internet telephonyindustrial strength and mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. ·...
TRANSCRIPT
![Page 1: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/1.jpg)
Siemens 1
Industrial Strength and MobileInternet Telephony
Henning SchulzrinneDept. of Computer Science
Columbia UniversityNew York, New York
Siemens Visit (Munich)
October 27, 2000
Joint work with Jonathan Rosenberg, SIP IM/presence group, Telcordia, Columbia IRTresearch group
October 2000
![Page 2: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/2.jpg)
Siemens 2
Overview
� industrial-strength VoIP and presence services
– scaling
– redundancy and fault tolerance
– network management
– administration
– integration
� using SIP for supporting facets of mobility
October 2000
![Page 3: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/3.jpg)
Siemens 3
SIP Servers and Clients
UAC: user-agent client (caller application)
UAS: user-agent server➠ accept, redirect, refuse call
redirect server: redirect requests
proxy server: server + client
registrar: track user locations
� user agent = UAC + UAS
� often combine registrar + (proxy or redirect server)
October 2000
![Page 4: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/4.jpg)
Siemens 4
Design Goals
� 5-nines reliability
� scalability to major domains likeaol.com, siemens.com or t-online.de
� commodity unreliable hardware (PCs)
� commodity software for databases and directories
� avoid clustering software
October 2000
![Page 5: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/5.jpg)
Siemens 5
Scaling
� SIP signaling primarily handled by SIP proxies, with associated registrars andlocation servers
� critical – common infrastructure for IM/presence, VoIP, conferences, mobilenetworks, . . .
� SIP proxies do not switch voice, but
– route calls – mobility
– implement policies
– programmable logic
� far higher variability than classical switches: execute subscriber-defined codeduring call signaling:
– sip-cgi scripts (similar to web cgi-bin scripts)
– CPL scripts – XML-based call logic
October 2000
![Page 6: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/6.jpg)
Siemens 6
Scaling
� call routing: no “area codes”➠ email-style addresses, with allatt.com throughsingle (logical) proxy
� but: easier to scale due to higher signaling bandwidth
� transmission delay: 288�s/message for 10 Mb/s Ethernet (typical: 360 bytes)
October 2000
![Page 7: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/7.jpg)
Siemens 7
Scaling or How Many Calls can a SIP Switch Switch?
Some metrics:
� BHCA – 750,000 to 2.5 million busy hour call attempts for large class-5 switches= 3.6 ms/call
� AT&T: 280 million calls a day = 0.3 ms/call
� Yahoo: 780 million page views/day
� AOL: 110 million emails/day
� AOL: 500 million IM/day
� web server: about 1,500 to 3,000 static requests/second
October 2000
![Page 8: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/8.jpg)
Siemens 8
Signaling Load Components
INVITE
sip−cgiscript
address
DNS SRV lookupLDAPlookup
SQLlookup/update
registration, scriptlookup
next−hop resolution
scriptaliases
October 2000
![Page 9: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/9.jpg)
Siemens 9
Typical Signaling Processing Steps
1. parse incoming SIP request
2. possibly invoke a generic administrative script
3. map aliases (e.g.,peter.ford �! pf ) in local database to canonical identifier
4. check registration in LDAP or via SQL query
5. invoke per-user cgi script
6. translate host name
7. forward request, response
8. log request
October 2000
![Page 10: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/10.jpg)
Siemens 10
SIP Scaling Differs From Other Internet Protocols
� not CPU-bound➠ delay 6= 1/throughput
� low byte volume➠ easy to physically distribute for redundancy and loaddistribution
� servers can easily be shared among domains
October 2000
![Page 11: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/11.jpg)
Siemens 11
Signaling Load Distribution
ease depends on service model: SIP proxy, redirect, registrar
SRV 1 0 5060 sip.backup.com_sip._udp.example.com
sip−server.asp.com
sip.backup.comif failure
SRV 0 0 5060 sip−server.asp.com
DNS
October 2000
![Page 12: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/12.jpg)
Siemens 12
DNS SRV Records
� DNS SRV records: priority and weight
_sip._tcp SRV 0 0 5060 sip-server.cs.columbia.edu.SRV 1 0 5060 backup.ip-provider.net.
_sip._udp SRV 0 0 5060 sip-server.cs.columbia.edu.SRV 1 0 5060 backup.ip-provider.net.
� clients try hosts in order of priority, then balance requests randomly scaledaccording to weight
October 2000
![Page 13: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/13.jpg)
Siemens 13
Signaling Load Distribution
� doesnot take current load into account
� hot spots?
� SIP allows per-transaction routing of requests, withRoute header for routingsubsequent transactions
� Route can be either specific domain or IP address OR SRV
� proposal to allowRoute also for first request
� if call state, more difficult to fail-over mid-call➠ need back-end statesynchronization
October 2000
![Page 14: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/14.jpg)
Siemens 14
Other Load Components
Full characterization requires dimensioning other servers:
� SQL or in-memory databases for authentication and registration
– storage requirement depends onContact length
– from� 50 to 1,000s bytes/client
� LDAP servers – about 180 searches/second?
