effects not addressed by the GALL item are also managed by the credited program. The attributes of the credited program meet the intent of a GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC RC Tube & Tube Fittings PB Stainless Steel Treated Water

None Identified None Identified None Required See Note A-RC-d

V.C.1-b N.1-12 Yes, plant specific No V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended

Page 358: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 358 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

operation as detailed in the applicable note. RC RC Valves (Body Only) PB Stainless Steel Borated

Water Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Note A-RC-b, See Note A-RC-c

IV.C2.4-b, IV.C2.4.1

N.1-05, N.1-06

No Partial IV.C2.4-b addresses Reactor Coolant System valve bodies. VCSNS found that cracking due to fatigue is not an aging effect for this component and that the ISI Program identified in the GALL for this item is not applicable for this aging effect. Except as noted, the AMR results for this component/component type are consistent with the identified GALL item which has a similar material and environment. Certain aging effects not addressed by the GALL item are also managed by the credited program. The attributes of the credited program meet the intent of a GALL Chapter XI program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC RC Valves (Body Only) PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

V.C.1-b N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Valves (Body Only) PB Stainless Steel Sheltered None Identified None Identified None Required See Note A-RC-e

V.C.1-b N.1-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does not address the external surface of stainless steel components. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Valves (Body Only) - RCP Oil Collection

PB Stainless Steel Oil None Identified None Identified None Required See Note A-RC-a

VII.G.7-b, VII.G.7.2

T.3-06 Yes, detection of aging effects is to be evaluated

No VII.G.7-b addresses Reactor Coolant Pump Oil Collection System components. The component/component type AMR results are consistent with the identified GALL item in environment. However, for VCSNS, no aging effects were determined to require management during the period of extended opeation as detailed in the applicable note.

RC RC Valves (Body Only) - PB Stainless Steel Reactor None Identified None Identified None Required TR00160-010, V.C.1-b N.3-01 Yes, plant specific No GALL Section IV.C2, for RCS piping, does

Page 359: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 359 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RCP Oil Collection Building Attachment IX not address the external surface of stainless steel components. Neither does GALL Section VII.G.7, RCP oil collection. However, GALL item V.C.1-b addresses the external surface of stainless steel containment Isolation components. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1a IC XD0003-IC, XD0005-IC - Tube & Fittings / Incore Neutron Detector Conduits (BMI guide tubes)

PB, Support

Stainless Steel Ventilation * None Identified None Identified None Required See Note A-RC1a-ii.

N/A N.1-01 N/A N/A The sub-component AMR results address a material and environment combination that cannot be readily connected to a GALL Chaper IV, V, VII, or VIII item. GALL item IV.A2.2-e addressed a stainless steel / ambient air combination. However, that GALL item addresses cracking of bolt material and is not applicable to the BMI guide tubes & fittings. Also, for VCSNS BMI guide tubes, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1a IC XD0003-IC, XD0005-IC - Tube & Fittings / Incore Neutron Detector Conduits (BMI guide tubes)

PB, Support

Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1a-a and A-RC1a-b.

IV.C2.1-g, IV.C2.1.5

N.1-07, N.1-11

Yes, parameters monitored/inspected and detection of aging effects are to be evaluated

Partial IV.C2.1-g addresses RCS piping and fittings (< NPS 4) and crack initiation/growth and is the closest match with regards to material, environment, and aging effect requiring management to the Bottom Mounted Instrumentation (BMI) guide tubes AMR results. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which have a similar material, environment, aging effect/mechanism requiring management. In addition to cracking, certain aging effects (loss of material due to crevice and/or pitting corrosion) not addressed by the GALL item are also managed by the credited program. However, VCSNS determined the Chemistry program to be sufficient to manage the specified effects in this particular instance, since thermal and mechanical loading on the BMI guides tubes would be much less than that on other small bore pipe, whereas the GALL item specifies a combination of ISI and Chemistry. Additionally, the attributes of the credited program meet the intent of a GALL Chapter XI program (XI.M2),. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity ineffectively managing aging during the period of

Page 360: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 360 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation and in meeting the intent of a pertinent GALL program.

RC1a RC XRD0008 - CRDM Latch Housing

PB Stainless Steel (CASS)

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX; WCAP-14581. See Note A-RC1a-j.

N/A N.1-01 N/A N/A The sub-component AMR results address a material and environment combination that cannot be readily connected to a GALL Chaper IV, V, VII, or VIII item. GALL item IV.A2.2-e addressed a stainless steel / ambient air combination. However, that GALL item addresses cracking of flange bolt material and is not applicable to the VCSNS CRDM housing. Also, for VCSNS CRDM housings, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1a RC XRD0008 - CRDM Latch Housing

PB Stainless Steel (CASS)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-a, See Note A-RC1a-b

IV.A2.2-b, IV.A2.2.2

T.1-36, N.1-07

No Yes GALL item IV.A2.2-b addresses stress corrosion cracking of the CRDM pressure housing. The material, environment, aging effect requiring management, and credited programs for this component are consistent with the identified GALL item, as clarified. Certain aging mechanisms (crevice and pitting corrosion) not addressed by the GALL item are also managed by one of the credited programs (Chemistry). The Chemistry program is the primary program credited for aging management, whereas the ISI Plan supplements Chemistry control for this sub-component, with regard to cracking. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the programs in meeting the intent of the pertinent GALL programs ( XI.M2 and XI.M1 respectively).

RC1a RC XRD0008 - CRDM Rod Travel Housing

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-a, See Note A-RC1a-b

IV.A2.2-b, IV.A2.2.2

T.1-36, N.1-07

No Yes GALL item IV.A2.2-b addresses stress corrosion cracking of the CRDM pressure housing. The material, environment, aging effect requiring management, and credited programs for this component are consistent with the identified GALL item, as clarified. Certain aging mechanisms (crevice and pitting corrosion) not addressed by the GALL item are also managed by one of the credited programs (Chemistry). The Chemistry program is the primary program credited for aging management, whereas the ISI Plan supplements Chemistry control for this sub-component, with regard to cracking. Additionally, the attributes of the credited

Page 361: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 361 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

programs meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the programs in meeting the intent of the pertinent GALL programs ( XI.M2 and XI.M1 respectively).

RC1a RC XRD0008 - CRDM Rod Travel Housing

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX; WCAP-14581. See Note A-RC1a-j

N/A N.1-01 N/A N/A The sub-component AMR results address a material and environment combination that cannot be readily connected to a GALL Chaper IV, V, VII, or VIII item. GALL item IV.A2.2-e addressed a stainless steel / ambient air combination. However, that GALL item addresses cracking of flange bolt material and is not applicable to the VCSNS CRDM housing. Also, for VCSNS CRDM housings, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1a RC XRD0008 - CRDM Top Top Cap/Vent Plug

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX; WCAP-14581

N/A N.1-01 N/A N/A The sub-component AMR results address a material and environment combination that cannot be readily connected to a GALL Chaper IV, V, VII, or VIII item. GALL item IV.A2.2-e addressed a stainless steel / ambient air combination. However, that GALL item addresses cracking of flange bolt material and is not applicable to the VCSNS CRDM cap. Also, for VCSNS CRDM caps, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1a RC XRD0008 - CRDM Top Top Cap/Vent Plug

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-a, See Note A-RC1a-b

IV.A2.2-b, IV.A2.2.2

T.1-36, N.1-07

No Yes GALL item IV.A2.2-b addresses stress corrosion cracking of the CRDM pressure housing. The material, environment, aging effect requiring management, and credited programs for this component are consistent with the identified GALL item, as clarified. Certain aging mechanisms (crevice and pitting corrosion) not addressed by the GALL item are also managed by one of the credited programs (Chemistry). The Chemistry program is the primary program credited for aging management, whereas the ISI Plan supplements Chemistry control for this sub-component, with regard to cracking. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the programs in meeting the intent of the

Page 362: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 362 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

pertinent GALL programs ( XI.M2 and XI.M1 respectively).

RC1a RC XRE0001 - RV Bottom Head Dome

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.1-a, IV.A2.1.1

T.1-38 No Yes GALL Item IV.A2.1-a addresses boric acid corrosion of the closure head dome (IV.A2.1.1). The material, environment, aging effect requiring management, and the credited program for this component (bottom head dome) are consistent with the identified GALL item. The bottom head dome (IV.A2.5.4) is not addressed for boric acid corrosion explicitly in the GALL. The attributes of the credited activity meets the intent of the corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Bottom Head Dome (Cladding)

PB Alloy Steel clad w/ Austenitic Stainless Steel

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-g, See Note A-RC1a-h

IV.A2.2-b T.1-36, N.1-07

No Partial GALL Item IV.A2.5-d addresses cumulative fatigue and includes the bottom head (IV.A2.5.4), the only location in the GALL for the bottom head. The sub-component AMR results are consistent with that GALL item in material and envirionment. However, cumulative fatigue is addressed in technical reports TR00140-001 and TR00140-002 and has not been explicitly identified as an aging effect, although flaw growth at welds is an aging mechanism and is related to service (cyclic) loading. However, the material, environment, aging effect requiring management and credited aging management programs are consistent with GALL item IV.A2.2-b, as clarified. GALL item IV.A2.2-b addresses SCC of the stainless steel CRDM housing. The material for this GALL item is consistent with the cladding material for the sub-component and both are susceptible to SCC. Additional mechanisms not addressed in the GALL (crevice and pitting corrosion, and flaw growth at welds) are also managed at VCSNS. Additionally, the attributes of the credited programs, as applied to Class 1 components meet the intent of corresponding GALL program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the corresponding GALL program (XI.M1 and XI.M2) attributes.

Page 363: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 363 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RC1a RC XRE0001 - RV Bottom Head Penetration Tubes

PB Nickel-Based Alloy

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan; Alloy 600 Aging Management Program

See Note A-RC1a-c, See Note A-RC1a-d

IV.A2.7-a, IV.A2.7.1

T.1-12, N.1-07

Yes, plant specific No GALL item IV.A2.7-a addresses PWSCC of RV bottom head penetration tubes. The material, environment, aging effects requiring management, and credited programs for this sub-component AMR result are consistent with the identified GALL item. However, additional aging effects (crevice corrosion, pitting corrosion, and SCC) were identified and are managed for VCSNS. One of these aging mechanisms (SCC) and the corresponding credited aging management programs are consistent with another GALL Chapter IV item, IV.A2.2-b, for stainless steel in the same environment. These aging mechanisms were conservatively considered to also be applicable to nickel-based alloys. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (X1.M2, and XI.M1 respectively ) attributes. Also, even though the GALL item (IV.A2.7-a) recommends plant specific program evaluation. The attributes of the Alloy 600 Aging Management Program meet the intent of GALL program XI.M11 (Nickel-Alloy Nozzles and Penetrations) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in meeting the intent of the pertinent GALL programs.

RC1a RC XRE0001 - RV Bottom Head Penetration Tubes

PB Nickel-Based Alloy

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX; WCAP-14581

N/A N.1-02 N/A N/A The sub-component AMR results are for a material and environment combination that is not addressed in the GALL Report, especially in Chapter IV. Also, no aging effects were determined to require management during the period of extended operation as per the applicable note.

RC1a RC XRE0001 - RV Closure Head & Vessel Flanges

PB Alloy Steel Reactor Building

Wear Loss of Material In-Service Inspection (ISI) Plan

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.5-f, IV.A2.5.3

T.1-40 No Yes GALL item IV.A2.5-f addresses wear of the vessel flange (IV.A2.5.3). The material, environment, aging effects requiring management, and the credited programs for this sub-component are consistent with the identified GALL item. Also, the attributes of the credited program meets the intent of the corresponding GALL Chapter XI program (XI.M1) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended opeation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Closure Head & Vessel Flanges

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical

Loss of Material Boric Acid Corrosion

See Note A-RC1a-e, See

IV.A2.5-e, IV.A2.5.3

T.1-38 No Yes GALL item IV.A2.5-e addresses boric acid corrosion of the vessel flange( IV.A2.5.3)

Page 364: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 364 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Attack) Surveillances Note A-RC1a-f respectively. The material, environment, aging effects requiring management, and the credited programs for this sub-component are consistent with the identified GALL item. Also, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended opeation and in meeting the intent of the pertinent GALL programs.

RC1a RC XRE0001 - RV Closure Head & Vessel Flanges (Cladding)

PB Alloy Steel clad w/ Austenitic Stainless Steel

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-g, See Note A-RC1a-h

IV.A2.2-b T.1-36, N.1-07

No Partial GALL Item IV.A2.5-d addresses cumulative fatigue and includes the vessel flange (IV.A2.5.3), the only location in the GALL for the vessel flange and exposure to chemically treated borated water. The sub-component AMR results are consistent with that GALL item in material and envirionment. However, cumulative fatigue is addressed in technical reports TR00140-001 and TR00140-002 and has not been explicitly identified as an aging effect, although flaw growth at welds is an aging mechanism and is related to service (cyclic) loading. However, the material, environment, aging effect requiring management and credited aging management programs are consistent with GALL item IV.A2.2-b, as clarified. GALL item IV.A2.2-b addresses SCC of the stainless steel CRDM housing. The material for this GALL item is consistent with the cladding material for the sub-component and both are susceptible to SCC. Additional mechanisms not addressed in the GALL (crevice and pitting corrosion, and flaw growth at welds) are also managed at VCSNS. Additionally, the attributes of the credited programs, as applied to Class 1 components meet the intent of corresponding GALL program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the corresponding GALL program (XI.M1 and XI.M2) attributes.

