general demolition notes +b a - cambridge/media/files/cdd/zoningdev...general demolition notes 1....

32
D W DW 1 2 3 5 6 7 8 A C B Multi-Purpose Room Stair A ST-A1 Elevator 1 Elevator 2 Stair B ST-B1 Men Women Unisex Kitchen Vestibule Coat Room Vestibule Security Mail Lobby Kitchen Stair C Lift Reception Lobby Office Open Office Unisex Men Women Printing Room A/C Room Office 15 19 20 1 4 21 5 7 1 9 5 4 4 9 2 2 4 23 4 1 4 4 9 1 2 2 4 9 9 9 4 9 9 4 2 1 4 2 27 27 27 27 1 4 4 1 25 1 4 19 4 1 4 1 4 4 1 4 4 4 1 1 22 22 22 22 9 9 4 1 1 4 2 1 1 29 2 9 9 22 2 7 25 1 2 2 30 28 4 1 2 1 4 1 4 2 9 4 22 2 9 4 22 22 31 31 31 31 9 4 32 19 19 19 19 2 1 2 2 5 5 5 33 4 4 2 4 4 1 4 4 4 4 1 6 20 48 48 4 48 48 1 7' - 5" 50 51 51 - --- 56 56 D 1 D300 2 D300 3 D300 4 D300 5 D300 6 D300 16 16 20' - 0" 14' - 8" 10' - 0" 26 22 22 15 SEE C100 FOR SITE DEMOLITION 62 4 26 63 63 63 63 63 63 63 63 63 12 A550 GENERAL DEMOLITION NOTES 1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALL LOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENT FINISHES, FRAMING, FASTENERS, ETC... 2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TO REMAIN AT COMPLETION. 3. ALL ITEMS SLATED FOR REMOVAL ARE SHOWN DASHED. DEMOLITION KEYNOTE TAGS INDICATE TYPICAL REMOVALS. 4. REFER TO PHASING PLANS FOR PROJECT SEQUENCING. 5. ADDITIONAL DEMOLITION INFORMATION SPECIFIC TO TRADE IS IDENTIFIED WITHIN SITE, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL & FIRE PROTECTION DRAWINGS. 6. WORK AREAS & SPACES AVAILABLE TO TENANTS TO BE CLEANED DAILY. 7. REFER TO A400 ENLARGED PLAN SERIES FOR DEMOLITION SPECIIFIC TO EXISTING UNITS. UNIT TYPES 6, 9 & 10 ARE NEW & THE DEMO FOR THOSE INSTANCES IS ON D102. 8. EXISTING FLOORING IN ALL WORK AREAS TO BE REMOVED DOWN TO THE CONCRETE DECK. REMOVALS TO INCLUDE BUT NOT LIMITED TO VINYL COMPOSITION TILE, CARPET, SHEET FLOORING, CERMAIC TILE, TRANSITIONS, ADHESIVES & MASTICS, UNDERLAYMENT, MORTAR BEDDING. 9. REFER TO D202 FOR ENLARGED DEMOLITION ELEVATIONS OF LOWER FLOORS ARCHITECT PROJECT NAME CLIENT PROJECT TEAM DRAWING TITLE DRAWING INFORMATION DRAWING NUMBER Bargmann Hendrie + Archetype, Inc. 300 A Street Boston, MA 02210 617 350-0450 Tel 617 350-0215 Fax www.bhplus.com Copyright BH+A, Inc. DATE OF ISSUE DESCRIPTION SCALE DRAWN BY PROJECT # FILE NAME + a bh Manning Apts.rvt STRUCTURAL CONSULTANT DM Berg Consultants, PC 100 Crescent Road, Suite 1A Needham, MA 02494 718-444-5156 Tel 718-444-5157 Fax www.dmberg.com MECHANICAL, PLUMBING, & FIRE PROTECTION CONSULTANT VAV International, Inc. 400 W. Cummings Park, Suite 4700 Woburn, MA 01801 781-935-7228 Tel 781-935-1822 Fax www.vavint.com ELECTRICAL CONSULTANT Nangle Engineering Incorporated 32 Prince Street Danvers, MA 01923 978-777-7650 Tel 978-777-7653 Fax www.nangleengineering.com LANDSCAPE ARCHITECT Hammer+Walsh Design Inc. 300 A Street Boston, MA 02210-1620 617-439-0125 Tel 617-439-0126 Fax CIVIL CONSULTANT Design Consultants, Inc. (DCI) 120 Middlesex Avenue, Suite 20 Somerville, MA 02145 617-776-3350 Tel 617-776-7710 Fax 362 Green Street Cambridge, MA 02139 617-864-3020 Tel 616-868-5372 Fax www.cambridge-housing.org 1/8" = 1'-0" D : \ R e v i t \ M a n n i n g A p a r t m e n t s - r 2 0 1 4 _ a h o n s a k e r . r v t 1 0 / 9 / 2 0 1 5 3 : 4 5 : 4 6 P M D101 1st Floor Demolition Plan Author 2896 Frank J. Manning Apartments 237 Franklin Street, Cambridge, MA 02139 Cambridge Housing Authority A u t h o r 1 1ST FLOOR DEMOLITION PLAN N Demolition Keynotes Key Key Note 1 Remove entire partition; including but not limited to gypsum board, studs, CMU, concrete, fasteners, finishes, building utilities within partition. 2 Remove gypsum wall board and finishes from existing furring wall; channels and insulation, are to remain. 4 Remove door & frame in its entirety, including but not limited to door, frame, sidelight / glass, anchors, fasteners, finishes, hardware. 5 Remove all plumbing fixtures in their entirety, including but not limited to fixture body, fasteners, supply & waste connections. 6 Remove all floor finishes in their entirety down to the original deck, including but not limited to cermaic tile, vinyl composition tile, sheet flooring, mastic & adhesives, underlayment. Typical for Project in all areas. 7 Remove kitchen cabinets, counters & appliances in their entirety, including but not limited to cabinet bodies & base, furring, fasteners, hardware. 9 Remove windows, storefront, curtainwall & louvers, including but not limited to window, louver, sub sill, blocking & shims, fasteners, sealant, backer rod & flashing. Typical at all instances. 15 Remove concrete site wall, including but not limited to concrete, reinforcing, footers. 16 Remove concrete site stair in its entirety, including but not limited to treads & risers, handrails, fasteners, coordinate limits with Structural Drawings. 19 Remove guardrail/handrail in its entirety, including but not limited to guardrail, handrails, fasteners, and precast concrete panels at balconies. 20 Remove pavers, including but not limited to all underlayment, pedestal or support blocking, paver field perimeter trim, waterproofing, etc down to existing concrete. Demolition 21 Remove toilet partitions entirely, including but not limited to partitions, hardware, toilet accessories, framing. 22 Remove cored asbestos panel. Refer to Hazardous Materials specifications. Remove in full panels to provide opening required. 23 Remove mailbox assembly in its entirety, including but not limited to mailboxes, framing, fasteners, finishes. 25 Remove all Food Service Equipment, including but not limited to equipment bodies, fasteners, power/supply/waste lines & connections. 26 Remove portion of concrete wall. Refer to Structural drawings for removal information. Coordinate with drawing D300 and Architecturals for dimensions. Sawcut opening. 27 Remove heater cabinet assembly, included but not limited to mechanical equipment, grilles, framing, fasteners, finished enclosure. 28 Remove entirety of millwork installation, including but not limited to plastic laminate assemblies, cabinets, framed half walls, counters, fasteners, concealed electrical lines. 29 Remove interior stair in its entirety, including but not limited to structural support framing, stringer, treads & risers, handrail/guardrail, finishes, fasteners. 30 Remove lift in its entirety, including but not limited to lift body, power supply connection, foundation, framing, suspended pit assembly & finishes. 31 Remove bollard in it entirety, including but not limited to pipe & concrete infill, foundation. 32 Remove mechanical unit & fence enclosure, including but not limited to equipment body, concrete pad, supply & waste lines & connections. 33 Remove electrical conduit encasement. 48 Remove outside run handrails at Stairs A & B in their entirety, including but not limited to pipe, brackets, fasteners, sealant. Patch holes in walls where fasteners have been removed. Interior run handrail to remain. 50 Remove concrete curb down to top of existing adjacent slab, to extent shown on plan. Demolition 51 Remove concrete curb down to allow for new installation. Refer to Structural Drawings for additional information. Demolition 56 Cut existing floor for 24" diameter chute installation. Refer to A417 for layout information. 62 Existing Entry Intercom System remove and relocate for temporary use. 63 Remove Cementious Soffit Material and Related Framing. ISSUED FOR: SPECIAL PERMIT APPLICATION OCTOBER 14, 2015 SPECIAL PERMIT APPLICATION L

Upload: truongnga

Post on 19-Mar-2019

224 views

Category:

Documents


0 download

TRANSCRIPT

DW

DW

1 2 3 5 6 7 8

A

C

B

Multi-PurposeRoom

Stair A

ST-A1

Elevator 1 Elevator 2

Stair B

ST-B1

Men Women Unisex

Kitchen VestibuleCoat

Room

VestibuleSecurity

Mail

Lobby

Kitchen

Stair C

Lift

ReceptionLobbyOffice

OpenOffice

Unisex Men Women

PrintingRoom

A/CRoom

Office

15

19 20

14

215

71

9

5

4

4 9

2

24

23

4 1

4 4

9

1

2

2

49

9

9 4

9

94

2

1

4

2

27

2727

27

1

4

4 1

25

1

4

19

4

1

4

1

4

4

1

4

4

4

1

1

22

22

22

22

9

9

4

1

1

4

2

1

1

29

2

9 9

22

27

25

1

2 2

30

28

41

2

14

14

2

94 22

2

94 22 22

31

31

31

31

9

4

32

1919

19

19

2

1

2

25

5

5

33 4

4

2

4 4

1

4 4

4

4

1

6

20

48

48 4

48

481

7' - 5"

50

51

51

----

56

56

D

1D300

2D300

3D300

4D300

5D300

6D3001616

20' - 0" 14' - 8" 10' - 0"

2622

22

15

SEE C100 FORSITE DEMOLITION

62

4

26

6363 63

63

63 63

63

63

63

12A550

GENERAL DEMOLITION NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCHALL LOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OFADJACENT FINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. ALL ITEMS SLATED FOR REMOVAL ARE SHOWN DASHED. DEMOLITIONKEYNOTE TAGS INDICATE TYPICAL REMOVALS.

