electrospeed gcs 3 indoor variable speed...
TRANSCRIPT
OVERVIEW| bakerhughes.com
Applications
Offshore platforms
Motor Control Centers (MCC)
Arctic houses
Any indoor application
Features and benefi ts
MaxStart™ software for hard-start
applications
– Delivers best-in-class starting
characteristics in harsh environments
MaxPoint™ software for frequency
sweep capabilities
– Maximizes production by ensuring
minimal shock to the reservoir during
startup and rate-change events
Optimized power converter (standard)
– Ensures low impact on input power
system required by power companies
Plug-and-play capability for sensors
– User-friendly system provides automated
format/visibility of information
• Optimizes ESP performance
• Maximizes production
GCS with enhanced outdoor
visibility screen
– Provides easy access and control of
information during setup and operation
– Includes event and trending capabilities
NEMA 1 and IP30 enclosure
– Delivers IP30 safety and protection
(greater safety than IP2x) with improved
cooling for indoor applications
Motor torque control
– Increases ESP system run life by
preventing over-torque conditions on
the downhole equipment
Since 1986, the Baker Hughes Electrospeed™
variable speed drive (VSD) has consistently
set new performance standards. Innovations
incorporated into the fi fth-generation
Electrospeed graphical control system (GCS) 3
VSD signify a step change in electrical
submersible pumping (ESP) system control and
reliability while providing the most dependable
surface control systems in the industry.
The Baker Hughes Electrospeed GCS 3 includes
several innovative software additions that
protect the downhole ESP system from power
system interruptions, give operators optimum
startups in hard-start conditions such as heavy
oil applications, and allow a programmable
setpoint for gradual ramp up of production to
ensure minimal shock to the reservoir.
The GCS provides a user-friendly interface to
program and launch software features. The
GCS interface records, logs, and communicates
data from the drive and from any downhole
monitoring system to a laptop, SCADA, satellite
or Baker Hughes’s Vision™ service. These state-
of-the-art VSD capabilities provide operators
with the highest level of ESP system control to
optimize well and fi eld performance.
The Electrospeed GCS 3 is the only VSD with a
choice of output waveforms, ranging from the
standard ESP output to sine-wave output with
our fi ltered pulse-width modulation (FPWM™)
system. Baker Hughes also offers 6-pulse,
12-pulse, and 24-pulse GridSync™ converter
options. For areas where power companies
require IEEE compliance, GridSync converter
Electrospeed GCS 3 Indoor Variable Speed DriveProtect your ESP system with innovative software
OVERVIEW
Electrospeed, Vision, FPWM, GridSync, MaxStart, and MaxPoint are trademarks of Baker Hughes Incorporated.
Disclaimer of Liability: This information is provided for general information purposes only and is believed to be accurate as of the date hereof; however, Baker Hughes Incorporated and its affi liates do not make any warranties or representations of any kind regarding
the information and disclaim all express and implied warranties or representations to the fullest extent permissible by law, including those of merchantability, fi tness for a particular purpose or use, title, non-infringement, accuracy, correctness or completeness of the
information provided herein. All information is furnished “as is” and without any license to distribute. The user agrees to assume all liabilities related to the use of or reliance on such information. BAKER HUGHES INCORPORATED AND ITS AFFILIATES SHALL NOT BE
LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER INCLUDING BUT NOT LIMITED TO ITS NEGLIGENCE.
© 2013 Baker Hughes Incorporated. All rights reserved. 39738 11/2013
Indoor (NEMA 1 IP30*) Selection Guide
1 6-Pulse: The industry standard for applications without harmonics requirement.
2 12-Pulse Dual Switch: For applications with harmonic concerns when phased shifted power is applied directly to the input. Requires phase shift input transformer.
3 12-Pulse Power Distribution Block (no switch): For applications with harmonic concerns when input power is externally switched. Requires phase shift input transformer.
