city and county of denver by mwg date · pdf filed-o4-323-cs.dwg aks aks aks park hill storm,...

15
SITE N DAHLIA ST I-70 N COLORADO BLVD E 48TH AVE N HOLLY ST SMITH RD I-70 STAPLETON DRIVE N STAPLETON DRIVE S SMITH RD PHASE IV-A PHASE V BASE BID ADD ALT. 1 ADD ALT. 2 ADD ALT. 2 PHASE V B BASE BID ADD ALT. 1 N HOLLY ST 1 OF 17 MAY 2016 D-O4-323-CS.dwg AKS AKS AKS PARK HILL STORM, PHASE V ---- ---- COVER SHEET MWG 8-23-13 PCO 100% SUBMITTAL 1 MANAGER OF PUBLIC WORKS DIVISION OF SMALL BUSINESS OPPORTUNITY SUBMITTED BY: THROUGH: DATE: DATE: DIRECTOR OF ENGINEERING PROJECT DESIGN ENGINEER APPROVED: APPROVED: APPROVED: DATE: DATE: DATE: CITY ENGINEER CITY AND COUNTY OF DENVER DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION PILAR NO. ---- PCO NO. ---- PARK HILL STORM, PHASE V PCO #2010-0087 SHEET INDEX SHEET NO. SHEET TITLE 1 COVER SHEET 2 GENERAL NOTES 3 SANITARY PLAN & PROFILE 25+50 TO 34+00 4 SANITARY PLAN & PROFILE 34+00 TO 43+00 5 SANITARY PLAN & PROFILE 43+00 TO 52+50 6 SANITARY PLAN & PROFILE 52+50 TO 55+00 7 SAN-2 SAN-3 & SAN-4 PLAN & PROFILE 8 SAN-5 & SAN-6 PLAN & PROFILE 9 STORM PLAN & PROFILE 25+50.00 TO 34+00.00 10 STORM PLAN & PROFILE 34+00.00 TO 43+00.00 11 STORM PLAN & PROFILE 43+00.00 TO 52+00 12 STORM PLAN & PROFILE 52+00.00 TO 55+00.00 13 STORM LATERALS PLAN AND PROFILE 14 PAVING PLAN 15 MEDIAN PLAN 16 MEDIAN DETAIL 17 DETAILS VICINITY MAP NTS PROJECT BENCH MARK (TVP-145) N 1/4 CORNER S19, ALUMINUM CAP IN BOX IN SOUTH BOUND LANE OF DAHLIA ST. ± 70 NORTH OF NW CORNER OF 48TH AVE AND DAHLIA ST. ELEVATION=5235.49 (NGVD 29) NO. DESCRIPTION OF REVISIONS DATE BY CITY AND COUNTY OF DENVER DEPARTMENT OF PUBLIC WORKS ENGINEERING DIVISION CAPITAL PROJECT MANAGEMENT 2000 W. 3RD AVE. DENVER, CO 80223 TEL.: (303) 446-3617 FAX: (303) 446-3647 CALL UNCC TWO WORKING DAYS BEFORE YOU DIG 1-800-922-1987 UTILITY NOTIFICATION CENTER OF COLORADO D E N V E R THE MILE HIGH CITY D E N V E R THE MILE HIGH CITY PROJECT BENCH MARK CCD BM 445 BRASS CAP IN TOP OF CURB SOUTHEAST CORNER OF DAHLIA ST AND STAPLETON DRIVE SOUTH ELEVATION=5247.10 VERTICAL DATUM NGVD 29 DRAFT 95% NOT FOR CONSTRUCTION

Upload: truongdung

Post on 25-Feb-2018

335 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

SITE

N D

AH

LIA

S

T

I-70

N C

OL

OR

AD

O B

LV

D

E 48TH AVE

N H

OL

LY

S

T

S

M

IT

H

R

D

I-

7

0

S

T

A

P

L

E

T

O

N

D

R

IV

E

N

S

T

A

P

L

E

T

O

N

D

R

IV

E

S

S

M

I

T

H

R

D

PHASE IV-A

PHASE V

BASE BID

ADD ALT. 1

ADD ALT. 2

ADD ALT. 2

PHASE V B

BASE BID

ADD ALT. 1

N H

OL

LY

S

T

1 OF 17

MAY 2016

D-O4-323-CS.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

CO

VE

R S

HE

ET

MW

G8

-2

3-1

3P

CO

1

00

% S

UB

MIT

TA

L1

MANAGER OF PUBLIC WORKS

DIVISION OF SMALL BUSINESS OPPORTUNITY

SUBMITTED BY:

THROUGH:

DATE:

DATE:

DIRECTOR OF ENGINEERING

PROJECT DESIGN ENGINEER

APPROVED:

APPROVED:

APPROVED: DATE:

DATE:

DATE:

CITY ENGINEER

CITY AND COUNTY OF DENVER

DEPARTMENT OF PUBLIC WORKS

ENGINEERING DIVISION

PILAR NO. ----

PCO NO. ----

PARK HILL STORM, PHASE V

PCO #2010-0087

SHEET INDEX

SHEET NO. SHEET TITLE

1COVER SHEET

2GENERAL NOTES

3 SANITARY PLAN & PROFILE 25+50 TO 34+00

4 SANITARY PLAN & PROFILE 34+00 TO 43+00

5SANITARY PLAN & PROFILE 43+00 TO 52+50

6SANITARY PLAN & PROFILE 52+50 TO 55+00

7SAN-2 SAN-3 & SAN-4 PLAN & PROFILE

8SAN-5 & SAN-6 PLAN & PROFILE

9STORM PLAN & PROFILE 25+50.00 TO 34+00.00

10STORM PLAN & PROFILE 34+00.00 TO 43+00.00

11STORM PLAN & PROFILE 43+00.00 TO 52+00

12STORM PLAN & PROFILE 52+00.00 TO 55+00.00

13 STORM LATERALS PLAN AND PROFILE

14PAVING PLAN

15 MEDIAN PLAN

16 MEDIAN DETAIL

17DETAILS

VICINITY MAP

NTS

PROJECT BENCH MARK (TVP-145)

N 1/4 CORNER S19, ALUMINUM CAP IN BOX

IN SOUTH BOUND LANE OF DAHLIA ST.

± 70 NORTH OF NW CORNER OF

48TH AVE AND DAHLIA ST.

ELEVATION=5235.49 (NGVD 29)

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

D E N V E RTHE MILE HIGH CITY

PROJECT BENCH MARK

CCD BM 445 BRASS CAP IN TOP OF CURB

SOUTHEAST CORNER OF DAHLIA ST

AND STAPLETON DRIVE SOUTH

ELEVATION=5247.10

VERTICAL DATUM NGVD 29

DRAFT 95%NOT FOR CONSTRUCTION

AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 2: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

2 OF 17

MAY 2016

D-O4-323-CS.dwg

AKS

MWG

MWG

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

GE

NE

RA

L N

OT

ES

MW

G8

-2

3-1

3P

CO

1

00

% S

UB

MIT

TA

L1

ADDITIONAL NOTES

1. ALL RCP SHALL MEET THE ASTM C-76 SPECIFICATION.

2. ALL RCP SHALL BE CLASS Iii UNLESS NOTED OTHERWISE.

3. ALL SURFACE WORK SHALL DONE PER CCD TRASPORTATION STANDARD DETAILS.

4. CONTRACTOR IS REQUIRED TO COORDINATE BUS STOPS AND BUS ROUTES WITH CCD TES AND RTD DURING CONSTUCTION.

5. THE CONTRACTOR SHALL PROOF ROLL THE COMPLETED EMBANKMENT, SUBGRADE CONDITIONING OR ROADWAY SUBGRADE TO

DETERMINE IF ANY SOFT, YIELDING OR OTHERWISE UNACCEPTABLE AREAS EXIST. THE INTENT IS TO ACHIEVE A STABLE PLATFORM FOR

THE PROPER PLACEMENT OF EMBANKMENT OR PAVEMENTS. THE ENGINEER MAY REQUIRE A WITNESS BE PRESENT DURING THE PROOF

ROLL TO VERIFY AREAS TO BE CORRECTED, AND REQUIRE A LOAD VERIFICATION OF THE PROOF ROLLER FROM THE CONTRACTOR. ANY

AREAS WHICH SHOW DEFLECTIONS THAT ARE NON UNIFORM OR IN EXCESS OF 0.5 INCH SHALL BE REWORKED AS APPROVED, OR

REMOVED AND REPLACED WITH APPROVED MATERIAL WITHOUT ADDITIONAL PAYMENT.

A. ALL REWORKED AREAS SHALL BE RETESTED FOR MOISTURE AND COMPACTION, AND PROOF ROLLED AGAIN AFTER THE SUBGRADE

HAS BEEN SHAPED TO THE FINAL GRADE AND CROSS SECTION.

B. THE PROOF ROLLER SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE A PNEUMATIC TIRED VEHICLE WITH TIRE

PRESSURES OF AT LEAST 100 PSI CAPABLE OF APPLYING GROUND LOADS OF AT LEAST 18,000 POUNDS PER AXLE. THE PROOF

ROLLER SHALL BE OPERATED BETWEEN 2 AND 6 MILES PER HOUR, AND SHALL ACHIEVE COMPLETE COVERAGE OF THE AREA TO

BE CONSTRUCTED WITH EMBANKMENT OR PAVEMENT MATERIALS.

C. UPON APPROVAL OF THE PROOF ROLLING; THE NEXT SOIL, AGGREGATE OR PAVEMENT LAYER SHALL BE PLACED PRIOR TO

MOISTURE OR WEATHER OR OTHER FACTORS AFFECTING THE SURFACE CONDITIONS OF THE SUBGRADE. ANY LAPSE OF MORE

THAN 24 HOURS SHALL BE APPROVED BY THE ENGINEER, OR ANOTHER PROOF ROLL WILL BE REQUIRED.

6. COMPACTION OF TOP TWO FEET OF STREET PAVING SUBGRADE IN TRENCHES SHALL MEET 95% MODIFIED PROCTOR COMPACTION, WITHIN

2% OF OPTIMUM MOISTURE BY AASHTO T-180 FOR GRANULAR SUBGRADE (A-1 THROUGH A-5), OR 95% STANDARD PROCTOR COMPACTION,

WITHIN 2% OF OPTIMUM MOISTURE BY AASHTO T-99 FOR COHESIVE CLAY OR SILT (A-6 OR A-7) TYPES OF SOIL SUBGRADE. THE T-99

METHOD MAY BE ALLOWED FOR NON-SWELLING MIXED SOILS (A-4 OR A-5). RECONDITION ON THE 12" OF OTHER SUBGRADE THAT MAY BE

EXPOSED AFTER ROTOMILL OR OUTSIDE THE TRENCH, TO THE PROPER MOISTURE AND COMPACTION LIMITS, PRIOR TO PAVING.

7. PUC DOCKET NUMBER 10A-433R: CLOSING BNSF RAILROAD CROSSING AT NORTH DAHLIA STREET BETWEEN EAST 46TH AVENUE AND EAST

48TH AVENUE AT MILE POST 7.

8. CONTRACTOR SHALL REPLACE ALL EXISTING PAVEMENT STRIPING AND SHALL COORDINATE WITH TRAFFIC ENGINEERING SERVICES PRIOR

TO INSTALLING STRIPING.

9. CONTRACTOR SHALL COORDINATE WITH DENVER FIRE IF THEY MUST REMOVE/REPLACE FIRE SUPPRESSION LINES.

ABBREVIATIONS

APPROX - APPROXIMATELY

CL - CENTER LINE

CCD - CITY AND COUNTY OF DENVER

CFS - CUBIC FEET PER SECOND

C & G - CURB AND GUTTER

C G & SW - CURB, GUTTER, & SIDEWALK

CH - CURB HEAD

CIP- CORRUGATED IRON PIPE (WATER)

CPM. - CAPITAL PROJECTS MANAGEMENT

DIP - DUCTILE IRON PIPE (WATER)

DT- DECIDUOUS TREE

DW - DENVER WATER BOARD

E - EAST

EF - EACH FACE

E.G.L. - ENERGY GRADE LINE

EOA - EDGE OF ASPHALT

ES - EACH SIDE

EX- EXISTING

EW - EACH WAY

FG - FINAL GRADE

FL - FLOW LINE

FO - FIBER OPTIC LINE

G - GAS

H.G.L. - HYDRAULIC GRADE LINE

I - INLET

INV. - INVERT

LF- LINEAR FEET

MH - MANHOLE

MJ- MECHANICAL JOINT

N - NORTH

NTS - NOT TO SCALE

OHE - OVERHEAD ELECTRIC LINE

PL - PROPERTY LINE

PVC - PLY VINYL CHLORIDE

q - DESIGN FLOW

Qfull - FULL FLOW CAPACITY

RCBC - REINFORCED CONCRETE BOX CULVERT

RCP - REINFORCED CONCRETE PIPE

R.L. - RANGE LINE

S - SOUTH

STM - STORM SEWER

SS - SANITARY SEWER

SW - SIDEWALK

TELE- TELEPHONE LINE

TOC - TOP OF CONCRETE

T.O.P. - TOP OF PIPE

T.O.W. - TOP OF WALL

TYP. - TYPICAL

UE - UNDERGROUND ELECTRIC LINE

U.N.O. - UNLESS NOTED OTHERWISE

VCP - VITRIFIED CLAY PIPE

W - WEST

WAT - WATER

WMD - WASTEWATER MANAGEMENT DIVISION

7'

EXISTING FEATURES LEGEND

EXISTING STREET LIGHT

EXISTING UTILITY/POWER POLE

EXISTING GUY WIRE

EXISTING TRAFFIC POLE

EXISTING TRAFFIC CONTROL BOX

EXISTING TRAFFIC CONTROL SWITCH BOX

EXISTING ELECTRIC METER

EXISTING ELECTRIC BOX

EXISTING FIRE HYDRANT

EXISTING WATER VALVE

EXISTING WATER MH

EXISTING WATER METER

EXISTING GAS MANHOLE

EXISTING STORM INLETS

EXISTING STREET SIGN

EXISTING POST

EXISTING TRASH RECEPTACLE

EXISTING TRASH DUMPSTER

EXISTING BUS BENCH

EXISTING MAIL BOX

EXISTING NEWSPAPER BOX

EXISTING TELEPHONE MH

EXISTING TELEPHONE BOX

EXISTING TELEPHONE BOOTH

EXISTING TREE

EXISTING SHRUB

SURVEY FEATURES LEGEND

BENCHMARK

CHISELED 'X'

TRAVERSE POINT

RANGE POINT

LAND CORNER

PIN & CAP

REBAR

EASEMENT LINE

SECTION LINNE

PROPERTY LINE (NOT R.OW.)

RANGELINE

R.O.W. LINE

EXISTING WATER LINE

EXISTING GAS LINE

EXISTING STORM LINE W/MANHOLE

EXISTING SANITARY LINE W/MANHOLE

EXISTING UNDERGROUND TELEPHONE LINE

EXISTING OVERHEAD TELEPHONE LINE

EXISTING TRAFFIC CONTROL LINE

EXISTING UNDERGROUND ELECTRIC

EXISTING OVERHEAD ELECTRIC

EXISTING FENCE

EXISTING 5' INTERVAL CONTOUR

EXISTING 1' INTERVAL CONTOUR

PROPOSED FEATURES LEGEND

PROPOSED NO. 16 STORM INLET

PROPOSED NO. 14 STORM INLET

PROPOSED STORM SEWER W/MANHOLE

PROPOSED 5' INTERVAL CONTOUR

PROPOSED 1' INTERVAL CONTOUR

PROPOSED CURB & GUTTER

PROPOSED GUTTER

PROPOSED WATER

PROPOSED WATER VALVE

PROPOSED WATER REDUCER

PROPOSED WATER BENDS AND/OR TEES

PROPOSED GRASS AND/OR MULCH-

REPLACE EXISTING LANDSCAPING MATERIAL

PROPOSED CONCRETE UNLESS SPECIFIED OTHERWISE

PROPOSED CURB RAMP

PROPOSED DRAINAGE FLOW ARROW

GENERAL NOTES :

1. CONTRACTORS PERFORMING WORK ON ANY WASTEWATER FACILITY OR APPURTENANCE MUST BE PROPERLY LICENSED AND HAVE A

LICENSED PLUMBER OR DRAINLAYER ON SITE DURING THE WORK. (GENERAL CONTRACT CONDITIONS (G.C.C.) 317.1)

2. THE CURRENT EDITION OF THE WASTEWATER MANAGEMENT DIVISION STANDARD DETAILS SHALL APPLY TO ALL WORK AND WILL BE THE

EDITION CURRENT AS OF THE ADVERTISEMENT DATE. THE CONTRACTOR MUST BE IN POSSESSION OF THE STANDARD DETAILS AT THE

PRE-CONSTRUCTION CONFERENCE AND A COPY MUST REMAIN ON THE JOB SITE AT ALL TIMES DURING CONSTRUCTION.