4. REFER TO PHASING PLANS FOR PROJECT SEQUENCING.

5. ADDITIONAL DEMOLITION INFORMATION SPECIFIC TO TRADE ISIDENTIFIED WITHIN SITE, STRUCTURAL, MECHANICAL, PLUMBING,ELECTRICAL & FIRE PROTECTION DRAWINGS.

6. WORK AREAS & SPACES AVAILABLE TO TENANTS TO BE CLEANEDDAILY.

7. REFER TO A400 ENLARGED PLAN SERIES FOR DEMOLITION SPECIIFICTO EXISTING UNITS. UNIT TYPES 6, 9 & 10 ARE NEW & THE DEMO FORTHOSE INSTANCES IS ON D102.

8. EXISTING FLOORING IN ALL WORK AREAS TO BE REMOVED DOWN TOTHE CONCRETE DECK. REMOVALS TO INCLUDE BUT NOT LIMITED TO VINYLCOMPOSITION TILE, CARPET, SHEET FLOORING, CERMAIC TILE,TRANSITIONS, ADHESIVES & MASTICS, UNDERLAYMENT, MORTARBEDDING.

9. REFER TO D202 FOR ENLARGED DEMOLITION ELEVATIONS OF LOWERFLOORS

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

1/8" = 1'-0"

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:45

:46

PM

D101

1st FloorDemolition Plan

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1 1ST FLOOR DEMOLITION PLAN

N

Demolition Keynotes

Key Key Note

1 Remove entire partition; including but not limited to gypsum board, studs, CMU, concrete, fasteners, finishes, building utilities within partition.2 Remove gypsum wall board and finishes from existing furring wall; channels and insulation, are to remain.4 Remove door & frame in its entirety, including but not limited to door, frame, sidelight / glass, anchors, fasteners, finishes, hardware.5 Remove all plumbing fixtures in their entirety, including but not limited to fixture body, fasteners, supply & waste connections.6 Remove all floor finishes in their entirety down to the original deck, including but not limited to cermaic tile, vinyl composition tile, sheet

flooring, mastic & adhesives, underlayment. Typical for Project in all areas.7 Remove kitchen cabinets, counters & appliances in their entirety, including but not limited to cabinet bodies & base, furring, fasteners,

hardware.9 Remove windows, storefront, curtainwall & louvers, including but not limited to window, louver, sub sill, blocking & shims, fasteners, sealant,

backer rod & flashing. Typical at all instances.15 Remove concrete site wall, including but not limited to concrete, reinforcing, footers.16 Remove concrete site stair in its entirety, including but not limited to treads & risers, handrails, fasteners, coordinate limits with Structural

Drawings.19 Remove guardrail/handrail in its entirety, including but not limited to guardrail, handrails, fasteners, and precast concrete panels at balconies.20 Remove pavers, including but not limited to all underlayment, pedestal or support blocking, paver field perimeter trim, waterproofing, etc down

to existing concrete. Demolition21 Remove toilet partitions entirely, including but not limited to partitions, hardware, toilet accessories, framing.22 Remove cored asbestos panel. Refer to Hazardous Materials specifications. Remove in full panels to provide opening required.23 Remove mailbox assembly in its entirety, including but not limited to mailboxes, framing, fasteners, finishes.25 Remove all Food Service Equipment, including but not limited to equipment bodies, fasteners, power/supply/waste lines & connections.26 Remove portion of concrete wall. Refer to Structural drawings for removal information. Coordinate with drawing D300 and Architecturals for

dimensions. Sawcut opening.27 Remove heater cabinet assembly, included but not limited to mechanical equipment, grilles, framing, fasteners, finished enclosure.28 Remove entirety of millwork installation, including but not limited to plastic laminate assemblies, cabinets, framed half walls, counters,

fasteners, concealed electrical lines.29 Remove interior stair in its entirety, including but not limited to structural support framing, stringer, treads & risers, handrail/guardrail, finishes,

fasteners.30 Remove lift in its entirety, including but not limited to lift body, power supply connection, foundation, framing, suspended pit assembly &

finishes.31 Remove bollard in it entirety, including but not limited to pipe & concrete infill, foundation.32 Remove mechanical unit & fence enclosure, including but not limited to equipment body, concrete pad, supply & waste lines & connections.33 Remove electrical conduit encasement.48 Remove outside run handrails at Stairs A & B in their entirety, including but not limited to pipe, brackets, fasteners, sealant. Patch holes in

walls where fasteners have been removed. Interior run handrail to remain.50 Remove concrete curb down to top of existing adjacent slab, to extent shown on plan. Demolition51 Remove concrete curb down to allow for new installation. Refer to Structural Drawings for additional information. Demolition56 Cut existing floor for 24" diameter chute installation. Refer to A417 for layout information.62 Existing Entry Intercom System remove and relocate for temporary use.63 Remove Cementious Soffit Material and Related Framing.

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

1 2 3 5 6 7 8

A

C

B

Crafts Room Office

Men Women

Stair A

ST-A2

Elevator 1 Elevator 2

Stair B

ST-B2

CommonsRoom

TV / Lounge

Lobby

ElevatorLobby

Office

Men WomenChairStorage

BoardMeetingRoom

Stair C

Lift

Office ExecutiveDirector

ConferenceRoom

AssistantExecutiveDirector

Women

Men

Unisex

StaffLounge

Office Office

Office

Office

A/CRoom

Laundry

9

2

4

1

4

9 4 4

9

1

9

2

1

4

9

1

9

1

4

29

1

30

34 34

1

4

4

1 4

1

9 22

949

1

4

44 41 49 9

1

1

4

41

1

4

4

1

5

5

2222

1

22

4 1 4

1

4

1 4

1

4

1

1 4

2

1

4

2

2

1

4

1

9 22

4

1 4

9 22 9

1

14

4

1

1

2

1

1

4

4

1

1

4

2

1

4

2

9 22

1 1

14

1

1

444

2

1

1

1

1

44

4

22

41

14

1

9 9

2

2

6

6

22

22

448

48

4 48

481

4

26 26 26 264

4

4

5119

20Terrace

56

D

1D300

2D300

3D300

4D300

5D300

6D300

9

Louver

26

Alternate #1Only

6' - 0"8' - 0"

4

38

63 63

63 63

63

63

GENERAL DEMOLITION NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCHALL LOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OFADJACENT FINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. ALL ITEMS SLATED FOR REMOVAL ARE SHOWN DASHED. DEMOLITIONKEYNOTE TAGS INDICATE TYPICAL REMOVALS.

4. REFER TO PHASING PLANS FOR PROJECT SEQUENCING.

5. ADDITIONAL DEMOLITION INFORMATION SPECIFIC TO TRADE ISIDENTIFIED WITHIN SITE, STRUCTURAL, MECHANICAL, PLUMBING,ELECTRICAL & FIRE PROTECTION DRAWINGS.

6. WORK AREAS & SPACES AVAILABLE TO TENANTS TO BE CLEANEDDAILY.

7. REFER TO A400 ENLARGED PLAN SERIES FOR DEMOLITION SPECIIFICTO EXISTING UNITS. UNIT TYPES 6, 9 & 10 ARE NEW & THE DEMO FORTHOSE INSTANCES IS ON D102.

8. EXISTING FLOORING IN ALL WORK AREAS TO BE REMOVED DOWN TOTHE CONCRETE DECK. REMOVALS TO INCLUDE BUT NOT LIMITED TO VINYLCOMPOSITION TILE, CARPET, SHEET FLOORING, CERMAIC TILE,TRANSITIONS, ADHESIVES & MASTICS, UNDERLAYMENT, MORTARBEDDING.

9. REFER TO D202 FOR ENLARGED DEMOLITION ELEVATIONS OF LOWERFLOORS

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

1/8" = 1'-0"

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:45

:56

PM

D102

2nd FloorDemolition Plan

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1 2ND FLOOR DEMOLITION PLAN

N

Demolition Keynotes

Key Key Note

1 Remove entire partition; including but not limited to gypsum board, studs, CMU, concrete, fasteners, finishes, building utilities within partition.2 Remove gypsum wall board and finishes from existing furring wall; channels and insulation, are to remain.4 Remove door & frame in its entirety, including but not limited to door, frame, sidelight / glass, anchors, fasteners, finishes, hardware.5 Remove all plumbing fixtures in their entirety, including but not limited to fixture body, fasteners, supply & waste connections.6 Remove all floor finishes in their entirety down to the original deck, including but not limited to cermaic tile, vinyl composition tile, sheet flooring, mastic & adhesives,

underlayment. Typical for Project in all areas.9 Remove windows, storefront, curtainwall & louvers, including but not limited to window, louver, sub sill, blocking & shims, fasteners, sealant, backer rod & flashing.

Typical at all instances.19 Remove guardrail/handrail in its entirety, including but not limited to guardrail, handrails, fasteners, and precast concrete panels at balconies.20 Remove pavers, including but not limited to all underlayment, pedestal or support blocking, paver field perimeter trim, waterproofing, etc down to existing concrete.