RC1a RC XRE0001 - RV Closure Head Dome & Lifting Lugs

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.1-a, IV.A2.1.1

T.1-38 No Yes GALL Item IV.A2.1-a addresses boric acid corrosion of the closure head dome (IV.A2.1.1). The material, environment, aging effect requiring management, and the credited program for the sub-component AMR results are consistent with the identified

Page 365: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 365 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL item. The attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Closure Head Dome (Cladding)

PB Alloy Steel clad w/ Austenitic Stainless Steel

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-g, See Note A-RC1a-h

IV.A2.2-b T.1-36, N.1-07

No Partial GALL Item IV.A2.1-b addresses cumulative fatigue of the closure dome (IV.A2.1.1) with exposure to borated water, the only GALL location which addresses the sub-component/material/environment combination. The sub-component AMR results are consistent with that GALL item in material and envirionment. However, the material, environment, aging effect requiring management and credited aging management programs are consistent with GALL item IV.A2.2-b, as clarified. GALL item IV.A2.2-b addresses SCC of the stainless steel CRDM housing. The material for this GALL item is consistent with the cladding material for the sub-component and both are susceptible to SCC. Additional mechanisms not addressed in the GALL (crevice and pitting corrosion, and flaw growth at welds) are also managed at VCSNS. Additionally, the attributes of the credited programs, as applied to Class 1 components meet the intent of corresponding GALL program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the corresponding GALL program (XI.M1 and XI.M2) attributes.

RC1a RC XRE0001 - RV Closure Head Penetration Safe Ends (CR, Instrument , Vent Pipe)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-a, See Note A-RC1a-b

IV.A2.2-b, IV.A2.2.2

T.1-36, N.1-07

No Yes GALL item IV.A2.2-b address stress corrosion cracking of the CRDM pressure housing. The material, environment, aging effect requiring management, and credited programs for this component are consistent with the identified GALL item, as clarified. Certain aging mechanisms (crevice and pitting corrosion) not addressed by the GALL item are also managed by one of the credited programs (Chemistry). The Chemistry program is the primary program credited for aging management, whereas the ISI Plan supplements Chemistry control for this sub-component, with regard to cracking.

Page 366: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 366 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the programs in meeting the intent of the pertinent GALL programs ( XI.M2 and XI.M1 respectively).

RC1a RC XRE0001 - RV Closure Head Penetration Safe Ends (CR, Instrument , Vent Pipe)

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX; WCAP-14581

N/A N.1-01 N/A N/A The sub-component AMR results address a material and environment combination that cannot be readily connected to a GALL Chaper IV, V, VII, or VIII item. GALL item IV.A2.2-e addressed a stainless steel / ambient air combination. However, that GALL item addresses cracking of flange bolt material (implies SCC of bolting due to the presence boric acid) and is not applicable to the VCSNS safe ends. Also, for VCSNS RV safe ends, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1a RC XRE0001 - RV Closure Head Penetration Tubes (CR, Instrument , Vent Pipe)

PB Nickel-Based Alloy

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan; Alloy 600 Aging Management Program

See Note A-RC1a-c, See Note A-RC1a-d

IV.A2.2-a, IV.A2.2.1

T.1-35, N.1-07, N.1-11B

No Partial GALL item IV.A2.2-a addresses PWSCC of control rod drive head penetration nozzles. The material, environment, aging effect requiring management, and credited programs for this sub-component AMR result are consistent with the identified GALL item with regard to PWSCC. However, additional aging effects (crevice corrosion, pitting corrosion, and SCC) were identified and are managed for VCSNS. One of these aging mechanisms (SCC) and the corresponding credited aging management programs are consistent with another GALL Chapter IV item, IV.A2.2-b, for stainless steel in the same environment. These aging mechanisms were conservatively considered to also be applicable to nickel-based alloys. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (X1.M2, and XI.M1 respectively ) attributes. Also, the attributes of the Alloy 600 Aging Management Program meet the intent of GALL program XI.M11 (Nickel-Alloy Nozzles and Penetrations) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in meeting the intent of the pertinent GALL programs.

RC1a RC XRE0001 - RV Closure Head Penetration Tubes (CR, Instrument , Vent

PB Nickel-Based Alloy

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX; WCAP-14581

N/A N.1-02 N/A N/A The sub-component AMR results are for a material and environment combination that is not addressed in the GALL Report, especially

Page 367: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 367 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Pipe) in Chapter IV. Also, no aging effects were determined to require management during the period of extended operation as per the applicable note.

RC1a RC XRE0001 - RV Closure Stud Assembly (including nuts & washers)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.1-a, IV.A2.1.3

T.1-38 No Yes The material, environment, aging effects requiring management, and the credited activity for this sub-component are consistent with the identified GALL item which have the same material, environment, aging effect, and credited program. The attributes of the credited actvity meet the intent of the corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Closure Stud Assembly (including nuts & washers)

PB Alloy Steel Reactor Building

Stress Relaxation, Stress Corrosion Cracking (SCC), Wear

Loss of Mechanical Closure Integrity

Reactor Head Closure Studs Program

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.1-c, IV.A2.1-d, IV.A2.1.3

T.1-22, T.1-47

No Yes GALL items IV.A2.1-c and IV.A2.1-d address stress corrosion cracking and wear respectively of the closure stud assembly (IV.A2.1.3). The material, environment, aging effect requiring management, and credited aging management program for this sub-component are consistent with the identified GALL item, with the clarification that a loss of closure integrity rather than loss of material is the effect requiring management and the additional mechanism of stress relaxation being managed. Also, the attributes of the credited program are consistent wit h the corresponding program (XI.M3) attributes described in GALL Chapter XI. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended opeation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Core Support Pads (Clevises/Keyways)

PB Nickel-Based Alloy

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds; Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Note A-RC1a-c, See Note A-RC1a-d

IV.A2.6-a T.1-12, N.1-07

Yes, plant specific No GALL item IV.A2.6-a addresses PWSCC of core support pads. The material, environment, aging effect requiring management, and credited program for this sub-component AMR result are consistent with the identified GALL item with regard to PWSCC. However, additional aging effects (crevice corrosion, pitting corrosion, SCC, and flaw growth at welds) were identified and are managed for VCSNS. One of these aging mechanisms (SCC) and the corresponding credited aging management programs are consistent with another GALL Chapter IV item, IV.A2.2-b, for stainless steel in the

Page 368: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 368 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

same environment. These aging mechanisms were conservatively considered to also be applicable to nickel-based alloys. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (X1.M2, and XI.M1 respectively ) attributes. Also, even though the GALL item (IV.A2.6-a) recommends plant specific program evaluation, the credited program (ISI Plan) meets the intent of a corresponding GALL program (XI.M1), and provides adequate management of PWSCC as detailed in the applicable Note. Refer to TR00160-020 for a detailed discussion of the attributes of these programs effectively managing aging during the period of extended operation.

RC1a RC XRE0001 - RV Inlet & Outlet Nozzle Safe Ends

PB Nickel-Based Alloy

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds, Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan; Alloy 600 Aging Management Program

See Note A-RC1a-c, See Note A-RC1a-d

IV.A2.4-b, IV.A2.4.1, IV.A2.4.2

T.1-36, N.1-07

No Yes The material, environment, aging effects requiring management, and credited programs for this sub-component (alloy 600 weld metal) are consistent with the identified GALL item. However, additional aging effects/mechanisms (crevice & pitting corrosion and flaw growth at welds) were identified and are managed for VCSNS. These aging mechanisms were conservatively considered to also be applicable to nickel-based alloys. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (X1.M2, XI.M1, and XI.M11 respectively ) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these programs/activities in meeting the intent of the pertinent GALL programs.

RC1a RC XRE0001 - RV Inlet & Outlet Nozzle Safe Ends

PB Nickel-Based Alloy

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX; WCAP-14581

N/A N.1-02 N/A N/A The sub-component AMR results are for a material and environment combination that is not addressed in the GALL Report, especially in Chapter IV. Also, no aging effects were determined to require management during the period of extended operation as per the applicable note.

RC1a RC XRE0001 - RV Inlet & Outlet Nozzles (including cladding)

PB Alloy Steel clad w/ Austenitic Stainless Steel

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds; Radiation Embrittlement

Loss of Material; Cracking; Reduction of Fracture Toughness

Chemistry Program; In-Service Inspection (ISI) Plan; Reactor Vessel Surveillance Program

See Note A-RC1a-g, See Note A-RC1a-h

IV.A2.3-b, IV.A2.3.1, IV.A2.3.2

T.1-05, N.1-07

Yes, plant specific No GALL Item IV.A2.3-b addresses neutron embrittlement of the inlet/outlet nozzles (IV.A2.3.1 and IV.A2.3.2). The sub-component AMR results are consistent with the identified GALL item in material, envirionment, and aging effect requiring management, as clarified. Other aging mechanisms requiring management (crevice & pitting corrosion, SCC, and flaw growth at welds) that are not addressed in GALL for

Page 369: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 369 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

this item are applicable to this sub-component. Also, the material (cladding), environment, aging effect requiring management (SCC) and credited aging management programs (Chemistry Program and ISI Plan) for these other aging effects are consistent with GALL item IV.A2.2-b, which addresses SCC of the stainless steel CRDM housing. Furthermore, the attributes of these programs, as applied to Class 1 components, are consistent with the attributes of corresponding GALL programs (XI.M2 and XI.M1 respectively). Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program. Even though GALL item IV.A2.3-b recommends plant specific evaluation, the item specifies a GALL chapter XI program (XI.M31) for management. The upper shell and nozzles are not normally considered to be susceptible to radiation embrittlement due to their physical distance from the active fuel assemblies. However, the Reactor Vessel Surveillance program will manage radiation embrittlement in the upper shell (nozzle) course through addressing the most limiting sub-components with respect to exposure to the greatest fluence (i.e. those sub-components adjacent to active fuel assemblies) as well as confirming that fluence levels, postulated to occur in and around the nozzle course during the period of extended operation, will not reach levels sufficient to cause embrittlement. However, as described in TR00160-020, the attributes of the Reactor Vessel Surveillance Program are not fully consistent with the attributes of the corresponding GALL program (XI.M31). Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

RC1a RC XRE0001 - RV Inlet & Outlet Nozzles (including Nozzle Support Pads)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.5-e, IV.A2.5.3

T.1-38 No Yes The material, environment, aging effects requiring management, and the credited activity for this sub-component are consistent with the identified GALL item which have the same material, environment, aging effect, and credited program. The attributes of the credited actvity meet the intent of the

Page 370: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 370 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Shell, Core Region

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.5-e T.1-38 No Yes The material, environment, aging effects requiring management, and the credited activity for this sub-component are consistent with the identified GALL item which have the same material, environment, aging effect, and credited program. The attributes of the credited actvity meet the intent of the corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Shell, Core Region - Intermediate and Lower Shell Plates (including cladding)

PB Alloy Steel clad w/ Austenitic Stainless Steel

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds; Radiation Embrittlement

Loss of Material; Cracking; Reduction of Fracture Toughness

Chemistry Program; In-Service Inspection (ISI) Plan; Reactor Vessel Surveillance Program

See Note A-RC1a-g, See Note A-RC1a-h

IV.A2.5-c, IV.A2.5.2

T.1-05, N.1-07

Yes, plant specific No GALL Item IV.A2.5-c addresses neutron irradiation embrittlement of the shell, including upper (IV.A2.5.1) and intermediate/lower (IV.A2.5.2). The sub-component AMR results are consistent with the identified GALL item in material, environment, aging effect requiring management and credited aging management program, as clarified. However, the GALL item specifies plant specific evaluation even though the specified program (XI.M31) is addressed in GALL chapter XI. Also, other aging effects requiring management (crevice & pitting corrosion, flaw growth at welds, and SCC) that are not addressed in GALL for this item are applicable to this sub-component. The material (cladding), environment, aging effect requiring management (SCC) and credited aging management programs for these other aging mechanisms are consistent with GALL item IV.A2.2-b, which addresses SCC of stainless steel in the same environment. Additionally, the attributes of the credited programs for management of SCC and flaw growth at welds (as well as crevice &/or pitting corrosion) are consistent with the attributes of the corresponding GALL programs Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation

Page 371: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 371 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

and in meeting the intent of the corresponding GALL program ( XI.M2 and XI.M1 respectively). Even though GALL item IV.A2.5-c recommends plant specific evaluation, the item specifies a GALL chapter XI program (XI.M31) for management. However, the attributes of the Reactor Vessel Surveillance Program are not fully consistent with the attributes of the corresponding GALL program (XI.M31), as described in TR00160-020. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation.