WASTEWATERMANAGEMENT DIVISION STANDARD DETAILS CAN BE OBTAINED AT WWW.DENVERGOV.ORG(SPECIAL CONTRACT

CONDITIONS (SC-1), CONTRACT FORM - 8 (APPLICABLE LAWS)

3. THE CONTRACT SPECIFIED EDITION OF THE CITY AND COUNTY OF DENVER'S TRANSPORTATION STANDARDS AND DETAILS FOR THE

ENGINEERING DIVISION SHALL BE FOLLOWED FOR ALL ROADWAY WORK IN THE PLAN SET AND WILL BE THE EDITION CURRENT AS OF THE

ADVERTISEMENT DATE. THESE STANDARDS AND DETAILS CAN BE OBTAINED AT WWW. DENVERGOV.ORG (SC-1, CONTRACT FORM - 8

(APPLICABLE LAWS))

4. THE CONSTRUCTION ACTIVITIES STORMWATER DISCHARGE PERMITS (STATE AND LOCAL FLOODPLAIN PERMITS), STREET-CUT PERMIT,

AND STREET OCCUPANCY PERMIT (INCLUDING THE ASSOCIATED TRAFFIC CONTROL PLANS) MAY BE REQUIRED AND IT IS THE

CONTRACTOR'S RESPONSIBILITY TO OBTAIN ALL OF THESE PERMITS. APPROVED COPIES OF ALL REQUIRED PERMITS MUST BE SUBMITTED

TO THE CITY CONSTRUCTION PROJECT MANAGER PRIOR TO THE START OF CONSTRUCTION. (G.C.C. 301.2, 317.1 & 317.2& 317.5; CONTRACT

FORM - 8 (APPLICABLE LAWS))

5. A PARKS PERMIT WILL BE REQUIRED FOR ANY WORK OR OCCUPANCY OF PARK LAND, THIS INCLUDES BUT IS NOT LIMITED TO:

DESIGNATED CITY PARKS, PARKWAYS, OPEN SPACE, TRAILS AND BIKE PATHS. (G.C.C. 301.2, 317.1 & 317.2& 317.5; CONTRACT FORM - 8

(APPLICABLE LAWS)

6. ALL DESIGN DRAWINGS PROVIDED AS PART OF THIS CONTRACT ARE FORMATTED FOR PRINTING FULL SIZE, ON STANDARD 22 X 34 INCH

(ANSI D) PAPER SIZE AND TO HALF-SIZE (AND SCALE WHERE APPROPRIATE) ON STANDARD 11 X 17 PAPER SIZE. IT IS THE CONTRACTOR'S

RESPONSIBILITY TO ENSURE THAT HARD COPIES OF PLANS UTILIZED FOR BIDDING OR CONSTRUCTION ARE PRINTED ON THE PROPER

MEDIA SIZE AND THAT SCALES PROVIDED WITHIN THE DRAWINGS ARE CORRECTLY INTERPRETED.

7. "RED-LINED" DRAWINGS AND PRINTS ARE TO BE MAINTAINED BY THE CONTRACTOR AND SUBMITTED TO THE CITY CONSTRUCTION

PROJECT MANAGER AT THE COMPLETION OF THE PROJECT. ANY AND ALL FIELD CHANGES MADE DURING CONSTRUCTION MUST BE

NOTED. THE DRAWINGS WILL STATE "RED LINES" IN LARGE BLOCK LETTERS. THE RED-LINED DRAWINGS MUST BE RECEIVED AND

ACCEPTED BY THE CITY CONSTRUCTION PROJECT MANAGER PRIOR TO FINAL ACCEPTANCE AND SETTLEMENT.

8. THE CONTRACTOR SHALL NOTIFY THE CITY CONSTRUCTION PROJECT MANAGER IMMEDIATELY OF "ANY" DISCREPANCIES OR VARIATIONS

IN DRAWINGS & SPECIFICATIONS THAT EFFECT PRICING OR THAT COULD REQUIRE MODIFICATION TO THE DESIGN. (G.C.C.1103)

9. THE CITY AND COUNTY OF DENVER ASSUMES NO RESPONSIBILITY FOR UTILITY LOCATIONS. THE UTILITIES SHOWN ON THESE DRAWINGS

HAVE BEEN PLOTTED FROM THE BEST AVAILABLE INFORMATION. ALL UTILITIES MUST BE LOCATED BY THE CONTRACTOR. ALL COSTS

ASSOCIATED WITH FIELD VERIFICATION OF LOCATION AND DEPTHS OF UTILITIES AND SHALL BE BORNE BY THE CONTRACTOR AND SHALL

BE COMPLETED PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION.(G.C.C. 701, 804)

10. ALL RANGE POINTS OR OTHER SURVEY MONUMENTS WHICH MAY BE DAMAGED OR DESTROYED DURING CONSTRUCTION SHALL BE TIED

OUT AND RESET BY THE PER CITY SURVEYING STANDARDS. (G.C.C. 318, 319)

11. ALL ELEVATIONS SHOWN ARE NAVD88 DATUM, UNLESS OTHERWISE NOTED.

12. INLETS AND MANHOLES ARE NOT SHOWN TO SCALE ON THE PLAN AND PROFILE SHEETS.

13. INVERT ELEVATIONS AND CALCULATED PIPE SLOPES ON STORM AND SANITARY PROFILES ARE TO THE CENTER OF MANHOLE OR

STRUCTURE. PIPE LENGTHS ARE TWO DIMENSIONAL LENGTHS AND ARE CENTER TO CENTER BETWEEN MANHOLES AND TO THE INSIDE

EDGE OF INLETS.

14. NORTHING AND EASTING CALLOUTS ON TYPE 16 AND TYPE 14 INLETS ARE TO THE CENTER OF THE STRUCTURE AT THE FLOWLINE.

NORTHING AND EASTING CALLOUTS ON MANHOLES ARE TO THE CENTER OF THE MANHOLE.

15. LOCATION OF INLETS AND/OR INLET CONNECTORS MAY BE ADJUSTED IN THE FIELD AT THE DIRECTION OF THE CITY CONSTRUCTION

PROJECT MANAGER IN CONJUNCTION WITH DESIGN INTENTION. ALL INLET CONNECTIONS SHOWN IN PLAN AND PROFILE ARE

APPROXIMATE LOCATIONS AND DEPTHS.

16. DEPTHS OR BOTTOM OF STRUCTURE ELEVATIONS WILL NOT BE PROVIDED FOR INLETS WITHIN THE PROJECT SCOPE, AS THESE ARE

REQUIRED TO BE DETERMINED BASED ON FIELD CONDITIONS IN ACCORDANCE WITH APPLICABLE STANDARD DETAIL DRAWINGS. IT SHALL

BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ESTABLISH INLET DEPTHS AND COMPLETE CONSTRUCTION IN

CONFORMANCE WITH APPLICABLE STANDARD DETAIL DRAWINGS BASED ON CLEARANCES OF ADJACENT UTILITIES WHILE MAINTAINING

MINIMUM REQUIRED GRADES ON LATERAL CONNECTIONS.

17. ALL SEWER MANHOLES MUST BE MAINTAINED AND ACCESSIBLE DURING CONSTRUCTION.

18. ALL SANITARY MANHOLES ARE 4' DIAMETER WITH "A" BASE AND CONCENTRIC CONE UNLESS NOTED OTHERWISE.

19. ALL MANHOLES BUILT WITHIN THIS PROJECT SHALL INCLUDE EITHER A 4" OR 8" CAST IRON RISER WITH 3" STEEL ADJUSTING RINGS.

DENVER WATER

20. IT SHALL BE THE CONTRACTOR'S RESPONSIBLITY TO TAKE WHATEVER STEPS NECESSARY TO PROTECT ALL WATER FACILITIES. IF ANY

WATER FACILITIES CANNOT BE ADEQUATELY PROTECTED, THEN SAID WATER FACILITIES SHALL BE RELOCATED OR REMOVED IN

ACCORDANCE WITH THE DENVER WATER DEPARTMENT REQUIREMENTS, BY A DENVER WATER PREQUALIFIED CONTRACTOR.

21. CONSTRUCTION ACTIVITIES BY ANY PARTY THAT DISTURB, RELOCATE, SEVER, OR IN ANY OTHER WAY IMPACT A SERVICE LINE SHALL BE

REQUIRED TO MEET CURRENT DENVER WATER REQUIREMENTS FOR SERVICE LINES AS SPECIFIED IN CHAPTER 3 OF THE LATEST DENVER

WATER STANDARDS. IN THE EVENT LEAD WATER LINES ARE ENCOUNTERED, DO NOT DISTURB, IMMEDIATELY STOP WORK, AND NOTIFY

THE CITY CONSTRUCTION PROJECT MANAGER.

TREE PROTECTION

22. IF EXISTING TREES ARE TO BE REMOVED THEY MUST FIRST BE EVALUATED BY THE CITY AND COUNTY OF DENVER FORESTRY (PARKS)

DEPARTMENT AND A PERMIT MUST BE OBTAINED. EXISTING TREES TO REMAIN MUST HAVE FORESTRY APPROVED TREE PROTECTION SET

UP AROUND THEM DURING THE CONSTRUCTION AS SHOWN IN THE "INDIVIDUAL TREE PROTECTION DETAIL" IN THE DENVER PARKS

DEPARTMENT STANDARD PLANS.THE CONTRACTOR MUST FOLLOW ALL OF THE CITY AND COUNTY OF DENVER TREE RETENTION AND

PROTECTION GUIDELINES. REFER TO DENVER PARKS DEPARTMENT SPECIFICATION 01 56 39.

METRO WASTEWATER RECLAMATION DISTRICT

23. METRO WASTEWATER RECLAMATION DISTRICT MUST BE NOTIFIED AT LEAST 48 HOURS PRIOR TO CONSTRUCTION ON METRO FACILITIES

IN ORDER FOR A DISTRICT INSPECTOR TO BE PRESENT DURING CONSTRUCTION. CONTRACTOR MUST CONTACT METRO WASTEWATER

RECLAMATION DISTRICT TO SCHEDULE THE INSPECTION 303-286-6000.

ASPHALT

TEST HOLE LEGEND

GRAVEL

SAND

RUBBISH & TRASH

SILT

SILTY SAND

WATER SURFACE

ELEVATION

SILTY CLAY

SANDY CLAY

CLAY

BLUE SHALE/BED ROCK

= WATER ELEVATION

P.I. = PLASTICITY INDEX

L.L. = LIQUID LIMIT

TYPICAL

CALLOUTS

0-8' SILTY SAND

SLIGHTLY MOIST

LOOSE

L.L. = 24

P.I. = 7

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

AutoCAD SHX Text
RBR
AutoCAD SHX Text
P&C
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
WV
AutoCAD SHX Text
W
AutoCAD SHX Text
W
AutoCAD SHX Text
G
AutoCAD SHX Text
MB
AutoCAD SHX Text
NB
AutoCAD SHX Text
T
AutoCAD SHX Text
T
AutoCAD SHX Text
5210
AutoCAD SHX Text
5209
AutoCAD SHX Text
5210
AutoCAD SHX Text
5209
AutoCAD SHX Text
WV
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 3: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
121'
AutoCAD SHX Text
T
AutoCAD SHX Text
230'
AutoCAD SHX Text
T
AutoCAD SHX Text
125'
AutoCAD SHX Text
T
AutoCAD SHX Text
170'
AutoCAD SHX Text
T
AutoCAD SHX Text
227'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
TC
AutoCAD SHX Text
TH#4
AutoCAD SHX Text
TH#5
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
E
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
44'
AutoCAD SHX Text
18'
AutoCAD SHX Text
18'
AutoCAD SHX Text
44'
AutoCAD SHX Text
18'
AutoCAD SHX Text
18'
AutoCAD SHX Text
TH#5
AutoCAD SHX Text
11'-15' CLAY w/ COARSE SAND, SOFT-MOIST LL=31 PI=15
AutoCAD SHX Text
0'-2' SILT SIL-MOIST LOOSE L.L.=24 P.I.=10
AutoCAD SHX Text
15'-18' SAND w/ GRAVEL\SLI-MOIST VERY DENSE
AutoCAD SHX Text
2'-6' CLAY,SANDY\ VERY STIFF MOIST L.L.=35 P.I.=16
AutoCAD SHX Text
6'-11' CLAY,SILTY\ STIFF MOIST L.L.=30 P.I.=16
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 4: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
208'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
T
AutoCAD SHX Text
23'
AutoCAD SHX Text
T
AutoCAD SHX Text
TH#6
AutoCAD SHX Text
TH#7
AutoCAD SHX Text
TH#8
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
T
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
44'
AutoCAD SHX Text
13'
AutoCAD SHX Text
13'
AutoCAD SHX Text
15'-17' COARSE SAND & CLAYEY MOIST DENSE L.L.=29 P.I.=14
AutoCAD SHX Text
TH#6
AutoCAD SHX Text
0'-4' SILT SLI-MOIST DENSE L.L.=24 P.I.=10
AutoCAD SHX Text
14'-20' SAND w/ GRAVEL COARSE SLI-MOIST DENSE
AutoCAD SHX Text
TH#7
AutoCAD SHX Text
0'-11' SILT MOIST LOOSE P.I.=20 L.L=7
AutoCAD SHX Text
TH#8
AutoCAD SHX Text
0'-4' CLAY,SANDY SLI-MOIST SOFT L.L.=25 P.I.=11
AutoCAD SHX Text
17'-21' SAND COARSE SLI-MOIST DENSE
AutoCAD SHX Text
4'-6' CLAY & SILTY SLI-MOIST VERY STIFF L.L.=32 P.I.=16
AutoCAD SHX Text
6'-15' CLAY MOIST SOFT L.L.=34 P.I.=16
AutoCAD SHX Text
4'-14' CLAY SANDY MOIST SOFT L.L.=34 P.I.=18
AutoCAD SHX Text
16'-23' SAND & GRAVEL COARSE SLI-MOIST VERY DENSE
AutoCAD SHX Text
20'-21' SAND w GRAVEL\CLAYEY MOIST DENSE L.L.=30 P.I.=15
AutoCAD SHX Text
14'-16' SAND W/ GRAVEL CLAYEY MOIST VERY DENSE L.L.=25 P.I.=11
AutoCAD SHX Text
11'-14' SILT MOIST MEDIUM DENSE L.L.=25 P.I.= 2
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
NOTES 1. THE CITY OF DENVER ASSUMES NO RESPONSIBILITY FOR EXISTING UTILITY LOCATIONS. THE UTILITIES SHOWN ON THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS, HOWEVER, THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION. 2. SANITARY SEWER PIPE LENGTHS ARE FROM CENTER OF MANHOLE TO CENTER OF MANHOLE. 3. SANITARY SEWER MAIN SHALL BE PVC PIPE PER CITY AND COUNTY OF DENVER TECHNICAL SPECIFICATIONS. 4. CONTRACTOR TO LOCATE AND VERIFY ALL EXISTING LIVE TAPS AND CONNECT TO PROPOSED SANITARY SEWER.
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 5: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced
AutoCAD SHX Text
P&C
AutoCAD SHX Text
P&C
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
222'
AutoCAD SHX Text
T
AutoCAD SHX Text
310'
AutoCAD SHX Text
TC
AutoCAD SHX Text
P&C
AutoCAD SHX Text
P&C
AutoCAD SHX Text
TH #10
AutoCAD SHX Text
TH #9
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
E
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
E
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
44'
AutoCAD SHX Text
13'
AutoCAD SHX Text
13'
AutoCAD SHX Text
EXISTING 4" VCP (PRIVATE) CONNECT TO PROPOSED MANHOLE WITH OUTSIDE DROP PER CCD STANDARDS
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
NOTES 1. THE CITY OF DENVER ASSUMES NO RESPONSIBILITY FOR EXISTING UTILITY LOCATIONS. THE UTILITIES SHOWN ON THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS, HOWEVER, THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION. 2. SANITARY SEWER PIPE LENGTHS ARE FROM CENTER OF MANHOLE TO CENTER OF MANHOLE. 3. SANITARY SEWER MAIN SHALL BE PVC PIPE PER CITY AND COUNTY OF DENVER TECHNICAL SPECIFICATIONS. 4. CONTRACTOR TO LOCATE AND VERIFY ALL EXISTING LIVE TAPS AND CONNECT TO PROPOSED SANITARY SEWER.
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 6: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

5220

5225

5230

5235

5240

5245

5250

5255

5260

5220

5225

5230

5235

5240

5245

5250

5255

5260

-0+50 0+00 1+00

5220

5225

5230

5235

5240

5245

5250

5255

5260

5220

5225

5230

5235

5240

5245

5250

5255

5260

-0+50 0+00 1+00

SA

N M

H-A

11

ST

A: 35+

45.44

RIM

=

5245.95

24" IN

V. IN

=

5222.02 (S

)

24" IN

V. O

UT

=

5222.02 (N

)

12" IN

V. IN

=

5222.97 (E

)

CU

T=

23.93

SA

N M

H-A

11.1

ST

A: 35+

48.98

RIM

=

5245.71

12" IN

V. O

UT

=

5223.36 (W

)

12" IN

V. IN

=

5228.55 (E

)

12" IN

V. IN

=

5225.62 (E

)

CU

T=

22.36

19.42 LF

@ 2.00%

12" PVC

EX 12" WAT FIELD VERIFY

(ASSUMED T.O.P.)

