lighting systems & controls application 2017 retrofit program · • product types eligible for...
TRANSCRIPT
-
Page 1 of 12 Rev. 1/6/2017
Eligibility:• Must be an Upstate New York National Grid Commercial Electric Account holder and pay into the System Benefits Charge (SBC).
IRS recognized farms and religious organizations may also be eligible if they pay into the SBC. Please verify with a copy of aNational Grid electric utility bill.
• Product types eligible for prescriptive lighting retrofit and controls incentives are included in Tables 1A (Lighting Systems Eligibility andIncentives) and 1B (Lighting Controls Eligibility and Incentives) attached to this application. Measures not listed on this application maybe eligible for incentives under our Custom C&I Retrofit program. Please contact your National Grid Representative for additional details.
Pre-Approval Requirements:
• Only completed applications will be considered and reviewed for incentive eligibility.• All projects require a pre-inspection prior to National Grid issuing an incentive offer letter.• BEFORE purchasing and installing the equipment, ensure the project is eligible for an incentive.• National Grid account number, Federal Tax ID numbers and a W-9 form for the customer must be provided.• Be sure to identify the customer or installation contractor receiving the incentive and where the check is to be sent.
Application Steps:
• Complete the Excel file of the lighting and control measures and system inventory spreadsheet. If you do not have access to Excelor use a version older than 2010, please fill out the Lighting Systems Inventory Worksheet (Table 2A) and Lighting Control(s) InventoryWorksheet (Table 2B) if controls are part of the project. Return either the spreadsheet or the completed tables as part of your completepackage submitted to National Grid.Please refer to the NYS Device Codes chart or speak with your National Grid Representative foraccepted codes and wattages.
• Proposed equipment manufacturer’s technical specification sheets (“cut sheets”) for each type of installed equipment must be providedwith the application.
• Project must include labor and material cost.
• All LED fixtures must be Design Lights Consortium (DLC) qualified and LED bulbs must be ENERGY STAR LED products notfound on Energy Star or DLC qualified products lists may be eligible for incentives if found on Lighting Design Labs (LDL) qualified product list.
TM qualified.
Installation and Payment Steps:
• Once a completed application is reviewed and meets the minimum energy savings requirements, an incentive is calculated and offerletter is provided to the customer and/or installation contractor for review and signature.
• The customer and/or installation contractor must:
• Purchase and install equipment within 180 days upon receipt of the pre-approval letter.
• Verify installation by providing a signed signature page from the customer report (“Certification of Installation”)
• Provide a copy of a paid invoice on company letterhead indicating type, size, make, model and quantity of equipment andinclude burdened project labor costs.
• Return all required information to National Grid within 30 days of the installation.
The Retrofit Program is designed for Commercial and Industrial (C&I) customers to help replace aging and inefficient equipment and systems with more energy efficient technologies. This type of prescriptive application provides a pre-determined incentive amount based on calculated energy savings to help expedite a customer’s incentive processing and improve their return on investment as a result of improved energy savings, increased safety, and improved productivity that comes with more energy efficient lighting.
Application and InstructionsThis application is designed for the replacement of existing operating equipment:
Program Details:
• This Retrofit program covers applications created on or after January 1, 2017. Details of this Program, including incentive levels,are subject to change without prior notice. The prescriptive application and all required documents must be provided as a completepackage in one email to your NG Representative, otherwise it will be placed on hold.
Lighting Systems & Controls 2017 Retro�t Program UNY
Lighting Systems & Controls Application2017 Retrofit Program
1-800-787-1706 / Fax: 1-315-460-9803
[email protected] / www.ngrid.com/unybiz
-
Page 2 of 12
ALL FIELDS ON THIS PAGE ARE REQUIRED.
CUSTOMER/ACCOUNT HOLDER INFORMATION (Customer must submit a W-9 Form)CUSTOMER FACILITY NAME CONTACT PERSON APPLICATION DATE
PHONE FAX NUMBER CUSTOMER FEDERAL TAX ID NUMBER
EMAIL ADDRESS SQUARE FEET (COVERED BY THIS APPLICATION)
STREET ADDRESS CITY STATE ZIP
COMPANY TYPE:
INCORPORATED EXEMPT NOT INCORPORATED CLASSIFICATION TYPE:
> 2MW (LARGE) 2MW LARGE COMMERCIAL USE THE < 2MW CLASSIFICATION
CUSTOMER OF RECORD: BILLING ACCOUNT NUMBER: (REQUIRED)
BUILDING TYPE (SELECT ONE)
ASSEMBLY FAST FOOD HOTEL
RELIGIOUS
SMALL RETAIL AUTO REPAIR FULL SERVICE RESTAURANT
MULTIFAMILY HIGH-RISE UNIVERSITY
BIG BOX GROCERY
LARGE OFFICE
MULTIFAMILY LOW-RISE
SMALL OFFICE WAREHOUSE
COMMUNITY COLLEGE
HIGH SCHOOL LIGHT INDUSTRIAL
PHARMACEUTICAL
COLLEGE DORMITORY
HOSPITAL
MOTEL
INSTALLATION CONTRACTOR INFORMATION
ELEMENTARY SCHOOL HEAVY INDUSTRIAL
FOOD & BEVERAGE
LARGE RETAIL
REFRIGERATED WAREHOUSE
PRIMARY METALS OTHER:
INSTALLATION COMPANY CONTACT PERSON
STREET ADDRESS CITY STATE ZIP
PHONE EMAIL ADDRESS
Rev. 1/6/17
COMPANY TYPE FEDERAL TAX ID NUMBER (REQUIRED IF RECEIVING INCENTIVE)
MAILING ADDRESS (IF DIFFERENT) CITY STATE ZIP
INSTALL SITE
INCENTIVE PAYMENT
BUSINESS NAME CONTACT PERSON
STREET ADDRESS CITY STATE ZIP
PHONE EMAIL ADDRESS
CUSTOMER ADDRESS ABOVE INSTALLATION CONTRACTOR OR EQUIPMENT VENDOR ADDRESS OTHER (FILL OUT BELOW)
COMPANY TYPE FEDERAL TAX ID NUMBER (REQUIRED IF RECEIVING INCENTIVE)
- - - -
/ /
- -
- -
Lighting Systems & Controls 2017 Retrofit Program UNY
Lighting Systems & Controls Application 2017 Retrofit Program
1-800-787-1706 / Fax: 1-315-460-9803
[email protected] / www.ngrid.com/unybiz
-
Page 3 of 12
ADDITIONAL APPLICATION INFORMATION EXPECTED COMPLETION DATE OF PROJECT
Rev. 1/6/2017
TOTAL COST OF LABOR AND MATERIALS FOR INSTALLED LIGHTING AND/OR CONTROL EQUIPMENT*
CUSTOMER ACCEPTANCE OF TERMS I CERTIFY THAT ALL STATEMENTS MADE IN THIS APPLICATION ARE CORRECT TO THE BEST OF MY KNOWLEDGE AND THAT I HAVE READ
AND AGREE TO THE TERMS AND CONDITIONS OF NATIONAL GRID’S RETROFIT PROGRAM.
BY (AUTHORIZED SIGNATUIRE)
PRINTED NAME
TITLE
COMPANY
DATE
EQUIPMENT VENDOR INFORMATIONEQUIPMENT VENDOR COMPANY CONTACT PERSON
STREET ADDRESS CITY STATE ZIP
PHONE EMAIL ADDRESS
COMPANY TYPE FEDERAL TAX ID NUMBER (REQUIRED IF RECEIVING INCENTIVE)
*AN ACTUAL INVOICE ON COMPANY LETTERHEAD IS REQUIRED TO BE SUBMITTED TO NATIONAL GRID BEFORE FINAL PAYMENT OF INCENTIVE. $
- -
/ /
Lighting Systems & Controls 2017 Retrofit Program UNY
1-800-787-1706 / Fax: 1-315-460-9803
[email protected] / www.ngrid.com/unybiz
Lighting Systems & Controls Application 2017 Retrofit Program
-
Ta
ble
1A
:L
igh
tin
gS
ys
tem
sE
lig
ibil
ity
an
dIn
ce
nti
ve
Le
ve
ls(
Co
mp
lete
Ta
ble
2A
for
Lig
hti
ng
Syte
mIn
sta
lla
tio
ns
)
Measu
re
Co
de
Measu
reD
escri
pti
on
Per
Un
it
Incen
tive
Eli
gib
ilit
yC
rite
ria
Min
Watt
s
Saved
Imag
e
10Fl
uore
scen
tRed
uced
Wat
tage
T-8
orT-
5R
e-la
mp
and
Re-
balla
st$1
0
Re-
lam
p/re
-bal
last
ofex
istin
gfix
ture
sw
ithT-
8or
T-5
lam
ps,e
ach
fixtu
reis
com
pose
dof
balla
stan
d1,
2,3
or4
lam
ps.
Onl
yon
ein
cent
ive
may
beco
unte
dpe
rfix
ture
.Mul
tiple
fixtu
res
serv
edby
asi
ngle
balla
star
eon
lyel
igib
lefo
rone
ince
ntiv
e.