Demolition22 Remove cored asbestos panel. Refer to Hazardous Materials specifications. Remove in full panels to provide opening required.26 Remove portion of concrete wall. Refer to Structural drawings for removal information. Coordinate with drawing D300 and Architecturals for dimensions. Sawcut

opening.29 Remove interior stair in its entirety, including but not limited to structural support framing, stringer, treads & risers, handrail/guardrail, finishes, fasteners.30 Remove lift in its entirety, including but not limited to lift body, power supply connection, foundation, framing, suspended pit assembly & finishes.34 Remove asbestos fin panel in its entirety, including but not limited to panel, fasteners, brackets, sealant. Refer to Hazardous Materials specifications.38 Remove metal siding, flashing, framing and sealants in locations indicated. Threaded rod fasteners to remain.48 Remove outside run handrails at Stairs A & B in their entirety, including but not limited to pipe, brackets, fasteners, sealant. Patch holes in walls where fasteners have

been removed. Interior run handrail to remain.56 Cut existing floor for 24" diameter chute installation. Refer to A417 for layout information.63 Remove Cementious Soffit Material and Related Framing.

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

1 2 3

5 6 7 8

A

C

B

Elevator 1 Elevator 2

Stair A

Stair BCorridor CorridorElevatorLobby

Balcony

1

1

4

9 4

19

14

1

TYPE 3 TYPE 1 TYPE 1 TYPE 2 TYPE 2 TYPE 3

TYPE 8 TYPE 7 TYPE 5 TYPE 4 TYPE 3

6 6

6

38

38 38 38 38 38

38

38 38

38 38 38

38

48

48 48

48

4

1

4

1

4

6

56

4

1 2 3

5 6 7 8

A

C

B

Elevator 1 Elevator 2

Stair A Stair BCorridor CorridorElevatorLobby

TYPE 3 TYPE 1 TYPE 1 TYPE 2 TYPE 2 TYPE 3

TYPE 8 TYPE 7 TYPE 2 TYPE 2 TYPE 3TYPE 2

4

1

1

9

41

1

47

6 6

38

38 38 38

38

38

38

38 38

38 38 38

38

48

48

48

48

4 4

1 1

1

6

4

56

4

63 AT 10th FLOOR ONLY

63 AT 8th FLOOR ONLY

GENERAL DEMOLITION NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCHALL LOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OFADJACENT FINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. ALL ITEMS SLATED FOR REMOVAL ARE SHOWN DASHED. DEMOLITIONKEYNOTE TAGS INDICATE TYPICAL REMOVALS.

4. REFER TO PHASING PLANS FOR PROJECT SEQUENCING.

5. ADDITIONAL DEMOLITION INFORMATION SPECIFIC TO TRADE ISIDENTIFIED WITHIN SITE, STRUCTURAL, MECHANICAL, PLUMBING,ELECTRICAL & FIRE PROTECTION DRAWINGS.

6. WORK AREAS & SPACES AVAILABLE TO TENANTS TO BE CLEANEDDAILY.

7. REFER TO A400 ENLARGED PLAN SERIES FOR DEMOLITION SPECIIFICTO EXISTING UNITS. UNIT TYPES 6, 9 & 10 ARE NEW & THE DEMO FORTHOSE INSTANCES IS ON D102.

8. EXISTING FLOORING IN ALL WORK AREAS TO BE REMOVED DOWN TOTHE CONCRETE DECK. REMOVALS TO INCLUDE BUT NOT LIMITED TO VINYLCOMPOSITION TILE, CARPET, SHEET FLOORING, CERMAIC TILE,TRANSITIONS, ADHESIVES & MASTICS, UNDERLAYMENT, MORTARBEDDING.

9. REFER TO D202 FOR ENLARGED DEMOLITION ELEVATIONS OF LOWERFLOORS

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

1/8" = 1'-0"

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:46

:18

PM

D103

Typical UpperFloorDemolitionPlans

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/8" = 1'-0"1TYPICAL UPPER FLOOR WITH BALCONY DEMOLITION PLAN

1/8" = 1'-0"2TYPICAL UPPER FLOOR WITHOUT BALCONY DEMOLITION PLAN

N

Demolition Keynotes

Key Key Note

1 Remove entire partition; including but not limited to gypsum board, studs, CMU, concrete, fasteners, finishes,building utilities within partition.

4 Remove door & frame in its entirety, including but not limited to door, frame, sidelight / glass, anchors, fasteners,finishes, hardware.

6 Remove all floor finishes in their entirety down to the original deck, including but not limited to cermaic tile, vinylcomposition tile, sheet flooring, mastic & adhesives, underlayment. Typical for Project in all areas.

9 Remove windows, storefront, curtainwall & louvers, including but not limited to window, louver, sub sill, blocking &shims, fasteners, sealant, backer rod & flashing. Typical at all instances.

19 Remove guardrail/handrail in its entirety, including but not limited to guardrail, handrails, fasteners, and precastconcrete panels at balconies.

38 Remove metal siding, flashing, framing and sealants in locations indicated. Threaded rod fasteners to remain.47 Remove utility sink in its entirety, including but not limited to sink body, support brackets, framing, fasteners, piping &

wall eschutcheon, sealant. Refer to Plumbing Drawings for additional information.48 Remove outside run handrails at Stairs A & B in their entirety, including but not limited to pipe, brackets, fasteners,

sealant. Patch holes in walls where fasteners have been removed. Interior run handrail to remain.56 Cut existing floor for 24" diameter chute installation. Refer to A417 for layout information.63 Remove Cementious Soffit Material and Related Framing.

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

UP

1 2 3 5 6 7 8

A

C

B

UP UP DNDN

Stair A

ST-A20

Stair B

ST-B20Elevator Lobby

2001

ELEVATORACCESS

2002

Elevator 2

E-02Elevator 1

E-01

4

44

19

9

4

4

3536 36

36

37

38

39

4040

40

40

40 40

40

39

41

4141

42

42

41

41

41

42

42

4343

43

38

38

38

43

6

48

48

Existing Roof ToRemain AsTemporaryProtection

4

22

22

22

22

1 2 3 5 6 7 8

A

C

B

37

3232

32

41

42

42

32

41

41

32

45

39

39

44

44

3232

323232

32

3232

42

39

39

40

35 3242

46

32 32

42

41

41

45

39

40

42

42

32

3232

32

38

38

38

38

3636

36

39

39

39

39

39 39

4

GENERAL DEMOLITION NOTES

1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCHALL LOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OFADJACENT FINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. ALL ITEMS SLATED FOR REMOVAL ARE SHOWN DASHED. DEMOLITIONKEYNOTE TAGS INDICATE TYPICAL REMOVALS.

4. REFER TO PHASING PLANS FOR PROJECT SEQUENCING.

5. ADDITIONAL DEMOLITION INFORMATION SPECIFIC TO TRADE ISIDENTIFIED WITHIN SITE, STRUCTURAL, MECHANICAL, PLUMBING,ELECTRICAL & FIRE PROTECTION DRAWINGS.

6. WORK AREAS & SPACES AVAILABLE TO TENANTS TO BE CLEANEDDAILY.

7. REFER TO A400 ENLARGED PLAN SERIES FOR DEMOLITION SPECIIFICTO EXISTING UNITS. UNIT TYPES 6, 9 & 10 ARE NEW & THE DEMO FORTHOSE INSTANCES IS ON D102.

8. EXISTING FLOORING IN ALL WORK AREAS TO BE REMOVED DOWN TOTHE CONCRETE DECK. REMOVALS TO INCLUDE BUT NOT LIMITED TO VINYLCOMPOSITION TILE, CARPET, SHEET FLOORING, CERMAIC TILE,TRANSITIONS, ADHESIVES & MASTICS, UNDERLAYMENT, MORTARBEDDING.

9. REFER TO D202 FOR ENLARGED DEMOLITION ELEVATIONS OF LOWERFLOORS

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

1/8" = 1'-0"

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:46

:31

PM

D104

Penthouse &Roof DemolitionPlans

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/8" = 1'-0"1PENTHOUSE DEMOLITION PLAN

1/8" = 1'-0"2ROOF DEMOLITION PLAN

N

Demolition Keynotes

Key Key Note

4 Remove door & frame in its entirety, including but not limited to door, frame, sidelight / glass, anchors, fasteners, finishes,hardware.

6 Remove all floor finishes in their entirety down to the original deck, including but not limited to cermaic tile, vinyl composition tile,sheet flooring, mastic & adhesives, underlayment. Typical for Project in all areas.

9 Remove windows, storefront, curtainwall & louvers, including but not limited to window, louver, sub sill, blocking & shims,fasteners, sealant, backer rod & flashing. Typical at all instances.

19 Remove guardrail/handrail in its entirety, including but not limited to guardrail, handrails, fasteners, and precast concrete panelsat balconies.

22 Remove cored asbestos panel. Refer to Hazardous Materials specifications. Remove in full panels to provide opening required.32 Remove mechanical unit & fence enclosure, including but not limited to equipment body, concrete pad, supply & waste lines &

connections.35 Existing caged ladder to remain; restore connections as required. Demolition36 Remove curb down to concrete deck, including but not limited to concrete, blocking, fasteners, flashing, waterproofing, roofing

material.37 Remove entirety of penthouse structure indicated down to concrete deck, including but not limited to framing, metal siding, roof

assembly, fasteners, flashing. Demolition38 Remove metal siding, flashing, framing and sealants in locations indicated. Threaded rod fasteners to remain.39 Remove entirety of roofing assembly down to concrete deck & concrete parapet wall, including but not limited to built up roofing,

ballast, flashing, parapet wall cap, roof accessories, term bars, fasteners, sealant. Area under proposed Penthouse to remain.Demolition

40 Remove rooftop mechanical units, including but not limited to equipment body, supply/waste lines & connections, curbs,blocking, fasteners, framing, sealant. Refer to Mechanical drawings for additional information on removals.

41 Remove roof drain, including but not limited to drain body, flashing, fasteners, sealant. Refer to Plumbing Drawings foradditional information.

42 Remove roof vent, including but not limited to vent body, piping, flashing, fasteners, sealant. Refer to Plumbing Drawings foradditional information.

