what’s next for rtu2020 & experion scada

36
What's Next for RTU2020 & Experion SCADA Paul Vellacott

Upload: honeywell-process-solutions

Post on 17-Aug-2015

144 views

Category:

Technology


16 download

TRANSCRIPT

What's Next for RTU2020 & Experion SCADA Paul Vellacott

3 © 2015 Honeywell International All Rights Reserved

Honeywell Solution Offering

End to End Solution

Experion PKS

Integrated with..

RTU2020 Ready-To-Use

RTU2020

Process Controller, I/O & EFM

Instruments, Camera, Radio,

FDAP….

4 © 2015 Honeywell International All Rights Reserved

Perfect Vision, 20/20 Vision with RTU2020

75º 70º

Honeywell RTU2020 Process Controller

5 © 2015 Honeywell International All Rights Reserved

The Physical Detail...

1. 24 Vdc Power Input 2. RS485 Ports (qty 2) 3. RS232 Ports(qty 2) 4. Ethernet Ports (qty 2)

5. Onboard I/O (qty 28) 6. SD Card Slot 7. Status LEDs 8. Expansion I/O

Connector

1 2

3

4

5

6

7

8

DIN Rail Mount

Honeywell RTU2020 Process Controller

8

R110

6 © 2015 Honeywell International All Rights Reserved

Perfect, 20/20 Vision with RTU2020

75º 70º

Harsh Environment Specifications

7 © 2015 Honeywell International All Rights Reserved

Harsh Environment Specifications

•-40ºC to 75ºC -40 to 167ºF

•Conformal Coating – G3

•Hazardous Locations ‒FM/CSA Class I Div 2 ‒ATEX Zone 2 ‒ IECEx Zone 2 75º

70º R110

8 © 2015 Honeywell International All Rights Reserved

Perfect, 20/20 Vision with RTU2020

HART enabled I/O Channels

9 © 2015 Honeywell International All Rights Reserved

RTU2020 I/O Modules

Mixed I/O, 28 channels

Mixed I/O, 28 channels

Mixed I/O, 28 channels

R110

10 © 2015 Honeywell International All Rights Reserved

Onboard with Controller or as Expansion I/O

28 Channels of Mixed I/O per Module

CPM IOM

R110

11 © 2015 Honeywell International All Rights Reserved

Using Expansion I/O Modules

1. Controller 2. I/O module 3. Right end plate 4. Left end plate

1 2

3

4 3

CAT 5

24Vdc

R110

12 © 2015 Honeywell International All Rights Reserved

Configuring Expansion I/O R110

IOMs Bound variable: complex data type

14 © 2015 Honeywell International All Rights Reserved

All Onboard: No Special Modules or Extra Hardware

FDM

Experion

HAR

T IP

HART

AI

AO

CMD48 CMD03

SV Logic

Common Alarm

PID

RTU2020 and HART

15 © 2015 Honeywell International All Rights Reserved

Perfect, 20/20 Vision with RTU2020

Efficient Wiring and Configuration

16 © 2015 Honeywell International All Rights Reserved

To change an RTU on-site

• Reduce exposure in hazardous environments

• Reduce production downtime

After

5 min

Before

45 min

Less Errors – Saves Time

Efficient Field Wiring & Cabinet Assembly

17 © 2015 Honeywell International All Rights Reserved

Efficient Configuration with RTU Builder

• IEC 61131-3 Programming ‒ Ladder Program ‒ Function block program ‒ Structured text ‒ Instruction List ‒ Sequential Function Chart

• Intuitive Work Flows • Online Diagnostics • Datalog Upload • Firmware Upgrades

‒ over slow networks

R110

18 © 2015 Honeywell International All Rights Reserved

Familiar Honeywell Algos R110

19 © 2015 Honeywell International All Rights Reserved

Intuitive RTU Builder R110

Task Driven Intuitive

User Interface

Multi version Firmware Support

20 © 2015 Honeywell International All Rights Reserved

Bulk Datalog Upload

Scripted bulk recovery of datalogs

R110

Alternative to DNP3 based history recovery

Remote recovery of

data

For use in external systems

21 © 2015 Honeywell International All Rights Reserved

Perfect, 20/20 Vision with RTU2020

Modern Processor

22 © 2015 Honeywell International All Rights Reserved

Modern Processor

Future Proof for Advanced Features

667 MHz Dual Core ARM® Cortex™-A9

Ready for ‒Wireless I/O ‒Redundant Controller

Other popular RTUs: ‒ 32 MHz Single core ‒ 256 MHz Single core ‒ 33 MHz Single core ‒ 150 MHz Single core