� media servers for voicemail and IVR
� conferencing servers – primarily media/computation-limited
With roughly hourly SIP registration updates, writes can dominate – campus with20,000 devices➠ 5.5 updates/second
October 2000
![Page 15: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/15.jpg)
Siemens 15
Fault Tolerance
� failure of proxies does not affect (most) existing calls
� possible exceptions: firewall proxies
� mid-call requests viaRoute can use different server, if DNS SRV used as address
� registration information:
– is refreshed roughly hourly
– multicast
– forking registrations
– our SLP synchronization work?
– recovery after reboot➠ persistent memory
� PSTN gateway location➠ TRIP
October 2000
![Page 16: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/16.jpg)
Siemens 16
Administration
� phone administration across platforms
� local user registration
– anybody can register
– web page
– inherit from other database (AAA, RADIUS, LDAP, /etc/passwd,. . . )
October 2000
![Page 17: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/17.jpg)
Siemens 17
Administering Authentication
� PGP or S/MIME certified by third party
� carrier-based authentication, signed by proxy➠ “DT certifies that this customer iscalled Lieschen M¨uller” or “this caller is calling from the premises of Visa”
� per-callee user name(s) and passwords: “friends/secret”
� per-domain identitieswith global identifiers
October 2000
![Page 18: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/18.jpg)
Siemens 18
Example: Columbia Internet Extensible Multimedia Architecture
request, responsetransactioncgi scriptsbasic authenticationdigest authentication
libsip
sipum
SIP UAcall stateREGISTERendpoint classSDP
siph323 sipconf
lipsip++
sipdrtspd
PGP
LDAP
SIP proxy server
libNT
SIP conferencing server
NT versions of aliases crypt
PGPPWLresparse
libdict
dictionary
hash tables
libmixer
hashtable inet regex getopt utilities
dstringhost2ip
mix RTP audio
SIP/RTSP unified messagingSIP/H.323 gateway
MySQLMySQL
SIP/MGCP gatewayRTSP media server
GSM, DVI codecs
msgflow
OpenH323 AT&T MGCP
CINEMA
sipgw
Xerces
config./DB access
libcine
parserURIsloggingMD5
software licensingTCPUDP
RTPlib
October 2000
![Page 19: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/19.jpg)
Siemens 19
Single Sign-On
Uses per-domain identities
October 2000
![Page 20: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/20.jpg)
Siemens 20
CINEMA Registration
Email send [email protected] :
Subject: Your CINEMA registrationDate: Tue, 24 Oct 2000 21:48:09 -0400 (EDT)From: <[email protected]>To: [email protected]
Your new CINEMA password for cs.columbia.edu is"deduct.transversal.desert".The realm is "Password for cs.columbia.edu".
October 2000
![Page 21: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/21.jpg)
Siemens 21
User Administration
October 2000
![Page 22: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/22.jpg)
Siemens 22
CINEMA Policies
� third-party registration: “Anne and Bob are allowed to register for me”
� execution of scripts
� services: voicemail, conferencing, . . .
October 2000
![Page 23: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/23.jpg)
Siemens 23
Network Management for SIP Servers
� SIP MIB, draft-ietf-sip-mib-01
� configuration description (outbound proxy,. . . )
� request statistics, method statistics
� current transactions
� working on initial implementation insipd server
October 2000
![Page 24: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/24.jpg)
Siemens 24
Mobility in an IP environment
Roaming users: logging in away from home network: hotel, home office
Terminal mobility: terminal moves between subnets
Personal mobility: different terminals, same address
Service mobility: keep same services while mobile
Session mobility: move active session between terminals
October 2000
![Page 25: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/25.jpg)
Siemens 25
Simple Mobility: Roaming Users
� users visit other networks: laptop, PDA, hotel phone, . . .
� want to maintain external identity
� usually, just pass IP address to home registrar
� difficult if firewalls and NATs
– requests need to use local proxy
– thus, need to register locally
� also may want to use home services while traveling
October 2000
![Page 26: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/26.jpg)
Siemens 26
Roaming Users
Hotel California
Contact: sip:128.59.16.1From: [email protected]: [email protected]
From: [email protected]: [email protected]
REGISTER sip:home.comREGISTER sip:home.com
Contact: sip:128.59.16.1
DHCPserver
IP: 128.59.16.1
SIP: sip.hotelca.comDNS: hotelca.com
From: eagles%[email protected]: eagles%[email protected]
REGISTER sip:sip.hotelca.comhome.comsip.hotelca.com
October 2000
![Page 27: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/27.jpg)
Siemens 27
Terminal mobility
� domain of IEEE 802.11, 3GPP, mobile IP, . . .
� main problems:
– handover performance
– handover failure due to lack of resources in new network
– authentication of redirection
October 2000
![Page 28: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/28.jpg)
Siemens 28
Personal mobility
tel:12015551234
tel:12128541111
(also used by [email protected])
yahoo.com
columbia.edu
October 2000
![Page 29: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/29.jpg)
Siemens 29
Personal mobility
� switch between PDA, cell phone, PC, Ethernet phone, Internet appliance, . . .
