new contents iec contactors & starters · 2017. 5. 31. · april 2008 pg03300001e for more...

29
April 2008 PG03300001E For more information visit: www.eaton.com Contents IEC Contactors & Starters 4-1 4 IEC Contactors & Starters Description Page XT IEC Power Control Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3 Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6 Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20 Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23 Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24 Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25 Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27 IEC Starters

Upload: others

Post on 09-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

Contents

IEC Contactors & Starters 4-1

4

IEC

Co

nta

cto

rs &

Sta

rte

rs Description Page

XT IEC Power Control

Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2

Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3

Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6

Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-20

Combination Motor Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23

Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-23

Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24

Cover Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-25

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-27

IEC Starters

Page 2: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-2

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Product DescriptionEaton’s Cutler-Hammer® XT Lineincludes IEC Contactors, Starters and Combination Motor Controllers (CMCs). Designed to meet Inter-national Standards, the Enclosed Control XT Line (ECX), carries UL and cUL certifications.

Features and Benefits■ AC control from 12V to 600V

50/60 Hz■ DC control from 12V to 220V■ Available with screw or spring cage

terminals■ Reversing or non-reversing contac-

tors and starters■ AC-3 contactor ratings to 1000A and

AC-1 contactor ratings to 2000A■ Non-reversing starters to 650A■ Panel or DIN rail mounting to 65A■ IP20 finger and back-of-hand proof■ Large ambient temperature range,

-25 to 50°C [-13 to 122°F]■ AC and DC controlled contactors in

the same compact frame■ Low power consumption DC coils■ Built-in NO or NC auxiliary contacts

to 32A■ Plug-in accessories for reduced

installation time■ Nonmetallic and metallic enclosures

in Types 1 (IP23), 4 (IP66), 4X (IP66), 12 (IP65) and 3R (IP32)

■ Circuit breakers, fused, non-fused and non-combination designs available

■ Opaque (standard) or clear covers available on nonmetallic Halyester enclosure option

Short Circuit Ratings■ Fused, Non-fused

❑ 10K AIC @ 600V■ HMCP

❑ 0 – 10 hp 15K AIC @ 600V❑ 15 – 125 hp 25K AIC @ 600V

■ Non-combination❑ 0 – 1 hp 1K AIC @ 600V❑ 1.5 – 50 hp 5K AIC @ 600V❑ 50 – 200 hp 10K AIC @ 600V

Standards and CertificationsNote: See Page 18-2 for additional informa-tion on Standards and Certifications that apply to all Cutler-Hammer Enclosed Control products.

■ Fusible — with Class J fuses❑ UL Listed❑ cUL Listed �

■ Circuit Breaker HMCP/E❑ UL Listed❑ cUL Listed �

� cUL Listing indicates appropriate CSA standard investigation.

ECX Enclosed Control

Page 3: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-3IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Catalog Number SelectionTable 4-1. IEC XT Line Enclosed Control Catalog Numbering System

� See Table 1-2 on Page 1-4 for Enclosure Type/IP Rating Cross-Reference.

Table 4-2. XTOB Overload Relays for Enclosed XT

� Size B – E is 10 – 16A.

FLARatings

Size B – E7 – 15A

Size F – H18 – 32A

Size J – L40 – 65A

Size M – N80 – 95A

Size P – Q115 – 150A

FLARatings

Size B – E7 – 15A

Size F – H18 – 32A

Size J – L40 – 65A

Size M – N80 – 95A

Size P – Q115 – 150A

0.1 – 0.160.16 – 0.240.24 – 0.40.4 – 0.6

ABCD

ABCD

————

————

————

16 – 2424 – 3224 – 4025 – 35

————

MN——

M—P—

———S

———S

0.6 – 11 – 1.61.6 – 2.42.4 – 4

EFGH

EFGH

————

————

————

35 – 5040 – 5750 – 6550 – 70

————

————

—QR—

T——U

T——U

4 – 66 – 109 – 12

12 – 16

IJKL �

IJ—L

—J—L

————

————

70 – 10095 – 125

——

——

——

V—

VW

E C X 2 5 E 5 A A A -

Modification Codes

See Page 16-40

Disconnect Fuse Clip Ratings

A =C =E =G =

None30A J60A J

100A J

HMCP Ratings

A =B =C =D =E =F =

W =G =H =J =

None3A7A

15A30A50A70A

100A150A250A

Design

X = XT IEC

Frame Size

Combination(Class 16 – 74)

Non-combination (Class 09 – 11)Ampere Rating (UL 600V)

IEC Size B – Q B =C =D =E =F =G =H =

7A9A

12A15A18A25A32A

J =K =L =M =N =P =Q =

40A50A65A80A95A

115A150A

Coil Voltage

A =B =C =D =E =

120V240V480V600V208V

H =L =Q =T =

277V380V/50 Hz24V DC24V AC

Overload Range

See Table 4-2

Enclosure Type/IP Ratings �

1 =3 =4 =5 =8 =

Type 1— General Purpose/IP23Type 4 — Painted Steel/IP66Type 4X — Watertight (304-Grade Stainless Steel)/IP66Type 4X — Watertight (Non-metallic)/IP66Type 12 — Dust-Tight/IP65

Cover Control

Type 1 Non-comb. Starters see Table 4-3All Other Starters see Table 4-4E22 Style Comb. Starters see Table 4-5

Class Table

09 = Non-combination Non-reversing Starter 4-6

10 = Non-combination Reversing Starter 4-7

11 = Non-combination Non-reversing Starter with CPT

4-8

19 = Combination Non-reversing Starter — Fusible/Non-fusible Disconnect

4-9

20 = Combination Reversing Starter — Fusible/Non-fusible Disconnect

4-10

25 = Combination Non-reversing Starter — Circuit Breaker

4-11

26 = Combination Reversing Starter —Circuit Breaker

4-12

Page 4: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-4

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Cover ControlNon-combination StartersControl Power Transformer (CPT) may be required.

Combination Starters■ Cover control for Combination Starters uses 10250T style

devices as standard.■ E22 style cover control options are available (Table 4-5).■ Selector switches are maintained with lever operators.■ Pushbuttons are momentary type with extended

pushbutton.■ The kit includes hardware and connecting wires (where

possible).■ For factory installed control devices other than shown

below, refer to Modification Codes, Page 16-40.

Table 4-3. Type 1 Non-combination Cover Control

� For more available factory installed flange control, see Table 4-4.� Add Code Letter from the table below to Catalog Number for voltage —

Kits only. Example: C400T9B.

Table 4-4. Type 1 Combination and All Type 3R, 4X and 12 Cover Control �

� For Type 1 Non-combination field installation kits, see Table 4-3.� Add Code Letter from the table below to Catalog Number for voltage —

Kits only. Example: C400T9B.

� Order Quantity (2) of C400T10.

Description Factory InstalledFlange Control �

FieldInstallation Kits

Position9 Code

CatalogNumber

Non-reversingNo Cover Mounted Pilot DevicesSTART/STOP Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

ABCD

C400GK0C400GK1C400GK12 �

C400GK16 �

HAND/OFF/AUTO Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

HJK

C400GK3C400GK32 �

C400GK36 �

Red RUN Pilot LightGreen OFFRed RUN/Green OFF Pilot Lights

PQR

C400GK42 �

C400GK41 �

C400GK46 �

ReversingNo Cover Mounted Pilot DevicesFOR/REV/STOP Pushbuttonswith 2 Red Pilot Lights

ABC

C400GK0C400GR1C400GR14 �

UP/STOP/DOWN Pushbuttonswith 2 Red Pilot Lights

EF

C400GR2C400GR24 �

Two Red Pilot LightsOne Green Pilot Light

PQ

C400GK44 �

C400GK41 �

Rating Code Letter

Rating Code Letter

Rating Code Letter

120V 60 Hz208V 60 Hz240V 60 Hz

AEB

277V 60 Hz380V 50 Hz

HL

480V 60 Hz600V 60 Hz

CD

Type 1 Cover Control

Description Factory InstalledFlange Control

FieldInstallation Kits

Position9 Code

CatalogNumber

Non-reversingNo Cover Mounted Pilot DevicesSTART/STOP Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

ABCD

—C400T1——

ON/OFF Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

EFG

C400T2——

HAND/OFF/AUTO Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

HJK

C400T12——

START PushbuttonON PushbuttonOFF PushbuttonRed RUN Pilot LightGreen OFFRed RUN/Green OFF Pilot Lights

LMNPQR

C400T3C400T4C400T5C400T9 �

C400T10 �

C400T11 �

START/STOP Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

STU

C400T13——

ON/OFF Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

VWX

C400T14——

ReversingNo Cover Mounted Pilot DevicesFOR/REV/STOP Pushbuttonswith 2 Red Pilot Lightswith 2 Red/1 Green Pilot Lights

ABCD

—C400T6——

UP/STOP/DOWN Pushbuttonswith 2 Red Pilot Lights

EF

——

FOR/OFF/REV Selector Switchwith 2 Red Pilot Lightswith 2 Red/1 Green Pilot Lights

HJK

C400T15——

Two Red Pilot LightsOne Green Pilot LightTwo Red/One Green Pilot LightsOPEN/OFF/CLOSE Selector Switchwith 2 Red Pilot Lightswith 2 Red/1 Green Pilot Lights

PQRVWX

C400T10 �

—C400T16——

Rating Code Letter

Rating Code Letter

Rating Code Letter

120V 60 Hz208V 60 Hz240V 60 Hz

AEB

277V 60 Hz380V 50 Hz

HL

480V 60 Hz600V 60 Hz

CD

10250T Selector Switch

Page 5: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

PG03300001E For more information visit: www.eaton.com

4-5IEC Contactors & Starters

April 2008

4

XT IEC Power ControlContactors and Starters

Table 4-5. Type 1, 3R, 4X and 12 E22 Style Combination Starter Cover Control

� To include any of the above cover controls, place the control code character in position 9 of your Catalog Number and add Mod Code C29.Example: EXE19B4ADA_-C29.Full voltage non-reversing fusible starter with START/STOP pushbutton with red RUN and green OFF pilot lights.

� Suffix for lights (required for field installed kits only) in the table below:

Description Factory Installed � Field Installation Kits

Position 9Cover ControlCode

CombinationOnly

CatalogNumber

Non-reversingNo Cover Mounted Pilot DevicesSTART/STOP Pushbuttons (PB)START/STOP PB & Red RUN LightSTART/STOP PB, Red RUN, & Green STOPPED LightHAND/OFF/AUTO Selector Switch (SS)H-O-A SS & Red RUN Light

ABCDHJ

—CE400T01CE400T02 �

CE400T03 �

CE400T04CE400T05 �

H-O-A SS, Red RUN, & Green STOPPED LightRed RUN Pilot LightGreen Off Pilot LightRed RUN/Green OFF Pilot LightON/OFF Selector Switch (SS)

KPQRS

CE400T06 �

CE400T10 �

CE400T11 �

CE400T12 �

CE400T07

ON/OFF SS, Red RUN LightON/OFF SS, Red RUN, & Green STOPPED Light

TU

CE400T08 �

CE400T09 �

ReversingNo Cover Mounted Pilot DevicesFWD/REV/STOP Pushbuttons (PB)FWD/REV/STOP PB + Red FWD & REV LightsFWD/REV/STOP PB, Red FWD/REV, & Green STOPPEDFOR/OFF/REV Selector Switch (SS)FOR/OFF/REV SS + Red FWD & REV Lights

ABCDHJ

—CE400T50CE400T51 �

CE400T52 �

CE400T53CE400T54 �

FOR/OFF/REV SS, Red FWD/REV, & Green STOPPEDOPEN/OFF/CLOSE Selector Switch (SS)OPEN/OFF/CLOSE SS + Red FWD & REV LightsOPEN/OFF/CLOSE SS, Red FWD/REV, & Green STOPPED

KVWX

CE400T55 �

CE400T56CE400T57 �

CE400T58 �

Rating Code Letter Rating Code Letter Rating Code Letter

120V 60 Hz208V 60 Hz240V 60 Hz

AEB

277V 60 Hz380V 50 Hz

HL

480V 60 Hz600V 60 Hz

CD

E22 Selector Switch

Page 6: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-6

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Product SelectionTable 4-6. Class ECX09 — Non-combination Non-reversing Starter

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX09B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame B7 115

208230380460575

1/4 3/4

1———

—1-1/22335

120208240380/50 Hz480600

ECX09B1AAA-_ECX09B1EAA-_ECX09B1BAA-_ECX09B1LAA-_ECX09B1CAA-_ECX09B1DAA-_

ECX09B4AAA-_ECX09B4EAA-_ECX09B4BAA-_ECX09B4LAA-_ECX09B4CAA-_ECX09B4DAA-_

ECX09B8AAA-_ECX09B8EAA-_ECX09B8BAA-_ECX09B8LAA-_ECX09B8CAA-_ECX09B8DAA-_

XTAE007B10A_XTAE007B10E_XTAE007B10B_XTAE007B10L_XTAE007B10C_XTAE007B10D_

Frame C9 115

208230380460575

1/211-1/2

———

—23557-1/2

120208240380/50 Hz480600

ECX09C1AAA-_ECX09C1EAA-_ECX09C1BAA-_ECX09C1LAA-_ECX09C1CAA-_ECX09C1DAA-_

ECX09C4AAA-_ECX09C4EAA-_ECX09C4BAA-_ECX09C4LAA-_ECX09C4CAA-_ECX09C4DAA-_

ECX09C8AAA-_ECX09C8EAA-_ECX09C8BAA-_ECX09C8LAA-_ECX09C8CAA-_ECX09C8DAA-_

XTAE009B10A_XTAE009B10E_XTAE009B10B_XTAE009B10L_XTAE009B10C_XTAE009B10D_

Frame D12 115

208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX09D1AAA-_ECX09D1EAA-_ECX09D1BAA-_ECX09D1LAA-_ECX09D1CAA-_ECX09D1DAA-_