43 Remove concrete sloped topping down to concrete deck.44 Remove skylight in its entirety, including but not limited to skylight, framing, fasteners, flashing, sealant, blocking.45 Remove smoke vent in its entirety, including but not limited to hatch body, framing, blocking, fasteners, sealant, flashing.46 Remove satellite dish in its entirety, including but not limited to dish, mounting bracket, framing, fasteners, sealant, exposed

calbing. Demolition48 Remove outside run handrails at Stairs A & B in their entirety, including but not limited to pipe, brackets, fasteners, sealant.

Patch holes in walls where fasteners have been removed. Interior run handrail to remain.

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

SITE-3' - 0"

1st FLOOR0"

2nd FLOOR13' - 6"

3rd FLOOR24' - 6"

4th FLOOR33' - 4"

5th FLOOR42' - 2"

6th FLOOR51' - 0"

7th FLOOR59' - 10"

8th FLOOR68' - 8"

9th FLOOR77' - 6"

10th FLOOR86' - 4"

11th FLOOR95' - 2"

12th FLOOR104' - 0"

13th FLOOR112' - 10"

14th FLOOR121' - 8"

15th FLOOR130' - 6"

16th FLOOR139' - 4"

17th FLOOR148' - 2"

18th FLOOR157' - 0"

19th FLOOR165' - 10"

T.O. EXIST PENTHOUSE183' - 4"

T.O. ELEVATOR HEADHOUSE200' - 8"

MACHINE ROOM192' - 0"

A CB

PENTHOUSE174' - 6"

9

9

42219

TYPICAL

35

38

9

4444

40

TYPICAL

40

3946

TYPICAL

D

1st FLOOR0"

1 2

3

5 6 7 8

2nd FLOOR13' - 6"

3rd FLOOR24' - 6"

4th FLOOR33' - 4"

5th FLOOR42' - 2"

6th FLOOR51' - 0"

7th FLOOR59' - 10"

8th FLOOR68' - 8"

9th FLOOR77' - 6"

10th FLOOR86' - 4"

11th FLOOR95' - 2"

12th FLOOR104' - 0"

13th FLOOR112' - 10"

14th FLOOR121' - 8"

15th FLOOR130' - 6"

16th FLOOR139' - 4"

17th FLOOR148' - 2"

18th FLOOR157' - 0"

19th FLOOR165' - 10"

T.O. EXIST PENTHOUSE183' - 4"

T.O. ELEVATOR HEADHOUSE200' - 8"

MACHINE ROOM192' - 0"

PENTHOUSE174' - 6"

38

9

39

39

44

46 40

TYPICAL

4239 37

39

42

9

TYPICAL

9

8

TYPICAL

TYPICAL

19

4

TYPICAL

TYPICAL

9

22

9

19

2219

22

9

9

492294 229

49944

19

TYPICAL

38TYPICAL

422

22

SEE PLAN, D101

GENERAL DEMOLITION NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCHALL LOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OFADJACENT FINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. ALL ITEMS SLATED FOR REMOVAL ARE SHOWN DASHED. DEMOLITIONKEYNOTE TAGS INDICATE TYPICAL REMOVALS.

4. REFER TO PHASING PLANS FOR PROJECT SEQUENCING.

5. ADDITIONAL DEMOLITION INFORMATION SPECIFIC TO TRADE ISIDENTIFIED WITHIN SITE, STRUCTURAL, MECHANICAL, PLUMBING,ELECTRICAL & FIRE PROTECTION DRAWINGS.

6. WORK AREAS & SPACES AVAILABLE TO TENANTS TO BE CLEANEDDAILY.

7. REFER TO A400 ENLARGED PLAN SERIES FOR DEMOLITION SPECIIFICTO EXISTING UNITS. UNIT TYPES 6, 9 & 10 ARE NEW & THE DEMO FORTHOSE INSTANCES IS ON D102.

8. EXISTING FLOORING IN ALL WORK AREAS TO BE REMOVED DOWN TOTHE CONCRETE DECK. REMOVALS TO INCLUDE BUT NOT LIMITED TO VINYLCOMPOSITION TILE, CARPET, SHEET FLOORING, CERMAIC TILE,TRANSITIONS, ADHESIVES & MASTICS, UNDERLAYMENT, MORTARBEDDING.

9. REFER TO D202 FOR ENLARGED DEMOLITION ELEVATIONS OF LOWERFLOORS

ELEVATION DEMOLITION LEGEND

CORED ASBESTOS PANELS TO BE REMOVED(NOTE 22)

TYPICAL MATERIAL ASSEMBLIES TO BE REMOVED(WINDOWS AT CONCRETE FINS, NOTE 8 & 9)

METAL PANEL TO BE REMOVED (NOTE 38)

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:47

:33

PM

D200

South & EastDemolitionElevations

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/16" = 1'-0"1SOUTH DEMOLITION ELEVATION

1/16" = 1'-0"2EAST DEMOLITION ELEVATION

Demolition Keynotes

Key Key Note

4 Remove door & frame in its entirety, including but not limited to door, frame, sidelight / glass, anchors, fasteners, finishes, hardware.8 Remove precast concrete fin wall; refer to unit demolition plan drawings for information.9 Remove windows, storefront, curtainwall & louvers, including but not limited to window, louver, sub sill, blocking & shims, fasteners, sealant, backer rod & flashing.

Typical at all instances.19 Remove guardrail/handrail in its entirety, including but not limited to guardrail, handrails, fasteners, and precast concrete panels at balconies.22 Remove cored asbestos panel. Refer to Hazardous Materials specifications. Remove in full panels to provide opening required.35 Existing caged ladder to remain; restore connections as required. Demolition37 Remove entirety of penthouse structure indicated down to concrete deck, including but not limited to framing, metal siding, roof assembly, fasteners, flashing. Demolition38 Remove metal siding, flashing, framing and sealants in locations indicated. Threaded rod fasteners to remain.39 Remove entirety of roofing assembly down to concrete deck & concrete parapet wall, including but not limited to built up roofing, ballast, flashing, parapet wall cap, roof

accessories, term bars, fasteners, sealant. Area under proposed Penthouse to remain. Demolition40 Remove rooftop mechanical units, including but not limited to equipment body, supply/waste lines & connections, curbs, blocking, fasteners, framing, sealant. Refer to

Mechanical drawings for additional information on removals.42 Remove roof vent, including but not limited to vent body, piping, flashing, fasteners, sealant. Refer to Plumbing Drawings for additional information.44 Remove skylight in its entirety, including but not limited to skylight, framing, fasteners, flashing, sealant, blocking.46 Remove satellite dish in its entirety, including but not limited to dish, mounting bracket, framing, fasteners, sealant, exposed calbing. Demolition

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

SITE-3' - 0"

1st FLOOR0"

2nd FLOOR13' - 6"

3rd FLOOR24' - 6"

4th FLOOR33' - 4"

5th FLOOR42' - 2"

6th FLOOR51' - 0"

7th FLOOR59' - 10"

8th FLOOR68' - 8"

9th FLOOR77' - 6"

10th FLOOR86' - 4"

11th FLOOR95' - 2"

12th FLOOR104' - 0"

13th FLOOR112' - 10"

14th FLOOR121' - 8"

15th FLOOR130' - 6"

16th FLOOR139' - 4"

17th FLOOR148' - 2"

18th FLOOR157' - 0"

19th FLOOR165' - 10"

T.O. EXIST PENTHOUSE183' - 4"

T.O. ELEVATOR HEADHOUSE200' - 8"

MACHINE ROOM192' - 0"

AC B

PENTHOUSE174' - 6"

35

38

39

TYPICAL

4444

40

TYPICAL

9

TYPICAL

39

949

16 31 31 31 31 32

D

22

BEYOND

GENERAL DEMOLITION NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCHALL LOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OFADJACENT FINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. ALL ITEMS SLATED FOR REMOVAL ARE SHOWN DASHED. DEMOLITIONKEYNOTE TAGS INDICATE TYPICAL REMOVALS.

4. REFER TO PHASING PLANS FOR PROJECT SEQUENCING.

5. ADDITIONAL DEMOLITION INFORMATION SPECIFIC TO TRADE ISIDENTIFIED WITHIN SITE, STRUCTURAL, MECHANICAL, PLUMBING,ELECTRICAL & FIRE PROTECTION DRAWINGS.

6. WORK AREAS & SPACES AVAILABLE TO TENANTS TO BE CLEANEDDAILY.

7. REFER TO A400 ENLARGED PLAN SERIES FOR DEMOLITION SPECIIFICTO EXISTING UNITS. UNIT TYPES 6, 9 & 10 ARE NEW & THE DEMO FORTHOSE INSTANCES IS ON D102.

8. EXISTING FLOORING IN ALL WORK AREAS TO BE REMOVED DOWN TOTHE CONCRETE DECK. REMOVALS TO INCLUDE BUT NOT LIMITED TO VINYLCOMPOSITION TILE, CARPET, SHEET FLOORING, CERMAIC TILE,TRANSITIONS, ADHESIVES & MASTICS, UNDERLAYMENT, MORTARBEDDING.

9. REFER TO D202 FOR ENLARGED DEMOLITION ELEVATIONS OF LOWERFLOORS

1st FLOOR0"

12

3

5678

2nd FLOOR13' - 6"

3rd FLOOR24' - 6"

4th FLOOR33' - 4"

5th FLOOR42' - 2"

6th FLOOR51' - 0"

7th FLOOR59' - 10"

8th FLOOR68' - 8"

9th FLOOR77' - 6"

10th FLOOR86' - 4"

11th FLOOR95' - 2"

12th FLOOR104' - 0"

13th FLOOR112' - 10"

14th FLOOR121' - 8"

15th FLOOR130' - 6"

16th FLOOR139' - 4"

17th FLOOR148' - 2"

18th FLOOR157' - 0"

19th FLOOR165' - 10"

T.O. EXIST PENTHOUSE183' - 4"

Basement-11' - 0"

T.O. ELEVATOR HEADHOUSE200' - 8"

MACHINE ROOM192' - 0"

PENTHOUSE174' - 6"

35

39

39

39

38

42

40

TYPICAL

TYPICAL37

39

42

9

8

TYPICAL

TYPICAL

19

22

922

9

22

9

38

TYPICAL

4

22

ELEVATION DEMOLITION LEGEND

CORED ASBESTOS PANELS TO BE REMOVED(NOTE 22)

TYPICAL MATERIAL ASSEMBLIES TO BE REMOVED(WINDOWS AT CONCRETE FINS, NOTE 8 & 9)

METAL PANEL TO BE REMOVED (NOTE 38)

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:48

:00

PM

D201

North & WestDemolitionElevations

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/16" = 1'-0"1NORTH DEMOLITION ELEVATION

1/16" = 1'-0"2WEST DEMOLITION ELEVATION

Demolition Keynotes

Key Key Note

4 Remove door & frame in its entirety, including but not limited to door, frame, sidelight / glass, anchors, fasteners, finishes, hardware.8 Remove precast concrete fin wall; refer to unit demolition plan drawings for information.9 Remove windows, storefront, curtainwall & louvers, including but not limited to window, louver, sub sill, blocking & shims, fasteners, sealant, backer rod & flashing.