RC1a RC XRE0001 - RV Shell, Nozzle Course & Refueling Seal Ledge

PB Alloy Steel & Carbon Steel

Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.5-e T.1-38 No Yes The material, environment, aging effects requiring management, and the credited activity for this sub-component are consistent with the identified GALL item which have the same material, environment, aging effect, and credited program. The attributes of the credited actvity meet the intent of the corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1a RC XRE0001 - RV Shell, Upper Shell (Nozzle) Course (including cladding)

PB Alloy Steel clad w/ Austenitic Stainless Steel

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds; Radiation Embrittlement

Loss of Material; Cracking; Reduction of Fracture Toughness

Chemistry Program; In-Service Inspection (ISI) Plan; Reactor Vessel Surveillance Program

See Note A-RC1a-g, See Note A-RC1a-h

IV.A2.5-c, IV.A2.5.1

T.1-05, N.1-07

Yes, plant specific No GALL Item IV.A2.5-c addresses neutron irradiation embrittlement of the shell, including upper (IV.A2.5.1) and intermediate/lower (IV.A2.5.2). The sub-component AMR results are consistent with the identified GALL item in material, environment, aging effect requiring management and credited aging management program, as clarified. However, the GALL item specifies plant specific evaluation even though the specified program (XI.M31) is addressed in GALL chapter XI. Also, other aging effects requiring management (crevice & pitting corrosion, flaw growth at welds, and SCC) that are not addressed in GALL for this item are applicable to this sub-component. The material (cladding), environment, aging effect requiring management (SCC) and credited aging management programs for these other aging mechanisms are consistent with GALL item IV.A2.2-b, which addresses SCC of stainless steel in the same environment.

Page 372: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 372 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Additionally, the attributes of the credited programs for management of SCC and flaw growth at welds (as well as crevice &/or pitting corrosion) are consistent with the attributes of the corresponding GALL programs Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the corresponding GALL program ( XI.M2 and XI.M1 respectively). Even though GALL item IV.A2.5-c recommends plant specific evaluation, the item specifies a GALL chapter XI program (XI.M31) for management. The upper shell and nozzles are not normally considered to be susceptible to radiation embrittlement due to their physical distance from the active fuel assemblies. However, the Reactor Vessel Surveillance program will manage radiation embrittlement in the upper shell (nozzle) course through addressing the most limiting sub-components with respect to exposure to the greatest fluence (i.e. those sub-components adjacent to active fuel assemblies) as well as confirming that fluence levels, postulated to occur in and around the nozzle course during the period of extended operation, will not reach levels sufficient to cause embrittlement. However, the attributes of the Reactor Vessel Surveillance Program are not fully consistent with the attributes of the corresponding GALL program (XI.M31), s described in TR00160-020. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation.

RC1a RC XRE0001 - RV Ventilation Shroud Support Ring

PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-RC1a-e, See Note A-RC1a-f

IV.A2.5-e T.1-38 No Yes The material, environment, aging effects requiring management, and the credited activity for this sub-component are consistent with the identified GALL item which have the same material, environment, aging effect, and credited program. The attributes of the credited actvity meet the intent of the corresponding GALL Chapter XI program (XI.M10) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of these activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL

Page 373: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 373 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

program. RC1c RC Bolting Materials - Pipe

and Valves (<2" diameter)

PB Stainless Steel Reactor Building

Stress Relaxation, Stress Corrosion Cracking (SCC), Wear

Loss of Mechanical Closure Integrity

In-Service Inspection (ISI) Plan

See Note A-RC1c-e.

IV.C2.4-g, IV.C2.4.3

T.1-26 No Partial GALL recommends a bolting integrity program be established. The bolting integrity program (XI.M18) uses elements of ASME Section XI for detection of aging effects. The program credited for managing the effects of aging, the "Inservice Inspection Plan", meets only the portions of GALL Program XI.M18, "Bolting Integrity", that apply to Class 1 bolting of less than 2 inch diameter. Therefore, this is a partial match. Except as noted, the AMR results for this component type are consistent with the GALL items which have a similar material, environment, aging effect/mechanism and credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC1c RC Bolting Materials - Pipe and Valves (<2" diameter)

PB Alloy Steel Reactor Building

Stress Relaxation, Stress Corrosion Cracking (SCC), Wear

Loss of Mechanical Closure Integrity

In-Service Inspection (ISI) Plan

See Notes A-RC1c-c, A-RC1c-j.

IV.C2.4-g, IV.C2.4.3

T.1-26 No Partial GALL recommends a bolting integrity program be established. The bolting integrity program (XI.M18) uses elements of ASME Section XI for detection of aging effects. The program credited for managing the effects of aging, the "Inservice Inspection Plan", meets only the portions of GALL Program XI.M18, "Bolting Integrity", that apply to Class 1 bolting of less than 2 inch diameter. Therefore, this is a partial match. Except as noted, the AMR results for this component type are consistent with the GALL items which have a similar material, environment, aging effect/mechanism and credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC1c RC Bolting Materials - Pipe and Valves (<2" diameter)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1c-k, A-RC1c-j.

IV.C2.4-f, IV.C2.4.3

T.1-38 No Yes The material, environment, aging effects/mechanisms requiring management, and the credited program for this component type are consistent with the identified GALL item. The attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR000160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1c RC Elbows and Nozzles - Reactor Coolant Loop

PB CASS Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program; In-Service Inspection

See Notes A-RC1c-a, A-RC1c-b, A-

IV.C2.1-e, IV.C2.1.1, IV.C2.1.2

T.1-13, N.1-05

Yes, plant specific No The material, environment, aging effects/mechanisms requiring management, and the credited program for this component

Page 374: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 374 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC), Flaw Growth at Welds

(ISI) Plan RC1c-g, A-RC1c-l.

type are consistent with the identified GALL item, as clarified, except that the GALL specifies plant specific evaluation. Certain aging effects/mechanisms (crevice and pitting corrosion) not addressed by the GALL are also managed by the credited program (Chemistry). Additionally, although not identified in GALL for CASS piping specifically, cracking due to flaw growth at welds has been identified in the GALL for stainless steel or SS clad Reactor Coolant components and also requires management for the CASS elbows and nozzles at VCSNS. Consistent with the GALL for stainless steel, the ISI Plan is credited with management of cracking due to flaw growth at welds in these CASS sub-components. The attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (XI.M2 and XI.M1 respectively) attributes for the Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1c RC Elbows and Nozzles - Reactor Coolant Loop

PB CASS Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1c RC Orifices - Piping PB, TH Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1c RC Orifices - Piping PB, TH Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1c-a, A-RC1c-b, A-RC1c-g.

IV.C2.1-g, IV.C2.1.5

T.1-07, N.1-05

Yes, parameters monitored/inspected and detection of aging effects are to be evaluated.

Yes The material, environment, aging effects/mechanisms requiring management, and the credited programs for this component type are consistent with the identified GALL item, as clarified. The credited ISI Plan is focused on connections/junctures such as welds and thus on cracking due to flaw growth (referred to as Crack initiation and growth/cyclic and mechanical loading in GALL). The Chemistry program is credited for maintaining the conditions that could lead to SCC. In addition, certain aging effects not addressed by the GALL (crevice and pitting corrosion) for this component type are also

Page 375: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 375 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

managed by the same program. The attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (XI.M2 and XI.M1 respectively) attributes for the Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1c RC Pipe - Reactor Coolant System

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1c-a, A-RC1c-b, A-RC1c-g.

IV.C2.1-c, IV.C2.1.1, IV.C2.1.2, IV.C2.1.3

T.1-36, N.1-05

No Yes The material, environment, aging effects/mechanisms requiring management, and the credited programs for this component type are consistent with the identified GALL item, as clarified. The credited ISI Plan is focused on connections/junctures such as welds and thus on cracking due to flaw growth (referred to as Crack initiation and growth/cyclic and mechanical loading in GALL). The Chemistry program is credited for maintaining the conditions that could lead to SCC. In addition, certain aging effects not addressed by the GALL (crevice and pitting corrosion) for this component type are also managed by the same program. The attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (XI.M2 and XI.M1 respectively) attributes for the Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1c RC Pipe - Reactor Coolant System

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX. See Note A-RC1c-h.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1c RC Piping and Fittings - Connected systems

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1c RC Piping and Fittings - Connected systems

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1c-a, A-RC1c-b, A-RC1c-g.

IV.C2.2-f T.1-36, N.1-05

No Yes The material, environment, aging effects/mechanisms requiring management, and the credited programs for this component type are consistent with the identified GALL item, as clarified. Certain aging effects/mechanisms (crevice and pitting

Page 376: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 376 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corrosion) not addressed by the GALL are also managed by one of the credited programs (Chemistry). Additionally, although not identified in GALL for connected system piping specificaly, cracking due to flaw growth at welds (Cracking/cyclic and/or mechanical loading) has been identified in the GALL for stainless steel or SS clad Reactor Coolant components and also requires management for this component type at VCSNS. Consistent with the GALL for other stainless steel RCS components, the ISI Plan is credited with management of cracking due to flaw growth. The attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (XI.M2 and XI.M1 respectively) attributes for the Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1c RC Piping and Fittings - less than NPS 4"

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1c RC Piping and Fittings - less than NPS 4"

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program, In-Service Inspection (ISI) Plan, Small Bore Class 1 Piping Inspection

See Notes A-RC1c-a, A-RC1c-d, A-RC1c-g.

IV.C2.1-g, IV.C2.1.5

T.1-07, N.1-05

Yes, parameters monitored/inspected and detection of aging effects are to be evaluated

Yes The material, environment, aging effects/mechanisms requiring management, and the credited programs/activity for this component type are consistent with the identified GALL item, as clarified. The ISI Plan is focused on connections/junctures such as welds, and thus is credited for the management of cracking due to flaw growth (cracking /thermal and mechanical loading and thermal loading in GALL). This program is supplemented by the Small Bore Class 1 Piping Inspection activity to characterize the condition of the small bore piping (not normally inspected by ISI) and ensure that cracking has not occurred. The Chemistry program is credited for maintaining the conditions that could lead to SCC. In addition, certain aging effects not addressed by the GALL (crevice and pitting corrosion) for this component type are also managed by the same program. The attributes of the credited programs/activity meet the intent of the corresponding GALL Chapter XI program (XI.M1, XI.M2, XI.M32) attributes for the

Page 377: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 377 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs/activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1c RC Valves (Body Only) - Cast

PB CASS Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1c RC Valves (Body Only) - Cast

PB CASS Borated Water

Thermal Aging Reduction of Fracture Toughness

In-Service Inspection (ISI) Plan

See Notes A-RC1c-b, A-RC1c-g.

IV.C2.4-c, IV.C2.4.1

T.1-23 No Yes The material, environment, aging effects/mechanisms requiring management, and the credited program for this component type are consistent with the identified GALL item. The attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1c RC Valves (Body Only) - Cast

PB CASS Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1c-a, A-RC1c-b, A-RC1c-g, A-RC1c-l.

IV.C2.4-b, IV.C2.4.1

T.1-36, N.1-05

No Yes The material, environment, aging effects/mechanisms requiring management, and the credited program for this component type are consistent with the identified GALL item, as clarified, Certain aging effects/mechanisms (crevice and pitting corrosion) not addressed by the GALL are also managed by the credited program (Chemistry). Additionally, although not identified in GALL for CASS piping, cracking due to flaw growth at welds has been identified in the GALL for stainless steel or SS clad Reactor Coolant components and also requires management for this component type at VCSNS. Similar to the related non-CASS specific GALL items, the ISI Plan is credited with management. The attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (XI.M2 and XI.M1 respectively) attributes for the Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1c RC Valves (Body only) - Forged

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion;

Loss of Material; Cracking

Chemistry Program; In-

See Notes A-RC1c-a, A-

IV.C2.4-b, IV.C2.4.1

T.1-36, N.1-05

No Yes The material, environment, aging effects/mechanisms requiring management,

Page 378: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 378 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Stress Corrosion Cracking (SCC), Flaw Growth at Welds

Service Inspection (ISI) Plan

RC1c-b, A-RC1c-g.

and the credited programs for this component type are consistent with the identified GALL item, as clarified. The material of this component type is forged stainless steel, whereas the GALL only addresses CASS RCS valve bodies. Also, certain aging effects/mechanisms (crevice and pitting corrosion) not addressed by the GALL are also managed by one of the credited programs (Chemistry). Additionally, although not identified in GALL for valve bodies specifically, cracking due to flaw growth at welds has been identified in the GALL for stainless steel or SS clad Reactor Coolant components and also requires management for this component type (forged valve bodiers) at VCSNS. Similar to the related non-CASS specific GALL items, the ISI Plan is credited with management. The attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program (XI.M2 and XI.M1 respectively) attributes for the Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1c RC Valves (Body only) - Forged

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1d RC Bolting Materials - RCP Main Flange

PB Alloy Steel Reactor Building

Stress Relaxation, Stress Corrosion Cracking (SCC), Wear

Loss of Mechanical Closure Integrity

In-Service Inspection (ISI) Plan

See Notes A-RC1d-c, A-RC1d-k.

