commercial absorption heat pump water heater...commercial absorption heat pump water heater 2016...

19
Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan [email protected] Oak Ridge National Laboratory h

Upload: others

Post on 31-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

Commercial Absorption Heat Pump Water Heater

2016 Building Technologies Office Peer Review

Patrick Geoghegan [email protected]

Oak Ridge National Laboratory

h

Page 2: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

2

Project Summary

Timeline:Start date: 10/1/13

Planned end date: 9/30/17

Key Milestones 1. Completed breadboard analysis; 9/4/2015

2. Completed alpha prototype; 11/18/15

3. Complete beta prototype fabrication and evaluation; 9/30/16

Budget:

Total Project $ to Date:

• DOE: $1,392K

• Cost Share: *

Total Project $:

• DOE: $2,200K

• Cost Share: *

Key Partners:

Project Outcome:

An 140,000 BTU/hr GAHP achieving a cycle

COP of 1.63 at the rated condition of 47 oF

ambient.

The target market is the hospital, hotel and

full service restaurant gas hot water heating

market.

Field test unit will be ready in FY17.

A.O. Smith

Stone Mountain Technologies, Inc.

* In-kind contribution from CRADA partner – exceeds DOE

funding level; exact total is confidential information

Page 3: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

3

Purpose and Objectives

Problem Statement:

As stated in the BTO’s MYPP– 2020 Energy use intensity for WH 25% lower than 2010

energy-efficient baseline – part of 1.8 quads energy savings– In 2014, natural gas provided 3 quads of the estimated 18

quads of commercial buildings energy use– AHPWH achieving 45% energy savings compared to ENERGY

STAR-certified gas storage water heater– 2020 Target Primary Energy Factor 1.2– 2020 Target Installed Cost $7.14 ($/First Hour Rating)

Page 4: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

4

Purpose and Objectives

Space Heating17%

Cooling7%

Ventilation6%

Water Heating16%

Lighting…

Cooking25%

Refrigeration16%

Other3%

Food Service

Target Market and Audience: The natural gas commercial water heating market.A special emphasis on retrofits with minimal total installed cost

Page 5: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

5

Space Heating

37%

Cooling8%

Ventilation8%

Water Heating

19%

Lighting16%

Cooking2%

Refrigeration1%

Computers2%

Other7%

Inpatient Healthcare

Purpose and Objectives

Refrigeration 2%

Cooking3%

Lighting

25%

Water Heatin g32%

Ventila tion3%

Cooling5%

Space Heatin g22%

LodgingComputers 1%

Other7%

Page 6: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

6

Purpose and Objectives

Impact of Project:An 140,000 BTU/h HPWH unit achieving a cycle COP

of 1.63 at 47 oF rated ambient conditions

Field test unit FY 17

Continue to publish

One product line on the market by 2020

Capture 2-5% of the natural gas commercial water heating market by 2030

Page 7: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

7

Introduction

• Mechanical compressor replaced by Thermal Compressor

• Ammonia-water absorption system

• Heat Pump Unit sits outside building

Page 8: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

8

Approach

Approach:

Thorough single-effect cycle modeling to predict target performance

System and Component analysis of the prototypes to identify areas of improvement

Dedicated fabrication team at SMTI

Key Issues: High pressure drop on hydronic side and underperforming rectifier component

Distinctive Characteristics: Strong and dynamic relationship between partners and subcontractor

Page 9: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

9

Progress and Accomplishments

Accomplishments:

Optimized single-effect cycle model to predict target performance

Breadboard testing complete

87% of performance target at design condition

3:1 modulation achieved

Alpha packaged prototype fabricated and tested

92% of performance target at design condition

3:1 modulation achieved

Page 10: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

10

Progress and Accomplishments

Cycle COP of 1.45 at design ambient/ return of 47/100°F

Operation over significant ambient (0 to 55°F) and hydronic return (90 to 125°F) temperature ranges

Page 11: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

11

Progress and Accomplishments

Alpha Prototype

Nominal Output : 140,000 btu/hr (41.0 kW)

Gas Input: 97,000 btu/hr (28.4 kW)

Max Supply: 160°F (71°C)

Size: 49” × 66” × 65” ( 1.24 m × 1.68 m × 1.65 m)