4 Recording Ammeter: For those who still prefer traditionalrecording methods.
5 Auxiliary 115 volts: Supplies 275 VA.6 Integration of Centinel or WellLift surface electronics into VSD for
seamless operation.7 RS-485 and RS-232 are standard; a VCI-42 module is available
for RS-422. 8 I/O Module: Up to three I/O Modules may be used (only two with the
FPWM option). Each module has the following I/O: (2) Analog inputs; (2) Analog outputs; (3) Digital inputs; (3) Digital outputs.
9 Brass Gland Plate: Removable gland plate provides the power entrance to the power J box. Brass provides a nonmagnetic gland plate (required when the field wiring is done with single conductors through an opening).
10 Data Card: PCMCIA and Compact Flash.
11 CE Options: A special trip coil located in the input breaker allows for removal of power to the drive for an E-stop condition.
12 IP20 Shielding: Lexan shields added to protect personnel from exposure to electrical components when the door is open.
13 Euro Heater: Small compact heater with an integral thermostatand blower that does not expose personnel to the more typical strip heater.
14 Wire Markers: Used to easily identify wire terminations meeting special requirements.
15 IEEE-519 compliant 24-pulse converter configuration. 66-519kVA sizes will be in the 4000 frame size. Requires 24-pulse phase-shift input transformer.
16 FPWM: Filtered PWM provides near sinusoidal wave to the motor.17 MOV: Surge suppressor that protects the unit in the event of
excessive transient voltages. Standard with NEMA 4 enclosures.18 Language Option: English, Russian, and Spanish are included in
current software. Other languages available upon request.19 RDCM Sensor Options: Remote Device Communication Module
interface for digital interface to third-party instrumentation to maintain certification.
* IP stands for “Ingress Protection” as determined by International Electrotechnical Commission Standard 60529. This standard provides designations for levels of industrial enclosure protection.
6-Pulse1
12-Pulse, Dual Switch2
12-Pulse, Power Dist. Switch3
Recording Ammeter4
115V Aux. Power5
Down Hole Gauging6
SCADA interface7
I/O Module (3 Max.)8
Brass Gland Plate9
Data Logging10
CE Option11
IP 20 Shielding12
CE Heater13
Wire Markers14
24P GridSync™ IEEE-51915
Sine Wave-FPWM™ Output16
Paint Options
Surge Suppressor/MOV17
Language Option18
RDCM Sensor Interface19
PLC Programming
Special Communications
Medium Voltage
Control Room Systems
Run Light Option
Shut Down Light Option
kVA@480V
2000 Series 4000 Series 8000 Series 9000 Series
Standard NEMA1 Unit: 6-pulse, carbon steel enclosure, beige, graphic display, stainless steel fasteners and door hinges
Standard Product Options Special Product Options
Model
Carbon Steel Enclosure
Stainless Steel Enclosure
Stan
dard
Opt
ions
Spec
ial O
ptio
ns
20602075210021252150220022504300435044004500860087008800890093119313931594179420
1150135015501750
624
748873
325
390454
8366
111130163
200260
519
1000
2000
meets IEEE 519-1992 recommended practice
for placing nonlinear loads on power systems.
The Electrospeed GCS 3 VSD is available in a
NEMA1/IP30 enclosure for indoor installations.
It is built with the same quality and durability as
our NEMA 4 outdoor drives, and is certifi ed in
the United States, Canada, and Europe.
With more than 50 years of engineering
expertise in the development of advanced
applications, Baker Hughes is the only ESP
system provider that designs and manufactures
its own line of VSDs specifi cally engineered
for the harsh environments and challenging
applications in the oil and gas industry.
For seamless integration of the entire ESP
production system, Baker Hughes is your single
point of contact.
Contact your Baker Hughes representative or visit
www.bakerhughes.com/artifi cial-lift today to fi nd
out how the Electrospeed GCS 3 VSDs can help
improve your ESP system control and reliability.