IV.C2.3-g, IV.C2.3.3

T.1-26 No Partial GALL recommends a bolting integrity program be established. The bolting integrity program (XI.M18) uses elements of ASME Section XI for detection of aging effects. The program credited for managing the effects of aging at VCSNS, the "In-Service Inspection (ISI) Plan", meets only the portions of GALL Program XI.M18, "Bolting Integrity", that apply to Class 1 bolting of less than 2 inch diameter. Therefore, this is a partial match. Except as noted, the AMR results for this component type are consistent with the GALL items which have a similar material, environment, aging effect/mechanism and credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

Page 379: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 379 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RC1d RC Bolting Materials - RCP Main Flange

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1d-e, A-RC1d-k.

IV.C2.3-f, IV.C2.3.3

T.1-38 No Yes The material, environment, aging effects/mechanisms requiring management, and the credited program for this component type are consistent with the identified GALL item. The attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1d RC Flange - RCP Thermal Barrier

PB Stainless Steel Reactor Building

None Identified None Identified None Required See Note A-RC1d-j. TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1d RC Flange - RCP Thermal Barrier

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1d-a, A-RC1d-g.

IV.C2.3-b, IV.C2.3.1

N.1-05, N.1-06

No Partial The material (stainless steel rather than CASS or cladding), environment, aging effects/mechanisms requiring management, and credited aging management program for this sub-component are consistent with the identified GALL item. However, the GALL item writeup is specific to CASS or stainless steel clad carbon steel for the RCP casing and no GALL item explicitly addresses the thermal barrier. In addition, certain aging effects/mechanisms not identified for this GALL item (crevice and pitting corrosion) require management at VCSNS and are managed by the same program. However, the credited program alone, rather than supplemented by Inservice Inspection as recommended by GALL, was determined to provide adequate management of the conditions that could result in the specified aging effects. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M2).

RC1d RC Flange - Thermal Barrier Piping

PB Stainless Steel Reactor Building

None Identified None Identified None Required See Note A-RC1d-j. TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1d RC Flange - Thermal Barrier Piping

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1d-a, A-RC1d-h.

VII.C2.2-a, VII.C2.1.1

T.3-15 No Partial The AMR results for this sub-component are partially consistent with a GALL item for closed-cycle cooling component which has a

Page 380: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 380 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC) similar material, environment (although at a lower temperature), and aging effects requiring management, as clarified. The higher temperatures associated with the operation of this sub-component make it susceptible to SCC (not identified for the listed GALL item) as described in the appropriate note. However, the GALL recommends a Closed-Cycle Cooling Water System AMP. The Chemistry Program credited for management at VCSNS does not match (is not fully consistent with) all of the criteria in Chapter XI.M21 of the GALL. Therefore, this is a partial match. Additionally, the attributes of the credited program meet the intent of a GALL Chapter XI program (XI.M2) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC1d RC Main Closure Flange - RCP

PB CASS Reactor Building

None Identified None Identified None Required See Note A-RC1d-j. TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1d RC Main Closure Flange - RCP

PB CASS Borated Water

Thermal Aging Reduction of Fracture Toughness

In-Service Inspection (ISI) Plan

See Notes A-RC1d-b, A-RC1d-g.

IV.C2.3-c, IV.C2.3.1

T.1-23 No Yes The material, environment, aging effects/mechanisms requiring management, and the credited program for this sub-component are consistent with the identified GALL item. The attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1d RC Main Closure Flange - RCP

PB CASS Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1d-a, A-RC1d-g.

IV.C2.3-b, IV.C2.3.1

T.1-36, N.1-07

No Yes The material, environment, aging effects/mechanisms requiring management, and credited program for this sub-component are consistent with the identified GALL item. The attributes of the credited program meet the intent of the corresponding GALL Chapter XI program (XI.M2) attributes for the Reactor Coolant System and material selection is not credited. Additionally, certain aging effects not addressed by the GALL (crevice and pitting corrosion)are also managed by the credited program for this sub-component. Refer to TR00160-020 for a detailed discussion of the attributes of this program in

Page 381: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 381 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1d RC RCP Thermal Barrier (including CVCS supply piping less than 4 inch)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at welds

Loss of Material; Cracking

Chemistry Program, In-Service Inspection (ISI) Plan, Small Bore Class 1 Piping Inspection

See Notes A-RC1d-a, A-RC1d-g. CVCS to thermal barrier (int/ext), CCW to thermal barrier (external).

IV.C2.2-h, IV.C2.2.8

T.1-07, N.1-05

Yes, parameters monitored/inspected and detection of aging effects are to be evaluated.

Yes The material, environment, aging effects/mechanisms requiring management, and the credited programs/activity for this component type are consistent with the identified GALL item, as clarified. The ISI Plan is focused on connections/junctures such as welds, and thus is credited for the management of cracking due to flaw growth (cracking/thermal and mechanical loading or thermal loading in GALL). This program is supplemented by the Small Bore Class 1 Piping Inspection activity to characterize the condition of the small bore piping from CVCS to the thermal barrier (not normally inspected by ISI) and ensure that cracking has not occurred. The Chemistry program is credited for maintaining the conditions that could lead to SCC. In addition, certain aging effects not addressed by the GALL (crevice and pitting corrosion) for this component type are also managed by the same program. The attributes of the credited programs/activity meet the intent of the corresponding GALL Chapter XI program (XI.M1, XI.M2, XI.M32) attributes for the Reactor Coolant System. Refer to TR00160-020 for a detailed discussion of the attributes of these programs/activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1d RC Piping/Tubing to RCP Thermal Barrier (less than NPS 4 inch)

PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1d-a, A-RC1d-h. CCW to thermal barrier (internal).

VII.C2.2-a, VII.C2.1.1

T.3-15 No Partial The AMR results for this sub-component are partially consistent with a GALL item for closed-cycle cooling component which has a similar material, environment (although at a lower temperature), and aging effects/mechanisms requiring management, as clarified. The higher temperatures associated with the operation of this sub-component make it susceptible to SCC (not identified for the listed GALL item) as described in the appropriate note. However, the GALL recommends a Closed-Cycle Cooling Water System AMP. The Chemistry Program credited for management at VCSNS does not match (is not fully consistent with) all of the criteria in Chapter XI.M21 of the GALL. Therefore, this is a partial match. Additionally, the attributes of the credited program meet the intent of a GALL Chapter

Page 382: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 382 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

XI program (XI.M2) attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation.

RC1d RC Piping/Tubing - RCP Thermal Barrier (less than NPS 4 inch)

PB Stainless Steel Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1d RC Pumps (Casing Only) (XPP0030A/B/C), RCP

PB CASS Borated Water

Thermal Aging Reduction of Fracture Toughness

In-Service Inspection (ISI) Plan

See Notes A-RC1d-b, A-RC1d-g.

IV.C2.3-c, IV.C2.3.1

T.1-23 No Yes The material, environment, aging effects/mechanisms requiring management, and the credited program for this sub-component are consistent with the identified GALL item. The attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1d RC Pumps (Casing Only) (XPP0030A/B/C), RCP

PB CASS Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX.

N/A N.1-01 N/A N/A Chapter IV of the GALL does not evaluate external environments for this component type/material. For VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable reference.

RC1d RC Pumps (Casing Only) (XPP0030A/B/C), RCP

PB CASS Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1d-a, A-RC1d-g.

IV.C2.3-b, IV.C2.3.1

T.1-36, N.1-07

No Partial The material, environment, aging effects/mechanisms requiring management, and credited program for this sub-component are consistent with the identified GALL item. However, the credited program alone, rather than being supplemented by Inservice Inspection or taking explicit credit for material selection as recommended by GALL, was determined to provide adequate management of the conditions that could result in the specified aging effects. The primary focus of ISI is on connections/junctures, such as welded joints, for Class 1 components and, therefore, this component is not applicable. The attributes of the credited program meet the intent of the corresponding GALL Chapter XI program (XI.M2) attributes for the Reactor Coolant System. Certain aging effects not addressed by the GALL (crevice and pitting corrosion)are also managed by the credited program for this sub-component. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively

Page 383: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 383 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1e RC Tank (XTK0024) - PZR Head (Lower)

PB Alloy Steel - SA-533, Gr. A, Cl. 2

Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack); Flaw Growth at Welds (cyclic loading)

Loss of Material; Cracking

Boric Acid Corrosion Surveillances; In-Service Inspection (ISI) Plan

See Notes A-RC1e-a, A-RC1e-b.

IV.C2.5-b, IV.C2.5.1; IV.C2.5-u, IV.C2.5.12; IV.C2.5-v, IV.C2.5.12

T.1-38, T.1-41

No Yes The identified GALL items address boric acid corrosion of alloy steel Pressurizer external surfaces, including the integral support (IV.C2.5.12). Additionally, GALL item IV.C2.5-v addresses cracking of the integral support weld due to cyclic loading resulting in the growth of flaws at the support skirt/lower head interface. The material, environment, aging effect(s)/mechanism(s) requiring management, and the credited programs for this sub-component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, credited program. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of each program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M10 and XI.M1 respectively).

RC1e RC Tank (XTK0024) - PZR Head (Lower)

PB Stainless Steel Cladding - E308L &/or E309L

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds (cyclic loading)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

Cladding; See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-c, IV.C2.5.1

T.1-36, N.1-07

No Yes The identified GALL item addresses crack initiation and growth for stainless steel Pressurizer shell/head cladding. The material, environment, aging effect(s)/mechanism(s) requiring management, and the credited programs for this sub-component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism and credited program. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the Chemistry program. Additionally, the attributes of the credited programs, as applied to Class 1 components, meet the intent of the corresponding GALL Chapter XI programs. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs (XI.M2 and XI.M1 respectively).

RC1e RC Tank (XTK0024) - PZR Head (Upper)

PB Stainless Steel Cladding - E308L &/or

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program; In-Service Inspection

Cladding; See Notes A-RC1e-c, A-

IV.C2.5-c, IV.C2.5.1

T.1-36, N.1-07

No Yes The identified GALL item addresses crack initiation and growth for stainless steel Pressurizer shell/head cladding. The material,

Page 384: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 384 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

E309L Cracking (SCC), Flaw Growth at Welds (cyclic loading)

(ISI) Plan RC1e-d environment, aging effect(s)/mechanism(s) requiring management, and the credited programs for this sub-component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism and credited program. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the Chemistry program. Additionally, the attributes of the credited programs, as applied to Class 1 components, meet the intent of the corresponding GALL Chapter XI programs. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs (XI.M2 and XI.M1 respectively)

RC1e RC Tank (XTK0024) - PZR Head (Upper)

PB Alloy Steel - SA-533, Gr. A, Cl. 2

Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1e-a, A-RC1e-b.

IV.C2.5-b, IV.C2.5.1

T.1-38 No Yes The identified GALL item addresses boric acid corrosion of alloy steel pressurizer external surfaces. The material, environment, aging effect(s)/mechanism(s) requiring management, and the credited activities for this component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, and credited program. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M10).

RC1e RC Tank (XTK0024) - PZR Immersion Heater Well Assemblies

PB Stainless Steel - SA-182, Gr. F316

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX, WCAP-14574-A

N/A N.1-01 N/A N/A The sub-component AMR result is for a material and environment combination that is not addressed in GALL Chapters IV, V, VII and VIII (GALL item V.C.1-b addresses the material and includes the environment, along ironment with the internal environment, however, the aging effects for this GALL item are focused on the internal environment effects). Also, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1e RC Tank (XTK0024) - PZR Immersion Heater Well Assemblies

PB Stainless Steel - SA-182, Gr. F316

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-r, IV.C2.5.10

T.1-36, N.1-07

No Partial The identified GALL item addresses crack initiation and growth for austenitic stainless steel heater sheathes and sleeves. The

Page 385: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 385 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Cracking (SCC) material, environment, aging effect)/mechanism requiring management, and the credited program for this component are consistent with the identified GALL item, except as clarified. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the Chemistry program. While the GALL item specifies both Chemistry (XI.M2) and ISI (XI.M2) for management, VCSNS determined that the Chemistry Program provides adequate management of the conditions that could lead to the onset and propagation of cracks in the sub-componenets. Additionally, the attributes of the credited program, as it is applied to the environments to which Class 1 components are exposed, meets the intent of a GALL Chapter XI programs. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1e RC Tank (XTK0024) - PZR Manway Cover

PB Stainless Steel Insert

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-m, IV.C2.5.8

N.1-07, N.1-11

No Partial The identified GALL item addresses crack initiation and growth for manway and flanges (stainless steel and/or nickel-based cladding). The material (stainless steel insert), environment, aging effect/mechanism requiring management, and the credited program for this sub-component are consistent with the identified GALL item, except as clarified. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the Chemistry program. While the GALL item specifies both Chemistry (XI.M2) and ISI (XI.M2) for management, VCSNS determined that the Chemistry Program provides adequate management of the conditions that could lead to the onset and propagation of cracks in the sub-component. Additionally, the attributes of the credited program, as it is applied to the environments to which Class 1 components are exposed, meets the intent of a GALL Chapter XI programs. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1e RC Tank (XTK0024) - PZR PB Alloy Steel - Reactor Boric Acid Corrosion Loss of Material Boric Acid See Notes A- IV.C2.5-o, T.1-38 No Yes The material, environment, aging

Page 386: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 386 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Manway Cover (& Bolts) SA-533, Gr. B, Cl. 1

Building (Aggressive Chemical Attack)

Corrosion Surveillances

RC1e-a, A-RC1e-b

IV.C2.5.8, IV.C2.5.9

effect(s)/mechanism(s) requiring management, and the credited activities for this sub-component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, and credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M10).

