implant solutions flier

12
© MIS Corporation. All Rights Reserved. ® IMPLANT SOLUTIONS ®

Upload: mis-implants-technologies

Post on 12-Mar-2016

231 views

Category:

Documents


1 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Implant Solutions Flier

© MIS Corporation. All Rights Reserved.

®

IMPLANT SOLUTIONS

®

Page 2: Implant Solutions Flier
Page 3: Implant Solutions Flier
Page 4: Implant Solutions Flier

8mm, 10mm, 11.5mm, 13mm, 16mmØ3.75

8mm, 10mm, 11.5mm, 13mm, 16mmØ4.20

8mm, 10mm, 11.5mm, 13mm, 16mmØ5

10mm, 11.5mm, 13mm, 16mmØ3.30

C1 implant dimensions

The C1 implant system is an advanced implant design that offers a unique combination of surgical and restorative benefits, including a differential thread design to ensure superior initial stability in different clinical situations, platform switching and a conical connection with an anti-rotation index. Each C1 implant comes with a single-use final drill to ensure a safer and more accurate drilling procedure.

Conical Connection

Page 5: Implant Solutions Flier

Platform switchingThe C1 features platform switching, that keeps the implant-abutment connection away from the bone; minimizing bone resorption. Platform-switching additionally allows more vital growth of the soft tissue.

C1 implantThe C1 features a 6-degree conical connection ensures a secure fit between the abutment and implant. By minimizing micro-movement at that junction bone loss at the crestal level is reduced. There is a six-position cone index within the conical connection to help orient the implant during insertion as well as placing the abutment into the proper position.

Micro ringsAt the neck of the C1, micro-rings significantly increase the BIC (Bone to Implant Contact), avoiding bone resorption at the crestal zone.

Dual threadThe C1 features a dual thread design which increases the BIC (Bone to Implant Contact) over the entire body of the implant. The dual thread doubles implant insertion rate (1.50mm), facilitating a simpler and faster implant placement.

Surface treatmentC1 implants are sand-blasted and acid-etched. These surface treatments increase the implant surface area by creating both micro and nano-structures and eliminating various surface contaminants.

Conical shapeWith its conical, root-shaped geometry and a unique thread design, C1 ensures a superior primary stability and offers the ultimate choice for a wide range of clinical cases and loading protocols. Its root-shaped design makes C1 ideal for narrow spaces, restricted by adjacent teeth or implants.

Two spiral channels & domed apexThe C1 features a domed apex, providing a high tolerance and safe procedure during insertion. Two cutting blades at the implant apex establish the self-tapping properties of the C1; supporting a simpler, safer and faster procedure.

Page 6: Implant Solutions Flier

10mm, 11.5mm, 13mm, 16mmØ3.30

8mm, 10mm, 11.5mm, 13mm, 16mmØ3.75

6mm, 8mm, 10mm, 11.5mm, 13mm, 16mmØ4.20

6mm, 8mm, 10mm, 11.5mm, 13mm, 16mmØ5

6mm, 8mm, 10mm, 11.5mm, 13mmØ6

MIS SEVEN self-tapping implants are designed for a wide range of bone types and bone augmentation procedures. Their unique geometric design features dual threads, three spiral channels stemming from the apex, micro-rings on the implant neck and a large pitch thread design. Each SEVEN implant comes with a single-use final drill to ensure a safer and more accurate drilling procedure.

Internal Hex. Connection

SEVEN implant dimensions

Page 7: Implant Solutions Flier

Internal hex.SEVEN implants feature an internal hex. connection, assuring proper implant abutment seating, anti-rotational engagement, resistance to lateral forces, excellent esthetic results and more.

Micro ringsMicro-rings at the neck of the SEVEN implant significantly increase the BIC (Bone to Implant Contact), avoiding bone resorption at the crestal zone.

Dual threadThe SEVEN dual thread design increases the BIC (Bone to Implant Contact) over the entire body of the implant, reinforcing Osseointegration for long lasting clinical success. Overall insertion rate of the SEVEN is 2.4mm per revolution.

Conical shapeConical, root-shaped geometry and a unique thread design ensure superior primary stability, offering the ultimate choice for a wide range of clinical cases and loading protocols.

