atms (sdbot)

21
Page 1 of  21 User Requirement Specifications for Advanced Traffic Management System Equipments 1. CCTV Cameras The Closed Circuit Television (CCTV)  Surveillance shall comprise video camera,  its housing and pan, and Tilt Heads.  The video camera shall be mounted at a height so as to cover the target length of  highway and the housing shall be able to withstand adverse weather conditions.  It shall have a 360 degree angular travel in the horizontal  plane and a tilt of  90 degrees down from 0 degrees horizontal.  It shall have zoom lens with minimum power of  30 X, auto iris and infrared filter, infrared compatibility  for night operation and remotely selectable operating modes.  It shall have compatibility with coaxial cable/optical  fibre cable. The CCTV camera shall have the following minimum features / capabilities:  1. Suitable design to provide absolute PTZ performance and extreme weather operability 2. Ruggedized vandal proof  housing to deliver performance  in harsh conditions,  3. Viewing range of  1 km radius,  4. Tilt Range of  90° down from  Horizontal  & 360° angular travel in the horizontal  plane. 5. Daynight IR filter for brilliant daytime colour and excellent night vision under low light and infrared illumination 6. Total zoom 300X (30X optical, 10X digital)  7. Closed loop speed control  with Integral pan / tilt motor drive to enable smooth,  precise pantilt for fine control  and accurate tracking,  even at high zoom levels 8. Flat glass window with wiper and internal heater for better optical  performance in rainy, humid environments  9. Waterproof,  weathersealed and corrosion resistant 10. Image Sensor: 1/4” colour CCD 11. Horizontal  Resolution:  525 TV lines 12. Sensitivity:  0.01 Lux or suitable for highway application in night 13. Resolution:  NTSC / PAL 14. Minimum Illumination 0.7 Lux @ F1.4 | Zero Lux under IR illumination 15. Focus system: Auto and manual focus 16. Communication  RS485 / RS422 17. Base Mounting  options 18. The complete field camera unit shall be IP66 rated 19. 1 Channel Video Server 

Upload: aniruddh-kanade

Post on 04-Jun-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 1/21

Page 1 of  21 

User Requirement Specifications for Advanced Traffic Management System Equipments 

1. CCTV Cameras The

 Closed

 Circuit

 Television

 (CCTV)

 Surveillance

 shall

 comprise

 video

 camera,

 its

 housing

 and

 

pan, and Tilt Heads. The video camera shall be mounted at a height so as to cover the target 

length of  highway and  the housing  shall be able  to withstand adverse weather conditions.  It 

shall have a 360 degree angular  travel  in  the horizontal plane and a  tilt of  90 degrees down 

from 0 degrees horizontal. It shall have zoom  lens with minimum power of  30 X, auto  iris and 

infrared  filter,  infrared  compatibility  for  night  operation  and  remotely  selectable  operating 

modes. It shall have compatibility with co‐axial cable/optical fibre cable. 

The CCTV camera shall have the following minimum features / capabilities: 

1.  Suitable design

 to

 provide

 absolute

 PTZ

 performance

 and

 extreme

 weather

 operability

 

2.  Ruggedized vandal‐proof  housing to deliver performance in harsh conditions, 

3.  Viewing range of  1 km radius, 

4.  Tilt Range of   90° down from 0° Horizontal & 360° angular travel in the horizontal plane. 

5.  Day‐night IR filter for brilliant daytime colour and excellent night vision under low light 

and infrared illumination 

6.  Total zoom 300X (30X optical, 10X digital) 

7.  Closed loop speed control with Integral pan / tilt motor drive to enable smooth, precise 

pan‐tilt

 for

 fine

 control

 and

 accurate

 tracking,

 even

 at

 high

 zoom

 levels

 

8.  Flat glass window with wiper and internal heater for better optical performance in rainy, 

humid environments 

9.  Waterproof, weather‐sealed and corrosion resistant 

10. Image Sensor: 1/4” colour CCD 

11. Horizontal Resolution: 525 TV lines 

12. Sensitivity: 0.01 Lux or suitable for highway application in night 

13. Resolution: NTSC / PAL 

14. Minimum

 

Illumination 

0.7 

Lux 

F1.4 

Zero 

Lux 

under 

IR 

illumination 

15. Focus system: Auto and manual focus 

16. Communication RS485 / RS422 

17. Base Mounting options 

18. The complete field camera unit shall be IP66 rated 

19. 1 Channel Video Server 

Page 2: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 2/21

Page 2 of  21 

20. Network Video Recorder with 6 TB storage 

21. Pole and mounting 

a. GUI (Graphical User Interface) The CCT  ‐ GUI enables  the  field camera units  to be managed by  the operator efficiently and 

effectively. The same GUI also provides the supervisory control and management report facility. 

The GUI shall be divided into two screen areas: 

1.  Video feeds 

2.  Event Status area 

The size, shape and location of  the two screen areas shall be adjustable. 

The labeling of  locations of  the field camera unit is programmable at system installation stage, 

during system

 commissioning.

