cooling capacities up to 11 kw - ams technologies · pdf file 89903_lytron_catalog_2011:lytron...

Click here to load reader

Post on 19-Oct-2020

1 views

Category:

Documents

0 download

Embed Size (px)

TRANSCRIPT

  • Recirculating ChillersKodiak® St

    an da

    rd C

    oo lin

    g Sy

    st em

    s

    www.Lytron.com • +1-781-933-730014

    SPECS 18

    GRAPHS 16

    SELECT 27

    Cooling capacities up to 11 kW

    Easy-access fill port

    Emergency Off (EMO) button (optional)

    Large, easy-to-read, controller display Process temperatures

    from -10°C to 35°C

    Reservoir-level indicator

    Seismic brackets (optional)

    Heavy-duty casters (two locking)

    RC006 – RC045

    RC095 – RC115

    Kodiak compressor-based recirculating chillers are the ideal solution when you need precise temperature control or cooling below ambient temperature. Kodiak chillers offer outstanding performance and high reliability as well as quiet operation and ease-of-use.

    • Precise temperature control: Our custom PID controller and advanced refrigeration control circuit ensure that the Kodiak maintains ±0.1°C (0.2°F) stability.

    • Quiet operation: The components inside the Kodiak have been performance-matched for quiet operation. In addition, vibration-isolation of the compressor (and pump in RC006–RC045) and foam padding on panels minimize vibration noise.

    • Many options and features: The Kodiak was designed for flexibility—a wide variety of pumps, controllers, and additional safety and monitoring features allow you to tailor a Kodiak to your specific application.

    • High reliability: We are so confident that our Kodiak chillers will provide years of trouble-free operation that we offer a 2-year warranty.

    • Advanced ergonomic design: Our chillers look as good as the equipment they cool. Our industry-leading industrial design is as functional as it is attractive.

    • CE certified and ITSNA tested to UL 61010A-1 (RC006 – RC045) or MET tested to UL 1995 (RC095–RC115)

    Custom Spotlight:

    Lytron’s custom products leverage existing standard products as well as previously designed custom products. Using these industry-proven technologies, we can reduce your time to market while giving you the customizations, quality, and reliability you need. This custom water-cooled chiller handles specialty cooling fluid and is MET and CE compliant.

    See page 8 for more custom cooling systems.

    89903_Lytron_Catalog_2011_Rev3:Lytron 2011 5/2/12 7:58 PM Page 14

  • Kodiak Standard Cooling System

    s Recirculating Chillers

    www.Lytron.com • +1-781-933-7300 15

    SPECS 18

    GRAPHS 16

    SELECT 27

    Low flow

    Circuit breaker

    Coolant supply

    Large capacity tank improves temperature stability

    Coolant return

    System drain

    IEC320 power inlet

    External customer contact

    RS232 port (optional)

    Manually adjustable flow valve (optional)

    Pump options available for your specific application

    Split-chassis, modular design for easy customization

    Compressor

    High-efficiency evaporator

    Vibration-isolating feet on compressor and pump

    Alarm

    Low level

    Pressure display

    Large alphanumeric display with temperature in °C or °F Over temperature

    Cooling on/off indicator

    Low temperature Alarm mute

    Cooling capacities up to 11 kW

    Four standard alarm LEDs with audible alarm to protect system

    Digital temperature and pressure display

    Large, easy to use coolant temperature arrows

    °C/°F toggle

    Scroll compressor reduces system noise and increases reliability

    Hot gas bypass valve provides for precise coolant temperature control and increased compressor life

    Long life stainless steel centrifugal pump – standard

    Flow switch protects pump from cavitation

    Optional 9 or 25 pin D-sub connectors for external communications link (free GUI available on www.Lytron.com)

    Four swiveled cushioned casters dampen shock

    SEMI S2 seismic package (optional)

    3/4" (19 mm) FPT coolant fittings

    Stainless steel mesh strainer protects

    system from foreign particulates in

    coolant

    10' (3 m) power cable (full length not shown)

    RC006 – RC045 RC095 – RC115

    89903_Lytron_Catalog_2011v3:Lytron 2011 5/2/12 7:09 PM Page 15

  • Performance GraphsKodiak St an

    da rd C oo

    lin g Sy st em

    s

    www.Lytron.com • +1-781-933-730016

    SPECS 18

    GRAPHS 16

    SELECT 27

    0

    0.5

    1.0

    1.5

    2.0

    5 10 15 20 25 30 35

    50 60 70 80 90

    2

    4

    6

    C o

    o lin

    g C

    ap ac

    it y

    (k W

    )

    Output Temperature (°C)1

    RC006-RC011 Performance °F kBTU

    hr

    RC006 60 Hz

    RC006 50 Hz RC009 50 Hz

    RC011 50 Hz

    RC011 60 Hz

    RC009 60 Hz

    0

    2.0

    4.0

    6.0

    8.0

    5 10 15 20 25 30 35

    50 60 70 80 90

    C o

    o lin

    g C

    ap ac

    it y

    (k W

    )

    Output Temperature(°C)1

    RC022-RC045 Performance

    25

    15

    5

    20

    10

    °F kBTU hr

    RC045 50 Hz

    RC045 60 Hz

    RC022 60 Hz

    RC022 50 Hz

    RC030 60 Hz

    RC030 50 Hz

    Thermal Performance Graphs

    1 Temperature represents output temperature of water assuming 20°C ambient air conditions. Performance subject to change due to variations such as fluid type or operating conditions.