Surface treatmentSEVEN implants are sand-blasted and acid etched. These surface treatments increase the implant surface area by creating both micro and nano-structures and eliminating various surface contaminants.

Three spiral channelsThree spiral channels at the apical end of the implant support its self tapping properties. The channels also collect and amass bone chips in the course of insertion, supporting efficient osseointegration and long-term stability.

Domed apexThe dome shaped apex prevents over-insertion for safer implant placement procedures.

Page 8: Implant Solutions Flier

10mm, 11.5mm, 13mm, 16mmØ3.30

6mm, 8mm, 10mm, 11.5mm, 13mm, 16mmØ3.75

6mm, 8mm, 10mm, 11.5mm, 13mm, 16mmØ4.20

6mm, 8mm, 10mm, 11.5mm, 13mm, 16mmØ5

6mm, 8mm, 10mm, 11.5mm, 13mmØ6

MIS M4 implants combine the benefits of cylindrical and conical implant designs, aiming to achieve excellent primary stability in every clinical scenario. The two main features of M4 implants are: Self-tapping, V-shaped thread design with three spiral channels, allowing smooth insertion even in type 1 bone conditions. A flat, cutting, tapered apex, enables instant grip into bone in immediate placement procedures.

Internal Hex. Connection

M4 implant dimensions

Page 9: Implant Solutions Flier

Internal hexagonM4 implants feature an internal hex. connection that ensures proper abutment seating, anti-rotational engagement, resistance to lateral forces, excellent esthetic results and more.

Combined cylindrical & conical body shape with V-shaped threadsThe implant body and thread shape is designed for mild bone compression while achieving maximum initial and long term stability.

Dual threadA dual thread design increases BIC (Bone to Implant Contact), reinforcing osseointegration for long lasting clinical success. The overall insertion rate of M4 is 1.6mm per revolution.

Surface treatmentsM4 implants are sand-blasted and acid etched. These surface treatments increase the implant surface area by creating both micro and nano-structures and eliminating various surface contaminants.

Three spiral channelsThree spiral channels at the apical end of the implant support its self-tapping properties. The channels also collect bone chips in the course of insertion, supporting efficient osseointegration and long-term stability.

Flat cutting apexA flat cutting apex allows for final adjustments during placement procedures.

Page 10: Implant Solutions Flier

8mm, 10mm, 11.5mm, 13mm, 16mmØ3.75

8mm, 10mm, 11.5mm, 13mm, 16mmØ4.20

8mm, 10mm, 11.5mm, 13mm, 16mmØ5

LANCE external hex. implants feature a unique thread design that enables a simplified surgical procedure, reducing the number of surgical stages. LANCE external hex. is the result of an extensive research and development process, resulting in a successful product, suitable for multiple clinical scenarios. Like all MIS products, LANCE implants comply with the most stringent international quality standards.

External Hex. Connection

LANCE implant dimensions

Page 11: Implant Solutions Flier

Surface treatmentLANCE implants are sand-blasted and acid etched. These surface treatments increase the implant surface area by creating both micro and nano-structures and eliminating various surface contaminants.

Mount adapterLANCE external hex. implants are assembled with a mount that fits all MIS surgical tools and allows quick, simple delivery. The mount is required to ensure the integrity of the external hex. connection during insertion.

Triple threadThree separate threads, 2.25mm apart, run the length of the conical body. The “Triple Thread” and conical body shape reduce insertion time compared to conventional implants, simplifying surgical proceduresand enabling smooth implant insertion.

Conical ShapeThe LANCE conical shape mimics natural roots. It is particularly suitable for placement between natural teeth or adjacent implants, and corresponds with the natural anatomy of the supporting bone. The conical shape of the LANCE is safer where space is restricted due to divergent roots of natural teeth.

Two spiral channels & domed apexLANCE features two spiral channels supporting the self-tapping properties of the implant to minimize friction. The dome-shaped apex prevents over-insertion for a safer implant placement procedure.

Page 12: Implant Solutions Flier

MIS Implants Technologies Ltd. www.mis-implants.com

MAKE IT SIMPLE®

MIS Implants Technologies Ltd.P.O.Box 7, Bar Lev Industrial Park,20156, ISRAELTell: +972 (0)4 90 16 800Email: [email protected]