11
12Fl
uore
scen
tRed
uced
Wat
tage
T-8
orT-
5R
e-la
mp
and
Re-
balla
st$1
5R
e-la
mp/
re-b
alla
stof
exis
ting
fixtu
res
with
the
oppo
rtuni
tyfo
rinc
reas
edsa
ving
sof
mor
eth
an23
wat
ts.C
onsi
deru
sing
redu
ced
wat
tage
(25W
and
28W
)T-8
lam
ps.
23
81A
Inte
gral
LED
Scre
w-in
and
Pin
Base
dD
irect
iona
lRep
lace
men
tLam
ps$5
Elig
ible
LED
scre
w-in
and
pin
base
ddi
rect
iona
lint
egra
lrep
lace
men
tlam
psin
clud
e:M
R16
,PAR
16,a
ndPA
R20
,A-li
ne,c
andl
e,an
dde
cora
tive
glob
ela
mps
.Pl
ease
chec
kw
ithyo
urN
atio
nalG
ridre
pres
enta
tive
fore
ligib
ility
ofot
hero
mni
dire
ctio
nala
ndde
cora
tive
lam
pty
pes.
Req
uire
dto
belis
ted
byEn
ergy
Star
.
12
81B
Inte
gral
LED
scre
w-in
Dire
ctio
nal
Rep
lace
men
tLam
ps–
PAR
and
Scre
wBa
seLE
DD
own
Ligh
tRet
rofit
Kits
$15
Elig
ible
LED
scre
w-in
dire
ctio
nali
nteg
ralr
epla
cem
entl
amps
incl
ude:
PAR
30,
BR30
,and
PAR
38.A
lso
Elig
ible
;Scr
ewBa
seLE
DD
own
Ligh
tRet
rofit
Kits
.R
equi
red
tobe
liste
dby
Ener
gySt
ar.
25
$4(p
erla
mp)
$6(p
erla
mp)
$8(p
erla
mp)
Tab
le1A
.1:
Re-
lam
p&
Re-
bal
last
Rep
lace
men
tO
pti
ons
81C
LED
2 ft
., 3
ft., a
nd 4
ft. L
inea
r and
U-B
end
Rep
lace
men
t Lam
ps (U
L Ty
pe A
) an
d La
mp
Styl
e R
etro
fit-K
its (U
L Ty
pe C
) are
requ
ired
to b
e lis
ted
by th
e D
esig
nLig
hts
Con
sorti
um®
and
mus
t mee
t DLC
tech
nica
l req
uire
men
ts #
17,
#18,
or #
19.
Min
imum
of 2
,000
ann
ual h
ours
of o
pera
tion.
LED
Lam
ps w
ith
Inte
rnal
Driv
er u
sing
Lin
e Vo
ltage
to to
mbs
tone
s (U
L Ty
pe B
) are
NO
T el
igib
le, s
ee m
easu
re c
ode
81F.
81E
LED
4 ft
. Lam
p St
yle
Ret
rofit
-Kits
with
Ext
erna
l Driv
er (U
L Ty
pe C
) are
re
quire
d to
be
liste
d by
the
Des
ignL
ight
s C
onso
rtium
® a
nd m
ust m
eet D
LC
tech
nica
l req
uire
men
ts #
17.
Min
imum
of 4
,000
ann
ual h
ours
of o
pera
tion.
LE
D 4
ft. L
inea
r Rep
lace
men
t Lam
ps (U
L Ty
pe A
) and
Lam
ps w
ith
Inte
rnal
Driv
er u
sing
Lin
e Vo
ltage
to s
ocke
ts (U
L Ty
pe B
) are
NO
T el
igib
le,
see
mea
sure
co
des
81C
or
81
F.
12
Type
A&
C
81D
LED
4 ft
. Lam
p St
yle
Ret
rofit
-Kits
with
Ext
erna
l Driv
er (U
L Ty
pe C
) are
re
quire
d to
be
liste
d by
the
Des
ignL
ight
s C
onso
rtium
® a
nd m
ust m
eet D
LC
tech
nica
l req
uire
men
ts #
17.
Min
imum
of 3
,100
ann
ual h
ours
of o
pera
tion.
LE
D 4
ft. L
inea
r Rep
lace
men
t Lam
ps (U
L Ty
pe A
) and
Lam
ps w
ith
Inte
rnal
Driv
er u
sing
Lin
e Vo
ltage
to s
ocke
ts (U
L Ty
pe B
) are
NO
T el
igib
le,
see
mea
sure
co
des
81C
or
81
F.
12 12
LED
Line
aran
dU
-Ben
dR
epla
cem
ent
Lam
ps(U
LTy
peA)
and
Exte
rnal
Driv
erLa
mp
Styl
eR
etro
fit-K
it(U
LTy
peC
)
LED
4ft.
Exte
rnal
Driv
erLa
mp
Styl
eR
etro
fit-
Kit(
UL
Type
C)
LED
4ft.
Exte
rnal
Driv
erLa
mp
Styl
eR
etro
fit-
Kit(
UL
Type
C)
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6
/201
7P
age
4 of
12
1-80
0-78
7-17
06 /
Fa
x: 1
-315
-460
-980
3
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
-
Measu
re
Co
de
Measu
reD
escri
pti
on
Per
Un
it
Incen
tive
Eli
gib
ilit
yC
rite
ria
Min
Watt
s
Saved
Imag
e
$3(p
erla
mp)
$4(p
erla
mp)
81M
LED
Mog
elSc
rew
Base
(E39
)Rep
lace
men
tfo
rHID
Lam
ps$3
0LE
DM
ogel
Scre
wBa
se(E
39)R
epla
cem
entf
orH
IDLa
mps
are
requ
ired
tobe
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eett
echn
ical
requ
irem
ents
#20,
#21,
#22,
#23,
or#2
4.40
81M
HLE
DM
ogel
Scre
wBa
sed
(E39
)R
epla
cem
entf
orH
IDLa
mps
-Hig
hO
utpu
t$7
0LE
D M
ogel
Scr
ew B
ase
(E39
) Rep
lace
men
t for
HID
Lam
ps a
re re
quire
d to
be li
sted
by
the
Des
ignL
ight
s C
onso
rtium
® a
nd m
ust m
eet t
echn
ical
re
quire
men
ts #
21, #
22, #
23, o
r #24
.11
0
71In
tegr
alC
eram
icM
etal
Hal
ide
PAR
Rep
lace
men
tLam
p$1
0El
igib
leIn
tegr
alC
eram
icM
etal
Hal
ide
PAR
repl
acem
entl
amps
shal
lnot
exce
ed25
WPA
R38
lam
por
sim
ilar.
27
25LE
Dor
LEC
(Ele
ctro
lum
ines
cenc
e)Ex
itFi
xtur
es$1
0
Allu
nits
shal
lcom
ply
with
appl
icab
leco
des
and
stan
dard
s;in
clud
ing
(but
not
limite
dto
)Fed
eral
/Sta
te/L
ocal
build
ing,
fire,
and
elec
trica
lcod
esan
dm
ayre
quire
desi
gnat
edeg
ress
light
ing
toco
mpl
yw
ithsu
chco
des.
Ex
its
ign
retr
ofi
tk
its
are
no
te
lig
ible
.
15
Ove
rall
fixtu
reef
ficie
ncy
mus
tbe
>:
•83
%fo
r2x4
pris
mat
icle
nsed
fixtu
rew
ithtw
oT-
8or
T-5
lam
ps;
•75
%fo
r2x2
pris
mat
icle
nsed
fixtu
rew
ithtw
oT-
8or
T-5
lam
ps(2
8WR
educ
edw
atta
gebi
axla
mps
are
elig
ible
).O
vera
llfix
ture
effic
ienc
ym
ustb
e>
:•
80%
for2
x4fix
ture
with
para
bolic
louv
er(2
"to
3"de
epce
lls)w
ithtw
oT-
8or
T-5
lam
ps;
•80
%fo
r2x2
fixtu
res
with
para
bolic
louv
er(2
"to
3"de
epce
lls)w
ithtw
oT-
8or
T-5
lam
ps.(
28W
Red
uced
wat
tage
biax
lam
psar
eel
igib
le).
Ove
rall
fixtu
reef
ficie
ncy
mus
tbe
>:
•75
%fo
r2x4
rece
ssed
indi
rect
/dire
ctfix
ture
with
twoT
-8or
T-5
lam
ps;
•70
%fo
r2x2
rece
ssed
indi
rect
/dire
ctfix
ture
with
two
T-8,
T-5,
orT-
5H
Ola
mps
.(28
WR
educ
edw
atta
gebi
axla
mps
are
elig
ible
).
Tab
le1A
.2:
Com
mer
cial
/In
du
stri
alIn
teri
orF
ixtu
reO
pti
ons
81F
LED
Line
aran
dU
-Ben
dR
epla
cem
ent
Lam
psw
ithIn
tern
alD
river
usin
gLi
neVo
ltage
toTo
mbs
tone
s(U
LT
yp
eB
)O
NL
Y
LED
2ft.
,3ft.
,and
4ft.