Typical at all instances.16 Remove concrete site stair in its entirety, including but not limited to treads & risers, handrails, fasteners, coordinate limits with Structural Drawings.19 Remove guardrail/handrail in its entirety, including but not limited to guardrail, handrails, fasteners, and precast concrete panels at balconies.22 Remove cored asbestos panel. Refer to Hazardous Materials specifications. Remove in full panels to provide opening required.31 Remove bollard in it entirety, including but not limited to pipe & concrete infill, foundation.32 Remove mechanical unit & fence enclosure, including but not limited to equipment body, concrete pad, supply & waste lines & connections.35 Existing caged ladder to remain; restore connections as required. Demolition37 Remove entirety of penthouse structure indicated down to concrete deck, including but not limited to framing, metal siding, roof assembly, fasteners, flashing. Demolition38 Remove metal siding, flashing, framing and sealants in locations indicated. Threaded rod fasteners to remain.39 Remove entirety of roofing assembly down to concrete deck & concrete parapet wall, including but not limited to built up roofing, ballast, flashing, parapet wall cap, roof

accessories, term bars, fasteners, sealant. Area under proposed Penthouse to remain. Demolition40 Remove rooftop mechanical units, including but not limited to equipment body, supply/waste lines & connections, curbs, blocking, fasteners, framing, sealant. Refer to

Mechanical drawings for additional information on removals.42 Remove roof vent, including but not limited to vent body, piping, flashing, fasteners, sealant. Refer to Plumbing Drawings for additional information.44 Remove skylight in its entirety, including but not limited to skylight, framing, fasteners, flashing, sealant, blocking.

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

1 2 3 5 6 7 8

A

C

B

Elevator 1 Elevator 2

203

203

203

CustodialStorage

015

ElectricalSwitch

016Water Heater

017

ElectricalSwitchgear

006

CHA Storage

020Transformer

021

TelephoneService

018Pump

019

Stair A

ST-ABStair B

ST-BB

Maintenance

014

CompactorRoom

007

EquipmentStorage

004

Elevator Lobby

002Corridor003

Entry

001

Trash

005

DumpsterStorage

008

001

EEEE

007

005

E

003

ElectricalCloset

014A

ElectricalCloset

016AE

E

E

E

E

S1

E

E E

E

D8

203

007

1A210

2A210

S5

S5

D

007

Break Room

009002

007007007

007

007

002

004A

009

010

Toilet

010

4

Closet

012

LIMIT OF WORK

E

Access Drive

022

Elec Closet

022A

GENERAL NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALLLOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENTFINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. REFER TO A010 & A011 FOR PARTITION TYPES,TYPICAL PENETRATION &FIREPROOFING DETAILS.

4. REFER TO A600 FOR DOOR & FRAME SCHEDULE.

5. APARTMENT UNIT DOOR TAGS INDICATED ON ENLARGED UNIT PLANSA401 THROUGH A410

6. REFER TO A610 THROUGH A612 FOR WINDOW, CURTAINWALL &STOREFRONT INFORMATION.

7. REFER TO A700 FOR FINISH SCHEDULE & COORDINATE ASSEMBLYINSTALLATIONS AS REQUIRED FOR FINISHES.

8. REFER TO KEY LEGEND FOR ENLARGED PLANS OF 1ST & 2ND FLOORS

9. REFER TO PHASING PLANS FOR PROJECT SEQUENCING

10. REFER TO A450 FOR STAIR PLANS & DETAILS

A411

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:13

:50

PM

A100

Basement FloorPlan

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1 BASEMENT PLAN

N

1" = 30'-0"2BASEMENT ENLARGED PLAN KEY

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

UP

UP

1 2 3 5 6 7 8

A

C

B

SCES

108

Toilet

110

Refuse Closet

105

Entry Vestibule

101

CHA Office

122

CHA Office

123

Toilet

128

Closet

127A

Stair B

ST-B1Stair A

ST-A1

ConferenceRoom

124

Waiting /Lounge

118

Program Space1

119

Work Rm

126

Elevator Lobby

102

002

201

201 201

002

002004A 201004A

004A004A

007

004A 002

004A

002

002

007

004A

004A

007

202

202

004A

002

Mail

113

Women

114

Men

115

Program Space2

120

Elevator 1 Elevator 2

103B

103A

R1

105

R2

R1

122

S1

R1

127A

129

Service Coord

107Storage

109

Rear Vestibule

112

Multi-PurposeRoom

103

Corridor

106

Security

117

CHA Reception

121

Break Room

127

Fire CommandRoom

130

Corridor

104

109108

107

Corridor

116

Mop Closet

111A

111A

117

123

124

103

File Rm

125

002

002

005

007

002

007

007

002

002

007

007

002

121

002

007 007

004A

002

002

004A

007

007

002

S5

ACCESS CONTROLSYSTEM

010

007

S2 S2

111

OPP.HAND

TERRACOTTA ATINSIDE WALL OFVESTIBULE

002

002

007

002

001002

112A

104

007

004A

004A

004A004A 004A

002

002002

007

004A 004A

004A

004A

119 119A

120A

120

S1

004A

S6 S6

1A210

2A210

D

104A

007

1A351

2A351

1A352

2A352

L

C12

C15

C14

A9

A11

C10 C11 C10

C3

C3

C16A10T1

T1R

C4

C6C5

C4

A9 A9 A9

A9

S2S1

S4

S3

201004A

4

CommercialKitchen

111

004A

004A004A

004A

201

004A

SEE L401

SEE L406

007

007

SEE L402

C18

C19

A6123

A5532

A6122

201

007002

201

002

002

2A313

112

T2 4A553

?

GENERAL NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALLLOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENTFINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. REFER TO A010 & A011 FOR PARTITION TYPES,TYPICAL PENETRATION &FIREPROOFING DETAILS.

4. REFER TO A600 FOR DOOR & FRAME SCHEDULE.

5. APARTMENT UNIT DOOR TAGS INDICATED ON ENLARGED UNIT PLANSA401 THROUGH A410

6. REFER TO A610 THROUGH A612 FOR WINDOW, CURTAINWALL &STOREFRONT INFORMATION.

7. REFER TO A700 FOR FINISH SCHEDULE & COORDINATE ASSEMBLYINSTALLATIONS AS REQUIRED FOR FINISHES.

8. REFER TO KEY LEGEND FOR ENLARGED PLANS OF 1ST & 2ND FLOORS

9. REFER TO PHASING PLANS FOR PROJECT SEQUENCING

10. REFER TO A450 FOR STAIR PLANS & DETAILS

A412

A413

A414

1 2 3

103A

C5 C6D

E

D.3A525

1

1' - 1"

1' - 10"

1' -

0 5/

8"

R 14' - 10"

24' - 0"

22' -

4 3

/4"

8' -

3 1/

4"

2.72.3

D.7

SEE L406

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:14

:08

PM

A101

1st Floor Plan

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/8" = 1'-0"1FIRST FLOOR PLAN

N

3 FIRST FLOOR ENLARGED PLAN KEY 1/8" = 1'-0"2FIRST FLOOR PLAN ALTERNATE #1

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

W

D/D

D/D

D/D

WW

WW

D/D

D/D

D/D

1 2 3 5 6 7 8

A

C

B

1A313

TYPE 6(SIMILAR)

TYPE 6 TYPE 10A

TYPE 9 TYPE 6 TYPE 10

101

Tenant Council

211

ResidentLounge

203

Toilet

208

Refuse Closet

206

Stair A

ST-A2Stair B

ST-B2

Laundry

202

Elevator Lobby

201Corridor

212

004A

Utility

213

Elevator 1 Elevator 2

206

R1

205A

L2

T2

Storage

204A

Program Space3

204

Toilet

210

Storage

209

Deck

205

205

204A

R1

D8

203 L1

S11002

207B211

209

207A

S1

002

002

002

101

101

004A

004A

002

005

004A

002

002 007

002

007

004A

004A

201

201

007

007

004A

007

007

007

004A

004A

002

002

002

204

S1

Closet

207A

Storage

207B

002002

S4 S4

1A210

2A210

3A512

D

C13

C8 C9 C2

U6

S9

4

OVERHANG ABOVE

ENTRANCE CANOPYSEE A107

SEE A106 FORROOF PLAN

007 007

2A351

RD RD

UP

DN

UP

DN

Corridor

207

007

202

201

201

102102

102

201

201102

102

102

2A313

1 2 3

C

Roof GardenDeck

205

Program Space3

204

D

E

D.3

OVERHANG ABOVE

TRELLIS ABOVEPLANTER

1A527

2A527

DASHED LINE:RAMP BELOW7'-

9 1/

4"14

'-7 1

/2"

8'-3

1/4"

5A527

C4

C7

C9

4

A204

3

RD

RD RD

GLASS CANOPYSEE A107

ENTRANCE CANOPYBASE BID

3A316

4A316

2.72.3

D.7

2A313

7'-9 1/2" 8'-10 1/2" 7'-4"

GENERAL NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALLLOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENTFINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. REFER TO A010 & A011 FOR PARTITION TYPES,TYPICAL PENETRATION &FIREPROOFING DETAILS.