� several “generic” addresses, one person/function, many terminals
� e.g.,tel:2129397042 , [email protected] ,[email protected] or [email protected]
� SIP is designed for that – proxying and redirection does translation
� but: need mapping mechanisms to recognize registrations as belonging to thesame person
� some possible solutions:
– dip into LDAP personnel database or/etc/passwd to match phone numberand variations of name (J.Doe, John.Doe, Doe)
– need dialing plan to [email protected] andtel:2129397042 as same
October 2000
![Page 30: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/30.jpg)
Siemens 30
Service mobility
Examples:
� speed dial & address book
� media preferences
� special feature buttons (voice mail, do-not-disturb)
� incoming call handling instructions
� buddy lists
�! independent of terminal (including pay phone!), across providers
October 2000
![Page 31: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/31.jpg)
Siemens 31
Service mobility
� REGISTER can retrieve configuration information (e.g., speed dial settings,distinctive ringing or voice mail settings)
� but needs to be device-independent
� most such services (e.g., voicemail forwarding, call filtering) should remain onserver(s)
Separate issue: how does the payphone (or colleague’s phone) recognize you?
� PDA (IR)
� i-button
� fingerprint
� speech recognition, . . .
One device, but changing set of owners!
October 2000
![Page 32: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/32.jpg)
Siemens 32
Service mobility – call handling
� need uniform basic service description model�! Call Processing Language(CPL)
� CPL = XML-based flow graph for inbound & outbound calls
� CPL for local call handling
� update CPL from terminal: add telemarketer to block list
� harder: synchronize CPL changes across multiple providers
� one possibility:REGISTER updates information, but device needs to know that ithas multiple identities
� merging of call logs
October 2000
![Page 33: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/33.jpg)
Siemens 33
Terminal mobility – details
� move to new network➠ IP ad-dress changes (DHCP)
� mobile IP hides addresschanges
� but: little deployment
� encapsulation overhead
� dog-legged routing
� may not work with IP addressfiltering
CN
CH
HA
FAtunnelleddatadata
data
data
home network
foreignnetwork
mobile hostcorrespondent hostrouter with home agentfunctionalityrouter with foreign agentfunctionality
MH
CH
HA
HA
MH
MH
October 2000
![Page 34: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/34.jpg)
Siemens 34
SIP terminal mobility overview
� pre-call mobility➠ SIP proxy, redirect
� mid-call mobility ➠ SIP re-INVITE, RTP
� recovery from disconnection
October 2000
![Page 35: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/35.jpg)
Siemens 35
SIP terminal mobility: pre-call
� MH acquires IP address viaDHCP
� optional: MH finds SIP servervia multicastREGISTER
� MH updates home SIP server
� optimization: hierarchical LR(later)
CH
redir
3
1
2
5
foreignnetwork
homenetwork
4
mobile hostcorrespondent host
SIP redirect server
MH
CH
redir
3
1
2
5
4
SIP INVITE
SIP 302 moved temporarily
SIP INVITE
SIP OK
dataMH
MH
October 2000
![Page 36: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/36.jpg)
Siemens 36
SIP terminal mobility: mid-call
� MH!CH: new INVITE, withContact and updated SDP
� re-registers with home regis-trar
CH
13
2
foreignnetwork
homemobile hostcorrespondent host
SIP redirect server
MH
CH
redir
3
1
2
SIP INVITE
SIP OK
data
redir
network
MH
MH
MH
October 2000
![Page 37: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/37.jpg)
Siemens 37
SIP terminal mobility: multi-stage registration
Don’t want to bother home registrar with each move
Contact: alice@CAFrom: alice@NY
Contact: 193.1.1.1
REGISTERINVITE
Los Angeles
San Francisco
Contact: 192.1.2.3From: alice@NY
CA NY
From: alice@NY
October 2000
![Page 38: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/38.jpg)
Siemens 38
SIP and mobility: issues
� doesn’t work for TCP applications – solutions:
– punt: “don’t walk while telnet’ing”
– application-layer awareness: restart web, email, ftp transfer – need for deepfade anyway. . .
– NAT-style boxes controlled by SIP (see Telcordia ITSUMO project)
� but: works nicely for “vertical handoff” between different technologies - e.g.,transfer call from mobile handset to office videophone when arriving at work
October 2000
![Page 39: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/39.jpg)
Siemens 39
Scaling & Reliability: Open Issues
� performance of real servers
� design alternatives: thread models,select() , etc.
� external server access models vs. in-memory databases
� impact of security
� single sign-on
� cryptographic certificates
� fail-over, state recovery
October 2000
![Page 40: Internet TelephonyIndustrial Strength and Mobilehgs/papers/2000/siemens.pdf · 2003. 3. 25. · Siemens 1 Industrial Strength and Mobile Internet Telephony Henning Schulzrinne Dept](https://reader035.vdocuments.net/reader035/viewer/2022071608/6145e75b8f9ff812541fec70/html5/thumbnails/40.jpg)
Siemens 40
Mobility: Open Issues
� hand-off performance
� simultaneous moves
� address hiding?
� co-existence with mobile IP
– hand-off to non-MIP networks
– avoiding IPv4 dog-legged routing for multimedia
http://www.cs.columbia.edu/sip