 The

 locations

 can

 have

 a specific

 name

 relating

 to

 their

 area.

 

b. Function The CCT for CCTV system must operate in accordance to the following requirements: 

1.  Display the events that are logged on a continuous basis 

2.  All data and general alarm conditions must be logged to a database. 

3.  Database must have query facilities 

4.  Storage capacity for all alarm messages, three (3) years at any point in time 

5.  Storage capacity for video information, with 6 TB storage. 6.  The CCTV‐CCT  should 

on a regular basis, log event of  any problem for each individual field camera unit in the 

CCT as an event log. 

2. VMS SPECIFICATIONS (HARDWARE) The design for the Variable Message Signs (VMS) will be modular with sign panels using LEDs I High

‐Gain

 Trans

‐Reflective

 LCDs

 for

 outdoor

 ambient

 lights.

 The

 sign

 panel

 should

 be

 such

 that

 

a display is legible from a distance of  about 200 m. For this purpose, panels shall have minimum 

dimensions of  3m  length x 1.8 m depth. The minimum height of   the characters  shall be 300 

mm. The contrast ratio shall be more than 30 perpendicular to the bold face and more than 10 

at an angle of  ± 70 degrees  to  the perpendicular. The equipment  shall be capable of   storing 

minimum 10 frames that can be triggered on receiving the tele‐command. The sign panels shall 

be  installed  on  the  structure  in  such  a manner  that  they  are  aesthetically  pleasing  and  can 

Page 3: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 3/21

Page 3 of  21 

withstand wind pressures.  The  equipment  shall be  capable of   storing minimum  semi‐duplex 

mode and other known forces. The minimum vertical clearance available at VMSs shall be 6.0 m 

from the road surface. Power supply shall be fed from the integrator locations. Gantry  “T”  Type  for  both  side  VMS  board  (text  +  Graphics)  detailed specifications Parameters  Details 

Dimensions  1800(H)X 3000(W)X225(D) mm (Display Area‐Full 

Matrix, 

Housing    Enclosure: AlMg3/MS plate 3 mm thickness 

  Front plate: AlMg3/MS plate 3 mm thickness 

  Housing coating: electrostatic powder coating 

(based on

 polyester)

 

  Front panel coating: low reflection black matt 

paint 

  Service doors: AlMg3/MS plate 2 mm 

thickness; 

  Locking system: quarter turn locking system 

  Earthing : Eathing with Copper Strip 

Protection level  IP55 (minimum) 

Weather Proofing: CENELEC EN 60529: 1991: Degrees 

of  protection provided by enclosure (IP code) (IEC 529: 

1989). 

All 

enclosures 

exposed 

to 

the 

elements 

shall 

be 

protected to IP65 in terms of  this standard 

Display area  Text area: Pitch: 25mm 

‐ Resolution: 56 (H) X 128(W) Pixels 

‐ Display Area: 1800 x 3000 mm 

‐ Character Size: 14 X 7 font = 350 x 175mm, 16 

characters/line x 3 lines/Frame

 

‐ Can display text & graphics & animations 

‐ Color: Amber 

Page 4: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 4/21

Page 4 of  21 

VMS display area: ‐ Pitch: 25mm (basic module is 8x16 pixels) 

‐ Resolution: 72 (H) X 48(W) Pixels 

‐ Display Area: 1800 x 1200mm 

‐ Can display text & graphics & animations 

‐ Color: Amber 

Support for multi‐languages  User defined fonts, English, Hindi 

Operating Modes  Central Control System and Local Computer 

Message Storage    Up to 10 messages of  30 characters length in 

the local system memory. 

  Up to 10 pictogram in the local system 

memory 

Controller Addressing  It shall be possible to change the address of  all type 

of  VMS through software only 

Different messages shall be displayed separately on 

both sides. 

Message Display  The messages shall be sent / triggered to be 

displayed through

 one

 of 

 the

 following

 

methods: 

  Download through Control Centre computer 

  By receiving command to display locally 

stored text and graphics from Control Centre 

computer 

  Download through local computer (lap top) 

  Receiving command to display locally stored 

text and graphics from local computer (lap 

top) 

Communication Interface  RS232 & RS485 & Ethernet 

Communication Protocol  CIP, TLS or DGT 

Receiving Input    Accepting messages for display or store in 

Memory 

Page 5: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 5/21

Page 5 of  21 

  Writing any messages at an effective rate of  

60 characters / second 

  Blanking of  complete sign 

Display Driver  Display driver shall be capable of  driving 3 lines of  

10 characters

 each

 and

 a pictogram

 with

 at

 least

 

90% uniform brightness level throughout the board 

Responses to input  The VMS controller shall acknowledge after 

receiving any input from control room / local 

computer 

Service Port  Local in VMS 

Wireless port  Bluetooth interface on VMS 

Intensity regulation

 0‐100%

 continuous

 

LED aging compensation  Automatic LED current increase over product life to 

maintain desired brightness 

Power Supply  AC 230 (‐15%...+10%) 50Hz 

Power Consumption  About 1200 W 

Standards  Should comply EN 12966:2005 

Light intensity  L2 minimum 

Color  C2 

Beam Width  B2 

Luminance at angles ±7º horizontally and ‐5º 

vertically 

minimum 50 % of  zero angle intensity 

Contrast Ratio  The contrast ratio shall be more than 30 

perpendicular to

 the

 bold

 face

 and

 more

 than

 10

 at

 

an angle of  ± 70 degrees to the perpendicular. 