4. REFER TO A600 FOR DOOR & FRAME SCHEDULE.

5. APARTMENT UNIT DOOR TAGS INDICATED ON ENLARGED UNIT PLANSA401 THROUGH A410

6. REFER TO A610 THROUGH A612 FOR WINDOW, CURTAINWALL &STOREFRONT INFORMATION.

7. REFER TO A700 FOR FINISH SCHEDULE & COORDINATE ASSEMBLYINSTALLATIONS AS REQUIRED FOR FINISHES.

8. REFER TO KEY LEGEND FOR ENLARGED PLANS OF 1ST & 2ND FLOORS

9. REFER TO PHASING PLANS FOR PROJECT SEQUENCING

10. REFER TO A450 FOR STAIR PLANS & DETAILS

A417

A409 A406

A406 A406

A410

A410

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:14

:20

PM

A102

2nd Floor Plan

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/8" = 1'-0"1SECOND FLOOR PLAN

N

1/8" = 1'-0"2SECOND FLOOR PLAN / ALTERNATE #1 3 SECOND FLOOR ENLARGED PLAN KEY

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

1 2 3 5 6 7 8

A

C

B

TYPE 3 TYPE 1 TYPE 1 TYPE 2 TYPE 2 TYPE 3

TYPE 8 TYPE 7 TYPE 2 TYPE 2 TYPE 3TYPE 2

Elevator 1 Elevator 2

Elevator Lobby

401

Corridor

402

Corridor

404

Stair A

ST-A4

Refuse Closet

403 Stair BST-B4

24' - 0" 24' - 0"

22' -

10"

22' -

10"

Utility

405

1A313

Open To Below

EmergencyElectrical Closet

@ 6th & 14thFloors Only

201

201

201

201

A5001

A5001 Opp. Hd.

A5003 Opp. Hd.A500

11

A5008

A5008

C1

S1

S1L1 L1

1A210

2A210

T2

005

T1

201

U6

S6

4

005

201

201

007

201

2A313

24' - 0" 24' - 0" 24' - 0"16' - 0" 24' - 0"

1 2 3 5 6 7 8

TYPE 3

A

C

B

TYPE 1 TYPE 1 TYPE 2 TYPE 2 TYPE 3

TYPE 8 TYPE 7

TYPE 5 TYPE 4

TYPE 3

Elevator 1 Elevator 2

Elevator Lobby

301Corridor302

Corridor

304

Stair A

ST-A3 Stair BST-B3

Refuse Closet

303

22' -

10"

22' -

10"

24' - 0" 24' - 0"

Utility

305

201

201

201

201S1

S1

L2

L1L1

1A210

2A210

T2007

005

T1

U6

S8

C1

4

201

005 201

201

Lounge

306

24' - 0" 24' - 0" 24' - 0"16' - 0" 24' - 0"

UNIT TYPE ENLARGED PLANS LEGEND

-UNIT TYPE 1: A401-UNIT TYPE 2 & 2A: A402-UNIT TYPE 3 & 3A: A403-UNIT TYPE 4: A404-UNIT TYPE 5: A405-UNIT TYPE 6: A406-UNIT TYPE 7: A407-UNIT TYPE 8: A408-UNIT TYPE 9: A409-UNIT TYPE 10 & 10A: A410

GENERAL NOTES

1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALLLOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENTFINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. REFER TO A010 & A011 FOR PARTITION TYPES,TYPICAL PENETRATION &FIREPROOFING DETAILS.

4. REFER TO A600 FOR DOOR & FRAME SCHEDULE.

5. APARTMENT UNIT DOOR TAGS INDICATED ON ENLARGED UNIT PLANSA401 THROUGH A410

6. REFER TO A610 THROUGH A612 FOR WINDOW, CURTAINWALL &STOREFRONT INFORMATION.

7. REFER TO A700 FOR FINISH SCHEDULE & COORDINATE ASSEMBLYINSTALLATIONS AS REQUIRED FOR FINISHES.

8. REFER TO KEY LEGEND FOR ENLARGED PLANS OF 1ST & 2ND FLOORS

9. REFER TO PHASING PLANS FOR PROJECT SEQUENCING

10. REFER TO A450 FOR STAIR PLANS & DETAILS

A422 A422A421

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:14

:37

PM

A103

3rd Through 7thFloor Plans

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

2 4TH, 5TH & 6TH FLOORS PLAN - (See A421 for 5th Floor Balcony)

1 3RD & 7TH FLOORS PLAN

N

1" = 30'-0"33RD THROUGH 7TH FLOORS ENLARGED PLAN KEY

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

WW

D/D

D/D

DW

1 2 3 5 6 7 8

A

C

B

TYPE 3 TYPE 1 TYPE 1 TYPE 2 TYPE 2 TYPE 3

TYPE 3A TYPE 2 TYPE 2 TYPE 2 TYPE 3TYPE 2

Corridor

804Stair B

ST-B8

Stair A

ST-A8Corridor

802

Refuse Closet

803

Elevator 1 Elevator 2

24' - 0" 24' - 0" 40' - 0" 24' - 0" 24' - 0" 24' - 0"

22' -

10"

22' -

10"

Utility

805

Open To Below

T2

201

201

201

201S1

S1L1 L1

Elevator Lobby

801

1A210

2A210

005

T1

U6

S5

C1

4

201

007005

201

201005

201

1 2 3 5 6 7 8

A

C

B

TYPE 3 TYPE 1 TYPE 1 TYPE 2 TYPE 2 TYPE 3

TYPE 3 TYPE 2 TYPE 2 TYPE 2 TYPE 3TYPE 2

TYPE 2A AT10TH TO 19TH FLOORS

Elevator 1 Elevator 2

Stair A

ST-A9

Corridor

902Elevator Lobby

901Corridor

904Stair B

ST-B9

Refuse Closet

903

24' - 0" 24' - 0" 40' - 0" 24' - 0" 24' - 0" 24' - 0"

22' -

10"

22' -

10"

Utility

905

T2201

201

201

201

A5008

A5001

A5003 Opp. Hd.A500

11

A5001

A5008

S1

L2

S1L1 L1

1A210

2A210

005

007

T1

U6

S7

C1

4

201

201

005

GENERAL NOTES

1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALLLOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENTFINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. REFER TO A010 & A011 FOR PARTITION TYPES,TYPICAL PENETRATION &FIREPROOFING DETAILS.

4. REFER TO A600 FOR DOOR & FRAME SCHEDULE.

5. APARTMENT UNIT DOOR TAGS INDICATED ON ENLARGED UNIT PLANSA401 THROUGH A410

6. REFER TO A610 THROUGH A612 FOR WINDOW, CURTAINWALL &STOREFRONT INFORMATION.

7. REFER TO A700 FOR FINISH SCHEDULE & COORDINATE ASSEMBLYINSTALLATIONS AS REQUIRED FOR FINISHES.

8. REFER TO KEY LEGEND FOR ENLARGED PLANS OF 1ST & 2ND FLOORS

9. REFER TO PHASING PLANS FOR PROJECT SEQUENCING

10. REFER TO A450 FOR STAIR PLANS & DETAILS

UNIT TYPE ENLARGED PLANS LEGEND

-UNIT TYPE 1: A401-UNIT TYPE 2 & 2A: A402-UNIT TYPE 3 & 3A: A403-UNIT TYPE 4: A404-UNIT TYPE 5: A405-UNIT TYPE 6: A406-UNIT TYPE 7: A407-UNIT TYPE 8: A408-UNIT TYPE 9: A409-UNIT TYPE 10 & 10A: A410

A422 A422A420

A422 A422A421

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:15

:00

PM

A104

8th, 9th, 13th &17th Floor Plans

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1 8TH FLOOR PLAN

2 9TH, 13TH & 17TH FLOORS PLAN

N

1" = 30'-0"49TH, 13TH & 17TH FLOORS ENLARGED PLAN KEY

1" = 30'-0"38TH FLOOR ENLARGED PLAN KEY

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

1 2 3 5 6 7 8

A

C

B

TYPE 3 TYPE 1 TYPE 1 TYPE 2 TYPE 3

TYPE 3 TYPE 2 TYPE 5 TYPE 4 TYPE 3

TYPE 2A

Elevator 1 Elevator 2

Stair B

ST-B11

Corridor

1104

Elevator Lobby

1101

Refuse Closet

1103

Corridor

1102Stair A

ST-A11

24' - 0" 24' - 0" 40' - 0" 24' - 0" 24' - 0" 24' - 0"

22' -

10"

22' -

10"

Utility

1105

T2

SEE SHEETA421 FORROOM LAYOUT

201

201 201

201

A5008

A5001

A5003 Opp. Hd.

A50011

A5001

A5008

S1

S1L1 L1

1A210

2A210

T1

A50010

A5003

U6

9"

S8

C1

4

L2

201

201

005

007

005201

201

1 2 3 5 6 7 8

A

C

B

TYPE 3 TYPE 1 TYPE 1 TYPE 2 TYPE 3

TYPE 3 TYPE 2 TYPE 2 TYPE 2 TYPE 3TYPE 2

TYPE 2A

Elevator 1 Elevator 2

Stair B

ST-B10

Corridor

1004

Elevator Lobby

1001Corridor

1002

Stair A

ST-A10

24' - 0" 24' - 0" 40' - 0" 24' - 0" 24' - 0" 24' - 0"

22' -

10"

22' -

10"

Refuse Closet

1003

Utility

1005

T2201

201

201

201S1

S1L1 L1

1A210

2A210

201

005

007

T1

U6

S5

C1

4

EmergencyElectrical Closet

@ 6th & 14thFloors Only

201

201

005

201

GENERAL NOTES

1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALLLOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENTFINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. REFER TO A010 & A011 FOR PARTITION TYPES,TYPICAL PENETRATION &FIREPROOFING DETAILS.

