Advantages
Highly conductive earth-pit backfill
Reduces soil resistivity by upto 90%
Non-corrosive
Independent of ambient moisture content, hence works in all weather conditions
Compatible with all types of earthing electrodes, be it pipes, plates or rods of any metal
Can also be used in trenches made for horizontal type earthing systems
Advanced Earthing Compound
EARTH WELLADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM
ADVANCED EARTHING COMPOUND
Net Wt. 25 Kgs.
ADVANCED EARTHING COMPOUND
EARTH WELLADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM
Net Wt. 25 Kgs.
Increases the total surface area of the earthing electrode ensuring quick dissipation of fault currents
Maintains constant volume regardless of moisture content
Earthwell Earthing Compound doesn't shrink or expand. It maintains constant contact with electrode and surrounding soil
Long shelf life; can be stored for very long periods without deterioration
Environmental friendly; does not pollute or contaminate the water table
GI Plate Earthing
Plate Earthing
Copper Plate Earthing
Features
The earth connection can be provided with the
help of a copper/G.I. plate. When G.I. plate is used
it should not be of less than 60 cm x 60 cm x 6.35
mm.
The plate is kept with its face vertical at a depth of
3 m and is so arranged that it is embedded in an
alternate layer of coke and salt for a minimum
thickness of about 15 cm in case earthing is done
by copper plate and in coke layer of 15 cm if it is
done with GL Plate- The earth wire is securely
bolted t0 the earth plate with the help of bolt nut
and washer.
Pipe Earthing
(I) The earthing electrode should be situated at a place at least
1½ metre away from (i.e. outside) the building whose
installation system is being earthen.
(ii) The earth wire should be of same material as that of earth
electrode.
(iii) The minimum sectional area of the earth lead wire should
never be less than 0.02 sq. inch (No. 8 S.W.G.) and not
more than 0.1 sq. inch (i.e. 7.036 S.W.G.).
(iv) The size of earth conductor as a general rule should not be
less than half of the section of live line conductor.
(V) The size of the continuous earth wires used with cables
should not be either less than 0.0045 sq. in (14 S.W.G.) or
half of the installation conductor
Pipe Earthing Features:
Low electrical resistance and high corrosion resistance
Connectivity up to chamber or earth terminals
Reliable, durable and easy to handle
Highly secure and well tested by using latest technology
Optimum quality performance and available in different sizes
GI Pipe Earthing ElectrodeModel Length Pipe Dia
(mm) (mm)
EWIT-140GIP 1000 40
EWIT-240GIP 2000 40
EWIT-250GIP 2000 50
EWIT-340GIP 3000 40
EWIT-350GIP 3000 50
Our company manufactures and supplies a comprehensive range of Cast Iron Pipe
Earthing to our clients. This hi tech equipment is widely used in IT software
companies, telecommunication towers, oil refineries, pumping stations, lightning
protection systems, power generators, etc. These devices, crafted using high
quality raw materials, are tested on stiff quality grounds for ensuring better results.
Features
Anti corrosive
Convenient to install
Highly conductive
Safe and reliable
CI Pipe Earthing
Specifications
Size: 75 mm TO 150 mm
Thickness: 3.5 mm TO 13 mm
Length: 3 mtr.
Material: Grey Cast Iron
Carbon: 3.5% TO 3.8%
Manganese: 3.5% TO 5%
Phosphors: 0.12% to 0.2%
GI Pipe Earthing CI Pipe Earthing
Available in 25 & 10 Kgs Bag
MODEL Length Rod Dia Rod Dia
(mm) (mm) (inches)
EWIT-CB614 2000 14.2 5/8”
EWIT-CB1014 3000 14.2 5/8”
EWIT-CB617 2000 17.2 3/4”
EWIT-CB1017 3000 17.2 3/4”
B
A
C
Description Material ABC Dimensions mm Weight Each
Concrete Inspection Concrete with Stainless 320 x 320 x 192 30 Kg.