STA: 35+47.16

T.O.P.=5241.39

500.09 LF

@ 0.30%

84" RCP

SA

N M

H-A

12

ST

A: 37+

58.82

RIM

=

5246.97

24" IN

V. IN

=

5222.70 (S

)

24" IN

V. O

UT

=

5222.70 (N

)

12" IN

V. IN

=

5222.89 (E

)

CU

T=

24.27

500.09 LF

@ 0.30%

84" RCP

SA

N M

H-A

12.1

ST

A: 37+

61.73

RIM

=

5246.85

12" IN

V. O

UT

=

5223.16 (W

)

CU

T=

23.69

18.44 LF

@ 1.48%

12" PVC

EXISTING GROUND @

CENTERLINE OF PIPE

EXISTING GROUND @

CENTERLINE OF PIPE

EX 12" WAT FIELD VERIFY

(ASSUMED T.O.P.)

STA: 37+70.07

T.O.P.=5242.50

295.83 LF

@ 0.25%

EX 12 SAN"

STMSTM

STM

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G G

G A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

N

S

A

N

S

A

N

SAN

SAN

S

A

N

S

A

N

S

A

N

S

A

N

S

A

N

SA

N

S

A

N

FIB

ER

OP

TIC

CA

BIN

ET

EX

O

HE

EX

O

HE

EX OHE

EX OHE

EX OHE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

W A

BA

NW

A

BA

NW

A

BA

N

FO ABAN

T

T

T

M

M

FO

FO

FO

W

W

W

W

W

W

FO

FO

FO

W

G

FO

FO

FO

FO

FO

FO

FO

FO

FO

W

W

W

W

W

W

W

W

W

FO

FO

FO

FO

FO

G

FO

FO

FO

FO

FO

FO

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

GG

G

G

G

G

G

G

W ABAN

W ABAN

KB

-4

SAN MH-A12 5'Ø

STA 0+00.23, -10.12' L

SAN MH-A11 5'Ø

STA 0+10.48, 0.00'

N=3791.4670

E=7492.0058

SAN MH-A10 4'Ø

STA 34+27.11, 0.00'

N=3909.7883

E=7493.6652

213.38 LF

24" PVC

118.33 LF

24" PVC

EX SAN MH 5 4'Ø

TO BE REMOVED

EX SAN MH 6 4'Ø

TO BE REMOVED

EX SAN MH 74 4'Ø

EX SAN MH 76 5'Ø

EX 18" PVC

TO BE REMOVED

EX 18" PVC

EX 12" PVC

BEGIN PIPE JACKING

STA=34+72.57

OFF=0.000

N=3864.3286

E=7493.0276

STAPLETON DR. N.

INTERSTATE-70(ELEVATED)

PROPOSED 341 LF OF 21" PVC

BY BORING/JACKING

WITH STEEL PIPE CASING

PER CCD SPECIFICATIONS

E=7482.5296

EX TELEPHONE

VAULT

SAN MH-A11.1 4'Ø

(OUTSIDE DROP)

STA 0+29.90, 0.00'

N=3787.6582

E=7511.0493

19.42 LF

12" PVC

EX 12" CI WAT

EX 6" GAS MW

EX 6" GAS MW

34

+0

0

35+

00

36+

00

37+

00

0

+

0

0

0

+

5

0

SAN-3

EX 12" CI WAT (1955)

EX 6" GAS MW

EX FIBER OPTIC

(AIRTOUCH)

EX COMCAST TV

G A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

N

G A

BA

NG

A

BA

N

G A

BA

N

S

A

N

SA

N

S

A

N

S

A

N

S

A

N

S

A

N

SA

NS

AN

SA

NS

AN

F

O

A

B

A

N

F

O

A

B

A

N

EX

C

AB

LE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

W

W

W

XX

XX

XX

XX

XX

X

X

X

W A

BA

NW

A

BA

NW

A

BA

N

W A

BA

N

FO

FO

FO

FO

FO

W

W

W

W

W

W

FO

FO

FO

F

O

F

O

FO

FO

FO

FO

FO

FO

FO

FO

FO

W

W

W

S

A

N

S

A

N

FO

FO

FO

FO

FO

FO

G

G

G

G

G

G

G

G

G

G

KB

-5

SAN MH-A13 4'Ø

SAN MH-A12 5'Ø

STA 0+00.23, -10.12' L

N=3578.1242

E=7488.0055

206.37 LF

24" PVC

213.38 LF

24" PVC

END PIPE JACKING

STA=38+13.57

OFF=0.000

N=3523.3621

E=7488.2460

EXISTING TAP

(TYP)

N D

AH

LIA

ST

STAPLETON DR. S.

INTERSTATE-70(ELEVATED)

EX 15" STM

EX 12" CI WAT

EX SAN FROM BAKERY

CONTRACTOR TO FIELD VERIFY

PIPE SIZE AND USE THAT PIPE SIZE

EX ABANDONEDSANITARY

STA 0+29.90, 0.00'

N=3787.6582

E=7511.0493

SAN MH-A12.1 4'Ø

(OUTSIDE DROP)

STA 0+18.62, -8.70' L

N=3574.9519

E=7506.1700

18.44 LF

12" PVC

36+

00

37+

00

38+

00

39+

00

0+

00

0+

28.6

7

SAN-4

SAN-5

EX FIBER OPTIC

(AIRTOUCH)

EX COMCAST TV

N

SAN-3 PLAN & PROFILE

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

SAN-4 PLAN & PROFILE

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

7 OF 17

MAY 2016

D-04-323-SAN-02.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

SA

N-2 S

AN

-3 &

S

AN

-4 P

LA

N &

P

RO

FILE

AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
5227.12
AutoCAD SHX Text
5228.09
AutoCAD SHX Text
5227.30
AutoCAD SHX Text
5229.04
AutoCAD SHX Text
5228.94
AutoCAD SHX Text
5232.00
AutoCAD SHX Text
5232.10
AutoCAD SHX Text
TH#6
AutoCAD SHX Text
E
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
44'
AutoCAD SHX Text
18'
AutoCAD SHX Text
18'
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
208'
AutoCAD SHX Text
5229.04
AutoCAD SHX Text
5228.94
AutoCAD SHX Text
5232.00
AutoCAD SHX Text
5232.10
AutoCAD SHX Text
5232.00
AutoCAD SHX Text
TH#7
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
NOTES 1. THE CITY OF DENVER ASSUMES NO RESPONSIBILITY FOR EXISTING UTILITY LOCATIONS. THE UTILITIES SHOWN ON THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS, HOWEVER, THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION. 2. SANITARY SEWER PIPE LENGTHS ARE FROM CENTER OF MANHOLE TO CENTER OF MANHOLE. 3. SANITARY SEWER MAIN SHALL BE PVC PIPE PER CITY AND COUNTY OF DENVER TECHNICAL SPECIFICATIONS. 4. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING LIVE TAPS AND CONNECT TO PROPOSED SANITARY SEWER.
AutoCAD SHX Text
SAN-3
AutoCAD SHX Text
SAN-4
AutoCAD SHX Text
SAN-2
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 7: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

5220

5225

5230

5235

5240

5245

5250

5255

5260

5220

5225

5230

5235

5240

5245

5250

5255

5260

-0+50 0+00 1+00

SA

N M

H-A

13

ST

A: 39+

65.18

RIM

=

5247.55

21" IN

V. IN

=

5223.53 (S

)

24" IN

V. O

UT

=

5223.28 (N

)

18" IN

V. IN

=

5223.73 (E

)

CU

T=

24.26

SA

N M

H-A

13.1

ST

A: 39+

65.99

RIM

=

5247.38

18" IN

V. O

UT

=

5224.06 (W

)

18" IN

V. IN

=

5229.30 (E

)

18" IN

V. IN

=

5233.50 (E

)

CU

T=

23.32

422.84 LF

@ 0.30%

84" RCP

EX 12" WAT FIELD VERIFY

(ASSUMED T.O.P.)

STA: 39+65.92

T.O.P.=5242.90

16.71 LF

@ 1.97%

18" PVC

EXISTING GROUND @

CENTERLINE OF PIPE

EX 8" SAN

OUTSIDE DROP

CONNECTION

FO (QWEST) NO LOCATE

FIELD VERIFY

STA: 0+20.49

T.O.P.=5242.29

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

NG

A

BA

N

G A

BA

N

SA

NS

AN

SA

N

SA

N

SA

N

SA

N

SA

N

EX

C

AB

LE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

XX

X

W A

BA

NW

A

BA

N

W A

BA

N

W A

BA

N

W A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

N

T

FO

FO

FO

FO

F

O

G

FO

FO

FO

FO

FO

W

W

W

W

W

W

W

W

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

G

G

G

G

G

G

G

G

SAN MH-A13 4'Ø

STA 39+65.18, 0.00'

N=3371.7644

E=7486.1200

331.77 LF

21" P

VC

206.37 LF

24" PVC

EX SAN MH 4 4'Ø

TO BE REMOVED

EX 18" PVC

TO BE REMOVED

EX 18" PVC

TO BE REMOVED

EX POWER

POLE (TYP)

OFF=0.000

N=3523.3621

E=7488.2460

EXISTING TAP

(TYP)

EX 12" CI WAT (1955)

EX 6" GAS MW

EX FIBER OPTIC

(AIRTOUCH)

EX COMCAST TV

N D

AH

LIA

ST

EX SAN FROM BAKERY

CONTRACTOR TO FIELD VERIFY

PIPE SIZE AND USE THAT PIPE SIZE

TO CONNECT TO THE SANITARY

MAIN. CONTRACTOR TO ADJUST

INVERTS AS NECESSARY.

EX TELEPHONE

EX TELEPHONE

SAN MH-A13.1 4'Ø

(OUTSIDE DROP)

STA 39+65.99, -16.69' L

N=3370.8976

E=7502.8059

16.71 LF

18" PVC

39+

00

40

+0

0

41

+0

0

0+00

0+

46.7

5

SAN-5

N D

AH

LIA

ST

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

N

SA

N

SA

N

SA

N

SA

N

SA

N

SAN

SAN

SA

N

G ABAN

W

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX OHE

XX

XX

XX

XX

XX

X

XX

XX

XX

XX

XX

XX

XX

W A

BA

NW

A

BA

N

W A

BA

N

W A

BA

N

W A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

N

W A

BA

N

W ABAN

G

FO

FO

FO

FO

FO

FO

FO

W

W

W

W

W

W

FO

FO

FO

FO

FO

FO

FO

W

W

W

G

G

GG

G

G

GG

SAN MH-A14 4'Ø

STA 42+96.96, 0.00'

N=3039.9934

E=7484.8789

331.77 LF

21" P

VC

EX SAN MH 3 4'Ø

TO BE REMOVED

EX 18" PVC

TO BE REMOVED

EX FIBER OPTIC

(AIRTOUCH)

EX COMCAST TV

EX SAN FROM BAKERY

CONTRACTOR TO FIELD VERIFY

PIPE SIZE AND USE THAT PIPE SIZE

TO CONNECT TO THE SANITARY

MAIN. CONTRACTOR TO ADJUST

INVERTS AS NECESSARY.

PROTECT

EX FIBER OPTIC

EX TELEPHONE

EX TELEPHONE

SAN MH-A14.1 4'Ø

(OUTSIDE DROP)

STA 42+97.73, -29.35' L

N=3039.2220

E=7514.2296

29.36 LF

18" PVC

41+

00

42+

00

43+

00

0+00

0+50

SAN-6

N D

AH

LIA

ST

EX 12" CI WAT (1955)

EX 6" GAS MW

5225

5230

5235

5240

5245

5250

5255

5260

5265

5225

5230

5235

5240

5245

5250

5255

5260

5265

-0+50 0+00 1+00

SA

N M

H-A

14

ST

A: 42+

96.96

RIM

=

5249.80

21" IN

V. IN

=

5224.72 (S

)

21" IN

V. O

UT

=

5224.53 (N

)

18" IN

V. IN

=

5224.75 (E

)

CU

T=

25.28

SA

N M

H-A

14.1

ST

A: 42+

97.73

RIM

=

5249.49

18" IN

V. O

UT

=

5225.04 (W

)

12" IN

V. IN

=

5231.23 (E

)

12" IN

V. IN

=

5235.00 (E

)

CU

T=

24.45

EX 12" WAT FIELD VERIFY

(ASSUMED T.O.P.)

STA: 42+97.62

T.O.P.=5245.00

422.84 LF

@ 0.30%

84" RCP

EXISTING GROUND @

CENTERLINE OF PIPE

EX 8" SAN

OUTSIDE DROP

CONNECTION

FO (QWEST) NO LOCATE

FIELD VERIFY

STA: 0+21.34

T.O.P.=5244.44

N

SAN-5 PLAN & PROFILE

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

SAN-6 PLAN & PROFILE

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

8 OF 17

MAY 2016

D-04-323-SAN-02.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

SA

N-5 &

S

AN

-6 P

LA

N &

P

RO

FILE

AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
208'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
T
AutoCAD SHX Text
23'
AutoCAD SHX Text
T
AutoCAD SHX Text
5233.11
AutoCAD SHX Text
5233.11
AutoCAD SHX Text
Top=5236.42
AutoCAD SHX Text
Bottom=5234.12
AutoCAD SHX Text
TH#8
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
T
AutoCAD SHX Text
M
AutoCAD SHX Text
44'
AutoCAD SHX Text
13'
AutoCAD SHX Text
13'
AutoCAD SHX Text
5234.49
AutoCAD SHX Text
5234.51
AutoCAD SHX Text
Top=5241.11
AutoCAD SHX Text
Bottom=5235.58
AutoCAD SHX Text
TH#8
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
44'
AutoCAD SHX Text
13'
AutoCAD SHX Text
13'
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
NOTES 1. THE CITY OF DENVER ASSUMES NO RESPONSIBILITY FOR EXISTING UTILITY LOCATIONS. THE UTILITIES SHOWN ON THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST AVAILABLE INFORMATION. IT IS, HOWEVER, THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE LOCATION OF ALL UTILITIES PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION. 2. SANITARY SEWER PIPE LENGTHS ARE FROM CENTER OF MANHOLE TO CENTER OF MANHOLE. 3. SANITARY SEWER MAIN SHALL BE PVC PIPE PER CITY AND COUNTY OF DENVER TECHNICAL SPECIFICATIONS. 4. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING LIVE TAPS AND CONNECT TO PROPOSED SANITARY SEWER.
AutoCAD SHX Text
SAN-5
AutoCAD SHX Text
SAN-6
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 8: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

T

T

T

S

T

M

G

G

G

G

G

G

G

G

T

G

T

SAN

SAN

SAN

SAN

SAN

SAN

SAN

SAN

T

G A

BA

N

GG

G ABAN

G

G

A

B

A

N

G

A

B

A

N

G A

BA

N

G A

BA

N

G ABAN

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE EX OHE

EX OHE

EX

O

HE

EX

O

HE

EX

O

HE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

EX

O

HE

EX

O

HE

EX

O

HE

W

W

W A

BA

N

W ABANW ABAN

W ABANW ABAN

W ABANW ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

W ABAN

M

M

M

M

T

T

T

M

F

O

FO

G

G

FO

G

WW

W

FOFO

FO

FO

FO

FO

FO

FO FO

FO

W

W

FO

G

W

W

G

FO

FO

FO

FO

FOFO

FO

FO

FO

FOFO

FO FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FOFO

FO

FO

FO FO

FO

F

O

FO FO

FO

FO

FO

FO

FO

FO

FO

FO FO

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

S

A

N

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABANG ABAN

G ABAN

G

G

G

G

G

G

G

GG

G

G

GG

G

G

G

G

G

GG

G

G

G

G

G

W

W A

BA

N

W A

BA

N

W A

BA

N

W A

BA

N

KB-2

KB-3

KB-1

25+00

26+00

27+00

28+00

29+00

30+00

31+00

32+00

33+00

34+00

80'

R.O

.W

.

80'

R.O

.W

.

EX POWERPOLE (TYP)

EX FIBER OPTIC(AT&T)

EX CENTURYLINKFIBER OPTIC

EX TELEPHONEVAULT

EX 6" GAS MW TO BE RELOCATED

BY XCEL - CONTRACTORTO COORDINATE

CONTACT WAYNE GALLEGOS (303) 571-6632

(PRIVATE OWNERSHIP)RAIL ROAD CROSSINGCL STA: 32+28.55

BNSF

RAIL ROAD CROSSING

CL STA: 31+72.94

(PRIVATE OWNERSHIP)RAILROAD CROSSING

REMOVE AND REPLACE

RR TRACKS AS NECESSARY

CL STA: 28+51.11

(PRIVATE OWNERSHIP)RAIL ROAD CROSSINGREMOVE AND DO NOT

REPLACE RR TRACKS

PUC DOCKET NO. 10A-433R

CL STA: 28+81.09

STM MH-B8 (MH TEE)

STA 29+54.36, 0.00'

N=4382.5512

E=7501.1478

166.4 LF

84" RCP

476.3 LF

84" RCP

EX TAP(TYP)

EX 12" CI WATABANDONED

318.5 LF

84" RCP

STM MH-B9 (MH TEE)

STA 32+72.83, 0.00'

N=4064.0791

E=7501.8660

PROPOSED 120 LF OF

84" CLASS V RCP

EXISTING 12" CI WATER UNDER RR TRACKS

(APPROXIMATELY 120 LF) IS TO REMAIN IN PLACE.