RC1e RC Tank (XTK0024) - PZR Manway Cover Bolts/Studs

PB Alloy Steel - SA-193, Gr. B7

Reactor Building

Stress Relaxation, Loss of Preload, Stress Corrosion Cracking (SCC)

Loss of Mechanical Closure Integrity

In-Service Inspection (ISI) Plan

See Note A-RC1e-e

IV.C2.5-n, IV.C2.5-p, IV.C2.5.9

T.1-26 No Partial The identified GALL items address crack initiation and growth as well as loss of preload for high strength low alloy steel bolting. The sub-component AMR results are consistent with the identified GALL items in terms of material, environment and aging effect/mechanism requiring management. However, the "In-Service Inspection (ISI) Plan", which is credited for management of these aging effects, meets the intent of GALL program XI.M.18, "Bolting Integrity" as it applies to bolting of class 1 components. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation.

RC1e RC Tank (XTK0024) - PZR Nozzle & Manway Forgings

PB Stainless Steel Cladding - E308L &/or E309L

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds (cyclic loading)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

Cladding; See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-g, IV.C2.5.2, IV.C2.5.3

T.1-36, N.1-07

No Partial The identified GALL item addresses crack initiation and growth for stainless spray and surge nozzle cladding. The material, environment, aging effect/mechanism requiring management, and the credited programs for this sub-component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism and credited program, except as clarified. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the "Chemistry program". Likewise, cracking due to flaw growth (cyclic loading), that is not addressed for the identified GALL item, is managed by the In-Service Inspection (ISI) Plan. Also, VCSNS determined that the Chemistry Program provides adequate management of the conditions that could result in stress corrosion cracking. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI

Page 387: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 387 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

programs (XI.M2 and XI.M1 respectively). Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1e RC Tank (XTK0024) - PZR Nozzle & Manway Forgings

PB Alloy Steel - SA-508, Cl. 2

Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1e-a, A-RC1e-b.

IV.C2.5-b, IV.C2.5.1

T.1-38 No Yes The material, environment, aging effect/mechanism requiring management, and the credited activities for this sub-component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing agingduring the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M10).

RC1e RC Tank (XTK0024) - PZR Nozzle Safe Ends

PB Stainless Steel - SA-182, Gr. F316L

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX, WCAP-14574-A

N/A N.1-01 N/A N/A The sub-component AMR result is for a material and environment combination that is not addressed in GALL Chapters IV, V, VII and VIII (GALL item V.C.1-b addresses the material and includes the environment, along ironment with the internal environment, however, the aging effects for this GALL item are focused on the internal environment effects). Also, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1e RC Tank (XTK0024) - PZR Nozzle Safe Ends

PB Stainless Steel - SA-182, Gr. F316L

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-h, IV.C2.5.7

T.1-36, N.1-07

No Yes The identified GALL item addresses crack initiation and growth for stainless steel safe ends. The material, environment, aging effect/mechanism requiring management, and the credited programs for this component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism and credited program. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the "Chemistry program". Additionally, the attributes of the credited programs meet the intent of the corresponding GALL Chapter XI programs (XI.M2 and XI.M1 respectively). Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of

Page 388: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 388 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

extended operation and in meeting the intent of the pertinent GALL programs.

RC1e RC Tank (XTK0024) - PZR Nozzle Thermal Sleeves

HT Stainless Steel - SA-213&240, Type 304

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds (cyclic loading)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-g, IV.C2.5.2, IV.C2.5.3

T.1-36, N.1-07

No Partial The identified GALL item addresses crack initiation and growth for stainless steel spray and surge nozzles. The material, environment, aging effect/mechanism requiring management, and the credited programs for this sub-component (surge & spray nozzle thermal sleeves) AMR results are consistent with the identified GALL item, as clarified. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the "Chemistry program". Cracking due to flaw growth, which is not specified for the GALL item, is managed by the ISI Plan. However, the ISI Plan is not credited for management of SCC at VCSNS (Chemistry Program is), but the associated ISI actions serve as added confirmation of the effectiveness of chemistry control. Additionally, the attributes of the credited programs meet the intent of corresponding GALL Chapter XI programs (XI.M2 and XI.M1 respectively). Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1e RC Tank (XTK0024) - PZR Nozzle-Safe End Weld Metal

PB Nickel-Based Alloy - Alloy 82/182 Buttering

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds (cyclic loading); Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan; Alloy 600 Aging Management Program

See Notes A-RC1e-f, A-RC1e-g

IV.C2.5-k, IV.C2.5.6

T.1-14, N.1-07

Yes, an AMP for PWSCC of Inconel 182 weld is to be evaluated.

No The identified GALL ittem addresses alloy 600 instrument penetrations rather than inconel 82/182 weld metal. The sub-component AMR results are consistent with identified GALL item in material, environment, and aging effect/mechanism requring management. Additionally, aging effects for stainless steel in the same environment (crevise & pitting corrosion, SCC) are conservatively managed for the nickel-based alloy weld metal. Also, the programs credited for management of these aging effects (not addressed for the GALL item) are consistent with corresponding GALL Chapter XI programs (XI.M2 and XI.M1 respectively). Also, the closest GALL chapter XI program, with regards to attributes for effective management, is XI.M11. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation.

Page 389: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 389 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RC1e RC Tank (XTK0024) - PZR Nozzle-Safe End Weld Metal

PB Nickel-Based Alloy - Alloy 82/182 Weld Buttering

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX, WCAP-14574-A

N/A N.1-02 N/A N/A The sub-component AMR result is for a material and environment combination that is not addressed in GALL Chapters IV, V, VII and VIII (GALL item V.C.1-b addresses a similar material (stainless steel) and includes the environment, along ironment with the internal environment, however, the aging effects for this GALL item are focused on the internal environment effects). Also, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1e RC Tank (XTK0024) - PZR Shell Barrel

PB Alloy Steel - SA-533, Gr. A, Cl. 2

Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1e-a, A-RC1e-b.

IV.C2.5-b, IV.C2.5.1

T.1-38 No Yes The identified GALL item addresses boric acid corrosion of alloy steel Pressurizer external surfaces. The material, environment, aging effect(s)/mechanism(s) requiring management, and the credited activities for this sub-component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism, credited program. Additionally, the attributes of the credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this program/activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M10).

RC1e RC Tank (XTK0024) - PZR Shell Barrel

PB Stainless Steel Cladding - E308L &/or E309L

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds (cyclic loading)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

Cladding; See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-c, IV.C2.5.1

T.1-36, N.1-07

No Yes The identified GALL item addresses crack initiation and growth for stainless steel shell/head sub-components. The material, environment, aging effect/mechanism requiring management, and the credited programs for this component are consistent with the identified GALL item which has the same material, environment, aging effect/mechanism and credited programs. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the "Chemistry program". Cracking due to flaw growth, which is not specified for the GALL item, is managed by the ISI Plan. However, the ISI Plan is not credited for management of SCC at VCSNS (Chemistry Program is), but the associated ISI actions serve as added confirmation of the effectiveness of chemistry control. Additionally, the attributes of the credited programs meet the intent of corresponding GALL Chapter XI programs (XI.M2 and XI.M1

Page 390: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 390 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

respectively). Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1e RC Tank (XTK0024) - PZR Tube Couplings (Instrument and Sample)

PB Stainless Steel - SA-182, Gr. F316

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX, WCAP-14574-A

N/A N.1-01 N/A N/A The sub-component AMR result is for a material and environment combination that is not addressed in GALL Chapters IV, V, VII and VIII (GALL item V.C.1-b addresses the material and includes the environment, along ironment with the internal environment, however, the aging effects for this GALL item are focused on the internal environment effects). Also, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1e RC Tank (XTK0024) - PZR Tube Couplings (Instrument and Sample)

PB Stainless Steel - SA-182, Gr. F316

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-g, IV.C2.5.6

T.1-36, N.1-07

No Partial The identified GALL item addresses crack initiation and growth for instrument penetrations. The material, environment, aging effect/mechanism requiring management, and the credited program for this sub-component are consistent with the identified GALL item, except as clarified. Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the Chemistry program. While the GALL item specifies both Chemistry (XI.M2) and ISI (XI.M2) for management, VCSNS determined that the Chemistry Program provides adequate management of the conditions that could lead to the onset and propagation of cracks in the sub-component. Additionally, the attributes of the credited program, as it is applied to the environments to which Class 1 components are exposed, meets the intent of a GALL Chapter XI programs. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1e RC Tank (XTK0024) - PZR Tubing (Instrument and Sample Lines)

PB Stainless Steel, SA-213, TP-316

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1e-c, A-RC1e-d

IV.C2.5-g, IV.C2.5.6

T.1-36, N.1-07

No Partial The identified GALL item addresses crack initiation and growth for instrument penetrations. The material, environment, aging effect/mechanism requiring management, and the credited program for this sub-component are consistent with the identified GALL item, except as clarified.

Page 391: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 391 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Certain aging effects (e.g. loss of material due to crevice & pitting corrosion) not addressed by the GALL item are also managed by the Chemistry program. While the GALL item specifies both Chemistry (XI.M2) and ISI (XI.M2) for management, VCSNS determined that the Chemistry Program provides adequate management of the conditions that could lead to the onset and propagation of cracks in the sub-component. Additionally, the attributes of the credited program, as it is applied to the environments to which Class 1 components are exposed, meets the intent of a GALL Chapter XI programs. Refer to TR00160-020 for a detailed discussion of the attributes of these programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1e RC Tank (XTK0024) - PZR Tubing (Instrument and Sample Lines)

PB Stainless Steel, SA-213, TP-316

Reactor Building

None Identified None Identified None Required TR00160-010 Attachment XI, WCAP-14575-A

N/A N.1-01 N/A N/A The sub-component AMR result is for a material and environment combination that is not addressed in GALL Chapters IV, V, VII and VIII (GALL item V.C.1-b addresses the material and includes the environment, along ironment with the internal environment, however, the aging effects for this GALL item are focused on the internal environment effects). Also, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1f RC Channel Head & Inlet/Outlet Nozzles (XSG0002A/B/C)

PB Alloy Steel clad w/ Austenitic Stainless Steel

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds

Loss of Material; Cracking (cladding)

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1f-c and A-RC1f-d.

IV.D1.1-i, IV.D1.1.9

T.1-44, N.1-07

No Yes GALL item IV.D1.1-i addresses stress corrosion cracking of the primary nozzles. The material, environment, aging effect/mechanism and credited programs are consistent with the identified GALL item, except as clarified. Certain aging mechanisms (crevice and pitting corrosion and flaw growth) not addressed by the GALL item are also managed by the credited programs. Also, the Inconel buttering and weld material are addressed with a separate VCSNS AMR result. Although the GALL item only specifies the nozzles, the channel head is considered susceptible to the same aging effects at VCSNS. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL chapter XI programs (XI.M2 and XI.M1 respectively) attributes, as the programs are applied to Class 1 components. Refer to TR00160-020 for a detailed discussion of the attributes of the

Page 392: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 392 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1f RC Channel Head & Inlet/Outlet Nozzles (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g, IV.D1.1.8

T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1f RC Channel Head Divider Plate (XSG0002A/B/C)

PB Nickel-Based Alloy (Alloy 690 TT)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds, Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking (cladding)

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1-e and A-RC1f-f.

IV.D1.1-i, IV.D1.1.9

T.1-44, N.1-07

No Yes GALL item IV.D1.1-i addresses stress corrosion cracking of the primary nozzles. The material, environment, aging effect/mechanism and credited programs are consistent with the identified GALL item, except as clarified. Certain aging mechanisms (crevice and pitting corrosion and flaw growth) not addressed by the GALL item are also managed by the credited programs. Also, the Alloy 690 TT divider plate is not considered susceptible to PWSCC and the Inconel 82/182 welds attaching the plate to the tubeplate and channel head have Inconel 152 final layers that preclude contact with primary water. However, the ISI Plan will address PWSCC should it become evident in the Alloy 690 TT/ Inconel 152. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL chapter XI programs (XI.M2 and XI.M1 respectively) attributes, as the programs are applied to Class 1 components. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1f RC Closure Bolting (Primary and Secondary Side)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a, A-RC1f-b.

IV.D1.1-k T.1-38 No Yes GALL item IV.D1.1-k addresses loss of material due to boric acid corrosion of primary bolting (IV.D1.1.11). The sub-component AMR result is consistent with the identified item with respect to material, environment, aging effects requiring management, and

Page 393: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 393 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

credited aging management programs/activities. However, the activities credited to address boric acid corrosion at VCSNS include both primary and secondary bolting. The attributes of the credited activities meet the intent of a corresponding GALL chapter XI program (XI.M10) attributes, as the activities are applied to Class 1 components and Class 2 steam generator sub-components. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation.