Visibility  The sign panel should be such that a display is 

legible clearly from a distance of  about 200 m even 

in foggy condition. 

Page 6: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 6/21

Page 6 of  21 

LED type  5 mm ultra bright LED’s 

Optical properties  According to EN 12966:2005 

L3(T)(*), R2‐R3, C2, B1‐B7 

LED  Test Option to glow all LED at a time for testing of  

any LED

 failure

 

LED Failure Detection  Should be able to test failure of  each LED, minimum 

3 times a day. 

LED makes  CREE, Osram, Nichia, Avago‐US 

Background and UV Resistance  The display background shall be non‐reflective and 

the display shall be U.V. resistant 

Wind Pressure  Should be able to withstand wind pressures from 

gusts of 

 up

 to

 150

 km

 per

 hour

 

Tamper Indicator  Due to the fact that the equipment is mounted in 

the open, it may be subjected to vandalism. A 

tamper switch with adjustable sensitivity should be 

fitted in each VMS 

Ambient temperature range  T1, T2, T3 (‐40º C to +60º C ) 

Product Life Time  10 years minimum 

Approved Makes  Ortana/Telegra/Imago/ATT 

Functional Specifications Parameter Default  Value Other  Possibilities 

Picture that will be 

displayed after VMS 

RESET 

VMS will be off   – blank 

picture 

1. Any of  programmed 

Pictures 

2. Last displayed picture 

Picture that will be 

displayed in case of  

communication failure with 

control device 

(e.g. Roadside Cabinet) 

VMS will be off   – blank 

picture 

1. Any of  programmed 

Pictures 

2. No reaction 

Page 7: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 7/21

Page 7 of  21 

VMS state in case of  

communication loss 

between one or more driver 

modules and controller 

module 

VMS will be off   – blank 

picture 

VMS will stay ON 

Period of  time after which 

VMS will set defined picture 

in case of  communication 

failure 

Max. 3 minutes  Any value from 10 sec. to 

several hours (Max. 9 

hours.) 

VMS GUI The  CCT  ‐ GUI  enables  the  remote  VMSs  to  be  managed  by  the  operator  efficiently  and 

effectively. The same GUI also provides the supervisory control and management report facility. 

The GUI

 shall

 be

 divided

 into

 three

 screen

 areas:

 

  Command bar 

  Map area 

  Event status area 

The size, shape and location of  the two screen areas shall be adjustable. 

The labelling of  zones and the VMS units are programmable at system installation stage, during 

system commissioning. The zones can have a specific name relating to their area and VMSs can 

be identified

 using

 alphanumeric

 codes.

 

VMS GUI Functions The CCT (ATMS SCADA) for VMSs operates in accordance to the following requirements: 

  The solution shall be configurable by customer, i.e. addition/deletion of  VMS, changing 

location of  VMS, importing/modifying pictograms, multi‐languages. 

  The  solution  should  provide  quick  customization.  Any  Change  Request  should  be 

implemented 

in 

10 

days 

from 

the 

date 

of  

Change 

Request 

Document. 

  Operation via the CCT keyboard. 

  Change of  display message of  VMS and group of  VMS. 

  Entering the reason of  changing display to non‐standard (non pre‐set) text message, or 

symbol and why that was necessary. 

  Once the VMS message is changed, it shall be indicated at the VMS‐CCT on the Graphical 

User Interface (GUI) display, with the VMS icon changing its colour. 

Page 8: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 8/21

Page 8 of  21 

  The date and time of  message change shall be registered on the VMS‐CCT 

  Database must have exhaustive query facilities. 

  Storage capacity for maintaining all event and incidents shall be a minimum of  three (3) 

years at any point in time. 

 The

 

VMS‐

CCT 

should 

on 

regular 

basis 

test 

each 

individual 

VMSs 

exhaustively 

to 

test 

for 

correct  operation.  In  the  event  of   any  problem,  it  shall  be  reported  by  the  CCT 

accompanied by an event log and the colour of  faulty VMS to be changed to red. 

  Option to glow / blanking of  all LED at a time for testing of  any LED failure. 

VMS Road User requirements The VMS shall provide an alphanumeric or graphical pattern or both display to the road user, 

visible from a distance of  approximately 200 metres (even in foggy condition). Messages can be 

displayed in the form of  an alphanumeric sequence, consisting of  three lines of  Hindi or English 

characters and / or graphics. 

