integrated radiological protection system for an npp€¦ · 1matefin ltd, bucharest, romania....

21
S. Troto1, I. Vranceanu 1 , L. Toro 1,2 1 Matefin Ltd, Bucharest, Romania. 2 National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP XXXVIII. Sugárvédelmi Továbbképző Tanfolyam, Hajdúszoboszló, 2013. április 23-25

Upload: others

Post on 14-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

S. Troto1, I. Vranceanu1, L. Toro1,2

1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania

INTEGRATED RADIOLOGICAL

PROTECTION SYSTEM FOR AN NPP

XXXVIII. Sugárvédelmi Továbbképző Tanfolyam, Hajdúszoboszló, 2013. április 23-25

Page 2: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

• Any NPP is fully equipped with many monitoring equipments

• The systems dedicated to monitor radiations have continuously grown in number and complexity

• The main goal of radiological protection is to reduce the personal exposure levels

• For a proper optimization the information quality and quantity is critical

• To take full advantage of all data provided by these monitors (over 100 channels for each unit),

it is a must to view and consolidate all inputs into one central system.

• Storage of data

• Possibility of trend studies of the data

• Set/modify aquisition parameters

• Possible correlation between parameters

• Make all systems belonging to various generations, technologies and/or manufacturers to work

together

The answer: MTF-RMS (MaTe-Fin Radiological Monitoring System)

MTF-RMS CONCEPT MTF-RMS: the system of the systems

Page 3: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

• Generation I • For the first time in 2005, all data from

various radiation monitoring systems are put together.

• MTF-RMS generation I was built around the Ramvision software developed by MGP Instruments.

• MATE-FIN has also developed custom software for TAM, C&C monitors and portable monitors.

• There were separate servers for data collection and storage.

• Data were visualized via software clients, inside the local network.

• Generation II • The generation II is using the newest IT

technologies, like industrial Ethernet,

fiber-optic, virtual machine, etc.

• There is one central data-base with

modern data management: detailed

reports, data visualization, trends, etc.

• The system is redundant and flexible

• There is an unlimited number of clients

through the web interface (JSON / WCF

Webservice) accessible all over Intranet

MTF-RMS Short History

Page 4: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

MTF-RMS First Generation Cernavoda NPP Unit 2

RAMVISION manages

information from all MGP specific

systems

MF-AO manages information from Overhoff Tritium Monitors. The first attempt to monitor on-line the H3 and

integrate into a RMS system .

MF-AR manages information

from all Contamination Monitors

The main components of the

MTF-RMS for NPP Cernavoda Unit 2 are 7 computers linked into a LAN. They are responsible for making the link with fildbuses with different systems scattered all over the site. There is a central SQL DB server who stores the

data.

ETHERNET

Co

nn

ectio

n

LEM&GEM

Fieldbus

Co

nn

ectio

n

C&C

Fieldbus

Co

nn

ectio

n

TAM

Fieldbus

Co

nn

ectio

n

PAASM

Fieldbus

Co

nn

ectio

n

PORTABLE

Fieldbus

Co

nn

ectio

n

SMFG

Fieldbus

SERVER

SQL

DB

The system is on service from 2006, based on MGP software RAMVISION and in-house software MF_AO and MF_AR

Page 5: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

The second generation newer technology: VMware vSphere HA. Virtualized IT

environment is a 100% client -server application. The architecture is divided into 3 main components: • The acquisitions tasks are distributed to specific hardware TCP/Fieldbus gateways

and all protocols are converted to TCP/MODBUS protocol. • The data processing servers like SQL, OPC, Backup or WEB, and the application software itself, are located on different VM. • The clients can be any computer with IE

and Excel to view data and generate reports. Optional, different interfaces are available.

MTF-RMS - Second Generation

Page 6: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

• AAGM, with its 35 channels, provides real-time measurements of Gamma levels (reactor building and the service building)

• Channels installed inside the reactor

building have ionization chambers and Si detectors with special mineral cables, allowing to operate in high gamma and neutron fields for at least 30 years

• MGP Instruments (part of MIRION Group, France) equipment

• Unit 1: all original equipment was replaced after 15 years of operation (MATE-FIN)

• Unit 2 reactor building: channels upgraded (MATE-FIN)

• AAGM both in unit 1 and 2 are under full

maintenance by MATE-FIN.