Pit Steel Lifting Hook
Bentonite Moisture Retaining Compound
Lightning Protection System (Franklin Rod)
Copper Earthing RodsTripoleCopper Bonded
Earthing Rods
HIGH TENSIL LOW CARBON STEEL
MOLECULARLY BONDED 99.9% PURE ELECTROLYTIC COPPER
Lightning Arrester (ESE Terminal)Advantages
The area to be protected is a dangerous
area, lightning conductor can be installed
outside
Possible to protect several buildings with
the same lightning conductor Economic
Possible to protect a structure and its
surrounding environment at the same time
Protection of open zones
Can be integrated seamlessly and discreetly
into the building struck
These Principle
Experiments are described which are designed to test two devices based on
the ‘early streamer emission’ (ESE) principle, for lightning protection, against
the traditional Franklin rod. In all three cases, the device was subjected to a
steady negative electric field from a sphere, simulating the field beneath a
thundercloud, prior to application of a superimposed negative impulse field,
simulating the field due to the downward leader. The first device consisted of
a vertical rod to which a subsidiary 1/50 s positive impulse voltage, variable
up to 40 kV peak, could be applied with varying delays from the start of the
negative impulse field. Energising of the rod was thus independent of the
applied negative field. The second device was a commercial product,
energising of which was controlled by its own power supply. Sparkover
voltages in the sphere/device gaps and times to breakdown were measured.
It is shown that the ESE devices showed a small advantage, in time to
breakdown, over the Franklin rod
Multiple Point Air Terminal
Model Length Rod Dia Sphere Size Material
(MM)
EWIT – FR 60 1200 25.4 60 COPPER
EWIT – FR 80 1200 25.4 80 COPPER
EWIT – FR 100 1200 25.4 100 COPPER
Range of Radius Protection50 mtrs, 65 mtrs, 90 mtrs
and 108 mtrs.
ESCOLTRIX
Advanced Earthing Electrodes
Plot No. 101, 1st Floor, KPHB Colony, Road No.4, Kukatpally, Hyderabad - 500 072, Telangana, India.Tel : 040-40274011 Mob: 92460 67549, 80746 67946
Email: info@earthwel.com Website: www.earthwel.com
EARTH WELLADVANCED EARTHING & LIGHTNING PROTECTION SYSTEM
Fu
xion: 66668789
Strip in Pipe Pipe in Pipe
CUGI GI
GI
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
EARTH
WELL
AD
VAN
CED
EA
RTH
ING
& L
IGH
TNIN
G P
RO
TEC
TIO
N S
YSTE
M
GI Pipe GI Strip ELectrode
Model Length Pipe Dia Strip Size (mm) (mm) (mm)
EWIT-150G 1000 50 40 x 6 x 1100
EWIT-180G 1000 80 50 x 6 x 1100
EWIT-250G 2000 50 40 x 6 x 2100
EWIT-280G 2000 80 50 x 6 x 2100
EWIT-350G 3000 50 40 x 6 x 3100
EWIT-380G 3000 80 50 x 6 x 3100
GI Pipe in Pipe Electrodes
Model Length Pipe Dia Inner pipe Strip Size (mm) (mm) (mm) (mm)
EWIT-250G 2000 50 40 30 x 6
EWIT-280G 2000 80 50 40 x 6
EWIT-350G 3000 50 40 30 x 6
EWIT-380G 3000 80 50 40 x 6
Copper Strip GI/CU Electrodes
Model Length Pipe Dia Pipe Type Strip Size (mm) (mm) (mm)
EWIT-150GC 1000 50 GI 40 x 6 x 1100
EWIT-250GC/CC 2000 50 GI/CU 40 x 6 x 2100
EWIT-280GC/CC 2000 80 GI/CU 50 x 6 x 2100
EWIT-350GC/CC 3000 50 GI/CU 40 x 6 x 3100
EWIT-380GC/CC 3000 80 GI/CU 50 x 6 x 3100
Copper Bonded ELectrode
Model Length Pipe Dia Strip Size (mm) (mm) (mm)
EWIT-150CB 1000 50 40 x 6 x 1100
EWIT-180CB 1000 80 50 x 6 x 1100
EWIT-250CB 2000 50 40 x 6 x 2100
EWIT-280CB 2000 80 50 x 6 x 2100
EWIT-350CB 3000 50 40 x 6 x 3100
EWIT-380CB 3000 80 50 x 6 x 3100
'EARTHWELL Advanced Earthing Electrode is a combination of specially developed
“Earthing Electrode” and “BACK FILL COMPOUND”.
A revolutionary corrosion free grounding system provides high-tech and noise free
earthing for electrical, electronics, communication, data (digital & analog) and
lightning systems
Earthing System
A Maintenance free Earthing System
· Long and reliable average life of 15 Plus years
· Maintenance Free
· High Cost savings on maintenance and replacement over 15 Plus years
· Very Smooth dissipation of fault, lightning and short circuit currents
· Low electrical resistance to earth
· High Resistance to corrosion
· Repeated current carrying capacity and continuity Control
· Ideal earthing system for electric/sensitive electronic appliances, equipment and
machinery
· Safety of life and property from earth related electrical hazards