VMS Security The VMS shall contain access door open detector switch sensor at all  its doors. When any of  

these sensors detects activity, a local audible alarm shall sound in the nearby Sub‐centre and a 

message alarm shall be sent to the VMS‐CCT  in the control room to alert the Central Control 

Room operator about suspected tampering. 

Locking arrangement shall  require a special tool to access electronic compartment of  VMS.  It 

shall not be possible to normally open (without any damage to the enclosure) the VMS cabinet 

without this special tool. 

3 Emergency Call Box (ECB) Emergency  call  boxes  (ECBs)  with  loud  speaker,  micro  phone,  activation  button  with  LED 

indicating  conversation,  shall be housed  in  a  vandal proof   casing  and operate  in  full  to play 

mode in noise level of  up to 95 decibels within built diagnostic features for automatic detection 

in case of  damage by any object. 

ECB Master Unit The Master ECB structure shall consist of  a lockable door for accessing the following: 

  the loud‐speaker, 

  the microphone, 

  the push‐button (built in with the structure), 

  LED indicator, 

  the processing electronics, 

  the battery pack with 48 hours back up (Mounted at the top of  the ECB post with lock & 

key arrangement) 

Page 9: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 9/21

Page 9 of  21 

  the solar panel to meet the power requirement of  the complete ECB unit supplying the 

electronics, (shall be mounted at least 3.5 m above bottom level of  ECB post) and 

  the termination assembly to connect to the Slave ECB unit. 

ECB Slave Unit The Slave ECB structure shall consist of  a lockable door for accessing the following: 

  the loud‐speaker, 

  the microphone, 

  the push‐button (built in with the structure), 

  LED indicator, and 

  the termination assembly to connect to the Master ECB unit. 

ECB Housing The

 housing

 shall

 be

 yellow

 colour

 powder

 coated

 Mild

 steel.

 Colour

 of 

 the

 ECB

 housing

 shall

 be

 

chosen such that it shall match to the housing and is prominent and easily recognizable by the 

users. 

ECB Redundancy Scheme   Redundancy shall be maintained in such a manner that a single fiber core / copper cable 

failure or single ECB unit failure shall not affect the normal operation of  the other ECB 

units and Control Room functionality. 

  In  case of   since ECB  failure,  it  should not affect  the  functionality and communication 

with CCT for other ECBs. 

ECB Technical Specifications a) Speaker   Type Water resistant 

  Max Power 15W 

  Impedance 8 ohm ±15% 

  Bandwidth: 40

 Hz

 to

 8 KHz

 

  ECB interface output Power: 0 to 6 W 

b) Microphone   Type Dynamic microphone 

  Sensitivity: 1.9 mV +/‐3dB /Pa 

Page 10: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 10/21

Page 10 of  21 

  Impedance 200 ohms 

  Input level at ECB interface: ‐20 to ‐50 dBm 

c) Environmental Specifications  

Waterproof  

box 

for 

underground 

cabinet: 

proof  

level 

IP 

67 

  Weather resistant to IP67 standard 

  Operating temperature: ‐ 10 to + 60°C 

  Lightening protection to ITU‐T recommendation K.21 

  Relative humidity: 10%~75%(non condensing) 

  Maximum wind speed: 150 km/h 

d) EMC standards:   EN

 50081

‐1 EN

 50081

‐2 

  EN 50082‐1 EN 50082‐2 

  EN 55022 

4. MET SPECIFICATIONS The  meteorological  sensors  shall  comprise  thermocouple  /pyrometer,  humidity  meter, 

anemometer, visibility meter and  sensor  for measuring pavement  surface  temperature. They 

shall be  installed on a single pole with a specific attachment and power  supply  fed  from  the 

integrator. They

 shall

 have

 the

 facility

 to

 communicate

 on

 Polythene

 Insulated

 Jelly

 Filled

 

copper cables (PIJF) /Optical Fibre Cable. 

MET System Configuration MET system shall consist of  the following weather sensors and components; 

1  Ambient temperature sensor + 0.3° C 

2  Wind Speed & Direction sensor + 1.0 m/s 

3  Road Surface temperature sensor + 0.2° C 

Relative Humidity

 sensor

 

5  Visibility sensor + 15% 

6  Data logger 

7  Solar panel & Battery 

8  NEMA‐4 Enclosure & mast accessories 

Page 11: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 11/21

Page 11 of  21 

9  Cable and accessories required in control centre 

10 The system shall be installed on single steady G.I. pipe without use of  stay/guy cables. 

11 Chainlink fencing (2.5 m height) along with anti‐intrusion barbed wire coils mounted on 

top shall be provided with entry gate. 

MET Ambient temperature sensor The  temperature  sensor  shall  incorporate  thermo‐linear  network  consisting  of   resistors  and 

precise  thermistors which  shall produce  an output  voltage  linear with  the  temperature. The 

thermistor network shall be embedded in a tube with cooling ribs. The sensor shall be equipped 

with a radiation screen that shall hinder heating of  the sensor by direct sunshine. 

The sensor can be used outside the specified temperature range with reduced accuracy. 