AAGM Gamma Area Monitors

Channel Acquisition interface Unit

AL DR MTF-Gateway RS-485

mSV/h

Dose Rate MTF-Gateway RS-485

mSV/h

Door MTF-Gateway RS-485

N/A

LowCps MTF-Gateway RS-485

c/s

HighCps MTF-Gateway RS-485

c/s

Temp MTF-Gateway RS-485

Deg.C

TID MTF-Gateway RS-485

mSv

Dose MTF-Gateway RS-485

mSv

DoseR1 MTF-Gateway RS-485

mSv/h

Page 7: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

LEM ON LINE

LEM Liquid Effluent Monitor

Critical system, redundant configuration

LEM OFF LINE

There are two independent systems made by MGP Instruments, which drive the valve PV54 responsible for

liquid discharge. Thanks to that configuration, we get a zero time for maintenance.

Page 8: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

LEM Liquid Effluent Monitor Channel Aquisition

interface

Unit

LEM ONLINE

LiqAct MTF Gateway RS-485 Bq/ml

Discharg MTF Gateway RS-485 l/h

CS137CPS MTF Gateway RS-485 c/s

GrosWin1 MTF Gateway RS-485 c/s

GrosWin2 MTF Gateway RS-485 c/s

Temp MTF Gateway RS-485 ºC

DO1 MTF Gateway RS-485 N/A

LEM OFFLINE

BkgAct MTF Gateway RS-485 Bq/ml

Discharg MTF Gateway RS-485 l/min

VolAct MTF Gateway RS-485 Bq/ml

Cs137Cps MTF Gateway RS-485 c/s

Win1Cps MTF Gateway RS-485 c/s

Win2Cps MTF Gateway RS-485 c/s

Temp MTF Gateway RS-485 ºC

Page 9: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

GEM Gaseous Effluent Monitor - Critical system

Monitors the stack gases,

using isokinetic sampling,

by:

• ABPM - Particulate Monitor

•16 acquisition channel

• IM - Iodine Monitor •13 acquisition channel

• NGM - Noble Gas Monitor •17 acquisition channel

• Passive samplers for H3

and C14

Page 10: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

GEM Spec Additionally, the noble gases release is monitored on-line for ten different isotopes, by Gamma spectrometry. All history and spectra are stored into an Oracle SQL DB. Many analysis and reports are available 10 acquisition channel

Page 11: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

PAASM Post Accident Air Sampling Monitor

• IM-Iodine Monitor •7 acquisition channel

• NGM-HR •9 acquisition channel

• NGM-LR •7 acquisition channel

• H3 Sampler

Page 12: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

TAM - Tritium in air monitor Architecture overview

MS SQL

RETEA PROFIBUS

CPM

TAM1

PLC S7-300

PL1398

CPM

TAM2

PLC S7-300

PL7201

CPM

TAM3

PLC S7-300

PL7301

CPM

TAM4

PLC S7-300

PL7401

HMI

TAM1

TP277 6'

PL1398

HMI

TAM2

TP270 10'

PL7201

HMI

TAM3

TP277 6'

PL7301

HMI

TAM4

TP270 10'

PL7401

MPI

BUS

MPI

BUS

MPI

BUS

MPI

BUS

WINCC runtime +licente

PC-HMIOPC-

SERVERPC-SQL

CALCULATOR DE PROCES

S115

CPM

TAM5

PLC S7-300

PL7501

HMI

TAM5

TP270 10'

PL7501

MPI

BUS

The latest generation of TAM is working at

Cernavoda NPP Unit1 since 2010.

•New concept, using the power of PLC to

optimize the sampling process.

• All information are available using a HMI

interface, locally and remote.

•six hour memory buffer for each monitor to

save the measurements in case of SQL server

malfunction.

Page 13: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

TAM Tritium in Air Monitors

TAM is a MATE-FIN design • Overhoff 357 H3 monitors • custom sampling system

based on PLC technology. • Over forty locations (reactor

building and service building) •U1 – 5 monitors, 42

sampling location •U2 – 8 monitors, 32

sampling location • Complex scanning algorithms

•the system is able to locate very quickly any leak of heavy water.