THE NEW 12" WATER LINE, CONSTRUCTED

WITH PARKHILL PH IV-A,WILL CONNECT

TO THE EXISTING 12" CI WATER UNDER THE TRACKS.

EX FIBER OPTICSVAULT (TYP)

N00° 07' 28.98"W

2648.64

S89° 35' 31.02"W

2481.52

S89° 35' 14.81"W

1599.96

EX FOAT&T

EX QWESTTELEPHONE

PROTECT

EX 6" GAS MWTO BE RELOCATED BY XCEL -

CONTRACTOR TO COORDINATE

CONTACT WAYNE GALLEGOS

(303) 571-6632

48.00 LF

6" PVC WAT

STORM-3

(SEE SHEET 13)

STORM-4

(SEE SHEET 13)

CONTRACTOR TO PROTECT

EXISTING 5' WALK AND CURB

AND GUTTER . (TYPICAL)

EX CROSS PAN

TO BE REMOVED AND

REPAVED W/ AC WITH

CROWN CROSS SECTION

EXISTING

LIGHT

(TYPICAL)

EXISTINGOVERHEADELECTRIC(TYPICAL)

RELOCATE RR CROSSBUCK SIGN TO

WITHIN 12 TO 15' SOUTH OF RR

CROSSING AT STA 28+47 INSTALL A

"TRACK OUT OF SERVICE SIGN"

84 PRECAST PLUG

STA 24+78.03, 0.00'

N=4858.8788

E=7500.0735

CONTRACTOR TO PROTECT

EXISTING WATER, METER(S), AND ALL

APPURTENANCES (TYPICAL)

EX. 12" C-900 WATER

EX 12" WATER IN DAHLIA WAS RELOCATED AND

ABANDONED IN PARKHILL STORM PH IV-A.

CONTRACTOR TO REMOVE ABANDONED 12"

WATER AS NECESSARY TO INSTALL 84" STORM.

COST OF REMOVAL TO BE INCLUDED IN COST OF

84" STORM PIPE

PROTECT EX

WATER SERVICE

CONTRACTOR TO PROTECT

EXISTING 5' PAN. (TYPICAL)

CONTRACTOR TO PROTECT

EXISTING WATER, METER(S),

AND ALL APPURTENANCES

(TYPICAL)

EX. COMCAST CABLEPROTECT

PROTECT EX OVERHEAD ELECTRIC.

CONTRACTOR TO COORDINATE

RELOCATION WITH XCEL IF NECESSARY

PROTECT EX OVERHEAD ELECTRIC.

CONTRACTOR TO COORDINATE WITH

XCEL IF NECESSARY IF TEMPORARY

POWER DISCONNECTION IS NECESSARY

MA

TC

HL

IN

E 34+

00

PH

AS

E IV

-A

PH

AS

E V

BA

SE

B

ID

EX 21" SAN

EX 21" SAN

N DAHLIA STREET48T

H A

VE

NU

E

BN

SF RR

S89° 35' 31.02"W

2481.52

S89° 35' 31.02"W

2481.52

122.90 LF

12" PVC WAT

KB-1

KB-2

KB-3

WC=11.1DD=118.3-200=45LL=20PI=5A-4 (0)

WC=3.6DD=112.2+4=15-200=5NVNPA-1-b (0)

WC=3.6DD=111.0+4=0-200=10NVNPA-3 (1)

WC=7.0DD=122.8+4=0-200=31LL=19PI=1A-2-4 (0)

WC=3.4DD=110.0+4=6-200=5NVNPA-1-b (0)

WC=3.2DD=119.5+4=11-200=7NVNPA-1-b (1)

WC=13.3DD=111.3+4=0-200=54LL=31PI=18A-6 (6)

166.4 LF @ 0.30%

84" RCP

476.3 LF @ 0.30%

84" RCP

ST

M M

H-B

8 (M

H T

EE

)

ST

A: 29+

54.36

RIM

=

5238.68

84" IN

V. IN

=

5224.80 (S

)

84" IN

V. O

UT

=

5224.80 (N

)

18" IN

V. IN

=

5230.83 (W

)

18" IN

V. IN

=

5230.83 (E

)

EX 10" WATSTA: 32+86.37T.O.P.=5236.05

EX T

V F

O 2

-2"

STA

: 28+

34.5

2T.

O.P

.=5235.8

1

EX 2

" WAT

SER

VIC

ESTA

: 30+

15.9

4T.

O.P

.=5235.0

6

EX 12" WATSTA: 29+45.06T.O.P.=5234.21

EX 1

0" W

AT

STA

: 26+

56.3

4T.

O.P

.=5232.7

5

EX 1

2" W

AT

STA

: 25+

79.9

8T.

O.P

.=5232.6

2

RAIL

RO

AD

CRO

SSIN

GCL

STA

: 28+

51.1

1

RAIL

RO

AD

CRO

SSIN

GCL

STA

: 28+

81.0

9

RAIL

RO

AD

CRO

SSIN

GCL

STA

: 31+

72.9

4

RAIL

RO

AD

CRO

SSIN

GCL

STA

: 32+

28.5

5

318.5 LF @ 0.30%

84" RCP

ST

M M

H-B

9 (M

H T

EE

)

ST

A: 32+

72.83

RIM

=

5241.59

84" IN

V. IN

=

5225.76 (S

)

84" IN

V. O

UT

=

5225.76 (N

)

18" IN

V. IN

=

5231.86 (W

)

18" IN

V. IN

=

5231.86 (E

)

EXISTING GROUND

AT CL OF PIPE

EXISTING

55.99 LF

@ 0.61%

12" CMP

EX G

AS S

ERVIC

E-NO

LO

CATE

FIEL

D V

ERIF

YSTA

: 30+

56.8

1T.

O.P

.=5234.5

7

SAN SERVICESTA: 25+64.67

T.O.P.=5221.49 SAN S

ERVIC

E

STA

: 28+

26.6

9T.

O.P

.=5222.6

1

SAN S

ERVIC

E

STA

: 28+

84.0

9T.

O.P

.=5222.9

7

SAN S

ERVIC

ESTA

: 28+

98.8

0T.

O.P

.=5223.1

2

5 YEAR HGL

Q(5)=373 CFS

Q(FULL)=404 CFS

Q(5)=372 CFS

Q(FULL)=395 CFS

Q(5)=370 CFS

Q(FULL)=420 CFS

493.0 LF @ 0.30%

24" PVC

459.1 LF @ 0.30%

24" PVC

REMOVE EX 84" PRECAST PLUG

AND CONNECT 84" RCP STORM

STA: 24+78.03

RIM = 5231.58

84" INV. IN = 5223.37 (S)

84" INV. OUT = 5223.37 (N)

EX F

O Q

WES

T CO

NC C

AP

13 T

O T

OP

36 T

O B

OTT

OM

STA

: 24+

65.8

7T.

O.P

.=5235.3

9

EX 8" GASSTA: 24+85.22T.O.P.=5232.29

EX 6

" GAS

STA

: 24+

93.8

1T.

O.P

.=5233.4

9'

PR

OT

EC

T

EX 4

" GAS

STA

: 27+

75.4

4T.

O.P

.=5234.7

3'

PR

OT

EC

T

EX 2

" GAS

STA

: 28+

96.3

2T.

O.P

.=5236.1

2'

PR

OT

EC

T

EX 6

" GAS

STA

: 31+

24.8

3T.

O.P

.=5236.7

1'

PR

OT

EC

T

EX 6

" GAS

STA

: 32+

56.2

2T.

O.P

.=5238.0

6'

PR

OT

EC

T

EX 2

" GAS

STA

: 32+

67.6

6T.

O.P

.=5238.5

3'

PR

OT

EC

T

EX 2" D.I.P WTR

EX W

AT

SER

VCIE

STA

: 29+

49.0

1T.

O.P

.=5233.1

8'

PR

OT

EC

T

XX STA

: 33+

93.8

4T.

O.P

.=5238.7

1'

PR

OT

EC

T

CONTRACTOR SHALL SURVEY AND

CONFIRM INVERT WITH ENGINEER

5215

5220

5225

5230

5235

5240

5245

5250

5215

5220

5225

5230

5235

5240

5245

5250

24+50 25+00 26+00 27+00 28+00 29+00 30+00 31+00 32+00 33+00 34+00

9 OF 17

MAY 2016

D-04-323-STM-01.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

ST

OR

M P

LA

N &

P

RO

FILE

25+

50.00 T

O 34+

00.00

N

STORM PLAN & PROFILE 25+50.00 TO 34+00.00

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

NOTES:

1. THE CITY OF DENVER ASSUMES NO

RESPONSIBILITY FOR EXISTING UTILITY

LOCATIONS. THE UTILITIES SHOWN ON THIS

DRAWING HAVE BEEN PLOTTED FROM THE BEST

AVAILABLE INFORMATION. IT IS, HOWEVER, THE

CONTRACTOR'S RESPONSIBILITY TO FIELD

VERIFY THE LOCATION OF ALL UTILITIES PRIOR

TO THE COMMENCEMENT OF ANY

CONSTRUCTION.

2. STORM SEWER PIPE LENGTHS ARE TWO

DIMENSIONAL LENGTHS. LENGTHS ARE CENTER

TO CENTER BETWEEN MANHOLES AND TO INSIDE

OF BOX FOR INLETS.

3. STORM SEWER LENGTHS WITH FLARED END

SECTIONS ARE TO END OF FLARED END SECTION.

4. STORM SEWER MAIN SHALL BE ASTM C-76 CLASS

III PIPE UNLESS OTHERWISE NOTED.

AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
121'
AutoCAD SHX Text
T
AutoCAD SHX Text
230'
AutoCAD SHX Text
T
AutoCAD SHX Text
125'
AutoCAD SHX Text
T
AutoCAD SHX Text
170'
AutoCAD SHX Text
T
AutoCAD SHX Text
227'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
TC
AutoCAD SHX Text
TH#5
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
E
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 9: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

ST

MS

TM

ST

M

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

G

G ABAN G ABANG ABAN G ABAN

G ABAN G ABANG ABAN G ABAN

G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABANG ABAN

G ABANG ABAN

S

A

N

S

A

N

SA

NS

AN

S

A

N

S

A

N

S

A

N

S

A

N

S

A

N

SAN

S

A

N

S

A

N

S

A

N

S

A

N

S

A

N

SAN

SAN

SAN

SAN

SA

N

SAN SAN SAN SAN SAN SAN

SA

N

SA

N

G A

BA

N

FIBER OPTIC CABINET

F

O

A

B

A

N

F

O

A

B

A

N

EX CABLE

W

EX OHE

EX

O

HE

EX

O

HE

EX

O

HE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHEEX OHE

EX OHEEX OHE

EX OHEEX OHE EX OHE EX OHE EX OHE EX OHE EX OHE EX OHE EX OHE EX OHE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

EX

O

HE

W

W

W

W

W

W

X X X X X X X X X X

XX

X X

XX

X X X X X X X X

XXXXXXXXXXXXXXXXXXX

X

X

X

W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABANW ABAN W ABAN W ABAN

W A

BA

N

W ABAN

W ABAN

FO

A

BA

N

T

T

M

M

T

FO

FO

FO

W

W

W

W

W

W

FO

FO

W

FO

FOFO

FO

FOFO

F

O

G

G

FO

FO

FOFO

FOFO

FO

FO

W

W

WW

WW

WW

WW

WW

W

W

W

FO

FO

FO

FO

FO F

O

FO

FO

FO

FO

FOFO

F

O

F

O

FO

FO

FO

FO

FOFO

W

W

FO

FO

FO

FO

FO

FO

FO

FO

FO FO

W

W

WW

WW W

W

S

A

N

S

A

N

FO

FO

FO

FO

FO

G

FO

FO

FO

FO

FO

FO

G ABAN

G ABAN

G ABAN

G ABAN

GG

G

G

G

G

G

G

G

G

G

G

GG G

GG G G

G G G G

G

W A

BA

N

W A

BA

N

KB-4

KB-5

34+00

35+00

36+00

37+00

38+00

39+0040+00 41+00 42+00 43+00

70

.5

3'

R.O

.W

.

65

.5

3'

R.O

.W

.

EX POWERPOLE (TYP)

EX 6" GAS MW

EX FIBER OPTIC(AIRTOUCH)

EX COMCAST TV

PROTECT

EX FIBER OPTICEX TELEPHONE

EX 6" GAS MW

STM MH-B11 (TYPE B)

STA 39+39.30, 0.00'

N=3397.6691

E=7494.6605

STM MH-B10 (TYPE B)

STA 34+39.21, 0.00'

N=3897.6972

E=7502.2413

422.8 LF

84" RCP

500.1 LF

84" RCP

EX TAP

(TYP)

END PIPE JACKING

INSTALL TRANSITION PIPE FROM

CLASS SN 182 TO CLASS SN 46

(TO BE INCLUDED IN CLASS SN 46

PIPE COST AND QUANTITY)

STA=38+13.02

OFF=0.00

N=3523.93

E=7496.57

S89° 35' 31.02"W

2483.33

LAND LINE

N00° 07' 28.98"W

2648.64

RANGE LINE

N00° 00' 21.30"W

1760.64

EX 6" GAS MW

TO BE RELOCATED

BY XCEL - CONTRACTOR

TO COORDINATE

CONTACT WAYNE GALLEGOS

(303) 571-6632

TVP-147

APPROXIMATELY 341 LF OF

EX 12" WATER UNDER I-70 AND

PARALLEL TO PROPOSED STORM

PIPE JACKING TO REMAIN IN PLACE.

THE NEW 12" WATER WILL CONNECT

TO THIS 341 LF OF EXISTING 12" WATER.

EX SAN MH 6 4'ØREMOVE AS

NECESSARY

EX SAN MH 5 4'Ø

REMOVE AS NECESSARY

PROPOSED 341 LF OF

84" RPMP* (SN 182) WITH

STEEL BY JACKING

EX 4" C.I. WAT

30.87 LF

6" PVC WAT

EX FIBER OPTIC(AIRTOUCH)

STORM-5

(SEE SHEET #)

EXISTING ADESTA, LLC LEASED TO ABOVE NET FIBER OPTICS CONDUIT. CONDUIT IS

ABANDONED ACCORDING TO OWNER. CONTRACTOR TO FIELD LOCATED AND VERIFY

FIBER OPTIC CONDUIT IS ABANDONED. PRIOR TO CONSTRUCTION. IF NOT ABANDONED,

TO BE RELOCATED BY OWNER.

ADESTA LLC DUKE HORAN, (303)-585-8087, ([email protected])

ABOVE NET, INC, DAN FORD, (480)-252-6203, ([email protected])

EXISTINGLIGHT(TYPICAL)

EXISTINGOVERHEADELECTRIC(TYPICAL)

PROJECT BENCH MARK

CCD BM 445 BRASS CAP IN TOP OF CURB

SOUTHEAST CORNER OF DAHLIA ST

AND STAPLETON DRIVE SOUTH

ELEVATION=5247.10

DATUM NGVD 29

EXISTING OVERHEAD POWER.

CONTRACTOR SHALL PROTECT.

IF UNABLE CONTRACTOR TO

COORDINATE RELOCATION WITH XCEL.

CONTACT WAYNE GALLEGOS

(303) 571-6632

PROTECT

EX FIBER

OPTIC

PROTECT

6" WATER

15" STORM TO

REMAIN. CONTRACTOR

SHALL PROTECT

CONTRACTOR TO PROTECT

EXISTING 5' WALK AND CURB

AND GUTTER . (TYPICAL)

PROTECT EXISTING STORM

EX 12" WATER IN DAHLIA WAS RELOCATED AND

ABANDONED IN PARKHILL STORM PH IV-A.

CONTRACTOR TO REMOVE ABANDONED 12"

WATER AS NECESSARY TO INSTALL 84" STORM.

COST OF REMOVAL TO BE INCLUDED IN COST OF

84" STORM PIPE

CONTRACTOR TO PROTECT

EXISTING 5' WALK AND CURB

AND GUTTER . (TYPICAL)

MA

TC

HL

IN

E 34+

00

MA

TC

HL

IN

E 43+

00

AD

D A

LT

. 1

AD

D A

LT

. 2

BEGIN PIPE JACKING

INSTALL TRANSITION PIPE FROM CLASS SN 46

TO CLASS SN 182 (TO BE INCLUDED IN

CLASS SN 182 PIPE COST AND QUANTITY)

STA=34+72.02

OFF=0.00

N=3864.89

E=7501.74

EX FIBER OPTIC (ADESTA)CCD COULD NOT LOCATE AT APPROX 22' DEPTH

CONTRACTOR TO FIELD VERIFY LOCATION AND SIZE

PRIOR TO CONSTRUCTION

DUKE HORAN, (303)-858-8087, ([email protected])

EX 18" SANEX 18" SAN

EX 18" SANREMOVE AS NECESSARY

EX 18" SANREMOVE AS

NECESSARY

EX 18" S

AN

EX 1

2" S

AN

N DAHLIA STREET

STA

PLET

ON

DR

. S.

INTE

RST

ATE

-70

(ELE

VA

TED

)

STA

PLET

ON

DR

. N.