Weight: ~1000 pounds

As of now:

Ambient: 0 to 78°F (-17.8 to 25.6°C)

Hydronic Return: 80 to 125oF (26.7 to 51.7oC)

Hydronic Supply: 92 to 142oF (33.3 to 61.1oC)

Modulation: 3:1

Page 12: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

12

Progress and Accomplishments

Cycle COP of 1.51 at design ambient/return of 47/100°F

Alpha Unit COP improvement of 0.06 compared to breadboard System

3:1 modulation achieved

Environmental Chamber Characterization underway at ORNL

Page 13: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

13

Progress and Accomplishments

Market Impact:

Standard Efficiency

Water Heater

Storage Tank

Heat Pump

Inlet Water

SP 140°FSP 140°F

Hot Water

Return Water

Standard Efficiency

Water Heater

Primary High

Efficiency Tank

Inlet Water

SP 140°FSP 140°F

Hot Water

Return Water

EnergyPlussimulations reveal average daily gas consumption drops from 1638 ft3 to 1104 ft3 based on real water draw data from a full service restaurant located in San Ramon, CA.

Page 14: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

14

Progress and Accomplishments

Lessons, Issues & Opportunities:

Rectifier performance below design for Breadboard and Alpha unit Component design change to limit heat exchange with surroundings

Pressure loss management across components with 14 gpm hydronic flow

Page 15: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

15

Project Integration and Collaboration

Partners, Subcontractors, and Collaborators: • ORNL: Expertise in building equipment performance evaluation

and modeling

• AO Smith (OEM): Provides component design, fabrication, testing support, market research, and cost share to the project

• SMTI: Provides component and system design, fabrication, testing, testing support, and market research

Project Integration: • Both are in constant communication with ORNL via conference

calls, emails, and task reports

Communications: Commercial Water Heating Using Gas Absorption Heat Pumps , ACEEE Hot Water Forum, Portland OR, February 2016ASHRAE 2016 in St. Louis and Purdue Conference 2016

Page 16: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

16

Next Steps and Future Plans

Next Steps and Future Plans:

Continued Testing & Verification of Alpha unit by ORNL (March to April 2016) Steady-state testing

Fabrication & Testing of Beta prototype at SMTI (May 2016) Target incremental performance improvements Controls optimization Test under commercial water heating conditions

Testing of Beta unit by ORNL (June 2016) Steady-state testing

Page 17: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

17

REFERENCE SLIDES

Page 18: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

18

Project Budget

Project Budget: DOE Total $2200kCost to Date: $1392kAdditional Funding: None expected

Budget History

10/1/13 – FY 2015(past)

FY 2016(current)

FY 2017 – 9/30/17(planned)

DOE Cost-share DOE Cost-share DOE Cost-share$1260k * $540k * $400k *

* In-kind contribution from CRADA partner – exceeds DOE funding level; exact total is confidential information

*

*

Page 19: Commercial Absorption Heat Pump Water Heater...Commercial Absorption Heat Pump Water Heater 2016 Building Technologies Office Peer Review Patrick Geoghegan geogheganpj@ornl.gov Oak

19

Project Plan and Schedule

Project Schedule

Project Start: 10/1/13

Projected End: 9/30/17

Task

Q1

(Oct

-Dec

)

Q2

(Jan

-Mar

)

Q3

(Ap

r-Ju

n)

Q4

(Ju

l-Se

p)

Q1

(Oct

-Dec

)

Q2

(Jan

-Mar

)

Q3

(Ap

r-Ju

n)

Q4

(Ju

l-Se

p)

Q1

(Oct

-Dec

)

Q2

(Jan

-Mar

)

Q3

(Ap

r-Ju

n)

Q4

(Ju

l-Se

p)

Past Work

Q4 Go/No-Go: Complete BB prototype design

Q4 Milestone: Complete BB analysis

Q4 Milestone: complete alpha

Current/Future Work

Q3 Milestone: submit alpha testing report

Q4 Milestone: submit beta performance report

Completed Work

Active Task (in progress work)

Milestone/Deliverable (Originally Planned) use for missed

Milestone/Deliverable (Actual) use when met on time

FY2014 FY2015 FY2016