RC1f RC Closure Bolting (Primary and Secondary Side)

PB Alloy Steel Reactor Building

Loss of Preload, Stress Corrosion Cracking (SCC)

Loss of Mechanical Closure Integrity

In-Service Inspection (ISI) Plan

See Notes A-RC1f-a, A-RC1f-b.

IV.D1.1-f, IV.D1.1-l

T.1-26 No Partial GALL item IV.D1.1-f and IV.D1.1.l address loss of preload due to stress relaxation of the secondary side bolting (IV.D1.1.7) and cracking due to stress corrosion cracking of primary bolting (IV.D1.1.11) as a result of boric acid exposure respectively. The sub-component AMR result is consistent with the identified GALL items with respect to material, environment, aging effects requiring management as clarified, and credited aging management program as clarified. The aging effects that the GALL items refer to (loss of preload / crack initiation and growth) are considered "loss of mechanical closure integrity" at VCSNS. However, the corresponding mechanisms that the GALL items refer to are considered to result in the above aging effect at VCSNS. Additionally, while the GALL items differentiate between secondary side bolting (loss of preload) and primary side bolting (cracking), VCSNS conservatively considered all Steam Generator closure bolting to be susceptible to both mechanisms. Furthermore, SCC is only applicable to high strength bolts (yield strengths > 150ksi). SA-193 and 194 closure material utilized at VCSNS typcially has a yield strength of 105 ksi and is not strictly high strength. However, the ISI Plan, as it applies to Steam Generator closure bolting, rather than a separate "Bolting Intergrity" program as specified by the GALL items (IV.D1.1-f and IV.D1.1-l), is credited for management of both loss of preload and SCC in primary and secondary side closure material. The attributes of the credited program meet the intent of a corresponding GALL chapter

Page 394: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 394 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

XI program (XI.M1) attributes, as the programs are applied to Class 1 components and pertinent Steam Generator sub-components. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation.

RC1f RC External Support Attachments - Lifting Lugs, Support Pads, Barrel Trunnions (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1f RC Feedwater Distribution Pipe & Fittings (XSG0002A/B/C)

PB, TH Alloy Steel (Chrome-Moly)/Nickel-Based Alloy

Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1f-g and A-RC1f-j.

IV.D1.1-d; IV.D1.1-e, IV.D1.3-a

N.1-10 No; Yes, Plant specific No Although GALL item IV.D1.1-d does address flow-accelerated corrosion of the steam and feedwater nozzle and safe end (IV.D1.1.2 and IV.D1.1.5 respectively) while IV.D1.1-e addresses erosion of the feedwater impingement plate and support (IV.D1.1.6), the material for both of these GALL items is carbon steel. Also, GALL item IV.D1.3-a addressed flow-accelerated corrosion of feedwater inlet rings in CE system 80 generators (also carbon steel). As described in the applicable note, the chrome-moly alloy steel is not a low-alloy steel (but is closer to a stainless steel). As such, the distribustion pipe and fittings in the Delta-75 SGs are resistant to both erosion and erosion/corrosion. However, the sub-component is considered susceptible to the same aging effects as other stainless steels exposed to treated water/steam. Therefore, the Chemistry Program is credited for the management of the conditions leading to the onset and propogation of these effects. Additionally, the attributes of the Chemistry Program, as it is applied to the secondary side steam generator environment, are consistent with the asttributes of a program evaluated in GALL Chapter XI (XI.M2). Refer to TR00160-020 for a detailed discussion of the attributes of this program in managing

Page 395: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 395 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

aging during the period of extended operation.

RC1f RC Manway Covers - Primary Side (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-k, IV.D1.1.11

T.1-38 No Yes GALL Item IV.D1.1-k addresses boric acid corrosion on the external surface of the primary manway cover. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1f RC Manway Covers Insert Plates - Primary Side (XSG0002A/B/C)

PB Stainless Steel Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1f-g and A-RC1f-h.

IV.D1.1-i N.1-07, N.1-11

No Partial GALL item IV.D1.1-i (refered to herein as IV.D1.1-ii) addresses stress corrosion cracking of the primary nozzles/safe ends. The material, environment, aging effect/mechanism and credited programs are consistent with the identified GALL item, excpet as clarified. Certain aging mechanisms (crevice and pitting corrosion) not addressed by the GALL item are also managed by the credited program. However, VCSNS determined that the Chemistry Program was sufficient for management of the manway cover insert, which is not specifically addressed in the GALL. Also, the cover insert plates are not susceptible to PWSCC, which is specified for the GALL item along with nickel based material (in addition to stainless steel), and the ISI program is not required for management of aging of the sub-component. Additionally, the attribute of the credited program meets the intent of the corresponding GALL chapter XI program (XI.M2) attributes, as applied to Class 1 components. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1f RC Manway, Handhole, Sludge Collector Opening & Inspection Port Covers - Secondary Side (XSG0002A/B/C)

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Note A-RC1f-ii and A-RC1f-j

IV.D1.1-c, IV.D1.1.3

N.1-03 Yes, detection of aging effects is to be evaluated

Partial GALL item IV.D1.1-c addresses corrosion of the upper and lower shells and transition cone, to which the sub-components are attached at VCSNS. The material, environment, and aging effect/mechanisms for this sub-component AMR result are

Page 396: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 396 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

consistent with the identified GALL item. However, VCSNS determined that the Chemistry Program provides adequate management for the secondary side covers, which are not specifically addressed in GALL chapter IV. IN 90-04, which is referenced for the GALL item as the basis for enhanced detection of aging effects in the shell, addressed flaw growth at welds due to service loading. The IN contains only general indication that pits on the surface may have served as crack initiation sites, and not that pitting corrosion resulted in sufficient degradation to cause loss of component function. Cracking due to flaw growth is managed for applicable sub-components at VCSNS. Refer to TR00160-020 for a detailed discussion of the effectiveness of the credited program in managing aging during the period of extended operation and in meeting the intent of a GALL chapter XI program (XI.M2).

RC1f RC Manway, Handhole, Sludge Collector Opening & Inspection Port Covers - Secondary Side (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1f RC Manways, Handholes, Sludge Collector Opening & Inspection Ports - Secondary Side (XSG0002A/B/C)

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion; Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1f-ii and A-RC1f-j.

IV.D1.1-c, IV.D1.1.3

N.1-03 Yes, detection of aging effects is to be evaluated

Partial GALL item IV.D1.1-c addresses corrosion of the upper and lower shells and transition cone, of which the sub-components are integral at VCSNS. The material, environment, aging effect/mechanisms, and credited aging management programs for this sub-component AMR result are consistent with the identified GALL item, except as clarified. IN 90-04, which is referenced for the GALL item as the basis for enhanced detection of aging effects in the shell, addressed flaw growth at girth welds due to service loading. The IN contains only general indication that pits on the surface served as crack initiation sites, and not that pitting corrosion resulted in sufficient degradation to cause loss of component function. No

Page 397: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 397 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

subsequent industry experience has further identified pitting corrosion resulting in reportable indications for the shell. Cracking due to flaw growth is managed at VCSNS by the ISI Plan. Refer to TR00160-020 for a detailed discussion of the effectiveness of the credited programs in managing aging during the period of extended operation and in meeting the intent of a GALL chapter XI programs (XI.M2 and XI.M1 respectively).

RC1f RC Manways, Handholes, Sludge Collector Opening & Inspection Ports - Secondary Side (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program

RC1f RC Nozzle - Inlet/Outlet - Closure Ring & Weld Metal (XSG0002A/B/C)

PB Nickel-Based (Alloy 690 TT w/ Alloy 600 butter)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds, Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1-e and A-RC1f-f.

IV.D1.1-i, IV.D1.1.9

T.1-44, N.1-07

No Partial GALL item IV.D1.1-i addresses stress corrosion cracking of the primary nozzles. The material, environment, aging effect/mechanism and credited programs are consistent with the identified GALL item, except as clarified. Certain aging mechanisms (crevice and pitting corrosion and flaw growth) not addressed by the GALL item are also managed by the credited programs. Also, the Alloy 690 TT closure ring is not of a material that is considered to be susceptible to PWSCC while the Inconel 82/182 welds attaching the rings to the nozzles have Inconel 152 final layers that preclude contact with primary water. However, the ISI Plan will manage PWSCC in the event that the materials begin to evidence susceptibility during the period of extended operation. Additionally, the attributes of the credited programs meet the intent of the corresponding GALL chapter XI programs (XI.M2 and XI.M1 respectively) attributes, as the programs are applied to Class 1 components. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent

Page 398: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 398 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL programs. RC1f RC Nozzle - Secondary Side

Auxiliary Feedwater (XSG0002A/B/C)

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion; Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1f-ii and A-RC1f-j.

IV.D1.1-c, IV.D1.1.3

N.1-03 Yes, detection of aging effects is to be evaluated.

Partial GALL item IV.D1.1-c addresses corrosion of the upper and lower shells and transition cone, to which the sub-components are integral at VCSNS. The material, environment, aging effect/mechanisms, and credited aging management programs for thissub-component AMR result are consistent with the identified GALL item, except as clarified. However, VCSNS determined that the Chemistry Program provides adequate management for the secondary side nozzles, from general, crevice and pitting corrosion. Also, cracking as the result of flaw growth is an aging effect/mechanism that is managed at VCSNS by the ISI plan. IN 90-04, which is referenced for the GALL item as the basis for enhanced detection of aging effects in the shell, addressed flaw growth at girth welds due to service loading. The IN contains only general indication that pits on the surface served as crack initiation sites, and not that pitting corrosion resulted in sufficient degradation to cause loss of component function. No subsequent industry experience has further identified pitting corrosion resulting in reportable indications for the shell. Cracking due to flaw growth is managed at VCSNS by the ISI Plan. Refer to TR00160-020 for a detailed discussion of the effectiveness of the credited programs in managing aging during the period of extended operation and in meeting the intent of a GALL chapter XI programs (XI.M2 and XI.M1 respectively).

RC1f RC Nozzle - Secondary Side Auxiliary Feedwater/Feedwater (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1f RC Nozzle - Secondary Side Feedwater

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion,

Loss of Material; Cracking

Chemistry Program; In-

See Notes A-RC1f-ii and A-

IV.D1.1-d, IV.D1.1.5

N.1-03 No No GALL item IV.D1.1-d addresses flow-accelerated corrosion of the Feedwater

Page 399: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 399 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

(XSG0002A/B/C) Pitting Corrosion; Flaw Growth at Welds

Service Inspection (ISI) Plan

RC1f-j. Nozzle. The sub-component AMR result is consistent with the identified GALL item with regard to material and environment, but not in aging effect(s)/mechanism(s) requiring management or in credited program. Also, the nickel-based thermal sleeve (discussed separately below) that is installed in the nozzle precludes adverse impacts to the nozzle due to flow-accelerated corrosion. Furthermore, GALL item IV.D1.1-c addresses corrosion of the upper and lower shells. At VCSNS, the feedwater nozzle is integral to the shell and susceptible to the same aging mechanisms (general, pitting, and crevice corrosion). Cracking due to flaw growth is an aging effect that is not addressed for the identied GALL item (IV.D1.1-c), but is managed at VCSNS by the ISI plan. Refer to TR00160-020 for a detailed discussion of the attributes of these credited programs in managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs (XI.M2 and XI.M1 respectively).

RC1f RC Nozzle Safe Ends - Primary Side (XSG0002A/B/C)

PB Stainless Steel w/ Nickel-Based weld material

Reactor Building

None Identified None Identified None Required TR00160-010, Attachment IX and WCAP-14757

N/A N.1-02 N/A N/A The material/enviroment combination for this sub-component is not addressed for any GALL item in chapters IV, V, VII, or VIII. Also no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC1f RC Nozzle Safe Ends - Primary Side(XSG0002A/B/C)

PB Stainless Steel w/ Nickel-Based weld material

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds, Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1f-e, A-RC1f-f, A-RC1f-g and A-RC1f-h

IV.D1.1-i, IV.D1.1.9

T.1-44, N.1-07

No Yes GALL item IV.D1.1-i addresses stress corrosion cracking of the primary nozzles/safe ends. The material, environment, aging effect/mechanisms and credited programs are consistent with the identified GALL item, as clarified. Certain aging mechanisms (crevice and pitting corrosion and flaw growth) not addressed by the GALL item are also managed by the credited program/programs. Additionally, the attribute of the credited program meets the intent of the corresponding GALL chapter XI programs (XI.M2 and XI.M1 respectively) attributes, as applied to Class 1 components. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs.

