CP2000 for Biomass Plant Pump & Fan

7th Feb. 2013John ZuoIABG EMEA

Page 2: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

TABLE OF CONTENT

Remote Control in Industry

CP2000 Remote Control Solution

Reference Case

FAQ

Appendix

Page 3: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

Remote Control in Industry

• Remote Control generally is to control & monitor the site information in centralized room

based on EtherNet / IP or Modbus TCP.

switch

Elevator Conveyor Air-compressor Injection Molding Machine

Lighting HVAC

WebServer

Modbus TCP

ModbusEtherNet/IP

ModbusEtherNet/IP

Modbus TCPCentralized Room

Page 4: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

• Current Remote Control Solution

Adapter or Client SupplierAdapter or Client Supplier

Scanner or Server SupplierScanner or Server Supplier

SCADA Solution SCADA Solution

Delta has client option card for Modbus TCP and adapter option card for EtherNet/IP.

CMC-MOD01

CMC-EIP01

EN01+

CMC MOD01

A. Delta only can have EN01 module for Server in Modbus TCP.

B. Delta doesn’t have Scanner for EtherNet/IP yet.

No Solution

in Delta

Total Solution

Remote Control in Industry

Page 5: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

CP2000 Remote Control Solution

• CMC-MOD01

• CMC-EIP01

• Support 32 Modbus TCP Servers.

• Delta Own solution for server & client.

• Support only 1 Modbus TCP Server.

• Support 32 EtherNet / IP Scanners.

• Delta only has adapter card no scanner products.

Page 6: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

Reference Case

• One successful application at Biomass Plant in Italy

Page 7: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

Reference Case

• The system structure

WAGO PLC Centralized Room

Fan & Pump Site

Modbus TCP

CMC-EIP01

Parameter List

Page 8: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

FAQ

1. Can we use DCISoft for finishing the IP setting for this system ?

DCISOFT only can set IP for Delta Own products, so for WAGO PLC, we can’t

do that in DCISOFT. Hence, if the server is not Delta Products, please use the

server software for configuring IP to all products. That is better.

Besides, for DCISOFT, it only can set IP configuration to Delta product except

HMI, and can’t set common parameter of inverter like frequency source.

2. In this case, why can they use CMC-EIP01 for Modbus TCP?

CMC-EIP01 still can & only support 1 server in Modbus TCP. In this case, there is only

one server namely WAGO PLC in Modbus TCP, so CMC-EIP01 is OK for CP2000 to

communicate in Modbus TCP in this case.

Our customer planed to use CMC-MOD01, but no stock, so choose CMC-EIP01.

However, we still suggest if you can, please use CMC-MOD01 for Modbus TCP.

Page 9: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

FAQ

3. Is the C2000 the same setting as CP2000 in Modbus TCP ?

C2000 has the same setting as CP2000 in Modbus TCP for speed mode, so if

you know how to set CP2000, you can know C2000. Besides, C2000 can

support Torque control in Modbus TCP which CP2000 can’t support, so you

can also go to our public folder to download application note about it.

4. EtherNet/IP is better than Modbus TCP ?

EtherNet/IP can support more control protocols even including motion since it is

designed by AllenBradly. However, for common speed control, Modbus TCP is more

suitable for Delta since we have the server already. Of course, you still can use other

servers like WAGO in this case.

For EtherNet/IP, Delta CMC-EIP01 only support 2000H 2001H 2002H to be controlled.

Page 10: CP2000 for Biomass Plant Pump & Fan 7 th Feb. 2013 John Zuo IABG EMEA

Delta Confidential

Appendix

1. Please go to DEN Public Folder to download C2000 application notes < C2000 Modbus TCP

in speed mode>, < C2000 Modbus TCP in Torque mode>

2. Please go to 8-9 for knowing the EtherNet/IP information of C2000. Delta EtherNet