ec type-examination certificate uk/0126/0137uk/0126/0137 mi-005 ec type-examination certificate...

16
Issue Date: Valid Until: Reference No: 30 November 2012 29 November 2022 TS0901/0030 Signatory: for P Dixon Chief Executive 0135 National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.bis.gov.uk/nmo UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In accordance with the requirements of the Measuring Instruments (Liquid Fuel and Lubricants) Regulations 2006 (SI 2006/1266) and the Measuring Instruments (Non- Prescribed Instruments) Regulations 2006 which implement, in the United Kingdom, Council Directive 2004/22/EC, this certificate of EC type-examination has been issued to: Gilbarco GmbH Ferdinand Henze Strasse 9 D-33154 Salzkotten Germany In respect of: Liquids other than water dispenser designated SK700-II family of dispensers Accuracy class: 0.5 Liquid fuels and Adblue 1.0 LPG

Upload: others

Post on 19-Mar-2020

68 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

Issue Date: Valid Until: Reference No:

30 November 2012 29 November 2022 TS0901/0030

Signatory: for

P Dixon Chief Executive

0135

National Measurement Office | Stanton Avenue | Teddington | TW11 0JZ | United Kingdom Tel +44 (0)20 8943 7272 | Fax +44 (0)20 8943 7270 | Web www.bis.gov.uk/nmo

UK/0126/0137

MI-005

EC type-examination certificate UK/0126/0137

issued by:

The National Measurement Office Notified Body Number 0126

In accordance with the requirements of the Measuring Instruments (Liquid Fuel and Lubricants) Regulations 2006 (SI 2006/1266) and the Measuring Instruments (Non-Prescribed Instruments) Regulations 2006 which implement, in the United Kingdom, Council Directive 2004/22/EC, this certificate of EC type-examination has been issued to:

Gilbarco GmbH Ferdinand Henze Strasse 9 D-33154 Salzkotten Germany

In respect of: Liquids other than water dispenser designated SK700-II family of dispensers

Accuracy class: 0.5 Liquid fuels and Adblue

1.0 LPG

Page 2: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

2/16

Descriptive Annex 1 INTRODUCTION The SK700-II family is a range of dispensers for use in attended or unattended mode. A number of alternative housings are included which are identified as:

SK700-II Endura alternative identification: SK700-II/Endura Frontier Europe alternative identification: SK700-II/Frontier EU IOD alternative identification: SK700-II/IOD Encore510 alternative identification: SK700-II/Encore510 397G alternative identification: SK700-II/397G Horizon alternative identification: SK700-II/Horizon Aral alternative identification: SK700-II/Aral 112 alternative identification: SK700-II/112

Example arrangements are shown in Figures 3-11. Further examples are held in the Documentation File. The dispensers described in this document are suitable for use with:

• liquid fuels including petroleum, ethanol blends, methanol blends, diesel, heating oil, biodiesel and biodiesel blends,

• liquefied petroleum gas (LPG),

• aqueous urea solution (Adblue),

The dispenser model name may identify the liquid type, e.g. SK700-II/Adblue, SK700-II/LPG. Example arrangements are shown in Figures 12-13. Measuring instruments associated with the liquid types above can share the same calculator, and optionally share the same enclosure. The measuring instruments can share the same calculator and housing as a compressed gas dispenser. 2 CHARACTERISTICS

Accuracy Class 0.5 Liquid fuels and Adblue 1.0 LPG

Mechanical Environment Class M2

Electromagnetic Environment Class

E1

Vmin liquid fuels 2 or 5 litres if Qmax ≤ 60lpm 2, 5 or 10litres if Qmax > 60lpm Often determined by national re-verification practices.

Vmin LPG 5 litres

Vmin Adblue 2 or 5 litres

Page 3: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

3/16

2.1 The ambient temperature range for a dispenser is limited to a range in which the characteristics of all individual components within the dispenser are valid. Similarly, the liquid temperature range for a dispenser is limited to a range in which the characteristics of all individual components are valid. 2.2 The overall characteristic of a measuring instrument (delivery circuit) is limited to a range in which the characteristics of all the individual components within the measuring instrument are valid. 2.3 Operation at -40°C is only valid if a heater is fitted to the electronics enclosure 2.4 Where two meters are used in parallel, Qmax = 2 x Qmax for an individual meter. 2.5 Qmin-Qmax for a measuring instrument, as marked on the dispenser nameplate, can be selected by Gilbarco providing that:

Qmax/Qmin ≥ 10 for liquid fuels Qmax/Qmin ≥ 5 for LPG Qmax/Qmin ≥ 4 for Adblue

and that there is no conflict with the characteristics of any component associated with that instrument.