Line
aran
dU
-Ben
dR
epla
cem
entL
amps
with
line
volta
ge(U
LTy
peB)
are
requ
ired
tobe
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCte
chni
calr
equi
rem
ents
#17,
#18,
or#1
9.Ex
istin
gla
mp
hold
ers
mus
tbe
repl
aced
with
new
assu
pplie
dor
spec
ified
byla
mp
man
ufac
ture
r.Fi
xtur
esbe
ing
retro
fitte
dm
ustb
ecl
early
labe
led
toal
ert
ofal
tera
tions
with
line
volta
geto
lam
pho
lder
.C
opy
ofal
lsaf
ety
train
ing
and/
orin
stru
ctio
nsm
ustb
epr
ovid
ed.
On
ein
ce
nti
ve
pe
rla
mp
.
12
Type
B
81H
LED
2-pi
nor
4-pi
nC
ompa
ctFl
uore
scen
tR
epla
cem
entL
amps
LED
2-pi
nor
4-pi
nC
ompa
ctFl
uore
scen
tRep
lace
men
tLam
ps-v
ertic
leor
horiz
onta
lins
talla
tion
with
inte
gral
driv
er(U
LTy
peA)
are
requ
ired
tobe
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCte
chni
calr
equi
rem
ents
#25
or#2
6.O
ne
inc
en
tive
pe
rla
mp
.
5
Hig
hEf
ficie
ncy
2-la
mp
Pris
mat
icLe
nsed
Fluo
resc
entF
ixtu
res
-2x2
or2x
430
A$2
027
Hig
hEf
ficie
ncy
2-la
mp
Para
bolic
Fluo
resc
entF
ixtu
res
-2x2
or2x
430
B$2
527
Hig
hEf
ficie
ncy
upto
2-la
mp
Rec
esse
dIn
dire
ct/D
irect
Fluo
resc
entF
ixtu
res
-2x2
or2x
430
C$2
527
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6
/201
7
Pag
e 5
of 1
21-
800-
787-
1706
/ F
ax:
1-3
15-4
60-9
803
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
-
Measu
re
Co
de
Measu
reD
escri
pti
on
Per
Un
it
Incen
tive
Eli
gib
ilit
yC
rite
ria
Min
Watt
s
Saved
Imag
eO
vera
llfix
ture
effic
ienc
ym
ustb
e>
:•
83%
for2
x4pr
ism
atic
lens
edfix
ture
with
thre
eT-
8or
T-5
lam
ps;
•75
%fo
r2x4
fixtu
rew
ithpa
rabo
liclo
uver
(2"t
o3"
deep
cells
)with
thre
eT-
8or
T-5
lam
ps;
•70
%fo
r2x4
rece
ssed
indi
rect
fixtu
rew
ithth
ree
T-8
orT-
5la
mps
;E
lig
ible
fix
ture
sa
reli
mit
ed
to3
lam
ps
wit
ha
low
po
we
rb
all
as
tfa
cto
r<
0.8
0.
Ove
rall
fixtu
reef
ficie
ncy
mus
tbe
>:
•80
%fo
r2x4
para
bolic
retro
fitki
tand
adva
nced
glar
ere
duci
ngdi
ffuse
rre
trofit
kitw
ithtw
oT-
8or
T-5
lam
ps;
•80
%fo
r2x2
para
bolic
retro
fitki
tand
adva
nced
glar
ere
duci
ngdi
ffuse
rre
trofit
kitw
ithtw
oT-
8,T
-5,o
rT-5
HO
lam
ps(2
8WR
educ
edw
atta
gebi
axla
mps
are
elig
ible
).O
vera
llfix
ture
effic
ienc
ym
ustb
e>
:•
85%
for2
x4ad
vanc
edgl
are
redu
cing
diffu
serf
ixtu
rew
ithon
eor
two
T-8
orT-
5la
mps
,oro
neT-
5HO
lam
p;•
80%
for1
x4ad
vanc
edgl
are
redu
cing
diffu
serf
ixtu
rew
ithon
eor
two
T-8
orT-
5la
mps
,oro
neT-
5HO
lam
p.•
80%
for2
x2ad
vanc
edgl
are
redu
cing
diffu
serf
ixtu
rew
ithon
eor
two
T-8
orT-
5la
mps
,oro
neT-
5HO
lam
p(2
8WR
educ
edw
atta
gebi
axla
mps
are
elig
ible
).O
vera
llfix
ture
effic
ienc
ym
ustb
e>
:•
85%
forI
ndus
trial
Ref
lect
orfix
ture
with
T-8
orT-
5la
mps
(up
to20
%up
-lig
ht);
•83
%fo
rCom
mer
cial
Gra
deW
rapa
roun
dfix
ture
with
one
ortw
oT-
8or
T-5
lam
ps.
•85
%fo
rref
lect
orki
tsw
ithsp
ecul
aror
sem
i-spe
cula
rref
lect
ors
Ref
lect
orKi
tsfo
rExi
stin
gFi
xtur
esin
clud
es2’
x2’,
and
2’x4
’ref
lect
ortro
ffer
kits
,4’a
nd8’
strip
chan
nel,
and
indu
stria
lref
lect
orki
ts.
Onl
yon
ein
cent
ive
may
beco
unte
dpe
rfix
ture
.Eig
htfo
otan
dm
ultip
lefix
ture
sse
rved
bya
sing
leba
llast
are
only
elig
ible
foro
nein
cent
ive.
56H
igh
Inte
nsity
Fluo
resc
entF
ixtu
res
(HIF
)for
Hig
han
dLo
wBa
yAp
plic
atio
ns(le
ssth
anor
equa
lto
210W
)$3
5
Min
imum
wat
tage
is11
1W
atts
and
Max
imum
wat
tage
is21
0W
atts
.M
inim
umfix
ture
effic
ienc
ym
uste
xcee
d80
%.
Rec
omm
ende
dm
ount
ing
heig
ht>
16fe
etab
ove
the
floor
.H
igh
Inte
nsity
Fluo
resc
entf
ixtu
res
inco
rpor
ate
anu
mbe
rofl
amp
tech
nolo
gies
that
incl
ude
T-8,
T-5,
T-5H
Oan
dco
mpa
ctflu
ores
cent
.Lo
wp
ow
er
ba
lla
sts
are
no
te
lig
ible
.
55
57H
igh
Inte
nsity
Fluo
resc
entF
ixtu
res
(HIF
)for
Hig
han
dLo
wBa
yAp
plic
atio
ns(g
reat
erth
an21
0W)
$50
Min
imum
wat
tage
isgr
eate
rtha
n21
0W
atts
.Min
imum
fixtu
reef
ficie
ncy
mus
tex
ceed
80%
.R
ecom
men
ded
mou
ntin
ghe
ight
>20
feet
abov
eth
eflo
or.H
igh
Inte
nsity
Fluo
resc
entf
ixtu
res
inco
rpor
ate
anu
mbe
rofl
amp
tech
nolo
gies
that
incl
ude
T-8,
T-5,
T-5H
Oan
dco
mpa
ctflu
ores
cent
.Lo
wp
ow
er
ba
lla
sts
are
no
te
lig
ible
.
85
Adva
nced
Rec
esse
dFl
uore
scen
tFix
ture
s-
2x2,
1x4
or2x
434
$30
33
Indu
stria
l/Com
mer
cial
Fluo
resc
entF
ixtu
res
4ft.
and
8ft.
Fixt
ures
41$2
023
Hig
hEf
ficie
ncy
3-la
mp
Fluo
resc
entF
ixtu
res
-2x
431
$20
31
Hig
hEf
ficie
ncy
Rec
esse
dFl
uore
scen
t2-
lam
pR
etro
fitKi
ts-2
x2an
d2x
432
$20
27
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6
/201
7P
age
6 of
12
1-80
0-78
7-17
06 /
Fa
x: 1
-315
-460
-980
3
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
-
Measu
re
Co
de
Measu
reD
escri
pti
on
Per
Un
it
Incen
tive
Eli
gib
ilit
yC
rite
ria
Min
Watt
s
Saved
Imag
e
70C
eram
icM
etal
Hal
ide
Spec
ialty
Ligh
ting
Har
dW
ired
Fixt
ures
with
Elec
troni
cBa
llast
$20
Cer
amic
Met
alH
alid
eSp
ecia
ltyFi
xtur
esm
aybe
track
,rec
esse
dor
surfa
cem
ount
edan
dus
edfo
rhig
hqu
ality
disp
lay
type
light
ing.
Mus
tbe
appr
oved
byU
Lor
sim
ilara
genc
y.55
80LE
DD
own
Ligh
tFix
ture
s-H
ard
Wire
d$5
0El
igib
leD
own
Ligh
tsar
ere
quire
dto
beha
rdw
ired
and
liste
das
aco
mm
erci
alLE
Dpr
oduc
tby
Ener
gySt
ar.