RC1f RC Nozzle Thermal Sleeve - Secondary Side Auxiliary

HT Nickel-Based Alloy (Alloy 690

Treated Water

Crevice Corrosion, Pitting Corrosion;

Loss of Material; Cracking

Chemistry Program; In-

Sleeve and attachment

IV.D1.2-b N.1-08, N.1-09

Yes, effectiveness of the AMP is to be

Partial GALL item IV.D1.2-b addresses cracking of Alloy 600 tubes and sleeves. The sub-

Page 400: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 400 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Feedwater (XSG0002A/B/C)

TT) Stress Corrosion Cracking (SCC); Flaw Growth at Welds

Service Inspection (ISI) Plan

cladding; See Notes A-RC1f-k and A-RC1f-l.

evaluated component AMR results are consistent with the identified GALL item in material (no listing of Alloy 690), environment, and aging effect requiring management (stress corrosion cracking). Certain aging effects not addressed for this GALL item are also managed by the credited programs (crevice and pitting corrosion and flaw growth). Additionally, the credited programs, as they are applied to Class 1 components, are consistent with GALL Chapter IX programs (XI.M2 and XI.M1 respectively), whereas the GALL item identifies programs that are focused on the tubes instead of secondary side thermal sleeves. As such, the GALL recommendation for effectiveness verification is not applicable to the secondary side nozzle thermal sleeves. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs (XI.M2 and XI.M1).

RC1f RC Nozzle Thermal Sleeve - Secondary Side Feedwater (XSG0002A/B/C)

HT Nickel-Based Alloy (Alloy 690 TT)

Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

Sleeve and attachment cladding; See Notes A-RC1f-k and A-RC1f-l.

IV.D1.2-b N.1-08, N.1-09

Yes, effectiveness of the AMP is to be evaluated

Partial GALL item IV.D1.2-b addresses cracking of Alloy 600 tubes and sleeves. The sub-component AMR results are consistent with the identified GALL item in material (no listing of Alloy 690), environment, and aging effect requiring management (stress corrosion cracking). Certain aging effects not addressed for this GALL item are also managed by the credited programs (crevice and pitting corrosion and flaw growth). Additionally, the credited programs, as they are applied to Class 1 components, are consistent with GALL Chapter IX programs (XI.M2 and XI.M1 respectively), whereas the GALL item identifies programs that are focused on the tubes instead of secondary side thermal sleeves. As such, the GALL recommendation for effectiveness verification is not applicable to the secondary side nozzle thermal sleeves. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs (XI.M2 and XI.M1).

RC1f RC Shell - Upper and Lower Barrel, Transition Cone, Elliptical Head (XSG0002A/B/C)

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion; Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

See Notes A-RC1f-ii and A-RC1f-j.

IV.D1.1-c, IV.D1.1.3, IV.D1.1.4

T.1-02 Yes, detection of aging effects is to be evaluated.

Partial IV.D1.1-c address corrosion of the upper and lower shell and the transition cone. The sub-component AMR results are consistent with the identified GALL item with regards to material, environment, aging effects requiring

Page 401: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 401 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management, and credited programs, except as clarified. Certain aging effects (cracking due to flaw growth) not specified for the identified GALL item are managed by the credited programs. IN 90-04, which is referenced for the GALL item as the basis for enhanced detection of aging effects in the shell, addressed flaw growth at girth welds due to service loading. The IN contains only general indication that pits on the surface served as crack initiation sites, and not that pitting corrosion resulted in sufficient degradation to cause loss of component function. No subsequent industry experience has further identified pitting corrosion resulting in reportable indications for the shell. Cracking due to flaw growth is managed at VCSNS by the ISI Plan. Refer to TR00160-020 for a detailed discussion of the effectiveness of the credited programs in managing aging during the period of extended operation and in meeting the intent of a GALL chapter XI programs (XI.M2 and XI.M1 respectively).

RC1f RC Shell - Upper and Lower Barrel, Transition Cone, Elliptical Head (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g, IV.D1.1.8

T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program

RC1f RC Steam Outlet Nozzle (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the

Page 402: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 402 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

intent of the pertinent GALL program. RC1f RC Steam Outlet Nozzle

Flow Limiter (XSG0002A/B/C)

PB, TH Nickel-Based Alloy (Alloy 690 TT)

Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC); Flaw Growth at Welds

Loss of Material; Cracking

Chemistry Program; In-Service Inspection (ISI) Plan

Both Flow limiter and connecting weld metal; See Notes A-RC1f-k and A-RC1f-l.

IV.D1.2-b N.1-08, N.1-09

Yes, effectiveness of AMP is to be evaluated

Partial GALL item IV.D1.2-b addresses cracking of Alloy 600 tubes and sleeves. The sub-component AMR results are consistent with the identified GALL item in material (no listing of Alloy 690), environment, and aging effect requiring management (stress corrosion cracking). Certain aging effects not addressed for this GALL item are also managed by the credited programs (crevice and pitting corrosion and flaw growth). Additionally, the credited programs, as they are applied to Class 1 components, are consistent with GALL Chapter IX programs (XI.M2 and XI.M1 respectively), whereas the GALL item identifies programs that are focused on the tubes instead of secondary side outlet nozzles. As such, the GALL recommendation for effectiveness verification is not applicable to the secondary side outlet nozzle. Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs (XI.M2 and XI.M1).

RC1f RC Taps - Blowdown, Drain, Level, Sample, Wet Layup (Plugged) (XSG0002A/B/C)

PB Alloy Steel Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Notes A-RC1f-ii, A-RC1f-j.

IV.D1.1-c, IV.D1.1.3, IV.D1.1.4

N.1-03 Yes, detection of aging effects is to be evaluated.

Partial GALL item IV.D1.1-c addresses corrosion of the upper and lower shell and the transition cone, of which the specified taps are integral. The sub-component AMR results are consistent with the identified GALL item with regards to material, environment, and aging effect requiring management as clarified. The GALL item specifies both Water Chemistry and Inservice Inspection. VCSNS determined that the Chemistry Program provides adequate management of the conditions in the taps. IN 90-04, which is referenced for the GALL item as the basis for enhanced detection of aging effects in the shell, addressed flaw growth at girth welds due to service loading. The IN contains only general indication that pits on the inner surface served as crack initiation sites, and not that pitting corrosion resulted in sufficient degradation to cause loss of component function. No subsequent industry experience has further identified pitting corrosion resulting in reportable indications for the shell, specifically in the vicinity of small taps. Refer to TR00160-020 for a detailed discussion of the attributes and effectiveness of the credited program in managing aging

Page 403: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 403 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

during the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M2).

RC1f RC Taps - Blowdown, Drain, Level, Sample, Wet Layup (Plugged) (XSG0002A/B/C)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head, but other portions of the Steam Generator were conservatively considered to be susceptible to boric acid accumulation. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program

RC1f RC Tube Bundle Wrapper, Wrapper Support and Downcomer - Secondary Side (XSG0002A/B/C)

Support Carbon Steel/Nickel-Based Alloy

Treated Water

Crevice Corrosion, General Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC) (nickel-based only)

Loss of Material; Cracking

Chemistry Program

see Notes A-RC1f-ii and A-RC1f-j.

IV.D1.1-c N.1-03, N.1-13

Yes, detection of aging effects is to be evaluated

Partial GALL item IV.D1.1-c addresses corrosion of the shell and transition cone. The GALL item provides the closest relation to the sub-component AMR results with regard to material, environment, and aging effect/mechanisms requiring management, as clarified. GALL item IV.D1.2-h (IV.D1.2.2) addresses tube supports and corresponds with regard to material and environment, but differs with respect to aging mechanism. Also, an aging effect (SCC of nickel-based portions) not addressed by the GALL item are also managed by the credited program. Additionally, IN 90-04, which is referenced for the GALL item as the basis for enhanced detection of aging effects in the shell, addressed flaw growth at girth welds due to service loading. The IN contains only general indication that pits on the surface served as crack initiation sites, and not that pitting corrosion resulted in sufficient degradation to cause loss of component function. Lastly, the tube bundle wrapper support portions of the Steam Generators are not strictly necessary for the Steam Generator(s) to perform the required function of pressure boundary, throttling or heat transfer. The wrapper support portions were, however, conservatively subjected to AMR. As such, the credited program was determined to provide sufficient aging management for the sub-component, that is to provide adequate

Page 404: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 404 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

management of the conditions that could result in internal support dedgradation. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation and in meeting the intent of a GALL Chapter XI program (XI.M2).

RC1f RC Tube Support Plates - Plates, AVBs, Flow Distribution Baffle - Secondary Side (XSG0002A/B/C)

Support Stainless Steel / Nickel Based Tips&Rings

Treated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program

See Notes A-RC1f-m and A-RC1f-n.

VII.C2.2-a N.1-13 No Partial GALL Chapters IV and VIII (Reactor Coolant and Steam & Power Conversion) do not include an item(s) with a stainless steel (or nickel-based) and treated water combination. GALL item VII.C2.2-a addresses crevice/pitting corrosion of stainless steel valves in treated water. Except as noted, the AMR results for this sub-component are consistent with the identified GALL item which have a similar material, environment, and aging effect/mechanism requiring management. Certain aging effects not addressed by the GALL item are also managed by the credited program. The GALL recommends a Closed-Cycle Cooling Water System AMP for the identified item. The Chemistry Program credited for VCSNS does not match all of the criteria in Chapter XI.M21 of the GALL, but is consistent with GALL progam XI.M2 as it affects this sub-component. Refer to TR00160-020 for a detailed discussion of the attributes of this program in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program (XI.M2).

RC1f RC Tubeplate - Secondary Side (XSG0002A/B/C-RC)

PB Alloy Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Notes A-RC1f-ii and A-RC1f-j

IV.D1.1-c N.1-03 Yes, detection of aging effects is to be evaluated

Partial GALL item IV.D1.1-c addresses corrosion of the upper and lower shells and transition cone. The tubeplate (secondary side) is connected to the lower shell. The material, environment, and aging effect requiring management for this sub-component are consistent with the identified GALL item. However, VCSNS determined that the Chemistry Program provides adequate management for the secondary side of the tubeplate, which is not specifically addressed in GALL chapter IV. IN 90-04, which is referenced for the GALL item as the basis for enhanced detection of aging effects in the shell, addressed flaw growth at girth welds due to service loading. The IN contains only general indication that pits on the surface served as crack initiation sites, and not that pitting corrosion resulted in sufficient degradation to cause loss of component

Page 405: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 405 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

function. No subsequent industry experience has further identified pitting corrosion resulting in reportable indications for the shell. Refer to TR00160-020 for a detailed discussion of the effectiveness of the credited program in managing aging during the period of extended operation and in meeting the intent of a GALL chapter XI program (XI.M2)

RC1f RC Tubeplate - Primary Side (XSG0002A/B/C-RC)

PB Alloy Steel clad w/ Nickel-Based weld (82/182)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Flaw Growth at Welds, Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material, Cracking (cladding)

Chemistry Program; In-Service Inspection (ISI) Plan; Alloy 600 Aging Management Program

See Notes A-RC1f-e and A-RC1f-f.

IV.D1.1-i T.1-44, N.1-07

No Partial GALL item IV.D1.1-i addresses stress corrosion cracking of the primary nozzles/safe ends and is the closest match to the identified sub-component. The material, environment, aging effect/mechanisms requiring management and credited programs are consistent with the identified GALL item, except as indicated. Certain aging mechanisms (crevice and pitting corrosion and flaw growth) not addressed by the GALL item are also managed by the credited program/programs. The Alloy 600 Aging Management Program is credited to manage the PWSCC of the Inconel 82/182 cladding rather than the combination of Chemistry and ISI, as specified for the GALL item. The attribute of the credited programs meet the intent of the corresponding GALL chapter XI programs (XI.M2 and XI.M1 respectively) attributes, as applied to Class 1 components. Also, the "Alloy 600 Aging Management Program" is a plant specific program, with the closest corresponding GALL chapter XI program being "Nickel-Alloy Nozzles and Penetrations (XI.M11). Refer to TR00160-020 for a detailed discussion of the attributes of the credited programs in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL programs, as applicable.

RC1f RC Tubeplate (XSG0002A/B/C-RC)

PB Alloy Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Notes A-RC1f-a and A-RC1f-b.

IV.D1.1-g T.1-38 No Yes GALL Item IV.D1.1-g addresses boric acid corrosion on the external surface of the steam generator lower head, to which the tubeplate (primary side) is attached. The tubeplate is roughly 29 inches thick [1MS-07-365]. The outer circumference of the tubeplate is open to the ambient conditions in the vicinity of each Steam Generator. The material, environment, aging effect requiring management and the credited activities for this sub-component are consistent with the identified GALL item. Additionally, the attributes of the credited activities meet the intent of the corresponding GALL Chapter XI program (XI.M10) program attributes. Refer

Page 406: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 406 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

to TR00160-020 for a detailed discussion of the attributes of the credited activities in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

RC1f RC Tubes - Secondary Side (XSG0002A/B/C-RC)

PB, HT Nickel-Based Alloy (Alloy 690 TT)

Treated Water

Crevice Corrosion, Pitting Corrosion, Wear (Fretting); Stress Corrosion Cracking (SCC)

Loss of Material; Cracking

Chemistry Program; Steam Generator Management Program

See Notes A-RC1f-k and A-RC1f-l.