Flow sheet example of sampling system Screenshot from the main computer

SCHEMA TEHNOLOGICA TAM 4

V 4

.12

V 4

.15 -

R502

V 4

.16 -

R502

R501

SV

4.P

R501

M 4

R502

DR 4

R501

P4

V 4

.13 At 6A-83 line inlet (cota

124.28) - D2O Recovery

System

P 4

R501

FFM 4.17

Intr

e 3

211-P

1 s

i P

2, co

ta

103.0

0

PP23

Deasupra

32

11-T

K1,

intr

e g

urile

de v

izitare

la

niv

elu

l p

ere

telu

i, c

ota

112.5

0

PP22

Lin

ga 3

231-R

D3, cota

117.4

5

PP32Lin

ga 3

231-R

D4, cota

117.4

5PP33

Gale

rie S

RA

ZA

fata

C,

din

co

lo d

e z

ona v

anelo

r

333

2-M

V1/M

V2, co

ta

112.4

5

PP26

Boxa P

resurizor

prim

ul

niv

el, lin

ga 3

33

2-P

V3,

cota

121.0

0

PP27

Deasupra

33

33-T

K1,

cota

128.1

2

PP28

Gale

rie S

RA

ZA

fata

A,

zona v

ane

lor

3335-M

V1

- M

V4, cota

112.4

5

PP25

Punct R

efe

rinta

cota

117.4

5

PP29

Lin

ga 3

231-R

D1, cota

117.4

5

PP30

Lin

ga 3

231-R

D2, cota

117.4

5

PP31

COLECTOR

PL 1

R501

MCU 4.1 MCU 4.2 MCU 4.3 MCU 4.4 MCU 4.5 MCU 4.6 MCU 4.7 MCU 4.8 MCU 4.9 MCU 4.10 MCU 4.11

FC

V 4

.18

- R

20

1

R501 R501 R501

AE

R

FA

LS

SV#

Electroventil

F

FM#.2

FM electronic

V#

Robinet ac

FI

FM#.1

FM bila

MCU#

tip2

Co

ne

cto

r

co

mp

resie

Co

ne

cto

r

co

mp

resie

V….

P...

Racord “T”

ventil izolare

manual

ventil

sens

Pomp

a

Gura de prelevare

Teava impuls 1/2" // 3/8" // 1/4"

SV4.P

Electroventil “on/off” 1/2" - purja

Filtru HEPA

M #

Cam #

DR #

Cam #

Monitor Tritiu # in camera #

Uscator Monitor Tritiu # in camera #

LEGENDA

FFM 4.# Traductor debit aferent TAM 4 #

MCU#Unitate Masura & Control debit tip 2

(Vezi Nota 2)

FCV...

Electroventil proportional

Page 14: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

• After the TAM has become operational, the personnel Tritium doses have decreased significantly.

• There is no need anymore to deploy personnel for manual measurement of Tritium levels.

• Data provided by TAM are used to optimize the functioning of dryers in the ventilation system.

TAM benefits Tritium doses have decreased significantly

Page 15: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

C&C

Contamination and clearance monitors

• hand and foot monitors installed inside

the power-plant, at the cross-border of

zone 1 and zone 2,

• total body contamination monitors

installed at the exit of zone 2.

(RADOS Technologies Finland, part of

MIRION group)

Channel Interfata Achizitie Unit

Normal operation/failure MTF-Gateway DI N/A

Contamination MTF-Gateway DI N/A

Measurement under contamination level

MTF-Gateway DI N/A

Page 16: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

MTF-RMS has also the possibility to connect with mobile monitors (gamma, neutron, tritium, particulate, etc.)

Portable monitors are connected to MTF-RMS via sockets installed inside the power-plant, and the data are collected, displayed and stored by the central system

Automatic identification of instrument type and location

Portable Portable and mobile monitors

Page 17: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

• 12 sampling stations installed around

the power-plant for continuous

sampling of environmental air for

off-line measurement of Tritium,

Iodine and radioactive particles • 19 acquisition channel

(F&J Specialty Products USA,

integrated by MATE-FIN)

CEAS

Continuous Environmental Air Samplers

Page 18: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

Mobile radiological laboratory, integrated into the MTF-RMS, equipped with:

• ABPM - Particle Monitor

• IM - Iodine Monitor

• Gamma monitor

• Weather Station

• GPS System

All information are remotely stored in a database server for later reporting and analyze.

MTF-MOBCAR Radiological Emergency Lab

MF-ADMIR - local software

that collects and sends all

information to the SQL server

Page 19: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

And finally, probably the most important of the systems: “The Open Door”

Based on open standards like Profibus, Profinet, Modbus, OPC and SQL server, MTF-RMS keeps the door open for future systems and, even more, for the future systems of Units 3 and 4.

Open Door MTF-RMS: the system of the systems

Page 20: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

• This system measures and records the

Gamma dose for each worker entering

the radiological area. The system consists,

for each unit, of 200 Personal Alarming

Dosimeters (PAD), together with 6

readers. All data, from all units, are

collected by one central database server

• Dosimetry and teledosimetry systems in

Cernavoda NPP were provided by

MATE-FIN, using equipment

manufactured by MGP Instruments

France, part of MIRION group.

• Dosimetry systems are maintained by

MATE-FIN under maintenance contract

signed with Cernavoda NPP

Personal dosimetry Personal Dosimetry and Teledosimetry

Page 21: INTEGRATED RADIOLOGICAL PROTECTION SYSTEM FOR AN NPP€¦ · 1Matefin Ltd, Bucharest, Romania. 2National Institute of Public Health, Bucharest, Romania INTEGRATED RADIOLOGICAL PROTECTION

THANK YOU FOR YOUR ATTENTION

QUESTIONS

COMMENTS