25
84LE
DTr
ack
orM
ono-
Poin
tDire
ctio
nal
Fixt
ures
$15
LED
track
orm
ono-
poin
tdire
ctio
nalf
ixtu
res
mus
tbe
liste
dby
Ener
gySt
aror
the
Des
ignL
ight
sC
onso
rtium
®an
dm
eetD
LCte
chni
calr
equi
rem
ent#
5.45
88A
LED
Inte
rior1
x4,2
x2,a
nd2x
4Pa
nel
Fixt
ures
and
LED
Ret
rofit
Kits
$25
Elig
ible
LED
Inte
rior1
x4,2
x2,a
nd2x
4fix
ture
san
dre
trofit
kits
are
requ
ired
tobe
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCTe
chni
cal
Req
uire
men
ts#7
orfo
rret
rofit
kits
#14.
Mu
st
ha
ve
am
inim
um
of
2,0
00
an
nu
al
ho
urs
of
op
era
tio
n.
44
88B
LED
Inte
rior1
x4,2
x2,a
nd2x
4Pa
nel
Fixt
ures
and
LED
Ret
rofit
Kits
$35
Elig
ible
LED
Inte
rior1
x4,2
x2,a
nd2x
4fix
ture
san
dre
trofit
kits
are
requ
ired
tobe
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCTe
chni
cal
Req
uire
men
ts#7
orfo
rret
rofit
kits
#14.
Mu
st
ha
ve
am
inim
um
of
3,1
00
an
nu
al
ho
urs
of
op
era
tio
n.
60
88C
LED
Inte
rior1
x4,2
x2,a
nd2x
4Pa
nel
Fixt
ures
and
LED
Ret
rofit
Kits
$40
Elig
ible
LED
Inte
rior1
x4,2
x2,a
nd2x
4fix
ture
san
dre
trofit
kits
are
requ
ired
tobe
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCTe
chni
cal
Req
uire
men
ts#7
orfo
rret
rofit
kits
#14.
Mu
st
ha
ve
am
inim
um
of
4,0
00
an
nu
al
ho
urs
of
op
era
tio
n.
50
89LE
DD
irect
Line
arAm
bien
tFix
ture
$15
LED
Dire
ctLi
near
Ambi
entF
ixtu
rem
ustb
elis
ted
byth
eD
esig
nLig
hts
Con
sorti
um®
and
mee
tDLC
tech
nica
lreq
uire
men
t#8.
30
82A
LED
Dis
play
Cas
e:C
oole
r,Fr
eeze
r,or
Ref
riger
ated
Shel
ving
Fixt
ures
–3f
t.&
4ft.
Fixt
ures
$30
Elig
ible
LED
Coo
lera
ndFr
eeze
rCas
efix
ture
sar
ere
quire
dto
belis
ted
byth
eD
esig
nLig
hts
Con
sorti
um®
and
mus
tmee
tDLC
Tech
nica
lReq
uire
men
ts#6
.P
lea
se
sp
ec
ify
qu
an
tity
of
en
da
nd
/or
ce
nte
rm
ou
nt
fix
ture
sin
Ta
ble
2A
.
14
82B
LED
Dis
play
Cas
e:C
oole
r,Fr
eeze
r,or
Ref
riger
ated
Shel
ving
Fixt
ures
–5f
t.&
6ft.
Fixt
ure
$50
Elig
ible
LED
Coo
lera
ndFr
eeze
rCas
efix
ture
sar
ere
quire
dto
belis
ted
byth
eD
esig
nLig
hts
Con
sorti
um®
and
mus
tmee
tDLC
Tech
nica
lReq
uire
men
ts#6
.P
lea
se
sp
ec
ify
qu
an
tity
of
en
da
nd
/or
ce
nte
rm
ou
nt
fix
ture
sin
Ta
ble
2A
.
23
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6/2
017
Pag
e 7
of 1
21-
800-
787-
1706
/ F
ax:
1-3
15-4
60-9
803
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
-
Measu
re
Co
de
Measu
reD
escri
pti
on
Per
Un
it
Incen
tive
Eli
gib
ilit
yC
rite
ria
Min
Watt
s
Saved
Imag
e
86A
LED
Inte
riorH
igh
Bay
&Lo
wBa
yFi
xtur
esor
Ret
rofit
Kits
(<9,
500
lum
ens)
$35
Elig
ible
LED
inte
riorh
igh
bay
&lo
wba
yfix
ture
sor
retro
fitki
tsar
ere
quire
dto
belis
ted
byth
eD
esig
nLig
hts
Con
sorti
um®
and
mus
tmee
tDLC
Tech
nica
lR
equi
rem
ents
#9,o
rifa
retro
fitki
t#16
.In
teg
ral
ba
lla
st
sc
rew
-ba
se
dla
mp
retr
ofi
tp
rod
uc
tsa
reN
OT
eli
gib
lefo
rth
isin
ce
nti
ve
,s
ee
me
as
ure
co
de
81
Mo
r8
1M
H.
75
86B
LED
Inte
riorH
igh
Bay
Fixt
ures
orR
etro
fitKi
ts(9
,501
-19,
999
lum
ens)
$115
Elig
ible
LED
inte
riorh
igh
bay
fixtu
res
orre
trofit
kits
are
requ
ired
tobe
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCTe
chni
cal
Req
uire
men
ts#9
,ori
fare
trofit
kit#
16.
Inte
gra
lb
all
as
ts
cre
w-b
as
ed
lam
p
retr
ofi
tp
rod
uc
tsa
reN
OT
eli
gib
lefo
rth
isin
ce
nti
ve
,s
ee
me
as
ure
co
de
81
Mo
r8
1M
H.
210
86C
LE
D I
nte
rio
r H
igh
Ba
y F
ixtu
res (
≥ 2
0,0
00
lu
men
s)$1
75
Elig
ible
LED
inte
riorh
igh
bay
fixtu
res
are
requ
ired
tobe
liste
dby
theD
esig
nLig
hts
Con
sorti
um®
and
mus
tmee
tDLC
Tech
nica
lReq
uire
men
ts#9
.R
etr
ofi
tk
its
are
NO
Te
lig
ible
un
de
rth
ism
ea
su
rec
od
e.
Ple
as
es
ee
86
Bfo
rre
tro
fit
eli
gib
ilit
y.
290
Ove
rall
fixtu
reef
ficie
ncy
mus
tbe
>:
•70
%fo
rVap
orTi
ghtf
luor
esce
ntfix
ture
with
one
ortw
oT-
8,T-
5,T-
8HO
,T-
5HO
or3-
T8la
mps
.Ty
pica
llyin
stal
led
inga
rage
,war
ehou
se,f
ood
prep
,and
othe
rind
ustri
alap
plic
atio
ns.
Elig
ible
fixtu
res
mus
tbe
inst
alle
din
acl
ean
room
rate
den
viro
nmen
t.O
vera
llfix
ture
effic
ienc
ym
ustb
e>
:•
75%
forC
lean
Roo
mflu
ores
cent
fixtu
rew
ithup
toth
ree
T-8
orT-
5la
mps
.
92LE
DVa
porT
ight
Fixt
ures
-4ft.
and
8ft.
Fixt
ures
$20
Elig
ible
LED
vapo
rtig
htfix
ture
sar
ere
quire
dto
belis
ted
byth
eD
esig
nLig
hts
Con
sorti
um®
and
mus
tmee
tDLC
Tech
nica
lReq
uire
men
ts#8
.45
Elig
ible
LED
Fixt
ures
fors
urfa
ce,r
egre
ssed
,can
opy
mou
nted
vapo
rtig
htar
ere
quire
dto
belis
ted
byth
eD
esig
nLig
hts
Con
sorti
um®
and
mus
tmee
tDLC
Tech
nica
lReq
uire
men
ts#1
,#2,
#3or
#4.
Mu
st
ha
ve
8,7
60
an
nu
al
ho
urs
of
op
era
tio
n.
LE
DR
etr
ofi
tk
its
are
no
te
lig
ible
un
de
rth
ism
ea
su
rec
od
e.
Ple
as
es
ee
83
Bfo
rR
etr
ofi
tK
ite
lig
ibil
ity.
83B
LED
Exte
riorF
ixtu
res
and
Ret
rofit
Kits
-G
arag
e&
Can
opy
Du
sk
toD
aw
nO
pera
tio
n
$100
Elig
ible
LED
Fixt
ures
orR
etro
fitKi
tsfo
rsur
face
,reg
ress
ed,c
anop
ym
ount
edva
port
ight
are
requ
ired
tobe
liste
dby
theD
esig
nLig
hts
Con
sorti
um®
and
mus
tmee
tDLC
Tech
nica
lReq
uire
men
ts#1
,#2,
#3,o
r#4,
orfo
rret
rofit
kits
#10,
#11,
#12,
or#1
3.M
us
th
ave
am
inim
um
of
4,3
80
an
nu
al
ho
urs
of
op
era
tio
n.