MET Wind Speed & Direction sensor The wind speed sensor shall have a three cups helicoids propeller and the wind direction sensor 

shall be  rugged  lightweight  vane with  a  sufficient  low  aspect  ratio  to  assure good  fidelity  in 

fluctuating wind conditions. 

Wind  speed  shall  be  measured  by  AC  sine  wave  voltage  signal  with  frequency  which  is 

produced due to rotation of  propeller, which is directly proportional to the wind speed. 

Wind direction sensor’s vane angle shall be sensed by a precision potentiometer housed in a 

sealed chamber. With a known applied voltage to the potentiometer, the out put voltage shall 

be directly proportional to the vane angle. 

The instrument shall be made of  UV stabilized plastic with stainless steel and aluminum fittings. 

Precision grade, stainless steel ball bearing shall be used. 

A  mounting  orientation  ring  shall  be  available  to  assure  correct  realignment  of   the  wind 

direction reference when the instrument is removed for maintenance. 

MET Road Surface temperature sensor The sensor must be installed flush with the road surface and outside the wheel path where the 

water will not accumulate. The sensor shall be worn down with the surrounding road surface 

and shall be powered by the data logger. 

Page 12: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 12/21

Page 12 of  21 

MET Relative Humidity sensor The  humidity  sensor  circuit  shall  have  a  linear  output  voltage  between  0  to  100%  relative 

humidity. 

MET Visibility measurement sensor It shall measure atmospheric visibility by determining the amount of  light scattered by particles 

(smoke, dust, fog, rain and snow etc.) in the air that passes through the sample volume. 

MET Data logger The Data logger and software shall provide the following minimum functions: 

1.  The Data logger shall have the facility to communicate on Optical fiber cable. 

2.  It shall be compact, rugged in design and having ease of  maintenance 

3.  It shall be capable of  detecting and keeping track of  the various climatic parameters on 

the highway and initiate appropriate alarms at the Control Centre. 

4.  Perform weather data collection, data storage and transfer to control centre. 

5.  Insert sequence numbers for each data records. 

6.  The  Data  logger  shall  be  of   modular  design  to  aid  in  system  maintenance, 

troubleshooting and

 in

‐field

 servicing.

 

7.  All components of  the Data  logger,  including sensors, shall contain necessary electrical 

protection to prevent damage from electrical surges, spikes and the effects of  lightning. 

8.  The  Data  logger  shall  be  of   durable,  industrial  design  and  construction  and  enable 

continuous  operation,  with  automated  start‐up  in  the  event  of   power  outage  and 

restoration. 

9.  All sensor and ancillary equipment connections shall be conveniently located in the Data 

logger front panel. All connections, where possible, shall be plug‐in, quick connect style. 

10. All AC power connections shall be shielded to prevent electrical shock. 

11. LED status indicator for correct / faulty operation of  Data logger, with different colours. 

12. Communication 

a.  On‐board Ethernet interface 

b.  Two RS‐232 interface 

13. Storage 

Page 13: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 13/21

Page 13 of  21 

a.  Non‐volatile  local  storage  to  prevent  data  loss  during  power  outages  preferably 

based on flash memory. 

14. Enclosure 

a.  IP 66 rated 

b.  Powder coated 

5. ATCC SPECIFICATIONS (TECHNICAL) The Automatic Traffic Counter‐cum‐Classifier (ATCC) shall be capable of  detecting and recording 

all, categories of  vehicles plying on the Project Highway (Six lane) based on their length and no. 

of  axles. The system shall be robust and capable of  operating with minimum maintenance and 

may be either piezo‐electric or  infrared.  It  should have minimum accuracy  level of  99%. The 

logic  units  shall  be  microprocessor  based.  The  system  should  be  able  to  record  and  store 

vehicle 

data 

for 

period 

of  

at 

least 

two 

weeks 

with 

Daily 

Traffic 

Volume 

of  

up 

to 

1,00,000 

vehicles. The system shall have compatibility to transfer the data on PIJF/Optical Fibre Cable/ by 

using  any  of   the  available  communication  mode  like  GSM  (Global  System  '  for  Mobile 

Communications) / GPRS (General Packet Radio Service), landline modem, CDMA (Code Division 

Multiple Access) depending upon the effective and economic operation of  the particular mode 

available at  the  site. The  system  shall be electric/solar power operated depending upon  the 

availability of  source. The ATCC system shall consist of  a piezo‐loop‐piezo configuration in a traffic lane, with a square 

or rectangular loop to ensure proper coverage of  the lane width systematically placed between 

the piezo

 sensors.

 

Supplier shall propose any other configuration, if  required, for better results. 

ATCC Features   Active lightning protection. 

  Flexible configuration. 

  Digital chassis height detection. 

  Coincidence detection (lane straddle).   Tidal flow and reverse direction recording.   Comprehensive system performance monitoring. 

  Detail sensor diagnostics capability. 

  User‐friendly set‐up and complete diagnostics. 

Page 14: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 14/21

Page 14 of  21 

  Provision for most popular data formats. 