ECX09D4AAA-_ECX09D4EAA-_ECX09D4BAA-_ECX09D4LAA-_ECX09D4CAA-_ECX09D4DAA-_

ECX09D8AAA-_ECX09D8EAA-_ECX09D8BAA-_ECX09D8LAA-_ECX09D8CAA-_ECX09D8DAA-_

XTAE012B10A_XTAE012B10E_XTAE012B10B_XTAE012B10L_XTAE012B10C_XTAE012B10D_

Frame E15 115

208230380460575

3/422

———

—3357-1/2

10

120208240380/50 Hz480600

ECX09E1AAA-_ECX09E1EAA-_ECX09E1BAA-_ECX09E1LAA-_ECX09E1CAA-_ECX09E1DAA-_

ECX09E4AAA-_ECX09E4EAA-_ECX09E4BAA-_ECX09E4LAA-_ECX09E4CAA-_ECX09E4DAA-_

ECX09E8AAA-_ECX09E8EAA-_ECX09E8BAA-_ECX09E8LAA-_ECX09E8CAA-_ECX09E8DAA-_

XTAE015B10A_XTAE015B10E_XTAE015B10B_XTAE015B10L_XTAE015B10C_XTAE015B10D_

Frame F18 115

208230380460575

223

———

—557-1/2

1015

120208240380/50 Hz480600

ECX09F1AAA-_ECX09F1EAA-_ECX09F1BAA-_ECX09F1LAA-_ECX09F1CAA-_ECX09F1DAA-_

ECX09F4AAA-_ECX09F4EAA-_ECX09F4BAA-_ECX09F4LAA-_ECX09F4CAA-_ECX09F4DAA-_

ECX09F8AAA-_ECX09F8EAA-_ECX09F8BAA-_ECX09F8LAA-_ECX09F8CAA-_ECX09F8DAA-_

XTAE018C10A_XTAE018C10E_XTAE018C10B_XTAE018C10L_XTAE018C10C_XTAE018C10D_

Frame G25 115

208230380460575

235

———

—7-1/27-1/2

101510

120208240380/50 Hz480600

ECX09G1AAA-_ECX09G1EAA-_ECX09G1BAA-_ECX09G1LAA-_ECX09G1CAA-_ECX09G1DAA-_

ECX09G4AAA-_ECX09G4EAA-_ECX09G4BAA-_ECX09G4LAA-_ECX09G4CAA-_ECX09G4DAA-_

ECX09G8AAA-_ECX09G8EAA-_ECX09G8BAA-_ECX09G8LAA-_ECX09G8CAA-_ECX09G8DAA-_

XTAE025C10A_XTAE025C10E_XTAE025C10B_XTAE025C10L_XTAE025C10C_XTAE025C10D_

Frame H32 115

208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX09H1AAA-_ECX09H1EAA-_ECX09H1BAA-_ECX09H1LAA-_ECX09H1CAA-_ECX09H1DAA-_

ECX09H4AAA-_ECX09H4EAA-_ECX09H4BAA-_ECX09H4LAA-_ECX09H4CAA-_ECX09H4DAA-_

ECX09H8AAA-_ECX09H8EAA-_ECX09H8BAA-_ECX09H8LAA-_ECX09H8CAA-_ECX09H8DAA-_

XTAE032C10A_XTAE032C10E_XTAE032C10B_XTAE032C10L_XTAE032C10C_XTAE032C10D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . Page 18-19

Page 7: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-7IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-6. Class ECX09 — Non-combination Non-reversing Starter (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX09B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame J40 115

208230380460575

357-1/2

———

—1015153040

120208240380/50 Hz480600

ECX09J1AAA-_ECX09J1EAA-_ECX09J1BAA-_ECX09J1LAA-_ECX09J1CAA-_ECX09J1DAA-_

ECX09J4AAA-_ECX09J4EAA-_ECX09J4BAA-_ECX09J4LAA-_ECX09J4CAA-_ECX09J4DAA-_

ECX09J8AAA-_ECX09J8EAA-_ECX09J8BAA-_ECX09J8LAA-_ECX09J8CAA-_ECX09J8DAA-_

XTAE040D00A_XTAE040D00E_XTAE040D00D_XTAE040D00L_XTAE040D00C_XTAE040D00D_

Frame K50 115

208230380460575

37-1/2

10———

—1520204050

120208240380/50 Hz480600

ECX09K1AAA-_ECX09K1EAA-_ECX09K1BAA-_ECX09K1LAA-_ECX09K1CAA-_ECX09K1DAA-_

ECX09K4AAA-_ECX09K4EAA-_ECX09K4BAA-_ECX09K4LAA-_ECX09K4CAA-_ECX09K4DAA-_

ECX09K8AAA-_ECX09K8EAA-_ECX09K8BAA-_ECX09K8LAA-_ECX09K8CAA-_ECX09K8DAA-_

XTAE050D00A_XTAE050D00E_XTAE050D00B_XTAE050D00L_XTAE050D00C_XTAE050D00D_

Frame L65 115

208230380460575

51015———

—2025305060

120208240380/50 Hz480600

ECX09L1AAA-_ECX09L1EAA-_ECX09L1BAA-_ECX09L1LAA-_ECX09L1CAA-_ECX09L1DAA-_

ECX09L4AAA-_ECX09L4EAA-_ECX09L4BAA-_ECX09L4LAA-_ECX09L4CAA-_ECX09L4DAA-_

ECX09L8AAA-_ECX09L8EAA-_ECX09L8BAA-_ECX09L8LAA-_ECX09L8CAA-_ECX09L8DAA-_

XTAE065D00A_XTAE065D00E_XTAE065D00B_XTAE065D00L_XTAE065D00C_XTAE065D00D_

Frame M80 115

208230380460575

7-1/21515———

—2530506075

120208240380/50 Hz480600

ECX09M1AAA-_ECX09M1EAA-_ECX09M1BAA-_ECX09M1LAA-_ECX09M1CAA-_ECX09M1DAA-_

ECX09M4AAA-_ECX09M4EAA-_ECX09M4BAA-_ECX09M4LAA-_ECX09M4CAA-_ECX09M4DAA-_

ECX09M8AAA-_ECX09M8EAA-_ECX09M8BAA-_ECX09M8LAA-_ECX09M8CAA-_ECX09M8DAA-_

XTAE080F00A_XTAE080F00E_XTAE080F00B_XTAE080F00L_XTAE080F00C_XTAE080F00D_

Frame N95 115

208230380460575

7-1/21515———

—25406075

100

120208240380/50 Hz480600

ECX09N1AAA-_ECX09N1EAA-_ECX09N1BAA-_ECX09N1LAA-_ECX09N1CAA-_ECX09N1DAA-_

ECX09N4AAA-_ECX09N4EAA-_ECX09N4BAA-_ECX09N4LAA-_ECX09N4CAA-_ECX09N4DAA-_

ECX09N8AAA-_ECX09N8EAA-_ECX09N8BAA-_ECX09N8LAA-_ECX09N8CAA-_ECX09N8DAA-_

XTAE095F00A_XTAE095F00E_XTAE095F00B_XTAE095F00L_XTAE095F00C_XTAE095F00D_

Frame P115 115

208230380460575

102525———

—405060

100125

120208240380/50 Hz480600

ECX09P1AAA-_ECX09P1EAA-_ECX09P1BAA-_ECX09P1LAA-_ECX09P1CAA-_ECX09P1DAA-_

ECX09P4AAA-_ECX09P4EAA-_ECX09P4BAA-_ECX09P4LAA-_ECX09P4CAA-_ECX09P4DAA-_

ECX09P8AAA-_ECX09P8EAA-_ECX09P8BAA-_ECX09P8LAA-_ECX09P8CAA-_ECX09P8DAA-_

XTAE115G00A_XTAE115G00E_XTAE115G00B_XTAE115G00L_XTAE115G00C_XTAE115G00D_

Frame Q150 115

208230380460575

152530———

—406060

125150

120208240380/50 Hz480600

ECX09Q1AAA-_ECX09Q1EAA-_ECX09Q1BAA-_ECX09Q1LAA-_ECX09Q1CAA-_ECX09Q1DAA-_

ECX09Q4AAA-_ECX09Q4EAA-_ECX09Q4BAA-_ECX09Q4LAA-_ECX09Q4CAA-_ECX09Q4DAA-_

ECX09Q8AAA-_ECX09Q8EAA-_ECX09Q8BAA-_ECX09Q8LAA-_ECX09Q8CAA-_ECX09Q8DAA-_

XTAE150G00A_XTAE150G00E_XTAE150G00B_XTAE150G00L_XTAE150G00C_XTAE150G00D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . . Page 18-19

Page 8: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-8

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-7. Class ECX10 — Non-combination Reversing Starter

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX10B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame B7 115

208230380460575

1/4 3/4

1———

—1-1/22335

120208240380/50 Hz480600

ECX10B1AAA-_ECX10B1EAA-_ECX10B1BAA-_ECX10B1LAA-_ECX10B1CAA-_ECX10B1DAA-_

ECX10B4AAA-_ECX10B4EAA-_ECX10B4BAA-_ECX10B4LAA-_ECX10B4CAA-_ECX10B4DAA-_

ECX10B8AAA-_ECX10B8EAA-_ECX10B8BAA-_ECX10B8LAA-_ECX10B8CAA-_ECX10B8DAA-_

XTAR007B10A_XTAR007B10E_XTAR007B10B_XTAR007B10L_XTAR007B10C_XTAR007B10D_

Frame C9 115

208230380460575

1/211-1/2

———

—23557-1/2

120208240380/50 Hz480600

ECX10C1AAA-_ECX10C1EAA-_ECX10C1BAA-_ECX10C1LAA-_ECX10C1CAA-_ECX10C1DAA-_

ECX10C4AAA-_ECX10C4EAA-_ECX10C4BAA-_ECX10C4LAA-_ECX10C4CAA-_ECX10C4DAA-_

ECX10C8AAA-_ECX10C8EAA-_ECX10C8BAA-_ECX10C8LAA-_ECX10C8CAA-_ECX10C8DAA-_

XTAR009B10A_XTAR009B10E_XTAR009B10B_XTAR009B10L_XTAR009B10C_XTAR009B10D_

Frame D12 115

208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX10D1AAA-_ECX10D1EAA-_ECX10D1BAA-_ECX10D1LAA-_ECX10D1CAA-_ECX10D1DAA-_

ECX10D4AAA-_ECX10D4EAA-_ECX10D4BAA-_ECX10D4LAA-_ECX10D4CAA-_ECX10D4DAA-_

ECX10D8AAA-_ECX10D8EAA-_ECX10D8BAA-_ECX10D8LAA-_ECX10D8CAA-_ECX10D8DAA-_

XTAR012B10A_XTAR012B10E_XTAR012B10B_XTAR012B10L_XTAR012B10C_XTAR012B10D_

Frame E15 115

208230380460575

3/422

———

—3357-1/2

10

120208240380/50 Hz480600

ECX10E1AAA-_ECX10E1EAA-_ECX10E1BAA-_ECX10E1LAA-_ECX10E1CAA-_ECX10E1DAA-_

ECX10E4AAA-_ECX10E4EAA-_ECX10E4BAA-_ECX10E4LAA-_ECX10E4CAA-_ECX10E4DAA-_

ECX10E8AAA-_ECX10E8EAA-_ECX10E8BAA-_ECX10E8LAA-_ECX10E8CAA-_ECX10E8DAA-_

XTAR015B10A_XTAR015B10E_XTAR015B10B_XTAR015B10L_XTAR015B10C_XTAR015B10D_

Frame F18 115

208230380460575

223

———

—557-1/2

1015

120208240380/50 Hz480600

ECX10F1AAA-_ECX10F1EAA-_ECX10F1BAA-_ECX10F1LAA-_ECX10F1CAA-_ECX10F1DAA-_

ECX10F4AAA-_ECX10F4EAA-_ECX10F4BAA-_ECX10F4LAA-_ECX10F4CAA-_ECX10F4DAA-_

ECX10F8AAA-_ECX10F8EAA-_ECX10F8BAA-_ECX10F8LAA-_ECX10F8CAA-_ECX10F8DAA-_

XTAR018C10A_XTAR018C10E_XTAR018C10B_XTAR018C10L_XTAR018C10C_XTAR018C10D_

Frame G25 115

208230380460575

235

———

—7-1/27-1/2

101510

120208240380/50 Hz480600

ECX10G1AAA-_ECX10G1EAA-_ECX10G1BAA-_ECX10G1LAA-_ECX10G1CAA-_ECX10G1DAA-_

ECX10G4AAA-_ECX10G4EAA-_ECX10G4BAA-_ECX10G4LAA-_ECX10G4CAA-_ECX10G4DAA-_

ECX10G8AAA-_ECX10G8EAA-_ECX10G8BAA-_ECX10G8LAA-_ECX10G8CAA-_ECX10G8DAA-_

XTAR025C10A_XTAR025C10E_XTAR025C10B_XTAR025C10L_XTAR025C10C_XTAR025C10D_

Frame H32 115

208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX10H1AAA-_ECX10H1EAA-_ECX10H1BAA-_ECX10H1LAA-_ECX10H1CAA-_ECX10H1DAA-_

ECX10H4AAA-_ECX10H4EAA-_ECX10H4BAA-_ECX10H4LAA-_ECX10H4CAA-_ECX10H4DAA-_

ECX10H8AAA-_ECX10H8EAA-_ECX10H8BAA-_ECX10H8LAA-_ECX10H8CAA-_ECX10H8DAA-_

XTAR032C10A_XTAR032C10E_XTAR032C10B_XTAR032C10L_XTAR032C10C_XTAR032C10D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . Page 18-19

Page 9: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-9IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-7. Class ECX10 — Non-combination Reversing Starter (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX10B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame J40 115

208230380460575

357-1/2

———

—1015153040

120208240380/50 Hz480600

ECX10J1AAA-_ECX10J1EAA-_ECX10J1BAA-_ECX10J1LAA-_ECX10J1CAA-_ECX10J1DAA-_

ECX10J4AAA-_ECX10J4EAA-_ECX10J4BAA-_ECX10J4LAA-_ECX10J4CAA-_ECX10J4DAA-_

ECX10J8AAA-_ECX10J8EAA-_ECX10J8BAA-_ECX10J8LAA-_ECX10J8CAA-_ECX10J8DAA-_

XTAR040D00A_XTAR040D00E_XTAR040D00B_XTAR040D00L_XTAR040D00C_XTAR040D00D_

Frame K50 115

208230380460575

37-1/2

10———

—1520204050

120208240380/50 Hz480600

ECX10K1AAA-_ECX10K1EAA-_ECX10K1BAA-_ECX10K1LAA-_ECX10K1CAA-_ECX10K1DAA-_

ECX10K4AAA-_ECX10K4EAA-_ECX10K4BAA-_ECX10K4LAA-_ECX10K4CAA-_ECX10K4DAA-_

ECX10K8AAA-_ECX10K8EAA-_ECX10K8BAA-_ECX10K8LAA-_ECX10K8CAA-_ECX10K8DAA-_

XTAR050D00A_XTAR050D00E_XTAR050D00B_XTAR050D00L_XTAR050D00C_XTAR050D00D_

Frame L65 115

208230380460575

51015———

—2025305060

120208240380/50 Hz480600

ECX10L1AAA-_ECX10L1EAA-_ECX10L1BAA-_ECX10L1LAA-_ECX10L1CAA-_ECX10L1DAA-_

ECX10L4AAA-_ECX10L4EAA-_ECX10L4BAA-_ECX10L4LAA-_ECX10L4CAA-_ECX10L4DAA-_

ECX10L8AAA-_ECX10L8EAA-_ECX10L8BAA-_ECX10L8LAA-_ECX10L8CAA-_ECX10L8DAA-_

XTAR065D00A_XTAR065D00E_XTAR065D00B_XTAR065D00L_XTAR065D00C_XTAR065D00D_

Frame M80 115

208230380460575

7-1/21515———

—2530506075

120208240380/50 Hz480600

ECX10M1AAA-_ECX10M1EAA-_ECX10M1BAA-_ECX10M1LAA-_ECX10M1CAA-_ECX10M1DAA-_

ECX10M4AAA-_ECX10M4EAA-_ECX10M4BAA-_ECX10M4LAA-_ECX10M4CAA-_ECX10M4DAA-_

ECX10M8AAA-_ECX10M8EAA-_ECX10M8BAA-_ECX10M8LAA-_ECX10M8CAA-_ECX10M8DAA-_

XTAR080F00A_XTAR080F00E_XTAR080F00B_XTAR080F00L_XTAR080F00C_XTAR080F00D_

Frame N95 115

208230380460575

7-1/21515———

—25406075

100

120208240380/50 Hz480600

ECX10N1AAA-_ECX10N1EAA-_ECX10N1BAA-_ECX10N1LAA-_ECX10N1CAA-_ECX10N1DAA-_

ECX10N4AAA-_ECX10N4EAA-_ECX10N4BAA-_ECX10N4LAA-_ECX10N4CAA-_ECX10N4DAA-_

ECX10N8AAA-_ECX10N8EAA-_ECX10N8BAA-_ECX10N8LAA-_ECX10N8CAA-_ECX10N8DAA-_

XTAR095F00A_XTAR095F00E_XTAR095F00B_XTAR095F00L_XTAR095F00C_XTAR095F00D_

Frame P115 115

208230380460575

102525———

—405060

100125

120208240380/50 Hz480600

ECX10P1AAA-_ECX10P1EAA-_ECX10P1BAA-_ECX10P1LAA-_ECX10P1CAA-_ECX10P1DAA-_

ECX10P4AAA-_ECX10P4EAA-_ECX10P4BAA-_ECX10P4LAA-_ECX10P4CAA-_ECX10P4DAA-_

ECX10P8AAA-_ECX10P8EAA-_ECX10P8BAA-_ECX10P8LAA-_ECX10P8CAA-_ECX10P8DAA-_

XTAR115G00A_XTAR115G00E_XTAR115G00B_XTAR115G00L_XTAR115G00C_XTAR115G00D_

Frame Q150 115

208230380460575

152530———

—406060

125150

120208240380/50 Hz480600

ECX10Q1AAA-_ECX10Q1EAA-_ECX10Q1BAA-_ECX10Q1LAA-_ECX10Q1CAA-_ECX10Q1DAA-_

ECX10Q4AAA-_ECX10Q4EAA-_ECX10Q4BAA-_ECX10Q4LAA-_ECX10Q4CAA-_ECX10Q4DAA-_

ECX10Q8AAA-_ECX10Q8EAA-_ECX10Q8BAA-_ECX10Q8LAA-_ECX10Q8CAA-_ECX10Q8DAA-_

XTAR150G00A_XTAR150G00E_XTAR150G00B_XTAR150G00L_XTAR150G00C_XTAR150G00D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . . Page 18-19

Page 10: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-10

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-8. Class ECX11 — Non-combination Non-reversing Starter with CPT

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX11B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame B7 115

208230380460575

1/4 3/4

1———

—1-1/22335

120208240380/50 Hz480600

ECX11B1AAA-_ECX11B1EAA-_ECX11B1BAA-_ECX11B1LAA-_ECX11B1CAA-_ECX11B1DAA-_

ECX11B4AAA-_ECX11B4EAA-_ECX11B4BAA-_ECX11B4LAA-_ECX11B4CAA-_ECX11B4DAA-_

ECX11B8AAA-_ECX11B8EAA-_ECX11B8BAA-_ECX11B8LAA-_ECX11B8CAA-_ECX11B8DAA-_

XTAE007B10A_XTAE007B10E_XTAE007B10B_XTAE007B10L_XTAE007B10C_XTAE007B10D_

Frame C9 115

208230380460575

1/211-1/2

———

—23557-1/2

120208240380/50 Hz480600

ECX11C1AAA-_ECX11C1EAA-_ECX11C1BAA-_ECX11C1LAA-_ECX11C1CAA-_ECX11C1DAA-_

ECX11C4AAA-_ECX11C4EAA-_ECX11C4BAA-_ECX11C4LAA-_ECX11C4CAA-_ECX11C4DAA-_

ECX11C8AAA-_ECX11C8EAA-_ECX11C8BAA-_ECX11C8LAA-_ECX11C8CAA-_ECX11C8DAA-_

XTAE009B10A_XTAE009B10E_XTAE009B10B_XTAE009B10L_XTAE009B10C_XTAE009B10D_

Frame D12 115

208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX11D1AAA-_ECX11D1EAA-_ECX11D1BAA-_ECX11D1LAA-_ECX11D1CAA-_ECX11D1DAA-_

ECX11D4AAA-_ECX11D4EAA-_ECX11D4BAA-_ECX11D4LAA-_ECX11D4CAA-_ECX11D4DAA-_

ECX11D8AAA-_ECX11D8EAA-_ECX11D8BAA-_ECX11D8LAA-_ECX11D8CAA-_ECX11D8DAA-_

XTAE012B10A_XTAE012B10E_XTAE012B10B_XTAE012B10L_XTAE012B10C_XTAE012B10D_

Frame E15 115

208230380460575

3/422

———

—3357-1/2

10

120208240380/50 Hz480600

ECX11E1AAA-_ECX11E1EAA-_ECX11E1BAA-_ECX11E1LAA-_ECX11E1CAA-_ECX11E1DAA-_

ECX11E4AAA-_ECX11E4EAA-_ECX11E4BAA-_ECX11E4LAA-_ECX11E4CAA-_ECX11E4DAA-_

ECX11E8AAA-_ECX11E8EAA-_ECX11E8BAA-_ECX11E8LAA-_ECX11E8CAA-_ECX11E8DAA-_

XTAE015B10A_XTAE015B10E_XTAE015B10B_XTAE015B10L_XTAE015B10C_XTAE015B10D_

Frame F18 115

208230380460575

223

———

—557-1/2

1015

120208240380/50 Hz480600

ECX11F1AAA-_ECX11F1EAA-_ECX11F1BAA-_ECX11F1LAA-_ECX11F1CAA-_ECX11F1DAA-_

ECX11F4AAA-_ECX11F4EAA-_ECX11F4BAA-_ECX11F4LAA-_ECX11F4CAA-_ECX11F4DAA-_

ECX11F8AAA-_ECX11F8EAA-_ECX11F8BAA-_ECX11F8LAA-_ECX11F8CAA-_ECX11F8DAA-_

XTAE018C10A_XTAE018C10E_XTAE018C10B_XTAE018C10L_XTAE018C10C_XTAE018C10D_

Frame G25 115

208230380460575

235

———

—7-1/27-1/2

101520

120208240380/50 Hz480600

ECX11G1AAA-_ECX11G1EAA-_ECX11G1BAA-_ECX11G1LAA-_ECX11G1CAA-_ECX11G1DAA-_

ECX11G4AAA-_ECX11G4EAA-_ECX11G4BAA-_ECX11G4LAA-_ECX11G4CAA-_ECX11G4DAA-_

ECX11G8AAA-_ECX11G8EAA-_ECX11G8BAA-_ECX11G8LAA-_ECX11G8CAA-_ECX11G8DAA-_

XTAE025C10A_XTAE025C10E_XTAE025C10B_XTAE025C10L_XTAE025C10C_XTAE025C10D_

Frame H32 115

208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX11H1AAA-_ECX11H1EAA-_ECX11H1BAA-_ECX11H1LAA-_ECX11H1CAA-_ECX11H1DAA-_

ECX11H4AAA-_ECX11H4EAA-_ECX11H4BAA-_ECX11H4LAA-_ECX11H4CAA-_ECX11H4DAA-_

ECX11H8AAA-_ECX11H8EAA-_ECX11H8BAA-_ECX11H8LAA-_ECX11H8CAA-_ECX11H8DAA-_

XTAE032C10A_XTAE032C10E_XTAE032C10B_XTAE032C10L_XTAE032C10C_XTAE032C10D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . Page 18-19

Page 11: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-11IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-8. Class ECX11 — Non-combination Non-reversing Starter with CPT (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX11B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame J40 115

208230380460575

357-1/2

———

—1015153040

120208240380/50 Hz480600

ECX11J1AAA-_ECX11J1EAA-_ECX11J1BAA-_ECX11J1LAA-_ECX11J1CAA-_ECX11J1DAA-_

ECX11J4AAA-_ECX11J4EAA-_ECX11J4BAA-_ECX11J4LAA-_ECX11J4CAA-_ECX11J4DAA-_

ECX11J8AAA-_ECX11J8EAA-_ECX11J8BAA-_ECX11J8LAA-_ECX11J8CAA-_ECX11J8DAA-_

XTAE040D00A_XTAE040D00E_XTAE040D00B_XTAE040D00L_XTAE040D00C_XTAE040D00D_

Frame K50 115

208230380460575

37-1/2

10———

—1520204050

120208240380/50 Hz480600

ECX11K1AAA-_ECX11K1EAA-_ECX11K1BAA-_ECX11K1LAA-_ECX11K1CAA-_ECX11K1DAA-_

ECX11K4AAA-_ECX11K4EAA-_ECX11K4BAA-_ECX11K4LAA-_ECX11K4CAA-_ECX11K4DAA-_

ECX11K8AAA-_ECX11K8EAA-_ECX11K8BAA-_ECX11K8LAA-_ECX11K8CAA-_ECX11K8DAA-_

XTAE050D00A_XTAE050D00E_XTAE050D00B_XTAE050D00L_XTAE050D00C_XTAE050D00D_

Frame L65 115

208230380460575

51015———

—2025305060

120208240380/50 Hz480600

ECX11L1AAA-_ECX11L1EAA-_ECX11L1BAA-_ECX11L1LAA-_ECX11L1CAA-_ECX11L1DAA-_

ECX11L4AAA-_ECX11L4EAA-_ECX11L4BAA-_ECX11L4LAA-_ECX11L4CAA-_ECX11L4DAA-_

ECX11L8AAA-_ECX11L8EAA-_ECX11L8BAA-_ECX11L8LAA-_ECX11L8CAA-_ECX11L8DAA-_

XTAE065D00A_XTAE065D00E_XTAE065D00B_XTAE065D00L_XTAE065D00C_XTAE065D00D_

Frame M80 115

208230380460575

7-1/21515———

—2530506075

120208240380/50 Hz480600

ECX11M1AAA-_ECX11M1EAA-_ECX11M1BAA-_ECX11M1LAA-_ECX11M1CAA-_ECX11M1DAA-_

ECX11M4AAA-_ECX11M4EAA-_ECX11M4BAA-_ECX11M4LAA-_ECX11M4CAA-_ECX11M4DAA-_

ECX11M8AAA-_ECX11M8EAA-_ECX11M8BAA-_ECX11M8LAA-_ECX11M8CAA-_ECX11M8DAA-_

XTAE080F00A_XTAE080F00E_XTAE080F00B_XTAE080F00L_XTAE080F00C_XTAE080F00D_

Frame N95 115

208230380460575

7-1/21515———

—25406075

100

120208240380/50 Hz480600

ECX11N1AAA-_ECX11N1EAA-_ECX11N1BAA-_ECX11N1LAA-_ECX11N1CAA-_ECX11N1DAA-_

ECX11N4AAA-_ECX11N4EAA-_ECX11N4BAA-_ECX11N4LAA-_ECX11N4CAA-_ECX11N4DAA-_

ECX11N8AAA-_ECX11N8EAA-_ECX11N8BAA-_ECX11N8LAA-_ECX11N8CAA-_ECX11N8DAA-_

XTAE095F00A_XTAE095F00E_XTAE095F00B_XTAE095F00L_XTAE095F00C_XTAE095F00D_

Frame P115 115

208230380460575

102525———

—405060

100125

120208240380/50 Hz480600

ECX11P1AAA-_ECX11P1EAA-_ECX11P1BAA-_ECX11P1LAA-_ECX11P1CAA-_ECX11P1DAA-_

ECX11P4AAA-_ECX11P4EAA-_ECX11P4BAA-_ECX11P4LAA-_ECX11P4CAA-_ECX11P4DAA-_

ECX11P8AAA-_ECX11P8EAA-_ECX11P8BAA-_ECX11P8LAA-_ECX11P8CAA-_ECX11P8DAA-_

XTAE115G00A_XTAE115G00E_XTAE115G00B_XTAE115G00L_XTAE115G00C_XTAE115G00D_

Frame Q150 115

208230380460575

152530———

—406060

125150

120208240380/50 Hz480600

ECX11Q1AAA-_ECX11Q1EAA-_ECX11Q1BAA-_ECX11Q1LAA-_ECX11Q1CAA-_ECX11Q1DAA-_

ECX11Q4AAA-_ECX11Q4EAA-_ECX11Q4BAA-_ECX11Q4LAA-_ECX11Q4CAA-_ECX11Q4DAA-_

ECX11Q8AAA-_ECX11Q8EAA-_ECX11Q8BAA-_ECX11Q8LAA-_ECX11Q8CAA-_ECX11Q8DAA-_

XTAE150G00A_XTAE150G00E_XTAE150G00B_XTAE150G00L_XTAE150G00C_XTAE150G00D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . . Page 18-19

Page 12: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-12

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-9. Class ECX19 — Combination Non-reversing Starter — Fusible/Non-fusible Disconnect

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX19B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

FuseClips

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame B7 —

115208230380460575

— 1/4 3/4

1———

——1-1/22335

—120208240380/50 Hz480600

30A ECX19B1AAA-_ECX19B1AAC-_ECX19B1EAC-_ECX19B1BAC-_ECX19B1LAC-_ECX19B1CAC-_ECX19B1DAC-_

ECX19B4AAA-_ECX19B4AAC-_ECX19B4EAC-_ECX19B4BAC-_ECX19B4LAC-_ECX19B4CAC-_ECX19B4DAC-_

ECX19B8AAA-_ECX19B8AAC-_ECX19B8EAC-_ECX19B8BAC-_ECX19B8LAC-_ECX19B8CAC-_ECX19B8DAC-_

XTAE007B10A_XTAE007B10A_XTAE007B10E_XTAE007B10B_XTAE007B10L_XTAE007B10C_XTAE007B10D_

Frame C9 —

115208230380460575

— 1/2

11-1/2

———

——23557-1/2

—120208240380/50 Hz480600

30A ECX19C1AAA-_ECX19C1AAC-_ECX19C1EAC-_ECX19C1BAC-_ECX19C1LAC-_ECX19C1CAC-_ECX19C1DAC-_

ECX19C4AAA-_ECX19C4AAC-_ECX19C4EAC-_ECX19C4BAC-_ECX19C4LAC-_ECX19C4CAC-_ECX19C4DAC-_

ECX19C8AAA-_ECX19C8AAC-_ECX19C8EAC-_ECX19C8BAC-_ECX19C8LAC-_ECX19C8CAC-_ECX19C8DAC-_

XTAE009B10A_XTAE009B10A_XTAE009B10E_XTAE009B10B_XTAE009B10L_XTAE009B10C_XTAE009B10D_

Frame D12 —

115208230380460575

— 1/2

1-1/22

———

——3357-1/2

10

—120208240380/50 Hz480600

30A ECX19D1AAA-_ECX19D1AAC-_ECX19D1EAC-_ECX19D1BAC-_ECX19D1LAC-_ECX19D1CAC-_ECX19D1DAC-_

ECX19D4AAA-_ECX19D4AAC-_ECX19D4EAC-_ECX19D4BAC-_ECX19D4LAC-_ECX19D4CAC-_ECX19D4DAC-_

ECX19D8AAA-_ECX19D8AAC-_ECX19D8EAC-_ECX19D8BAC-_ECX19D8LAC-_ECX19D8CAC-_ECX19D8DAC-_

XTAE012B10A_XTAE012B10A_XTAE012B10E_XTAE012B10B_XTAE012B10L_XTAE012B10C_XTAE012B10D_

Frame E15 —

115208230380460575

— 3/4

22

———

——3357-1/2

10

—120208240380/50 Hz480600

30A ECX19E1AAA-_ECX19E1AAC-_ECX19E1EAC-_ECX19E1BAC-_ECX19E1LAC-_ECX19E1CAC-_ECX19E1DAC-_

ECX19E4AAA-_ECX19E4AAC-_ECX19E4EAC-_ECX19E4BAC-_ECX19E4LAC-_ECX19E4CAC-_ECX19E4DAC-_

ECX19E8AAA-_ECX19E8AAC-_ECX19E8EAC-_ECX19E8BAC-_ECX19E8LAC-_ECX19E8CAC-_ECX19E8DAC-_

XTAE015B10A_XTAE015B10A_XTAE015B10E_XTAE015B10B_XTAE015B10L_XTAE015B10C_XTAE015B10D_

Frame F18 —

115208230380460575

—223

———

——557-1/2

1015

—120208240380/50 Hz480600

30A ECX19F1AAA-_ECX19F1AAC-_ECX19F1EAC-_ECX19F1BAC-_ECX19F1LAC-_ECX19F1CAC-_ECX19F1DAC-_

ECX19F4AAA-_ECX19F4AAC-_ECX19F4EAC-_ECX19F4BAC-_ECX19F4LAC-_ECX19F4CAC-_ECX19F4DAC-_

ECX19F8AAA-_ECX19F8AAC-_ECX19F8EAC-_ECX19F8BAC-_ECX19F8LAC-_ECX19F8CAC-_ECX19F8DAC-_

XTAE018C10A_XTAE018C10A_XTAE018C10E_XTAE018C10B_XTAE018C10L_XTAE018C10C_XTAE018C10D_

Frame G25 —

115208230380460575

—235

———

——7-1/27-1/2

101510

—120208240380/50 Hz480600

30A ECX19G1AAA-_ECX19G1AAC-_ECX19G1EAC-_ECX19G1BAC-_ECX19G1LAC-_ECX19G1CAC-_ECX19G1DAC-_

ECX19G4AAA-_ECX19G4AAC-_ECX19G4EAC-_ECX19G4BAC-_ECX19G4LAC-_ECX19G4CAC-_ECX19G4DAC-_

ECX19G8AAA-_ECX19G8AAC-_ECX19G8EAC-_ECX19G8BAC-_ECX19G8LAC-_ECX19G8CAC-_ECX19G8DAC-_

XTAE025C10A_XTAE025C10A_XTAE025C10E_XTAE025C10B_XTAE025C10L_XTAE025C10C_XTAE025C10D_

Frame H32 —

115208230380460575

—355

———

——1010152025

—120208240380/50 Hz480600

60A ECX19H1AAA-_ECX19H1AAE-_ECX19H1EAE-_ECX19H1BAE-_ECX19H1LAE-_ECX19H1CAE-_ECX19H1DAE-_

ECX19H4AAA-_ECX19H4AAE-_ECX19H4EAE-_ECX19H4BAE-_ECX19H4LAE-_ECX19H4CAE-_ECX19H4DAE-_

ECX19H8AAA-_ECX19H8AAE-_ECX19H8EAE-_ECX19H8BAE-_ECX19H8LAE-_ECX19H8CAE-_ECX19H8DAE-_

XTAE032C10A_XTAE032C10A_XTAE032C10E_XTAE032C10B_XTAE032C10L_XTAE032C10C_XTAE032C10D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . Page 18-19

Page 13: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-13IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-9. Class ECX19 — Combination Non-reversing Starter — Fusible/Non-fusible Disconnect (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX19B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.� Non-fused Disconnect only.

Amps Maximum hp � Coil Voltage@ 60 Hz �

FuseClips

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame J40 —

115208230380460575

—357-1/2

———

——1015153040

—120208240380/50 Hz480600

60A ECX19J1AAA-_ECX19J1AAE-_ECX19J1EAE-_ECX19J1BAE-_ECX19J1LAE-_ECX19J1CAE-_ECX19J1DAE-_

ECX19J4AAA-_ECX19J4AAE-_ECX19J4EAE-_ECX19J4BAE-_ECX19J4LAE-_ECX19J4CAE-_ECX19J4DAE-_

ECX19J8AAA-_ECX19J8AAE-_ECX19J8EAE-_ECX19J8BAE-_ECX19J8LAE-_ECX19J8CAE-_ECX19J8DAE-_

XTAE040D00A_XTAE040D00A_XTAE040D00E_XTAE040D00B_XTAE040D00L_XTAE040D00C_XTAE040D00D_

Frame K50 —

115208230380460575

—37-1/2

10———

——1520204050

—120208240380/50 Hz480600

100A ECX19K1AAA-_ECX19K1AAG-_ECX19K1EAG-_ECX19K1BAG-_ECX19K1LAG-_ECX19K1CAG-_ECX19K1DAG-_

ECX19K4AAA-_ECX19K4AAG-_ECX19K4EAG-_ECX19K4BAG-_ECX19K4LAG-_ECX19K4CAG-_ECX19K4DAG-_

ECX19K8AAA-_ECX19K8AAG-_ECX19K8EAG-_ECX19K8BAG-_ECX19K8LAG-_ECX19K8CAG-_ECX19K8DAG-_

XTAE050D00A_XTAE050D00A_XTAE050D00E_XTAE050D00B_XTAE050D00L_XTAE050D00C_XTAE050D00D_

Frame L65 —

115208230380460575

—5

1015———

——2025305060

—120208240380/50 Hz480600

100A ECX19L1AAA-_ECX19L1AAG-_ECX19L1EAG-_ECX19L1BAG-_ECX19L1LAG-_ECX19L1CAG-_ECX19L1DAG-_

ECX19L4AAA-_ECX19L4AAG-_ECX19L4EAG-_ECX19L4BAG-_ECX19L4LAG-_ECX19L4CAG-_ECX19L4DAG-_

ECX19L8AAA-_ECX19L8AAG-_ECX19L8EAG-_ECX19L8BAG-_ECX19L8LAG-_ECX19L8CAG-_ECX19L8DAG-_

XTAE065D00A_XTAE065D00A_XTAE065D00E_XTAE065D00B_XTAE065D00L_XTAE065D00C_XTAE065D00D_

Frame M80 —

115208230380460575

—7-1/2

1515———

——2530506075

—120208240380/50 Hz480600

100A ECX19M1AAA-_ECX19M1AAG-_ECX19M1EAG-_ECX19M1BAG-_ECX19M1LAG-_ECX19M1CAG-_ECX19M1DAG-_

ECX19M4AAA-_ECX19M4AAG-_ECX19M4EAG-_ECX19M4BAG-_ECX19M4LAG-_ECX19M4CAG-_ECX19M4DAG-_

ECX19M8AAA-_ECX19M8AAG-_ECX19M8EAG-_ECX19M8BAG-_ECX19M8LAG-_ECX19M8CAG-_ECX19M8DAG-_

XTAE080F00A_XTAE080F00A_XTAE080F00E_XTAE080F00B_XTAE080F00L_XTAE080F00C_XTAE080F00D_

Frame N �

95 —115208230380460575

—7-1/2

1515———

——25406075

100

—120208240380/50 Hz480600

� ECX19N1AAA-_ECX19N1AAA-_ECX19N1EAA-_ECX19N1BAA-_ECX19N1LAA-_ECX19N1CAA-_ECX19N1DAA-_

ECX19N4AAA-_ECX19N4AAA-_ECX19N4EAA-_ECX19N4BAA-_ECX19N4LAA-_ECX19N4CAA-_ECX19N4DAA-_

ECX19N8AAA-_ECX19N8AAA-_ECX19N8EAA-_ECX19N8BAA-_ECX19N8LAA-_ECX19N8CAA-_ECX19N8DAA-_

XTAE095F00A_XTAE095F00A_XTAE095F00E_XTAE095F00B_XTAE095F00L_XTAE095F00C_XTAE095F00D_

Frame P �

105 —115208230380460575

—102525———

——30406075

100

—120208240380/50 Hz480600

� ECX19P1AAA-_ECX19P1AAA-_ECX19P1EAA-_ECX19P1BAA-_ECX19P1LAA-_ECX19P1CAA-_ECX19P1DAA-_

ECX19P4AAA-_ECX19P4AAA-_ECX19P4EAA-_ECX19P4BAA-_ECX19P4LAA-_ECX19P4CAA-_ECX19P4DAA-_

ECX19P8AAA-_ECX19P8AAA-_ECX19P8EAA-_ECX19P8BAA-_ECX19P8LAA-_ECX19P8CAA-_ECX19P8DAA-_

XTAE115G00A_XTAE115G00A_XTAE115G00E_XTAE115G00B_XTAE115G00L_XTAE115G00C_XTAE115G00D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . . Page 18-19

Page 14: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-14

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-10. Class ECX20 — Combination Reversing Starter — Fusible/Non-fusible Disconnect

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX20B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

FuseClips

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame B7 —

115208230380460575

— 1/4 3/4

1———

——1-1/22335

—120208240380/50 Hz480600

30A ECX20B1AAA-_ECX20B1AAC-_ECX20B1EAC-_ECX20B1BAC-_ECX20B1LAC-_ECX20B1CAC-_ECX20B1DAC-_

ECX20B4AAA-_ECX20B4AAC-_ECX20B4EAC-_ECX20B4BAC-_ECX20B4LAC-_ECX20B4CAC-_ECX20B4DAC-_

ECX20B8AAA-_ECX20B8AAC-_ECX20B8EAC-_ECX20B8BAC-_ECX20B8LAC-_ECX20B8CAC-_ECX20B8DAC-_

XTAR007B10A_XTAR007B10A_XTAR007B10E_XTAR007B10B_XTAR007B10L_XTAR007B10C_XTAR007B10D_

Frame C9 —

115208230380460575

— 1/2

11-1/2

———

——23557-1/2

—120208240380/50 Hz480600

30A ECX20C1AAA-_ECX20C1AAC-_ECX20C1EAC-_ECX20C1BAC-_ECX20C1LAC-_ECX20C1CAC-_ECX20C1DAC-_

ECX20C4AAA-_ECX20C4AAC-_ECX20C4EAC-_ECX20C4BAC-_ECX20C4LAC-_ECX20C4CAC-_ECX20C4DAC-_

ECX20C8AAA-_ECX20C8AAC-_ECX20C8EAC-_ECX20C8BAC-_ECX20C8LAC-_ECX20C8CAC-_ECX20C8DAC-_

XTAR009B10A_XTAR009B10A_XTAR009B10E_XTAR009B10B_XTAR009B10L_XTAR009B10C_XTAR009B10D_

Frame D12 —

115208230380460575

— 1/2

1-1/22

———

——3357-1/2

10

—120208240380/50 Hz480600

30A ECX20D1AAA-_ECX20D1AAC-_ECX20D1EAC-_ECX20D1BAC-_ECX20D1LAC-_ECX20D1CAC-_ECX20D1DAC-_

ECX20D4AAA-_ECX20D4AAC-_ECX20D4EAC-_ECX20D4BAC-_ECX20D4LAC-_ECX20D4CAC-_ECX20D4DAC-_

ECX20D8AAA-_ECX20D8AAC-_ECX20D8EAC-_ECX20D8BAC-_ECX20D8LAC-_ECX20D8CAC-_ECX20D8DAC-_

XTAR012B10A_XTAR012B10A_XTAR012B10E_XTAR012B10B_XTAR012B10L_XTAR012B10C_XTAR012B10D_

Frame E15 —

115208230380460575

— 3/4

22

———

——3357-1/2

10

—120208240380/50 Hz480600

30A ECX20E1AAA-_ECX20E1AAC-_ECX20E1EAC-_ECX20E1BAC-_ECX20E1LAC-_ECX20E1CAC-_ECX20E1DAC-_

ECX20E4AAA-_ECX20E4AAC-_ECX20E4EAC-_ECX20E4BAC-_ECX20E4LAC-_ECX20E4CAC-_ECX20E4DAC-_

ECX20E8AAA-_ECX20E8AAC-_ECX20E8EAC-_ECX20E8BAC-_ECX20E8LAC-_ECX20E8CAC-_ECX20E8DAC-_

XTAR015B10A_XTAR015B10A_XTAR015B10E_XTAR015B10B_XTAR015B10L_XTAR015B10C_XTAR015B10D_

Frame F18 —

115208230380460575

—223

———

——557-1/2

1015

—120208240380/50 Hz480600

30A ECX20F1AAA-_ECX20F1AAC-_ECX20F1EAC-_ECX20F1BAC-_ECX20F1LAC-_ECX20F1CAC-_ECX20F1DAC-_

ECX20F4AAA-_ECX20F4AAC-_ECX20F4EAC-_ECX20F4BAC-_ECX20F4LAC-_ECX20F4CAC-_ECX20F4DAC-_

ECX20F8AAA-_ECX20F8AAC-_ECX20F8EAC-_ECX20F8BAC-_ECX20F8LAC-_ECX20F8CAC-_ECX20F8DAC-_

XTAR018C10A_XTAR018C10A_XTAR018C10E_XTAR018C10B_XTAR018C10L_XTAR018C10C_XTAR018C10D_

Frame G25 —

115208230380460575

—235

———

——7-1/27-1/2

101510

—120208240380/50 Hz480600

30A ECX20G1AAA-_ECX20G1AAC-_ECX20G1EAC-_ECX20G1BAC-_ECX20G1LAC-_ECX20G1CAC-_ECX20G1DAC-_

ECX20G4AAA-_ECX20G4AAC-_ECX20G4EAC-_ECX20G4BAC-_ECX20G4LAC-_ECX20G4CAC-_ECX20G4DAC-_

ECX20G8AAA-_ECX20G8AAC-_ECX20G8EAC-_ECX20G8BAC-_ECX20G8LAC-_ECX20G8CAC-_ECX20G8DAC-_

XTAR025C10A_XTAR025C10A_XTAR025C10E_XTAR025C10B_XTAR025C10L_XTAR025C10C_XTAR025C10D_

Frame H32 —

115208230380460575

—355

———

——1010152025

—120208240380/50 Hz480600

60A ECX20H1AAA-_ECX20H1AAE-_ECX20H1EAE-_ECX20H1BAE-_ECX20H1LAE-_ECX20H1CAE-_ECX20H1DAE-_

ECX20H4AAA-_ECX20H4AAE-_ECX20H4EAE-_ECX20H4BAE-_ECX20H4LAE-_ECX20H4CAE-_ECX20H4DAE-_

ECX20H8AAA-_ECX20H8AAE-_ECX20H8EAE-_ECX20H8BAE-_ECX20H8LAE-_ECX20H8CAE-_ECX20H8DAE-_

XTAR032C10A_XTAR032C10A_XTAR032C10E_XTAR032C10B_XTAR032C10L_XTAR032C10C_XTAR032C10D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . Page 18-19

Page 15: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-15IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-10. Class ECX20 — Combination Reversing Starter — Fusible/Non-fusible Disconnect (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX20B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.� Non-fused Disconnect only.

Amps Maximum hp � Coil Voltage@ 60 Hz �

FuseClips

Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame J40 —

115208230380460575

—357-1/2

———

——1015153040

—120208240380/50 Hz480600

60A ECX20J1AAA-_ECX20J1AAE-_ECX20J1EAE-_ECX20J1BAE-_ECX20J1LAE-_ECX20J1CAE-_ECX20J1DAE-_

ECX20J4AAA-_ECX20J4AAE-_ECX20J4EAE-_ECX20J4BAE-_ECX20J4LAE-_ECX20J4CAE-_ECX20J4DAE-_

ECX20J8AAA-_ECX20J8AAE-_ECX20J8EAE-_ECX20J8BAE-_ECX20J8LAE-_ECX20J8CAE-_ECX20J8DAE-_

XTAR040D00A_XTAR040D00A_XTAR040D00E_XTAR040D00B_XTAR040D00L_XTAR040D00C_XTAR040D00D_

Frame K50 —

115208230380460575

—37-1/2

10———

——1520204050

—120208240380/50 Hz480600

100A ECX20K1AAA-_ECX20K1AAG-_ECX20K1EAG-_ECX20K1BAG-_ECX20K1LAG-_ECX20K1CAG-_ECX20K1DAG-_

ECX20K4AAA-_ECX20K4AAG-_ECX20K4EAG-_ECX20K4BAG-_ECX20K4LAG-_ECX20K4CAG-_ECX20K4DAG-_

ECX20K8AAA-_ECX20K8AAG-_ECX20K8EAG-_ECX20K8BAG-_ECX20K8LAG-_ECX20K8CAG-_ECX20K8DAG-_

XTAR050D00A_XTAR050D00A_XTAR050D00E_XTAR050D00B_XTAR050D00L_XTAR050D00C_XTAR050D00D_

Frame L65 —

115208230380460575

—5

1015———

——2025305060

—120208240380/50 Hz480600

100A ECX20L1AAA-_ECX20L1AAG-_ECX20L1EAG-_ECX20L1BAG-_ECX20L1LAG-_ECX20L1CAG-_ECX20L1DAG-_

ECX20L4AAA-_ECX20L4AAG-_ECX20L4EAG-_ECX20L4BAG-_ECX20L4LAG-_ECX20L4CAG-_ECX20L4DAG-_

ECX20L8AAA-_ECX20L8AAG-_ECX20L8EAG-_ECX20L8BAG-_ECX20L8LAG-_ECX20L8CAG-_ECX20L8DAG-_

XTAR065D00A_XTAR065D00A_XTAR065D00E_XTAR065D00B_XTAR065D00L_XTAR065D00C_XTAR065D00D_

Frame M80 —

115208230380460575

—7-1/2

1515———

——2530506075

—120208240380/50 Hz480600

100A ECX20M1AAA-_ECX20M1AAG-_ECX20M1EAG-_ECX20M1BAG-_ECX20M1LAG-_ECX20M1CAG-_ECX20M1DAG-_

ECX20M4AAA-_ECX20M4AAG-_ECX20M4EAG-_ECX20M4BAG-_ECX20M4LAG-_ECX20M4CAG-_ECX20M4DAG-_

ECX20M8AAA-_ECX20M8AAG-_ECX20M8EAG-_ECX20M8BAG-_ECX20M8LAG-_ECX20M8CAG-_ECX20M8DAG-_

XTAR080F00A_XTAR080F00A_XTAR080F00E_XTAR080F00B_XTAR080F00L_XTAR080F00C_XTAR080F00D_

Frame N �

95 —115208230380460575

—7-1/2

1515———

——25406075

100

—120208240380/50 Hz480600

� ECX20N1AAA-_ECX20N1AAA-_ECX20N1EAA-_ECX20N1BAA-_ECX20N1LAA-_ECX20N1CAA-_ECX20N1DAA-_

ECX20N4AAA-_ECX20N4AAA-_ECX20N4EAA-_ECX20N4BAA-_ECX20N4LAA-_ECX20N4CAA-_ECX20N4DAA-_

ECX20N8AAA-_ECX20N8AAA-_ECX20N8EAA-_ECX20N8BAA-_ECX20N8LAA-_ECX20N8CAA-_ECX20N8DAA-_

XTAR095F00A_XTAR095F00A_XTAR095F00E_XTAR095F00B_XTAR095F00L_XTAR095F00C_XTAR095F00D_

Frame P �

105 —115208230380460575

—102525———

——30406075

100

—120208240380/50 Hz480600

� ECX20P1AAA-_ECX20P1AAA-_ECX20P1EAA-_ECX20P1BAA-_ECX20P1LAA-_ECX20P1CAA-_ECX20P1DAA-_

ECX20P4AAA-_ECX20P4AAA-_ECX20P4EAA-_ECX20P4BAA-_ECX20P4LAA-_ECX20P4CAA-_ECX20P4DAA-

ECX20P8AAA-_ECX20P8AAA-_ECX20P8EAA-_ECX20P8BAA-_ECX20P8LAA-_ECX20P8CAA-_ECX20P8DAA-_

XTAR115G00A_XTAR115G00A_XTAR115G00E_XTAR115G00B_XTAR115G00L_XTAR115G00C_XTAR115G00D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . . Page 18-19

Page 16: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-16

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-11. Class ECX25 — Combination Non-reversing Starter — Circuit Breaker

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX25B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

HMCP Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame B7 115

208230380460575

1/4 3/4

1———

—1-1/22335

120208240380/50 Hz480600

7A ECX25B1AAC-_ECX25B1EAC-_ECX25B1BAC-_ECX25B1LAC-_ECX25B1CAC-_ECX25B1DAC-_

ECX25B4AAC-_ECX25B4EAC-_ECX25B4BAC-_ECX25B4LAC-_ECX25B4CAC-_ECX25B4DAC-_

ECX25B8AAC-_ECX25B8EAC-_ECX25B8BAC-_ECX25B8LAC-_ECX25B8CAC-_ECX25B8DAC-_

XTAE007B10A_XTAE007B10E_XTAE007B10B_XTAE007B10L_XTAE007B10C_XTAE007B10D_

Frame C9 115

208230380460575

1/211-1/2

———

—23557-1/2

120208240380/50 Hz480600

15A ECX25C1AAD-_ECX25C1EAD-_ECX25C1BAD-_ECX25C1LAD-_ECX25C1CAD-_ECX25C1DAD-_

ECX25C4AAD-_ECX25C4EAD-_ECX25C4BAD-_ECX25C4LAD-_ECX25C4CAD-_ECX25C4DAD-_

ECX25C8AAD-_ECX25C8EAD-_ECX25C8BAD-_ECX25C8LAD-_ECX25C8CAD-_ECX25C8DAD-_

XTAE009B10A_XTAE009B10E_XTAE009B10B_XTAE009B10L_XTAE009B10C_XTAE009B10D_

Frame D12 115

208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

15A ECX25D1AAD-_ECX25D1EAD-_ECX25D1BAD-_ECX25D1LAD-_ECX25D1CAD-_ECX25D1DAD-_

ECX25D4AAD-_ECX25D4EAD-_ECX25D4BAD-_ECX25D4LAD-_ECX25D4CAD-_ECX25D4DAD-_

ECX25D8AAD-_ECX25D8EAD-_ECX25D8BAD-_ECX25D8LAD-_ECX25D8CAD-_ECX25D8DAD-_

XTAE012B10A_XTAE012B10E_XTAE012B10B_XTAE012B10L_XTAE012B10C_XTAE012B10D_

Frame E15 115

208230380460575

3/422

———

—3357-1/2

10

120208240380/50 Hz480600

30A ECX25E1AAE-_ECX25E1EAE-_ECX25E1BAE-_ECX25E1LAE-_ECX25E1CAE-_ECX25E1DAE-_

ECX25E4AAE-_ECX25E4EAE-_ECX25E4BAE-_ECX25E4LAE-_ECX25E4CAE-_ECX25E4DAE-_

ECX25E8AAE-_ECX25E8EAE-_ECX25E8BAE-_ECX25E8LAE-_ECX25E8CAE-_ECX25E8DAE-_

XTAE015B10A_XTAE015B10E_XTAE015B10B_XTAE015B10L_XTAE015B10C_XTAE015B10D_

Frame F18 115

208230380460575

223

———

—557-1/2

1015

120208240380/50 Hz480600

30A ECX25F1AAE-_ECX25F1EAE-_ECX25F1BAE-_ECX25F1LAE-_ECX25F1CAE-_ECX25F1DAE-_

ECX25F4AAE-_ECX25F4EAE-_ECX25F4BAE-_ECX25F4LAE-_ECX25F4CAE-_ECX25F4DAE-_

ECX25F8AAE-_ECX25F8EAE-_ECX25F8BAE-_ECX25F8LAE-_ECX25F8CAE-_ECX25F8DAE-_

XTAE018C10A_XTAE018C10E_XTAE018C10B_XTAE018C10L_XTAE018C10C_XTAE018C10D_

Frame G25 115

208230380460575

235

———

—7-1/27-1/2

101510

120208240380/50 Hz480600

50A ECX25G1AAF-_ECX25G1EAF-_ECX25G1BAF-_ECX25G1LAF-_ECX25G1CAF-_ECX25G1DAF-_

ECX25G4AAF-_ECX25G4EAF-_ECX25G4BAF-_ECX25G4LAF-_ECX25G4CAF-_ECX25G4DAF-_

ECX25G8AAF-_ECX25G8EAF-_ECX25G8BAF-_ECX25G8LAF-_ECX25G8CAF-_ECX25G8DAF-_

XTAE025C10A_XTAE025C10E_XTAE025C10B_XTAE025C10L_XTAE025C10C_XTAE025C10D_

Frame H32 115

208230380460575

355

———

—1010152025

120208240380/50 Hz480600

50A ECX25H1AAF-_ECX25H1EAF-_ECX25H1BAF-_ECX25H1LAF-_ECX25H1CAF-_ECX25H1DAF-_

ECX25H4AAF-_ECX25H4EAF-_ECX25H4BAF-_ECX25H4LAF-_ECX25H4CAF-_ECX25H4DAF-_

ECX25H8AAF-_ECX25H8EAF-_ECX25H8BAF-_ECX25H8LAF-_ECX25H8CAF-_ECX25H8DAF-_

XTAE032C10A_XTAE032C10E_XTAE032C10B_XTAE032C10L_XTAE032C10C_XTAE032C10D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . Page 18-19

Page 17: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-17IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-11. Class ECX25 — Combination Non-reversing Starter — Circuit Breaker (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX25B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

HMCP Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame J40 115

208230380460575

357-1/2

———

—1015153040

120208240380/50 Hz480600

50A ECX25J1AAF-_ECX25J1EAF-_ECX25J1BAF-_ECX25J1LAF-_ECX25J1CAF-_ECX25J1DAF-_

ECX25J4AAF-_ECX25J4EAF-_ECX25J4BAF-_ECX25J4LAF-_ECX25J4CAF-_ECX25J4DAF-_

ECX25J8AAF-_ECX25J8EAF-_ECX25J8BAF-_ECX25J8LAF-_ECX25J8CAF-_ECX25J8DAF-_

XTAE040D00A_XTAE040D00E_XTAE040D00B_XTAE040D00L_XTAE040D00C_XTAE040D00D_

Frame K50 115

208230380460575

37-1/2

10———

—1520204050

120208240380/50 Hz480600

70A ECX25K1AAW-_ECX25K1EAW-_ECX25K1BAW-_ECX25K1LAW-_ECX25K1CAW-_ECX25K1DAW-_

ECX25K4AAW-_ECX25K4EAW-_ECX25K4BAW-_ECX25K4LAW-_ECX25K4CAW-_ECX25K4DAW-_

ECX25K8AAW-_ECX25K8EAW-_ECX25K8BAW-_ECX25K8LAW-_ECX25K8CAW-_ECX25K8DAW-_

XTAE050D00A_XTAE050D00E_XTAE050D00B_XTAE050D00L_XTAE050D00C_XTAE050D00D_

Frame L65 115

208230380460575

51015———

—2025305060

120208240380/50 Hz480600

70A ECX25L1AAW-_ECX25L1EAW-_ECX25L1BAW-_ECX25L1LAW-_ECX25L1CAW-_ECX25L1DAW-_

ECX25L4AAW-_ECX25L4EAW-_ECX25L4BAW-_ECX25L4LAW-_ECX25L4CAW-_ECX25L4DAW-_

ECX25L8AAW-_ECX25L8EAW-_ECX25L8BAW-_ECX25L8LAW-_ECX25L8CAW-_ECX25L8DAW-_

XTAE065D00A_XTAE065D00E_XTAE065D00B_XTAE065D00L_XTAE065D00C_XTAE065D00D_

Frame M80 115

208230380460575

7-1/21515———

—2530506075

120208240380/50 Hz480600

100A ECX25M1AAG-_ECX25M1EAG-_ECX25M1BAG-_ECX25M1LAG-_ECX25M1CAG-_ECX25M1DAG-_

ECX25M4AAG-_ECX25M4EAG-_ECX25M4BAG-_ECX25M4LAG-_ECX25M4CAG-_ECX25M4DAG-_

ECX25M8AAG-_ECX25M8EAG-_ECX25M8BAG-_ECX25M8LAG-_ECX25M8CAG-_ECX25M8DAG-_

XTAE080F00A_XTAE080F00E_XTAE080F00B_XTAE080F00L_XTAE080F00C_XTAE080F00D_

Frame N95 115

208230380460575

7-1/21515———

—25406075

100

120208240380/50 Hz480600

100A ECX25N1AAG-_ECX25N1EAG-_ECX25N1BAG-_ECX25N1LAG-_ECX25N1CAG-_ECX25N1DAG-_

ECX25N4AAG-_ECX25N4EAG-_ECX25N4BAG-_ECX25N4LAG-_ECX25N4CAG-_ECX25N4DAG-_

ECX25N8AAG-_ECX25N8EAG-_ECX25N8BAG-_ECX25N8LAG-_ECX25N8CAG-_ECX25N8DAG-_

XTAE095F00A_XTAE095F00E_XTAE095F00B_XTAE095F00L_XTAE095F00C_XTAE095F00D_

Frame P115 115

208230380460575

102525———

—405060

100125

120208240380/50 Hz480600

150A ECX25P1AAH-_ECX25P1EAH-_ECX25P1BAH-_ECX25P1LAH-_ECX25P1CAH-_ECX25P1DAH-_

ECX25P4AAH-_ECX25P4EAH-_ECX25P4BAH-_ECX25P4LAH-_ECX25P4CAH-_ECX25P4DAH-_

ECX25P8AAH-_ECX25P8EAH-_ECX25P8BAH-_ECX25P8LAH-_ECX25P8CAH-_ECX25P8DAH-_

XTAE115G00A_XTAE115G00E_XTAE115G00B_XTAE115G00L_XTAE115G00C_XTAE115G00D_

Frame Q125 115

208230380460575

152525———

—405075

100125

120208240380/50 Hz480600

150A ECX25Q1AAH-_ECX25Q1EAH-_ECX25Q1BAH-_ECX25Q1LAH-_ECX25Q1CAH-_ECX25Q1DAH-_

ECX25Q4AAH-_ECX25Q4EAH-_ECX25Q4BAH-_ECX25Q4LAH-_ECX25Q4CAH-_ECX25Q4DAH-_

ECX25Q8AAH-_ECX25Q8EAH-_ECX25Q8BAH-_ECX25Q8LAH-_ECX25Q8CAH-_ECX25Q8DAH-_

XTAE150G00A_XTAE150G00E_XTAE150G00B_XTAE150G00L_XTAE150G00C_XTAE150G00D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . . Page 18-19

Page 18: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-18

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-12. Class ECX26 — Combination Reversing Starter — Circuit Breaker

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX26B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

HMCP Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame B7 115

208230380460575

1/4 3/4

1———

—1-1/22335

120208240380/50 Hz480600

7A ECX26B1AAC-_ECX26B1EAC-_ECX26B1BAC-_ECX26B1LAC-_ECX26B1CAC-_ECX26B1DAC-_

ECX26B4AAC-_ECX26B4EAC-_ECX26B4BAC-_ECX26B4LAC-_ECX26B4CAC-_ECX26B4DAC-_

ECX26B8AAC-_ECX26B8EAC-_ECX26B8BAC-_ECX26B8LAC-_ECX26B8CAC-_ECX26B8DAC-_

XTAR007B10A_XTAR007B10E_XTAR007B10B_XTAR007B10L_XTAR007B10C_XTAR007B10D_

Frame C9 115

208230380460575

1/211-1/2

———

—23557-1/2

120208240380/50 Hz480600

15A ECX26C1AAD-_ECX26C1EAD-_ECX26C1BAD-_ECX26C1LAD-_ECX26C1CAD-_ECX26C1DAD-_

ECX26C4AAD-_ECX26C4EAD-_ECX26C4BAD-_ECX26C4LAD-_ECX26C4CAD-_ECX26C4DAD-_

ECX26C8AAD-_ECX26C8EAD-_ECX26C8BAD-_ECX26C8LAD-_ECX26C8CAD-_ECX26C8DAD-_

XTAR009B10A_XTAR009B10E_XTAR009B10B_XTAR009B10L_XTAR009B10C_XTAR009B10D_

Frame D12 115

208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

15A ECX26D1AAD-_ECX26D1EAD-_ECX26D1BAD-_ECX26D1LAD-_ECX26D1CAD-_ECX26D1DAD-_

ECX26D4AAD-_ECX26D4EAD-_ECX26D4BAD-_ECX26D4LAD-_ECX26D4CAD-_ECX26D4DAD-_

ECX26D8AAD-_ECX26D8EAD-_ECX26D8BAD-_ECX26D8LAD-_ECX26D8CAD-_ECX26D8DAD-_

XTAR012B10A_XTAR012B10E_XTAR012B10B_XTAR012B10L_XTAR012B10C_XTAR012B10D_

Frame E15 115

208230380460575

3/422

———

—3357-1/2

10

120208240380/50 Hz480600

30A ECX26E1AAE-_ECX26E1EAE-_ECX26E1BAE-_ECX26E1LAE-_ECX26E1CAE-_ECX26E1DAE-_

ECX26E4AAE-_ECX26E4EAE-_ECX26E4BAE-_ECX26E4LAE-_ECX26E4CAE-_ECX26E4DAE-_

ECX26E8AAE-_ECX26E8EAE-_ECX26E8BAE-_ECX26E8LAE-_ECX26E8CAE-_ECX26E8DAE-_

XTAR015B10A_XTAR015B10E_XTAR015B10B_XTAR015B10L_XTAR015B10C_XTAR015B10D_

Frame F18 115

208230380460575

223

———

—557-1/2

1015

120208240380/50 Hz480600

30A ECX26F1AAE-_ECX26F1EAE-_ECX26F1BAE-_ECX26F1LAE-_ECX26F1CAE-_ECX26F1DAE-_

ECX26F4AAE-_ECX26F4EAE-_ECX26F4BAE-_ECX26F4LAE-_ECX26F4CAE-_ECX26F4DAE-_

ECX26F8AAE-_ECX26F8EAE-_ECX26F8BAE-_ECX26F8LAE-_ECX26F8CAE-_ECX26F8DAE-_

XTAR018C10A_XTAR018C10E_XTAR018C10B_XTAR018C10L_XTAR018C10C_XTAR018C10D_

Frame G25 115

208230380460575

235

———

—7-1/27-1/2

101510

120208240380/50 Hz480600

50A ECX26G1AAF-_ECX26G1EAF-_ECX26G1BAF-_ECX26G1LAF-_ECX26G1CAF-_ECX26G1DAF-_

ECX26G4AAF-_ECX26G4EAF-_ECX26G4BAF-_ECX26G4LAF-_ECX26G4CAF-_ECX26G4DAF-_

ECX26G8AAF-_ECX26G8EAF-_ECX26G8BAF-_ECX26G8LAF-_ECX26G8CAF-_ECX26G8DAF-_

XTAR025C10A_XTAR025C10E_XTAR025C10B_XTAR025C10L_XTAR025C10C_XTAR025C10D_

Frame H32 115

208230380460575

355

———

—1010152025

120208240380/50 Hz480600

50A ECX26H1AAF-_ECX26H1EAF-_ECX26H1BAF-_ECX26H1LAF-_ECX26H1CAF-_ECX26H1DAF-_

ECX26H4AAF-_ECX26H4EAF-_ECX26H4BAF-_ECX26H4LAF-_ECX26H4CAF-_ECX26H4DAF-_

ECX26H8AAF-_ECX26H8EAF-_ECX26H8BAF-_ECX26H8LAF-_ECX26H8CAF-_ECX26H8DAF-_

XTAR032C10A_XTAR032C10E_XTAR032C10B_XTAR032C10L_XTAR032C10C_XTAR032C10D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . Page 18-19

Page 19: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-19IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Table 4-12. Class ECX26 — Combination Reversing Starter — Circuit Breaker (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTOB” Overload Amperage range as per motor FLA, see Table 4-2.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX26B4AAA-_. To order Type 4X

316-Grade Stainless Steel, change that digit to 9. To order Type 4 Painted Steel, change that digit to 3. To order Nonmetallic, change that digit to 5. For details on these Alternate Enclosures, see Tab 14.

� Contact factory for other voltage options.

Amps Maximum hp � Coil Voltage@ 60 Hz �

HMCP Type 1/IP23 Type 4X/IP66 � Type 12/IP65 Component

MotorVoltage �

1-Phase 3-Phase CatalogNumber �

CatalogNumber �

CatalogNumber �

CatalogNumber �

Frame J40 115

208230380460575

357-1/2

———

—1015153040

120208240380/50 Hz480600

50A ECX26J1AAF-_ECX26J1EAF-_ECX26J1BAF-_ECX26J1LAF-_ECX26J1CAF-_ECX26J1DAF-_

ECX26J4AAF-_ECX26J4EAF-_ECX26J4BAF-_ECX26J4LAF-_ECX26J4CAF-_ECX26J4DAF-_

ECX26J8AAF-_ECX26J8EAF-_ECX26J8BAF-_ECX26J8LAF-_ECX26J8CAF-_ECX26J8DAF-_

XTAR040D00A_XTAR040D00E_XTAR040D00B_XTAR040D00L_XTAR040D00C_XTAR040D00D_

Frame K50 115

208230380460575

37-1/2

10———

—1520204050

120208240380/50 Hz480600

70A ECX26K1AAW-_ECX26K1EAW-_ECX26K1BAW-_ECX26K1LAW-_ECX26K1CAW-_ECX26K1DAW-_

ECX26K4AAW-_ECX26K4EAW-_ECX26K4BAW-_ECX26K4LAW-_ECX26K4CAW-_ECX26K4DAW-_

ECX26K8AAW-_ECX26K8EAW-_ECX26K8BAW-_ECX26K8LAW-_ECX26K8CAW-_ECX26K8DAW-_

XTAR050D00A_XTAR050D00E_XTAR050D00B_XTAR050D00L_XTAR050D00C_XTAR050D00D_

Frame L65 115

208230380460575

51015———

—2025305060

120208240380/50 Hz480600

100A ECX26L1AAW-_ECX26L1EAW-_ECX26L1BAW-_ECX26L1LAW-_ECX26L1CAW-_ECX26L1DAW-_

ECX26L4AAW-_ECX26L4EAW-_ECX26L4BAW-_ECX26L4LAW-_ECX26L4CAW-_ECX26L4DAW-_

ECX26L8AAW-_ECX26L8EAW-_ECX26L8BAW-_ECX26L8LAW-_ECX26L8CAW-_ECX26L8DAW-_

XTAR065D00A_XTAR065D00E_XTAR065D00B_XTAR065D00L_XTAR065D00C_XTAR065D00D_

Frame M80 115

208230380460575

7-1/21515———

—2530506075

120208240380/50 Hz480600

100A ECX26M1AAG-_ECX26M1EAG-_ECX26M1BAG-_ECX26M1LAG-_ECX26M1CAG-_ECX26M1DAG-_

ECX26M4AAG-_ECX26M4EAG-_ECX26M4BAG-_ECX26M4LAG-_ECX26M4CAG-_ECX26M4DAG-_

ECX26M8AAG-_ECX26M8EAG-_ECX26M8BAG-_ECX26M8LAG-_ECX26M8CAG-_ECX26M8DAG-_

XTAR080F00A_XTAR080F00E_XTAR080F00B_XTAR080F00L_XTAR080F00C_XTAR080F00D_

Frame N95 115

208230380460575

7-1/21515———

—25406075

100

120208240380/50 Hz480600

100A ECX26N1AAG-_ECX26N1EAG-_ECX26N1BAG-_ECX26N1LAG-_ECX26N1CAG-_ECX26N1DAG-_

ECX26N4AAG-_ECX26N4EAG-_ECX26N4BAG-_ECX26N4LAG-_ECX26N4CAG-_ECX26N4DAG-_

ECX26N8AAG-_ECX26N8EAG-_ECX26N8BAG-_ECX26N8LAG-_ECX26N8CAG-_ECX26N8DAG-_

XTAR095F00A_XTAR095F00E_XTAR095F00B_XTAR095F00L_XTAR095F00C_XTAR095F00D_

Frame P115 115

208230380460575

102525———

—405060

100125

120208240380/50 Hz480600

150A ECX26P1AAH-_ECX26P1EAH-_ECX26P1BAH-_ECX26P1LAH-_ECX26P1CAH-_ECX26P1DAH-_

ECX26P4AAH-_ECX26P4EAH-_ECX26P4BAH-_ECX26P4LAH-_ECX26P4CAH-_ECX26P4DAH-_

ECX26P8AAH-_ECX26P8EAH-_ECX26P8BAH-_ECX26P8LAH-_ECX26P8CAH-_ECX26P8DAH-_

XTAR115G00A_XTAR115G00E_XTAR115G00B_XTAR115G00L_XTAR115G00C_XTAR115G00D_

Cover Control . . . . . . . . . . . . . . . . . . . Page 4-4Wiring Diagrams . . . . . . . . . . . . . . . . Page 4-20Dimensions . . . . . . . . . . . . . . . . . . . . . Page 15-5Accessories . . . . . . . . . . . . . . . . . . . . Page 16-23Modification Codes . . . . . . . . . . . . . . Page 16-40Technical Data . . . . . . . . . . . . . . . . . . Page 18-19

Page 20: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-20

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Wiring Diagrams

Figure 4-1. Typical Wiring Diagram

01

03

02

1 96

L3

L1

L2

M OL

01

03

02

L3

L1

L2

M OL

MotorT3

T2

T1

Stop

61

1

9897

OverloadTripped

A2

3/42/3

62/7M

OL

M

Start

MotorStopped

A1M

MotorRun

96OL95

Auto

RemoteAuto

Contact

1 2/3OFF

Hand

M3/4

A1M

A2

With 3-Position Selector SwitchFVNR with Pushbutton Control

Control Power Transformer Option

02

03

01

L2

L3

L1OLF

R

Motor

T1

T3

T2

Stop

1

4

1B

2

R5

F3

Rev

A1

(If Used)

7

RLS F

6

RA2

RevFor

A1FLS R

Fwd

A2F

95OL96

1OFF

Rev5

3-Position Switch

Fwd3

1

Hand

Auto

Remote

Fwd

Rev

OFF

1B

5

3

2- and 3-Position Switch

Reversing Combination Starter Wiring

Page 21: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-21IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Figure 4-2. Typical Wiring Diagram — Non-combination Starters (Non-reversing)

Remote Pilot Devices Connections for Non-reversing Starter

2-Wire Control

3/141

2/133/14

1

2/13

3/14

1

Not for Use with Auto Reset OL Relays

3-Wire Control

Start

When More Than One Pushbutton Station is Used, Omit Connector“A” and Connect per

Sketch Below

Stop

Start

“A”

Stop Stop

Start

Separate Control

Remove Wire “C” if Suppliedand Connect Separate Control

Lines to the Number 1 Terminalon the Remote Pilot Device

and to the Number 96 Terminalon the Overload Relay.

AC Lines

1L1

A1 A2

3L2

5L3

“C”

1

M

OL

2/T1

4/T2

6/T3

2/13

3/14

98

Figure 1Front View of Panel

9796

Reset

95

T12

T1 T2 T3 T1 T2

T24

T36

T24

Conversion to1-Phase — Add

Dotted LineConnections.

3-PhaseMotor

1-PhaseMotor

Local Control Options (If Used)Full Voltage Non-reversing Starters

Figure A START/STOP PushbuttonsYellow

2/13 Start

Black3/14 3 4

RedStop Red

1 1 2

Figure B START/STOP Selector Switch

3 1

4 2

BlackStart

Red

3

1

Figure C 3-PositionSelector Switch

YellowHand To Coil

RemoteSwitch

BlackAuto3

4

3

4

1Red

To Coil

Figure D 2-PositonSelector Switch

YellowHand

Black

Auto

Red 1

1 3

2 4

Figure E Pilot Light(Motor RUN)

Connect to CoilTerminals “A1” & “A2”

Black/White X1

X2

Black/White

Figure F Pilot Light(Motor Stop)

Connect to NC Interlock

Black/White X1

X2Connect to OLTerminal No. 96

Black/White

Figure G OverloadTripped

Black/White

Black/White

X1

X2

198

97

96Reset95

OL

Wire “C”

Page 22: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-22

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlContactors and Starters

Figure 4-3. Typical Wiring Diagram — Non-combination Starters (Reversing)

Remote ControlStations

SPDTSwitch

For3

1

5Rev

Rev

For31

5

Hold DownPushbutton

324

5

1

Pushbutton

For

Rev

Stop

Pushbutton with FOR and REV Buttons

Electrically Interlocked

For

23

45

1

Rev

Stop

Figure 1Front View of Panel

ACLines 3 2

1 3 5L1 L2 L3

53

54

61

62

C320KGT5AuxiliaryContact

53

54

61

62

Wire “F” – Usedwith LocalControlPushbuttons

5 4

A1

F

A2

1

A1 A2

R

OL

98

9796

“C”

Reset

952T1

4T2

6T3

T12

T24

T36

T1 T2 T3

ACMotor

Separate Control

Remove Wire “C” if Suppliedand Connect Separate Control

Lines to the Number 1 Terminalon the Remote Pilot Device andto the Number 96 Terminal on

the Overload Relay.

“C”

Reversing Starter Elementary Diagram

L1 L2 L3Lines Contactors “F” and “R” are

Mechanically Interlocked

F

R

F

R

F

R

OL

OL

OL

ACMotor

Stop Rev. For.

1 2

4

53 54

F3 62 61 95 96

F

R

A1 R A25 62 61

R A1 F A2 OL

53 54

T1

T2T3

Page 23: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-23IEC Contactors & Starters

4

XT IEC Power ControlCombination Motor Controllers

Product DescriptionEaton’s Cutler-Hammer® XT Lineincludes IEC Contactors, Starters and Combination Motor Controllers (CMCs). Designed to meet International Standards, the Enclosed Control XTLine (ECX) carries UL and cUL certifications.

Features and Benefits■ ON/OFF rotary handle with lockout

provision■ Visible trip indication■ Test trip function■ Motor applications from 0.11A to

32A■ Class 10 overload protection■ Built-in heater and magnetic trip

elements to protect the motor■ Phase loss sensitivity■ Type 2 coordination■ Ambient compensated up to 55°C

[140°F]■ Control inputs located at front of

starter for easy access and wiring■ Wide range of coils■ DIN Rail mount — XTSC…BB_■ Mounting plates — XTSC…BC_,

XTSC…D motor controllers■ Adjustment dial for setting motor

FLA■ Short circuit trip at 14 times the

maximum setting of the FLA adjustment dial

■ UL 508 Type F CMC High Fault Short Circuit Ratings: Refer to Manual Motor Protectors in CA08102001E.

■ Nonmetallic and metallic enclosures in Types 1 (IP23), 4 (IP66), 4X (IP66) and 12 (IP65)

■ Opaque (standard) or clear covers available on nonmetallic Halyester enclosure

Short Circuit Ratings■ 0 – 12A/B-frame MMP with B-frame

contactor❑ 50K AIC @ 600V

■ 13 – 32A/B-frame MMP with C-frame contactor❑ 18K AIC @ 600V

Standards and CertificationsNote: See Page 18-2 for additional informa-tion on Standards and Certifications that apply to all Cutler-Hammer Enclosed Control products.

■ UL Listed■ cUL Listed (indicates appropriate

CSA Standard investigation)

Enclosed XT CMC

Page 24: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-24

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlCombination Motor Controllers

Catalog Number SelectionTable 4-13. Combination Motor Controllers — Enclosed Control Catalog Numbering System

� See Table 1-2 on Page 1-4 for Enclosure Type/IP Rating Cross-Reference.

Table 4-14. XTPR MMP Amperage Ranges

E C X 7 6 D 4 B A A -

Design

X = XT IEC

Disconnect Ratings

A = None

Modification Codes

See Page 16-40

MMP Overload Range

See Table 4-14

Frame Size

D =H =

12A32A

Enclosure Type/IP Ratings �

1 =3 =4 =5 =8 =

Type 1 — General PurposeType 4 — Painted SteelType 4X — Watertight (304-Grade SS)Type 4X — Watertight NonmetallicType 12 — Dust-Tight

Coil Voltage

A =B =C =D =E =L =

120V240V480V600V208V380V/50 Hz

Class Table

76 = Combination Motor Controller (CMC) — Non-reversing Starter

4-17

77 = Combination Motor Controller (CMC) — Non-reversing Starter with CPT

4-18

78 = Combination Motor Controller (CMC) — Reversing Starter

4-19

Cover Control

See Table 4-15

XT MMPCatalog Number

OverloadAmp Range

Enclosed Control Suffix Code

Frame B Rotary MMPXTPRP16BC1 .1 – .16 A

XTPRP25BC1 .16 – .25 B

XTPRP40BC1 .25 – .4 C

XTPRP63BC1 .4 – .63 D

XTPR001BC1 .63 – 1 E

XTPR1P6BC1 1 – 1.6 F

XTPR2P5BC1 1.6 – 2.5 G

XTPR004BC1 2.5 – 4 H

XTPR6P3BC1 4 – 6.3 J

XTPR010BC1 6.3 – 10 K

XTPR012BC1 8 – 12.0 L

XTPR016BC1 10 – 16.0 M

XTPR020BC1 16 – 20 N

XTPR025BC1 20 – 25 Q

XTPR032BC1 25 – 32 R

Page 25: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-25IEC Contactors & Starters

4

XT IEC Power ControlCombination Motor Controllers

Cover Control■ Cover control for Combination Motor

Control Starters uses the 10250T (30 mm) family.

■ E22 style cover control is an avail-able option

■ Selector switches are maintained with lever operators.

■ Pushbuttons are momentary type with extended pushbutton.

■ The kit includes hardware and connecting wires (where possible).

■ For factory installed control devices other than shown below, refer to Modification Codes, Page 16-40.

Table 4-15. 10250T Style Combination Cover Control

� Add Code Letter from the table below to Catalog Number for voltage — Kits only. Example: C400T9B.

� Order Quantity (2) of C400T10.

Description Factory Installed Flange Control

Field Installation Kits

Position9 Alpha

Combination

CatalogNumber

Non-reversingNo Cover Mounted Pilot DevicesSTART/STOP Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

ABCD

—C400T1——

ON/OFF Pushbuttonswith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

EFG

C400T2——

HAND/OFF/AUTO Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

HJK

C400T12——

START PushbuttonON PushbuttonOFF PushbuttonRed RUN Pilot LightGreen OFFRed RUN/Green OFF Pilot Lights

LMNPQR

C400T3C400T4C400T5C400T9 �

C400T10 �

C400T11 �

START/STOP Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

STU

C400T13——

ON/OFF Selector Switchwith Red RUN Pilot Lightwith Red RUN/Green OFF Lights

VWX

C400T14——

ReversingNo Cover Mounted Pilot DevicesFOR/REV/STOP Pushbuttonswith 2 Red Pilot Lightswith 2 Red/1 Green Pilot Lights

ABCD

—C400T6——

UP/STOP/DOWN Pushbuttonswith 2 Red Pilot Lights

EF

——

FOR/OFF/REV Selector Switchwith 2 Red Pilot Lightswith 2 Red/1 Green Pilot Lights

HJK

C400T15——

Two Red Pilot LightsOne Green Pilot LightTwo Red/One Green Pilot LightsOPEN/OFF/CLOSE Selector Switchwith 2 Red Pilot Lightswith 2 Red/1 Green Pilot Lights

PQRVWX

C400T10 �

—C400T16——

Rating Code Letter Rating Code Letter Rating Code Letter

120V 60 Hz208V 60 Hz

AE

240V 60 Hz380V 50 Hz

BL

480V 60 Hz600V 60 Hz

CD

Page 26: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-26

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlCombination Motor Controllers

Table 4-16. E22 Style Combination Motor Controller Cover Control

� To include any of the above cover controls, place the control code character in position 9 of your Catalog Number and add Mod Code P74. Example: ECX77H1ADA-P74. Full voltage non-reversing fusible starter with interchangeable heater OLR and START/STOP pushbutton with red RUN and green OFF pilot lights.

� Suffix for lights (required for field installed kits only) in the table below:

Note: All CMC design built in enclosure Size 5 do not contain a CPT. In order to supply internal power for cover control, the enclosure must increase to Size 6. If control power is to be supplied from a source outside of the enclosure, there is no need to oversize. Note that 32A and less FVNR designs permit room for a 24V DC power supply to be installed.

Description Factory Installed � Field Kits

Position 9CoverControlCode

CombinationOnly

CatalogNumber

Non-reversingSTART/STOP Pushbuttons (PB)START/STOP PB & Red RUN LightSTART/STOP PB, Red RUN, & Green STOPPED LightHAND/OFF/AUTO Selector Switch (SS)H-O-A SS & Red RUN Light

BCDHJ

CE400T01CE400T02 �

CE400T03 �

CE400T04CE400T05 �

H-O-A SS, Red RUN, & Green STOPPED LightRed RUN Pilot LightGreen Off Pilot LightRed RUN/Green OFF Pilot LightON/OFF Selector Switch (SS)

KPQRS

CE400T06 �

CE400T10 �

CE400T11 �

CE400T12 �

CE400T07

ON/OFF SS, Red RUN LightON/OFF SS, Red RUN, & Green STOPPED Light

TU

CE400T08 �

CE400T09 �

ReversingFWD/REV/STOP Pushbuttons (PB)FWD/REV/STOP PB + Red FWD & REV LightsFWD/REV/STOP PB, Red FWD/REV, & Green STOPPED

FOR/OFF/REV Selector Switch (SS)FOR/OFF/REV SS + Red FWD & REV Lights

BCD

HJ

CE400T50CE400T51 �

CE400T52 �

CE400T53CE400T54 �

FOR/OFF/REV SS, Red FWD/REV, & Green STOPPEDOPEN/OFF/CLOSE Selector Switch (SS)OPEN/OFF/CLOSE SS + Red FWD & REV LightsOPEN/OFF/CLOSE SS, Red FWD/REV, & Green STOPPED

KVWX

CE400T55 �

CE400T56CE400T57 �

CE400T58 �

Rating CatalogSuffix

Rating CatalogSuffix

120V 60 Hz208V 60 Hz240V 60 Hz

AEB

277V 60 Hz380V 50 Hz460V 60 Hz600V 60 Hz

HLCD

Page 27: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-27IEC Contactors & Starters

4

XT IEC Power ControlCombination Motor Controllers

Product SelectionTable 4-17. Class ECX76 — Combination Motor Controller (CMC) — Non-reversing Starter

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 4-24.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX76D4AAA-_. To order Type 4

Painted Steel, change that digit to 3.� Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions.

Table 4-17. Class ECX76 — Combination Motor Controller (CMC) — Non-reversing Starter (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 4-24. Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions.

Size Amps Maximum hp � Coil voltage @ 60 Hz �

Type 1/IP23General Purpose

Type 4X/IP66 ��

WatertightComponent �

Motor Voltage 1-phase 3-phase Catalog Number

CatalogNumber

CatalogNumber

D 12 115208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX76D1AAA-_ECX76D1EAA-_ECX76D1BAA-_ECX76D1LAA-_ECX76D1CAA-_ECX76D1DAA-_

ECX76D4AAA-_ECX76D4EAA-_ECX76D4BAA-_ECX76D4LAA-_ECX76D4CAA-_ECX76D4DAA-_

XTPR_ _ _BC1

H 32 115208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX76H1AAA-_ECX76H1EAA-_ECX76H1BAA-_ECX76H1LAA-_ECX76H1CAA-_ECX76H1DAA-_

ECX76H4AAA-_ECX76H4EAA-_ECX76H4BAA-_ECX76H4LAA-_ECX76H4CAA-_ECX76H4DAA-_

XTPR_ _ _BC1

Size Amps Maximum hp � Coil voltage @ 60 Hz �

Type 4X Nonmetallic/IP66 Watertight

Type 12/IP65Dust-Tight

Component

Motor Voltage 1-phase 3-phase Catalog Number

CatalogNumber

CatalogNumber

D 12 115208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX76D5AAA-_ECX76D5EAA-_ECX76D5BAA-_ECX76D5LAA-_ECX76D5CAA-_ECX76D5DAA-_

ECX76D8AAA-_ECX76D8EAA-_ECX76D8BAA-_ECX76D8LAA-_ECX76D8CAA-_ECX76D8DAA-_

XTPR_ _ _BC1

H 32 115208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX76H5AAA-_ECX76H5EAA-_ECX76H5BAA-_ECX76H5LAA-_ECX76H5CAA-_ECX76H5DAA-_

ECX76H8AAA-_ECX76H8EAA-_ECX76H8BAA-_ECX76H8LAA-_ECX76H8CAA-_ECX76H8DAA-_

XTPR_ _ _BC1

Cover Control . . . . . . . . . . . . . . . . . . . . Page 4-25Dimensions. . . . . . . . . . . . . . . . . . . . . . Page 15-5Modifications Codes . . . . . . . . . . . . . Page 16-40Technical Data, MMPs . . . . . . . . . . . CA08102001ETechnical Data, Contactors . . . . . . . Page 18-19

Page 28: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

4-28

For more information visit: www.eaton.com PG03300001E

IEC Contactors & Starters

4

XT IEC Power ControlCombination Motor Controllers

Table 4-18. Class ECX77 — Combination Motor Controller (CMC) — Non-reversing Starter with CPT

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 4-24.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX77D4AAA-_. To order Type 4

Painted Steel, change that digit to 3.� Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions.

Table 4-18. Class ECX77 — Combination Motor Controller (CMC) — Non-reversing Starter with CPT (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 4-24. Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions.

Size Amps Maximum hp � Coil voltage @ 60 Hz �

Type 1/IP23General Purpose

Type 4X/IP66 ��

WatertightComponent �

Motor Voltage 1-phase 3-phase Catalog Number

CatalogNumber

CatalogNumber

D 12 115208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX77D1AAA-_ECX77D1EAA-_ECX77D1BAA-_ECX77D1LAA-_ECX77D1CAA-_ECX77D1DAA-_

ECX77D4AAA-_ECX77D4EAA-_ECX77D4BAA-_ECX77D4LAA-_ECX77D4CAA-_ECX77D4DAA-_

XTPR_ _ _BC1

H 32 115208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX77H1AAA-_ECX77H1EAA-_ECX77H1BAA-_ECX77H1LAA-_ECX77H1CAA-_ECX77H1DAA-_

ECX77H4AAA-_ECX77H4EAA-_ECX77H4BAA-_ECX77H4LAA-_ECX77H4CAA-_ECX77H4DAA-_

XTPR_ _ _BC1

Size Amps Maximum hp � Coil voltage @ 60 Hz �

Type 4X Nonmetallic/IP66 Watertight

Type 12/IP65Dust-Tight

Component

Motor Voltage 1-phase 3-phase Catalog Number

CatalogNumber

CatalogNumber

D 12 115208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX77D5AAA-_ECX77D5EAA-_ECX77D5BAA-_ECX77D5LAA-_ECX77D5CAA-_ECX77D5DAA-_

ECX77D8AAA-_ECX77D8EAA-_ECX77D8BAA-_ECX77D8LAA-_ECX77D8CAA-_ECX77D8DAA-_

XTPR_ _ _BC1

H 32 115208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX77H5AAA-_ECX77H5EAA-_ECX77H5BAA-_ECX77H5LAA-_ECX77H5CAA-_ECX77H5DAA-_

ECX77H8AAA-_ECX77H8EAA-_ECX77H8BAA-_ECX77H8LAA-_ECX77H8CAA-_ECX77H8DAA-_

XTPR_ _ _BC1

Cover Control . . . . . . . . . . . . . . . . . . . . Page 4-25Dimensions . . . . . . . . . . . . . . . . . . . . . . Page 15-5Modifications Codes. . . . . . . . . . . . . . Page 16-40Technical Data, MMPs . . . . . . . . . . . CA08102001ETechnical Data, Contactors . . . . . . . Page 18-19

Page 29: New Contents IEC Contactors & Starters · 2017. 5. 31. · April 2008 PG03300001E For more information visit: IEC Contactors & Starters 4-3 4 XT IEC Power Control Contactors and Starters

April 2008

PG03300001E For more information visit: www.eaton.com

4-29IEC Contactors & Starters

4

XT IEC Power ControlCombination Motor Controllers

Table 4-19. Class ECX78 — Combination Motor Controller (CMC) — Reversing Starter

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request.� Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 4-24.� These are the Catalog Numbers for Type 4X 304-Grade Stainless Steel, as indicated by the seventh digit 4. Example: ECX78D4AAA-_. To order Type 4

Painted Steel, change that digit to 3.� Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions.

Table 4-19. Class ECX78 — Combination Motor Controller (CMC) — Reversing Starter (Continued)

� 1 hp = 0.746 kW.� Voltage is listed @ 60 Hz unless otherwise noted. Other voltages available upon request. Select proper “XTPR” MMP Overload Amperage range as per motor FLA, see Page 4-24. Handle mechanism is rated Type 1 or 12. Contact local sales office for availability of Type 4X versions.

Size Amps Maximum hp � Coil voltage @ 60 Hz �

Type 1/IP23General Purpose

Type 4X/IP66 ��

WatertightComponent �

Motor Voltage 1-phase 3-phase Catalog Number

CatalogNumber

CatalogNumber

D 12 115208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX78D1AAA-_ECX78D1EAA-_ECX78D1BAA-_ECX78D1LAA-_ECX78D1CAA-_ECX78D1DAA-_

ECX78D4AAA-_ECX78D4EAA-_ECX78D4BAA-_ECX78D4LAA-_ECX78D4CAA-_ECX78D4DAA-_

XTPR_ _ _BC1

H 32 115208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX78H1AAA-_ECX78H1EAA-_ECX78H1BAA-_ECX78H1LAA-_ECX78H1CAA-_ECX78H1DAA-_

ECX78H4AAA-_ECX78H4EAA-_ECX78H4BAA-_ECX78H4LAA-_ECX78H4CAA-_ECX78H4DAA-_

XTPR_ _ _BC1

Size Amps Maximum hp � Coil voltage @ 60 Hz �

Type 4X Nonmetallic/IP66 Watertight

Type 12/IP65Dust-Tight

Component

Motor Voltage 1-phase 3-phase Catalog Number

CatalogNumber

CatalogNumber

D 12 115208230380460575

1/21-1/22

———

—3357-1/2

10

120208240380/50 Hz480600

ECX78D5AAA-_ECX78D5EAA-_ECX78D5BAA-_ECX78D5LAA-_ECX78D5CAA-_ECX78D5DAA-_

ECX78D8AAA-_ECX78D8EAA-_ECX78D8BAA-_ECX78D8LAA-_ECX78D8CAA-_ECX78D8DAA-_

XTPR_ _ _BC1

H 32 115208230380460575

355

———

—1010152025

120208240380/50 Hz480600

ECX78H5AAA-_ECX78H5EAA-_ECX78H5BAA-_ECX78H5LAA-_ECX78H5CAA-_ECX78H5DAA-_

ECX78H8AAA-_ECX78H8EAA-_ECX78H8BAA-_ECX78H8LAA-_ECX78H8CAA-_ECX78H8DAA-_

XTPR_ _ _BC1