BA

SE

B

ID

AD

D A

LT

. 1

EX SANITARYABANDONED

KB-4

KB-5

WC=7.2DD=114.9+4=0-200=35LL=18NPA-2-4 (0)

WC=17.4DD=110.1-200=53LL=34PI=17A-6 (6)

WC=13.4DD=109.8+4=0-200=48LL=31PI=16A-6 (4)

WC=9.1DD=118.9

WC=2.6DD=110.7+4=2-200=5NVNPA-1-b (1)5220

5225

5230

5235

5240

5245

5250

5255

5220

5225

5230

5235

5240

5245

5250

5255

34+00 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 43+0043+00

422.8 LF @ 0.30%

84" RCP

ST

M M

H-B

11 (T

YP

E B

)

ST

A: 39+

39.30

RIM

=

5247.48

84" IN

V. IN

=

5228.16 (S

)

84" IN

V. O

UT

=

5227.96 (N

)

18" IN

V. IN

=

5237.47 (E

)

18" IN

V. IN

=

5237.47 (W

)

ST

M M

H-B

10 (T

YP

E B

)

ST

A: 34+

39.21

RIM

=

5244.60

84" IN

V. IN

=

5226.46 (S

)

84" IN

V. O

UT

=

5226.26 (N

)

EX 3

" GAS

STA

: 42+

81.6

6T.

O.P

.=5246.8

4

EX 6" FOSTA: 38+25.68T.O.P.=5243.13

EX 12" STMSTA: 35+39.50T.O.P.=5242.96

EX W

AT

FIEL

D V

ERIF

Y(A

SSUM

ED T

.O.P

.)STA

: 39+

09.4

6T.

O.P

.=5242.8

0

EX F

O P

HO

NE

4-4

"STA

: 34+

85.0

7T.

O.P

.=5242.6

6

EX 6" WAT FIELD VERIFY(ASSUMED T.O.P.)

STA: 38+21.89T.O.P.=5242.30

EX 12" WATSTA: 37+84.56

T.O.P.=5241.38

EX 4" GASSTA: 35+09.59T.O.P.=5240.86

EX 12" WATSTA: 34+94.87T.O.P.=5239.17

EX FO - NO LOC@ 22+' DOWNCONTRACTOR

TO FIELD LOCATESTA: 37+49.10

T.O.P.=FIELD LOCATE

29.36 LF

@ 1.00%

EX 18" SAN

18.4 LF

@ 1.48%

12" PVC

19.4 LF

@ 2.00%

12" PVC

16.7 LF

@ 1.97%

18" PVC

54.5 LF

@ 1.05%

15" RCP STM

EXISTING GROUND

AT CL OF PIPE

EX FO (NO LOCATE)FIELD VERIFY

STA: 34+22.33T.O.P.=5239.25

℄ STA= 34+72.02

BEGIN JACKING

℄ STA= 38+13.02

END JACKING

PROPOSED 341 LF OF

84" RPMP* (SN 182)

BY JACKING

EX 1

0" W

AT(

CI F

IRE)

STA

: 42+

04.6

6T.

O.P

.=5243.4

7

EX W

AT

(NO

LO

CATE

)FI

ELD

VER

IFY

STA

: 42+

54.0

5T.

O.P

.=5244.1

1

500.1 LF @ 0.30%

84" RPMP*

2-12" FO (ABOVE NET)TOP=88"BOT=118"STA: 38+15.19T.O.P.=5239.87

5 YEAR HGL

Q(5)=370 CFS

Q(FULL)=605 CFS

Q(5)=367 CFS

Q(FULL)=404 CFS

295.83 LF

@ 0.25%

EX 12" SAN

118.3 LF @ 0.30%

24" PVC

213.4 LF @ 0.31%

24" PVC

206.4 LF @ 0.29%

24" PVC

331.8 LF @ 0.30%

21" PVC

*REINFORCED POLYMOR MORTOR PIPE

EX 12" WAT FIELD VERIFY(ASSUMED T.O.P.)STA: ???T.O.P.=5241.39

2" D

.I.P.

SER

VIC

ENO

LO

CATE

STA

: ??

?

EX 4

" GAS

STA

: 35+

01.4

5T.

O.P

.=5242.4

8'

PR

OT

EC

T

EX 2

" GAS

STA

: 38+

24.8

6T.

O.P

.=5244.0

2'

PR

OT

EC

T

EX 2

" GAS

STA

: 41+

49.1

5T.

O.P

.=5245.1

6'

PR

OT

EC

T

10 OF 17

MAY 2016

D-04-323-STM-01.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

ST

OR

M P

LA

N &

P

RO

FILE

34+

00.00 T

O 43+

00.00

N

STORM PLAN & PROFILE 34+00.00 TO 43+00.00

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

NOTES:

1. THE CITY OF DENVER ASSUMES NO RESPONSIBILITY FOR

EXISTING UTILITY LOCATIONS. THE UTILITIES SHOWN ON

THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST

AVAILABLE INFORMATION. IT IS, HOWEVER, THE

CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE

LOCATION OF ALL UTILITIES PRIOR TO THE

COMMENCEMENT OF ANY CONSTRUCTION.

2. STORM SEWER PIPE LENGTHS ARE TWO DIMENSIONAL

LENGTHS. LENGTHS ARE CENTER TO CENTER BETWEEN

MANHOLES AND TO INSIDE OF BOX FOR INLETS.

3. STORM SEWER LENGTHS WITH FLARED END SECTIONS

ARE TO END OF FLARED END SECTION.

4. STORM SEWER MAIN SHALL BE ASTM C-76 CLASS III PIPE

UNLESS OTHERWISE NOTED.

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
208'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
T
AutoCAD SHX Text
23'
AutoCAD SHX Text
T
AutoCAD SHX Text
TH#6
AutoCAD SHX Text
TH#7
AutoCAD SHX Text
TH#8
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
T
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 10: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

STM

STM

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G A

BA

N

W

G ABAN G ABAN G ABANG ABAN

G ABAN

G ABAN

G ABANG ABAN

G ABANG ABAN

G ABANG ABAN G ABAN

G ABANG ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

SAN SAN

SA

N

SA

N

SANSAN SAN

SAN SANSAN

SANSAN

SANSAN

SANSAN

SA

N

SAN SAN SAN SAN

S

A

N

SANSAN

S

A

N

S

A

N

S

A

N

G A

BA

N

FO

A

BA

N

T

T

T

T

T

T

T

T

T

T

F

O

A

B

A

N

F

O

A

B

A

N

EX OHE

EX OHE

EX OHE

EX OHEEX OHE

EX OHEEX OHE

EX OHEEX OHE

EX OHEEX OHE

EX OHEEX OHE

EX OHE EX OHE EX OHE

EX OHE

EX OHE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

S

A

N

S

T

M

S

T

M

S

T

M

S

A

N

FO

AB

AN

FO ABANFO ABAN

FO

AB

AN

G

WW

W

A

B

A

N

W

A

B

A

N

W

A

B

A

N

W

A

B

A

N

W

A

B

A

N

W A

BA

N

W

W

W

X

X

X

X

X X X XX X X X X X X X X X X X X X X X X

XX

XX

X

XXXX

W ABANW ABAN

W ABANW ABAN

W ABANW ABAN W ABAN

W ABANW ABAN

W ABAN W ABAN W ABAN W ABANW ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN

W ABANW ABAN W ABAN

W

A

B

A

N

W ABAN

G

FOFO

FOFO

FO FO

FO

FOFO

FOFO

FO

FO FO

FO

FO

FO

W

W

W

W

WW

W

W

W

W

FOFO

FO

FO

FOFO

FOFO

FO FO

FO

FO

FOFO

FO FO

WW

EE

E

E

G

G

G

G

G

G

G

FOF

O

FO

FO

FO

F

O

F

O

F

O

F

O

FO

FO

W W

W

W

W

W

WW W

F

O

F

O

F

O

F

O

E

E

G

G

FO

FO

F

O

F

O

F

O

W

E

E

E

E

E

E

FO

FO

FO

FO

FO

FO

FO

FO

WW

WW

WW

WW

FO

FO

FO

FO

G G GG

G

G

G GG

G G G

GG G

G

G

G

G

G

G

KB-6

KB-7

KB-8

S

7

9

°5

4

'3

2

.0

9

" E

S

7

9

°5

4

'3

2

.0

9

" E

S

T

3

0

1

+

1

4

.3

9

S

T

3

0

0

+

9

8

.7

2

E

X=660620.7520Y=454694.3368

X=660629.1543Y=454744.6359

X=660641.7492Y=454739.4040

X=660597.7297Y=454556.4515

X=660590.0017Y=454510.1187X=660590.0017Y=454510.1187X=660590.0017Y=454510.1187X=660590.0017Y=454510.1187

X=660637.0491Y=454500.1364

X=660724.8176Y=454740.5581

X=660573.1129Y=454560.8118

X=660565.5239Y=454515.3123

W

W

43+0044+00 45+00 46+00 47+00 48+00

49+00

50+

00

51+

00

52+

00

53+00

70

.5

3'

R.O

.W

.

44

'1

3'

13

'

EX POWERPOLE (TYP)

EX POWERPOLE (TYP)

EX 6" GAS MW

EX FIBER OPTIC(AT&T)

PROTECT

EX FIBER OPTIC(QWEST)

STM MH-B12 (TYPE B)

STA 43+62.13, 0.00'

N=2974.8323

E=7494.1379

EX STM MH-2 (PRIV)STA 43+63.28, -146.43' LN=2974.3122E=7640.5747

EX STM MH (PRIV)STA 43+62.52, -48.51' LN=2974.6600E=7542.6455

97

.9 L

F2

7" R

CP

21

5.1

LF

27

" RC

PEX TAP(TYP)

END PIPE JACKING

STA=52+01.14

OFF=0.00

N=2136.56

E=7472.92

PROPOSED 251.22 LF OF

84" RCP CLASS V W/ STEEL

END RINGS BY JACKING

PER UNION PACIFIC SPECIFICATIONS

N00° 07' 28.98"W

RANGE LINE

N00° 07' 28.98"W

2648.64

RANGE LINE

N00° 00' 21.30"W

1760.64

S8

9° 3

5' 1

4.8

1"W

15

16

.0

0

BY XCEL - CONTRACTOR

CONTACT WAYNE GALLEGOS

EX 10" CI FIRE LINE

CONSTRUCT NEW 4' DIA.

STM MH OVER EX 27" STM

ABANDON EX 27" STM EAST

OF NEW STM MH

EX SAN MH 1 4'ØTO BE REMOVED

EX FIBER OPTIC (VERIZON) CONTRACTOR SHALL CALL

VERIZON PRIOR TO CONSTRUCTION

(DAVID SZABLOWSKI 303-901-7506)

EX FIBER OPTIC

(LEVEL 3)

EX 12" WATER ABOVE PROPOSED 84" RCP

STORM PIPE JACKING IS ABANDONED.

CONTRACTOR TO VERIFY

EX FIBER OPTIC (QWEST)

ISOLATE EX 12" WATER AS NECESSARY

TO INSTALL 84" RCP STORM PIPE.

SEE WATER PLANS FOR DETAILS

EX 12" CI WAT

CONTRACTOR TO PROTECT EXISTING

AT&T FIBER OPTICS LINE IF POSSIBLE.

EX FIBER OPTIC TO BE RELOCATED

BY (AT&T) IF NECESSARY

EX SAN MH 2 4'ØTO BE REMOVED

TVP-149

LAND LINE

N00° 07' 28.98"W

2648.64

TVP-100

E

X

1

2

" W

A

T

E

X

1

0

" G

A

S

E

X

2

1

" S

A

N

E

X

1

0

" G

A

S

E

X

3

6

" S

T

M

EX 10" SAN (ABANDONED)

RAILROAD CROSSINGCL STA: 50+76.57

PERMIT-FOLDER# 2599-97

PLUG AND ABANDON EX 36"

STM WEST TO NEXT STORM

MH PER CCD SPECIFICATIONS.

(APPROXIMATELY 400' +-)

E

X

1

2

" W

A

T

CONTRACTOR SHALL MAINTAIN ACCESS TO SAFEWAY DAHLIA GATE, (ADDRESS 4350/4500 NORTH DAHLIA ST.) AT ALL TIMES.

ONE LANE OF TRAFFIC FROM THE SAFEWAY DAHLIA GATE TO THE SAFEWAY PROPERTY DIRECTLY WEST, (ADDRESS 4600 E.

STAPLETON DRIVE SOUTH AND 4200 THRU 4600 E. 46TH AVE.) SHALL BE MAINTAINED AT ALL TIMES. DURING CONSTRUCTION

FROM APPROXIMATE STATION 38+09 TO APPROXIMATE STATION 44+28, LOCAL TRAFFIC ONLY WILL BE DETOURED TO ENTER

SAFEWAY DAHLIA GATE FROM THE SOUTH. DURING CONSTRUCTION FROM APPROXIMATE STATION 44+28 TO APPROXIMATE

STATION 52+02, LOCAL TRAFFIC ONLY WILL BE DETOURED TO ENTER SAFEWAY DAHLIA GATE FROM THE NORTH. TRAFFIC

CONTROL SIGNAGE SHALL IDENTIFY ADDRESSES TO DIRECT LOCAL TRAFFIC ONLY.

CONTRACTOR SHALL CONTACT LORI BIETZ, (SAFEWAY) @ (303) 316-3242 TO LOCATE PRIVATE COMMUNICATION LINES

CROSSING DAHLIA STREET AT APPROXIMATE ADDRESS OF 4500 NORTH DAHLIA STREET PRIOR TO CONSTRUCTION.

CONTRACTOR SHALL CONTACT RICK RUTTELL, (SAFEWAY MAINTENANCE MANAGER) @ (303) 320-8966 PRIOR TO BEGIN

CONSTRUCTION IN DAHLIA STREET.

COST TO BE INCLUDED IN TRAFFIC CONTROL.

EXISTINGLIGHT(TYPICAL)

EXISTINGOVERHEADELECTRIC(TYPICAL)

EX 1

5" S

AN

EX SAN MH - (389) 4'Ø

EX 12" WATER INSTALLED BY FASTRACKS

IN SUMMER OF 2011.

CONTRACTOR TO VERIFY

PROTECT EXISTING

QWEST FIBER

OPTIC VAULT

PROTECT

EX GAS SERVICE

EXISTING OVERHEAD POWER.

CONTRACTOR SHALL PROTECT.

IF UNABLE CONTRACTOR

TO COORDINATE

RELOCATION WITH XCEL.

CONTACT WAYNE GALLEGOS

(303) 571-6632

CONTRACTOR TO PROTECT

WATER (TYPICAL)

CONTRACTOR

TO PROTECT

WATER

CONTRACTOR TO

PROTECT WATER

EXISTING

12" GAS

(INSTALLED

MARCH 2012)

7.1

6'

5.4

4'

5.2

3'

CONTRACTOR TO PROTECT

EXISTING 5' WALK AND CURB

AND GUTTER . (TYPICAL)

EX 12" WATER IN DAHLIA WAS RELOCATED AND

ABANDONED IN PARKHILL STORM PH IV-A.

CONTRACTOR TO REMOVE ABANDONED 12"

WATER AS NECESSARY TO INSTALL 84" STORM.

COST OF REMOVAL TO BE INCLUDED IN COST OF

84" STORM PIPE

CONTRACTOR TO PROTECT

EXISTING 5' WALK AND CURB

AND GUTTER . (TYPICAL)

MA

TC

HL

IN

E 43+

00

MA

TC

HL

IN

E 52+

25

E

T

U

U

U

U

T

T

U

UU

U

RAILROAD CROSSINGCL STA: 51+28.37

RAILROAD CROSSINGCL STA: 51+43.49

AD

D A

LT

. 2

PH

AS

E V

B

STM

EX 15" SAN

TO BE ABANDONED

EX 18" SAN

EX 18" SAN

EX 18" SANTO BE REMOVED

AS NECESSARY

EX 18" SANTO BE REMOVED

AS NECESSARY

N DAHLIA STREET

SMIT

H R

OA

D

UN

ION

PA

CIF

IC R

R

RTD

EA

STLI

NE

PROTECT EXISTING

DRIVEWAY BOTH

SIDES OF ROAD

EX 6" GAS MWTO BE RELOCATED BY XCEL -

CONTRACTOR TO COORDINATE

CONTACT WAYNE GALLEGOS

(303) 571-6632

KB-6

KB-7

WC=10.3DD=115.9-200=38LL=30PI=15A-6 (2)

WC=3.4DD=108.3+4=8-200=7LL=20PI=1A-1-b (0)

WC=13.5DD=112.3-200=60LL=26PI=13A-6 (5)

WC=18.9DD=108.4-200=62LL=40PI=20WSS=0.00A-6 (10)

WC=5.0DD=106.8+4=0-200=12NVNPA-2-4 (0)

WC=6.8DD=117.5-200=16NVNPWSS=0.00A-2-4 (0)

5225

5230

5235

5240

5245

5250

5255

5260

5225

5230

5235

5240

5245

5250

5255

5260

43+00 44+00 45+00 46+00 47+00 48+00 49+00 50+00 51+00 52+00 53+00

EXIST

215.1 LF

@ 0.53%

27" RCP

ST

M M

H-B

12 (T

YP

E B

)

ST

A: 43+

62.13

RIM

=

5250.73

IN

V. IN

=

5229.63 (S

)

EX

IN

V. IN

=5239.17

IN

V. O

UT

=

5229.43 (N

)

EX

IN

V. IN

=5239.17

EX 2" GASSTA: 48+09.97

T.O.P.=5252.42EXISTING GROUND

AT CL OF PIPE

SAN SERVICESTA: 45+19.12

T.O.P.=5233.16

EX F

O (NO

PO

THO

LE)

ASSUM

ED T

.O.P

.STA

: 4

5+

04

.16

T.O

.P.=

52

48

.00

26.08 LF

@ 0.96%

EX 15" SAN

TO BE

ABANDONED

435.2 LF @ 0.30%

84" RCP

EX LEVEL 3

FIBER OPTIC

TO BE RELOCATED

BY LEVEL 3

5 YEAR HGL

Q(5)=347 CFS

Q(FULL)=404 CFS

Q(5)=347 CFS

Q(FULL)=404 CFS

500.3 LF @ 0.30%

21" PVC

2

3

.