  User‐modifiable parameter sets. 

  Comprehensive software support. 

  Low power consumption (solar charging supported). 

ATCC Components The ATCC System shall consist of  the following system components: 

A.  Piezo Sensors for axle counting (Class II 6' BL Piezo Sensor w/100' Lead In) 

B.  Vehicle Detector Loop 

C.  ATCC Controller and its enclosure 

D. 

In‐

built 

Power 

backup 

E.  VEHICLE TRAFFIC CLASSIFIER up to 6 Lanes Consisting of  Road side Electronics‐Microprocessor 

based, Complete 1 MB memory, which is suitable for our surveys. 16 Key watertight Keyboard 

and display, with input for inductive Loop Sensors with field 

F.  UPP 9 Pin Serial Cable‐6' 

G.  PU200/S PIEZO INSTALLATION RESIN 

H.  UPP Power Supply AC/DC 

I.  Centurion Standard Software (Windows based)OR equivalent 

J.  Work Station for ATCC 

K.  UPP LNPC Loop Cable 

L.  Loop Cable with Loop Filler 

M.  Miscellaneous items required in Installation 

ATCC Axle counter The axle counting  sensors  shall consist of   two  independent Piezoelectric Sensors of  different 

length across a travel lane, enabling detection of  axles of  all vehicle categories. 

Two piezo

 sensors

 with

 difference

 in

 lengths

 by

 1:2

 ratio

 shall

 be

 installed

 in

 opposite

 

arrangement to  its previous or next piezo sensor row of  a  lane, so that the system can easily 

differentiate between an axle with two wheels (normal axle) and an axle having only one wheel 

(motorbike axle). 

To protect  from heavy  traffic,  the  sensor  shall be  covered with  a minimum of   10 mm  resin 

below the surface of  the road and the resin of  the installed sensor shall have minimum life span 

of  5 years. 

Page 15: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 15/21

Page 15 of  21 

The temperature ranges of  pavements in which the sensor shall work are ‐40 C to +80 C. 

ATCC Vehicle Detector Loop Vehicle

 Detector

 Loop

 shall

 be

 square

 or

 rectangular

 in

 shape

 to

 ensure

 proper

 coverage

 of 

 the

 lane width and shall be placed systematically between the piezo sensors. 

Loop detectors shall be provided for interface to these detector loops. Loop detectors shall be 

installed in the ATCC Controller cabinet. 

Detector  loop  shall  be  of   readymade  type  with  minimum  of   4  turns  of   AWG  #18  wire, 

encapsulated  in a protective PVC  jacket. Loops shall be spliced to the shielded twisted  lead‐in 

cable in a  junction box prior to the equipment cabinet, if  required. Supplier shall avoid splicing / 

 joint in lead‐in cable as much as possible. However, if   jointing is required, the  joints shall not be 

buried, or covered with epoxy in the road or shoulder area. 

Loops and

 lead

‐in

 cables

 shall

 be

 tested

 in

 reference

 to

 earth

 ground

 with

 a Megger

 and

 resistance shall be greater than 200 mega ohms. The loop shall be checked for inductance and 

shall meet the loop amplifier manufacture’s specification. 

The temperature ranges of  pavements in which the loops shall work are ‐40 C to +80 C. 

ATCC Controller The specifications for the ATCC Controller are as follows: 

A.  Communication 

  Controller area network bus design for option to add sensor interface boards. 

  On‐board Ethernet interface 

  Two RS‐232 interface 

  Remote administration via Telnet or web based program 

  Remote file download 

B. Storage 

  Non‐volatile local storage for vehicle information to prevent data loss during power 

outages 

C. Software

 

  Shall be capable of  simultaneous processing of  6 lanes of  traffic data. 

  User‐definable classification scheme and parameters. 

D. Local user interface 

  Display with application‐specific Keypad 

Page 16: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 16/21

Page 16 of  21 

E. Enclosure 

  19” rack mount 

  Powder coated 

  IP 66 rated 

ATCC Power backup Capable of   feeding power  to ATCC Controller,  to perform  its  full  function up  to 48 hours of  

continuous power outage. 

ATCC General Requirements The ATCC Controller and software shall provide the following minimum functions: 

A.  The recording and display unit shall work accurately between ‐200 C to +600 C. 

B.  Perform data collection, data storage, file management and report generation functions 

for collected vehicle information. 

C.  Insert sequence numbers for vehicle records. 

D.  The Controller shall provide a facility for viewing current vehicle records of  a single or 

multiple lane and sensor diagnostics directly, without any ancillary equipment. 

E.  The  Controller  system  shall  be  of   modular  design  to  aid  in  system  maintenance, 

troubleshooting and in‐field servicing. 

F.  All  components  of   the  Controller,  including  inductive  loop  detectors,  shall  contain 

necessary electrical protection to prevent damage from electrical surges, spikes and the 

effects of  lightning. 

G.  The  Controller  shall  be  of   durable,  industrial  design  and  construction  and  enable 

continuous  operation,  with  automated  start‐up  in  the  event  of   power  outage  and 

restoration. 