    0

    2.0

    4.0

    6.0

    8.0

    10.0

    12.0

    14.0

    5 10 15 20 25 30 35

    50 60 70 80 90

    C o

    o lin

    g C

    ap ac

    it y

    (k W

    )

    Output Temperature (°C)1

    RC095 Performance °F

    10

    20

    40

    kBTU hr

    30

    60 Hz, 20°C Ambient

    50 Hz, 20°C Ambient

    60 Hz, 30°C Ambient

    50 Hz, 30°C Ambient

    0

    2.0

    4.0

    6.0

    8.0

    10.0

    12.0

    14.0

    5 10 15 20 25 30 35

    50 60 70 80 90 C

    o o

    lin g

    C ap

    ac it

    y (k

    W )

    Output Temperature (°C)1

    RC115 Performance °F

    10

    20

    40

    kBTU hr

    30

    60 Hz, 20°C Ambient

    60 Hz, 30°C Ambient

    50 Hz, 30°C Ambient

    50 Hz, 20°C Ambient

    89903_Lytron_Catalog_2011:Lytron 2011 4/26/12 4:07 PM Page 16

  • Kodiak Standard Cooling System

    s Performance Graphs

    www.Lytron.com • +1-781-933-7300 17

    SPECS 18

    GRAPHS 16

    SELECT 27

    10

    20

    30

    40

    50

    60

    70

    80

    90

    0 1 2 3 4 5

    1

    2

    3

    4

    5

    5 10 15

    Fl u

    id P

    re ss

    u re

    ( PS

    I)

    Water Flow Rate (gpm)

    Kodiak Positive Displacement Pumps2,3

    LPM Bar

    0

    BG/CG 60 Hz

    BG/CG 50 Hz

    BE/CE 60 Hz

    BE/CE 50 Hz

    BC/CC 60 Hz

    BC/CC 50 Hz

    BB/CB 60 Hz BB/CB 50 Hz

    0

    10

    20

    40

    50

    0 4 8

    5 10 15

    Fl u

    id P

    re ss

    u re

    ( PS

    I)

    Water Flow Rate (gpm)

    RC006-RC009 Centrifugal and Turbine Pumps LPM

    Bar

    1

    2

    3

    0

    30

    20 25

    2 6

    AA 60 Hz

    AA 50 Hz

    EC 60 Hz

    EC 50 Hz

    0

    10

    20

    40

    50

    0 2 4 6 8

    5 10 15

    Fl u

    id P

    re ss

    u re

    ( PS

    I)

    Water Flow Rate (gpm)

    RC011-RC022 Centrifugal and Turbine Pumps LPM

    Bar

    1

    2

    4

    5

    0

    30

    20 25

    60

    70

    90

    80

    3

    DA 60 Hz

    DA 50 Hz

    EC 60 Hz

    EC 50 Hz

    EB/FB 50 Hz

    EB/FB 60 Hz

    0

    10

    20

    40

    50

    0 2 4 6 8

    50 10 15

    Fl u

    id P

    re ss

    u re

    ( PS

    I)

    Water Flow Rate (gpm)

    RC030-RC045 Centrifugal and Turbine Pumps LPM

    Bar

    1

    2

    4

    30

    20 25

    60

    70

    90

    80

    3

    5

    DA 60 Hz

    DA 50 Hz

    EB/FB 50 Hz

    EB/FB 60 Hz

    System Pump Graphs1

    1 Includes pressure drop through chiller. See pumps overview on www.Lytron.com for guidance on selecting a pump.

    2 Pressure relief is factory set at 90 psi (6.2 bar). Other settings available upon request.

    3 BG/CG pumps can be operated at flow rates as low as 0.5 gpm (1.9 lpm) for the RC011 and RC022.

    0

    20

    40

    60

    100

    80

    0 2 4 6 8 1210 14

    5 45

    2

    4

    Fl u

    id P

    re ss

    u re

    ( PS

    I)

    Water Flow Rate (gpm)

    LPM Bar

    1

    3

    5

    6

    0 10 15 20 25 30 35 40

    Turbine 60 Hz

    Turbine 50 Hz

    Centrifugal 60 Hz

    Centrifugal 50 Hz

    RC095-RC115 Centrifugal and Turbine Pumps

    89903_Lytron_Catalog_2011v3:Lytron 2011 5/2/12 7:09 PM Page 17

  • Specifications and Part Number ConfigurationKodiak St an

    da rd C oo

    lin g Sy st em

    s

    www.Lytron.com • +1-781-933-730018

    SPECS 18

    GRAP