2

L

F

@

4

.

3

1

%

2

1

"

P

V

C

40.85 LF

10" D.I.P. WAT

60.13 LF

6" D.I.P. WAT

61.98 LF

2" D.I.P WAT

48.47 LF

10" D.I.P. WAT

RAIL

RO

AD

CRO

SSIN

GC

L STA

: 5

1+

43

.49

RAIL

RO

AD

CRO

SSIN

GC

L STA

: 5

1+

28

.37

RTD EASTLINEUNION PACIFIC

EX 10" D.I.P. WTR

EX 6" D.I.P. WTR

RAIL

RO

AD

CRO

SSIN

GC

L STA

: 5

0+

56

.18

RAIL

RO

AD

CRO

SSIN

GC

L STA

: 5

0+

76

.57

℄ STA= 49+59.26

BEGIN JACKING

℄ STA= 52+05.46

END JACKING

PROPOSED 246 LF OF

84" RCP CLASS V W/ STEEL

END RINGS BY JACKING

PER UNION PACIFIC SPECIFICATIONS

EX 12" WAT

(ABANDONED)

Q(5)=347 CFS

Q(FULL)=404 CFS

ST

M M

H-B

13 (T

YP

E B

)

ST

A: 47+

97.29

RIM

=

5254.25

84" IN

V. O

UT

=

5230.93 (N

)

84" IN

V. IN

=

5231.13 (S

)

FU

TU

RE

ST

M M

H-B

14 (T

YP

E B

)

ST

A: 49+

54.49

RIM

=

5255.83

84" IN

V. O

UT

=

5231.61 (N

)

84" IN

V. IN

=

5231.81 (S

)

FU

TU

RE

ST

M M

H-B

15 (T

YP

E B

)

ST

A: 52+

30.62

RIM

=

5255.62

33" IN

V. IN

=

5248.43 (S

)

33" IN

V. O

UT

=

5248.43 (N

)

84" IN

V. O

UT

=

5232.64 (N

)

84" IN

V. IN

=

5232.84 (S

)

EX 12" STMSTA: ???T.O.P.=5251.60

EX F

O P

HO

NE

2-4

"STA

: ??

?T.

O.P

.=5

25

2.5

2

EX 10" GASSTA: ???

T.O.P.=5250.93 EX 12" STMSTA: ???T.O.P.=5253.25

EX 12" WATSTA: ???T.O.P.=5249.29

EX FO 2-2"STA: ???

T.O.P.=5252.08

EX 12" WATSTA: ???

T.O.P.=5250.41

PIPE CLOSURE (CCD)

STA: 52+05.71

RIM = 5240.73

84" INV. OUT = 5232.56 (N)

84" INV. IN = 5232.56 (S)

XX STA

: 4

9+

48

.62

T.O

.P.=

52

50

.90

'X

X

EX 2" D.I.P WTR

157.2 LF @ 0.30%

FUTURE 84" RCP

251.2 LF @ 0.30%

FUTURE 84" RCP

11 OF 17

MAY 2016

D-04-323-STM-01.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

ST

OR

M P

LA

N &

P

RO

FILE

43+

00.00 T

O 52+

00

N

STORM PLAN & PROFILE 43+00.00 TO 52+00

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

CONTRACTOR SHALL COORDINATE WITH

RTD-FASTRACKS AT SMITH ROAD AND

DAHLIA STREET FOR ALL CONSTRUCTION

ON DAHLIA STREET. DAHLIA STREET

SOUTH OF I-70 CAN NOT BE CLOSED AT

THE SAME TIME DAHLIA STREET NORTH OF

I-70 IS CLOSED OR AT THE SAME TIME AS

HOLLY STREET IS CLOSED.

CONTACT JESSE GROSS FASTRACKS

(303) 837-2603 WORK

(720) 334-3583 CELL

[email protected]

NOTES:

1. THE CITY OF DENVER

ASSUMES NO RESPONSIBILITY

FOR EXISTING UTILITY

LOCATIONS. THE UTILITIES

SHOWN ON THIS DRAWING

HAVE BEEN PLOTTED FROM

THE BEST AVAILABLE

INFORMATION. IT IS,

HOWEVER, THE

CONTRACTOR'S

RESPONSIBILITY TO FIELD

VERIFY THE LOCATION OF ALL

UTILITIES PRIOR TO THE

COMMENCEMENT OF ANY

CONSTRUCTION.

2. STORM SEWER PIPE LENGTHS

ARE TWO DIMENSIONAL

LENGTHS. LENGTHS ARE

CENTER TO CENTER

BETWEEN MANHOLES AND TO

INSIDE OF BOX FOR INLETS.

3. STORM SEWER LENGTHS

WITH FLARED END SECTIONS

ARE TO END OF FLARED END

SECTION.

4. STORM SEWER MAIN SHALL

BE ASTM C-76 CLASS III PIPE

UNLESS OTHERWISE NOTED.

AutoCAD SHX Text
P&C
AutoCAD SHX Text
P&C
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
222'
AutoCAD SHX Text
T
AutoCAD SHX Text
310'
AutoCAD SHX Text
TC
AutoCAD SHX Text
P&C
AutoCAD SHX Text
P&C
AutoCAD SHX Text
TH #10
AutoCAD SHX Text
TH #9
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
E
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
E
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 11: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

SA

NS

AN

T

G ABAN

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

W

W A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

N

M

M

FO

FO

W

W

G

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

F

O

FO

FO

FO

FO

FO

WW

WW

WW

W

W

W

G A

BA

N

G A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

N

GG

GG

GG

GG

G

G

W ABAN

28+

00

29+

00

30+

00

31+

00

SA

N

80'

R.O.W.

23.13'

N D

AH

LIA

ST

44' 18'18'

EX POWER

POLE (TYP)

RAIL ROAD CROSSING

CL STA: 28+51.11

RAIL ROAD CROSSING

CL STA: 28+81.09

STM MH-B8 (MH TEE)

STA 29+54.36, 0.00'

N=4382.5512

E=7501.1478

EX 12" CI WAT (1955)

BEGIN PIPE JACKING

STA=31+42.02

OFF=0.00

N=4194.88

E=7501.57

318.47 LF

84" RCP

0+00 1+00

SINGLE TYPE 16 INLET B-8.1

STA 0+30.83, 0.00' R

N=4382.5379

E=7476.6846

24.46 LF

18" RCP

19.53 LF

18" RCP

STORM-3

20.99'

33.66'

37.5'

19.13'

14.26'

21.5'

PROTECT EXISTING

12" PVC

PROTECT

1" COPPER

12" PVC

SEE WATER PLANS

FOR DETAILS

EX CROSS PAN

TO BE REMOVED AND

REPAVED W/ AC WITH

CROWN CROSS SECTION

SINGLE TYPE 16 INLET B-8.2

STA 29+54.42, -19.53' L

N=4382.5372

E=7520.6814

PROTECT EX AT&T F.O. - IF UNABLE

TO PROTECT CONTRACTOR

TO COORDINATE WITH

IAN WETTELAND (303) 324-6001 AND

TOM JAKSE (720) 289-5471

PROTECT EXISTING

FIBER OPTIC/TELE.

(TYPICAL)

PROTECT EXISTING

O.H. ELECTRIC

(TYPICAL)

S

T

M

G ABAN

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

E

X

O

H

E

E

X

O

H

E

W A

BA

NW

A

BA

NW

A

BA

NW

A

BA

N

W A

BA

N

W A

BA

N

T

G

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

WW

W

WW

W

W

W

W

W

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

G A

BA

N

GG

G

GG

G

G

GG

G

W ABAN

31

+0

03

2+

00

33

+0

0

80'

R.O.W.

N D

AH

LIA

ST

44' 18'18'

EX POWER

POLE (TYP)

EX TELEPHONE

VAULT

RAIL ROAD CROSSING

CL STA: 32+28.55

RAIL ROAD CROSSING

CL STA: 31+72.94

166.38 LF

84" RCP

END PIPE JACKING

STA=32+62.02

OFF=0.00

N=4074.89

E=7501.84

BEGIN PIPE JACKING

STA=31+42.02

OFF=0.00

N=4194.88

E=7501.57

318.47 LF

84" RCP

STM MH-B9 (MH TEE)

STA 32+72.83, 0.00'

N=4064.0791

E=7501.8660

0+00

0+80

SINGLE TYPE 16 INLET-B9.1

STA 0+17.76, 0.00'

N=4064.2571

E=7477.1223

24.74 LF

18" RCP

19.69 LF

18" RCP

SINGLE TYPE 16 INLET B9.2

STA 0+62.19, 0.00'

N=4063.9023

E=7521.5564

STORM-4

PROTECT

EX TELEPONE (QWEST)

S

T

M

12" PVC

PROTECT 12" PVC

PROTECT EXISTING

12" PVC

12" PVC

SEE WATER PLANS

FOR DETAILS

12" PVC

PROTECT

EX AT&T VAULT

PROTECT EX AT&T F.O. - IF UNABLE

TO PROTECT CONTRACTOR

TO COORDINATE WITH

IAN WETTELAND (303) 324-6001 AND

TOM JAKSE (720) 289-5471

(TYPICAL)

PROTECT EXISTING

O.H. ELECTRIC

(TYPICAL)

5220

5225

5230

5235

5240

5245

5250

5255

5220

5225

5230

5235

5240

5245

5250

5255

0+00 1+00

SIN

GLE

T

YP

E 16 IN

LE

T B

-8.1

ST

A: 0+

30.83

RIM

=

5238.10

18" IN

V. O

UT

=

5233.22 (E

)

24.46 LF

@ 9.76%

18" RCP

ST

M M

H-B

8 (M

H T

EE

)

ST

A: 29+

54.36

RIM

=

5238.68

84" IN

V. IN

=

5224.80 (S

)

84" IN

V. O

UT

=

5224.80 (N

)

18" IN

V. IN

=

5230.83 (W

)

18" IN

V. IN

=

5230.83 (E

)

19.53 LF

@ 5.47%

18" RCP

493.0 LF

@ 0.30%

24" PVC SAN

SIN

GLE

T

YP

E 16 IN

LE

T B

-8.2

ST

A: 29+

54.42

RIM

=

5238.30

18" IN

V. O

UT

=

5231.90 (W

)

PROTECT

EX 6" GAS (NO LOCATE)

FIELD VERIFY

STA: 0+40.84

T.O.P.=5235.00

PROTECT

EX TEL (Qwest)

STA: 0+72.91

T.O.P.=5237.00

PROTECT

EX TEL (NO LOCATE)

FIELD VERIFY

STA: 0+76.88

T.O.P.=5235.15

EXISTING GROUNDAT CL OF PIPE

5 YEAR HGL

Q(5)=0.8 CFS

Q(FULL)=33 CFS

Q(5)=2.2 CFS

Q(FULL)=24.58 CFS

PROTECT

12" PVC WAT

5220

5225

5230

5235

5240

5245

5250

5255

5220

5225

5230

5235

5240

5245

5250

5255

0+00 0+80

SIN

GL

E T

YP

E 1

6 IN

LE

T-B

9.1

ST

A: 0

+1

7.7

6

RIM

=

5

24

0.8

1

18

" IN

V. O

UT

=

5

23

3.1

4 (E

)

24.74 LF

@ 5.17%

18" RCP

ST

M M

H-B

9 (M

H T

EE

)

ST

A: 3

2+

72

.8

3

RIM

=

5

24

1.5

9

84

" IN

V. IN

=

5

22

5.7

6 (S

)

84

" IN

V. O

UT

=

5

22

5.7

6 (N

)

18

" IN

V. IN

=

5

23

1.8

6 (W

)

18

" IN

V. IN

=

5

23

1.8

6 (E

)

19.69 LF

@ 3.02%

18" RCP

SINGLE TYPE 16 INLET B9.2

STA: 0+62.19

RIM = 5241.24

18" INV. OUT = 5232.45 (W)

EX 12" WAT

(ASSUMED ELEV)

STA: 0+47.46

T.O.P.=5236.68

493.0 LF

@ 0.30%

24" PVC SAN

PROTECT

EX FO (AT&T) NO LOCATE

FIELD VERIFY

STA: 0+19.88

T.O.P.=5236.90

PROTECT

EX 6" GAS (NO LOCATE)

FIELD VERIFY

STA: 0+30.46

T.O.P.=5237.66

PROTECT

EX TEL (NO LOCATE)

FIELD VERIFY

STA: 0+59.47

T.O.P.=5237.30

PROTECT

EX TELE (NO LOCATE)

FIELD VERIFY

STA: 0+60.69

T.O.P.=5237.28

EXISTING GROUNDAT CL OF PIPE

5 YEAR HGL

Q(5)=0.5 CFS

Q(FULL)=24 CFS

Q(5)=2.8 CFS

Q(FULL)=18 CFS

PROTECT

12" PVC WAT

EX 6

" GAS

STA

: 0

+5

6.2

5T.

O.P

.=5

23

8.5

3'

PR

OT

EC

T

G A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

NG

A

BA

N

SA

N

S

A

N

S

A

N

S

A

N

S

A

N

SA

NS

AN

SA

NS

AN

SAN

SA

N

F

O

A

B

A

N

F

O

A

B

A

N

EX

C

AB

LE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

W

W

W

W

W

XX

XX

XX

XX

XX

XX

XX

X

X

X

X

W A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

NW

A

BA

N

FO

FO

FO

FO

FO

FO

FO

W

W

WW

WW

W

W

FO

FO

FO

FO

F

O

F

O

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

WW

W

S

A

N

S

A

N

FO

FO

FO

FO

FO

FO

G

G

G

G

G

G

G

GG

G

37

+0

0

38

+0

0

39

+0

0

40

+0

0

SA

N

EX 18" PVC SAN

EX 18" PVC SAN

N D

AH

LIA

ST

RE

ET

STAPLETON DR. S.

INTERSTATE-70(ELEVATED)

E

X

A

B

A

N

D

O

N

E

D

S

A

N

I

T

A

R

Y

STM MH-B11 (TYPE B)

STA 39+39.30, 0.00'

N=3397.6691

E=7494.6605

500.09 LF

EX TAP

(TYP)

37.59'

23.62'

29.13'

END PIPE JACKING

STA=38+13.44

OFF=4.81

N=3523.59

E=7491.76

12" PVC

0+00 0+91.88

STORM-5

422.84 LF

84" RCP

206.37 LF

24" PVC

331.77 LF

21" PVC

22.00 LF

18" RCP

29.88 LF

18" RCP

12' TYPE 14 INLET-B-11.2

STA 0+71.88, 0.00'

N=3397.6997

E=7516.6632

6' TYPE 14 INLET-B-11.1

STA 0+20, 0.00'

N=3397.6276

E=7464.7849

EX 18" PVC SANEX 18" PVC SAN

PROTECT

EX F.O. (AT&T)

PROTECT

EX F.O. (QWEST)

PROTECT EX GAS

5225

5230

5235

5240

5245

5250

5255

5260

5225

5230

5235

5240

5245

5250

5255

5260

0+00 0+92

6' T

YP

E 1

4 IN

LE

T-B

-1

1.1

ST

A: 0

+2

0

RIM

=

5

24

6.9

2

18

" IN

V. O

UT

=

5

23

8.9

6 (E

)

PROTECT

EX 6" GAS (NO LOCATE)

FIELD VERIFY

STA: 0+23.94

T.O.P.=5242.87

ST

M M

H-B

11

(T

YP

E B

)

ST

A: 3

9+

39

.3

0

RIM

=

5

24

7.4

8

84

" IN

V. IN

=

5

22

8.1

6 (S

)

84

" IN

V. O

UT

=

5

22

7.9

6 (N

)

18

" IN

V. IN

=

5

23

7.4

7 (E

)

18

" IN

V. IN

=

5

23

7.4

7 (W

)

12

' T

YP

E 1

4 IN

LE

T-B

-1

1.2

ST

A: 0

+7

1.8

8

RIM

=

5

24

7.0

1

18

" IN

V. O

UT

=

5

23

8.5

7 (W

)

29.88 LF

@ 5.00%

18" RCP

PROTECT

EX ATT FO (NO LOCATE)

FIELD VERIFY

STA: 0+30.40

T.O.P.=5243.07

PROTECT

FO (QWEST) NO LOCATE

FIELD VERIFY

STA: 0+62.10

T.O.P.=5244.19

PROTECT

FO (QWEST) NO LOCATE

FIELD VERIFY

STA: 0+66.91

T.O.P.=5244.08

EX 12" WAT FIELD VERIFY

(ASSUMED T.O.P.)