H.  All  sensor  and  ancillary  equipment  connections  shall  be  conveniently  located  in  the 

Controller  front panel. All connections, where possible, shall be plug‐in, quick connect 

style. 

I.  All wires  from axle  sensors,  loops, data  transmission  lines etc  shall be  terminated on 

separate terminals inside the ATCC Controller, for easy removal of  controller electronics 

during  maintenance.  The  terminals  shall  be  identified  by  terminal  number.  These 

terminals shall be easily accessible. All cables shall be long enough to easily reach these 

terminals. Terminals, splices, or any other type of  connections prior to these terminals 

shall not be allowed except for splicing of  a loop to a shielded twisted loop lead‐in cable. 

Page 17: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 17/21

Page 17 of  21 

J.  All AC power connections shall be shielded to prevent electrical shock. 

K.  Free space  in the bottom of  the cabinet shall be a minimum of  12  inches to allow the 

pulling  of   cables  without  removing  any  equipment.  The  Controller  shall  be  set  on 

shelves or mounted with  support bracket underneath. The arrangement  shall provide 

easy access to the keypad and view of  the display. 

LED status indicator for correct / faulty operation of  ATCC Controller, with different colours 

Pavement Quality concrete for ATCC shall be executed by MRMPL. 

6. Mobile Communication System (MCS) Will be provided by using GSM/CDMA Mobile phones by the client. Only  interfacing with ECB 

system shall be included in scope of  work of  Agency. 

7. Control Centre 

Central Control Room (Control Centre): The Central Control Room (CCR) shall be the repository 

of   all  the  data  acquired  from  the  field  and  their  processing,  storing,  and  archiving.  All  the 

information for real time monitoring of  the Project Highway shall be generated at the CCR and 

the  relevant  information  shall be disseminated  to  the users  through Variable message  signs, 

and to the operation and management teams through mobile radio communication system for 

appropriate  intervention. Another  important  function  to be performed at  the Control centre 

shall be the operation and management of  the A TMS itself  along with its various sub systems. 

CCR shall have the following minimum equipment, hardware and software: 

1.  A Central Computer Server with integrated ATMS and ATMS software (SCADA) 

2.  A Traffic Manager's Terminal for operation of  the integrated traffic management system 

3.  Call system equipment comprising Operator PC along with sub‐systems and digital voice 

recorder. 

4.  Mobile radio terminal comprising Operator PC and engineering terminal 

5.  Computers  for Network Management  Systems  (NMS)  for  Fiber Optic  Communication 

System. 

6.  CCTV Console

 Equipment

 

7.  Computers for VMS,AVCC,MET, Traffic Control 

8.  A large size screen (Video Wall) 

9.  A line Printer 

10. A Power Supply and back up system 

Page 18: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 18/21

Page 18 of  21 

Control Center Components The Control Center shall consist of  the following system components: 

a.  Server with Windows 7 OS and Oracle database, RAID 5 with 17" TFT, Keyboard and 

mouse 

b.  Administrator workstation 

c.  120" Video Wall 

d.  Rack 42" for mounting Server and other equipments 

e.  Printer 

f.  Power Cable & Lane Cable 

g.  Computers for Network Management Systems (NMS) for Fiber Optic Communication 

System. 

h.  Computers for

 VMS,AVCC,MET,

 Traffic

 Control

 

i.  Min 6 KVA UPS with one hour backup .shall be as per actual requirements+ 30% 

 j.  Network Switch 16 Port 

k.  Cabling Work 

Notes : 1)   All   equipments &  components  shall  be  safe guarded  against   power   fluctuation as  per  

 prevailing condition of  Gujarat  & Maharashtra. 2)  Necessary  OFC  duct  will  be laid  in median only  with HDPE   pipe. 3)  Warranty   for  the equipments supplied  and  installed  will  be  for  24 months  from the date 

of  satisfactory  commissioning of  the system. 4)  The work  will   be  completely   on  turnkey   basis. Civil  work   of   control   room with  power  

supply  at  one location in the control  room shall  be  provided  by  MRMPL. Power  supply   for   functioning of   equipment   (excluding ECBs’) along  the  project   length at   predetermined  locations at  outer  edge of  carriageway   shall  be  provided  by  MRMPL. Rating of   power  requirement    for   all   such  locations  will   have  to  be  specified   by   successful   bidder  specifically. 

5)  The scope of  work  shall  also include all  such items which are not  specifically  mentioned  in the scope, but  which are necessary   for  the satisfactory  completion of  the entire scope of   work   unless  otherwise  specifically   excluded    from  the  scope.   Any   crossing  of  constructed  road   shall  be through  pipe laid  by  trenchless technology. 

Page 19: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 19/21

Page 19 of  21 

Bill of  Quantities Sr. No.  Description  Unit  Quantity 1  Providing & installation of  CCTV Systems 

including PTZ

 video

 cameras,

 its

 housing

 and

 

pan, and Tilt heads, Pole & Mounting, Channel 

Video Server, Network Video Recorder with 6 

TB storage including all the required 

peripherals, all leads & lifts, transportation, 

material, manpower, taxes (including WCT, VAT 

& Service tax) etc. complete on turnkey basis as 

per attached “User requirement specifications 

for Advanced Traffic Management System 

Equipments” & instruction of  Authorized 

representative 

of  

MRMPL. 

No.  10 

2  Providing & installation of  Variable Message 

Signs (VMS) Systems for Text & Graphics 

including “T” type Gantry for both side VMS 

board of  size 1800 (H) X 3000 (W) x 225 (D) mm 

(Display area‐full area matrix), VMS Software, 

Copper Strip for Earthing, Data cable, Power 

cable, VMS Work station, Control Center 

Cabling including all the required peripherals, 

all leads & lifts, transportation, material, 

manpower, 

taxes 

(including 

WCT, 

VAT 

Service tax) etc. complete on turnkey basis as 

per attached “User requirement specifications 

for Advanced Traffic Management System 

Equipments” & instruction of  Authorized 

representative of  MRMPL. 

No.  06 

3  Providing & erection of  Emergency Call Boxes 

including yellow colour powder coated M.S. 

ECB housing, loud speaker, micro phone, push‐

button, LED Indicator, processing electronics, 

battery pack

 with

 48

 hours

 back

 up,

 solar

 panel,

 termination assembly, control room software, 

control cabling, OFC cabling work in Median 

including all the required peripherals, all leads 

& lifts, transportation, material, manpower, 

taxes (including WCT, VAT & Service tax) etc. 

complete on turnkey basis as per attached 

“User requirement specifications for Advanced 

No.  240 

Page 20: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 20/21

Page 20 of  21 

Traffic Management System Equipments” & 

instruction of  Authorized representative of  

MRMPL. 

4  Providing & erection of  MET Systems including, 

Ambient Temperature Sensor, Wind speed and 

direction sensor, Road surface temperature 

sensor, Relative humidity sensor, Visibility 

sensor, Data logger, Solar panel & battery, 

NEMA‐4 enclosure & mast accessories, cable 

and accessories required in control room, G.I. 

pipe for mounting, Chainlink fencing (2.5 m 

height) along with anti‐intrusion barbed wire 

coils mounted on top including all the required 

peripherals, all leads & lifts, transportation, 

material, manpower, taxes (including WCT, VAT 

& Service

 tax)

 etc.

 complete

 on

 turnkey

 basis

 as

 

per attached “User requirement specifications 

for Advanced Traffic Management System 

Equipments” & instruction of  Authorized 

representative of  MRMPL. 

No.  02 

5  Providing & erection of  Automatic Traffic 

Counter‐cum‐Classifier (ATCC) including Piezo 

Sensors for axle counting, Vehicle detector 

loop, ATCC controller and its enclosure, In‐built 

Power backup, Vehicle Traffic classifier, UPP 9 

pin Serial

 Cable

‐6’,

 PU200/S

 Piezo

 installation

 

resin, UPP Power supply AC/DC, ATCC software, 

work station for ATCC, UPP LNPC Loop cable, 

Loop cable with Loop filler including all the 

required peripherals, all leads & lifts, 

transportation, material, manpower, taxes 

(including WCT, VAT & Service tax) etc. 

complete on turnkey basis as per attached 

“User requirement specifications for Advanced 

Traffic Management System Equipments” & 

instruction of 

 Authorized

 representative

 of 

 MRMPL. 

No.  02 

6  *Mobile Communication System (MCS) : Will be 

provided by using GSM/CDMA Mobile phones 

by the client & Interfacing with ECB system 

including all the required peripherals, all leads 

& lifts, transportation, material, manpower, 

No.  Nil* 

Page 21: Atms (Sdbot)

8/13/2019 Atms (Sdbot)

http://slidepdf.com/reader/full/atms-sdbot 21/21

Page 21 of  21 

taxes (including WCT, VAT & Service tax) etc. 

shall be included in scope of  work of  Agency. 

7  Control Centre : Includes Server with Windows 

7 OS and oracle database, RAID 5 with 17” TFT, 

Keyboard and mouse, Administration 

workstation, 120” Video Wall, Rack 42” for 

mounting Server and other equipments, 

Printer, Power cable & Lane Cable, Computers 

for Network Management Systems (NMS) for 

Fiber Optic Communication System, Computers 

for VMS, AVCC, MET, Traffic Control, Min 6 KVA 

ups with one hour backup, Network Switch 16 

port, Cabling work including all the required 

peripherals, all leads & lifts, transportation, 

material, manpower, taxes (including WCT, VAT 

& Service

 tax)

 etc.

 complete

 on

 turnkey

 basis

 as

 

per attached “User requirement specifications 

for Advanced Traffic Management System 

Equipments” & instruction of  Authorized 

representative of  MRMPL. 

No.  01 

* Interfacing with ECB system shall be included in scope of  work of  Agency.