Page 4: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

4/16

3 CONSTRUCTION 3.1 Prime Components and Characteristics The dispenser is constructed from any combination of the prime components listed in Table 1 providing there are no conflicting characteristics within the relevant Evaluation Certificates.

Table 1 Prime Component Summary

Manufacturer Type Evaluation

Certificate

Comments

Liq

uid

Fu

el

LP

G

Ad

blu

e

Meters

Gilbarco GmbH C+, V, V+ TC7144 Issued by NMI X

Gilbarco GmbH Ecometer TC7143 Issued by NMI X

Gilbarco GmbH C TC7141 Issued by NMI X

Gilbarco Veeder-Root V meter GB-1343 X

Gilbarco Veeder-Root C global & C+ global meters

GB-1360 X

Gilbarco GmbH K150 TC7142 Issued by NMI X

Endress+Hauser LPGmass DN15 TC7286 Issued by NMI X X

2A Engineering Prima SK12-001 ME Issued by SLM X

Gas Separators

Gilbarco GmbH GPU90 TC7146 Issued by NMI X

Gilbarco GmbH GPU140 TC7274 Issued by NMI X

Electronic Calculator

Gilbarco GmbH Sandpiper-2 TC7123 X X X

Gilbarco Veeder-Root Rose

GB-1467 Only used in volume-only dispensers

X

Gilbarco Veeder-Root Tulip GB-1368 X

Gilbarco GmbH ER112, EL112

TC7080 Issued by NMI. Only used in 112 model

X

Submerge Pumps

Red Jacket Not required Gas separator not

required X X

FE-Petro Not required Gas separator not

required X

Page 5: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

5/16

Table 2 Prime Component Characteristics

Ambient temp

Liquid temp

Viscosity range / fuel

Qmin Qmax Pmax

C+, V, V+ V meter C+ global meter

-10°C to +55°C

-10°C to +40°C

0.4mPa.s to 17mPa.s

1.6lpm 80lpm 3.5bar

C global meter C

-10°C to +55°C

-10°C to +40°C

0.4mPa.s to 17mPa.s

4lpm 80lpm 3.5bar

C+ global meter low temp version

-40°C to +55°C

-40°C to +40°C

0.4mPa.s to 17mPa.s

1.6lpm 80lpm 3.5bar

Ecometer -25°C to +55°C

-10°C to +50°C

0.4mPa.s to 17mPa.s

4lpm 80lpm 3.5bar

K150 meter -25°C to +55°C

-10°C to +50°C

0.4mPa.s to 17mPa.s

4lpm 130lpm 3.5bar

E+H Coriolis LPGmass DN15

-40°C to +55°C

-40°C to +55°C

- 2.4kg/min 130kg/min 100bar

2A Prima meter -25°C to +55°C

-10°C to +50°C

LPG 5lpm 50lpm 25bar

GPU90 -40°C to +55°C

-40°C to +55°C

0.4mPa.s to 1.1mPa.s

- 90lpm 1.9bar

GPU90 -40°C to +55°C

-40°C to +55°C

1.1mPa.s to 17mPa.s

- 90lpm 2.5bar

GPU140 -40°C to +55°C

-40°C to +55°C

1.1mPa.s to 8.0mPa.s

- 140lpm 3.5bar

Sandpiper-2 Rose Tulip ER112, EL112

-25°C to +55°C

- - - - -

Page 6: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

6/16

3.2 Self Service Devices The dispenser may be connected to the following self-service devices:

• any self-service device listed in Table 3 where the calculator supports the protocol, or

• any self-service device with a Parts Certificate where the communication protocol is stated in the Parts Certificate for the self-service device and in the Evaluation Certificate for the calculator.