4. REFER TO A600 FOR DOOR & FRAME SCHEDULE.

5. APARTMENT UNIT DOOR TAGS INDICATED ON ENLARGED UNIT PLANSA401 THROUGH A410

6. REFER TO A610 THROUGH A612 FOR WINDOW, CURTAINWALL &STOREFRONT INFORMATION.

7. REFER TO A700 FOR FINISH SCHEDULE & COORDINATE ASSEMBLYINSTALLATIONS AS REQUIRED FOR FINISHES.

8. REFER TO KEY LEGEND FOR ENLARGED PLANS OF 1ST & 2ND FLOORS

9. REFER TO PHASING PLANS FOR PROJECT SEQUENCING

10. REFER TO A450 FOR STAIR PLANS & DETAILS

UNIT TYPE ENLARGED PLANS LEGEND

-UNIT TYPE 1: A401-UNIT TYPE 2 & 2A: A402-UNIT TYPE 3 & 3A: A403-UNIT TYPE 4: A404-UNIT TYPE 5: A405-UNIT TYPE 6: A406-UNIT TYPE 7: A407-UNIT TYPE 8: A408-UNIT TYPE 9: A409-UNIT TYPE 10 & 10A: A410

A422 A422A420

A422 A422A421

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:15

:24

PM

A105

10th, 11th, 12th,14th, 15th, 16th,18th, & 19thFloors Plan

ASH

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

ASH

2 11TH, 15TH & 19TH FLOORS PLAN

1 10TH, 12TH, 14TH, 16TH & 18TH FLOORS PLAN

N

1" = 30'-0"310TH, 12TH, 14TH, 16TH & 18TH FLOORS ENLARGED KEY PLAN

1" = 30'-0"411TH, 15TH & 19TH FLOORS ENLARGED KEY PLAN

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

UP

UP

UP

UP

UP

UP

UP

UP

UP

FD FD

1 2 3 5 6 7 8

A

C

B

4.4 5.2

A.4

A.8

B.2

B.9

24' - 0" 24' - 0" 25' - 10" 14' - 2" 6' - 10" 17' - 2" 24' - 0" 24' - 0"

2' -

8"10

' - 4

"9'

- 10

"6'

- 6"

9' -

4"7'

- 0"

1A321

ERV 2

ERV 1

MODIFIED BITUMINOUS ROOF OVER4 1/2" RIGID INSULATION OVERMETAL DECK ON NEWSTRUCTURAL FRAMING (NEW)

CHILLER 2CHILLER 1

1A322

2A322

17' -

4"

2' -

5 1/

2"

1' - 0"7' - 7 1/2" 24' - 3"

ROOF SCREEN

ROOF SCREEN

MIN 3'-0"

DN DN

RDOD

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

DN

RD

RD

RD

RD

RV

RV

RV

EXISTING SCUPPERAND DOWNSPOUT

----

DN

DNRD

8" 8"

8"12

' - 0

"3'

- 8"

MIN

3'-0

"

MIN

3'-0

"7' - 0" 6' - 7 1/2" 3' - 8 1/2"

EXISTING CAGED LADDER

EXISTING REFUSE CHUTE VENT

4"

6' - 2"

MIN

3'-0

"

ROOF SCREEN

DN

DN

DN

DN

DN

DN

RD

DN

DN

DN

DN

RD

EXISTING SCUPPER EXISTING SCUPPER

RV

EXHAUST FANSEE HVAC DRAWINGS

+/- 9

1/2

"

+/- 1' - 5 1/2"

+/- 1

' - 1

0 1/

2"

+/- 1' - 5 1/2"

+/- 1

' - 1

0 1/

2"

+/- 1

' - 1

0 1/

2"

DN DN

DN DN

2' - 10" 2' - 0"

+/- 5

' - 1

1 1/

2"+/

- 5' -

11

1/2"

+/- 1' - 5 1/2"

1A210

2A210

4

MODIFIED BITUMINOUS ROOFOVER TAPERED INSULATIONOVER EXISTING STRUCTURE

MODIFIED BITUMINOUS ROOFOVER TAPERED INSULATIONOVER EXISTING STRUCTURE,MINIMUN 4 1/2", TYPICAL

EXHAUST STACK,SEE MECH DWGS

1 2 3 5 6 7 8

A

C

B

1A320

4.4 5.2

UPDN UP DN

ERV 1

ERV 2

AIR-COOLEDCHILLER

Stair A

ST-A20

Stair B

ST-B20Elevator Lobby

2001

Elevator 2Elevator 1ELEVATOR

ACCESS

2002

MechanicalRoom

2003

UP

A.4

A.8

B.2

B.9

24' - 0" 24' - 0" 25' - 10" 14' - 2" 6' - 10" 17' - 2" 24' - 0" 24' - 0"

2' -

8"10

' - 4

"9'

- 10

"6'

- 6"

9' -

4"7'

- 0"

E

U2

U3

5A321

7A321

3A321

2A321

1A321

4A321

2A320

A5304

A5303

A53012

6A321

5A322

1A501

1A322

A5308

3A322

2A322

4A533

5A532

AIR-COOLEDCHILLER

MIN

3'-0

"

4A322

RD

RV

POST FOR ROOF SCREEN, TYP

MIN

3'-0

"

3' -

0"RV

+/- 207' - 6 3/4"

RD

RD

RD

RV

RV

RD

RV

RD

+/- 203' - 7 1/2"

----

PAINTED STEEL LADDERSEE 9/A523

A5336

A5336

4"

3' -

8"12

' - 0

"8"

6' -

5 1/

2"1'

- 0"

5A533

----

A53010

8" 8"

LOUVERSEE HVAC DRAWINGS

RD

RD

OPEN TO BELOW

TYP

8' - 0"

1' - 0"

1' -

0"

1' -

0"7' -

8"

4' -

2"

2' - 2"

2' - 2"A530

5

5A532

CONCRETE HOUSEKEEPING PADSEE HVAC AND STRUCTURAL DRAWINGS

S3U4 S3

1A210

2A210

A5337

A5338

C1

4

202

201

MODIFIED BITUMINOUS ROOF OVERTAPERED INSULATION OVER EXISTINGSTRUCTURE, MINIMUN 4 1/2", TYPICAL

MODIFIED BITUMINOUS ROOF OVERTAPERED INSULATION OVER EXISTINGSTRUCTURE, MINIMUN 4 1/2", TYPICAL

201

201

201

101

GENERAL NOTES1. WHERE EXISTING FINISH SURFACE IS TO REMAIN, REPAIR & PATCH ALLLOCATIONS ASSOCIATED WITH DEMOLITION & REMOVAL OF ADJACENTFINISHES, FRAMING, FASTENERS, ETC...

2. PROTECT ALL MATERIALS, DOORS/FRAMES, FINISHES THAT ARE TOREMAIN AT COMPLETION.

3. REFER TO A010 & A011 FOR PARTITION TYPES,TYPICAL PENETRATION &FIREPROOFING DETAILS.

4. REFER TO A600 FOR DOOR & FRAME SCHEDULE.

5. APARTMENT UNIT DOOR TAGS INDICATED ON ENLARGED UNIT PLANSA401 THROUGH A410

6. REFER TO A610 THROUGH A612 FOR WINDOW, CURTAINWALL &STOREFRONT INFORMATION.

7. REFER TO A700 FOR FINISH SCHEDULE & COORDINATE ASSEMBLYINSTALLATIONS AS REQUIRED FOR FINISHES.

8. REFER TO KEY LEGEND FOR ENLARGED PLANS OF 1ST & 2ND FLOORS

9. REFER TO PHASING PLANS FOR PROJECT SEQUENCING

10. REFER TO A450 FOR STAIR PLANS & DETAILS

2 3

A

DN

DN

DN

DNRD DN

DN

DN

DNRD

4MODIFIED BITUMINOUS ROOF OVER4 1/2" RIGID INSULATION OVERMETAL DECK ON NEWSTRUCTURAL FRAMING (NEW)

1 2 3

C

DN

DN

DN

RD

MODIFIED BITUMINOUS ROOF OVERTAPERED INSULATION OVER EXISTINGSTRUCTURE, MINIMUN 4 1/2", TYPICAL

1 2

DN

DN

DN

DN

RD

DN

DN

DN

DN

RD

D

MODIFIED BITUMINOUSROOF OVER 4 1/2" RIGIDINSULATION OVER METALDECK ON NEW STRUCTURALFRAMING (NEW)

ROOF NOTES

-COORD W/ MEP DRAWINGS

-REFER TO MUNUFACTURER DETAILS

-ALL ROOF SLOPES TO BE 1/4" PER 1'-0" UNLESS OTHERWISE NOTED

-ALL ROOF TO BE TYPE A UNLESS OTHERWISE NOTEDTYPE A: COLD APPLIED SBS MODIFIED BITUMINOUS MEMBRANE

W/ FLUID APPLIED ENERGY STAR EMULSION TOP COATTYPE B: IDENTICAL TO TYPE A BUT TOP COAT IS PVC ALLOY SINGLE-PLY

-ROOFING ASSEMBLY BASIS OF DESIGN: TREMCO ROOFING

-MIN 4 1/2" OF INSULATION TO BE PROVIDED AT ALL ROOFS (R-25)

ROOF LEGEND

- RD: ROOF DRAIN / OD: OVER FLOW DRAIN

- RV: ROOF VENT

- SCUP: SCUPPER

- DS: DOWNSPOUT

3

C

B

4.4

A.4

A.8

B.2

B.9

HATCHED AREA: FLOOR INFILLSEE STRUCTURAL DRAWINGS

LADDERSEE 9/A533

HOT WATER STORAGE TANKSEE MECAHNICAL DRAWINGS

+/- 9' - 0" 25' - 10"

1' -

0"9'

- 4"

6' -

6"9'

- 10

"10

' - 4

"

EXISTING ELEVATOR HOISTWAY

EXISTING CAGED LADDER

A5306

+/- 5

' - 3

"+/

- 4"

EXISTING LOUVERV.I.F.