STA: 0+56.37

T.O.P.=5242.83

(ABANDONED)

EXISTING GROUNDAT CL OF PIPE

22.00 LF

@ 5.00%

18" RCP

5 YEAR HGL

Q(5)=1.7 CFS

Q(FULL)=23 CFS

Q(5)=6.9 CFS

Q(FULL)=23 CFS

206.60 LF

@ 0.41%

EX 18 SAN"

13 OF 17

MAY 2016

D-04-323-STM-02.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

ST

OR

M LA

TE

RA

LS

P

LA

N A

ND

P

RO

FILE

N

STORM-5 PLAN AND PROFILE

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

NOTES:

1. THE CITY OF DENVER ASSUMES NO RESPONSIBILITY FOR

EXISTING UTILITY LOCATIONS. THE UTILITIES SHOWN ON

THIS DRAWING HAVE BEEN PLOTTED FROM THE BEST

AVAILABLE INFORMATION. IT IS, HOWEVER, THE

CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY THE

LOCATION OF ALL UTILITIES PRIOR TO THE

COMMENCEMENT OF ANY CONSTRUCTION.

2. STORM SEWER PIPE LENGTHS ARE TWO DIMENSIONAL

LENGTHS. LENGTHS ARE CENTER TO CENTER BETWEEN

MANHOLES AND TO INSIDE OF BOX FOR INLETS.

3. STORM SEWER LENGTHS WITH FLARED END SECTIONS

ARE TO END OF FLARED END SECTION.

4. STORM SEWER MAIN SHALL BE ASTM C-76 CLASS III PIPE

UNLESS OTHERWISE NOTED.

STORM-3 PLAN AND PROFILE STORM-4 PLAN AND PROFILE

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

AutoCAD SHX Text
T
AutoCAD SHX Text
230'
AutoCAD SHX Text
T
AutoCAD SHX Text
170'
AutoCAD SHX Text
T
AutoCAD SHX Text
227'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
TC
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
WV
AutoCAD SHX Text
E
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
208'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
T
AutoCAD SHX Text
23'
AutoCAD SHX Text
T
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
1"= ' VERT.
AutoCAD SHX Text
20
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
40
AutoCAD SHX Text
4
AutoCAD SHX Text
STORM-5
AutoCAD SHX Text
STORM-3
AutoCAD SHX Text
STORM-4
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 12: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

ST

MS

TM

T

T

T

T

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

G

G

G

TT

GG

T

G

G ABAN G ABANG ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN

SA

N

SA

N

S

A

N

SA

N

SA

N

S

A

N

S

A

N

S

A

N

S

A

N

S

A

N

S

A

N

SANSAN

SAN SAN SANSAN

SAN SAN SAN SAN SAN

SA

N

SA

N

SA

N

ST

M

G A

BA

N

FIBER OPTIC CABINET

F

O

A

B

A

N

G

G A

BA

N

G ABAN

G A

BA

N

G

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX

O

HE

EX OHEEX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHEEX OHE

EX OHEEX OHE

EX OHE

EX OHEEX OHE

EX OHE

EX OHE

EX

O

HE

EX

O

HE

E

X

O

H

EE

X

O

H

E

EX OHEEX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHEEX OHE

EX OHE

EX

O

HE

EX

O

HE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

W

W

W

W

W

W

W

W

W

W

W

X X X

X

X

X

X X X X X

XXXXXXXXX

X

X

W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN

W ABAN W ABANW ABAN W ABAN W ABAN

W ABANW ABAN

W ABANW ABAN

W ABANW ABAN

W ABANW ABAN

W ABAN

W ABAN

W ABAN

F

O

M

M

M

M

T

T

T

M

M

T

FO

G

G

W W

FO

FO

FO

FO

FO FO

FO

FO

G

W

W

W

FO

FO

FOFO FO FO

FOFO

FO

FO

FO

FO

FO

FO

FOF

O

FO

FO

FO

FO

FO FO

FO

W

WW

WW

WW

FO

FO

FO

FO

FO

FO

F

O

FO

FOFO

FO

FO

FO

FOFO

FO

FO

F

O

FO FO FO

FO

FO

FOFO

FO

FO FO

FO

FO

FO

W

W

WW

WW W W W

W

WW

W

W

W

W

WW

WW

S

A

N

FOFO

FO

FO

FO

FO

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABANG ABAN

G ABAN G ABANG ABAN

G ABANG ABAN

G ABAN

G ABAN

G ABAN

G

G

G

G

G G GG

G

G

G

GG

G

G

GG

G

G

G

G

G

G

G

G G

G G

KB-2

KB-3

KB-1

KB-4

KB-5

N DAHLIA STREET

STA

PLET

ON

DR

. S.

STA

PLET

ON

DR

. N.

INTE

RST

ATE

-70

(ELE

VA

TED

)

NO PAVING

UNDER I-70

BN

SF

65.53'

70.53'

80'

80'

80'

80'

48T

H A

VE

NU

EP

HA

SE

IV

-A

PH

AS

E V

BA

SE

B

ID

AD

D A

LT

. 1

AD

D A

LT

. 2

BA

SE

B

ID

AD

D A

LT

. 1

STM STM STM

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABAN G ABANG ABAN

G ABAN

G ABANG ABAN G ABAN G ABAN G ABAN G ABAN G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

SAN SAN SAN

S

A

N

S

A

N

S

A

N

SANSAN

SAN SAN SAN SANSAN

SA

N

SAN SAN SAN SAN SAN SAN SAN SAN

SA

N

SANSAN

SAN SAN SAN

S

A

N

F

O

A

B

A

N

T

T

T

T

T

T

T

T

F

O

A

B

A

N

W

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHEEX OHE

EX OHEEX OHE EX OHE

EX OHEEX OHE

EX OHEEX OHE EX OHE EX OHE EX OHE EX OHE EX OHE EX OHE EX OHE EX OHE

EX OHE

EX OHE

E

X

O

H

E

E

X

O

H

E

EX

O

HE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

EX OHE

S

A

N

S

T

M

S

T

M

S

A

N

FO

AB

AN

FO ABANFO ABAN

FO

AB

AN

W

W

A

B

A

N

W

A

B

A

N

W

A

B

A

N

W A

BA

N

W

W

W

W

W

W

W

X

X

X

X X X X X X X X X X X X X X

X X X X X X X X X

X

X

X

X X X X X

XXXXXXXXXXXXXX

X

X

W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABANW ABAN W ABAN W ABAN W ABAN W ABAN W ABAN

W ABAN W ABAN

W ABAN

T

FO

FO

FO

FO FO

FOFO

FOFO

FO FO

F

O

FO FO

FOFO FO

FO

FOW

WW

WW

WW

W

WW W

W

FO

FO

FO

FO

FO

FO

FO

FOFO

FO

FOFO FO FO

FO

FO FO

FO

F

O

FO

FO

FO

FO

W

E

E

E

E

E

G

G

G

G

G

FO

FO

FO

F

O

F

O

FO

FO

FO FO

WW

W

W

W

W WW

F

O

F

O

E

G

G

FO

F

O

F

O

FO

FO

W

E

E

E

E

FO

FO

FO

FO

FO

FO

FO

FO

W

S

A

N

FO

FO

W W W W W

FO

FO

FO

FO

G

G

G

G

G

G G

G G GG G G G G

G G GG G G

G

G

G

G

KB-5

KB-6

KB-7

KB-8

E

T

U

U

U

U

T

T

U

UU

U

X=660620.7520Y=454694.3368

X=660629.1543Y=454744.6359

X=660641.7492Y=454739.4040

X=660597.7297Y=454556.4515

X=660590.0017Y=454510.1187X=660590.0017Y=454510.1187X=660590.0017Y=454510.1187X=660590.0017Y=454510.1187

X=660637.0491Y=454500.1364

X=660638.6004Y=454361.4646

X=660711.8268Y=454361.4439

X=660724.8176Y=454740.5581

X=660573.1129Y=454560.8118

X=660565.5239Y=454515.3123

X=660468.7147Y=454558.5754X=660468.7141Y=454558.5755X=660468.7068Y=454558.5788

W

W

N DAHLIA STREET

SMIT

H R

OA

D

STA

PLET

ON

DR

. S.

UPR

R

END PAVING

AT ROW

65.53'

70.53'

RTD

EA

STLI

NE

AD

D A

LT

. 1

AD

D A

LT

. 2

AD

D A

LT

. 2

PH

AS

E V

B

14 OF 17

MAY 2016

D-04-323-PAV-PH.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

PA

VIN

G P

LA

N

PAVING PLAN NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

N

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

CONCRETE PAVING AT

SMITH AND DAHLIA

INTERSECTION.

1,355 SY

EXISTING A.C. TO BE

REMOVED AND REPLACED

DAHLIA STREET

11,000 SY

NOTE:

DAHLIA STREET WILL BE REPAVED

FROM LIP OF GUTTER TO LIP OF

GUTTER AS SHOWN.

MIN

PAVEMENT SECT

3'℄

80'

2'3' 2'

VARIES

44.76' MIN

PAVEMENT SECT

5'

SIDEWALK

C&G

65.53' AND 70.53'

C&G

5'

SIDEWALK

44'

BOTTOM 9" S100

PG 64-22

25% RAP

TOP 2.5"

S100 PG 64-22

20% RAP

BOTTOM 9" S100

PG 64-22

25% RAP

TOP 2".5

S100 PG 64-22

20% RAP

5' PAN

SEE THIS SHEET

FOR DETAIL

5' PAN

SEE THIS SHEET

FOR DETAIL

2%

2%

EA

ST

RO

W

WE

ST

RO

W

EA

ST

RO

W

WE

ST

RO

W

DAHLIA STREET (SOUTH OF I-70) CROSS SECTIONDAHLIA STREET (NORTH OF I-70) CROSS SECTION

AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
80'
AutoCAD SHX Text
T
AutoCAD SHX Text
121'
AutoCAD SHX Text
T
AutoCAD SHX Text
230'
AutoCAD SHX Text
T
AutoCAD SHX Text
125'
AutoCAD SHX Text
T
AutoCAD SHX Text
170'
AutoCAD SHX Text
T
AutoCAD SHX Text
227'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
T
AutoCAD SHX Text
208'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
T
AutoCAD SHX Text
23'
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
E
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
GV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
T
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
REMOVE AND REPLACE EXISTING CURB RETURN AND RAMP WITH A SINGLE CURB RAMP TYPE 2 PER CCD STANDARD
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
222'
AutoCAD SHX Text
T
AutoCAD SHX Text
208'
AutoCAD SHX Text
T
AutoCAD SHX Text
MH
AutoCAD SHX Text
T
AutoCAD SHX Text
23'
AutoCAD SHX Text
T
AutoCAD SHX Text
310'
AutoCAD SHX Text
TC
AutoCAD SHX Text
T
AutoCAD SHX Text
TH#7
AutoCAD SHX Text
TH#8
AutoCAD SHX Text
T
AutoCAD SHX Text
236'
AutoCAD SHX Text
WV
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
E
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
E
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX 18" UNK
AutoCAD SHX Text
EX 18" UNK
AutoCAD SHX Text
EX 18" UNK
AutoCAD SHX Text
EX AT&T FO
AutoCAD SHX Text
EX AT&T FO
AutoCAD SHX Text
EX AT&T FO
AutoCAD SHX Text
EX CC FO
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX CC FO
AutoCAD SHX Text
EX CL FO
AutoCAD SHX Text
EX 6" STL
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX XGS
AutoCAD SHX Text
EX WS
AutoCAD SHX Text
EX WS
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX 6" STL
AutoCAD SHX Text
EX 6" STL
AutoCAD SHX Text
EX 6" STL
AutoCAD SHX Text
EX WS
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX 18" UNK
AutoCAD SHX Text
EX 6" STL
AutoCAD SHX Text
EX 12" STL
AutoCAD SHX Text
EX 21" PVC
AutoCAD SHX Text
EX CL FO
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX MCI FO
AutoCAD SHX Text
EX CL FO
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX 3" STL
AutoCAD SHX Text
EX AT&T FO
AutoCAD SHX Text
EX CC FO
AutoCAD SHX Text
EX SD
AutoCAD SHX Text
EX 18" UNK
AutoCAD SHX Text
EX WS
AutoCAD SHX Text
EX WS
AutoCAD SHX Text
EX XGS
AutoCAD SHX Text
EX TRAFFIC FO
AutoCAD SHX Text
T
AutoCAD SHX Text
8
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
12
AutoCAD SHX Text
QL "C" 36" RCP STORM
AutoCAD SHX Text
9
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
8
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
8
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
8
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
8
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
7
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
11
AutoCAD SHX Text
QL "C" 18" RCP
AutoCAD SHX Text
13
AutoCAD SHX Text
QL "C" 10" RCP
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
25
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
50
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 13: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

G

A

B

A

N

WW

WW

G A

BA

N

G A

BA

N

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABANG ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABAN

G ABANG ABAN

G ABAN

SAN SAN SAN SAN SAN

SA

N

SA

N

SA

N

SA

N

SANSAN

SANSAN

SANSAN

SANSAN

SANSAN

SANSAN

SANSAN

T

T

T

T

T

T

T

T

T

T

T

FO

F

O

A

B

A

N

F

O

A

B

A

N

F

O

A

B

A

N

F

O

A

B

A

N

F

O

A

B

A

N

F

O

A

B

A

N

F

O

A

B

A

N

F

O

A

B

A

N

FO

A

BA

N

F

O

A

B

A

N

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

EX

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

EX

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

E

X

O

H

E

EX

OH

E

W

A

B

A

N

W

A

B

A

N

WW

W

WW

W

W

X

X

X

X X X X X X X X X X X

W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABANW ABAN W ABAN

W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABAN W ABANW ABAN W ABAN W ABAN W ABAN

W

A

B

A

N

W

A

B

A

N

W ABAN

W ABAN

W

W

FO

FO

FO

FO

FO

FO

FO

FO

FO

W

W

W

W

WW

W

W

W

W

FOFO

FOFO

FO

FO

E

E

E

E

EE E

E

E

E

E

E

W

W

FO

FO

FO

FO

FO FO

FO

FO

F

O

FO

FO

FO

FO

FO

F

O

F

O

F

O

F

O

F

O

F

O

F

O

F

O

WW W

W WW

WW

W WW

W

W

W

W

W

WW

FO

FO

E

E

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO FO

FO

FO

GG

GG

G

G

G

G

G

G

G

G

G

G

G

G

G

KB-7

N=2,388.26

E=7,495.49

N=2,387.88

E=7,489.48

N=2,391.01

E=7,492.41

N=2,363.96

E=7,494.72

N=2,324.32

E=7,486.95

N=2,407.05

E=7,508.53

N=2,407.78

E=7,468.65

N=2,377.94

E=7,490.25

N=2,324.00

E=7,492.94

REMOVE EXISTING MEDIAN AS DIRECTED

BY CONSTRUCTION ENGINEER AND

REPLACE WITH PATTERNED CONCRETE

MEDIAN. SEE NORTH MEDIAN DETAIL ON

SHEET 16

REMOVE EXISTING PAVEMENT AS DIRECTED BY

CONSTRUCTION ENGINEER AND REPLACE WITH

CONCRETE PAVEMENT PER CCD STANDARDS.

CONTRACTOR TO PROVIDE CONCRETE GRID LINE

PLANS FOR APPROVAL PRIOR TO INSTALLATION OF

CONCRETE PAVEMENT. SEE SECTION DETAIL ON

SHEET 16

N=2,323.35

E=7,505.43

N=2,325.42

E=7,465.96

BEGIN JACKING/BORE 84" RCP

N=2,380.75

E=7,479.15

BEGIN JACKING/BORE 21" SAN

N=2,388.16

E=7,492.48

T

T

STM STM STM STMSTM STM STM STM STM STM STM STM STM STM STM STM STM STM STM STM

SA

N

SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN SAN

SAN

SAN

S

A

N

S

A

N

SANSAN SAN SAN SAN SAN SAN SAN SAN SAN

SAN SAN SAN SAN SAN SAN SAN SAN SANSAN

T

T

T

T

T

T

T

T

T

T

T

T

T

T

T

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

EX OHE

S

A

N

S

A

N

S

A

N

S

A

N

S

A

N

S

A

N

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

S

T

M

FO

AB

AN

FO

AB

AN

FO

AB

AN

FO

AB

AN

FO

AB

AN FO ABAN

FO ABAN FO ABAN FO ABANFO ABAN

FO ABAN FO ABANFO ABAN

FO ABAN

FO ABAN

FO ABAN

FO ABAN

FO ABAN

FO ABAN

FO ABAN

FO ABAN

FO

AB

AN

FO

AB

AN

FO A

BA

N

FO

AB

AN

FO ABANFO ABAN

FO ABAN

G GG

W ABAN

W ABAN

E

E

E

E

E

E

E

E

E

EE

E

E

E

E

E

E

EE E

E

E

E

EE

E

E

G

G

G

G

G

G

G

G

G

G

G

F

O

F

O

F

O

F

O

F

O

FOFO

FO

FO

FO

FO

FO

FO

FO

FO

FO FO FO FO

FO

FO FO FO

FO

FO

FO

FO

W

W

W

W

W

W

W

W

W W

W

WW W W W W W W W W W W

W

W

W

W

W

W

W

W

F

O

F

O

F

O

F

O

F

O

F

O

F

O

FO

G

G

G

G

G

G

G

G

G

G G G

G

G

G

G

G

W

W

W

FOFO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO

FO FOFO FO

FO

FO

FO

FO

FO

FO

FO

FOFO FO

FOFO

FO FO

FO

FO

FO

G G GG G G G

KB-8

SMIT

H R

OA

D

N=2,069.36

E=7,467.67

N=2,068.99

E=7,462.69

N=2,071.67

E=7,465.00

N=2,020.35

E=7,471.27

N=2,019.98

E=7,466.28

N=2,005.73

E=7,471.82

N=2,005.72

E=7,466.82

N=1,979.60

E=7,471.88

N=1,979.59

E=7,466.88

N=1,977.10

E=7,469.38

REMOVE EXISTING MEDIAN AND

REPLACE WITH PATTERNED CONCRETE

MEDIAN. SEE DETAIL ON SHEET 16

N=2,013.05

E=7,471.67

N=2,012.86

E=7,466.68

REMOVE EXISTING PAVEMENT PER CCD CONSTRUCTION ENGINEER AND

REPLACE WITH CONCRETE PAVEMENT PER CCD STANDARDS.