Table 3 Self-service devices

Manufacturer Type Evaluation

Certificate

Comments

Gilbarco Passport Europe

PBox

TC7581 Issued by NMI

Gilbarco Autotank Outdoor Payment NC3/NP3 L/P/C

127612 Issued by SP

(Sweden)

Gilbarco Autotank Outdoor Payment NP-M3(OPT) NC-M3 CRIP (GS/SK) NP3-M3 NC3L-M3 (GS/SK) NP3-M4 NC3P-M4 NC3L-M4 (GS/SK)

FIT.10.A.ER.01 FIT.10.A.01

Issued by ITO (Finland)

Tokheim FuelPOS TC7343 Issued by NMI

Wayne Fusion SP 107023 Issued by SP

Scheidt u Bachmann TMS30 TC7596 Issued by NMI

Hectronic TA2331 GB-1286

Hectronic Heconomy A0445/4225/2012EC Issued by BEV

Hectronic Hecstar Hecfleet NT A0445/4226/2012EC Issued by BEV

BP Europe RAP Sustain TC7657 Issued by NMI

Orpak Systems Ltd Systor POS and OrPt OPT

GB-1381

3.2 Other Components and Arrangements Critical to Metrology 3.2.1 General 3.2.1.1 Where one meter feeds more than one hose circuit (for example Master-Satellite configurations), control valves ensure that a delivery cannot be made simultaneously from more than one hose circuit. 3.2.1.2 The combination of hose type and length is selected to ensure hose dilation does not result in a displayed quantity at the start of a transaction prior to the nozzle being operated.

Page 7: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

7/16

3.2.2 Liquid fuel dispensers 3.2.2.1 Where more than one meter shares an incoming product line, either in the same dispenser, or in the case of sites with submerged pumping units meters within other dispensers, non-return valve(s) are fitted to prevent reverse flow from each meter. 3.2.2.2 When one pump and gas separator feeds two meters which in turn feed separate hoses, a control valve is fitted in the hydraulic circuit associated with each meter. 3.2.3 LPG dispensers 3.2.3.1 A non-return valve is fitted in the liquid line between the vapour separator and the meter. 3.2.3.2 A differential valve is installed, and ensures that the liquid pressure is a minimum of 1 bar greater than the vapour pressure 3.2.3.3 A manometer is installed in the liquid line close to the meter and upstream of the differential valve. 3.2.3.4 For LPG installations where several dispensers share a common supply system, a control valve is installed in each meter circuit. 3.2.3.5 For LPG installations where several dispensers share a common supply system, and where the gas separator does not include a float mechanism, a non-return valve is installed in the each dispenser vapour return line 3.2.4 Adblue dispensers 3.2.4.1 A non-return valve is fitted in the liquid line ahead of the meter. 3.2.4.2. The installation provides a system to prevent the remote pump running dry. 3.3 Optional Components and Arrangements 3.3.1 Optional Chassis Construction 3.3.1.1 The electronics enclosure facia may be constructed of steel, aluminium, or plastic, or a combination of these materials, except where restricted by the calculator certificate. 3.3.1.2 The dispenser housing may be used for the construction of a satellite unit containing a hose and nozzle circuit fed from the hydraulics in a remote master dispenser. This unit may optionally house a display repeating the transaction information shown on the master. The satellite is deemed to be a nozzle of the master unit. Two satellites may share a single housing.

Page 8: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

8/16

3.3.2 Optional Features

• Addition of Gilbarco Veeder-Root vapour recovery systems, using electronics considered as part of the calculator evaluation.

• Addition of electronics for payment at the dispenser

• Electronic calibration

• Temperature compensation

• Heaters for the electronics enclosure for low temperature operation

• Preset, by self-service device, or by local user interface

• Master-Satellite operation for diesel/gasoil dispensers

• Delivery flowrate selection either by nozzle selection or by pushbutton

• Volume only indicator

• On LPG dispensers, if the delivery button/switch is released, the delivery may be continued within a programmable time of up to 15 seconds without zero setting of the calculator

• Other options listed in the component evaluation certificates 3.3.3 Component options

• Control valves may be single stage on/off, two stage for preset transactions, or proportional providing continuously variable flowrates

• Hoses and nozzles are as described in the technical file supporting this certificate.

• Vapour recovery systems are as described in the technical file supporting this certificate.

• Hydraulic arrangements of the prime components are as described in the technical file supporting this certificate.