4

DN

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

1/8" = 1'-0"

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:15

:53

PM

A106

Penthouse &Roof Plans

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/8" = 1'-0"3ROOF PLAN

1/8" = 1'-0"1PENTHOUSE PLAN

N

1/8" = 1'-0"5COMMERCIAL KITCHEN ROOF PLAN

1/8" = 1'-0"78TH FLOOR ROOF PLAN

1/8" = 1'-0"63RD FLOOR ROOF PLAN - ALTERNATE #1

1/8" = 1'-0"2MECHANICAL PENTHOUSE, UPPER FLOOR

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

3 5 6 7 8

C

3A512

3A502

3A311

DS, DOWNSPOUT @CONOPY GUTTER, TYP

DS DS DSDS @ UPPERCANOPY

DASHED LINES:ALTERNATE #1

3A107

4A107

4

A1075

+/- 2' - 10"

(4) EQ

16' - 0" 6"

(24) EQ

96' - 0" 6' - 5 7/8"

5' -

7"

7' -

4 1/

2"

(2) E

Q

8' -

0"1'

- 9

3/4"4' - 0 1/4"

1A352

2A352

6' -

2 1/

2"

5' -

6 1/

2"8"

4' -

6 1/

8"

1' -

11 1

/4"

9' -

0 1/

8"

1' -

6 1/

8"7'

- 9

1/4"

1' -

0 1/

8"6'

- 6

1/4"

5' -

3 1/

4"6

1/8"

4' -

0 3/

8"

12' -

10

3/4"

2

3

C

3A527

2A316

D

D.3

1A527

2A527

CANOPY GLASS EDGES ARE FACETEDWITH CORNERS MEETING THE RADIUSAS SHOWN

6 EQ. SPACES= ARC LENGTH OF30'-4 1/4"; (75 deg.)

5A5276"

6"INNER EDGE OF CANOPY

R 17' - 4"

OUTTER EDGE OF CANOPY

R 22' - 9 1/2"

(6) E

Q75.00

PROVIDE HOLES AT GLAZINGFOR FRAMING FASTENER @BOTH END OF CANOPY

PROVIDE HOLES AT GLAZINGFOR FRAMING FASTENER @BOTH END OF CANOPY

DOWNSPOUT @ CANOPY GUTTERCONNECTO TO STORM SYSTEM

DOWNSPOUT @CANOPY GUTTERCONNECTO TOSTORM SYSTEM

DASHED LINES: BASE BID

4A527

1' -

0 5/

8"

1' - 10"

FACE O

F METAL PAN

ELR

17' - 6 1/2"FACE OF M

ETAL PANEL

R 17' - 3 1/2"

9 1/

4"

(5) E

Q

20' -

0"

6"

3' - 0"

5' - 6"

2.72.3

D.7

CAP WITH CONCEALEDFASTENER

GLAZING

STRUCTURAL CANOPY SUPPORTSEE STRUCTURAL DRAWINGS

CAP WITH CONCEALEDFASTENER

GLAZINGPROVIDE HOLES FORFASTENER

STRUCTURAL CANOPY SUPPORTSEE STRUCTURAL DRAWINGS

PROVIDE END CAPSON BOTH END

PROVIDE END CAPSON BOTH END

INTERMEDIATEEDGE

STRUCTURAL CANOPY SUPPORTSEE STRUCTURAL DRAWINGS

AT TIE ROD

STEEL PLATE FOR TIE RODSEE STRUCTURAL DRAWINGS

TIE RODSEE STRUCTURAL DRAWINGS

FILLER

GLAZING

GLAZING FRAME BEYOND

5

C

DASHED LINES:STRUCUTRAL CANOPY SUPPORT@ UNDERSIDE OF GLAZINGSEE STRUCTURAL DRAWINGS

EXISTING CONRETE PIER

METAL EXTRUSION

STEEL PLATESEE STRUCTURAL DRAWINGS

DOWNSPOUT

GLASS CANOPY

GLASS CANOPY FRAMING

METAL GUTTER

CONTINUOUS BUTYL SEALANT

INSULATED METAL PANEL

COMPRESSIBLE FILLER

7 1/

2"

CORNER TRIM W/ CONTINUOUSBUTYL SEALANT

ARCHITECT

PROJECT NAME

CLIENT

PROJECT TEAM

REVISIONS

DRAWING TITLE

DRAWING INFORMATION

DRAWING NUMBER

Bargmann Hendrie + Archetype, Inc.300 A StreetBoston, MA 02210617 350-0450 Tel617 350-0215 Faxwww.bhplus.com

Copyright BH+A, Inc.

DATE OF ISSUE

DESCRIPTION

SCALE DRAWN BY

PROJECT # FILE NAME

12345

DATE

+abh

Manning Apts.rvt

STRUCTURAL CONSULTANTDM Berg Consultants, PC100 Crescent Road, Suite 1ANeedham, MA 02494718-444-5156 Tel718-444-5157 Faxwww.dmberg.com

MECHANICAL, PLUMBING, &FIRE PROTECTION CONSULTANTVAV International, Inc.400 W. Cummings Park, Suite 4700Woburn, MA 01801781-935-7228 Tel781-935-1822 Faxwww.vavint.com

ELECTRICAL CONSULTANTNangle Engineering Incorporated32 Prince StreetDanvers, MA 01923978-777-7650 Tel978-777-7653 Faxwww.nangleengineering.com

LANDSCAPE ARCHITECTHammer+Walsh Design Inc.300 A StreetBoston, MA 02210-1620617-439-0125 Tel617-439-0126 Fax

CIVIL CONSULTANTDesign Consultants, Inc. (DCI)120 Middlesex Avenue, Suite 20Somerville, MA 02145617-776-3350 Tel617-776-7710 Fax

362 Green StreetCambridge, MA 02139617-864-3020 Tel616-868-5372 Faxwww.cambridge-housing.org

NOT FOR CONSTRUCTION

100% PROGRESS

As indicated

D:\R

evit\

Man

ning

Apa

rtmen

ts -

r201

4_ah

onsa

ker.r

vt10

/9/2

015

3:16

:24

PM

A107

Glass CanopyPlan

Author

2896

September 11, 2015

99% CD Submission

Frank J.ManningApartments237 Franklin Street, Cambridge,MA 02139

CambridgeHousingAuthority

Auth

or

1/4" = 1'-0"1GLASS CANOPY PLAN

1/4" = 1'-0"2GLASS CANOPY PLAN @ TERRACE / ALTERNATE #1

1 1/2" = 1'-0"3TYPICAL CANOPY DETAIL

1 1/2" = 1'-0"4CANOPY DETAIL @ TIE ROD

1 1/2" = 1'-0"5TYPICAL PLAN DETAIL @ CANOPY SUPPORT

ISSUED FOR:

SPECIALPERMITAPPLICATION

OCTOBER 14, 2015

SPECIAL PERMIT APPLICATION

L

SITE-3' - 0"

1st FLOOR0"

1 2 3 5 6 7 8

2nd FLOOR13' - 6"

3rd FLOOR24' - 6"

4th FLOOR33' - 4"

5th FLOOR42' - 2"

6th FLOOR51' - 0"

7th FLOOR59' - 10"

8th FLOOR68' - 8"

9th FLOOR77' - 6"

10th FLOOR86' - 4"

11th FLOOR95' - 2"

12th FLOOR104' - 0"

13th FLOOR112' - 10"

14th FLOOR121' - 8"

15th FLOOR130' - 6"

16th FLOOR139' - 4"

17th FLOOR148' - 2"

18th FLOOR157' - 0"

19th FLOOR165' - 10"

T.O. EXIST PENTHOUSE183' - 4"

T.O. NEW PENTHOUSE190' - 9"

T.O. ELEVATOR HEADHOUSE200' - 8"

A3011

A3021

A3031

A3061

A3071

A3102

A2031

PENTHOUSE174' - 6"

4.4 5.2

MECHANICAL ROOM177' - 10"

A3051

23' -

4"

26' -

6"

8' -

10"

26' -

6"

8' -

10"

26' -

6"

8' -

10"

26' -

6"

13' -

1 1

/2"

A2051

A B A B AC X

3" INSULATED METAL PANELASSEMBLY WITH PREFABRICATEDTRIMLESS BENT CORNERS

TERRACOTTAASSEMBLY TC1

C8

A1 A2 A2

A4 A4 A4

A5

C1

C2

T1

C1

C1

C1

C1

C1

C1

C1

C1

B5 B5

C5 C6

C9

C16 C3 C3

B5 B5-b

A2A1

A1

A1

A1

A1

A1

A2 A2

A1 A1

A2 A2 A2

A2 A2 A2

A2 A2 A2

A2 A2 A2A2

A2

A2

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1 A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

B1 B2

B1 B2

B1 B2

B1 B2

B1 B2

B7 B8

B1 B3

B3 B1B2

B2B2

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B3 B1

B2

B2B2

B2B2

B2

B2B2

B2B2

B2B2

B2

B2B2

B2B2

B2B2

B2

B2B2

B2B2

B2B2

B1 B3

B1 B3

B1 B3

B1 B3

B1 B3

B1 B3

B1 B3

B1 B3

B1 B3

B1 B3

METAL PANEL WIDTHS. SEEKEY. ENTIRE SCHEDULE OFINSULATED METAL WALLPANELS WILL BE INCLUDEDIN FINAL CONSTRUCTIONDOCUMENTS INDICATING ALLSIZES, COLORS, & FINISHESOF EACH PANEL

A10

D

E F A B CY Y B B BA A AX X E B BY Y E Y YB B

D D D D D D D D D

H CABB AAX

A B A B AC X H F

D D D G D D D D D D D

Y A B C C A B A W F E F Y YA A AB B F H CABB AAX

METAL PANEL WIDTHS. SEEKEY.

4

L7