95
Vapo
rTig
htFl
uore
scen
tFix
ture
s-4
ft.an
d8
ft.Fi
xtur
es43
$20
45
Cle
anR
oom
Rat
edFl
uore
scen
tFix
ture
s-
1x4
or2x
444
$30
60
LED
Exte
riorF
ixtu
res
-Gar
age
&C
anop
y24/7
Op
era
tio
n83
A$1
5060
Tab
le1A
.3:
Ou
tdoo
r/
Ext
erio
r/
Har
shE
nvi
ron
men
tF
ixtu
reO
pti
ons
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6
/201
7P
age
8 of
12
1-80
0-78
7-17
06 /
Fa
x: 1
-315
-460
-980
3
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
-
Measu
re
Co
de
Measu
reD
escri
pti
on
Per
Un
it
Incen
tive
Eli
gib
ilit
yC
rite
ria
Min
Watt
s
Saved
Imag
e
85A
LED
Exte
riorW
all/P
ole/
Arm
Mou
nted
Area
and
Floo
dFi
xtur
esan
dR
etro
fitKi
ts$2
5
Elig
ible
LED
exte
riorw
all/p
ole/
arm
mou
nted
area
orflo
odfix
ture
sor
retro
fitki
tsar
ere
quire
dto
belis
ted
byth
eDes
ignL
ight
sC
onso
rtium
®an
dm
ustm
eet
DLC
Tech
nica
lReq
uire
men
ts#1
,#2,
#3,o
r#4
orfo
rret
rofit
kits
#10,
#11,
#12,
or#1
3.M
us
th
ave
am
inim
um
of
2,0
00
an
nu
al
ho
urs
of
op
era
tio
n.
73
87A
LED
Exte
riorW
all/P
ole/
Arm
Mou
nted
Area
and
Floo
dFi
xtur
esan
dR
etro
fitKi
ts-L
ow,
Med
ium
,&H
igh
Out
put
Du
sk
toD
aw
nO
pera
tio
n
$75
Elig
ible
LED
wal
l/pol
e/ar
mm
ount
edar
eaan
dflo
odfix
ture
sar
ere
quire
dto
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCTe
chni
cal
Req
uire
men
ts#1
,#2,
#3,o
r#4
orfo
rRet
rofit
Kits
#10,
#11,
#12,
or#1
3.M
us
th
ave
am
inim
um
of
43
80
an
nu
al
ho
urs
of
op
era
tio
n.
128
87B
LED
Ext
erio
r Wal
l/Pol
e/A
rm M
ount
ed A
rea
and
Floo
d Fi
xtur
es a
nd R
etro
fit K
its -
Med
ium
& H
igh
Out
put
Dus
k to
Daw
n O
pera
tio
n
$145
Elig
ible
LED
wal
l/pol
e/ar
mm
ount
edar
eaan
dflo
odfix
ture
sar
ere
quire
dto
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCte
chni
cal
Req
uire
men
ts#2
,#3,
or$4
.R
etro
fitKi
tsm
ustm
eetD
LCTe
chni
cal
Req
uire
men
ts#1
1,#1
2,or
#13.
Mu
st
ha
ve
am
inim
um
of
43
80
an
nu
al
ho
urs
of
op
era
tio
n.
140
87C
LED
Exte
riorW
all/P
ole/
Arm
Mou
nted
Area
and
Floo
dFi
xtur
es-H
igh
orVe
ryH
igh
Out
put
Du
sk
toD
aw
nO
pera
tio
n
$265
Elig
ible
LED
wal
l/pol
e/ar
mm
ount
edar
eaan
dflo
odFi
xtur
esar
ere
quire
dto
liste
dby
the
Des
ignL
ight
sC
onso
rtium
®an
dm
ustm
eetD
LCte
chni
cal
Req
uire
men
ts#3
or#4
.L
ED
Re
tro
fit
kit
sa
ren
ot
eli
gib
leu
nd
er
this
me
as
ure
co
de
.P
lea
se
se
e8
7B
for
Re
tro
fit
Kit
eli
gib
ilit
y.
Mu
st
ha
ve
a
min
imu
mo
f4
38
0a
nn
ua
lh
ou
rso
fo
pe
rati
on
.
250
No
tes:
ww
w.c
ee1.
org/
qual
ifyin
gT8
lam
psw
ww
.ene
rgys
tar.g
ov/L
ED
•E
nerg
y S
tar®
qua
lifie
d LE
D p
rodu
cts
listin
gs a
nd te
chni
cal r
equi
rem
ents
can
be
foun
d at
:\
•D
esig
nLig
hts
Con
sorti
um®
(DLC
) qua
lifie
d LE
D p
rodu
cts
listin
g an
d te
chni
cal r
equi
rem
ents
can
be
foun
d at
: w
ww
.des
ignl
ight
s.or
ght
tps:
//ww
w.li
ghtin
gdes
ignl
ab.c
om/le
d-qp
l
Itis
the
resp
onsi
bilit
yof
the
light
ing
inst
alle
rsto
mee
tcur
rent
Illum
inat
ing
Eng
inee
ring
Soc
iety
stan
dard
sfo
rlig
htle
vels
,lig
htdi
strib
utio
n,un
iform
ity,a
ndlig
htin
gqu
ality
fora
llin
stal
latio
ns.
Nat
iona
lGrid
does
notw
arra
ntor
acce
ptan
ylia
bilit
yw
hats
oeve
rfor
LED
2ft.
or4f
t.Li
near
Rep
lace
men
tLam
psor
Ret
rofit
Kits
that
rece
ive
ince
ntiv
esth
roug
hou
rene
rgy
effic
ieny
prog
ram
s.C
usto
mer
sar
ere
spon
sibl
efo
rthe
prop
erm
odifi
catio
nan
din
stal
latio
nof
LED
2ft.
and
4ft.
Line
arR
epla
cem
entL
amps
orR
etro
fitK
itsin
exis
ting
fixtu
res
inac
cord
ance
with
man
ufac
ture
r’sin
stru
ctio
ns.
Cus
tom
ers
shou
ldbe
awar
eth
atfix
ture
mod
ifica
tions
may
void
war
rant
y.C
usto
mer
sar
ere
spon
sibl
efo
rpro
perl
abel
ing
ofal
lmod
ified
fixtu
res.
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6
/201
7P
age
9 of
12
1-80
0-78
7-17
06 /
Fa
x: 1
-315
-460
-980
3
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
•A
ll pr
opos
ed F
luor
esce
nt F
ixtu
res
mus
t be
equi
pped
with
new
T-8
or T
-5 la
mps
and
new
ele
ctro
nic
balla
sts
that
mee
t cur
rent
fede
ral e
nerg
y co
nser
vatio
n st
anda
rds.
All
4 ft.
fluo
resc
ent T
-8 la
mps
mus
t mee
t or
exc
eed
the
Con
sorti
um fo
r Ene
rgy
Effi
cien
cy’s
(CE
E) T
-8 re
plac
emen
t lam
p sp
ecifi
catio
n. F
or d
etai
led
elig
ibili
ty re
quire
men
ts a
nd a
list
of q
ualif
ying
lam
ps, p
leas
e lo
g on
to C
EE
’s w
eb s
ite a
t:
• F
acili
ty li
ghtin
g m
ust a
vera
ge a
min
imum
of 2
,000
hou
rs p
er y
ear,
exce
pt M
unic
ipal
Fac
ilitie
s w
hich
mus
t ave
rage
a m
inim
um o
f 1,0
00 h
ours
• L
ED
pro
duct
s no
t fou
nd o
n E
nerg
y S
tar o
r DLC
qua
lifie
d pr
oduc
ts li
sts
may
be
elig
ible
for i
ncen
tives
if fo
und
on L
ight
ing
Des
ign
Labs
(LD
L) q
ualif
ied
prod
ucts
list
whi
ch c
an b
e fo
und
at:
-
Ta
ble
1B
:L
igh
tin
gC
on
tro
lsE
lig
ibil
ity
an
dIn
ce
nti
ve
Le
ve
ls(
Co
mp
lete
Ta
ble
2B
for
Lig
hti
ng
Co
ntr
ol
Ins
tall
ati
on
s)
Measu
re
Co
de
Measu
reD
escri
pti
on
Per
Un
it
Incen
tive
Eli
gib
ilit
yC
rite
ria
Min
Watt
s
Co
ntr
oll
ed
Imag
e
61R
emot
eM
ount
edO
ccup
ancy
Sen
sor
$20
Cei
ling
Mou
nted
Con
trol.
Com
ply
with
man
ufac
ture
rcov
erag
ere
com
men
datio
ns.
Ma
nu
al
"ON
"o
ve
rrid
es
are
no
te
lig
ible
.60
$15
25(p
erfix
ture
)(p
erfix
ture
)
$25
25(p
erfix
ture
)(p
erfix
ture
)
64W
allM
ount
edO
ccup
ancy
Sen
sor
$10
Occ
upan
cyse
nsor
mus
tope
rate
asA
utom
atic
On
and
Off.
Sen
sors
mus
tbe
wal
lmou
nted
devi
ces
only
.V
acan
cyse
nsor
sw
ithM
anua
lO
n,A
utom
atic
OFF
optio
nsar
eal
low
ed.
Ma
nu
al
"ON
"o
ve
rrid
es
are
no
te
lig
ible
.
40
65P
hoto
cell
Sen
sor
-Ext
erio
rLig
htin
gap
plic
atio
nsop
erat
ing
24/7
$20
Pho
toce
llse
nsor
orha
rd-w
ired
astro
nom
ical
timer
cont
rolle
rfor
light
ing
syst
ems
that
oper
ate
24ho
urs
perd
ay,7
days
perw
eek
(8,7
60an
nual
hour
s).