23 © 2015 Honeywell International All Rights Reserved

RTU2020 Wireless I/O

See a preview in the Knowledge Center

R120

Access Point

(FDAP)

… On board

24 © 2015 Honeywell International All Rights Reserved

Redundant Controller

Talk about it in the Knowledge Center

R120

25 © 2015 Honeywell International All Rights Reserved

Perfect, 20/20 Vision with RTU2020

Flow Calculations

26 © 2015 Honeywell International All Rights Reserved

Gas & Liquid Flow Calculations

Now verified to AER Directive 17

Standards Library Description

AGA

AGA 3 Orifice Meter

AGA 5 Volume to Energy Calculation

AGA 7 Turbine Meter

AGA 9 Ultrasonic Meter

AGA 8 Gas Compressibility

AGA 11 Coriolis Metering

API

API 11.1 Volume Correction Factors

API 11.2.2/M Compressibility Factors

API 11.2.4 Temperature Correction

API 11.2.5 Correction Factor for pressure

ISO ISO 6976 Natural gas: calorific value, density,

relative density and Wobbe Index

ISO 5167 Pressure differential devices such as orifice plates and venturis R110

27 © 2015 Honeywell International All Rights Reserved

Gas Meter Run

API 21.1 Compliant

R110

• RTU Builder 5 step ‘wizard’ ‒ Orifice ‒ Turbine ‒ Ultrasonic ‒ Coriolis

• 4 meter runs per RTU

28 © 2015 Honeywell International All Rights Reserved

Gas Meter Run

5 Step Wizard to Configure

R110

29 © 2015 Honeywell International All Rights Reserved

Meter Run Data via Enron Modbus

All API 21.1 Compliant

Meter Data Collection Status In Station

EFM Repository SCADA

Interface

Experion Server

Monitoring & Control

RTU2020 EFM

Experion Station

Gas Management

R430

30 © 2015 Honeywell International All Rights Reserved

HMI Design Alarm Management Distributed System Architecture

Virtualization Solutions Radically Simplified Configuration Superior Operator Experience

Experion SCADA

31 © 2015 Honeywell International All Rights Reserved

EFM Protocols with EFM Export Option

• EFM Protocols ‒ Enron Modbus ‒ Flow-X EFM ‒ Bristol Babcock EFM ‒ Omni ‒ Emerson ROC ‒ ABB TotalFlow

• Export to: ‒ FlowCal (CFX files) or ‒ CSV file

• Support for Gas & Liquids EFMs ‒ Gas: API 21.1 ‒ Liquids: API 21.2

One System to Collect All Data

SCADA Interface

Experion Server

Monitoring & Control

Electronic Flow Meter

Experion Station

Gas Management

EFM Repository

•Transaction records

•Audit Events

•Configuration

CFX / CSV export

Transaction record collection integrated into polling engine

32 © 2015 Honeywell International All Rights Reserved

• Multiple people working on the same server at the same time

• Up to 12 concurrent Users

• A ‘LEAP’ enabler

• Management of Change ‒ Logging and reporting of SCADA point

changes

Supports API 1168: Recommended Practice for Pipeline Control Room Management

Quick Builder Concurrent Users

33 © 2015 Honeywell International All Rights Reserved

• For custom displays ‒ HMI Web Display Builder ‒ New display repository Version control Check in, check out

• Supports API 1168:

Recommended Practice for Pipeline Control Room Management

Inbuilt Management of Change of the HMI

Display Builder MOC

34 © 2015 Honeywell International All Rights Reserved

User Defined Parameters

New types: “Scanned – Analog” “Scanned – Status”

Config for this parameter

Use case: Motor Status

Use case: Flag arrays

Use case: PLC PID Loop

35 © 2015 Honeywell International All Rights Reserved

PLC Configuration Options such as PID Tuning

User defined scanned

parameters on an Analog point

Example Use Case: PLC PID Loops

36 © 2015 Honeywell International All Rights Reserved

IEC 61850 SCADA Interface, update

• Enhanced Configuration ‒ History & Trend config ‒ Import/Export bulk build ‒ IED cloning bulk build

• Alarm and SOE on same point

• Selective Report Enable • Field Timestamp on events

• Q3 2015 update:

‒ Edition 2 support ‒ Single Line Diagrams from

SCD files ‒ Experion PRP driver

Protection Relay TMU

Intelligent breaker

Clone

R431

37 © 2015 Honeywell International All Rights Reserved

HMI Design Alarm Management Distributed System Architecture

Virtualization Solutions Radically Simplified Configuration Superior Operator Experience

Experion SCADA

38 © 2015 Honeywell International All Rights Reserved

www.honeywellprocess.com