Download - NEXT-GEN BIOXYMOP
WASTEWATER TREATMENT
BIOXYMOP 6 PE WASTEWATER TREATMENT MICROSTATION
NEXT-GEN
Agrément Ministériel
N° 2017- 008
in a
ccord
ance with the Order
of 7th august 2009
NF EN 12586-3 + A + A2 co
mplian
t
ministerial approval
10 rue Richedoux 50480 SAINTE-MÈRE-ÉGLISE – FRANCE – Tél. +33(0)2 33 95 88 00 – Fax +33(0)2 33 21 50 75www.simop.fr – e-mail : [email protected] document. Dimensions (in mm) are given for information only and are subject to change without notice.
SIMOP
For more than thirty-five years, SIMOP has been developing and marketing solutions for domestic wastewater treatment.
It is thanks to this experience and after numerous tests that the BIOXYMOP Next-Gen was designed. This next-gen meets the standards in force (EN12566-3 and the decree of 7 September 2009) and is even easier to use and more efficient.
Based on the «IFAS» principle (Integrated Film Activated Sludge), the BIOXYMOP Next-Gen ensures a treatment allowing to reach exceptional purification performances.
DESCRIPTION
• Very low energy consumption
• Reduced operating and maintenance costs
• Monobloc
• Very low ground clearance • Shallow depth
• « Plug & Play » Electrical connection system
• Laying in ground water up to the stream
• Installation in green spaces or under roadways
• Good tolerance to load variations
• Odourless
BENEFITS
21
3
BIOXYMOP6 EP WASTEWATER TREATMENT MICROSTATION
READY TO USE
NEXT-GEN
DECANTER
3 m3XXL
MANUFACTURED& DESIGNED IN
FRANCE
10 rue Richedoux 50480 SAINTE-MÈRE-ÉGLISE – FRANCE – Tél. +33(0)2 33 95 88 00 – Fax +33(0)2 33 21 50 75www.simop.fr – e-mail : [email protected] document. Dimensions (in mm) are given for information only and are subject to change without notice.
SIMOP
BIOXYMOP next-genIS COMPOSED OF 3 COMPARTMENTSFOR 3 DISTINCT FUNCTIONS
OPERATION
A DECANTER OF 3 M3 : domestic wastewater flows into the primary settling tank. This pre-treatment allows for the retention of larger particles at the bottom and floating particles on the surface.
THE AERATION BASIN : the pre-treated effluent then passes through the aeration basin where dissolved pollution is eliminated by the purifying bacteria fixed on the free supports.
THE CLARIFIER : the treated effluent is separated from suspended solids. The AIRLIFT system allows the recirculation of effluents to the primary settling tank.
AIRLIFT TECHNOLOGY :
1
2
3
1 2 2 3
The treated effluent meets the requirements of standard EN12566-3 and the modified decree of 7th september 2009. Discharge of treated wastewater can be done in two models :
• through drainage and infiltration into the soil,
• by discharge into the superficial hydraulic medium, subject to compliance with the technical regulations in force.
BIOXYMOP6 EP WASTEWATER TREATMENT MICROSTATION
READY TO USE
NEXT-GEN
air blown by an air pump
Driving force caused by bubble movement and entraining the liquid
10 rue Richedoux 50480 SAINTE-MÈRE-ÉGLISE – FRANCE – Tél. +33(0)2 33 95 88 00 – Fax +33(0)2 33 21 50 75www.simop.fr – e-mail : [email protected] document. Dimensions (in mm) are given for information only and are subject to change without notice.
SIMOP
TECHNICAL DETAILS
RH2/4031 Screw-in extension 300 mm crossover every 50 mmKITMD/6027 Kit for remote compressor mountingREL4/6025 Exterior housing for compressor
B
A
GH
C
I
E
ØD
ØF
ENTRANCE
ØF
EXIT
Reference
dimensions en mm
usable volumeA B C ØD E(entrance)
ØF G(exit)
H I
BIOXYMOP 6027/06 1850 1912 2405 400 1550 100 1500 350 1940 5060 litres
OPTIONS
The BIOXYMOP Next-Gen microstation complies with the regulatory requirements imposed by the modified decree of 7th september 2009.
These performances are achieved under normal conditions of use, care and maintenance, in accordance with the instructions in the user’s guide and after a one-month start-up period.
PERFORMANCES
Parameters DBO5 DCO MES
Tests carried out with intakes (mg/l) : 316 733 320
Returns (%) 96 94 90
Discharges (mg/l) 12.6 73 19.2
require the order (mg/l) 35 - 30
BIOXYMOP6 EP WASTEWATER TREATMENT MICROSTATION
READY TO USE
NEXT-GEN
• The vat room is guaranteed for 10 years , if the installation and installation conditions have been respected.
• Electromechanical elements are guaranteed for 1 year under normal conditions of use.
10 rue Richedoux 50480 SAINTE-MÈRE-ÉGLISE – FRANCE – Tél. +33(0)2 33 95 88 00 – Fax +33(0)2 33 21 50 75www.simop.fr – e-mail : [email protected] document. Dimensions (in mm) are given for information only and are subject to change without notice.
SIMOP
INSTALLATION WITHOUT SPECIAL CONSTRAINTS
INSTALLATION WITH GROUND CONSTRAINTS AS :• HYDROMORPHIC • CLAYEY • WITH GROUNDWATER
INSTALLATION
SIMOP guarantees the treatment of domestic wastewater in accordance with the regulatory requirements in force at the time of installation of its BIOXYMOP micro-stations.
These performances are guaranteed under normal conditions of use, care and maintenance in accordance with the instructions in the user’s manual.
GUARANTEES
Top fill (60 cm maximum)
Side fill (sand) with water tank filling per 50 cm layer
10 cm sand bed
Top fill (60 cm maximum)
Side fill (sand) with water tank filling per 50 cm layer
Geotextile
Piezometer
10 cm sand bed
Reinforced Concrete Radius
Straps
BIOXYMOP6 EP WASTEWATER TREATMENT MICROSTATION
READY TO USE
NEXT-GEN
10 rue Richedoux50480 SAINTE-MÈRE-ÉGLISE
FRANCE
Tél. + 33 (0)2 33 95 88 00 Fax + 33 (0)2 33 21 50 75
www.simop.fr e-mail : [email protected]
SIMOP France SAS Capital of 1 370 000 eurosSIRET 754 040 707 00012
Distributed by :
Layo
ut
SIM
OP
Fran
ce S
AS
I
nove
mbe
r 201
7
I
DEP6
027-
C
Stormwater treatment• Rainwater recovery• Oil separators• Particulate decanters• Basin facilities
Wastewater treatment• On-Site sanitation < 20 PE• On-Site sanitation > 20 PE• Grease & starch pretreatment
Roads and networks• Floor products• Sanitation manholes • Pumping stations
SIMOP IS ALSO :
FOLLOW US ON
Find all our products on www.simop.fr
WASTEWATERTREATMENT
STORMWATERTREATMENT
ROADS &NETWORKS
Construction and Public Works
STORMWATER TREATMENTWASTEWATER TREATMENTROADS AND NETWORKS