50
$25
65(p
erfix
ture
)(p
erfix
ture
)
62D
aylig
htan
d/or
Occ
upan
cyD
imm
ing
Sys
tem
Bal
last
orLE
Ddr
iver
sm
ustb
eau
tom
atic
ally
cont
rolle
dba
sed
onda
ylig
htor
occu
panc
yle
vels
.
63In
tegr
alFi
xtur
eM
ount
edD
ualS
enso
rs&
Con
trolle
rs
Inte
gral
fixtu
rem
ount
eddu
alse
nsor
with
mot
ion
and
phot
ocel
l/am
bien
tlig
htse
nsor
.S
yste
mto
cont
rolm
otio
nre
spon
sean
dill
umin
atio
nle
vels
.O
nly
one
ince
ntiv
epe
rfix
ture
.
Fluo
resc
entb
alla
sts
orLE
Ddr
iver
sm
ustb
eau
tom
atic
ally
cont
rolle
dba
sed
onoc
cupa
ncy.
Sen
sors
mus
tbe
inte
gral
(bui
ltin
to)o
rpe
rman
ently
atta
ched
toea
chfix
ture
.M
an
ua
l"O
N"
or
ove
rrid
es
are
no
te
lig
ible
.
Occ
upan
cyS
enso
rfor
Hig
hB
ayFi
xtur
es68
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6
/201
7P
age
10 o
f 12
1-80
0-78
7-17
06 /
Fa
x: 1
-315
-460
-980
3
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
-
Ta
ble
2A
:L
igh
tin
gS
ys
tem
sIn
ve
nto
ryW
ork
sh
ee
t
Faci
lity
Nam
eB
uil
din
gS
qu
are
Fo
otg
e:
Ove
rall
Bldg
Sq.F
t.A
nn
ua
lE
ne
rgy
Us
ag
e:
add
12m
onth
skW
hus
age
Lin
e
Ite
m
Inte
rio
ro
r
Ex
teri
or
(Io
rE
)
Co
nd
itio
ne
d
Sp
ac
e(Y
es
,N
o
or
Re
frig
era
ted
)L
oc
ati
on
An
nu
al
Op
era
tin
g
Ho
urs
**F
ixtu
re/L
am
p/B
all
as
tD
es
cri
pti
on
Ex
isti
ng
Qu
an
tity
NY
De
vic
e
Co
de
*
Ex
isti
ng
Wa
tts
pe
r
Fix
ture
/De
vic
eM
ea
su
reC
od
eF
ixtu
re/L
am
p/B
all
as
tD
es
cri
pti
on
Pro
po
se
d
Qu
an
tity
NY
De
vic
e
Co
de
*
Pro
po
se
dW
att
s
pe
r
Fix
ture
/De
vic
e
Pe
rF
ixtu
re
Inc
en
tive
To
tal
Lig
hti
ng
Inc
en
tive
Ex.
IY
inte
rioro
ffice
spac
e28
882x
4le
nsed
troffe
r50
F44I
LL11
2
88A
-LE
DIn
terio
r1x4
,2x2
,and
2x4
Pan
elFi
xtur
esan
dLE
DR
etro
fitK
itsLE
Dtro
ffer
50FL
ED
038
3825
1,25
0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Ins
tall
ati
on
Sit
e:
Ex
isti
ng
Lig
hti
ng
Pro
po
se
dL
igh
tin
g
Ligh
ting
Sys
tem
s C
ontro
ls 2
017
Ret
rofit
Pro
gram
UN
Y
Rev
. 1/6
/201
7P
age
11 o
f 12
1-80
0-78
7-17
06 /
Fa
x: 1
-315
-460
-980
3
Eff
icie
ncy
@n
aio
nal
gri
d.c
om
/ w
ww
.ng
rid
.co
m/u
nyb
iz
Clic
k th
is b
utto
n to
acc
ess
the
exce
l file
of t
he li
ghtin
g an
d co
ntro
ls m
easu
res
and
syst
em in
vent
ory
wor
kshe
ets.
Pl
ease
incl
ude
this
exc
el fi
le a
s pa
rt o
f you
r com
plet
ed p
acka
ge s
ubm
itted
to N
atio
nal G
rid.
If yo
u do
not
hav
e ac
cess
to E
xcel
or u
se a
ver
sion
bef
ore
2010
ple
ase
fill i
n th
e w
orks
heet
(s) b
elow
and
sub
mit
to N
atio
nal G
rid.
Sam
ple:
Ref
er to
Not
e an
d Li
nk A
bove
Note:
Sub
mis
sion
s w
ill b
e ve
rifie
d fo
r acc
urac
y an
d m
ay b
e co
rrec
ted
to m
eet p
rogr
am re
quire
men
ts*
Ref
er to
the
NY
Dev
ice
Cod
es &
Rat
ed S
yste
m W
atta
ge T
able
foun
d on
our
web
site
or i
n th
e ta
b of
the
exce
l file
of t
his
wor
kshe
et**
Fac
ility
ligh
ting
mus
t ave
rage
a m
inim
um o
f 2,0
00 h
ours
ann
ually
, exc
ept M
unic
ipal
Fac
ilitie
s w
hich
mus
t ave
rage
a m
inim
um o
f 1,0
00 h
ours
ann
ually
Lighting Measures-1A
Table 1A: Lighting Systems Eligibility and Incentive Levels ( Complete Table 2A for Lighting System Installations)
Measure CodeMeasure DescriptionPer Unit IncentiveEligibility CriteriaMin Watts SavedImage
Table 1A.1: Re-lamp & Re-ballast Replacement Options
10Fluorescent Reduced Wattage T-8 or T-5 Re-lamp and Re-ballast $10Re-lamp/re-ballast of existing fixtures with T-8 or T-5 lamps, each fixture is composed of ballast and 1, 2, 3 or 4 lamps. Only one incentive may be counted per fixture. Multiple fixtures served by a single ballast are only eligible for one incentive.11
12Fluorescent Reduced Wattage T-8 or T-5 Re-lamp and Re-ballast $15Re-lamp/re-ballast of existing fixtures with the opportunity for increased savings of more than 23 watts. Consider using reduced wattage (25W and 28W) T-8 lamps.23
81AIntegral LED Screw-in and Pin Based Directional Replacement Lamps$5Eligible LED screw-in and pin based directional integral replacement lamps include: MR16, PAR16, and PAR20, A-line, candle, and decorative globe lamps. Please check with your National Grid representative for eligibility of other omnidirectional and decorative lamp types. Required to be listed by Energy Star.12
81BIntegral LED screw-in Directional Replacement Lamps – PAR and Screw Base LED Down Light Retrofit Kits$15Eligible LED screw-in directional integral replacement lamps include: PAR30, BR30, and PAR38. Also Eligible; Screw Base LED Down Light Retrofit Kits. Required to be listed by Energy Star.25
81CLED Linear and U-Bend Replacement Lamps (UL Type A) and External Driver Lamp Style Retrofit-Kit (UL Type C)$4LED 2 ft., 3 ft., and 4 ft. Linear and U-Bend Replacement Lamps (UL Type A) and Lamp Style Retrofit-Kits (UL Type C) are required to be listed by the DesignLights Consortium® and must meet DLC technical requirements #17, #18, or #19. Minimum of 2,000 annual hours of operation. LED Lamps with Internal Driver using Line Voltage to tombstones (UL Type B) are NOT eligible, see measure code 81F. 12Type A & C
(per lamp)
81DLED 4 ft. External Driver Lamp Style Retrofit-Kit (UL Type C)$6LED 4 ft. Lamp Style Retrofit-Kits with External Driver (UL Type C) are required to be listed by the DesignLights Consortium® and must meet DLC technical requirements #17. Minimum of 3,100 annual hours of operation. LED 4 ft. Linear Replacement Lamps (UL Type A) and Lamps with Internal Driver using Line Voltage to sockets (UL Type B) are NOT eligible, see measure codes 81C or 81F. 12
(per lamp)
81ELED 4 ft. External Driver Lamp Style Retrofit-Kit (UL Type C)$8LED 4 ft. Lamp Style Retrofit-Kits with External Driver (UL Type C) are required to be listed by the DesignLights Consortium® and must meet DLC technical requirements #17. Minimum of 4,000 annual hours of operation. LED 4 ft. Linear Replacement Lamps (UL Type A) and Lamps with Internal Driver using Line Voltage to sockets (UL Type B) are NOT eligible, see measure codes 81c or 81F. 12
(per lamp)
81FLED Linear and U-Bend Replacement Lamps with Internal Driver using Line Voltage to Tombstones (UL Type B) ONLY$3LED 2 ft., 3 ft., and 4 ft. Linear and U-Bend Replacement Lamps with line voltage (UL Type B) are required to be listed by the DesignLights Consortium® and must meet DLC technical requirements #17, #18, or #19. Existing lamp holders must be replaced with new as supplied or specified by lamp manufacturer. Fixtures being retrofitted must be clearly labeled to alert of alterations with line voltage to lamp holder. Copy of all safety training and/or instructions must be provided. One incentive per lamp.12Type B
(per lamp)
81HLED 2-pin or 4-pin Compact Fluorescent Replacement Lamps$4LED 2-pin or 4-pin Compact Fluorescent Replacement Lamps - vertical or horizontal installation with integral driver (UL Type A) are required to be listed by the DesignLights Consortium® and must meet DLC technical requirements #25 or #26. One incentive per lamp.5
(per lamp)
81MLED Mogel Screw Base (E39) Replacement for HID Lamps$30LED Mogel Screw Base (E39) Replacement for HID Lamps are required to be listed by the DesignLights Consortium® and must meet technical requirements #20, #21, #22, #23, or #24. 40
81MHLED Mogel Screw Based (E39) Replacement for HID Lamps - High Output$70LED Mogel Screw Base (E39) Replacement for HID Lamps are required to be listed by the DesignLights Consortium® and must meet technical requirements #21, #22, #23, or #24. 110
71Integral Ceramic Metal Halide PAR Replacement Lamp $10Eligible Integral Ceramic Metal Halide PAR replacement lamps shall not exceed 25W PAR38 lamp or similar.27
Table 1A.2: Commercial/Industrial Interior Fixture Options
25LED or LEC (Electroluminescence) Exit Fixtures$10All units shall comply with applicable codes and standards; including (but not limited to) Federal/State/Local building, fire, and electrical codes and may require designated egress lighting to comply with such codes. Exit sign retrofit kits are not eligible.15
30AHigh Efficiency 2-lamp Prismatic Lensed Fluorescent Fixtures - 2x2 or 2x4$20Overall fixture efficiency must be > : 27
• 83% for 2x4 prismatic lensed fixture with two T-8 or T-5 lamps;
• 75% for 2x2 prismatic lensed fixture with two T-8 or T-5 lamps (28W Reduced wattage biax lamps are eligible).