IV.D1.2-b, IV.D1.2-c, IV.D1.2.1

T.1-18 Yes, effectiveness of the AMP is to be evaluated.

Yes Items IV.D1.2-b, and IV.D1.2-c and IV.D1.2-e address secondary side ODSCC, Intergranular Attack, and Fretting of the tube external surfaces respectively, rather than listing multiple aging mechanisms for a single GALL item even though the specified program and recommendations (as well as component, material, and environment) are the same for each item. The material, environment, aging effects/mechanisms, and credited programs for this sub-component are consistent with the identified GALL items combined. Additionally, certain aging mechanisms (crevice and pitting corrosion) not addressed by the GALL items are also managed by the credited programs. The identified GALL items indicate that program effectiveness is to be evaluated and that SG degradation management is to be incorporated in the plant technical specifications. Refer to TR00160-020 for a detailed discussion of the credited programs, particularly for the "Steam Generator Management Program" based on NEI 97-06 as incorporated into the Technical Specifications, in effectively managing aging during the period of extended operation and of meeting the intent of the pertinent GALL programs (XI.M2 and XI.M19).

RC1f RC Tubes/Plugs - Primary Side (XSG0002A/B/C)

PB, HT Nickel-Based Alloy (Alloy 690 TT)

Borated Water

Crevice Corrosion, Pitting Corrosion; Stress Corrosion Cracking (SCC), Primary Water Stress Corrosion Cracking (PWSCC)

Loss of Material; Cracking

Chemistry Program; Steam Generator Management Program

See Notes A-RC1f-e and A-RC1f-f.

IV.D1.2-a, IV.D1.2.1, IV.D1.2-i, IV.D1.2.3

T.1-18 Yes, effectiveness of the AMP is to be evaluated

Yes GALL items IV.D1.2-a and IV.D1.2-i address primary water stress corrosion cracking of the tubes (IV.D1.2.1) and tube plugs (IV.D1.2.3) respectively. The material, environment, aging effect/mechanism requiring management, and credited programs for this sub-component are consistent with the identified GALL items, as clarified. The identified GALL items indicate that program effectiveness is to be evaluated and that SG degradation management is to be incorporated in the plant technical specifications. Additionally, certain aging mechanisms (crevice and pitting corrosion) not addressed by the GALL items are also managed by the credited programs. Refer to TR00160-020 for a detailed discussion of the credited programs, particularly for the "Steam Generator Management Program" based on

Page 407: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 407 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

NEI 97-06 as incorporated into the Technical Specifications, in effectively managing aging during the period of extended operation and of meeting the intent of the pertinent GALL programs (XI.M19 and XI.M2).

SI SI Pipe and Fittings PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SI-j See Note A-SI-k

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SI SI Pipe and Fittings PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SI-j See Note A-SI-k

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Pipe and Fittings PB Carbon Steel Reactor Building

General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SI-e See Note A-SI-f

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SI SI Pipe and Fittings PB Carbon Steel Reactor Building

Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SI-e See Note A-SI-f

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item which has the same material, environment, aging effect and credited program. Additionally, the attributes of this program meet the intent of the

Page 408: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 408 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Valves (Body Only) PB Carbon Steel Sheltered General Corrosion Loss of Material Inspections for Mechanical Components

See Note A-SI-j See Note A-SI-k

V.E.1-b, V.E.1.1

T.2-10 Yes, plant specific No V.E.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

SI SI Valves (Body Only) PB Carbon Steel Sheltered Boric Acid Corrosion (Aggressive Chemical Attack)

Loss of Material Boric Acid Corrosion Surveillances

See Note A-SI-j See Note A-SI-k

V.E.1-a, V.E.1.1

T.2-17 No Yes V.E.1-a addresses external surfaces of carbon steel components. The material, environment, aging effect requiring management and credited program for this component/component type are consistent with the identified GALL item, which has the same material, environment, aging effect and credited program. Additionally, the attributes of this credited program meet the intent of the corresponding GALL Chapter XI program attributes. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation and in meeting the intent of the pertinent GALL program.

SI SI Pipe and Fittings PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-SI-g

N/A N.2-02 N/A N/A The material/environment (compressed gas) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

SP SP Tank (XTK0060), Sodium Hydroxide Storage

PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program; Above Ground Tank Inspection

See Note A-SP-g, See Note A-SP-h

VII.C2.4-a, VII.C2.4.1

N.2-05 No No VII.C2.4-a and VII.C2.4.1 address loss of material to a closed-cycle cooling water tank and shell, respectively. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effect/mechanisms, as clarified. The SP system is not a closed cycle cooling water system, although the environment and conditions in the NAOH addition portion of the system is closer to a treated water (such as

Page 409: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 409 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

found in closed-cycle cooling water) than the borated water environment of the majority of the system. Relative to the credited aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program and VCSNS credits the Chemistry Program, since the SP system is not a closed-cooling water system. Also, certain aging effects/mechanisms not addressed for the GALL item are also managed by the credited program. Additionally, the attributes of the credited Chemistry Program meet the intent of another GALL Chapter IX program (XI.M1) except as clarified. Refer to TR00160-020 for a detailed discussion of thew attributes of this program in effectively managing aging during thew period of extended operation and in meeting the intent of a pertinent GALL program. As detailed in the referenced notes, the Above Ground Tank Inspection, a one-time internal inspection not to be confused with GALL program XI.M29, "Above Ground Carbon Steel Tanks", an inspection of inaccessible areas of external tank surfaces, is credited with supplementing the Chemistry Program to detect and characterize the affects of aging due to general corrosion from lack of oxygen control. Refer to TR00160-020 for a detailed discussion of this activity.

SP SP Pipe and Fittings PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program; Above Ground Tank Inspection

See Note A-SP-g, See Note A-SP-h

VII.C2.1-a, VII.C2.1.1

N.2-05 No No GALL Item VII.C2.1-a, VII.C2.1.1, addresses loss of material for closed-cycle cooling water piping, fittings and flanges, respectively. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effect/mechanisms, as clarified. The SP system is not a closed cycle cooling water system, although the environment and conditions in the NAOH addition portion of the system is closer to a treated water (such as found in closed-cycle cooling water) than the borated water environment of the majority of the system. Relative to the credited aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program and VCSNS credits the Chemistry Program, since the SP system is not a closed-cooling water system. Also, certain aging effects/mechanisms not addressed for the GALL item are also managed by the credited program.

Page 410: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 410 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

Additionally, the attributes of the credited Chemistry Program meet the intent of another GALL Chapter IX program (XI.M1) except as clarified. Refer to TR00160-020 for a detailed discussion of thew attributes of this program in effectively managing aging during thew period of extended operation and in meeting the intent of a pertinent GALL program. As detailed in the referenced notes, the Above Ground Tank Inspection, a one-time internal inspection not to be confused with GALL program XI.M29, "Above Ground Carbon Steel Tanks", an inspection of inaccessible areas of external tank surfaces, is credited with supplementing the Chemistry Program to detect and characterize the affects of aging due to general corrosion from lack of oxygen control. Refer to TR00160-020 for a detailed discussion of this activity.

SP SP Valves (Body Only) PB Carbon Steel Treated Water

Crevice Corrosion, Galvanic Corrosion, General Corrosion, Pitting Corrosion

Loss of Material Chemistry Program; Above Ground Tank Inspection

See Note A-SP-g, See Note A-SP-h

VII.C2.2-a, VII.C2.2.1

N.2-05 No No VII.C2.2-a and VII.C2.2.1 address valves, and body and bonnet, respectively. The component/component type AMR results are consistent with the identified GALL item in material, environment, aging effect/mechanisms, as clarified. The SP system is not a closed cycle cooling water system, although the environment and conditions in the NAOH addition portion of the system is closer to a treated water (such as found in closed-cycle cooling water) than the borated water environment of the majority of the system. Relative to the credited aging management program, the identified GALL item references the Closed-Cycle Cooling Water System Program and VCSNS credits the Chemistry Program, since the SP system is not a closed-cooling water system. Also, certain aging effects/mechanisms not addressed for the GALL item are also managed by the credited program. Additionally, the attributes of the credited Chemistry Program meet the intent of another GALL Chapter IX program (XI.M1) except as clarified. Refer to TR00160-020 for a detailed discussion of thew attributes of this program in effectively managing aging during thew period of extended operation and in meeting the intent of a pertinent GALL program. As detailed in the referenced notes, the Above Ground Tank Inspection, a one-time internal inspection not to be confused with

Page 411: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 411 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

GALL program XI.M29, "Above Ground Carbon Steel Tanks", an inspection of inaccessible areas of external tank surfaces, is credited with supplementing the Chemistry Program to detect and characterize the affects of aging due to general corrosion from lack of oxygen control. Refer to TR00160-020 for a detailed discussion of this activity.

MS MS Pipe and Fittings PB Carbon Steel Ventilation * General Corrosion Loss of Material Preventive Maintenance Activities - Terry Turbine

See Note A-MS-m, See Note A-MS-n

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. Note that the ventilation* environment is ambient building air (i.e., sheltered environment) contained within the MS System components. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

MS MS Valves (Body Only) PB Carbon Steel Ventilation * General Corrosion Loss of Material Preventive Maintenance Activities - Terry Turbine

See Note A-MS-m, See Note A-MS-n

VIII.H.1-b, VIII.H.1.1

T.4-05 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment, and aging effect. Note that the ventilation* environment is ambient building air (i.e., sheltered environment) contained within the MS System components. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

FS FS Expansion Joint, Diesel Driven Fire Pump Exhaust

PB Carbon Steel Air-Gas (Dry) None Identified None Identified None Required See Note A-FS-q

VII.H2.4-a, VII.H2.4.2

N.3-10 Yes, plant specific No VII.H2.4-a addresses the Emergency Diesel Generator muffler. The component/component type AMR results are consistent with the identified GALL item in material and environment. However, for VCSNS, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

FS FS Pipe and Fittings PB Carbon Steel Air-Gas (CO2)

None Identified None Identified None Required See Note A-FS-q

N/A N.3-10 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Page 412: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 412 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

FS FS Expansion Joint, Diesel Driven Fire Pump Exhaust

PB Carbon Steel Yard Galvanic Corrosion, General Corrosion

Loss of Material Inspections for Mechanical Components

See Note A-FS-h

VIII.H.1-b, VIII.H.1.1

N.3-10 Yes, plant specific No VIII.H.1-b addresses external surfaces of carbon steel components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect, with the identification of additional aging effects requiring management that are not addressed in GALL for this item. However, the identified GALL item recommends plant specific evaluation of the credited program. Refer to TR00160-020 for a detailed discussion of the attributes of this activity in effectively managing aging during the period of extended operation.

RC RC Pipe and Fittings PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Notes A-RC-d and A-RC-f

V.C.1-b, V.C.1.1

N.1-14 Yes, Plant Specific No GALL Chapter IV, Reactor Coolant, addresses the treated water (non-borated) environment only on the secondary side of the steam generator. However, GALL item V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. VCSNS determined that the applicable containment penetrations were not subject to wetting by raw water and therefore not susceptible to MIC as described for this GALL item. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

RC RC Valves (Body Only) PB Stainless Steel Treated Water

Crevice Corrosion, Pitting Corrosion

Loss of Material Chemistry Program

See Notes A-RC-d and A-RC-f

V.C.1-b, V.C.1.2

N.1-14 Yes, Plant Specific No GALL Chapter IV, Reactor Coolant, addresses the treated water (non-borated) environment only on the secondary side of the steam generator. However, GALL item V.C.1-b addresses containment isolation components. The component/component type AMR results are consistent with the identified GALL item in material, environment and aging effect. However, the identified GALL item recommends plant specific evaluation of the credited program. VCSNS determined that the applicable containment penetrations were not subject to wetting by raw water and therefore not susceptible to MIC as described for this GALL item. Refer to TR00160-020 for a detailed discussion of the attributes of the credited program in effectively managing aging during the period of extended operation.

Page 413: Virgil C. Summer Nuclear Station Database AMR QueryV.C.1-a, V.C.1.2 T.2-03 Yes, plant specific No V.C.1-a addresses containment isolation components. The component/component type AMR

Virgil C. Summer Nuclear Station Database AMR Query

Page 413 of 413

Eval. Sys.

Act. Sys. Component Type Comp.

Func. Material Environment Age Mech Age Effect Age Program Age Notes GALL Section

SRP Item GALL Recom Site

Match Gall Discus

RC RC Pipe and Fittings PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-RC-g

N/A N.1-15 N/A N/A The material/environment (dry air) combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

RC RC Valves (Body Only) PB Stainless Steel Air-Gas None Identified None Identified None Required See Note A-RC-g

N/A N.1-15 N/A N/A The material/environment combination for this component/component type is not addressed for any item in GALL Chapters IV, V, VII or VIII. Also, no aging effects were determined to require management during the period of extended operation as detailed in the applicable note.

Comp. Func. FI - Filtration GR - Gas Removal HT - Heat Transfer NR - Noise Reduction

PB - Pressure Boundary SP - Spray Flow TH - Throttling WR - Water Removal