3.3.4 Options not critical to Metrology. 3.3.4.1 The following items may be included within the hydraulic circuits:

• Shear valves

• Non-return valves separate from the pump and gas separator

• Swivels and or safety breaks in the hose assembly circuit

• Sightglasses for non-metrological purposes in the hose assembly circuit

• Mechanical totalisers

• Additional manometers on LPG dispenser 3.3.4.2 The following items may be included within the electronics housing without being included in component evaluation certificates

• Any electronics not associated with the sales transaction and not connected to circuits of the calculator, and which will not impact the EMC characteristics of the enclosure.

Page 9: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

9/16

4 APPROVAL CONDITIONS The certificate is issued subject to the following conditions: 4.1 Markings 4.1.1 Markings are in accordance with the WELMEC Guide 10.5 Issue 1. An example is shown in Figure 1. Initial verification labels including the CEM mark are added to this nameplate; but may be removed at subsequent field verifications. The height of the CE mark and the rectangle containing the letter “M” and year code are 5mm minimum. 4.1.2 The markings and inscriptions shall fulfil the requirements of Paragraph 9 of Annex I of the Directive 2004/22/EC. 4.2 Data Sheet 4.2.1 The datasheet format is in accordance with the WELMEC Guide 10.5 Issue 1. An example is shown in figure 2. 4.3 Displays and Legends 4.3.1. Displays and legends are configured to meet the requirements of the country of installation. The text associated with the volume and price is greater than 10mm high. The text associated with unit price(s) is greater than 4mm high 4.3.2 Text is included on or near the primary display to indicate the minimum delivery for the dispenser. 4.3.3 Where a temperature compensation system is employed, text is added on or near the primary display to indicate that the volume is “at 15°C”. Alternative words may be used to deal with national or language requirements. 5 LOCATION OF SEALS 5.1 Securing is detailed in the Documentation Files for the individual components. 5.2 Components may additionally be sealed to the dispenser frame, or alternatively, may be specifically listed by serial number on a datasheet which remains with the dispenser in the calculator enclosure. 5.3 On LPG dispensers, the pressure calibration screw of the differential valve is sealed, and the differential valve is sealed against removal from the dispenser. Any mechanical valves in the vapour return line are sealed in the open position.

Page 10: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

10/16

6 SUPPORTING DOCUMENTATION 6.1 Documentation file for SK700-II is held on file TS0901/0030/2/0001 7 ALTERNATIVES 7.1 There are as yet no alternatives 8 ILLUSTRATIONS Figure 1 Nameplate – typical arrangement of English version Figure 2 Datasheet – typical arrangement of English version Figure 3 SK700-II – typical arrangement Figure 4 Endura – typical arrangement Figure 5 Frontier Europe – typical arrangement Figure 6 IOD – typical arrangement Figure 7 Encore 510 – typical arrangement Figure 8 397G – typical arrangement Figure 9 Horizon – typical arrangement Figure 10 Aral – typical arrangement Figure 11 112 – typical arrangement Figure 12 LPG dispenser – typical arrangement Figure 13 Adblue dispenser – typical arrangement 9 CERTIFICATE HISTORY

ISSUE NO. DATE DESCRIPTION

UK/0126/0137 30 November 2012 Type examination certificate first issued.

Page 11: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

11/16

Figure 1 Nameplate – typical arrangement of English version

Manufacturing

address

One nameplate per

side on 2-sided

dispensers

Page 12: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

12/16

Figure 2 Datasheet – typical arrangement of English version

Page 13: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

13/16

Figure 3 SK700-II – typical arrangement

Figure 4 Endura – typical arrangement

Figure 5 Frontier Europe – typical arrangement

Page 14: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

14/16

Figure 6 IOD – typical arrangement

Figure 7 Encore 510 – typical arrangement

Figure 8 397G – typical arrangement

Page 15: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

15/16

Figure 9 Horizon – typical arrangement

Figure 10 Aral – typical arrangement

Figure 11 112 – typical arrangement

Page 16: EC type-examination certificate UK/0126/0137UK/0126/0137 MI-005 EC type-examination certificate UK/0126/0137 issued by: The National Measurement Office Notified Body Number 0126 In

16/16

Figure 12 LPG dispenser – typical arrangement

Figure 13 Adblue dispenser – typical arrangement

©Crown Copyright 2012 NATIONAL MEASUREMENT OFFICE