30BHigh Efficiency 2-lamp Parabolic Fluorescent Fixtures - 2x2 or 2x4$25Overall fixture efficiency must be > : 27
• 80% for 2x4 fixture with parabolic louver (2" to 3" deep cells) with two T-8 or T-5 lamps;
• 80% for 2x2 fixtures with parabolic louver (2" to 3" deep cells) with two T-8 or T-5 lamps. (28W Reduced wattage biax lamps are eligible).
30CHigh Efficiency up to 2-lamp Recessed Indirect/Direct Fluorescent Fixtures - 2x2 or 2x4$25Overall fixture efficiency must be > : 27
• 75% for 2x4 recessed indirect/direct fixture with twoT-8 or T-5 lamps;
• 70% for 2x2 recessed indirect/direct fixture with two T-8, T-5, or T-5 HO lamps. (28W Reduced wattage biax lamps are eligible).
31High Efficiency 3-lamp Fluorescent Fixtures - 2x4$20Overall fixture efficiency must be > : 31
• 83% for 2x4 prismatic lensed fixture with three T-8 or T-5 lamps;
• 75% for 2x4 fixture with parabolic louver (2" to 3" deep cells) with three T-8 or T-5 lamps;
• 70% for 2x4 recessed indirect fixture with three T-8 or T-5 lamps;
Eligible fixtures are limited to 3 lamps with a low power ballast factor < 0.80.
32High Efficiency Recessed Fluorescent 2-lamp Retrofit Kits - 2x2 and 2x4$20Overall fixture efficiency must be > : 27
• 80% for 2x4 parabolic retrofit kit and advanced glare reducing diffuser retrofit kit with two T-8 or T-5 lamps;
• 80% for 2x2 parabolic retrofit kit and advanced glare reducing diffuser retrofit kit with two T-8 ,T-5, or T-5 HO lamps (28W Reduced wattage biax lamps are eligible).
34Advanced Recessed Fluorescent Fixtures - 2x2, 1x4 or 2x4$30Overall fixture efficiency must be > : 33
• 85% for 2x4 advanced glare reducing diffuser fixture with one or two T-8 or T-5 lamps, or one T-5HO lamp;
• 80% for 1x4 advanced glare reducing diffuser fixture with one or two T-8 or T-5 lamps, or one T-5HO lamp.
• 80% for 2x2 advanced glare reducing diffuser fixture with one or two T-8 or T-5 lamps, or one T-5HO lamp (28W Reduced wattage biax lamps are eligible).
41Industrial/Commercial Fluorescent Fixtures 4 ft. and 8 ft. Fixtures$20Overall fixture efficiency must be > : 23
• 85% for Industrial Reflector fixture with T-8 or T-5 lamps (up to 20% up-light);
• 83% for Commercial Grade Wraparound fixture with one or two T-8 or T-5 lamps.
• 85% for reflector kits with specular or semi-specular reflectors
Reflector Kits for Existing Fixtures includes 2’x2’, and 2’x4’ reflector troffer kits, 4’and 8’strip channel, and industrial reflector kits.
Only one incentive may be counted per fixture. Eight foot and multiple fixtures served by a single ballast are only eligible for one incentive.
56High Intensity Fluorescent Fixtures (HIF) for High and Low Bay Applications (less than or equal to 210W)$35Minimum wattage is 111 Watts and Maximum wattage is 210 Watts. Minimum fixture efficiency must exceed 80%. Recommended mounting height > 16 feet above the floor. High Intensity Fluorescent fixtures incorporate a number of lamp technologies that include T-8, T-5, T-5HO and compact fluorescent. Low power ballasts are not eligible.55
57High Intensity Fluorescent Fixtures (HIF) for High and Low Bay Applications (greater than 210W)$50Minimum wattage is greater than 210 Watts. Minimum fixture efficiency must exceed 80%. Recommended mounting height > 20 feet above the floor. High Intensity Fluorescent fixtures incorporate a number of lamp technologies that include T-8, T-5, T-5HO and compact fluorescent. Low power ballasts are not eligible.85
70Ceramic Metal Halide Specialty Lighting Hard Wired Fixtures with Electronic Ballast $20Ceramic Metal Halide Specialty Fixtures may be track, recessed or surface mounted and used for high quality display type lighting. Must be approved by UL or similar agency.55
80LED Down Light Fixtures - Hard Wired$50Eligible Down Lights are required to be hardwired and listed as a commercial LED product by Energy Star.25
84LED Track or Mono-Point Directional Fixtures$15LED track or mono-point directional fixtures must be listed by Energy Star or the DesignLights Consortium® and meet DLC technical requirement #5.45
88ALED Interior 1x4, 2x2, and 2x4 Panel Fixtures and LED Retrofit Kits$25Eligible LED Interior 1x4, 2x2, and 2x4 fixtures and retrofit kits are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #7 or for retrofit kits #14. Must have a minimum of 2,000 annual hours of operation.44
88BLED Interior 1x4, 2x2, and 2x4 Panel Fixtures and LED Retrofit Kits$35Eligible LED Interior 1x4, 2x2, and 2x4 fixtures and retrofit kits are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #7 or for retrofit kits #14. Must have a minimum of 3,100 annual hours of operation.60
88CLED Interior 1x4, 2x2, and 2x4 Panel Fixtures and LED Retrofit Kits$40Eligible LED Interior 1x4, 2x2, and 2x4 fixtures and retrofit kits are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #7 or for retrofit kits #14. Must have a minimum of 4,000 annual hours of operation.50
89LED Direct Linear Ambient Fixture$15LED Direct Linear Ambient Fixture must be listed by the DesignLights Consortium® and meet DLC technical requirement #8. 30
82ALED Display Case: Cooler, Freezer, or Refrigerated Shelving Fixtures – 3ft. & 4ft. Fixtures$30Eligible LED Cooler and Freezer Case fixtures are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #6. Please specify quantity of end and/or center mount fixtures in Table 2A.14
82BLED Display Case: Cooler, Freezer, or Refrigerated Shelving Fixtures – 5ft. & 6ft. Fixture$50Eligible LED Cooler and Freezer Case fixtures are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #6. Please specify quantity of end and/or center mount fixtures in Table 2A.23
86ALED Interior High Bay & Low Bay Fixtures or Retrofit Kits ( : 45
• 70% for Vapor Tight fluorescent fixture with one or two T-8, T-5, T-8HO, T-5HO or 3-T8 lamps.
Typically installed in garage, warehouse, food prep, and other industrial applications.
44Clean Room Rated Fluorescent Fixtures - 1x4 or 2x4$30Eligible fixtures must be installed in a clean room rated environment.60
Overall fixture efficiency must be > :
• 75% for Clean Room fluorescent fixture with up to three T-8 or T-5 lamps.
92LED Vapor Tight Fixtures - 4 ft. and 8 ft. Fixtures$20Eligible LED vapor tight fixtures are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #8. 45
83ALED Exterior Fixtures - Garage & Canopy 24/7 Operation$150Eligible LED Fixtures for surface, regressed, canopy mounted vapor tight are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #1, #2, #3 or #4. Must have 8,760 annual hours of operation.60
LED Retrofit kits are not eligible under this measure code. Please see 83B for Retrofit Kit eligibility.
83BLED Exterior Fixtures and Retrofit Kits - Garage & Canopy Dusk to Dawn Operation$100Eligible LED Fixtures or Retrofit Kits for surface, regressed, canopy mounted vapor tight are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #1, #2, #3, or #4, or for retrofit kits #10, #11, #12, or #13. Must have a minimum of 4,380 annual hours of operation.95
85ALED Exterior Wall/Pole/Arm Mounted Area and Flood Fixtures and Retrofit Kits $25Eligible LED exterior wall/pole/arm mounted area or flood fixtures or retrofit kits are required to be listed by the DesignLights Consortium® and must meet DLC Technical Requirements #1, #2, #3, or #4 or for retrofit kits #10, #11, #12, or #13. Must have a minimum of 2,000 annual hours of operation.73
87ALED Exterior Wall/Pole/Arm Mounted Area and Flood Fixtures and Retrofit Kits - Low, Medium, & High Output Dusk to Dawn Operation$75Eligible LED wall/pole/arm mounted area and flood fixtures are required to listed by the DesignLights Consortium® and must meet DLC Technical Requirements #1, #2, #3, or #4 or for Retrofit Kits #10, #11, #12, or #13. Must have a minimum of 4380 annual hours of operation.128
87BLED Exterior Wall/Pole/Arm Mounted Area and Flood Fixtures and Retrofit Kits - Medium & High Output Dusk to Dawn Operation$145Eligible LED wall/pole/arm mounted area and flood fixtures are required to listed by the DesignLights Consortium® and must meet DLC technical Requirements #2, #3, or $4. Retrofit Kits must meet DLC Technical Requirements #11, #12, or #13. Must have a minimum of 4380 annual hours of operation.140
87CLED Exterior Wall/Pole/Arm Mounted Area and Flood Fixtures - High or Very High Output Dusk to Dawn Operation$265Eligible LED wall/pole/arm mounted area and flood Fixtures are required to listed by the DesignLights Consortium® and must meet DLC technical Requirements #3 or #4. LED Retrofit kits are not eligible under this measure code. Please see 87B for Retrofit Kit eligibility. Must have a minimum of 4380 annual hours of operation. 250
Notes:
• Facility lighting must average a minimum of 2,000 hours per year, except Municipal Facilities which must average a minimum of 1,000 hours.
• All proposed Fluorescent Fixtures must be equipped with new T-8 or T-5 lamps and new electronic ballasts that meet current federal energy conservation standards. All 4 ft. fluorescent T-8 lamps must meet or exceed the
Consortium for Energy Efficiency’s (CEE) T-8 replacement lamp specification. For detailed eligibility requirements and a list of qualifying lamps, please log onto CEE’s web site at:www.cee1.org/qualifying T8 lamps
• Energy Star® qualified LED products listings and technical requirements can be found at: www.energystar.gov/LED
• DesignLights Consortium® (DLC) qualified LED products listing and technical requirements can be found at: www.designlights.org
• LED products not found on Energy Star or DLC qualified products lists may be eligible for incentives if found on Lighting Design Labs (LDL) qualified products list which can be found at: https://www.lightingdesignlab.com/led-qpl
National Grid does not warrant or accept any liability whatsoever for LED 2ft. or 4ft. Linear Replacement Lamps or Retrofit Kits that receive incentives through our energy efficiency programs. Customers are responsible for the proper modification and installation of LED 2ft. and 4ft. Linear Replacement Lamps or Retrofit Kits in existing fixtures in accordance with manufacturer’s instructions. Customers should be aware that fixture modifications may void warranty. Customers are responsible for proper labeling of all modified fixtures.
It is the responsibility of the lighting installers to meet current Illuminating Engineering Society standards for light levels, light distribution, uniformity, and lighting quality for all installations.
&5Lighting Systems & Controls 2017 Retrofit Program UNYRev. &D&5&G&5Page &P+3 of 12
https://library.cee1.org/content/commercial-lighting-qualifying-products-listshttps://www.energystar.gov/products/lighting_fans/light_bulbs/learn_about_led_bulbshttp://www.designlights.org/https://www.lightingdesignlab.com/led-qualified-products-lists
Ltg Control Measures-1B
Table 1B: Lighting Controls Eligibility and Incentive Levels ( Complete Table 2B for Lighting Control Installations)
Measure CodeMeasure DescriptionPer Unit IncentiveEligibility CriteriaMin Watts ControlledImage
61Remote Mounted Occupancy Sensor$20Ceiling Mounted Control. Comply with manufacturer coverage recommendations. Manual "ON" overrides are not eligible.60
62Daylight and/or Occupancy Dimming System$15Ballast or LED drivers must be automatically controlled based on daylight or occupancy levels.25
(per fixture)(per fixture)
63Integral Fixture Mounted Dual Sensors & Controllers$25Integral fixture mounted dual sensor with motion and photocell/ambient light sensor. System to control motion response and illumination levels. Only one incentive per fixture.25
(per fixture)(per fixture)
64Wall Mounted Occupancy Sensor$10Occupancy sensor must operate as Automatic On and Off. Sensors must be wall mounted devices only. Vacancy sensors with Manual On, Automatic OFF options are allowed. Manual "ON" overrides are not eligible.40
65Photocell Sensor - Exterior Lighting applications operating 24/7$20Photocell sensor or hard-wired astronomical timer controller for lighting systems that operate 24 hours per day, 7 days per week (8,760 annual hours).50
68Occupancy Sensor for High Bay Fixtures$25Fluorescent ballasts or LED drivers must be automatically controlled based on occupancy. Sensors must be integral (built into) or permanently attached to each fixture. Manual "ON" or overrides are not eligible. 65
(per fixture)(per fixture)
&5Lighting Systems & Controls 2017 Retrofit Program UNYRev. &D&5&G&5Page &P+9 of 12
Worksheet Directions
Directions and Tips in using Spreadsheet
This spreadsheet can be used for a prescriptive OR custom lighting and/or controls project
If using for custom, the measure codes do not have to be selected on the lighting worksheet
Created in Excel 2010. May not be compatible with earlier versions of Excel.
Lighting Worksheet-2A
1.Enter the facility name at top of lighting worksheet (D10), Building Square Footage (H10), and Annual Energy Usage (M10)
~ this will auto fill in the other worksheets, where applicable
2.On the top right of the lighting worksheet (R2:V8) in the first box select from the dropdown menus the appropriate facility type, city, and HVAC system for the site.
3.Complete the necessary # of rows on the lighting worksheet for each area in a building being retrofitted with new lights
~ be as specific as possible with the areas and the lighting descriptions (ex. Office 102, 3 lamp T-8 32W NB 2x4 parabolic troffers)
4.Be sure to identify in column B & C on the lighting worksheet if the area is an interior or exterior space (I or E) and whether or not it is an air conditioned space (Y, N, or R)
5.Specify in column E the annual operating hours of the lights for the area outlined in each row
6.Identify the quantity of existing and proposed lights in columns H & M, for prescriptive applications these quantities should be the same, except when incentives are per lamp
7.Complete the NY Device Codes in columns I & N for existing and proposed lights based on the type of light being used
~ Refer to the NY Device Codes & Rated Wattage table (can be filtered) on this spreadsheet to find the correct device code. This will auto populate columns J & O for the wattage of the fixture
8.In column K select the appropriate measure code (if using for prescriptive application). Refer to worksheet Lighting Measures - 1A
9.If selecting Measure Codes 81 C, D, E, F, or H for linear & pin based LED lamps please complete the following:
~ in the proposed lighting section please enter the total quantity of lamps being installed for that location in column M
~ use the NY Device Code for LED Integral Replacement Lamps that is equal to the system wattage for the lamp; this includes bare lamp and ballast/driver wattage
10.If completing for a prescriptive application the incentives per fixture and total incentives will auto calculate
~ If the proposed system does not meet the measure codes minimum wattage savings requirements (as outlined in Table 1A) a note will appear in column Q stating it does not meet min watts. Check to ensure proper device code is being used or consider another alternative
11.The columns to the right outlining the energy usage and savings will auto calculate based on inputs outlined above
Controls Worksheet-2B
1.If the proposed lighting project includes controls complete all the lighting details first on the Lighting Worksheet
2.Click on the Controls Worksheet and you will see the lighting details entered in the Lighting Worksheet
3.In column C select the appropriate measure code (if using for prescriptive application). Refer to worksheet Ltg Control Measures - 1B
4.For those areas and lights being controlled, in column D select the type of control to be used (ex. Occupancy, daylight, etc.)
5. In column F enter the number of controls being installed for that area
6. In column G the quantity of fixtures being controlled is auto populated from the lighting worksheet. If the quantity of fixtures being controlled differs, change the number to the correct amount
7.The Total Watts controlled will auto calculate based on the % savings as outlined in the NYS Tech Manual
Custom Applications
1.If using the spreadsheet for custom applications please complete the steps above as applicable
2.In column AF select the appropriate Effective Useful Life for the proposed product in the row. 15000 hrs. for decorative LED lamps, 25000 hrs. for all other LED lamps as well as uncertified LEDs, 35000 hrs. for Energy Star LED Fixtures, 50000 hrs. for DLC qualified LEDs, and 70000 for CEE qualified fluorescents
3.On the Project Summary Sheet enter the average electric cost for both supply and delivery as well as the project cost for