CONTRACTOR TO PROVIDE CONCRETE GRID LINE PLANS FOR APPROVAL

PRIOR TO INSTALLATION OF CONCRETE PAVEMENT. SEE SECTION DETAIL

ON SHEET 16

N=1,979.60

E=7,469.38

N=2,069.17

E=7,465.18

N=1,974.16

E=7,494.90

N=1,974.06

E=7,451.04

SOUTH B

SOUTH B

SOUTH A

SOUTH A

15 OF 17

MAY 2016

D-04-323-MEDIAN.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

ME

DIA

N P

LA

N

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

N

KEY MAP

N.T.S.

E 48TH AVE

I-70

N C

OL

OR

AD

O B

LV

D

N

PHASE IV-A

PHASE V

BA

SE

B

ID

AD

D A

LT

1

N D

AH

LIA

S

T

PHASE IV-A

PHASE V

AD

D A

LT

2

SM

ITH

RD

CONSTRUCTION COMPLETED

NOTE: THE MEDIAN IMPROVEMENTS ARE INCORPORATED

FROM THE RTD FASTRACK IMPROVEMENTS.

CONTRACTOR SHOULD REFERENCE THOSE PLANS FOR

DESIGN DETAILS.

DAHLIA STREET MEDIAN PLAN-NORTH OF SMITH ROAD

DAHLIA STREET MEDIAN PLAN-SOUTH OF SMITH ROAD

NORTH OF SMITH RD

SOUTH OF SMITH RD

S

M

IT

H

R

D

AutoCAD SHX Text
TC
AutoCAD SHX Text
TC
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
EX 18" UNK
AutoCAD SHX Text
EX AT&T FO
AutoCAD SHX Text
EX CL FO
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX MCI FO
AutoCAD SHX Text
QL "C" 36" RCP STORM
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
8
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
M
AutoCAD SHX Text
GV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
D
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
M
AutoCAD SHX Text
EX 12" PVC
AutoCAD SHX Text
EX 3" STL
AutoCAD SHX Text
EX AT&T FO
AutoCAD SHX Text
EX CC FO
AutoCAD SHX Text
EX SD
AutoCAD SHX Text
EX 18" UNK
AutoCAD SHX Text
8
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
3
AutoCAD SHX Text
QL "C"
AutoCAD SHX Text
M
AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
ORIGINAL SCALE: 1"= ' HORIZ.
AutoCAD SHX Text
0
AutoCAD SHX Text
5
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
10
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
Page 14: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

16 OF 17

MAY 2016

D-04-323-MEDIAN.dwg

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

ME

DIA

N D

ET

AIL

NO.

DESC

RIPT

ION

OF R

EVIS

IONS

DATE

BY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

11.0'

LANELANE

DAHLIA ST

L

C

SDWK LANE

DAHLIA ST

L

C

11.0'14.5'

10.5'

PGL

EXISTING

PAVEMENT

2%

SAW CUT

2%

SDWK

2%

11.0'

LT TURN

LANE

LANE

TYPICAL SECTION-MEDIAN SOUTH B

SDWK

2%

2%

EXISTING

R/W

EXISTING

R/W

EXISTING

R/W

PROPOSED

R/W

TYPICAL SECTION NOTES

GROOVE DIMENSIONS

WIDTH = APPROX 1/4"

DEPTH = APPROX 1/2"

BACK OF CURB

3

'-

0

"

T

Y

P

3

'

-

0

"

T

Y

P

65.00'

EXISTING

R/W

37.0'37.0'

8.0'1.5'

2.5

'

8.0' 1.5'

37.0'

37.0'

VARIES 37.0' TO 66.0'

8.0'

2.5'

2.5'

1'-0"

1'-6"

1

1

2

"4

1

2

"

9"

1

1

2" R

1

8" R

9" VERTICAL CURB & 1' SPILL PAN DETAIL

9" VERTICAL CURB & 1' SPILL PAN DETAIL NOTES:

SE

E

NO

TE

1

1"

6" CURB AND GUTTER - 2' PAN

PER CCD STD DWG 5.3a

6" CURB AND GUTTER - 2' PAN

PER CCD STD DWG 5.3a

6" CURB AND GUTTER - 2' PAN

PER CCD STD DWG 5.3a

15

" (S

EE

N

OT

E 1

)

5.5'

4.0'

VARIES

5.5' TO 9.5'

1. IF CONSTRUCTED ADJACENT TO HMA PAVEMENT, PAN THICKNESS IS

6" MINIMUM . IF CONSTRUCTED ADJACENT TO PCC PAVEMENT, PAN

THICKNESS TO MATCH THICKNESS OF ADJACENT PCC PAVEMENT.

VARIES

11.0' TO 15.0'

LT TURN

LANE,

STRIPED

MEDIAN

6" CURB AND GUTTER-1' SPILL PAN

PER CCD STD DWG 5.3a (TYP)

1.5'

(TYP)

1.5'

(TYP)

4.0'

CURB HEAD-FILL SECTION

POSS

POSS

POSS

PLACE 4 INCHES OF TOPSOIL TO THIS LINE AFTER COMPLETION

OF PAVING OPERATIONS. IF EXISTING MATERIAL IS OTHER THAN SOIL,

REPLACE IN KIND.

CONSTRUCT AT 2.0% CROSS SLOPE IN FULL RECONSTRUCTION AREAS.

MATCH EXISTING CROSS SLOPE IN PAVEMENT WIDENING AREAS

EXCEPT AS SHOWN IN THE CROSS SECTIONS.

VERTICAL ALIGNMENT CONTROL POINTS.

POINT OF SLOPE SELECTION

PROVIDE CURB AND GUTTER TRANSITION FROM STANDARD TO MATCH

EXISTING GROUND OVER A DISTANCE OF 6'-0". THIS APPLIES WHERE

CURB AND GUTTER ENDS AT ALL TRACK CROSSING.

FOR VARYING DIMENSIONS SEE PLAN AND PROFILE SHEETS FOR

ADDITIONAL DETAIL.

SEE PAVING AND GRADING PLANS FOR PAVEMENT CROSS-SLOPE

TRANSITIONS.

TYPICAL SECTIONS ARE NOT INTENDED FOR STAKING THE PROJECT.

SEE ROADWAY PLANS FOR GENERAL LAYOUT AND STATION/OFFSET

INFORMATION.

SEE CROSS SECTIONS FOR FORE SLOPES AND BACK SLOPES.

SEE EAST SMITH ROAD TYPICAL SECTIONS FOR THICKNESS OF

CONCRETE PAVEMENT THROUGH INTERSECTION OF

EAST SMITH ROAD AND DAHLIA STREET.

PGL

TYPICAL SECTION-MEDIAN SOUTH A

6" CURB AND GUTTER-1' SPILL PAN

PER CCD STD DWG 5.3a (TYP)

10" HMA

10" HMA

12" ABC (CL 6)

12" ABC (CL 6)

MEDIAN COVER MATERIAL

(PATTERNED CONCRETE)

MEDIAN COVER MATERIAL

(PATTERNED CONCRETE)

MEDIAN COVER MATERIAL (PATTERNED CONCRETE) DETAIL

MEDIAN COVER MATERIAL (PATTERNED CONCRETE) NOTES:

4" O

R 8

"

1.

1

2" EXPANSION JOINT SHALL BE PLACED BETWEEN THE CURB

AND MEDIAN COVER MATERIAL.

2. MEDIAN COVER MATERIAL SHALL BE ALTERNATING BRUSHED PATTERN

AS SHOWN ABOVE.

3. CONTROL JOINTS FOR MEDIAN COVER MATERIAL SHALL BE PLACED

EVERY 10' WITH A MINIMUM DEPTH OF 1".

4. PROVIDE OPENINGS FOR SIGN POSTS AND SIGNALIZATION FOUNDATIONS.

5. MEDIAN COVER MATERIAL THICKNESS SHALL BE 8" THICK BETWEEN CRT

AND UPRR, WHERE ACCESS BEING PROVIDED. ALL OTHERS AREAS MEDIAN

COVER MATERIAL SHALL BE 4" THICK.

6. SIDEWALK ADJUST TO 8" THICK MEDIAN COVER MATERIAL SHALL BE

8" THICK PCCP.

SEE NOTE 5

1.5'1.5'

11'11'

Lane Lane

2.5'2.5'

Dahlia St

Varies

L

C

PGL

18'

Lt. Turn

Lane

Median Cover Material

Patterned Concrete

4" Thick

6" Curb and Gutter - 2' Pan

per CCD STD DWG 5.3a

Sta 16+23.56 to 16+60.97

Sta 16+94.35 to 18+66.15

6" Curb and Gutter - 1' Pan

per CCD STD DWG 5.3a

6" Curb and Gutter - 2' Pan

per CCD STD DWG 5.3a

Sta 16+29.21 to 16+65.41

Sta 16+99.74 to 21+36.93

6" Curb and Gutter - 1' Pan

per CCD STD DWG 5.3a

11" Concrete

Pavement

11" Concrete

Pavement

6

:1

6:1

P.O.S.S.

6:1

6

:1

P.O.S.S.

2%

2%

1.5' 1.5'

8.5'

Concrete

(Scored)

5' Min.

Side-

walk

8.5'

Concrete

(Scored)

5' Min.

Side-

walk

Raised

Median

5'

CONCRETE PAVEMENT NOTES

1. CONSTRUCT THICKENED CONCRETE PAVEMENT SECTION AT BUTT

JOINTS TO EXISTING OR PROPOSED ASPHALT PAVEMENT PER

CCD STD DWG 11.4 .

2. CONTRACTOR TO PREPARE AND SUBMIT FOR APPROVAL CONCRETE

JOINTING PLANS. ALL TRANSVERSE JOINTS REQUIRE LOAD TRANSFER

DOWEL BARS. SEE CDOT STD PLAN NO. M-412-1.

3. ALL CONCRETE FOR CONCRETE PAVEMENT SHALL BE CDOT CLASS P

WITH AIR CONTENT 5.0% MINIMUM TO 8.0% MAXIMUM. THE MIX

CAN HAVE 3/4" AGGREGATE SIZE (#67 OR #57) OR 1.5" (#467

OR #357).

4. CONTRACTOR HAS THE OPTION TO USE CDOT CLASS E CONCRETE

TO OPEN PAVEMENT TO SERVICE SOON AFTER PLACEMENT. NO

ADDITIONAL PAYMENT FOR USE OF CLASS E CONCRETE.

5. CONTRACTOR HAS THE OPTION TO CONSTRUCT CURB, GUTTER AND

PAVEMENT MONOLITHIC PER CDOT STD PLAN NO. M-412-1.

6. THE CCD MAXIMUM MONOLITHIC PLACEMENT IS 14.0' FROM THE

LONG JOINT TO THE BACK OF CURB; OTHERWISE, USE LONG JOINT OR

TIED LONGITUDINAL (L) JOINT ON GUTTER PAN EDGE.

7. CONSTRUCT CURB AND GUTTER THE SAME THICKNESS AS ADJACENT

PAVEMENT.

8. DOWEL NEW CONCRETE PAVEMENT INTO EXISTING PAVEMENT PER

CCD STD DWG. 11.2B AND DWG. 11.4.

9. CONSTRUCT TEMPORARY ASPHALT PAVEMENT BETWEEN THE UPRR

TRACKS. ONCE THE TRACKS HAVE BEEN UTILIZED AND THE PANELS

HAVE SETTLED, PERMANENT CONCRETE WILL BE PLACED.

10. TRANSITION CONCRETE PAVEMENT TO ASPHALT PAVEMENT AS PER

CCD DWG 11.4.

11. INSTALL 3" INTERCONNECT CONDUIT BETWEEN SMITH RD AND THE

CONSTRUCTION LIMIT. LOCATION PER CCD DWG 16.7 OR AS

DIRECTED IN THE FIELD BY INSPECTOR. INSTALL TRAFFIC PULL BOXES AT

EACH INTERSECTION AND 350' MAXIMUM LENGTH OF CONDUIT.

TYPICAL SECTION NOTES

CROSS-SLOPE, 2% IN FULL RECONSTRUCTION AREAS OR MATCH EXISTING,

EXCEPT AS SHOWN ON PAVING AND GRADING PLANS.

PROVIDE CURB AND GUTTER TRANSITION IN ACCORDANCE WITH SHEET

CSD-003. THIS APPLIES WHERE CURB AND GUTTER ENDS AT ALL

TRACK CROSSING.

FOR VARYING DIMENSIONS SEE PLAN AND PROFILE SHEETS FOR

ADDITIONAL DETAIL.

SEE PAVING AND GRADING PLANS FOR PAVEMENT CROSS-SLOPE

TRANSITIONS.

TYPICAL SECTIONS ARE NOT INTENDED FOR STAKING THE PROJECT.

SEE ROADWAY PLANS FOR GENERAL LAYOUT AND STATION/OFFSET

INFORMATION.

THE CONTRACTOR SHALL BE REQUIRED TO PERFORM SOIL PREPARATION

(SPECIAL) AND SEEDING/MULCHING TO ALL DISTURBED SURFACE. (IF

EXISTING MATERIAL IS OTHER THAN SOIL, REPLACE IN KIND.)

BREAK POINTS IN SLOPES SHALL BE ROUNDED DURING

CONSTRUCTION FOR A PLEASING APPEARANCE.

VERTICAL ALIGNMENT CONTROL POINTS.

POINT OF SLOPE SELECTION

DAHLIA ST MEDIAN TYPICAL SECTION

NORTH OF SMITH ROAD

AutoCAD SHX Text
MWG
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
8-23-13
AutoCAD SHX Text
PCO 100% SUBMITTAL
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
%%U
AutoCAD SHX Text
1
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
P.O.S.S.
Page 15: CITY AND COUNTY OF DENVER BY MWG DATE · PDF filed-o4-323-cs.dwg aks aks aks park hill storm, phase v-----cover sheet mwg ... rcbc - reinforced concrete box culvert rcp - reinforced

STEPS ON REQUEST

MANHOLE TANGENT LEFT MIRROR IMAGE WILL APPLY

MANHOLE SHOWN TANGENT RIGHT, FOR

AS REQUIRED

PIPE I.D.

AS REQ'D

PRECAST REINFORCED CONCRETE

CONCENTRIC MANHOLE TEE

NOTES:

1. PRODUCED TO MEET ASTM SPECIFICATIONS.

WALL THICKNESS

TEE RISER CAN BE

BELL OR SPIGOT

TO MATCH RISER

PLAN VIEW

VIEW LOOKING FROM SPIGOT TO BELL

17 OF 17

MAY 2016

D-04-323-DET.DWG

AKS

AKS

AKS

PARK

HIL

L ST

ORM

, PHA

SE V

----

----

DE

TA

ILS

MW

G8

-2

3-1

3P

CO

1

00

% S

UB

MIT

TA

L1NO

.DE

SCRI

PTIO

N OF

REV

ISIO

NSDA

TEBY

CIT

Y A

ND

CO

UN

TY O

F D

ENV

ERD

EPA

RTM

ENT

OF

PUB

LIC

WO

RK

SEN

GIN

EER

ING

DIV

ISIO

N C

API

TAL

PRO

JEC

T M

AN

AG

EMEN

T20

00 W

. 3R

D A

VE.

DEN

VER

, CO

802

23TE

L.: (

303)

446

-361

7 F

AX

: (30

3) 4

46-3

647

CALL

UNC

CTW

O W

ORKI

NG D

AYS

BEFO

RE Y

OU D

IG1-

800-

922-

1987

UTIL

ITY

NOTI

FICA

TION

CEN

TER

OFCO

LORA

DOD

E N

V E

RTH

E M

ILE

HIGH

CIT

Y

AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
DRAWING NAME:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DRAWN BY: