C:\Users\dcichy\Documents\Newport, TN.pdf1. THE WORK INCLUDES THE
FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES
NECESSARY FOR AND REASONABLY INCIDENTAL TO THE COMPLETION, IN PLACE
OF ALL WORK AS ILLUSTRATED AND DESCRIBED IN DRAWINGS AND OUTLINE
SPECIFICATIONS AS PREPARED BY TJX. ALL SUCH WORK IS TO BE DONE BY
THE GENERAL CONTRACTOR UNLESS OTHERWISE NOTED.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AT THE JOB SITE, AND SHALL NOTIFY TJX IN WRITING OF ANY OMISSIONS, DISCREPANCIES, AND/OR CONFLICTS PRIOR TO SUBMITTAL OF BID OR BE RESPONSIBLE FOR THE SAME.
3. ALL WORK IS TO CONFORM TO THE REQUIREMENTS OF THE LOCAL AND STATE CODES. COORDINATE WITH THE OUTLINE SPECIFICATIONS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL REQUIRED BUILDING PERMITS AND FOR INSURING THAT ALL WORK CONFORMS TO APPLICABLE BUILDING CODES.
5. WHERE COLOR AND DESIGN SELECTIONS ARE REQUIRED, THE CONTRACTOR SHALL SUBMIT SAMPLES TO TJX FOR APPROVAL AND SELECTION.
6. SHOP DRAWINGS SHALL BE SUBMITTED TO TJX FOR APPROVAL PRIOR TO FABRICATION OF ANY WORK SPECIFIED HEREIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND PROPER INSTALLATION OF SAID WORK.
7. UNLESS OTHERWISE NOTED, IN THE TJX OUTLINE SPECIFICATIONS, NO SUBSTITUTIONS.
8. THE GENERAL CONTRACTOR SHALL HAVE DIRECT CONTROL AND MANAGEMENT OF ALL CONSTRUCTION OPERATORS AND BE RESPONSIBLE FOR THE SATISFACTORY OVERALL PERFORMANCE OF ALL HIS SUPPLIERS AND SUBCONTRACTORS AS WELL AS ALL ASSIGNED CONTRACTORS.
9. THE GENERAL CONTRACTOR IS TO RECEIVE, HANDLE, (STORE IF NECESSARY) AND BE RESPONSIBLE FOR ALL MATERIALS PROVIDED BY OTHERS. ALL MATERIALS SHALL BE ACCOUNTED FOR UPON RECEIPT. ANY MISSING OR DAMAGED PARTS SHALL BE REPORTED TO TJX IMMEDIATELY.
10. ALL WORK IS TO BE NEW EXCEPT WHERE INDICATED AS EXISTING.
11. ALL WOOD TO BE FIRE RETARDANT. RATINGS TO MEET REQUIREMENTS OF LOCAL, STATE, AND FEDERAL CODES.
12. GENERAL CONTRACTOR TO TURN OVER THE PROJECT IN COMPLETE OPERATING CONDITION.
13. THE CONTRACTOR IS RESPONSIBLE FOR TURNING OVER THE PREMISES IN A CLEAN CONDITION READY FOR TJX TO BEGIN OPERATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, CLEANING ALL WINDOWS (INSIDE AND OUT), MIRRORS, AND REMOVAL OF DUST FROM SURFACES AND FINAL VACUUMING OF CARPETS.
14. THE REFLECTED CEILING PLAN SHALL DICTATE LOCATION OF ALL EQUIPMENT AND LIGHTING. TJX PROJECT MANAGER IS TO BE INFORMED OF ALL CONFLICTS AND PROPOSED RESOLUTIONS. TJX PROJECT MANAGER HAS THE RIGHT TO FINAL APPROVAL OF PROPOSALS.
15. FLOORING CONTRACTORS SHALL BE RESPONSIBLE FOR PROPER PREPARATION AND INSTALLATION OF NEW FLOORING FINISHES. PREPARATION INCLUDES ADEQUATE CURING TIME FOR THE MASTIC TO REACH PROPER TACKINESS TO SET NEW FLOORING FINISHES. REFER TO TJX SPECIFICATION MANUAL FOR REQUIREMENTS FOR PREPARATION & TESTING.
16. FOR PURPOSES OF CLARITY, REFERENCES TO "C" REFERS TO THE CRITERIA DRAWINGS.
TJX GENERAL NOTES
PROVIDE CATWALK, INSTALL BEHIND SIGN FIELD. PROVIDE 30" X 30" LOCKABLE ACCESS TO INSIDE OF CANOPY.
ADD 3/4" EXTERIOR GRADE PLYWOOD BEHIND ENTIRE FACADE FOR INSTALLATION OF TJX SIGNS. SEE SECTION 1A OF SPECIFICATIONS.
SIZE OF SIGN TO BE DETERMINED BY LOCAL SIGN CODES AND COORDINATED WITH TJX BUILDING SIGN SPECIALIST.
Marshalls - Landlord Build-to-Suit (Outline Specifications #180) Rehab-to-Suit (Outline Specifications #1180)
ITEMS SUPPLIED BY MARSHALLS AND INSTALLED BY G.C.
1. Floor Mounted Carriage Bumper 2. Wall Bumper 3. Cup Dispenser 4. Sanitary Napkin Dispenser 5. Sanitary Napkin Disposal 6. Toilet Paper Dispenser 7. Deodorant Holder 8. Soap Dispenser 9. Toilet Seat Cover Dispenser 10. Freestanding Restroom Trash Receptacle 11. Power Poles 12. Dressing Room Lighted Mirrors 13. LP Bench 14. Permanent Chrome Rail 15. Baby Changing Table
EXT EXTERIOR REINF REINFORCED
GARMENT HANGER
GYPSUM BOARD
MANUFACTURER
MISCELLANEOUS
NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE NATURAL FINISHED WOOD
OUTSIDE DIMENSION
ABOVE FINISHED FLOOR
ELECTRIC WATER COOLER
CR.PL.
CONT
ELECTRIC
CONTINUOUS
AL
CEILING HEIGHT CASH REGISTER
ABBREVIATIONS
REVISION NUMBER
FINISH NUMBER
DOOR NUMBER
ROOM NUMBER
ELEVATION MARK
COLUMN SIGN TO BE 8'-0" MINIMUM A.F.F.
Scale
Date
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C1 EL
03/11/21 KTL
TITLE SHEET
NEWPORT, TN
JR/DEM
DRAWING INDEX
C1 TITLE SHEET C2 CONSTRUCTION PLAN C3 WALL SECTIONS & MISC. DETAILS C4 INTERIOR ELEVATIONS C5 REFLECTED CEILING PLAN C6 POWER PLAN C7 P.O.S., REGISTER, & ELEC DTLS. C8 FIXTURE PLAN
MARSHALLS STOREFRONT FINISH SCHEDULE FINISH
NO. MATERIAL MANUFACTURER SPECIFICATION 137 EIFS DRYVIT #310 "CHINA WHITE" 138 PAINT BENJAMIN MOORE CLOUD WHITE #967. PAINT TO MATCH CHINA WHITE DRYVIT. (EGGSHELL) 305 PAINT BENJAMIN MOORE #2061-20 "CHAMPION COBALT" (EGGSHELL) 325 VINYL DGS RETAIL INC. MARSHALLS - 3M DARK BLUE 326 SPANDREL GLASS SOLAR SEAL
COMPANY 1" CLEAR/CLEAR WITH SPANDREL. 1/4" CLEAR WITH 6-0025 HARMONY BLUE (2). 1/2" AIR SPACER. 1/4" CLEAR
327 EIFS DRYVIT #449 "BUCKSKIN" (SANDBLAST) 328 PAINT BENJAMIN MOORE #965 "TEMPORAL SPIRIT". PAINT TO MATCH "BUCKSKIN" DRYVIT.
(EGGSHELL) 329 EIFS DRYVIT #112 "SANDLEWOOD BEIGE" (SANDBLAST) 330 EIFS DRYVIT #578 "MIDNIGHT BLUE" (SANDBLAST) 338 LAMINATED PANEL SUNBRELLA MARINE BLUE
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
Mantrap Equipment Cushman & Wakefield 128 N. 1st Street Colwich, KS 67030 316-600-0971 Siobhan Panias ([email protected])
General light Fixtures, Plugmold, Power Poles, Safety Switches, GE Lighting control panel
(8 Week Lead Time) NESCO 40 Hudson Road
Canton, MA 02021 800-244-6980 [email protected]
16 - ELECTRICAL
HVAC Controls (4 Week Lead Time) Novar / Honeywell Multisite 6060 Rockside Woods Blvd., Suite 400, Independence, OH. 44131
216-682-1600 800-348-1235 [email protected]
HVAC Equipment/ Roof Exhaust Fans, Circulator Fans... York/Johnson Controls 5005 York Drive... 405-419-6447... Saul Diaz: [email protected]...
15 - MECHANICAL
Vertical Lifts/Scissor Lifts (12 Week Lead Time) Conveyors ( 8 week lead time)
Deluxe Systems, Division of W.T. Hight Co.
42 Winter Steet, Pembroke, MA. 02359 508-588-4410 [email protected]
Elevators & Escalators (West Coast Only) Mitsubishi Electric & Electronics 5665 Plaza Drive Cypress, CA 90630 714-220-4700
Elevators & Escalators ThyssenKrupp Elevator 114 Town Park Drive, Suite 300 Kennesaw, GA 30144 800-824-9666
Elevators & Escalators (16 Week Lead Time) Otis Elevator Company 61 Fourth Avenue Needham, MA 02494
781-433-8600 781-433-7700
Elevators & Escalators (16 Week Lead Time) Kone 1 Kone Court Moline, IL 61265 800-334-9556
Elevators & Escalators (16 Week Lead Time) Schindler Elevator Corporation 20 Whippany Road Morristown, NJ 07960 800-225-3123
14-CONVEYING SYSTEMS Hand Dryers EXCEL (Xlerator) 888-994-4128 [email protected]
Bailers, Compactor Security Door, Compactor Chute, & Compactor Machine PTR Baler & Compactor Co. 2207 East Ontario Street
Philadelphia, PA 19134 215-537-2211 (Sales) 215-533-5100 (Parts)
Patricia Dougherty: [email protected] Parts: [email protected]
Dock Seals and Bumpers Frommelt Dock & Door 35R Holden Street Winchester, MA 01890 800-243-3302
11 - EQUIPMENT
Toilet Partitions ASI Global Partitions 2171 Liberty Hill Road Eastanolles, GA 30538 706-827-2700 Cathy Bennet: [email protected]
General: [email protected]
10 - SPECIALTIES
Combo Only HomeGoods Side Flooring Parterre Flooring System 500 Research Drive Wilmington, MA 01887
978-203-5400 ext. 401 978-203-5400 ext. 217
Order: Jeff Leger: [email protected] Sales: Chris Easler: [email protected]
Faux Brick (6 to 8 Week lead Time) Symmetry International 55 Industrial Circle Lincoln, RI 02865 401-5781201 Juli Lancia: [email protected]
Processing Transition Strip MAPEI Corp. 1144 East Newport Center Dr. Deerfield Beach, FL 33442 800-992-6273 [email protected]
Vinyl Floor Planking (4 Week Lead Time) Mannington / Amtico International, Inc. 6480 Roswell Road Atlanta, GA 30328 800-321-2519 ext. 6412 Joyce Holbert: [email protected]
General: [email protected]
Wallcovering (4 Week Lead Time) MDC Wall Covering 1200 Arthur Avenue Elk Grove, IL 60007 800-486-9800 [email protected]
[email protected]
Restroom Wall (89 Smoke Grey) & Floor Grout (#60 Dusty Grey) Laticrete One Laticrete Park North
Bethany, CT 06524 1-800-243-4788 x1219 [email protected]
Restroom Wall & Floor Tile Daltile 1300 East Plano Parkway Plano, TX 75074
TP: 877-556-5728 800-486-5724
Tim Phoenix: [email protected] General: [email protected]
Vestibule Mat The Matworks 11900 Old Baltimore Pike Beltsville, MD 20705
MC: 301-832-8703 General: 800-523-5179
Vinyl Composition Tile (VCT) Armstrong Flooring Inc. Commercial National Accounts 877-212-8511 [email protected]
Acoustical Ceiling System Armstrong World Industries 2500 Industrial Drive Lancaster, PA 17603 800-442-4212 [email protected]
09 - FINISHES
Coiling Overhead Service Door Metro Door, Inc. 821 Industrial Drive, Lewisburg, TN. 37091
833-969-3667 [email protected]
Gabe Cross - Ext 743 Amanda Prosser - Ext 774
Doors, Door Frames, and Door Hardware DH Pace National Accounts 1901 E 119th St Olathe, KS 66061 417-831-5585 x 5622 Paula Jamison: [email protected] Bid requests: [email protected]
Jimmy Guard Don-Jo Mfg., Inc. 70 Pratt Junction Road P.O. Box 929 Sterling, MA 01564 978-422-3377
Impact Doors Eliason Easy Swing Door Division 9229 Shaver Road Kalamazoo, MI 49003 800-543-4455 [email protected] - add TJX to subject
line
Sliding Door Operators (8 Week Lead Time) Stanley Automatic Doors 65 Scott Swamp Road... RD: 860-679-6431... Ryan Driscoll: [email protected]
08 - DOORS & GLASS
Combo Only HomeGoods Side Light Valance/Molding/Focal Wall Molding/Focal Wall
Kit/Restroom Mirror Molding (4 Week Lead Time) DGS Retail LLC 60 Maple Street
Mansfield, MA 02048 508-337-2990 [email protected]
Slatwall Column Corner Guard Wind Mill Woodwork, Inc. 200 Balsam Road Sheboygan Fall, WI 53085 800-548-7528 (Sales)
Corner Guards ATR Sales, Inc. 41 Talbot Road Northboro, MA 01532 (508) 393-8529
Outrigger ( 6 week lead time) Light Valance Brackets (4 week lead time) LOZIER Main: 800-228-9882,
Direct: 402-457-8218 Terry Marchand, Account Services
[email protected] [email protected]
Light Valance/ Molding & Focal Wall Molding... DGS Retail LLC 60 Maple Street... 508-337-2990 [email protected]
Slatwall System, Beadboard Paneling (6 Week Lead Time) DGS Retail 1201 Kirk Street
Elk Grove Village, IL 60007 (847) 350-3020 Erin Patterson [email protected]
06 - CARPENTRY
Description Company Name Address Contact Phone Contact Email
**LONG LEAD TIME POSSIBLE** NOTE: WHEN CONTACTING VENDORS, PLEASE INDICATE THAT YOU ARE WORKING ON A TJX PROJECT TO ENSURE NATIONAL ACCOUNT PRICING/SUPPLY.
APPROVED MARSHALLS VENDOR LIST
32' - 4" FIX. STOR. SYS.
PALLET STAGING
END
FOCAL WALL SAVING NEVER LOOKED SO GOOD
FO CA
L W
AL L
LO VE
T HE
L AB
EL A
ND T
HE P
RI CE
FO CA
L W
AL L
BR AN
D NA
M ES
F OR
L ES
E. W
8' -
106
108
STORE FIXTURES BY OTHERS
THREE (3) 2 1/2" CONDUITS TO BE CONCEALED IN FLOOR & WALL ON SALES AREA SIDE.
CONDUIT TERMINATION POINT. LOCATED UNDER CASH REGISTER COUNTER.
ALL V.C.T. TO BE INSTALLED WITH 1/4 TURN PATTERN
A MINIMUM OF (2) TWO STOREFRONT WINDOWS SHALL HAVE A MINIMUM CLEAR LITE DIMENSION OF 4'-0" WIDE X 6'-0" HIGH
ALL GLASS INCLUDING GLASS DOORS TO BE PROTECTED BY A HORIZONTAL MULLION ON BOTH SIDES @2'-4" A.F.F.
SEE NOTE ON INTERIOR ELEVATIONS SHT. FOR GLAZING REQUIREMENTS @ VESTIBULE.
UPPER GLAZING @ DOOR TRANSOMS ON SALES SIDE SHALL RETAIN A 1" GAP BETWEEN GLAZING AND VERTICAL FRAMES TO ELIMINATE NEGATIVE AIR PRESSURE IN VESTIBULE. GLASS TO BE RADIUSED AND GROUND SMOOTH ON BOTH SIDES.
ALL TOILET FIXTURES, HARDWARE, ACCESSORIES, MIRRORS, AND FINISHES TO BE SUPPLIED BY G.C. AS PER TENANT SPECS. TOILET PAPER HOLDERS AND ALL DISPENSERS ARE SUPPLIED BY TENANT AND ISTALLED BY G.C. G.C. IS RESPONSIBLE TO PROVIDE ALL BLOCKING FOR TOILET ROOM ACCESSORY INSTALLATION. PLEASE COORDINATE WITH SHEET C4 OF THE CRITERIA PLANS AND THE TJX PROJECT MANAGER FOR EXACT LOCATIONS.
NOTE FOR COMPACTOR: IF EXTERIOR GRADE IS MORE THAN 12 INCHES BELOW THE INTERIOR FINISHED FLOOR, THE BOTTOM OF THE SECURITY DOOR SHOULD BE AT 44" A.F.F. IF LESS THAN 12 INCHES BELOW, THE SECURITY DOOR SHOULD BE AT 54" A.F.F. COMPACTOR IS 50" HIGH.
8' X8
' C O
IL IN
G S
ER VI
C E
D O
O R
EA C
H J
AM B
INSTALL 3 1/2" SOUND INSULATION IN ALL PARTITIONS & CLG. IN MGR. OFFICE
SE E
D ET
AI L
7/ C
4 FO
ES .
LIGHTS TO BE MOUNTED AT 12'-0" A.F.F. MECHANICAL, ELECTRICAL, AND PLUMBING TO BE MOUNTED WITH ADEQUATE CLEARANCE BETWEEN TOP OF LIGHTING FIXTURES AND ROOF DECK.
10' X 40' COMPACTOR PAD
VESTIBULE 1
PROCESSING ROOM
G.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING V.C.B. ON ALL CHECKOUTS, LAYAWAY PICK-UP COUNTER, LOUNGE KITCHENETTE, AND INSIDE/OUTSIDE JEWELRY COUNTER (IF APPLICABLE).
NOTE: DIRECTION OF ARROWHEADS INDICATES DIRECTION OF FLOORING
FOR RELEASE LATCHES MINIMUM CLEARANCE REQ.
19" CLEAR FROM ANY OBSTRUCTIONS 34" AFF TO OPERATION POINT
TYP. COL. COVER UNLESS NOTED OTHERWISE AT SALES FLOOR
FLOOR DRAIN
VW C
T ER
M IN
AT IO
N P
O IN
BENJAMIN MOORE INSL-X TP2220 LATEX TRAFIC PAINT, COLOR-BLACK.
W H
ER E
R EQ
U IR
ED B
Y LO
C AL
C O
D E,
M ET
R O
D O
O R
28' - 10" 24' - 1" 23' - 11" 24' - 1" 28' - 10"
15 4'
8' - 6" 20' - 9" 5' - 0" 16' - 5" 10' - 0"
17 ' -
3 "
6' -
5' - 11 1/2"
/2 "
19' - 11" 3' - 10" 15' - 7 1/2" 25' - 2 1/2" 17' - 1 1/2" 15' - 7 1/2" 3' - 1 1/2"4' - 5 1/2" 10' - 10"
WOMEN'S D.R.
4' - 0"
4' - 0"
1" 3'
3' - 1 1/2"
HOLD 22' - 9"
HOLD 7' - 0"
HOLD 56' - 0"
H O
LD 26
1 C3
4 C3
4 C3
4 C3
4 C3
LOGO
* OPENING SIZE IS THE ACTUAL SIZE OF THE DOOR UNLESS OTHERWISE NOTED. *INTERIOR DOORS ARE TO MEET ADA REQUIREMENTS AND MUST HAVE 18” CLEAR ON THE PULL/STRIKE SIDE OF THE DOORS.
REFER TO FIXTURE INSTALLATION MANUAL FOR 'ADA' EXIT SIGNS AS NOTED ON DOOR & HARDWARE SCHEDULE.
10 ' -
0 "
KICK PLATE AS REQUIRED
HOLLOW METAL HOLLOW METAL ALUMINUM ALLOY RECEIVING ROLL-UP DOOR (SEE DOOR
SCHEDULE FOR SIZING).
HEAD AND JAMB
WIRE MESH (SEE DTL.)
FOR FURTHER DETAIL ON WALL SYSTEM INSTALLATION, REFER TO THE MANUFACTURER INSTALLATION INSTRUCTIONS.
CORNER BEAD (TYP.) METAL KNOCK DOWN FRAME (TYP.)
METAL KNOCK DOWN FRAME
2 '-
0 "
X C3
X C3
NOTE:
1. INSTALL 3" WIDE EPOXY THRESHOLD UTILIZING "MAPEI - PLANIBOND EBA" WHICH IS A TWO COMPONENT BONDING AGENT AND PRIMER. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED INSTALLATION METHODS. SYSTEM FORMALLY KNOW AS "EPO / BOND30".
2. CENTER REDUCER STRIP TO DOOR FRAME OR WHERE INDICATED ON PLAN.
CONCRETE SLAB SALES FLOOR FINISH.
REFER TO C-1
SINGLE DRAWER
BASE UNITS
ADJUSTABLE SHELF
59" A.F.F.
15" DEEP SHELF WITH 2" RADIUS EXPOSED CORNERS.
CABINETS: AS MANUFACTURED BY "HAMPTON BAY (OR EQUAL) 30" W × 27" H X 22" D CLEAR KNEE SPACE AT SINK (3) 18" W × 24" D. BASE CABINETS WITH ADJUSTABLE SHELVES - CUT TOE SPACE AS REQUIRED FOR 34" ADA HEIGHT TOP OF SINK RIM. (1) 18" H × 36" W × 12" D. WALL CAB. (2) HAMPTON BAY DISH WASHER END PANEL.
COLOR: MANUFACTURER'S SATIN WHITE FINISH
FURNISH MANUFACTURER'S STANDARD 4" DRAW AND DOOR PULLS
COORDINATE LOCATION OF PAPER TOWEL AND SOAP DISPENSERS WITH TJX PM.
ELECTRICAL REQUIREMENTS AS SHOWN
ONE "ADA" COMPLIANT DROP IN STAINLESS STEEL SINK, AND "ADA" COMPLIANT FAUCET. PAINT SINK CUT OUT EDGES WITH OIL BASED PAINT.
AMERICAN WITH DISABILITIES ACT (ADA) REQUIREMENTS: CONTRACTOR SHALL ORDER "HANDICAP CABINETS" COMPLYING WITH ADA REQUIREMENTS AS FOLLOWS: 34" IS MAX. HEIGHT PERMITTED TO TOP OF SINK RIM OR COUNTER. PROVIDE SINK THAT DOES NOT EXCEED MAXIMUM DEPTH OF 6 1/2".
PROVIDE SLANTED FRONT PANEL AT SINK TO CONCEAL PLUMBING. COLOR TO MATCH CABINETS.
36"
5
4 "
HAMTON BAY. 30" × 4" FLAT FRONT PANEL ATTACHED AS REQUIRED
1A C4
1A C4
1
8 "
CUSTOM OPEN BOX CABINET 36"W × 24"H × 12"D. COLOR TO MATCH CABINETS.
2
5 "
4 "
HAMPTON BAY DISH WASHER END PANELHAMPTON BAY DISH WASHER END PANEL.
MODIFY AS REQUIRED.
6" VINYL COVE BASE
GALVANIZED ALUMINUM SILL COVER W/ 2" DOWNTURN LEG COLOR TO
MATCH WINDOW FRAME
NEW WALL EXTEND WALL CONSTRUCTION, INCLUDING PLYWOOD WHERE APPLICABLE TO UNDERSIDE OF DECK (BOTH SIDES). SEE CONSTRUCTION PLAN FOR WALL TYPE.
LEGEND
HARDWARE TO BE FINISHED AS FOLLOWS: 1.PROVIDE BURGLAR PROOF HINGES N.R.P. WHERE EXPOSED TO OUTSIDE OR COMMON AREAS. 2. PROVIDE DOOR STOP ON ALL DOORS (INCLUDING SAFE DOOR), WHERE THEY ARE LIABLE TO DAMAGE THE WALL OR ADJACENT FIXTURE. 3.PAINT ALL METAL DOORS. REFER TO INTERIOR ELEVATIONS SHEET. 4.ALUMINUM ALLOY DOUBLE ACTION DOOR (ONE OR TWO DOORS) TO BE "EASY SWING" TYPE. 5.ALL LOCKS AND LOCKING DEVICES ARE TO BE BEST CONSTRUCTION CORES 6.G.C. TO INSTALL PERMANENT CORES SUPPLIED BY TENANT. 7.PROVIDE KAWNEER STYLE F-2 PUSH-PULL ON ALUMINUM AND GLASS DOORS. DO NOT INSTALL PULL ON DOORS NO. 3 (VEST. SIDE) 8.DOOR HOLDERS TO BE INSTALLED ON THE KICK-PLATE SIDE OF DOOR, EXCEPT AT TOILET ROOMS. 9.FOR EXTERIOR DOORS, PULL TO BE INSTALLED ON INSIDE OF DOOR, ABOVE DETEX. 10. THRESHOLD FOR VESTIBULE ENTRANCE AND EXIT DOORS BY ZERO INTERNATIONAL #1675A, ALUMINUM UTILITY SADDLE, 4"x1/2". 11. THRESHOLDS FOR EXTERIOR HOLLOW METAL DOORS BY ZERO INTERNATIONAL #654A, ALUMINUM UTILITY SADDLE, 4"x1/2"
Scale
Date
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C2 EL
03/11/21 KTL
CONSTRUCTION PLAN
NEWPORT, TN
JR/DEM
NO. ROOM
AC O
U ST
IC AL
T IL
ET ile
G YP
SU M
B O
AR D
N O
F IN
IS H
ED C
EI LI
N G
C EI
LI N
G H
EI G
H T
1 VESTIBULE 115 10' - 2" SECURE WITH HURRICANE CLIPS. PAINT ALL EXPOSED WALLS (305)
2 SALES Varies 341 Varies Varies SEE CONSTRUCTION PLAN AND INTERIOR ELEVATIONS FOR FINISHES.
3 PROCESSING ROOM 112 341 SEAL YELLOW SAFETY WALKWAY
4 DRESSING ROOM ENTRANCE 311 341 Varies 9' - 0" SEE SHEET C4 FOR FINISHES. 5 MEN'S DRESSING ROOM 312 341 334 9' - 0" SEE SHEET C4 FOR FINISHES. 6 WOMEN'S ADA DRESSING
ROOM 311 341 335 9' - 0"
7 MEN'S ADA DRESSING ROOM 312 341 334 9' - 0" 8 WOMEN'S DRESSING ROOM 311 341 335 9' - 0" SEE SHEET C4 FOR FINISHES. 9 CASH OFFICE 308 341 303 9' - 0" 10 HALL AT CASH 308 341 303 9' - 0" 11 L.P. OFFICE 308 341 303 9' - 0" 12 SYSTEMS ROOM 112 341 13 LOUNGE 106 /
108 342 116 /
DESIGNATION. FINISH NO. 407 MOUNTED @ 24" A.F.F.
14 JANITOR'S CLOSET 308 341 303 / 323
9' - 0"
308 341 303 9' - 0"
16 MANAGER'S OFFICE 308 341 303 9' - 0" 17 HALL AT LOUNGE 308 341 303 9' - 0" 18 MEN'S TOILET 340 341 303 /
339 9' - 0" PAINT CEILING #113. TILE ON
ALL WALLS TO 39 7/8" A.F.F. 19 WOMEN'S TOILET 340 341 303 /
339 9' - 0" PAINT CEILING #113. TILE ON
ALL WALLS TO 39 7/8" A.F.F. 20 LEARNING CENTER 308 341 303 9' - 0" SEE FIXTURE INSTALLATION
MANUAL FOR GRAPHICS PLACEMENT
NOT TO SCALEC2 6
DOOR & HARDWARE SCHEDULE DOOR LOCATION NO.
OPENING / DOOR SIZE HEAD & JAMB TYPE TYPE KICKPLATE HARDWARE REMARKSWIDTH HEIGHT
VESTIBULE 1 14' - 0" 7' - 8" --- --- --- HJ BIPARTING DURAGLIDE 3000. THRESHOLD & MOTOR HEADER INCLUDED, EXTERIOR & INTERIOR TRANSOM SUPPLIED AND INSTALLED BY GC. (SELF SUPPORTING TRANSOM REQUIRED).
VESTIBULE 2 14' - 0" 7' - 8" --- --- --- HJ BIPARTING DURAGLIDE 3000. THRESHOLD & MOTOR HEADER INCLUDED, EXTERIOR & INTERIOR TRANSOM SUPPLIED AND INSTALLED BY GC. (SELF SUPPORTING TRANSOM REQUIRED).
LOADING DOOR 3 8' - 0" 10' - 0" --- 4 --- OO SEE SPECS AT PLAN LOCATION THIS SHEET. (2) LOCKS PER DOOR.
PROCESSING ROOM 4 6' - 0" 7' - 0" C 3 1 SIDE --- FLAT FRAME BY GC, ELIASON EASY SWING DOORS (72"X84") #SCP-1 "ALUMINUM", BUMPERS EACH SIDE, EXIT SIGN, TYPE "B".
HALL AT LOUNGE 5 4' - 0" 7' - 0" A --- --- --- DRESSING ROOM ENTRANCE 6 18' - 0" 8' - 6" A --- --- --- USE CLEAR PLASTIC CORNER GUARDS. WOMEN'S ADA DRESSING ROOM 7 3' - 0" 7' - 0" B 2 1 SIDE AGW1V2 MOUNT DOOR STOP AS REQ'D. SO DOOR DOES NOT
HIT MIRROR. DOOR TO HAVE 1" UNDERCUT.
MEN'S ADA DRESSING ROOM 8 3' - 0" 7' - 0" B 2 1 SIDE AGW1V2 MOUNT DOOR STOP AS REQ'D. SO DOOR DOES NOT HIT MIRROR. DOOR TO HAVE 1" UNDERCUT.
PROCESSING ROOM COMPACTOR SECURITY DOOR
9 4' - 0" 4' - 0" --- --- --- O SLIDER COMPACTOR SECURITY DOOR. GC PURCHASE FROM PTR, GC INSTALLS, SEE PLAN FOR DOOR TYPE.
L.P. OFFICE 10 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV HALL AT CASH 11 3' - 0" 7' - 0" B 2 --- ACGL ELECTRIC STRIKE BY SDC. DOOR FRAME TO COME
READY FOR SDC 45 4S U, 4" FACE PLATE. SEE DETAIL ON DRAWING C7. DOOR TO HAVE 1" UNDERCUT.
CASH OFFICE 12 3' - 0" 7' - 0" B 1 1 SIDE ACGLSZ ELECTRIC STRIKE BY SDC. DOOR FRAME TO COME READY FOR SDC 45 4S U, 4" FACE PLATE. SEE DETAIL
ON DRAWING C7 SYSTEMS ROOM 13 3' - 0" 7' - 0" B 2 --- A1CWV USE TAMPER-PROOF HINGES. JANITOR'S CLOSET 14 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV LEARNING CENTER 15 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV EMERGENCY EXIT 16 3' - 0" 7' - 0" B 1 1 SIDE AGPRTY EXIT SIGN TYPE "B" EMERGENCY EXIT 17 3' - 0" 7' - 0" B 1 1 SIDE AGPRTY EXIT SIGN TYPE "B" EXIT MAN DOOR 18 3' - 0" 7' - 0" B 1 --- A1GPRSTY EXIT SIGN TYPE "B" MEN'S TOILET 19 3' - 0" 7' - 0" B 2 1 SIDE ACEFGV DOOR TO HAVE 1" UNDERCUT. WOMEN'S TOILET 20 3' - 0" 7' - 0" B 2 1 SIDE ACEFGV DOOR TO HAVE 1" UNDERCUT. ASSISTANT MANAGER'S OFFICE 21 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV LOUNGE 22 3' - 0" 7' - 0" B 2 1 SIDE ACGUV MOUNT DOOR HOLDER AS REQ'D. SO AS NOT TO BE A
TRIPPING HAZARD. MANAGER'S OFFICE 23 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV
HVAC AREA ANALYSIS
Dressing Room 1,056.3 SF Processing Room 1,269.3 SF Sales 15,045.1 SF Support 1,566.3 SF Systems Room 117.9 SF
DOOR HARDWARE NO HARDWARE DESCRIPTION HARDWARE MANUFACTURER & MODEL A HINGES STANLEY FBB179, 4½" × 4½" (1½ PAIR), US26D A1 HINGES STANLEY FBB191, 4½" × 4½" NRP (1½" PAIR), US32D B DOUBLE ACTING HINGE BOMMER #3029, 6 × 4½" 652 (1½" PAIR), US26D C CLOSER LCN "SMOOTHEE" #4031 X WMS AL (ON HINGE SIDE) D OPEN E PUSH PLATE ROCKWOOD 70C, 4" × 16" PUSH PLATE, US32D F PULL PLATE ROCKWOOD 110 × 70C, PULL PLATE 4" × 16", US32D G KICK PLATE ROCKWOOD K1050, 8" × DOOR WIDTH (MINUS 2"), US32D H MORTISE CYLINDER BEST #1E-7-6-C181-RP1 X L/C, 626 H1 RIM CYLINDER BEST #12E-7-2-S2-RP X L/C, 626 J TURNKNOB BEST #1EA-6-A4-C413-RP2, 626 K DUMMY CYLINDER BEST # 1E-04, 626 L STOREROOM LEVER LOCKSET BEST #9K3-7-D-15-D-S3 X L/C, 626 L1 CLASSROOM LEVER LATCHSET BEST #9K3-7-R-15-D-S3 X L/C, 626 M PASSAGE LEVER LATCHSET BEST #9K3-O-N-15-D-S3, 626 N CLASSROOM TUBULAR DEAD
LOCK BEST #8T3-7-S-8TD3B-STK, 626 (FOR EXTERIOR DOOR W/CUT OUT)
O PADLOCK BEST #21-B-7-22-L X L/C, 626 P ALARM EXIT LOCK-SGL DETEX ECL-230D-PH ECL-1595, GRAY P1 ALARM EXIT LOCK UL-SGL DETEX ECL-600, GRAY (USE WITH FIRE RATED DOORS) P2 ALARM EXIT LOCK UL-SGL-O\A DETEX LEVER TRIM ECL-620, GRAY Q ALARM EXIT LOCK-DBL DOORS DETEX ECL-230D-PH ECL-1595 VRA-143B 84, GRAY R CHAIN CRASH STOP IVES #CS115 × 25½, US26D
NATIONAL GUARD MODEL: 16A (DRIP CAP) S DOOR SAFETY VIEWER ROCKWOOD #622 CRM 190 DEGREE T WEATHERSTRIPPING (INCLUDES) NATIONAL GUARD C627A (BRUSH SEAL),
NATIONAL GUARD MODEL 16A (DRIP CAP), NATIONAL GUARD 122NA (HEAD & JAMB GASKETING), NATIONAL GUARD 424E (THRESHOLD)
U PUSH BUTTON LOCKSET ALARM LOCK SL2700IC-26D, TRILOGY T2 (KEY OVERRIDE) V FLOOR STOP & DOOR HOLDER ROCKWOOD #491, US26D V1 PLUNGER DOOR HOLDER ROCKWOOD #459, US26D V2 FLOOR MOUNTED DOOR STOP ROCKWOOD #441CU, US26D V3 WALL MOUNTED DOOR STOP ROCKWOOD - DH PACE TO SELECT W STOREROOM LEVER LOCKSET
(TACTILE) BEST #9K3-7-D-15-D-S3 X L/C TL (B), 626
W1 PRIVACY LEVER SET BEST #7KC3-0-L-15-D-S3, 626 X FLUSH BOLT ROCKWOOD 55 US26D Y PULL ROCKWOOD 131, US26D Z JIMMY GUARD DON-JO MFG, INC. #ILP-206-SL
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
TOP OF BOX WALL 7'-11" A.F.F. (FINISH WITH 5/8" GYP. BD.
TOP) PAINT #303.
22" MIN. FROM FACE OF SLATWALL (TYP.) V.I.F.
GYPSUM BOARD BOX CORNER W/ 5/8" GYP. BD.
ON METAL STUDS.
303
341341
5/8" GYPSUM BOARD.
E.T.M.
2
1 MIRROR 4 SIDES OF COLUMN FROM 2' - 4½" (TOP OF BUMPER) TO 8' - 0". UNLESS NOTED OTHERWISESIZE VARIES W/ COLUMN SIZE. (12" MINIMUM WIDTH, TYP. )
ELECTRICAL OUTLET @
18" A.F.F.
6 ½
NOTES:
1. REFER TO SIZE TABLE TO DETERMINE DIMENSIONS. WIDTH AND DEPTH ARE INSIDE DIMENSIONS OF THE CAGE STRUCTURE.
2. CONSTRUCT USING 2" x 4" WOOD STUDS COVERED ALL SIDES EXCEPT WHERE AGAINST WALL WITH 14 GAUGE, 1" X 2" WIRE MESH. SECURE TO WALL. PROVIDE 1/2" PLYWOOD TOP. PROVIDE FIELD BUILT DOORS FULL HEIGHT AND ALLOWING ACCESS TO FULL WIDTH OF SHELVES. CONSTRUCT DOORS OF 2" x 4" STUDS AND HARDWARE CLOTH WITH CROSS BRACING, HINGES, AND LOCK HASPS. SHELVES BY OTHERS.
3. HEIGHT OF LOCKING STORAGE CAGE SHALL BE DETERMINED BY SIZE TABLE.
4. GENERAL CONTRACTOR SHALL INCLUDE SECURITY CAGE IN BASE BID.
LOCK HASPS
TOP OF SHELVING UNIT
8'
DEPTH WIDTH HEIGHT
SECURITY CAGE (10')
CAGE TYPE
O VE
R AL
L H
EI G
H T
SE E
SI ZE
T AB
DIGI UNIT
DIGI UNIT
MULLION
GLASS
GLASS
2'
- 4
CORE FLOOR & SET SLEEVES AS PER INSTALLATION INSTRUCTIONS
LENGTH: USE LONGEST STANDARD LENGTHS POSSIBLE TO FIT PLAN. PROVIDE CUSTOM LENGTH SECTIONS WHERE REQUIRED.
6 "
FLOORING SPEC
ARMSTRONG SAFTEY ZONE SLIP RETARDENT
#57004 SLATE BLACK
FIN. FL. FIN. FL.
DIRECT RING DOWN CONNECTOR
WALL MOUNTED OR CEILING HUNG LOCATION SIGN. (SEE SIGN PACKAGE BY TJX)
FIN. FLOOR
5/8" PLYWOOD 1" INSUL.
VERTICAL CONTROL JOINT (USG CONTROL JOINT #093) 32'-0" O.C. SEE SPECIFICATION BOOK
NOTES:
FURNISH AND INSTALL HORIZONTAL STUDS TO RECEIVE PERIMETER CEILING ANGLE.
FURNISH AND INSTALL CONTINUOUS SHOE AND PLATE W/ HORZ. BLOCKING AT MID POINT OF STUD HEIGHT.
FOR WALLS HIGHER THAN FINISHED CEILING, BRACE TO UNDERSIDE OF STRUCTURE FOR WALL SUPPORT.
4'-0" X 8'-0" SHEETS OF PLYWOOD TO BE MOUNTED HORIZONTALLY. STAGGER ALL JOINTS AND EXTEND 6" ABOVE FINISHED CEILING.
FOR AREAS WITHOUT A CEILING, INSTALL 5/8" PLYWOOD TO 12'-0" A.F.F.
FOR CASH OFFICE, DEMISING AND APPLICABLE DRESSING ROOM WALLS 5/8" PLYWOOD TO EXTEND TO UNDERSIDE OF ROOF DECK.
INSULATION TO UNDERSIDE OF DECK AT ALL EXPOSED EXTERIOR DEMISING WALLS.
FOR WALLS FINISHED WITH OUTRIGGER OR SLATWALL SYSTEM REFER TO SECTION DETAIL (00/C3 OR 01/C3).
1
2
3
4
5
6
1 1/2" x 3 1/2" x 12'-0" WOOD STUD. INSTALL
ON FLAT SIDE WITH LAG OR TOGGLE
BOLTS @ 24" O.C. INSTALL BOTTOM OF STUD VERTICALLY 30" A.F.F.
MASONRY WALL
B C3
1 5/8" METAL FURRING CHANNELS, MOUNTED VERTICALLY
MASONRY WALL
1 5/8" METAL FURRING CHANNELS, MOUNTED VERTICALLY
MASONRY WALL
45/8" PLYWOOD
5 BATT. INSULATION TO UNDERSIDE OF DECK
6
45/8" PLYWOOD
1 3
D C3
MASONRY WALL
6
45/8" PLYWOOD
1 3
G1 C3
6" 20 GA METAL STUDS @ 16" O.C.
5/8" PLYWOOD CONTINUOUS FULL HEIGHT TO UNDERSIDE OF DECK
4
EXTERIOR WALL FINISH
6" 20 GA METAL STUDS @ 16" O.C.
5/8" PLYWOOD CONTINUOUS FULL HEIGHT TO UNDERSIDE OF DECK 4
INSTALL 3 1/2" THICK FIBERGLASS NOISE BARRIER BATTS TO UNDERSIDE OF DECK
5
1 3
6
T C3
1 3
6
U C3
1' -
6"
10 "
45/8" PLYWOOD TO 12'-0" AFF
3
6" 20 GA METAL STUDS @ 16" O.C.
14 GAUGE. 1" X 2" WIRE MESH INSTALLED ABOVE 12'-0" ON
STOCKROOM SIDE TO UNDERSIDE OF DECK. W2
C3
45/8" PLYWOOD TO 12'-0" AFF
3
6" 20 GA METAL STUDS @ 16" O.C.
14 GAUGE. 1" X 2" WIRE MESH INSTALLED ABOVE 12'-0" ON
STOCKROOM SIDE TO UNDERSIDE OF DECK.
WALL SYSTEM
3'
-6 "
5/8" GYP. BD. ALL
303
314
314
218
341
303
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
12 ' -
303
314
314
218
341
303
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
6
6 ½
REFER TO SLATWALL INSTALLATION INSTRUCTIONS FOR ORIENTATION OF SLATWALL PANELS AT COLUMNS
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
BOTTOM OF ROOF DECK
PAINT STRUCTURE ABOVE #303.
ADD FINISHED CORNER BEAD
6
REFER TO SLATWALL INSTALLATION INSTRUCTIONS FOR ORIENTATION OF SLATWALL PANELS AT COLUMNS
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
DETAIL #1
1/4" MIRROR
SECTION B-B
OUTLET
E.T.M. CLEAR ANODIZED ALUMINUM CORNER GUARDS BY STYLMARK, MODEL #120058 CORNER COLUMN MOULDING, COLOR TO BE #020 SATIN NATURAL, NO SUBSTITUTIONS.
1/4" MIRROR TO BE INSTALLED ON ALL SIDES OF SALES AREA COLUMNS FROM 2'-4½" (TOP OF BUMPER) TO 8'-0". THE G.C. IS TO INSTALL A PLASTIC LAMINATE/PLYWOOD PANEL ON COLUMNS HAVING A SENSOR, EXTINGUISHER, OR TELEPHONE MOUNTED ON THE REAR SALES AREA SIDE. SEPARATION BETWEEN MIRROR & LAM. PANEL TO BE "STYLMARK" MIRROR DIVIDER TRIM # 420109. (SEE ELEVATION THIS SHEET)
THERMOSTAT SERVICE
TELEPHONE SERVICE
STRUCTURAL COLUMN.
DETAIL #2
1/4" MIRROR
LAMINATE ON 1/4" PLYWOOD
BLOCKING BEYOND (5/8" PLYWOOD)
3/8" WOOD BLOCKING @ COLUMNS ONLY
PAINTED 5/8" GYPSUM WALLBOARD.
NOTES:
1. PLYWOOD & LAMINATE PANELS TO BE INSTALLED ON THE BACK SIDE OF A COLUMN HAVING A TELEPHONE, FIRE EXTINGUISHER, OR SENSORS MOUNTED AT 54" A.F.F. ALL SIDES REQUIRE MIRRORS EXCEPT AT PLASTIC LAMINATE PANEL. REFER TO INTERIOR ELEVATION SHEET FOR FINISH OF PLASTIC LAMINATE PANEL. SEE ELEVATION, THIS SHEET.
2. MIRRORS SHALL BE LIBBY-OWENS-FORD MIRROR OR APPROVED EQUAL.
3. ALL SQUARE COLUMNS SHALL BE MIRRORED ON ALL FOUR SIDES FROM 2'-4½" (TOP OF BUMPER) TO 8'-0". (EXCEPT AT PLASTIC LAMINATE PANEL FOR PHONE, T-STATS)
4. ELECTRICAL OUTLETS ON COLUMNS IN SALES AREA TO BE 18" A.F.F. (CENTERED ON COLUMN) UNLESS OTHERWISE NOTED. LOCATE ON THE BACK SIDE OF COLUMN AWAY FROM THE AISLE. PLEASE REFER TO C6 (POWER PLAN) FOR SITE SPECIFIC LOCATIONS.
5. PROVIDE HORIZONTAL 2" X 4" WOOD BLOCKING BEHIND BUMPER MOLDINGS AT 6½" A.F.F. AND AT 24" A.F.F. SECURE BUMPER MOLDINGS TO WOOD BLOCKING IN WALL.
6. T-STAT, TELEPHONE AND FIRE EXTINGUISHER ARE ALWAYS TO BE MOUNTED ON THE SAME SIDE OF THE COLUMN MOUNTED ON PLASTIC LAMINATE PANEL. UNLESS OTHERWISE NOTED, LOCATE ON THE BACK SIDE OF COLUMN AWAY FROM THE AISLE. PLEASE REFER TO C6 (POWER PLAN) FOR SITE SPECIFIC LOCATIONS. COORDINATE FINAL LOCATIONS WITH TJX VENDORS
SECTION A-A
POINTS OF COLUMN.
E.T.M.
2
1 MIRROR 4 SIDES OF COLUMN FROM 2' - 0" (TOP OF BUMPER) TO 8' - 0". UNLESS NOTED OTHERWISESIZE VARIES W/ COLUMN SIZE. (12" MINIMUM WIDTH, TYP. )
ELECTRICAL OUTLET @
18" A.F.F.
6
X C3
1 1/2" x 3 1/2" WOOD STUD @16" O.C. OPEN TO CONSTRUCTION TO UNDERSIDE OF DECK
2
14 GAUGE 1" x 2" WIRE MESH. INSTALL ON STOCK ROOM SIDE.
CONFIRM ALL OUTRIGGER DIMENSIONS WITH THE INSTALLATION INSTRUCTIONS.
6" VINYL BASE
5/8" GYP. BOARD
5/8" GYP. BOARD
5/8" GYP. BOARD
SALES FLOOR TILE MUST BE COMPLETE PRIOR TO OUTRIGGER INSTALLATION.
SE E
C 5
SH EE
T FO
R C
EI LI
N G
H EI
G H
6" VINYL BASE
5/8" GYP. BOARD
5/8" GYP. BOARD
5/8" GYP. BOARD
SALES FLOOR TILE MUST BE COMPLETE PRIOR TO OUTRIGGER INSTALLATION.
SE E
C 5
SH EE
T FO
R C
EI LI
N G
H EI
G H
6" VINYL BASE
5/8" GYP. BOARD
5/8" GYP. BOARD
5/8" GYP. BOARD
"
NOTE: ALTERNATIVE FLUSH MOUNT "DANBACK" (CLARKDIETRICH) "FLEXIBLE WOOD" BACKING SYSTEM. IF THE ASSIGNED ARCHITECH/ENGINEER ELECTS TO USE THE ABOVE-MENTIONED APPLICATION, IT IS THEIR RESPONSIBILITY: TO ENSURE THE STUD WALL IS CONSTRUCTED PER USG CONTRUCTION WORKERS GUIDED AND/OR ASTM C745, THE MOUNTING SYSTEM IS INSTALLED PER DANBACK SPECIFICATIONS AND ANY ADDITIONAL WALL LOADS, NOT RELATED TO THE OUTRIGGER INSTALLATION HAVE BEEN TAKEN INTO STRUCTURAL CONSIDERATIONS.
DANBACK SYSTEM
C
NOTE: ARCHITECT/ENGINEER OF RECORD TO CHOOSE THE ATTACHMENT METHOD THAT BEST SUITS THE SITE SPECIFIC CONDITIONS.
12
' - 0
Store Number
Planned By
Deal Type
As indicated
C3 EL
03/11/21 KTL
JR/DEM
NOT TO SCALEC3 4B
TYPICAL CORNER BOXOUT SECTION
NOT TO SCALEC3 10
TYPICAL LOCKING STORAGE CAGE
NOT TO SCALEC3 8
TYPICAL CARRIAGE FLOOR BUMPER
NOT TO SCALEC3 5
NOT TO SCALEC3 01
NOT TO SCALEC3 03 TYPICAL SECTION AT SOFFIT
NOT TO SCALEC3 05
TYPICAL SECTION @ TOP CHANNEL
NOT TO SCALEC3 2
NOT TO SCALEC3 2A
TYPICAL COLUMN DETAILS (ACT)
NOT TO SCALEC3 3A
TYPICAL SLATWALL COLUMN (ACT)
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
NOT TO SCALEC3 00
341
303
305
303
305
341
305
C EI
LI N
G O
R R
O O
F D
EC K
EX TE
N D
W AL
LS T
O U
N D
ER SI
D E
O F
4 ' - 6"
4' -
6"
341 305
METAL STUD AND DRY WALL CONSTRUCTION
NOTE: ALL VERTICALLY TILED OUTSIDE CORNERS WITHIN THE RESTROOM TO BE FINISHED WITH SCHLUTER SYSTEM "RONDEC" PROFILE. (RO80AE FOR 8MM TILE)
INSTALL POWERED FAUCETS AT ALL SINKS, REFER TO TJX SPECIFICATION MANUAL,
INSTALL FLUSHOMETERS ON ALL WATER CLOSETS AND URINALS, REFER TO TJX SPECIFICATION MANUAL.
ADD URINAL SCREEN SUPPORT POST FROM FLOOR TO CEILING, IF REQUIRED. COORDINATE WITH TJX PROJECT MANAGER.
TOILET ACCESSORY LEGEND
1. CUP DISPENSER, MOUNTED AT 40" A.F.F. 2. AUTOMATIC SOAP DISPENSER, MOUNTED AT 40" A.F.F. (AT
THE OPERATING POINT.) 3. XLERATOR XL-SB ELECTRIC HAND DRYER, MOUNTED AT
40" A.F.F. (AT THE OPERATING POINT.) INSTALL XCHANGER COMBO KIT #40576.
4. OPTIONAL SANITARY NAPKIN DISPENSER, MOUNTED AT 40" A.F.F. (AT THE OPERATING POINT.) (DO NOT THRU BOLT INTO PARTITION.)
5. SANITARY NAPKIN DISPOSAL @ 15" A.F.F. 6. 5'-0" HIGH, 1/4" PLATE GLASS MIRROR OVER ENTIRE
WIDTH OF SINK COUNTERTOP. EDGE PROTECTED WITH 1/4" J-MOLDING. BOTTOM MOUNTED AT 38" A.F.F. (TOP OF BACKSPLASH)
7. DEODORANT HOLDER @ 96" A.F.F. 8. 36" GRAB BAR @ 36" A.F.F. 9. 42" GRAB BAR @ 36" A.F.F. 10. TOILET PAPER HOLDER @ 21" A.F.F. WITH DISPENSING
POINT LOCATED 7" TO 9" IN FRONT OF TOILET 11. SEAT COVER DISPENSER @ 40" A.F.F. DISPENSING @ 48"
A.F.F. 12. ASI 0458-DX SEMI-RECESSED WASTE RECEPTACLE. 13. TOILET PARTITION BY GLOBAL STEEL PRODUCTS. COLOR:
CHARCOAL #2123. PARTITION DOORS TO HAVE SOLID WOOD CORES. ALL PARTITION DOORS TO HAVE A COAT HOOK / BUMPER, MOUNT 48” MAX. AT HP STALL DOORS, AND 66” MAX FOR NON HP STALL DOORS.
14. TOP OF TOILET SEAT @ 17"-19" A.F.F. 15. BABY CHANGING STATION MOUNTED WHEN OPEN THE
TOP SURFACE IS 33" A.F.F. WHEN CLOSED THE PULL SHOULD BE NO HIGHER THAN 48" A.F.F.
16. RESTROOM ENTRY THRESHOLD TRANSITION. SCHLUTER RENO-RAMP AERP100B65 (ANODIZED ALUMINUM)
17. URINAL SCREEN BY GLOBAL STEEL PRODUCTS. COLOR: CHARCOAL #2123.
18. 48 INCH HIGH STAINLESS STEEL CORNER GUARDS, AS SUPPLIED BY ATR SALES INC FOR EWC
MEN'S
WOMEN'S
14
10
9
.C .
2
BACKSPLASH
1/2" x 3" PLYWOOD APPLIED HORIZONTAL TO BRACKETS FOR ATTACHMENT OF FRONT PANEL.
DROP-IN LAVATORY SINK OR KITCHENETTE SINK
BLOCKING AS REQUIRED
G.C. TO FASTEN WITH STAINLESS STEEL SCREWS AND GROMMETS.
NOTE: G.C. MUST INSTALL LAMINATED SKIRT PANEL AS SHOWN TO MEET ADA DIMENSIONAL CLEARANCES (NOTIFY PROJECT MANAGER IF FIELD CONDITIONS PROHIBIT INSTALLATION.)
• RESTROOM COUNTER • LAMINATE FRONT BOTTOM EDGE
• KITCHENETTE COUNTER • LAMINATE FRONT BOTTOM EDGE
POSTFORM LAMINATED COUNTERTOP FINISH NOTE:
• RESTROOM SKIRT
FINISH NOTE:
318 FINISH NOTE:
5
/8 "
2"
3/4" PLYWOOD BRACKET SUPPORTS. (1) AT EACH END OF TOP & (1) AT MIDPOINT.
4
RAKKS #EH1818 SUPPORT BRACKET (CLEAR ANODIZED)
NOTE: FOR STANDARD 6' - 6" LENGTH TOP (3) SUPPORT BRACKETS ARE REQUIRED - SPACE EVENLY. IF STANDARD LENGTH DOES NOT APPLY, SPACING/AMOUNT OF SUPPORT BRACKETS TO BE DETERMINED BY TJX P.M.
FINISHED FLOOR
BUILD OUT 1/2"
3
A
2
2
5' -
6"
CORNER GUARDS (TYP) @ ALL 90° CORNERS SHALL RECEIVE PAWLING CLEAR LEXAN STYLE #CG-17, 1 1/8" X 1 1/8" X 4'-0" LENGTH (EXCEPT BOXED COLUMNS AT 5'-0" A.F.F.). NO SUBSTITUTIONS. ALL CORNER GUARDS TO BE FASTENED TO WALL WITH SCREWS. NO ADHESIVES.
NOTE: ALL DOORS AND FRAMES NOT SHOWN ON THE ELEVATION SHEET (C4) TO BE PAINTED SAME COLOR AS SALES FLOOR DOORS AND FRAMES.
SPECIFICATIONS FOR V.W.C. INSTALLATION
NEW CONSTRUCTION: THE G.C. SHALL SEE THAT SURFACES PRESENT A TRUE SMOOTH, LEVEL FINISH FREE FROM CRACKS, DIRT, DUST, RREGULARITIES, ROUGH SPOTS AND INDENTATIONS. A GOOD QUALITY NAMED BRAND WHITE OIL BASED PRIMER SHALL BE USED ON ALL NEW DRYWALL TO EASE APPLICATION AND FUTURE REMOVAL.
RENOVATIONS: OLD WALLCOVERING SHALL BE REMOVED AND WALLS ARE TO BE WASHED AND SANDED TO REMOVE ANY OLD ADHESIVE. IF NECESSARY THEY SHALL BE RE-PRIMED WITH AN OIL BASED WHITE PRIMER.
ADHESIVE: GUARD FC-100 OR ANY OTHER GOOD QUALITY HEAVY DUTY ADHESIVE IS RECOMMENDED.
DO NOT "RAILROAD" VINYL WALL COVERING.
ALL WORK SHALL BE COMPLETED IN A NEAT AND PROFESSIONAL MANNER.
AF F
325
SLATWALL PANEL SYSTEMS:
REFER TO SECTION 6A OF THE OUTLINE SPECIFICATION FOR WORK RESPONSIBILITY REGARDING SLATWALL PANEL SYSTEM.
INSTALLATION INSTRUCTIONS FOR PREFABRICATED WALL PANEL (SLATWALL) AND METAL SLATWALL COMPONENTS ARE INCLUDED AS A PART OF THE PACKAGE. IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO BECOME FAMILIAR WITH THESE INSTRUCTIONS PRIOR TO PROVIDING A PRICE OR COMMENCEMENT OF WORK.
8" REVERSE CUT WHITE VINYL LOGOTO 36" A.F.F. 325
3
6 "
AF F
PANEL LEGEND
PANELS DIMENSIONS ILLUSTRATE THE CENTER LOCATION OF METAL UPRIGHT. SEE FOR MFG. INSTRUCTIONS FOR INSTALLATION.
DIMENSION SEE PLAN FOR
11/16" X 1-1/2" x 8'-1" PAINTED PRMD MDF BOARD (TYP)
PAINT 1 ½" GAP
MIRROR EDGES FINISHED WITH L-BAR IN SATIN FINISH, 5/8"X 3/8".
DRESSING ROOM
11/16" X 1-1/2" x 8'-1" PAINTED PRMD MDF BOARD (TYP)
303
EXTENT OF WALL TILE
27" MIN (H) OF KNEE SPACE UNDER SINK (MEASURED FROM A POINT 8" FROM THE FRONT EDGE OF THE COUNTER EXCLUDING THE OVERFLOW)
9" MIN (H) OF TOE SPACE THAT EXTENDS 17" MIN UNDER THE SINK (MEASURED FROM THE FRONT EDGE OF THE COUNTER.)
A 30" X 48" CLEAR FLOOR SPACE AT THE ACCESSIBLE SINK THAT EXTENDS 17" MIN UNDER THE COUNTER.
PIPES AT ACCESSIBLE SINK MUST BE INSULATED.
TOILET PARTITION
EDGE OF WALL DUE TO TILE ON THE
ADJACENT WALL
34" MAX A.F.F. WITH 4" BACKSPLASH.
6
339
BULLNOSE
339
130
303
MIN 4"6' - 1"40' - 5"
G.C. NOTES: UPPER GLAZING @ DOOR TRANSOMS ON SALES SIDE SHALL RETAIN A 1" GAP BETWEEN GLAZING AND VERTICAL FRAMES TO ELIMINATE NEGATIVE AIR PRESSURE IN VESTIBULE. GLASS TO BE RADIUSED AND GROUND SMOOTH ON BOTH SIDES.
BUMPER RAIL @ 40 1/2" A.F.F.
341 341 341 341 341
303 303
314
EQEQ
8' -
4"
MIN 4"
MIN 4"8' - 1"3' - 0 1/2"
MIN 7"
341 341
341
MIN 5 1/2"
MIN 4"
- 48 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
- 36 ½" OUTRIGGER3 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER8 SEE DETAIL 00/C3 FOR INSTALLATION
- 36 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
11/16" X 1-1/2" x 8'-1" PRMD MDF BOARD PAINTED #303 (TYP
BUMPER RAIL @ 24" & 6 1/2" AFF
SEE DETAIL 7/C4 FOR DRESSING ROOM
INTERIOR FINISHES.
303 303
303 RETURN
9' -
0"
8' -
6"
10 ' -
6 "
MIN 4" 8' - 1" 6' - 1" 1' - 4" 1' - 6"20' - 2 1/2"
MIN 4" 1' - 6" 12' - 1 1/2"
MIN 4" 1' - 6" 1' - 6"
4' - 0 1/2" MIN 4"
- 48 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
- 36 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER5 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER3 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER1 SEE DETAIL 00/C3 FOR INSTALLATION
341 341 341 341 341
341
305
305
10 ' -
6 "
2' -
6"
303 303 303
EQEQ
10 ' -
6 "
MIN 4"
4' - 0 1/2" 9' - 1 1/2" 2' - 0" 1' - 6" MIN 4" 44' - 5 1/2" 3' - 0 1/2"
MIN 4"
BUMPER RAIL @ 40 1/2" A.F.F.
314
341
305
303
Scale
Date
Store Number
Planned By
Deal Type
As indicated
C4 EL
03/11/21 KTL
INTERIOR ELEVATIONS
NEWPORT, TN
JR/DEM
NOT TO SCALEC4 1A
TYPICAL SECTION @ COUNTER TOP
NOT TO SCALEC4 1B
NOT TO SCALEC4 7
NOT TO SCALEC4 8
NOT TO SCALEC4 9
MARSHALLS FINISH SHEDULE FINISH
TILE ARMSTRONG STANDARD EXCELON #51810 WASHED
LINEN 108 VINYL COMPOSITION
TILE ARMSTRONG STANDARD EXCELON #57501 NOUGAT
112 PAINT BENJAMIN MOORE #0P22 SUPER SPEC URETHANE ALKYD GLOSS ENAMEL BASE: 3B / COLOR: DECK GRAY WITH SAND ADDED FOR NON-SLIP FINISH
113 PAINT BENJAMIN MOORE REGAL #968 "DUNE WHITE" (SEMI-GLOSS 333)
115 ENTRANCE GRID MATTING
MATWORKS AMBASSADOR - TF - CHARCOAL WITH TF TAPE
117 PAINT BENJAMIN MOORE #OC-161 "CEDAR KEY" (SEMI-GLOSS) 130 COVE BASE SCHLUTER
SYSTEMS DILEX-AHK (AHK1S100AE), MATERIAL: SATIN ANODIZED ALUMINUM, SIZE: 100 (3/8 - 10 MM). OUTSIDE CORNERS 90 DEGREES - E90/AHK1S100AE STAIN ALUMINUM. CUSTOMER SERVICE 800-472-4588
137 EIFS DRYVIT #310 "CHINA WHITE" 138 PAINT BENJAMIN MOORE CLOUD WHITE #967. PAINT TO MATCH
CHINA WHITE DRYVIT. (EGGSHELL) 211 NON-SLIP VINYL
COMPOSITION ARMSTRONG SLIP RETARDANT #57005 STONE BEIGE
TILE 218 CORNER GUARD PAWLING CLEAR LEXAN STYLE #CG-17, 1 1/8" X 1
1/8" X 4'-0" LENGTH ALL CORNER GUARDS TO BE FASTENED TO WALL WITH SCREWS. NO ADHESIVES.
219 CORNER GUARD WINDMILL INSIDE/OUTSIDE CORNER MOULDING, #3652 COLOR: (FOR SLATWALL COLUMNS IN MXMR) WHITE - NO SUBSTITUTIONS
238 LAMINATE FORMICA POSTFORMED SURFACE, #86992-58 HARDROCK MAPLE
251 VINYL BUMPER RAIL MCCUE #609 "DARK PUTTY", 2" IN DIAMETER 303 PAINT BENJAMIN MOORE #0C-65 "CHANTILLY LACE",
- OFFICES, DOORS/FRAMES, RESTROOMS, COLUMNS & SUPPORT (SEMI-GLOSS) - SALES FLOOR & EXTERIOR (EGGSHELL)
304 PAINT BENJAMIN MOORE #OC-68 "DISTANT GRAY" (SEMI-GLOSS) 305 PAINT BENJAMIN MOORE #2061-20 "CHAMPION COBALT"
(EGGSHELL) 308 VINYL COMPOSITION
TILE ARMSTRONG #51899 COOL WHITE, 12" X 12" X 1/8"
IMPERIAL TEXTURE 311 LUXURY VINYL TILE AMTICO W684 - MAPLE (NON-BEVELED EDGE)
6"x36" PLANK IN 3.2 MM THICKNESS (1/8") 312 LUXURY VINYL TILE AMTICO W738 - PALISANDER (NON-BEVELED
EDGE) 6"x36" PLANK IN 3.2 MM THICKNESS (1/8")
313 VINYL BUMPER RAIL MCCUE #111 SILVER, 2" DIAMETER 314 VINYL BUMPER RAIL MCCUE #111 SILVER, 1" DIAMETER 315 BEAD BOARD WALL
SYSTEM DGS RETAIL MARSHALLS HOME AREA BEAD BOARD
WALL SYSTEM 317 LAMINATED PANEL DGS RETAIL #1573-60 FROSTY WHITE 318 PLASTIC LAMINATE WILSONART POSTFORMED SURFACE #4779-60
PEWTER BRUSH 303. LAVATORIES SHALL BE MOUNTED SELF RIMMING VITREOUS CHINA WITH 8" CENTER SET SUPPLY WITH AERATOR, AND A FLAT PERFORATED STRAINER LAVATORY WASTE DRAIN.
319 LAMINATE (FRONT-LINE)
322 DOUBLE SLOTTED SLATWALL
DGS RETAIL BAUSCH LINNEMANN HARDROCK MAPLE WM791 SUEDE 6" SLAT PANELS
323 FRP MARLITE STANDARD FRP FINISH, PEBBLED SURFACE, P100 WHITE. 4'-0" HIGH WAINSCOTING ON ALL WALLS (EXCLUDING NYC RESTROOMS, GOES TO CEILING AND 8'-0" HIGH WAINSCOTING ABOVE MOP SINK AREA ONLY)
324 LAMINATE PANEL WILSONART #1573-60 "FROSTY WHITE" 325 VINYL DGS RETAIL INC. MARSHALLS - 3M DARK BLUE 326 SPANDREL GLASS SOLAR SEAL
COMPANY 1" CLEAR/CLEAR WITH SPANDREL. 1/4" CLEAR WITH 6-0025 HARMONY BLUE (2). 1/2" AIR SPACER. 1/4" CLEAR
327 EIFS DRYVIT #449 "BUCKSKIN" (SANDBLAST) 328 PAINT BENJAMIN MOORE #965 "TEMPORAL SPIRIT". PAINT TO
MATCH "BUCKSKIN" DRYVIT. (EGGSHELL) 329 EIFS DRYVIT #112 "SANDLEWOOD BEIGE" (SANDBLAST) 330 EIFS DRYVIT #578 "MIDNIGHT BLUE" (SANDBLAST) 332 CROWN MOULDING N/A WPRB3-PFJ PRIMED PINE 830345 CASING,
PAINT #304 333 BEAD BOARD DGS RETAIL INC. 1/2" UNIVERSAL BEAD BOARD WALL
COVER PANEL 334 WALLCOVERING MDC
WALLCOVERING CANDACE OLSEN, "ROMANCE EBONY" #TJX 2107 (MENS) NOTE: WALL COVERING TO MATCH UP AT REPEATS
335 WALLCOVERING MDC WALLCOVERING
CANDACE OLSEN, "ROMANCE STEEL" #TJX 2112 (WOMENS) NOTE: WALL COVERING TO MATCH UP AT REPEATS
336 VINYL BUMPER RAIL MCCUE ANTIQUE RED FAUX BRICK 337 VINYL BUMPER RAIL MCCUE BRIGHT WHITE FAUX BRICK 338 LAMINATED PANEL SUNBRELLA MARINE BLUE 339 CERAMIC TILE DALTILE 12" X 12" DB VOLUME 1.0, STEREO GREY,
WALL TILE #VL73, INSTALLED VERTICALLY. WITH 3" X 12" MATCHING BULLNOSE MOLDING #P-43C9. GROUT BY LATICRETE, #89 "SMOKE GREY" (3/16").
340 CERAMIC TILE DALTILE 12" X 12" DB INDUSTRIAL PARK, CHARCOAL GRAY, FLOOR TILE #IP09. GROUT BY LATICRETE, #42 "PLATINUM" (3/16").
341 VINYL COVE BASE TARKETT TA4 "GATEWAY", 6" 342 VINYL COVE BASE TARKETT #31 "ZEPHYR", 6" 343 PAINT BENJAMIN MOORE #110 CORONADO SUPER KOAT 500 DRY
FALL LATEX PAINT FLAT, TINTED TO BENJAMIN MOORE, #OC 65 "CHANTILLY LACE".
407 VINYL BUMPER RAIL MCCUE #604 LIGHT CARAMEL, 1" DIA.
NOT TO SCALE0A PARTIAL ELEVATION AT ENTRANCE
NOT TO SCALE0B SECTION AT ENTRANCE
NOT TO SCALEC4 A
NOT TO SCALEC4 D TYPICAL WALL ELEVATION
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
NOT TO SCALEC4 C HAND DRYER ELEVATION
1/8" = 1'-0"C4 01 FRONT LINE ELEVATION
1/8" = 1'-0"C4 02 SHOES A ELEVATION
1/8" = 1'-0"C4 03 SHOES B ELEVATION
1/8" = 1'-0"C4 04 DRESSING ROOM ELEVATION
1/8" = 1'-0"C4 05 HOME ELEVATION
1/8" = 1'-0"C4 06 KID'S & MEN'S ELEVATION
NOT TO SCALEC4 00 STORE LOGO
E
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
END
A
T4L (TYP. OF 9)
T4L (TYP. OF 9)
G3 G3 G3
A6 A6
A6 A6
A6 A6
BABY
NL A A A
L1 L1
120" AFF
ALL SOFFIT, VALANCE, DISPLAY, & FOCAL WALL LIGHTING TO BE CONSIDERED "CUSTOMER LIGHTING" & CONTROLLED BY NOVAR, THROUGH THE CONTACTOR RELAY PANEL.
ALL TRACK IS TO BE MOUNTED ON UNISTRUT. ALL UNISTRUT TO BE PAINTED WHITE AND HUNG AS REQUIRED FROM STRUCTURE ABOVE. ALL TRACK USED IN THE STORE IS TO BE WIRED FROM 120V PANEL.
ELECTRICAL J-BOX FOR ALL OVERHEAD TYPE LIGHTS TO BE WITHIN 4' OF EACH ACTUAL LIGHT FIXTURE.
PAINT # 343 UNDERSIDE OF DECK, ALL EXPOSED PIPES, DUCTS, CABLES, CONDUITS, UNISTRUT, ETC.
2" WIDE UNISTRUT SUPPORTED FROM STRUCTURE ABOVE. BOTTOM OF UNISTRUT FOR SIGNAGE MOUNTED 12'-0" A.F.F. GC TO COORDINATE EXACT PLACEMENT WITH TJX PROJECT MANAGER AND FIELD OPERATIONS.
NOTE: TIE HALL LIGHTS IN WITH EMPLOYEE LIGHTING CIRCUIT
CEILING HEIGHT = 10' - 2" A.F.F.
A.C.T. CEILING HEIGHT = 10' - 6" A.F.F.
TOP OF TRACK TO BE INSTALLED 8" HIGHER THAN GENERAL LIGHTING.
ALL TRACK IS TO BE MOUNTED ON UNISTRUT.
ALL UNISTRUT TO BE PAINTED WHITE AND HUNG AS REQUIRED FROM STRUCTURE ABOVE.
ALL TRACK USED IN THE STORE IS TO BE WIRED FROM 120V PANEL.
NOTE: LIGHTING PATTERN MUST REMAIN AS DRAWN AND ADHERE TO THIS PLAN. ALL LIGHT FIXTURES IN SALES AREA WILL BE MOUNTED @ 12' - 0" A.F.F. TO THE UNDERSIDE OF THE FIXTURE. (SEE EXCEPTIONS). LANDLORD ARCHITECT MUST COORDINATE ALL M.E.P. TRADES TO ENSURE. PLEASE CONTACT TJX PROJECT MANAGER AND M.O.D. IMMEDIATELY IF THERE ARE ANY FIXTURE SPACING OR MOUNTING HEIGHT CONFLICTS. TJX WILL NOT BE RESPONSIBLE FOR COSTS INCURRED FOR INCORRECT INSTALLATION AND MOUNTING OF LIGHT FIXTURES WITHOUT PRIOR NOTIFICATION TO TJX P.M. OR M.O.D..
LIGHTS TO BE MOUNTED AT 12' - 0 " A.F.F. MECHANICAL, ELECTRICAL, AND PLUMBING TO BE MOUNTED WITH ADEQUATE CLEARANCE BETWEEN TOP OF LIGHTING FIXTURES AND ROOF DECK.
WHEN DIMMING IS REQUIRED BY LOCAL JURISDICTION, REFER TO TITLE 24 MEP EXAMPLE PLANS.
2 C5
2 C5
1
2
3
4
5
3' -
8' -
T4L (TYP. 1 THRU 9) T4L (TYP. 1 THRU 9)
POSITION TRACK HEADS 2, 5 AND 8
TO ILLUMINATE GRAPHICS
CROSS-ILLUMINATE MERCHANDISE
S E
E C
5 S
H E
E T
FO R
C EI
LI N
G H
EI G
H T
2' X 4' ACOUSTICAL SUSPENDED CEILING OVER VESTIBULE
2
SE E
C 5
FO R
LI G
H T
FI XT
U R
E H
EI G
H T
3' - 6"
EST. YEAR
SE E
C 4
FO R
M O
U TI
N G
H EI
G H
3' - 6"
SE E
C 5
FO R
LI G
H T
FI XT
U R
E H
EI G
H T
CITY NAME
SINGLE OCCUPANCY SENSOR SWITCH (PIR) (REFER TO TJX SPECIFICATIONS FOR PRODUCT INFORMATION.)
SINGLE POLE SWITCH.
LEGEND
UNISTRUT
LIGHTING NOTES:
1. STORE LIGHTING (SALES & SUPPORT) SHALL INCORPORATE QUANTUM ELM2 TYPE FIXTURES TO ACT AS EMERGENCY LIGHTS. NUMBER OF FIXTURES TO BE DETERMINED BY CODE.
2. NL-FIXTURES WILL BE WIRED BEFORE A SWITCH OR CONTACTOR. (FIXTURES WILL RUN 24 HOURS)
3. LAYAWAY STOCK & PROCESSING ROOM LIGHTING TO BE MOUNTED AT 13' AFF. (LIGHTING TO BE COORDINATED WITH HVAC & STRUCTURAL STEEL)
4. TYPE A4 PENDANT LIGHTING FITTED WITH LOCKING PLUG. (NEMA L5-20P 20A, 125V, NEMA L7-20P 20A, 277V) E.C. TO FURNISH AND INSTALL APPROVED LOCKING RECEPTACLE AT OPEN DECK CEILING, PER REQUIRED VOLTAGE. (NEMA L5-20R 20A, 125V, NEMA L7-20R 20A, 277V)
5. HANGING SIGNS PROVIDED AND INSTALLED BY TJX.
6. SECURE EXCESS CORD WITH TIE STRAP ABOVE LIGHT FIXTURE. COORDINATE WITH TJX PROJECT MANAGER.
A6 AIMING ANGLE TABLE Mounting Height (Ceiling Height)
Distance off the Wall Desired Angle
10'-0" 3'-6" 41°
11'-0" 3'-6" 35°
12'-0" 3'-6" 30°
13'-0" 3'-6" 27°
14'-0" 3'-6" 24°
15'-0" 3'-6" 21°
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C5 EL
03/11/21 KTL
JR/DEM
SYSTEM WATTAGE
SYSTEM VOLTAGE
SPECIFICATION NUMBER (ORDERING INFORMATION) COMMENTS
A 188 2' X 4' 37 MULTI-VOLTAGE RECESSED LED ACUITY (LITHONIA)
2ESL4 48L EZ1 LP835 NATJ
A6 52 5-1/2" X 3-7/8" 57 120V TRACK LED CONTECH CTL184V35D-P SEE AIMING ANGLE TABLE, C5 SHEET. B 1 DOCKLIGHT 18 120V WALL
MOUNTED LED CRESENT DCF40CP3 (Dock Swing Arm),
LED18DP38W830/25 (GE Lamp) DOCKLIGHT
D 4 2' X 4' 37 MULTI-VOLTAGE RECESSED LED ACUITY (LITHONIA)
2ESL4 F 48L EZ1 LP835 NATJ FOR GYPSUM BOARD CEILINGS, AND FLANGE KITS
E 6 EXIT SIGN 4.3 MULTI-VOLTAGE WALL MOUNTED
LED ACUITY (LITHONIA)
LHQM-LED-R-120/277 QUANTUM LHQM EXIT SIGN/EMERGENCY LIGHT COMBO
F3 1 4" X 8' 53.4 MULTI-VOLTAGE SURFACE LED HUBBELL (COLUMBIA)
LSRK8-4W-40VW-FA-EDU-HSG8-CSHC
G3 11 4" X 8' 53.4 MULTI-VOLTAGE PENDANT LED HUBBELL (COLUMBIA)
LSRK8-4W-40VW-FA-EDU-HSG8-CSHC REQUIRES INDEPENDENT SUPPORTS TO THE STRUCTURE EVERY 4'-0
L 3 16" X 9-5/8" 32 MULTI-VOLTAGE WALL MOUNTED
LED EATON (SURELITE)
LDWP-GL-4B-ED-EMLED-CD MOUNT FIXTURE AT 7'-6" AFF OR PER LOCAL CODE
L1 13 16" X 9-5/8" 32 MULTI-VOLTAGE WALL MOUNTED
LED EATON (SURELITE)
LDWP-GL-4B-ED MOUNT FIXTURE AT 7'-6" AFF OR PER LOCAL CODE
O7 26 2' X 2' 20.2 MULTI-VOLTAGE RECESSED LED ACUITY (LITHONIA)
2RTL2 20L EZ1 LP830
R 49 EMERGENCY 1.5 MULTI-VOLTAGE SURFACE LED ACUITY (LITHONIA)
ELM2L CAN USE ELM6-LED, ELM-LT, or other Emergency lights in the Acquity ELM family
T4L 60 2-7/8" X 2-1/16" 17 120V TRACK LED PHILIPS/CONT ECH
CTL603-P (LAMP HOLDER), 435362 (PHILIPS LAMP)
TRACK MOUNTED SPOT LIGHT, 17PAR38/S15 3000 DIM AF SO
NOT TO SCALE
NOT TO SCALEC5 2
NOT TO SCALE
NOT TO SCALE
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
144"
18" B
54" 18"
FOCAL WALL SAVING NEVER LOOKED SO GOOD
FO CA
L W
AL L
LO VE
T HE
L AB
EL A
ND T
HE P
RI CE
FO CA
L W
AL L
BR AN
D NA
M ES
F OR
L ES
41"
J
J
B
D
B
C
B
E
T
S
F
J
PP
B
F
DEDICATED DUPLEX RECEPTACLE AT 12" A.F.C. FOR STORE SECURITY SYSTEM NOTE: LOCATED NEAR THE DOOR
COORDINATE EXACT LOCATIONS WITH TJX PROJECT MANAGER.
WEATHERPROOF PUSH BUTTON (SEE SPEC. DWG. C7)
REAR DOOR ALARM (SEE SPEC. DWG. C7)
OUTLET AT 18" A.F.F. FOR REWRAP TABLE
DUPLEX RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON THE SAME CIRCUIT THROUGHOUT CASH REGISTER AREA. (TYP.)
DEDICATED LINE WITH APPROPRIATE VOLTAGE AND DISCONNECT FOR FINAL CONNECTION TO COMPACTOR. 460V REQUIRES A 30 AMP DISCONNECT, 208V OR 230V REQUIRES A 60 AMP DISCONNECT. ELECTRICAL RUN AND A FUSED DISCONNECT WILL BE INSTALLED ON THE OUTSIDE OF THE BUILDING WITHIN 50' AND IN CLEAR SIGHT OF THE UNIT.
COORDINATE "WALL MOUNTED" ELECTRICAL WITH CASH CABINET LOCATION. IF STOREFRONT GLASS EXISTS BEHIND CABINET, FIELD VERIFY MOUNTING HEIGHT OF ELECTRICAL WITH TJX PROJECT MANAGER.
G.C. TO COORDINATE ELECTRIFIED STORE FIXTURES WITH DEPARTMENT LAYOUTS FROM THE FINAL FIXTURE PLAN.
EXTERIOR SIGN: FOR EACH EXTERIOR SIGN, ELECT. CONTRACTOR SHALL PROVIDE (3) 20 AMP, 120 VOLT CIRCUITS TO (3) THREE-GANG BOXES. MIDDLE J-BOX CENTERED ON SIGN FIELD. REMAINING J-BOXES AT 10'-0" TO CENTERLINE, EITHER SIDE. CONTROLLED BY BMS CONTACTOR. COORDINATE EXACT LOCATION OF CIRCUITS WITH TJX SIGN VENDOR AND TJX PM. SEE SPEC 16A.
PROVIDE CONDUIT AND (2) J- BOXES WITH BLANK PLATES AT LOCATION OF FIRE ALARM PANEL.
THREE (3) 2 1/2" CONDUITS TO BE CONCEALED IN FLOOR & WALL ON SALES AREA SIDE.
CONDUIT TERMINATION POINT. LOCATED UNDER CASH REGISTER COUNTER.
J-BOX FOR DRESSING ROOM MIRRORS (TYP.) CONNECT TO CUSTOMER LIGHTING CIRCUIT.
COORDINATE HEIGHT & LOCATION FOR ELECTRIC DRYER WITH TJX PROJECT MANAGER
NOTE: VERIFY ELECTRIC STRIKE LOCATION WITH MARSHALLS PROJECT MANAGER FOR EACH PROJECT
EDWARDS SIGNALING BUILDERS CHIME KIT C212 SERIES
OUTLET FOR TIMECLOCK
1 C6
PROVIDE 20 GAL. WATER HEATER W/ QUICK RECOVERY MOUNTED O ABOVE SINK SET TEMP. @ 105 F. TO BE MOUNTED BELOW FINISHED CEILING
COORDINATE EXACT LOCATIONS WITH TJX PROJECT MANAGER.
ALL ELECTRICAL DEVICE COVERS TO BE BRUSHED ALUMINUM
COORDINATE BURGLAR ALARM LOCATION WITH TJX PROJECT MANAGER
3/ 4"
C O
N D
U IT
C O
N N
EC TI
N G
IN TE
R IO
R A
N D
E XT
ER IO
R J
-B O
5' - 11 1/2"
2' -
1/ 2"
3 C6
3 C6
3 C6
SINGLE DEDICATED OUTLET TO BE MOUNTED TO END CHECKOUT UNIT. SEE DETAIL ON C7 SHEET.
DEDICATED OUTLET FOR SODA COOLER
G.F.I.
J-BOX FOR CUSTOMER COUNTER. INSTALL 6" ABOVE BOTTOM OF LIGHT FIXTURE
HEIGHT
DEDICATED DUPLEX OUTLET FOR FUTURE CART CONTAINMENT SYSTEM. (LOCATE 6"
ABOVE VESTIBULE FINISHED CEILING) CENTERED BETWEEN INTERIOR DOORS.
CONTINUOUSLY ELECTRIFIED AND NOT CONTROLLED BY A SWITCH
NOTES:
G.C. RESPONSIBLE TO CONTRACT "STANLEY ACCESS TECHNOLOGIES" TO PROVIDE & INSTALL VESTIBULE DOORS.
G.C. / E.C. RESPONSIBLE FOR ALL FINAL CONNECTIONS TO DOORS.
G.C. ELECTRICIAN TO PROVIDE (1) 120 V. 20 AMP DEDICATED CIRCUIT FOR THE
INTERIOR SET OF DOORS AND (1) 120 V. 20 AMP DEDICATED CIRCUIT FOR THE
EXTERIOR SET OF DOORS. ( LOCATE 6"ABOVE FINISHED CEILING) (1) 10 AMP LINE
TO EACH DOOR OPERATOR. ELECTRICAL TERMINATIONS BY E.C.
G.C. / E.C. TO PROVIDE A 110 VAC, CONTINUOUSLY ELECTRIFIED AND NOT CONTROLLED BY A SWITCH, QUAD OUTLET AT THE CONDUIT TERMINATION POINT ABOVE THE VESTIBULE CEILING. G.C. / E.C. TO PROVIDE AN 18" x 18" (MINIMUM) ACCESS PANEL AT THIS LOCATION IN THE EVENT THE VESTIBULE IS A HARD CEILING.
6' - 0" ± 3' - 4" 6' - 0"
1" CONDUIT INSTALLED FROM JUNCTION BOX TO MULLION. CONDUIT WILL START AT THE JUNCTION BOX AND WILL ROUTE ACROSS THE FLOOR TO THE MULLION IN THE VESTIBULE. CONDUIT WILL TRANSITION FROM THE FLOOR TO THE INSIDE OF THE MULLION. CONDUIT WILL ROUTE UP THE INSIDE OF THE MULLION TO THE VESTIBULE CEILING ABOVE. CONDUIT WILL TERMINATE APROX 6" ABOVE THE VESTIBULE CEILING AT THE AC OUTLET LOCATION.
JUNCTION BOXES TO BE INSTALLED PERPENDICULAR TO THE SLIDING DOOR FRAMES. JUNCTION BOXES (WITH COVERS) TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR. JUNCTION BOXES TO BE INSTALLED AT 24" (2'-0") BACK FROM THE INSIDE SLIDING DOOR EDGE TO THE CENTER OF THE JUNCTION BOX. JUNCTION BOXES TO BE INSTALLED AT 72" (6'-0" CENTER TO CENTER, ALIGNED WITH THE EDGE OF THE DOOR OPENING.
2' -
0"
LOW VOLTAGE WIRING CONDUIT & JUNCTION BOX BY G.C. W/PULL WIRE. (WIRING BY OTHERS)
POWER POLE
EXTERIOR SIGN JUNCTION BOX.
CHIME WITH LOW VOLTAGE TRANSFORMER CENTERLINE 94" AFF, UNLESS OTHERWISE NOTED.
BELL WITH LOW VOLTAGE TRANSFORMER, CENTERLINE 90" AFF.
TELEPHONE-DESK SET.
TELEPHONE-WALL HUNG.
DUPLEX RECEPTACLE WITH ISOLATED GROUND.
QUADRUPLEX RECEPTACLE WITH ISOLATED GROUND
BLANKED OUTLET WITH 3/4" EMT RUN UP WALL TO ABOVE SUSPENDED CEILING. HEIGHT AS NOTED.
QUADRUPLEX OUTLET
QUADRUPLEX RECEPTACLE
DUPLEX RECEPTACLE
SIMPLEX RECEPTACLE
EXHAUST FAN
ELECTRIC STRIKE
COMPACTOR DISCONNECT
PHONE/DATA JACK
DOOR BUZZER
SIMPLEX OUTLET
PLUG MOULDING
NEMA RECEPTACLE
RESTROOM, LOUNGE, JANITOR, & DRESSING ROOM (WHEN APPLICABLE) EXHAUST FANS, WILL BE A CONTROLLED/SWITCHED CIRCUIT, RUN THROUGH THE GE LIGHTING RELAY PANEL ON THE "EMPLOYEE" CIRCUIT.
WHEN REQUIRED, ELECTRIC ROOM AND/OR SYSTEMS ROOM EXHAUST FANS WILL BE A 24 HOUR LIVE CIRCUIT CONTROLLED BY IN LINE THERMOSTAT SET AT 80° DEGREES. SEE SPEC. BOOK FOR ADDITIONAL INFORMATION.
FINISHED FLOOR
NOTE: MAXIMUM OF 5 FANS PER CIRCUIT.
EACH FAN CONTROLED BY A TIMER SWITCH. SWITCH MOUNTED AT 4'-0" AFF.
FAN SPEC: TPI CACU-24W
FAN AND TIMER SWITCH PURCHASED BY G.C.
TIMER SWITCH
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C6 EL
03/11/21 KTL
POWER PLAN
NEWPORT, TN
JR/DEM
NOT TO SCALEC6 3
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
NOVAR INTERFACE SUMMARY (REFER TO TJX SPECIFICATIONS FOR DETAIL INFORMATION)
1. GENERAL CONTRACTOR A. PROVIDE AND INSTALL A 4'X8' PLYWOOD BACKBOARD IN THE ELECTRIC ROOM FOR NOVAR TO MOUNT
THEIR EQUIPMENT. PHONE AND ETHERNET JACKS FOR THE NOVAR SAVVY CONTROLLER WILL ALSO BE LOCATED ON THIS BOARD BY A SEPARATE TJX VENDOR.
2. MECHANICAL CONTRACTOR A. HORIZONTALLY MOUNT A 2X4 J-BOX WITH CONDUIT (WIREMOLD IF EXPOSED IN FINISHED AREAS) AT THE
LOCATIONS DESIGNATED ON THE NOVAR CONTROLS SITE SPECIFIC PLANS. THE J-BOXES ARE TO BE MOUNTED AT 60" A.F.F. EXCEPT IN FITTING ROOM LOCATIONS WHERE THE J-BOXES ARE TO BE MOUNTED AT 84" A.F.F.. ON THE SALES FLOOR, THE J-BOXES ARE TO BE MOUNTED ON BACK SIDE OF THE COLUMNS WHEN VIEWED FROM FRONT OF STORE.
B. PROVIDE AND INSTALL A PERMANENT STRANDED 18/8 AWG NON SHIELDED CABLE (18/10 IF THE RTU IS EQUIPPED WITH A C02 SENSOR WITH THE UNIT) FROM EACH ROOFTOP UNIT TO THE NOVAR ETM (T- STAT) LOCATION SHOWN ON THE NOVAR PLAN THAT SUPERSEDES ANY MECHANICAL PLAN LOCATIONS.
C. TEMPORARY THERMOSTATS ARE TO BE INSTALLED AT THE ETM LOCATIONS AND THE ROOFTOP UNITS STARTED.
D. HVAC EQUIPMENT ARE TO HAVE HAD A MANUFACTURER'S RECOMMENDED STARTUP PROCEDURE PERFORMED AND BE OPERATIONAL IN ALL MODES BEFORE THE ARRIVAL OF THE NOVAR CONTROLS REPRESENTATIVE FOR THE FINAL NOVAR INSTALLATION.
3. ELECTRICAL CONTRACTOR A. PROVIDE AND INSTALL A THREE PHASE CIRCUIT BREAKER (20 AMPS) FOR THE PHASE MONITOR. THIS
BREAKER MAY BE INSTALLED IN A LIGHTING DISTRIBUTION PANEL IF THE PANEL IS OF THE SAME VOLTAGE AS THE MAIN DISTRIBUTION PANEL.
B. INSTALL THE NOVAR PROVIDED CURRENT TRANSFORMERS (CTS). C. CONNECT ALL CT WIRING TO THE PHASE MONITOR. D. MOUNT AND POWER THE PHASE MONITOR. E. PROVIDE AND INSTALL BMS#1 (20 AMP, 1 POLE BREAKER), BMS#2 (20 AMP, 1 POLE BREAKER), AND BMS #
3 (20 AMP, 1 POLE BREAKER) POWER SUPPLY. THESE BREAKERS MUST ORIGINATE FROM THE SAME PHASE.
F. THE INSTALLATION, PROGRAMMING, AND LABELING OF THE GE SOFTWIRE PANEL IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.
HVAC SUMMARY (REFER TO TJX SPECIFICATIONS FOR DETAIL INFORMATION)
1. HVAC NOVAR INTERFACE (THE HVAC CONTRACTOR'S WORK PRIOR TO THE NOVAR CONTRACTOR'S WORK): A. THERMOSTATS:
a. THE HVAC CONTRACTOR IS TO PROVIDE AND INSTALL A PERMANENT 18/8 (18/10 IF THE RTU IS EQUIPPED WITH A CO2 SENSOR WITH THE UNIT) THERMOSTAT WIRING FROM THE LOW VOLTAGE SECTION OF EACH HVAC UNIT TO THE FINAL LOCATION OF THE THERMOSTAT (LOCATION OF THE THERMOSTATS ARE IN ACCORDANCE WITH THE PLANS PRODUCED BY NOVAR AND SUPERSEDE THE MECHANICAL PRINT LOCATIONS).
b. THE HVAC CONTRACTOR IS TO INSTALL A TEMPORARY THERMOSTAT FOR EACH HVAC UNIT AT THESE LOCATIONS
c. FOR TESTING AND OPERATIONS. d. THE THERMOSTATS ARE TO BE MOUNTED AT 60" A.F.F. EXCEPT IN THE FITTING ROOM WHERE THE
THERMOSTAT IS TO e. BE MOUNTED AT 84" A.F.F.. IF THERMOSTAT LOCATIONS CONFLICTS WITH A PHONE LOCATION,
INSTALL THERMOSTAT f. SIX TO EIGHT INCHES ABOVE THE PHONE. IF PROVIDED, CO2 SENSORS ARE TO BE INSTALLED SIX
INCHES g. DIRECTLY ABOVE THE THERMOSTAT. h. IN COLD WEATHER, THE HVAC CONTRACTOR IS TO PROVIDE AND INSTALL TEMPORARY A
THERMOSTAT FOR RECEIVING HEATERS. B. SMOKE DETECTORS:
a. THE HVAC CONTRACTOR IS TO SUPPLY AND INSTALL SMOKE DETECTORS FOR THE HVAC EQUIPMENT, (AS WELL AS ANY ADDITIONAL DETECTORS REQUIRED BY THE BUILDING AND FIRE OFFICIALS HAVING JURISDICTION AND GOVERNING CODE). THE SMOKE DETECTORS ARE TO BE PHOTOELECTRIC.
2. AIR BALANCING: A. UPON COMPLETION OF THE HVAC SYSTEM, AIR BALANCING IS TO BE PERFORMED BY AN INDEPENDENT
CERTIFIED AIR BALANCING COMPANY. a. THE CERTIFIED AIR BALANCING REPORT IS TO BE SUBMITTED TO THE TJX COMPANIES PROJECT
MANAGER. B. THE DISPOSABLE HVAC FILTERS ARE TO BE CHANGED JUST PRIOR TO THE STORE GRAND OPENING. C. ALL ABANDONED HVAC EQUIPMENT IS TO BE PROPERLY REMOVED AND DISPOSED. D. THE SPACE ABOVE THE CEILING IS NOT TO BE USED AS A RETURN AIR PLENUM. E. ALL EQUIPMENT AND CONTROL DEVICES ARE TO BE APPROPRIATELY IDENTIFIED AND PERMANENTLY
ATTACHED. 3. BASEBOARD HEATERS
A. BASEBOARD HEATERS ARE TO BE FACTORY EQUIPPED WITH INTEGRAL THERMOSTATS AND ARE TO BE INSTALLED IN ALL OFFICES, LOUNGE, RESTROOMS, AND SECURITY OFFICES THAT HAVE AT LEAST ONE OUTSIDE WALL (IN CLIMATE ZONES 4 AND 5).
B. THE CIRCUITING FOR BASEBOARD HEATING IS TO BE THROUGH THE GE RELAY PANEL. 4. VESTIBULE HEATERS
A. ELECTRIC VESTIBULE HEATERS ARE TO BE FACTORY EQUIPPED WITH LOW VOLTAGE CONTROLS, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: POWER CONTRACTORS, LOW VOLTAGE TRANSFORMER AND A TWO WIRE FIELD TERMINATION CONTROL POINT.
5. EXHAUST FANS. EXHAUST FANS ARE TO BE CONTROLLED AS SHOWN ON TJX CRITERIA PLANS AND POWERED VIA EMPLOYEE LIGHT CONTRACTOR ON THE GE SOFTWIRE CONTRACTOR PANEL.
LIGHTING SUMMARY (REFER TO TJX SPECIFICATIONS FOR DETAIL INFORMATION)
1. NIGHT LIGHTING: A. NIGHT LIGHTS ARE TO BE ON 24 HOURS A DAY AND ONLY IN THE SALES AREA.
a. THE CIRCUIT FOR NIGHT LIGHTING IS NOT TO BE CONNECTED TO THE GE RELAY PANEL, OR EMERGENCY LIGHTING. THE NL SHOULD BE ONLY (1) CIRCUIT IN MOST SITUATIONS.
B. NIGHT LIGHTING "RULE OF THUMB" IS (1) NIGHT LIGHT FOR EVERY 3,500 SQUARE FEET OF SALES AREA (ROUND UP), AND SHOULD BE EVENLY DISTRIBUTED. (REFER TO TJX CRITERIA PLAN SHEET (C5) FOR EXACT QUANTITIES & LOCATIONS).
2. EMERGENCY LIGHTING: A. EMERGENCY LIGHTING IS TO BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES AND AT THE
DIRECTION OF THE GOVERNING AUTHORITIES. B. AT A MINIMUM, THE EMERGENCY LIGHTING IS TO BE AS FOLLOWS:
a. ALL ROOMS AND SPACES ARE TO HAVE AT LEAST (1) EMERGENCY LIGHT. b. THE SALES AREA IS TO HAVE (1) EMERGENCY LIGHT PER 2,000 SQUARE FEET OF FLOOR AREA, AND
SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE SPACE. PATHS OF EGRESS SHOULD BE OF PRIMARY COVERAGE.
c. THE STOCK ROOM SHOULD HAVE A MINIMUM OF (4) EMERGENCY LIGHTS. C. THE EMERGENCY LIGHTING SYSTEM AND CIRCUITS ARE NOT TO BE CONNECTED TO THE GE RELAY
PANEL AND THE CIRCUITS ARE TO BE DEDICATED WITH BREAKER LOCKS INSTALLED AT THE PANEL. D. THE EMERGENCY LIGHTS ARE TO BE LITHONIA LIGHTING, MODEL #ELM2, SELF CONTAINED BATTERY
UNITS. 3. SECURITY LIGHTING:
A. EXTERIOR SECURITY LIGHTING INCLUDES EXTERIOR WALL LIGHT PACKS ATTACHED TO THE BUILDING AS NOTED ON THE PLANS. THESE ARE GENERALLY MOUNTED ABOVE ALL EGRESS DOORS FROM THE STORE.
B. THE CIRCUITING FOR THIS IS THROUGH THE GE RELAY PANEL. C. NOVAR WILL CONTROL THIS LIGHTING BY A SEPARATE CHANNEL IN THE RELAY PANEL. THIS LIGHTING IS
OVERRIDDEN BY A LIGHT SENSOR SUPPLIED AND INSTALLED BY NOVAR. 4. SIGNS AND CANOPY LIGHTS:
A. THIS INCLUDES THE BUILDING, MALL, LIGHTED UNDER CANOPY, ETC. SIGNS AS WELL AS ANY CANOPY LIGHTS (IF NOT BEING CONTROLLED BY THE LANDLORD'S HOUSE PANEL).
B. THESE CIRCUITS ARE TO BE RUN THROUGH THE GE RELAY PANEL. C. NOVAR WILL CONTROL THESE CIRCUITS BY A SEPARATE CHANNEL IN THE RELAY PANEL.
5. CUSTOMER LIGHTING: A. SALES AREA:
a. ONE HALF OF THE SALES AREA CEILING LIGHTS (ALTERNATE ROWS). b. ALL PERIMETER LIGHTING. c. ALL PENDANT LIGHTING. d. JEWELRY COUNTER LIGHTING. e. LAMP DEPARTMENT PLUGMOLD (ON WALLS AND FLOOR GONDOLAS). f. FLOOR OUTLETS FOR LAMP DEPARTMENT. g. CEILING MOUNTED CHANDELIER FIXTURE OUTLETS. h. ANY SPECIALTY LIGHTING (I.E. WALL SCONCES, ETC.).
B. OFF SALES AREA: a. PENDANT LIGHTS IN THE FITTING ROOM b. LIGHTED MIRRORS IN THE FITTING ROOM
C. THESE CIRCUITS ARE TO BE RUN THROUGH THE GE RELAY PANEL. 6. EMPLOYEE LIGHTING:
A. EMPLOYEE LIGHTING IS TO INCLUDE ALL (EXCEPT AS EXCLUDED BELOW) INTERIOR STORE LIGHTING AND BE RUN THROUGH THE GE RELAY PANEL. THE SALES AREA CEILING LIGHTS IS TO BE ALTERNATE ROWS.
B. ITEMS NOT INCLUDED IN "EMPLOYEE LIGHTING" ARE NIGHT LIGHTING, EMERGENCY LIGHTING, EXIT LIGHTING, DOCK LIGHTS, "SECURITY LIGHTING", "SIGNS AND CANOPY LIGHTS", AND "CUSTOMER LIGHTING" AS DESCRIBED ABOVE.
C. EMPLOYEE LIGHTING IS TO INCLUDE ALL EXHAUST FANS EXCEPT THE ELECTRICAL ROOM EXHAUST FAN THAT IS TO BE CONTROLLED BY A STAND-ALONE LINE VOLTAGE THERMOSTAT (SET AT 80° F). THESE CIRCUITS ARE TO BE RUN THROUGH THE GE RELAY PANEL.
7. G.E. SOFTWIRE RELAY PANEL PROGRAMMING: A. SOFTWIRING LIGHTING GROUPS
a. THE SCM SHALL ALLOW ANY GROUP OF RELAYS WITHIN THE PANEL TO BE ASSOCIATED ("SOFTWIRED") TO A CHANNEL USING THE FOLLOWING PROCEDURE: • ...PRESS AND HOLD THE CHANNEL PUSH BUTTON FOR SEVERAL SECONDS. THE CHANNEL LED AND
THE LEDS FOR RELAYS CURRENTLY CONTROLLED BY THAT INPUT WILL BEGIN TO FLASH. • ...SELECT THE RELAYS TO BE CONTROLLED. THE LED FOR EACH RELAY "SOFTWIRED" TO THE
CHANNEL SELECTED WILL BE FLASHING ON/OFF. PRESS THE ASSOCIATED RELAY CONTROL BUTTON TO ADD/DELETE THAT RELAY TO/FROM GROUP.
• ...PRESS THE CHANNEL PUSH BUTTON AGAIN. THE LEDS WILL STOP FLASHING AND THE CHANNEL PUSH BUTTON AND ASSOCIATED SWITCH INPUTS WILL NOW CONTROL THE RELAYS SELECTED.
b. TURNING A CHANNEL ON/OFF WILL SEQUENCE ALL OF THE RELAYS WITHIN THAT GROUP ON/OFF INDIVIDUALLY.
B. CONTROLLING A SOFTWIRE GROUP a. EACH CHANNEL SHALL HAVE AN ASSOCIATED PUSH-BUTTON WITHIN THE PANEL TO TOGGLE THE
CHANNEL ON/OFF b. EACH CHANNEL SHALL ALSO HAVE TWO SEPARATE SWITCH OR DRY CONTACT INPUTS THAT WILL
ALLOW THE CHANNEL TO BE CONTROLLED REMOTELY. c. THE CHANNEL SHALL RESPOND TO THE LAST INPUT. d. THE UNIT SHALL ALLOW A "MASTER CHANNEL" TO BE CONFIGURED TO CONTROL SEVERAL OF THE
ABOVE CHANNELS BY SIMPLY INCLUDING ALL OF THE RELAYS OF THESE "SUB CHANNELS" WITHIN THE MASTER.
C. GROUP STATUS a. EACH CHANNEL PUSH-BUTTON SHALL INCLUDE A LED STATUS INDICATION. THE LED WILL BE ON
WHENEVER ALL OF THE RELAYS WITHIN THE CHANNEL GROUP ARE ON; AND SHALL GO OFF WHEN ALL OF THE RELAYS WITHIN THE GROUP GO OFF.
b. EACH CHANNEL SHALL ALSO HAVE AN ASSOCIATE DRY CONTACT CLOSURE OF PILOT CONTACT WHICH TRACKS THE LED OPERATION DESCRIBED ABOVE.
D. CONTROLLING AN INDIVIDUAL RELAY a. EACH RELAY SHALL HAVE AN ASSOCIATED CONTROL BUTTON WITH LED STATUS INDICATION
MOUNTED WITHIN THE LOW VOLTAGE SECTION OF THE PANEL.
FINISHED FLOOR
CP-1
MPS
NOTE: SUB-CONTRACTOR TO FURNISH AND INSTALL 3, 120V DEDICATED CONTROL CIRCUITS. BMS #1, BMS #2 & BMS #3. THESE CIRCUITS SHALL BE SOURCED FROM PANEL "CP".
NOVAR SYSTEM REQUIRES (1) 20A/3P CIRCUIT BREAKER AT MDP FOR PHASE MONITOR.PHONE LINE
FROM BUILDING PHONE SYSTEM.
TELEPHONE/SECURITY EQUIPMENT
SAME DEIDCATED CIRCUIT
ALARM SYSTEM ENCLOSURE
ALARM SYSTEM CONTROL PANEL
ALARM SYSTEM CONTROL PANEL
ALARM SYSTEM POWER SUPPLY
1
2 "
COUNTER SUPPORT (TO BE MOUNTED DIRECTLY NEXT TO THE WALL OR 30 INCHES FROM THE WALL.)
ACOUSTICAL CEILING TILE
TABLE/DESK COUNTER
110V, 24HR PLUG MOLD STRIP MOUNTED CENTRALLY ON WALL ABOVE DESKTOP, APPROX. 41" AFF ON BREAKER LOCK, DEDICATED CIRCUITS AS REQUIRED.
EQ EQ
MC-4 DPS
2 COND
NOTES: (1) ALL LOW VOLTAGE SIGNAL WIRING SHALL BE 20-GAUGE MINIMUM. THE MINIMUM INDUCTIVE LOAD (LOCK) POWER WIRE GAUGE SHALL BE DETERMINED PER THE SDC WIRE GAUGE CHART. ALL WIRING (SINGLE OR MULTI- CONDUCTOR) SHALL BE COLOR CODED WITHOUT SPLICES. A MINIMUM OF TWO SPARE CONDUCTORS IS RECOMMENDED. (2) SPECIFY VOLTAGE WHEN ORDERING PRODUCTS. VOLTAGE IS NOT SPECIFIED ON THIS WIRE DIAGRAM. BE SURE ALL PRODUCTS ARE VOLTAGE COMPATIBLE. (3) ALL WIRING MUST CONFORM TO NATIONAL, STATE AND LOCAL CODES. (4) ALWAYS CONSULT WITH THE AUTHORITY HAVING JURISDICTION (AHJ) BEFORE INSTALLATION. (5) WHERE REQUIRED BY CODE.
COMPONENTS:
QTY DESCRIPTION PART NUMBER MANUFACTURER 2 ELECTRIC STRIKE 45-4S U SDC 1 POWER SUPPLY W/DUAL INTERLOCK CIRCUIT BOARD 631RFA X UR2A SDC 2 MOMENTARY SPDT - PUSH BUTTON SWITCHES 15-2 X SPDT X MOM SDC 2 MAGNETIC DPS SWITCHES MC-4 SDC
METHOD OF OPERATION THE ABOVE LAYOUT IS IDENTIFIED AS A MANTRAP "B". BOTH OPENINGS HAVE MECHANICAL LOCKS THAT ARE LATCHED & UNLATCHED BY ELECTRIC STRIKES. ACCESS / EGRESS: ENTERING IS ACCOMPLISHED BY EITHER MECHANICAL KEY OR PUSH BUTTON CONTROL FROM INSIDE A CASH ROOM. EGRESS IS FREE AT ALL TIMES.
A5 A6 A7 A8 A9 A10 B5 B6 B7 B8 B9B10
STATION A OUTPUT
STATION B OUTPUT
Y
E1 E2 E3 E4 E5 E7 E8E6A1 A2 A3 A4 B4B2 B3B1 STATION A OUTPUT
STATION B OUTPUT
DIP SWITCH 1 2 3 4 5 6 7 8
ON
24 VDC OUTPUT
45-4S U ELECTRIC STRIKE
ITEM
NOTE: REFER TO TJX DRAWING C6 POWER PLAN FOR EXACT QUANTITY & LOCATION OF ALL DEDICATED / ISOLATED GROUND RECEPTACLES SHOWN IN THE DIAGRAM BELOW.
SINGLE QUE REGISTERS
QUADRUPLEX RECEPTACLE 15A, 125 VOLT, WITH ISOLATED GROUND.
PANEL "CP" 120/208V 1P 3W WITH NEUTRAL & ISOLATED GROUND GE 20 CIRCUIT WITH 2 POLE 30AMP MAIN C.B. BOLTON TYPE 20 IP - 20AMP C.B.
DOUBLE GANG BOX WITH BRUSHED ALUMINUM COVER PLATE T0 SUIT RECEPTACLE
DUPLEX RECEPTACLE 20A, 125 VOLT WITH ISOLATED GROUND
P.O.S. CASH REGISTER 120 VOLT WIRING
WIRING RUN THROUGH CONDUIT COORDINATE
WITH C6 SHEET
1/2" FLEXIBLE CONDUIT WITH APPROPRIATE WATERTIGHT
CONNECTOR
1/2" -3 NO. 10 TO POWER POLE J.B. (IF APPLICABLE)
SUSP. CEILING
SYSTEMS ROOM
NOT TO SCALE
3/4" -1 NO. 8 CONNECT DIRECTLY TO MAIN SERVICE GROUND
POWER PANEL
(IF APPLICABLE)
ALUM. POWER POLE WIREMOLD # NP600C ANCHOR AT CLG. & COUNTER TOP. (IF APPLICABLE)
REGISTERS
NOTES: 1. TJX SHALL BRING IN AN OUTSIDE
CONTRACTOR TO SUPPLY, RUN AND TERMINATE THE LOW VOLTAGE COMMUNICATION WIRING. THIS INCLUDES THE LOW VOLTAGE WIRING FOR REGISTERS POS AS WELL AS THE CABLE FOR THE TIME CLOCK, ACS AND MANAGERS OFFICE TO LAYAWAY CABLES.
2. CABLES TO BE RUN IN ONE PIECE FROM REGISTER TO REGISTER
3. ALL LOW VOLTAGE WIRING TO BE INSTALLED ABOVE HUNG CLG. AND SHALL BE KEPT A MINIMUM OF 5'-0" FROM FLUORESCENT LIGHTING FIXTURES
4. CONTRACTOR IS RESPONSIBLE FOR CONDUIT AND PULL STRINGS.
NOTES: 1. EXACT NUMBER AND FINAL LOCATIONS OF ALL ITEMS SHOWN
INCLUDING EXACT METHOD OF INSTALLING CONDUIT & WIRE SHALL BE DETERMINED IN THE FIELD WITH TJX REPRESENTATIVE.
2. ALL WIRING SHALL BE TYPE "THW" OR "THHN" COPPER RUN IN CONDUIT.
3. PROVIDE A SEPARATE NEUTRAL AND GROUND CONDUCTOR FOR EACH 120 VOLT CIRCUIT PROVIDED FROM PANEL "CP" PANEL "CP" SHALL BE USED TO SUPPLY ONLY REGISTER EQUIP.
4. ALL GROUND CONNECTORS SHALL BE ISOLATED (PURE- GROUND ONLY) AND SHALL NOT BE GROUNDED TO ANY METAL ENCLOLSURES.
5. THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS, RECEPTACLES, SWITCHES, ETC., TO IDENTIFY VOLTAGES AND FUNCTION.
6. PROVIDE RED NAMEPLATE STENCIL AS FOLLOWS: "FOR COMPUTER EQUIPMENT ONLY - NOT FOR GENERAL USE"
NOTES: CONVENIENCE OUTLETS AT SERVICE DESK SHALL NOT BE CONNECTED TO THE CP APNE.
P.O.S. A.C. WIRING TEST FOR INSULATED-ISOLATED GROUND
TO TEST DISCONNECT I.G. GROUND AT MAIN ENTRANCE AND CHECK ALL OUTLETS FROM:
GROUND TO BOX -------------NO CONTINUITY GROUND TO NEUTRAL ----- NO CONTINUITY- NO VOLTAGE GROUND TO HOT -----------NO VOLTATE
WITH I.G. GROUND HOOKED BACK UP AT MAIN PANEL I.G. GROUND TO BE TAGGED OR LABELED AT MAIN ENTRANCE.
GROUND TO BOX -------------NO CONTINUITY GROUND TO NEUTRAL ----- NO CONTINUITY- NO VOLTAGE GROUND TO HOT -----------120 VOLTS
REG 01
UPS UNIT SUPPLIED BY TJX COMPANIES INSTALLED BY GENERAL CONTRACTOR'S ELECTRICIAN.
*** ALL DELIVERY QUESTIONS SHOULD *** BE DIRECTED TO TJX SYSTEMS
IMPLEMENTATION AT 508-475-8105
UPS
CIRCUITS TO FEED, ISOLATED GROUNDED RECEPTACLES
AND ALL REGISTER LOCATIONS.
NOTES:
1. VERTIV RECOMMENDED WIRE SIZE, INCLUDING GROUND WIRE, @ 75° COPPER WIRE IS 10AWG (4mm). MAXIMUM WIRE ACCEPTED BY TERMINAL BLOCK IS 8AWG (6mm).
2. VERTIV RECOMMENDS INSTALLING A UL489 APPROVED BREAKER UPSTREAM OF UNIT.
3. THE INSTALLER MUST PROVIDE CIRCUIT BREAKER PROTECTION ACCORDING TO LOCAL CODES. THE UTILITY DISCONNECT SHOULD BE WITHIN SIGHT OF THE UPS OR HAVE AN APPROPRIATE LOCK OUT. MAINTAIN SERVICE SPACE AROUND THE UPS OR USE FLEXIBLE CONDUIT.
4. THE INSTALLER MUST PROVIDE OUTPUT DISTRIBUTION PANELS, CIRCUIT BREAKER PROTECTION, OR EMERGENCY DISCONNECTS ACCORDING TO LOCAL CODES.
5. OUTPUT CIRCUITS MUST NOT SHARE A COMMON.
6. CP PANEL WILL SERVICE ALL REGISTER POWER, BLADE SERVER, IDF, AND BMS POWER ONLY. NO OTHER CIRCUIT TO BE FED FROM CP.
A
30 AMP CP PANEL
**
Vertiv GXT5-5000MVRT4UXLN
UPS Installation Guidelines VERTIV CONTACT INFORMATION
VERTIV TECHNICAL SUPPORT PHONE: 800 - 222 - 5877 Option #1 Hardware Support
GENERAL INFORMATION: • GCs or Electrical Contractors are not required to purchase the UPS. • TJX provides all units from a third party location; DO NOT CALL
VERTIV WITH DELIVERY CONCERNS. • The units are a Vertiv GXT5-5000MVRT4UXLN tower UPS - 16.9”
(H) x 6.8” (W) x 26.1” (D) and weigh 132 pounds total. The units arrive in three separate boxes via FEDEX
• Wiring diagram is included on the TJX criteria, sheet C7. • Installation does NOT require Vertivto be onsite.
INSTALLATION: Electrical Contractor responsibilities: • Unpack/set/place the UPS, placement must conform to local and
national codes. • UPS ships in three boxes, UPS, Internal Battery pack and SNMP
card. Please refer to the UPS Manual, ships with the unit, for proper installation. Starts on Page 12.
• Terminate wiring at input and output of UPS. • Ensure distribution wiring, CP Panel, and disconnect are correctly
installed.
START UP Electrical Contractor responsibilities: • Unit must be turned on and taken out of BYPASS after installation is
complete. • Confirm the UPS is the only source feeding the CP Panel • Call Vertiv at the above number to troubleshoot any issues with
Start up • Provide support for Vertivif wiring issues arise during Start Up. • After UPS is Turned on and taken out of BYPASS without any
issues, the TJX PM must be notified that UPS installation is complete and the UPS is functional without issues.
A. FURNISH AND INSTALL A REAR DOOR ALARM CONTROL SYSTEM AT THE STOCK ROOM DOOR TO THE EXTERIOR (3'-0" X 6'-8"). PROVIDE 120 VOLT CIRCUIT (UNSWITCHED) AND A LOW VOLTAGE TRANSFORMER (24V/50 VA) U.L. APPROVED, ABOVE THE HEAD OF THE DOOR (WITHIN 10'-0"). ALARM SHALL BE ACTIVATED BY DOOR CONTACTORS WHEN DOOR IS OPEN POSITION AND SHALL PRODUCE A CONTINUOUS CHIME TONE.
B. DOOR ALARM SYSTEM SHALL BE WHEELOCK 38GV29 FROM GRAINGER INDUSTRIES MODEL #CH121092 WITH WEATHERPROOF PUSH BUTTON.
REAR DOOR ALARM CONTROL
BLACK: 120V
WHITE: NEUTRAL
NOTE: UNUSED LEAD MUST BE PROPERLY INSULATED WITH WIRENUT OR OTHER APPROVED METHOD.
CHARGER BOARD
BATTERY CONNECTOR
(SINGLE POLE)
INTR48-N48-GB00
CAT5 - CAN BUS
7 X AWG#18 - 6 ZONES CONTROLS USE ONE WIRE FOR EACH ZONE PLUS ONE COMMON
TO LOAD 120/277 V
THE SAME CIRCUIT THROUGHOUT CASH
REGISTER AREA. (TYP.)
QUAD I.G.
SINGLE DEDICATED OUTLET TO FACE OUTWARD AND BE MOUNTED BELOW THE DRAWER AND ABOVE THE ACCESS PANEL.
SINGLE DEDICATED OUTLET TO FACE OUTWARD AND BE MOUNTED BELOW THE DRAWER AND ABOVE THE ACCESS PANEL.
ACCESS PANEL WITH 1/4" COVER TYP. BOTH ENDS
RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON THE SAME CIRCUIT THROUGHOUT CASH REGISTER AREA. (TYP.)
RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON
THE SAME CIRCUIT THROUGHOUT CASH
REGISTER AREA. (TYP.)
ACCESS PANEL WITH 1/4" COVER TYP. BOTH ENDS
RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON THE SAME CIRCUIT THROUGHOUT CASH REGISTER AREA. (TYP.)
SINGLE DEDICATED OUTLET TO FACE OUTWARD AND BE MOUNTED BELOW THE DRAWER AND ABOVE THE ACCESS PANEL.
NOT TO SCALEC7 1
NOT TO SCALEC7 2 TYPICAL DETAIL @ L.P. OFFICE
NOT TO SCALEC7 4
NOT TO SCALEC7 5
NOT TO SCALEC7 6
NOT TO SCALE
SINGLE Q CHECK OUT STAND ELEVATION 'A' @ END CHECK OUT (TYPICAL)
Scale
Date
Store Number
Planned By
Deal Type
As indicated
C7 EL
03/11/21 KTL
JR/DEM
SINGLE Q CHECK OUT STAND ELEVATION 'A' @ CHECK OUT (TYPICAL)
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
SHOE TABLE
PALLET STAGING
HANGER RACK
6 5 4
4 STORAGE56 U
T.D. T.D. T.D.
120" AFF
53 " P
NL M
IR RO
R 53
" P NL
M IR
RO R
FOCAL WALL SAVING NEVER LOOKED SO GOOD
FO CA
L W
AL L
LO VE
T HE
L AB
EL A
ND T
HE P
RI CE
FO CA
L W
AL L
BR AN
D NA
M ES
F OR
L ES
S S S S S S S S S S
B B
P
NESTAFLEX
NESTAFLEX
8' -
10' 10' 10'
A
NOTE: REFER TO DOOR AND HARDWARE SCHEDULE ON DRAWING C2 FOR ALL ADA EXIT SIGN TYPES AND LOCATIONS.
1
2
3
4
5
EL EC
TR IC
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C8 EL
03/11/21 KTL
FIXTURE PLAN
NEWPORT, TN
JR/DEM
First Level Sales 84% 16,274.2 SF Supports 16% 3,182.4 SF
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
Sheets
C4 - INTERIOR ELEVATIONS
C8 - FIXTURE PLAN
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS SHOWN ON DRAWINGS AT THE JOB SITE, AND SHALL NOTIFY TJX IN WRITING OF ANY OMISSIONS, DISCREPANCIES, AND/OR CONFLICTS PRIOR TO SUBMITTAL OF BID OR BE RESPONSIBLE FOR THE SAME.
3. ALL WORK IS TO CONFORM TO THE REQUIREMENTS OF THE LOCAL AND STATE CODES. COORDINATE WITH THE OUTLINE SPECIFICATIONS.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL REQUIRED BUILDING PERMITS AND FOR INSURING THAT ALL WORK CONFORMS TO APPLICABLE BUILDING CODES.
5. WHERE COLOR AND DESIGN SELECTIONS ARE REQUIRED, THE CONTRACTOR SHALL SUBMIT SAMPLES TO TJX FOR APPROVAL AND SELECTION.
6. SHOP DRAWINGS SHALL BE SUBMITTED TO TJX FOR APPROVAL PRIOR TO FABRICATION OF ANY WORK SPECIFIED HEREIN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS AND PROPER INSTALLATION OF SAID WORK.
7. UNLESS OTHERWISE NOTED, IN THE TJX OUTLINE SPECIFICATIONS, NO SUBSTITUTIONS.
8. THE GENERAL CONTRACTOR SHALL HAVE DIRECT CONTROL AND MANAGEMENT OF ALL CONSTRUCTION OPERATORS AND BE RESPONSIBLE FOR THE SATISFACTORY OVERALL PERFORMANCE OF ALL HIS SUPPLIERS AND SUBCONTRACTORS AS WELL AS ALL ASSIGNED CONTRACTORS.
9. THE GENERAL CONTRACTOR IS TO RECEIVE, HANDLE, (STORE IF NECESSARY) AND BE RESPONSIBLE FOR ALL MATERIALS PROVIDED BY OTHERS. ALL MATERIALS SHALL BE ACCOUNTED FOR UPON RECEIPT. ANY MISSING OR DAMAGED PARTS SHALL BE REPORTED TO TJX IMMEDIATELY.
10. ALL WORK IS TO BE NEW EXCEPT WHERE INDICATED AS EXISTING.
11. ALL WOOD TO BE FIRE RETARDANT. RATINGS TO MEET REQUIREMENTS OF LOCAL, STATE, AND FEDERAL CODES.
12. GENERAL CONTRACTOR TO TURN OVER THE PROJECT IN COMPLETE OPERATING CONDITION.
13. THE CONTRACTOR IS RESPONSIBLE FOR TURNING OVER THE PREMISES IN A CLEAN CONDITION READY FOR TJX TO BEGIN OPERATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, CLEANING ALL WINDOWS (INSIDE AND OUT), MIRRORS, AND REMOVAL OF DUST FROM SURFACES AND FINAL VACUUMING OF CARPETS.
14. THE REFLECTED CEILING PLAN SHALL DICTATE LOCATION OF ALL EQUIPMENT AND LIGHTING. TJX PROJECT MANAGER IS TO BE INFORMED OF ALL CONFLICTS AND PROPOSED RESOLUTIONS. TJX PROJECT MANAGER HAS THE RIGHT TO FINAL APPROVAL OF PROPOSALS.
15. FLOORING CONTRACTORS SHALL BE RESPONSIBLE FOR PROPER PREPARATION AND INSTALLATION OF NEW FLOORING FINISHES. PREPARATION INCLUDES ADEQUATE CURING TIME FOR THE MASTIC TO REACH PROPER TACKINESS TO SET NEW FLOORING FINISHES. REFER TO TJX SPECIFICATION MANUAL FOR REQUIREMENTS FOR PREPARATION & TESTING.
16. FOR PURPOSES OF CLARITY, REFERENCES TO "C" REFERS TO THE CRITERIA DRAWINGS.
TJX GENERAL NOTES
PROVIDE CATWALK, INSTALL BEHIND SIGN FIELD. PROVIDE 30" X 30" LOCKABLE ACCESS TO INSIDE OF CANOPY.
ADD 3/4" EXTERIOR GRADE PLYWOOD BEHIND ENTIRE FACADE FOR INSTALLATION OF TJX SIGNS. SEE SECTION 1A OF SPECIFICATIONS.
SIZE OF SIGN TO BE DETERMINED BY LOCAL SIGN CODES AND COORDINATED WITH TJX BUILDING SIGN SPECIALIST.
Marshalls - Landlord Build-to-Suit (Outline Specifications #180) Rehab-to-Suit (Outline Specifications #1180)
ITEMS SUPPLIED BY MARSHALLS AND INSTALLED BY G.C.
1. Floor Mounted Carriage Bumper 2. Wall Bumper 3. Cup Dispenser 4. Sanitary Napkin Dispenser 5. Sanitary Napkin Disposal 6. Toilet Paper Dispenser 7. Deodorant Holder 8. Soap Dispenser 9. Toilet Seat Cover Dispenser 10. Freestanding Restroom Trash Receptacle 11. Power Poles 12. Dressing Room Lighted Mirrors 13. LP Bench 14. Permanent Chrome Rail 15. Baby Changing Table
EXT EXTERIOR REINF REINFORCED
GARMENT HANGER
GYPSUM BOARD
MANUFACTURER
MISCELLANEOUS
NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE NATURAL FINISHED WOOD
OUTSIDE DIMENSION
ABOVE FINISHED FLOOR
ELECTRIC WATER COOLER
CR.PL.
CONT
ELECTRIC
CONTINUOUS
AL
CEILING HEIGHT CASH REGISTER
ABBREVIATIONS
REVISION NUMBER
FINISH NUMBER
DOOR NUMBER
ROOM NUMBER
ELEVATION MARK
COLUMN SIGN TO BE 8'-0" MINIMUM A.F.F.
Scale
Date
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C1 EL
03/11/21 KTL
TITLE SHEET
NEWPORT, TN
JR/DEM
DRAWING INDEX
C1 TITLE SHEET C2 CONSTRUCTION PLAN C3 WALL SECTIONS & MISC. DETAILS C4 INTERIOR ELEVATIONS C5 REFLECTED CEILING PLAN C6 POWER PLAN C7 P.O.S., REGISTER, & ELEC DTLS. C8 FIXTURE PLAN
MARSHALLS STOREFRONT FINISH SCHEDULE FINISH
NO. MATERIAL MANUFACTURER SPECIFICATION 137 EIFS DRYVIT #310 "CHINA WHITE" 138 PAINT BENJAMIN MOORE CLOUD WHITE #967. PAINT TO MATCH CHINA WHITE DRYVIT. (EGGSHELL) 305 PAINT BENJAMIN MOORE #2061-20 "CHAMPION COBALT" (EGGSHELL) 325 VINYL DGS RETAIL INC. MARSHALLS - 3M DARK BLUE 326 SPANDREL GLASS SOLAR SEAL
COMPANY 1" CLEAR/CLEAR WITH SPANDREL. 1/4" CLEAR WITH 6-0025 HARMONY BLUE (2). 1/2" AIR SPACER. 1/4" CLEAR
327 EIFS DRYVIT #449 "BUCKSKIN" (SANDBLAST) 328 PAINT BENJAMIN MOORE #965 "TEMPORAL SPIRIT". PAINT TO MATCH "BUCKSKIN" DRYVIT.
(EGGSHELL) 329 EIFS DRYVIT #112 "SANDLEWOOD BEIGE" (SANDBLAST) 330 EIFS DRYVIT #578 "MIDNIGHT BLUE" (SANDBLAST) 338 LAMINATED PANEL SUNBRELLA MARINE BLUE
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
Mantrap Equipment Cushman & Wakefield 128 N. 1st Street Colwich, KS 67030 316-600-0971 Siobhan Panias ([email protected])
General light Fixtures, Plugmold, Power Poles, Safety Switches, GE Lighting control panel
(8 Week Lead Time) NESCO 40 Hudson Road
Canton, MA 02021 800-244-6980 [email protected]
16 - ELECTRICAL
HVAC Controls (4 Week Lead Time) Novar / Honeywell Multisite 6060 Rockside Woods Blvd., Suite 400, Independence, OH. 44131
216-682-1600 800-348-1235 [email protected]
HVAC Equipment/ Roof Exhaust Fans, Circulator Fans... York/Johnson Controls 5005 York Drive... 405-419-6447... Saul Diaz: [email protected]...
15 - MECHANICAL
Vertical Lifts/Scissor Lifts (12 Week Lead Time) Conveyors ( 8 week lead time)
Deluxe Systems, Division of W.T. Hight Co.
42 Winter Steet, Pembroke, MA. 02359 508-588-4410 [email protected]
Elevators & Escalators (West Coast Only) Mitsubishi Electric & Electronics 5665 Plaza Drive Cypress, CA 90630 714-220-4700
Elevators & Escalators ThyssenKrupp Elevator 114 Town Park Drive, Suite 300 Kennesaw, GA 30144 800-824-9666
Elevators & Escalators (16 Week Lead Time) Otis Elevator Company 61 Fourth Avenue Needham, MA 02494
781-433-8600 781-433-7700
Elevators & Escalators (16 Week Lead Time) Kone 1 Kone Court Moline, IL 61265 800-334-9556
Elevators & Escalators (16 Week Lead Time) Schindler Elevator Corporation 20 Whippany Road Morristown, NJ 07960 800-225-3123
14-CONVEYING SYSTEMS Hand Dryers EXCEL (Xlerator) 888-994-4128 [email protected]
Bailers, Compactor Security Door, Compactor Chute, & Compactor Machine PTR Baler & Compactor Co. 2207 East Ontario Street
Philadelphia, PA 19134 215-537-2211 (Sales) 215-533-5100 (Parts)
Patricia Dougherty: [email protected] Parts: [email protected]
Dock Seals and Bumpers Frommelt Dock & Door 35R Holden Street Winchester, MA 01890 800-243-3302
11 - EQUIPMENT
Toilet Partitions ASI Global Partitions 2171 Liberty Hill Road Eastanolles, GA 30538 706-827-2700 Cathy Bennet: [email protected]
General: [email protected]
10 - SPECIALTIES
Combo Only HomeGoods Side Flooring Parterre Flooring System 500 Research Drive Wilmington, MA 01887
978-203-5400 ext. 401 978-203-5400 ext. 217
Order: Jeff Leger: [email protected] Sales: Chris Easler: [email protected]
Faux Brick (6 to 8 Week lead Time) Symmetry International 55 Industrial Circle Lincoln, RI 02865 401-5781201 Juli Lancia: [email protected]
Processing Transition Strip MAPEI Corp. 1144 East Newport Center Dr. Deerfield Beach, FL 33442 800-992-6273 [email protected]
Vinyl Floor Planking (4 Week Lead Time) Mannington / Amtico International, Inc. 6480 Roswell Road Atlanta, GA 30328 800-321-2519 ext. 6412 Joyce Holbert: [email protected]
General: [email protected]
Wallcovering (4 Week Lead Time) MDC Wall Covering 1200 Arthur Avenue Elk Grove, IL 60007 800-486-9800 [email protected]
[email protected]
Restroom Wall (89 Smoke Grey) & Floor Grout (#60 Dusty Grey) Laticrete One Laticrete Park North
Bethany, CT 06524 1-800-243-4788 x1219 [email protected]
Restroom Wall & Floor Tile Daltile 1300 East Plano Parkway Plano, TX 75074
TP: 877-556-5728 800-486-5724
Tim Phoenix: [email protected] General: [email protected]
Vestibule Mat The Matworks 11900 Old Baltimore Pike Beltsville, MD 20705
MC: 301-832-8703 General: 800-523-5179
Vinyl Composition Tile (VCT) Armstrong Flooring Inc. Commercial National Accounts 877-212-8511 [email protected]
Acoustical Ceiling System Armstrong World Industries 2500 Industrial Drive Lancaster, PA 17603 800-442-4212 [email protected]
09 - FINISHES
Coiling Overhead Service Door Metro Door, Inc. 821 Industrial Drive, Lewisburg, TN. 37091
833-969-3667 [email protected]
Gabe Cross - Ext 743 Amanda Prosser - Ext 774
Doors, Door Frames, and Door Hardware DH Pace National Accounts 1901 E 119th St Olathe, KS 66061 417-831-5585 x 5622 Paula Jamison: [email protected] Bid requests: [email protected]
Jimmy Guard Don-Jo Mfg., Inc. 70 Pratt Junction Road P.O. Box 929 Sterling, MA 01564 978-422-3377
Impact Doors Eliason Easy Swing Door Division 9229 Shaver Road Kalamazoo, MI 49003 800-543-4455 [email protected] - add TJX to subject
line
Sliding Door Operators (8 Week Lead Time) Stanley Automatic Doors 65 Scott Swamp Road... RD: 860-679-6431... Ryan Driscoll: [email protected]
08 - DOORS & GLASS
Combo Only HomeGoods Side Light Valance/Molding/Focal Wall Molding/Focal Wall
Kit/Restroom Mirror Molding (4 Week Lead Time) DGS Retail LLC 60 Maple Street
Mansfield, MA 02048 508-337-2990 [email protected]
Slatwall Column Corner Guard Wind Mill Woodwork, Inc. 200 Balsam Road Sheboygan Fall, WI 53085 800-548-7528 (Sales)
Corner Guards ATR Sales, Inc. 41 Talbot Road Northboro, MA 01532 (508) 393-8529
Outrigger ( 6 week lead time) Light Valance Brackets (4 week lead time) LOZIER Main: 800-228-9882,
Direct: 402-457-8218 Terry Marchand, Account Services
[email protected] [email protected]
Light Valance/ Molding & Focal Wall Molding... DGS Retail LLC 60 Maple Street... 508-337-2990 [email protected]
Slatwall System, Beadboard Paneling (6 Week Lead Time) DGS Retail 1201 Kirk Street
Elk Grove Village, IL 60007 (847) 350-3020 Erin Patterson [email protected]
06 - CARPENTRY
Description Company Name Address Contact Phone Contact Email
**LONG LEAD TIME POSSIBLE** NOTE: WHEN CONTACTING VENDORS, PLEASE INDICATE THAT YOU ARE WORKING ON A TJX PROJECT TO ENSURE NATIONAL ACCOUNT PRICING/SUPPLY.
APPROVED MARSHALLS VENDOR LIST
32' - 4" FIX. STOR. SYS.
PALLET STAGING
END
FOCAL WALL SAVING NEVER LOOKED SO GOOD
FO CA
L W
AL L
LO VE
T HE
L AB
EL A
ND T
HE P
RI CE
FO CA
L W
AL L
BR AN
D NA
M ES
F OR
L ES
E. W
8' -
106
108
STORE FIXTURES BY OTHERS
THREE (3) 2 1/2" CONDUITS TO BE CONCEALED IN FLOOR & WALL ON SALES AREA SIDE.
CONDUIT TERMINATION POINT. LOCATED UNDER CASH REGISTER COUNTER.
ALL V.C.T. TO BE INSTALLED WITH 1/4 TURN PATTERN
A MINIMUM OF (2) TWO STOREFRONT WINDOWS SHALL HAVE A MINIMUM CLEAR LITE DIMENSION OF 4'-0" WIDE X 6'-0" HIGH
ALL GLASS INCLUDING GLASS DOORS TO BE PROTECTED BY A HORIZONTAL MULLION ON BOTH SIDES @2'-4" A.F.F.
SEE NOTE ON INTERIOR ELEVATIONS SHT. FOR GLAZING REQUIREMENTS @ VESTIBULE.
UPPER GLAZING @ DOOR TRANSOMS ON SALES SIDE SHALL RETAIN A 1" GAP BETWEEN GLAZING AND VERTICAL FRAMES TO ELIMINATE NEGATIVE AIR PRESSURE IN VESTIBULE. GLASS TO BE RADIUSED AND GROUND SMOOTH ON BOTH SIDES.
ALL TOILET FIXTURES, HARDWARE, ACCESSORIES, MIRRORS, AND FINISHES TO BE SUPPLIED BY G.C. AS PER TENANT SPECS. TOILET PAPER HOLDERS AND ALL DISPENSERS ARE SUPPLIED BY TENANT AND ISTALLED BY G.C. G.C. IS RESPONSIBLE TO PROVIDE ALL BLOCKING FOR TOILET ROOM ACCESSORY INSTALLATION. PLEASE COORDINATE WITH SHEET C4 OF THE CRITERIA PLANS AND THE TJX PROJECT MANAGER FOR EXACT LOCATIONS.
NOTE FOR COMPACTOR: IF EXTERIOR GRADE IS MORE THAN 12 INCHES BELOW THE INTERIOR FINISHED FLOOR, THE BOTTOM OF THE SECURITY DOOR SHOULD BE AT 44" A.F.F. IF LESS THAN 12 INCHES BELOW, THE SECURITY DOOR SHOULD BE AT 54" A.F.F. COMPACTOR IS 50" HIGH.
8' X8
' C O
IL IN
G S
ER VI
C E
D O
O R
EA C
H J
AM B
INSTALL 3 1/2" SOUND INSULATION IN ALL PARTITIONS & CLG. IN MGR. OFFICE
SE E
D ET
AI L
7/ C
4 FO
ES .
LIGHTS TO BE MOUNTED AT 12'-0" A.F.F. MECHANICAL, ELECTRICAL, AND PLUMBING TO BE MOUNTED WITH ADEQUATE CLEARANCE BETWEEN TOP OF LIGHTING FIXTURES AND ROOF DECK.
10' X 40' COMPACTOR PAD
VESTIBULE 1
PROCESSING ROOM
G.C. IS RESPONSIBLE FOR PROVIDING AND INSTALLING V.C.B. ON ALL CHECKOUTS, LAYAWAY PICK-UP COUNTER, LOUNGE KITCHENETTE, AND INSIDE/OUTSIDE JEWELRY COUNTER (IF APPLICABLE).
NOTE: DIRECTION OF ARROWHEADS INDICATES DIRECTION OF FLOORING
FOR RELEASE LATCHES MINIMUM CLEARANCE REQ.
19" CLEAR FROM ANY OBSTRUCTIONS 34" AFF TO OPERATION POINT
TYP. COL. COVER UNLESS NOTED OTHERWISE AT SALES FLOOR
FLOOR DRAIN
VW C
T ER
M IN
AT IO
N P
O IN
BENJAMIN MOORE INSL-X TP2220 LATEX TRAFIC PAINT, COLOR-BLACK.
W H
ER E
R EQ
U IR
ED B
Y LO
C AL
C O
D E,
M ET
R O
D O
O R
28' - 10" 24' - 1" 23' - 11" 24' - 1" 28' - 10"
15 4'
8' - 6" 20' - 9" 5' - 0" 16' - 5" 10' - 0"
17 ' -
3 "
6' -
5' - 11 1/2"
/2 "
19' - 11" 3' - 10" 15' - 7 1/2" 25' - 2 1/2" 17' - 1 1/2" 15' - 7 1/2" 3' - 1 1/2"4' - 5 1/2" 10' - 10"
WOMEN'S D.R.
4' - 0"
4' - 0"
1" 3'
3' - 1 1/2"
HOLD 22' - 9"
HOLD 7' - 0"
HOLD 56' - 0"
H O
LD 26
1 C3
4 C3
4 C3
4 C3
4 C3
LOGO
* OPENING SIZE IS THE ACTUAL SIZE OF THE DOOR UNLESS OTHERWISE NOTED. *INTERIOR DOORS ARE TO MEET ADA REQUIREMENTS AND MUST HAVE 18” CLEAR ON THE PULL/STRIKE SIDE OF THE DOORS.
REFER TO FIXTURE INSTALLATION MANUAL FOR 'ADA' EXIT SIGNS AS NOTED ON DOOR & HARDWARE SCHEDULE.
10 ' -
0 "
KICK PLATE AS REQUIRED
HOLLOW METAL HOLLOW METAL ALUMINUM ALLOY RECEIVING ROLL-UP DOOR (SEE DOOR
SCHEDULE FOR SIZING).
HEAD AND JAMB
WIRE MESH (SEE DTL.)
FOR FURTHER DETAIL ON WALL SYSTEM INSTALLATION, REFER TO THE MANUFACTURER INSTALLATION INSTRUCTIONS.
CORNER BEAD (TYP.) METAL KNOCK DOWN FRAME (TYP.)
METAL KNOCK DOWN FRAME
2 '-
0 "
X C3
X C3
NOTE:
1. INSTALL 3" WIDE EPOXY THRESHOLD UTILIZING "MAPEI - PLANIBOND EBA" WHICH IS A TWO COMPONENT BONDING AGENT AND PRIMER. INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED INSTALLATION METHODS. SYSTEM FORMALLY KNOW AS "EPO / BOND30".
2. CENTER REDUCER STRIP TO DOOR FRAME OR WHERE INDICATED ON PLAN.
CONCRETE SLAB SALES FLOOR FINISH.
REFER TO C-1
SINGLE DRAWER
BASE UNITS
ADJUSTABLE SHELF
59" A.F.F.
15" DEEP SHELF WITH 2" RADIUS EXPOSED CORNERS.
CABINETS: AS MANUFACTURED BY "HAMPTON BAY (OR EQUAL) 30" W × 27" H X 22" D CLEAR KNEE SPACE AT SINK (3) 18" W × 24" D. BASE CABINETS WITH ADJUSTABLE SHELVES - CUT TOE SPACE AS REQUIRED FOR 34" ADA HEIGHT TOP OF SINK RIM. (1) 18" H × 36" W × 12" D. WALL CAB. (2) HAMPTON BAY DISH WASHER END PANEL.
COLOR: MANUFACTURER'S SATIN WHITE FINISH
FURNISH MANUFACTURER'S STANDARD 4" DRAW AND DOOR PULLS
COORDINATE LOCATION OF PAPER TOWEL AND SOAP DISPENSERS WITH TJX PM.
ELECTRICAL REQUIREMENTS AS SHOWN
ONE "ADA" COMPLIANT DROP IN STAINLESS STEEL SINK, AND "ADA" COMPLIANT FAUCET. PAINT SINK CUT OUT EDGES WITH OIL BASED PAINT.
AMERICAN WITH DISABILITIES ACT (ADA) REQUIREMENTS: CONTRACTOR SHALL ORDER "HANDICAP CABINETS" COMPLYING WITH ADA REQUIREMENTS AS FOLLOWS: 34" IS MAX. HEIGHT PERMITTED TO TOP OF SINK RIM OR COUNTER. PROVIDE SINK THAT DOES NOT EXCEED MAXIMUM DEPTH OF 6 1/2".
PROVIDE SLANTED FRONT PANEL AT SINK TO CONCEAL PLUMBING. COLOR TO MATCH CABINETS.
36"
5
4 "
HAMTON BAY. 30" × 4" FLAT FRONT PANEL ATTACHED AS REQUIRED
1A C4
1A C4
1
8 "
CUSTOM OPEN BOX CABINET 36"W × 24"H × 12"D. COLOR TO MATCH CABINETS.
2
5 "
4 "
HAMPTON BAY DISH WASHER END PANELHAMPTON BAY DISH WASHER END PANEL.
MODIFY AS REQUIRED.
6" VINYL COVE BASE
GALVANIZED ALUMINUM SILL COVER W/ 2" DOWNTURN LEG COLOR TO
MATCH WINDOW FRAME
NEW WALL EXTEND WALL CONSTRUCTION, INCLUDING PLYWOOD WHERE APPLICABLE TO UNDERSIDE OF DECK (BOTH SIDES). SEE CONSTRUCTION PLAN FOR WALL TYPE.
LEGEND
HARDWARE TO BE FINISHED AS FOLLOWS: 1.PROVIDE BURGLAR PROOF HINGES N.R.P. WHERE EXPOSED TO OUTSIDE OR COMMON AREAS. 2. PROVIDE DOOR STOP ON ALL DOORS (INCLUDING SAFE DOOR), WHERE THEY ARE LIABLE TO DAMAGE THE WALL OR ADJACENT FIXTURE. 3.PAINT ALL METAL DOORS. REFER TO INTERIOR ELEVATIONS SHEET. 4.ALUMINUM ALLOY DOUBLE ACTION DOOR (ONE OR TWO DOORS) TO BE "EASY SWING" TYPE. 5.ALL LOCKS AND LOCKING DEVICES ARE TO BE BEST CONSTRUCTION CORES 6.G.C. TO INSTALL PERMANENT CORES SUPPLIED BY TENANT. 7.PROVIDE KAWNEER STYLE F-2 PUSH-PULL ON ALUMINUM AND GLASS DOORS. DO NOT INSTALL PULL ON DOORS NO. 3 (VEST. SIDE) 8.DOOR HOLDERS TO BE INSTALLED ON THE KICK-PLATE SIDE OF DOOR, EXCEPT AT TOILET ROOMS. 9.FOR EXTERIOR DOORS, PULL TO BE INSTALLED ON INSIDE OF DOOR, ABOVE DETEX. 10. THRESHOLD FOR VESTIBULE ENTRANCE AND EXIT DOORS BY ZERO INTERNATIONAL #1675A, ALUMINUM UTILITY SADDLE, 4"x1/2". 11. THRESHOLDS FOR EXTERIOR HOLLOW METAL DOORS BY ZERO INTERNATIONAL #654A, ALUMINUM UTILITY SADDLE, 4"x1/2"
Scale
Date
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C2 EL
03/11/21 KTL
CONSTRUCTION PLAN
NEWPORT, TN
JR/DEM
NO. ROOM
AC O
U ST
IC AL
T IL
ET ile
G YP
SU M
B O
AR D
N O
F IN
IS H
ED C
EI LI
N G
C EI
LI N
G H
EI G
H T
1 VESTIBULE 115 10' - 2" SECURE WITH HURRICANE CLIPS. PAINT ALL EXPOSED WALLS (305)
2 SALES Varies 341 Varies Varies SEE CONSTRUCTION PLAN AND INTERIOR ELEVATIONS FOR FINISHES.
3 PROCESSING ROOM 112 341 SEAL YELLOW SAFETY WALKWAY
4 DRESSING ROOM ENTRANCE 311 341 Varies 9' - 0" SEE SHEET C4 FOR FINISHES. 5 MEN'S DRESSING ROOM 312 341 334 9' - 0" SEE SHEET C4 FOR FINISHES. 6 WOMEN'S ADA DRESSING
ROOM 311 341 335 9' - 0"
7 MEN'S ADA DRESSING ROOM 312 341 334 9' - 0" 8 WOMEN'S DRESSING ROOM 311 341 335 9' - 0" SEE SHEET C4 FOR FINISHES. 9 CASH OFFICE 308 341 303 9' - 0" 10 HALL AT CASH 308 341 303 9' - 0" 11 L.P. OFFICE 308 341 303 9' - 0" 12 SYSTEMS ROOM 112 341 13 LOUNGE 106 /
108 342 116 /
DESIGNATION. FINISH NO. 407 MOUNTED @ 24" A.F.F.
14 JANITOR'S CLOSET 308 341 303 / 323
9' - 0"
308 341 303 9' - 0"
16 MANAGER'S OFFICE 308 341 303 9' - 0" 17 HALL AT LOUNGE 308 341 303 9' - 0" 18 MEN'S TOILET 340 341 303 /
339 9' - 0" PAINT CEILING #113. TILE ON
ALL WALLS TO 39 7/8" A.F.F. 19 WOMEN'S TOILET 340 341 303 /
339 9' - 0" PAINT CEILING #113. TILE ON
ALL WALLS TO 39 7/8" A.F.F. 20 LEARNING CENTER 308 341 303 9' - 0" SEE FIXTURE INSTALLATION
MANUAL FOR GRAPHICS PLACEMENT
NOT TO SCALEC2 6
DOOR & HARDWARE SCHEDULE DOOR LOCATION NO.
OPENING / DOOR SIZE HEAD & JAMB TYPE TYPE KICKPLATE HARDWARE REMARKSWIDTH HEIGHT
VESTIBULE 1 14' - 0" 7' - 8" --- --- --- HJ BIPARTING DURAGLIDE 3000. THRESHOLD & MOTOR HEADER INCLUDED, EXTERIOR & INTERIOR TRANSOM SUPPLIED AND INSTALLED BY GC. (SELF SUPPORTING TRANSOM REQUIRED).
VESTIBULE 2 14' - 0" 7' - 8" --- --- --- HJ BIPARTING DURAGLIDE 3000. THRESHOLD & MOTOR HEADER INCLUDED, EXTERIOR & INTERIOR TRANSOM SUPPLIED AND INSTALLED BY GC. (SELF SUPPORTING TRANSOM REQUIRED).
LOADING DOOR 3 8' - 0" 10' - 0" --- 4 --- OO SEE SPECS AT PLAN LOCATION THIS SHEET. (2) LOCKS PER DOOR.
PROCESSING ROOM 4 6' - 0" 7' - 0" C 3 1 SIDE --- FLAT FRAME BY GC, ELIASON EASY SWING DOORS (72"X84") #SCP-1 "ALUMINUM", BUMPERS EACH SIDE, EXIT SIGN, TYPE "B".
HALL AT LOUNGE 5 4' - 0" 7' - 0" A --- --- --- DRESSING ROOM ENTRANCE 6 18' - 0" 8' - 6" A --- --- --- USE CLEAR PLASTIC CORNER GUARDS. WOMEN'S ADA DRESSING ROOM 7 3' - 0" 7' - 0" B 2 1 SIDE AGW1V2 MOUNT DOOR STOP AS REQ'D. SO DOOR DOES NOT
HIT MIRROR. DOOR TO HAVE 1" UNDERCUT.
MEN'S ADA DRESSING ROOM 8 3' - 0" 7' - 0" B 2 1 SIDE AGW1V2 MOUNT DOOR STOP AS REQ'D. SO DOOR DOES NOT HIT MIRROR. DOOR TO HAVE 1" UNDERCUT.
PROCESSING ROOM COMPACTOR SECURITY DOOR
9 4' - 0" 4' - 0" --- --- --- O SLIDER COMPACTOR SECURITY DOOR. GC PURCHASE FROM PTR, GC INSTALLS, SEE PLAN FOR DOOR TYPE.
L.P. OFFICE 10 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV HALL AT CASH 11 3' - 0" 7' - 0" B 2 --- ACGL ELECTRIC STRIKE BY SDC. DOOR FRAME TO COME
READY FOR SDC 45 4S U, 4" FACE PLATE. SEE DETAIL ON DRAWING C7. DOOR TO HAVE 1" UNDERCUT.
CASH OFFICE 12 3' - 0" 7' - 0" B 1 1 SIDE ACGLSZ ELECTRIC STRIKE BY SDC. DOOR FRAME TO COME READY FOR SDC 45 4S U, 4" FACE PLATE. SEE DETAIL
ON DRAWING C7 SYSTEMS ROOM 13 3' - 0" 7' - 0" B 2 --- A1CWV USE TAMPER-PROOF HINGES. JANITOR'S CLOSET 14 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV LEARNING CENTER 15 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV EMERGENCY EXIT 16 3' - 0" 7' - 0" B 1 1 SIDE AGPRTY EXIT SIGN TYPE "B" EMERGENCY EXIT 17 3' - 0" 7' - 0" B 1 1 SIDE AGPRTY EXIT SIGN TYPE "B" EXIT MAN DOOR 18 3' - 0" 7' - 0" B 1 --- A1GPRSTY EXIT SIGN TYPE "B" MEN'S TOILET 19 3' - 0" 7' - 0" B 2 1 SIDE ACEFGV DOOR TO HAVE 1" UNDERCUT. WOMEN'S TOILET 20 3' - 0" 7' - 0" B 2 1 SIDE ACEFGV DOOR TO HAVE 1" UNDERCUT. ASSISTANT MANAGER'S OFFICE 21 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV LOUNGE 22 3' - 0" 7' - 0" B 2 1 SIDE ACGUV MOUNT DOOR HOLDER AS REQ'D. SO AS NOT TO BE A
TRIPPING HAZARD. MANAGER'S OFFICE 23 3' - 0" 7' - 0" B 1 1 SIDE ACGLSV
HVAC AREA ANALYSIS
Dressing Room 1,056.3 SF Processing Room 1,269.3 SF Sales 15,045.1 SF Support 1,566.3 SF Systems Room 117.9 SF
DOOR HARDWARE NO HARDWARE DESCRIPTION HARDWARE MANUFACTURER & MODEL A HINGES STANLEY FBB179, 4½" × 4½" (1½ PAIR), US26D A1 HINGES STANLEY FBB191, 4½" × 4½" NRP (1½" PAIR), US32D B DOUBLE ACTING HINGE BOMMER #3029, 6 × 4½" 652 (1½" PAIR), US26D C CLOSER LCN "SMOOTHEE" #4031 X WMS AL (ON HINGE SIDE) D OPEN E PUSH PLATE ROCKWOOD 70C, 4" × 16" PUSH PLATE, US32D F PULL PLATE ROCKWOOD 110 × 70C, PULL PLATE 4" × 16", US32D G KICK PLATE ROCKWOOD K1050, 8" × DOOR WIDTH (MINUS 2"), US32D H MORTISE CYLINDER BEST #1E-7-6-C181-RP1 X L/C, 626 H1 RIM CYLINDER BEST #12E-7-2-S2-RP X L/C, 626 J TURNKNOB BEST #1EA-6-A4-C413-RP2, 626 K DUMMY CYLINDER BEST # 1E-04, 626 L STOREROOM LEVER LOCKSET BEST #9K3-7-D-15-D-S3 X L/C, 626 L1 CLASSROOM LEVER LATCHSET BEST #9K3-7-R-15-D-S3 X L/C, 626 M PASSAGE LEVER LATCHSET BEST #9K3-O-N-15-D-S3, 626 N CLASSROOM TUBULAR DEAD
LOCK BEST #8T3-7-S-8TD3B-STK, 626 (FOR EXTERIOR DOOR W/CUT OUT)
O PADLOCK BEST #21-B-7-22-L X L/C, 626 P ALARM EXIT LOCK-SGL DETEX ECL-230D-PH ECL-1595, GRAY P1 ALARM EXIT LOCK UL-SGL DETEX ECL-600, GRAY (USE WITH FIRE RATED DOORS) P2 ALARM EXIT LOCK UL-SGL-O\A DETEX LEVER TRIM ECL-620, GRAY Q ALARM EXIT LOCK-DBL DOORS DETEX ECL-230D-PH ECL-1595 VRA-143B 84, GRAY R CHAIN CRASH STOP IVES #CS115 × 25½, US26D
NATIONAL GUARD MODEL: 16A (DRIP CAP) S DOOR SAFETY VIEWER ROCKWOOD #622 CRM 190 DEGREE T WEATHERSTRIPPING (INCLUDES) NATIONAL GUARD C627A (BRUSH SEAL),
NATIONAL GUARD MODEL 16A (DRIP CAP), NATIONAL GUARD 122NA (HEAD & JAMB GASKETING), NATIONAL GUARD 424E (THRESHOLD)
U PUSH BUTTON LOCKSET ALARM LOCK SL2700IC-26D, TRILOGY T2 (KEY OVERRIDE) V FLOOR STOP & DOOR HOLDER ROCKWOOD #491, US26D V1 PLUNGER DOOR HOLDER ROCKWOOD #459, US26D V2 FLOOR MOUNTED DOOR STOP ROCKWOOD #441CU, US26D V3 WALL MOUNTED DOOR STOP ROCKWOOD - DH PACE TO SELECT W STOREROOM LEVER LOCKSET
(TACTILE) BEST #9K3-7-D-15-D-S3 X L/C TL (B), 626
W1 PRIVACY LEVER SET BEST #7KC3-0-L-15-D-S3, 626 X FLUSH BOLT ROCKWOOD 55 US26D Y PULL ROCKWOOD 131, US26D Z JIMMY GUARD DON-JO MFG, INC. #ILP-206-SL
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
TOP OF BOX WALL 7'-11" A.F.F. (FINISH WITH 5/8" GYP. BD.
TOP) PAINT #303.
22" MIN. FROM FACE OF SLATWALL (TYP.) V.I.F.
GYPSUM BOARD BOX CORNER W/ 5/8" GYP. BD.
ON METAL STUDS.
303
341341
5/8" GYPSUM BOARD.
E.T.M.
2
1 MIRROR 4 SIDES OF COLUMN FROM 2' - 4½" (TOP OF BUMPER) TO 8' - 0". UNLESS NOTED OTHERWISESIZE VARIES W/ COLUMN SIZE. (12" MINIMUM WIDTH, TYP. )
ELECTRICAL OUTLET @
18" A.F.F.
6 ½
NOTES:
1. REFER TO SIZE TABLE TO DETERMINE DIMENSIONS. WIDTH AND DEPTH ARE INSIDE DIMENSIONS OF THE CAGE STRUCTURE.
2. CONSTRUCT USING 2" x 4" WOOD STUDS COVERED ALL SIDES EXCEPT WHERE AGAINST WALL WITH 14 GAUGE, 1" X 2" WIRE MESH. SECURE TO WALL. PROVIDE 1/2" PLYWOOD TOP. PROVIDE FIELD BUILT DOORS FULL HEIGHT AND ALLOWING ACCESS TO FULL WIDTH OF SHELVES. CONSTRUCT DOORS OF 2" x 4" STUDS AND HARDWARE CLOTH WITH CROSS BRACING, HINGES, AND LOCK HASPS. SHELVES BY OTHERS.
3. HEIGHT OF LOCKING STORAGE CAGE SHALL BE DETERMINED BY SIZE TABLE.
4. GENERAL CONTRACTOR SHALL INCLUDE SECURITY CAGE IN BASE BID.
LOCK HASPS
TOP OF SHELVING UNIT
8'
DEPTH WIDTH HEIGHT
SECURITY CAGE (10')
CAGE TYPE
O VE
R AL
L H
EI G
H T
SE E
SI ZE
T AB
DIGI UNIT
DIGI UNIT
MULLION
GLASS
GLASS
2'
- 4
CORE FLOOR & SET SLEEVES AS PER INSTALLATION INSTRUCTIONS
LENGTH: USE LONGEST STANDARD LENGTHS POSSIBLE TO FIT PLAN. PROVIDE CUSTOM LENGTH SECTIONS WHERE REQUIRED.
6 "
FLOORING SPEC
ARMSTRONG SAFTEY ZONE SLIP RETARDENT
#57004 SLATE BLACK
FIN. FL. FIN. FL.
DIRECT RING DOWN CONNECTOR
WALL MOUNTED OR CEILING HUNG LOCATION SIGN. (SEE SIGN PACKAGE BY TJX)
FIN. FLOOR
5/8" PLYWOOD 1" INSUL.
VERTICAL CONTROL JOINT (USG CONTROL JOINT #093) 32'-0" O.C. SEE SPECIFICATION BOOK
NOTES:
FURNISH AND INSTALL HORIZONTAL STUDS TO RECEIVE PERIMETER CEILING ANGLE.
FURNISH AND INSTALL CONTINUOUS SHOE AND PLATE W/ HORZ. BLOCKING AT MID POINT OF STUD HEIGHT.
FOR WALLS HIGHER THAN FINISHED CEILING, BRACE TO UNDERSIDE OF STRUCTURE FOR WALL SUPPORT.
4'-0" X 8'-0" SHEETS OF PLYWOOD TO BE MOUNTED HORIZONTALLY. STAGGER ALL JOINTS AND EXTEND 6" ABOVE FINISHED CEILING.
FOR AREAS WITHOUT A CEILING, INSTALL 5/8" PLYWOOD TO 12'-0" A.F.F.
FOR CASH OFFICE, DEMISING AND APPLICABLE DRESSING ROOM WALLS 5/8" PLYWOOD TO EXTEND TO UNDERSIDE OF ROOF DECK.
INSULATION TO UNDERSIDE OF DECK AT ALL EXPOSED EXTERIOR DEMISING WALLS.
FOR WALLS FINISHED WITH OUTRIGGER OR SLATWALL SYSTEM REFER TO SECTION DETAIL (00/C3 OR 01/C3).
1
2
3
4
5
6
1 1/2" x 3 1/2" x 12'-0" WOOD STUD. INSTALL
ON FLAT SIDE WITH LAG OR TOGGLE
BOLTS @ 24" O.C. INSTALL BOTTOM OF STUD VERTICALLY 30" A.F.F.
MASONRY WALL
B C3
1 5/8" METAL FURRING CHANNELS, MOUNTED VERTICALLY
MASONRY WALL
1 5/8" METAL FURRING CHANNELS, MOUNTED VERTICALLY
MASONRY WALL
45/8" PLYWOOD
5 BATT. INSULATION TO UNDERSIDE OF DECK
6
45/8" PLYWOOD
1 3
D C3
MASONRY WALL
6
45/8" PLYWOOD
1 3
G1 C3
6" 20 GA METAL STUDS @ 16" O.C.
5/8" PLYWOOD CONTINUOUS FULL HEIGHT TO UNDERSIDE OF DECK
4
EXTERIOR WALL FINISH
6" 20 GA METAL STUDS @ 16" O.C.
5/8" PLYWOOD CONTINUOUS FULL HEIGHT TO UNDERSIDE OF DECK 4
INSTALL 3 1/2" THICK FIBERGLASS NOISE BARRIER BATTS TO UNDERSIDE OF DECK
5
1 3
6
T C3
1 3
6
U C3
1' -
6"
10 "
45/8" PLYWOOD TO 12'-0" AFF
3
6" 20 GA METAL STUDS @ 16" O.C.
14 GAUGE. 1" X 2" WIRE MESH INSTALLED ABOVE 12'-0" ON
STOCKROOM SIDE TO UNDERSIDE OF DECK. W2
C3
45/8" PLYWOOD TO 12'-0" AFF
3
6" 20 GA METAL STUDS @ 16" O.C.
14 GAUGE. 1" X 2" WIRE MESH INSTALLED ABOVE 12'-0" ON
STOCKROOM SIDE TO UNDERSIDE OF DECK.
WALL SYSTEM
3'
-6 "
5/8" GYP. BD. ALL
303
314
314
218
341
303
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
12 ' -
303
314
314
218
341
303
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
6
6 ½
REFER TO SLATWALL INSTALLATION INSTRUCTIONS FOR ORIENTATION OF SLATWALL PANELS AT COLUMNS
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
BOTTOM OF ROOF DECK
PAINT STRUCTURE ABOVE #303.
ADD FINISHED CORNER BEAD
6
REFER TO SLATWALL INSTALLATION INSTRUCTIONS FOR ORIENTATION OF SLATWALL PANELS AT COLUMNS
FINISH DIMENSION OF COLUMN TO BE 3" GREATER THAN STRUCTURAL COLUMN SIZE (12" X 12" MIN. FINISH DIM.)
DETAIL #1
1/4" MIRROR
SECTION B-B
OUTLET
E.T.M. CLEAR ANODIZED ALUMINUM CORNER GUARDS BY STYLMARK, MODEL #120058 CORNER COLUMN MOULDING, COLOR TO BE #020 SATIN NATURAL, NO SUBSTITUTIONS.
1/4" MIRROR TO BE INSTALLED ON ALL SIDES OF SALES AREA COLUMNS FROM 2'-4½" (TOP OF BUMPER) TO 8'-0". THE G.C. IS TO INSTALL A PLASTIC LAMINATE/PLYWOOD PANEL ON COLUMNS HAVING A SENSOR, EXTINGUISHER, OR TELEPHONE MOUNTED ON THE REAR SALES AREA SIDE. SEPARATION BETWEEN MIRROR & LAM. PANEL TO BE "STYLMARK" MIRROR DIVIDER TRIM # 420109. (SEE ELEVATION THIS SHEET)
THERMOSTAT SERVICE
TELEPHONE SERVICE
STRUCTURAL COLUMN.
DETAIL #2
1/4" MIRROR
LAMINATE ON 1/4" PLYWOOD
BLOCKING BEYOND (5/8" PLYWOOD)
3/8" WOOD BLOCKING @ COLUMNS ONLY
PAINTED 5/8" GYPSUM WALLBOARD.
NOTES:
1. PLYWOOD & LAMINATE PANELS TO BE INSTALLED ON THE BACK SIDE OF A COLUMN HAVING A TELEPHONE, FIRE EXTINGUISHER, OR SENSORS MOUNTED AT 54" A.F.F. ALL SIDES REQUIRE MIRRORS EXCEPT AT PLASTIC LAMINATE PANEL. REFER TO INTERIOR ELEVATION SHEET FOR FINISH OF PLASTIC LAMINATE PANEL. SEE ELEVATION, THIS SHEET.
2. MIRRORS SHALL BE LIBBY-OWENS-FORD MIRROR OR APPROVED EQUAL.
3. ALL SQUARE COLUMNS SHALL BE MIRRORED ON ALL FOUR SIDES FROM 2'-4½" (TOP OF BUMPER) TO 8'-0". (EXCEPT AT PLASTIC LAMINATE PANEL FOR PHONE, T-STATS)
4. ELECTRICAL OUTLETS ON COLUMNS IN SALES AREA TO BE 18" A.F.F. (CENTERED ON COLUMN) UNLESS OTHERWISE NOTED. LOCATE ON THE BACK SIDE OF COLUMN AWAY FROM THE AISLE. PLEASE REFER TO C6 (POWER PLAN) FOR SITE SPECIFIC LOCATIONS.
5. PROVIDE HORIZONTAL 2" X 4" WOOD BLOCKING BEHIND BUMPER MOLDINGS AT 6½" A.F.F. AND AT 24" A.F.F. SECURE BUMPER MOLDINGS TO WOOD BLOCKING IN WALL.
6. T-STAT, TELEPHONE AND FIRE EXTINGUISHER ARE ALWAYS TO BE MOUNTED ON THE SAME SIDE OF THE COLUMN MOUNTED ON PLASTIC LAMINATE PANEL. UNLESS OTHERWISE NOTED, LOCATE ON THE BACK SIDE OF COLUMN AWAY FROM THE AISLE. PLEASE REFER TO C6 (POWER PLAN) FOR SITE SPECIFIC LOCATIONS. COORDINATE FINAL LOCATIONS WITH TJX VENDORS
SECTION A-A
POINTS OF COLUMN.
E.T.M.
2
1 MIRROR 4 SIDES OF COLUMN FROM 2' - 0" (TOP OF BUMPER) TO 8' - 0". UNLESS NOTED OTHERWISESIZE VARIES W/ COLUMN SIZE. (12" MINIMUM WIDTH, TYP. )
ELECTRICAL OUTLET @
18" A.F.F.
6
X C3
1 1/2" x 3 1/2" WOOD STUD @16" O.C. OPEN TO CONSTRUCTION TO UNDERSIDE OF DECK
2
14 GAUGE 1" x 2" WIRE MESH. INSTALL ON STOCK ROOM SIDE.
CONFIRM ALL OUTRIGGER DIMENSIONS WITH THE INSTALLATION INSTRUCTIONS.
6" VINYL BASE
5/8" GYP. BOARD
5/8" GYP. BOARD
5/8" GYP. BOARD
SALES FLOOR TILE MUST BE COMPLETE PRIOR TO OUTRIGGER INSTALLATION.
SE E
C 5
SH EE
T FO
R C
EI LI
N G
H EI
G H
6" VINYL BASE
5/8" GYP. BOARD
5/8" GYP. BOARD
5/8" GYP. BOARD
SALES FLOOR TILE MUST BE COMPLETE PRIOR TO OUTRIGGER INSTALLATION.
SE E
C 5
SH EE
T FO
R C
EI LI
N G
H EI
G H
6" VINYL BASE
5/8" GYP. BOARD
5/8" GYP. BOARD
5/8" GYP. BOARD
"
NOTE: ALTERNATIVE FLUSH MOUNT "DANBACK" (CLARKDIETRICH) "FLEXIBLE WOOD" BACKING SYSTEM. IF THE ASSIGNED ARCHITECH/ENGINEER ELECTS TO USE THE ABOVE-MENTIONED APPLICATION, IT IS THEIR RESPONSIBILITY: TO ENSURE THE STUD WALL IS CONSTRUCTED PER USG CONTRUCTION WORKERS GUIDED AND/OR ASTM C745, THE MOUNTING SYSTEM IS INSTALLED PER DANBACK SPECIFICATIONS AND ANY ADDITIONAL WALL LOADS, NOT RELATED TO THE OUTRIGGER INSTALLATION HAVE BEEN TAKEN INTO STRUCTURAL CONSIDERATIONS.
DANBACK SYSTEM
C
NOTE: ARCHITECT/ENGINEER OF RECORD TO CHOOSE THE ATTACHMENT METHOD THAT BEST SUITS THE SITE SPECIFIC CONDITIONS.
12
' - 0
Store Number
Planned By
Deal Type
As indicated
C3 EL
03/11/21 KTL
JR/DEM
NOT TO SCALEC3 4B
TYPICAL CORNER BOXOUT SECTION
NOT TO SCALEC3 10
TYPICAL LOCKING STORAGE CAGE
NOT TO SCALEC3 8
TYPICAL CARRIAGE FLOOR BUMPER
NOT TO SCALEC3 5
NOT TO SCALEC3 01
NOT TO SCALEC3 03 TYPICAL SECTION AT SOFFIT
NOT TO SCALEC3 05
TYPICAL SECTION @ TOP CHANNEL
NOT TO SCALEC3 2
NOT TO SCALEC3 2A
TYPICAL COLUMN DETAILS (ACT)
NOT TO SCALEC3 3A
TYPICAL SLATWALL COLUMN (ACT)
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
NOT TO SCALEC3 00
341
303
305
303
305
341
305
C EI
LI N
G O
R R
O O
F D
EC K
EX TE
N D
W AL
LS T
O U
N D
ER SI
D E
O F
4 ' - 6"
4' -
6"
341 305
METAL STUD AND DRY WALL CONSTRUCTION
NOTE: ALL VERTICALLY TILED OUTSIDE CORNERS WITHIN THE RESTROOM TO BE FINISHED WITH SCHLUTER SYSTEM "RONDEC" PROFILE. (RO80AE FOR 8MM TILE)
INSTALL POWERED FAUCETS AT ALL SINKS, REFER TO TJX SPECIFICATION MANUAL,
INSTALL FLUSHOMETERS ON ALL WATER CLOSETS AND URINALS, REFER TO TJX SPECIFICATION MANUAL.
ADD URINAL SCREEN SUPPORT POST FROM FLOOR TO CEILING, IF REQUIRED. COORDINATE WITH TJX PROJECT MANAGER.
TOILET ACCESSORY LEGEND
1. CUP DISPENSER, MOUNTED AT 40" A.F.F. 2. AUTOMATIC SOAP DISPENSER, MOUNTED AT 40" A.F.F. (AT
THE OPERATING POINT.) 3. XLERATOR XL-SB ELECTRIC HAND DRYER, MOUNTED AT
40" A.F.F. (AT THE OPERATING POINT.) INSTALL XCHANGER COMBO KIT #40576.
4. OPTIONAL SANITARY NAPKIN DISPENSER, MOUNTED AT 40" A.F.F. (AT THE OPERATING POINT.) (DO NOT THRU BOLT INTO PARTITION.)
5. SANITARY NAPKIN DISPOSAL @ 15" A.F.F. 6. 5'-0" HIGH, 1/4" PLATE GLASS MIRROR OVER ENTIRE
WIDTH OF SINK COUNTERTOP. EDGE PROTECTED WITH 1/4" J-MOLDING. BOTTOM MOUNTED AT 38" A.F.F. (TOP OF BACKSPLASH)
7. DEODORANT HOLDER @ 96" A.F.F. 8. 36" GRAB BAR @ 36" A.F.F. 9. 42" GRAB BAR @ 36" A.F.F. 10. TOILET PAPER HOLDER @ 21" A.F.F. WITH DISPENSING
POINT LOCATED 7" TO 9" IN FRONT OF TOILET 11. SEAT COVER DISPENSER @ 40" A.F.F. DISPENSING @ 48"
A.F.F. 12. ASI 0458-DX SEMI-RECESSED WASTE RECEPTACLE. 13. TOILET PARTITION BY GLOBAL STEEL PRODUCTS. COLOR:
CHARCOAL #2123. PARTITION DOORS TO HAVE SOLID WOOD CORES. ALL PARTITION DOORS TO HAVE A COAT HOOK / BUMPER, MOUNT 48” MAX. AT HP STALL DOORS, AND 66” MAX FOR NON HP STALL DOORS.
14. TOP OF TOILET SEAT @ 17"-19" A.F.F. 15. BABY CHANGING STATION MOUNTED WHEN OPEN THE
TOP SURFACE IS 33" A.F.F. WHEN CLOSED THE PULL SHOULD BE NO HIGHER THAN 48" A.F.F.
16. RESTROOM ENTRY THRESHOLD TRANSITION. SCHLUTER RENO-RAMP AERP100B65 (ANODIZED ALUMINUM)
17. URINAL SCREEN BY GLOBAL STEEL PRODUCTS. COLOR: CHARCOAL #2123.
18. 48 INCH HIGH STAINLESS STEEL CORNER GUARDS, AS SUPPLIED BY ATR SALES INC FOR EWC
MEN'S
WOMEN'S
14
10
9
.C .
2
BACKSPLASH
1/2" x 3" PLYWOOD APPLIED HORIZONTAL TO BRACKETS FOR ATTACHMENT OF FRONT PANEL.
DROP-IN LAVATORY SINK OR KITCHENETTE SINK
BLOCKING AS REQUIRED
G.C. TO FASTEN WITH STAINLESS STEEL SCREWS AND GROMMETS.
NOTE: G.C. MUST INSTALL LAMINATED SKIRT PANEL AS SHOWN TO MEET ADA DIMENSIONAL CLEARANCES (NOTIFY PROJECT MANAGER IF FIELD CONDITIONS PROHIBIT INSTALLATION.)
• RESTROOM COUNTER • LAMINATE FRONT BOTTOM EDGE
• KITCHENETTE COUNTER • LAMINATE FRONT BOTTOM EDGE
POSTFORM LAMINATED COUNTERTOP FINISH NOTE:
• RESTROOM SKIRT
FINISH NOTE:
318 FINISH NOTE:
5
/8 "
2"
3/4" PLYWOOD BRACKET SUPPORTS. (1) AT EACH END OF TOP & (1) AT MIDPOINT.
4
RAKKS #EH1818 SUPPORT BRACKET (CLEAR ANODIZED)
NOTE: FOR STANDARD 6' - 6" LENGTH TOP (3) SUPPORT BRACKETS ARE REQUIRED - SPACE EVENLY. IF STANDARD LENGTH DOES NOT APPLY, SPACING/AMOUNT OF SUPPORT BRACKETS TO BE DETERMINED BY TJX P.M.
FINISHED FLOOR
BUILD OUT 1/2"
3
A
2
2
5' -
6"
CORNER GUARDS (TYP) @ ALL 90° CORNERS SHALL RECEIVE PAWLING CLEAR LEXAN STYLE #CG-17, 1 1/8" X 1 1/8" X 4'-0" LENGTH (EXCEPT BOXED COLUMNS AT 5'-0" A.F.F.). NO SUBSTITUTIONS. ALL CORNER GUARDS TO BE FASTENED TO WALL WITH SCREWS. NO ADHESIVES.
NOTE: ALL DOORS AND FRAMES NOT SHOWN ON THE ELEVATION SHEET (C4) TO BE PAINTED SAME COLOR AS SALES FLOOR DOORS AND FRAMES.
SPECIFICATIONS FOR V.W.C. INSTALLATION
NEW CONSTRUCTION: THE G.C. SHALL SEE THAT SURFACES PRESENT A TRUE SMOOTH, LEVEL FINISH FREE FROM CRACKS, DIRT, DUST, RREGULARITIES, ROUGH SPOTS AND INDENTATIONS. A GOOD QUALITY NAMED BRAND WHITE OIL BASED PRIMER SHALL BE USED ON ALL NEW DRYWALL TO EASE APPLICATION AND FUTURE REMOVAL.
RENOVATIONS: OLD WALLCOVERING SHALL BE REMOVED AND WALLS ARE TO BE WASHED AND SANDED TO REMOVE ANY OLD ADHESIVE. IF NECESSARY THEY SHALL BE RE-PRIMED WITH AN OIL BASED WHITE PRIMER.
ADHESIVE: GUARD FC-100 OR ANY OTHER GOOD QUALITY HEAVY DUTY ADHESIVE IS RECOMMENDED.
DO NOT "RAILROAD" VINYL WALL COVERING.
ALL WORK SHALL BE COMPLETED IN A NEAT AND PROFESSIONAL MANNER.
AF F
325
SLATWALL PANEL SYSTEMS:
REFER TO SECTION 6A OF THE OUTLINE SPECIFICATION FOR WORK RESPONSIBILITY REGARDING SLATWALL PANEL SYSTEM.
INSTALLATION INSTRUCTIONS FOR PREFABRICATED WALL PANEL (SLATWALL) AND METAL SLATWALL COMPONENTS ARE INCLUDED AS A PART OF THE PACKAGE. IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO BECOME FAMILIAR WITH THESE INSTRUCTIONS PRIOR TO PROVIDING A PRICE OR COMMENCEMENT OF WORK.
8" REVERSE CUT WHITE VINYL LOGOTO 36" A.F.F. 325
3
6 "
AF F
PANEL LEGEND
PANELS DIMENSIONS ILLUSTRATE THE CENTER LOCATION OF METAL UPRIGHT. SEE FOR MFG. INSTRUCTIONS FOR INSTALLATION.
DIMENSION SEE PLAN FOR
11/16" X 1-1/2" x 8'-1" PAINTED PRMD MDF BOARD (TYP)
PAINT 1 ½" GAP
MIRROR EDGES FINISHED WITH L-BAR IN SATIN FINISH, 5/8"X 3/8".
DRESSING ROOM
11/16" X 1-1/2" x 8'-1" PAINTED PRMD MDF BOARD (TYP)
303
EXTENT OF WALL TILE
27" MIN (H) OF KNEE SPACE UNDER SINK (MEASURED FROM A POINT 8" FROM THE FRONT EDGE OF THE COUNTER EXCLUDING THE OVERFLOW)
9" MIN (H) OF TOE SPACE THAT EXTENDS 17" MIN UNDER THE SINK (MEASURED FROM THE FRONT EDGE OF THE COUNTER.)
A 30" X 48" CLEAR FLOOR SPACE AT THE ACCESSIBLE SINK THAT EXTENDS 17" MIN UNDER THE COUNTER.
PIPES AT ACCESSIBLE SINK MUST BE INSULATED.
TOILET PARTITION
EDGE OF WALL DUE TO TILE ON THE
ADJACENT WALL
34" MAX A.F.F. WITH 4" BACKSPLASH.
6
339
BULLNOSE
339
130
303
MIN 4"6' - 1"40' - 5"
G.C. NOTES: UPPER GLAZING @ DOOR TRANSOMS ON SALES SIDE SHALL RETAIN A 1" GAP BETWEEN GLAZING AND VERTICAL FRAMES TO ELIMINATE NEGATIVE AIR PRESSURE IN VESTIBULE. GLASS TO BE RADIUSED AND GROUND SMOOTH ON BOTH SIDES.
BUMPER RAIL @ 40 1/2" A.F.F.
341 341 341 341 341
303 303
314
EQEQ
8' -
4"
MIN 4"
MIN 4"8' - 1"3' - 0 1/2"
MIN 7"
341 341
341
MIN 5 1/2"
MIN 4"
- 48 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
- 36 ½" OUTRIGGER3 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER8 SEE DETAIL 00/C3 FOR INSTALLATION
- 36 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
11/16" X 1-1/2" x 8'-1" PRMD MDF BOARD PAINTED #303 (TYP
BUMPER RAIL @ 24" & 6 1/2" AFF
SEE DETAIL 7/C4 FOR DRESSING ROOM
INTERIOR FINISHES.
303 303
303 RETURN
9' -
0"
8' -
6"
10 ' -
6 "
MIN 4" 8' - 1" 6' - 1" 1' - 4" 1' - 6"20' - 2 1/2"
MIN 4" 1' - 6" 12' - 1 1/2"
MIN 4" 1' - 6" 1' - 6"
4' - 0 1/2" MIN 4"
- 48 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
- 36 ½" OUTRIGGER2 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER5 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER3 SEE DETAIL 00/C3 FOR INSTALLATION
- 48 ½" OUTRIGGER1 SEE DETAIL 00/C3 FOR INSTALLATION
341 341 341 341 341
341
305
305
10 ' -
6 "
2' -
6"
303 303 303
EQEQ
10 ' -
6 "
MIN 4"
4' - 0 1/2" 9' - 1 1/2" 2' - 0" 1' - 6" MIN 4" 44' - 5 1/2" 3' - 0 1/2"
MIN 4"
BUMPER RAIL @ 40 1/2" A.F.F.
314
341
305
303
Scale
Date
Store Number
Planned By
Deal Type
As indicated
C4 EL
03/11/21 KTL
INTERIOR ELEVATIONS
NEWPORT, TN
JR/DEM
NOT TO SCALEC4 1A
TYPICAL SECTION @ COUNTER TOP
NOT TO SCALEC4 1B
NOT TO SCALEC4 7
NOT TO SCALEC4 8
NOT TO SCALEC4 9
MARSHALLS FINISH SHEDULE FINISH
TILE ARMSTRONG STANDARD EXCELON #51810 WASHED
LINEN 108 VINYL COMPOSITION
TILE ARMSTRONG STANDARD EXCELON #57501 NOUGAT
112 PAINT BENJAMIN MOORE #0P22 SUPER SPEC URETHANE ALKYD GLOSS ENAMEL BASE: 3B / COLOR: DECK GRAY WITH SAND ADDED FOR NON-SLIP FINISH
113 PAINT BENJAMIN MOORE REGAL #968 "DUNE WHITE" (SEMI-GLOSS 333)
115 ENTRANCE GRID MATTING
MATWORKS AMBASSADOR - TF - CHARCOAL WITH TF TAPE
117 PAINT BENJAMIN MOORE #OC-161 "CEDAR KEY" (SEMI-GLOSS) 130 COVE BASE SCHLUTER
SYSTEMS DILEX-AHK (AHK1S100AE), MATERIAL: SATIN ANODIZED ALUMINUM, SIZE: 100 (3/8 - 10 MM). OUTSIDE CORNERS 90 DEGREES - E90/AHK1S100AE STAIN ALUMINUM. CUSTOMER SERVICE 800-472-4588
137 EIFS DRYVIT #310 "CHINA WHITE" 138 PAINT BENJAMIN MOORE CLOUD WHITE #967. PAINT TO MATCH
CHINA WHITE DRYVIT. (EGGSHELL) 211 NON-SLIP VINYL
COMPOSITION ARMSTRONG SLIP RETARDANT #57005 STONE BEIGE
TILE 218 CORNER GUARD PAWLING CLEAR LEXAN STYLE #CG-17, 1 1/8" X 1
1/8" X 4'-0" LENGTH ALL CORNER GUARDS TO BE FASTENED TO WALL WITH SCREWS. NO ADHESIVES.
219 CORNER GUARD WINDMILL INSIDE/OUTSIDE CORNER MOULDING, #3652 COLOR: (FOR SLATWALL COLUMNS IN MXMR) WHITE - NO SUBSTITUTIONS
238 LAMINATE FORMICA POSTFORMED SURFACE, #86992-58 HARDROCK MAPLE
251 VINYL BUMPER RAIL MCCUE #609 "DARK PUTTY", 2" IN DIAMETER 303 PAINT BENJAMIN MOORE #0C-65 "CHANTILLY LACE",
- OFFICES, DOORS/FRAMES, RESTROOMS, COLUMNS & SUPPORT (SEMI-GLOSS) - SALES FLOOR & EXTERIOR (EGGSHELL)
304 PAINT BENJAMIN MOORE #OC-68 "DISTANT GRAY" (SEMI-GLOSS) 305 PAINT BENJAMIN MOORE #2061-20 "CHAMPION COBALT"
(EGGSHELL) 308 VINYL COMPOSITION
TILE ARMSTRONG #51899 COOL WHITE, 12" X 12" X 1/8"
IMPERIAL TEXTURE 311 LUXURY VINYL TILE AMTICO W684 - MAPLE (NON-BEVELED EDGE)
6"x36" PLANK IN 3.2 MM THICKNESS (1/8") 312 LUXURY VINYL TILE AMTICO W738 - PALISANDER (NON-BEVELED
EDGE) 6"x36" PLANK IN 3.2 MM THICKNESS (1/8")
313 VINYL BUMPER RAIL MCCUE #111 SILVER, 2" DIAMETER 314 VINYL BUMPER RAIL MCCUE #111 SILVER, 1" DIAMETER 315 BEAD BOARD WALL
SYSTEM DGS RETAIL MARSHALLS HOME AREA BEAD BOARD
WALL SYSTEM 317 LAMINATED PANEL DGS RETAIL #1573-60 FROSTY WHITE 318 PLASTIC LAMINATE WILSONART POSTFORMED SURFACE #4779-60
PEWTER BRUSH 303. LAVATORIES SHALL BE MOUNTED SELF RIMMING VITREOUS CHINA WITH 8" CENTER SET SUPPLY WITH AERATOR, AND A FLAT PERFORATED STRAINER LAVATORY WASTE DRAIN.
319 LAMINATE (FRONT-LINE)
322 DOUBLE SLOTTED SLATWALL
DGS RETAIL BAUSCH LINNEMANN HARDROCK MAPLE WM791 SUEDE 6" SLAT PANELS
323 FRP MARLITE STANDARD FRP FINISH, PEBBLED SURFACE, P100 WHITE. 4'-0" HIGH WAINSCOTING ON ALL WALLS (EXCLUDING NYC RESTROOMS, GOES TO CEILING AND 8'-0" HIGH WAINSCOTING ABOVE MOP SINK AREA ONLY)
324 LAMINATE PANEL WILSONART #1573-60 "FROSTY WHITE" 325 VINYL DGS RETAIL INC. MARSHALLS - 3M DARK BLUE 326 SPANDREL GLASS SOLAR SEAL
COMPANY 1" CLEAR/CLEAR WITH SPANDREL. 1/4" CLEAR WITH 6-0025 HARMONY BLUE (2). 1/2" AIR SPACER. 1/4" CLEAR
327 EIFS DRYVIT #449 "BUCKSKIN" (SANDBLAST) 328 PAINT BENJAMIN MOORE #965 "TEMPORAL SPIRIT". PAINT TO
MATCH "BUCKSKIN" DRYVIT. (EGGSHELL) 329 EIFS DRYVIT #112 "SANDLEWOOD BEIGE" (SANDBLAST) 330 EIFS DRYVIT #578 "MIDNIGHT BLUE" (SANDBLAST) 332 CROWN MOULDING N/A WPRB3-PFJ PRIMED PINE 830345 CASING,
PAINT #304 333 BEAD BOARD DGS RETAIL INC. 1/2" UNIVERSAL BEAD BOARD WALL
COVER PANEL 334 WALLCOVERING MDC
WALLCOVERING CANDACE OLSEN, "ROMANCE EBONY" #TJX 2107 (MENS) NOTE: WALL COVERING TO MATCH UP AT REPEATS
335 WALLCOVERING MDC WALLCOVERING
CANDACE OLSEN, "ROMANCE STEEL" #TJX 2112 (WOMENS) NOTE: WALL COVERING TO MATCH UP AT REPEATS
336 VINYL BUMPER RAIL MCCUE ANTIQUE RED FAUX BRICK 337 VINYL BUMPER RAIL MCCUE BRIGHT WHITE FAUX BRICK 338 LAMINATED PANEL SUNBRELLA MARINE BLUE 339 CERAMIC TILE DALTILE 12" X 12" DB VOLUME 1.0, STEREO GREY,
WALL TILE #VL73, INSTALLED VERTICALLY. WITH 3" X 12" MATCHING BULLNOSE MOLDING #P-43C9. GROUT BY LATICRETE, #89 "SMOKE GREY" (3/16").
340 CERAMIC TILE DALTILE 12" X 12" DB INDUSTRIAL PARK, CHARCOAL GRAY, FLOOR TILE #IP09. GROUT BY LATICRETE, #42 "PLATINUM" (3/16").
341 VINYL COVE BASE TARKETT TA4 "GATEWAY", 6" 342 VINYL COVE BASE TARKETT #31 "ZEPHYR", 6" 343 PAINT BENJAMIN MOORE #110 CORONADO SUPER KOAT 500 DRY
FALL LATEX PAINT FLAT, TINTED TO BENJAMIN MOORE, #OC 65 "CHANTILLY LACE".
407 VINYL BUMPER RAIL MCCUE #604 LIGHT CARAMEL, 1" DIA.
NOT TO SCALE0A PARTIAL ELEVATION AT ENTRANCE
NOT TO SCALE0B SECTION AT ENTRANCE
NOT TO SCALEC4 A
NOT TO SCALEC4 D TYPICAL WALL ELEVATION
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
NOT TO SCALEC4 C HAND DRYER ELEVATION
1/8" = 1'-0"C4 01 FRONT LINE ELEVATION
1/8" = 1'-0"C4 02 SHOES A ELEVATION
1/8" = 1'-0"C4 03 SHOES B ELEVATION
1/8" = 1'-0"C4 04 DRESSING ROOM ELEVATION
1/8" = 1'-0"C4 05 HOME ELEVATION
1/8" = 1'-0"C4 06 KID'S & MEN'S ELEVATION
NOT TO SCALEC4 00 STORE LOGO
E
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
END
A
T4L (TYP. OF 9)
T4L (TYP. OF 9)
G3 G3 G3
A6 A6
A6 A6
A6 A6
BABY
NL A A A
L1 L1
120" AFF
ALL SOFFIT, VALANCE, DISPLAY, & FOCAL WALL LIGHTING TO BE CONSIDERED "CUSTOMER LIGHTING" & CONTROLLED BY NOVAR, THROUGH THE CONTACTOR RELAY PANEL.
ALL TRACK IS TO BE MOUNTED ON UNISTRUT. ALL UNISTRUT TO BE PAINTED WHITE AND HUNG AS REQUIRED FROM STRUCTURE ABOVE. ALL TRACK USED IN THE STORE IS TO BE WIRED FROM 120V PANEL.
ELECTRICAL J-BOX FOR ALL OVERHEAD TYPE LIGHTS TO BE WITHIN 4' OF EACH ACTUAL LIGHT FIXTURE.
PAINT # 343 UNDERSIDE OF DECK, ALL EXPOSED PIPES, DUCTS, CABLES, CONDUITS, UNISTRUT, ETC.
2" WIDE UNISTRUT SUPPORTED FROM STRUCTURE ABOVE. BOTTOM OF UNISTRUT FOR SIGNAGE MOUNTED 12'-0" A.F.F. GC TO COORDINATE EXACT PLACEMENT WITH TJX PROJECT MANAGER AND FIELD OPERATIONS.
NOTE: TIE HALL LIGHTS IN WITH EMPLOYEE LIGHTING CIRCUIT
CEILING HEIGHT = 10' - 2" A.F.F.
A.C.T. CEILING HEIGHT = 10' - 6" A.F.F.
TOP OF TRACK TO BE INSTALLED 8" HIGHER THAN GENERAL LIGHTING.
ALL TRACK IS TO BE MOUNTED ON UNISTRUT.
ALL UNISTRUT TO BE PAINTED WHITE AND HUNG AS REQUIRED FROM STRUCTURE ABOVE.
ALL TRACK USED IN THE STORE IS TO BE WIRED FROM 120V PANEL.
NOTE: LIGHTING PATTERN MUST REMAIN AS DRAWN AND ADHERE TO THIS PLAN. ALL LIGHT FIXTURES IN SALES AREA WILL BE MOUNTED @ 12' - 0" A.F.F. TO THE UNDERSIDE OF THE FIXTURE. (SEE EXCEPTIONS). LANDLORD ARCHITECT MUST COORDINATE ALL M.E.P. TRADES TO ENSURE. PLEASE CONTACT TJX PROJECT MANAGER AND M.O.D. IMMEDIATELY IF THERE ARE ANY FIXTURE SPACING OR MOUNTING HEIGHT CONFLICTS. TJX WILL NOT BE RESPONSIBLE FOR COSTS INCURRED FOR INCORRECT INSTALLATION AND MOUNTING OF LIGHT FIXTURES WITHOUT PRIOR NOTIFICATION TO TJX P.M. OR M.O.D..
LIGHTS TO BE MOUNTED AT 12' - 0 " A.F.F. MECHANICAL, ELECTRICAL, AND PLUMBING TO BE MOUNTED WITH ADEQUATE CLEARANCE BETWEEN TOP OF LIGHTING FIXTURES AND ROOF DECK.
WHEN DIMMING IS REQUIRED BY LOCAL JURISDICTION, REFER TO TITLE 24 MEP EXAMPLE PLANS.
2 C5
2 C5
1
2
3
4
5
3' -
8' -
T4L (TYP. 1 THRU 9) T4L (TYP. 1 THRU 9)
POSITION TRACK HEADS 2, 5 AND 8
TO ILLUMINATE GRAPHICS
CROSS-ILLUMINATE MERCHANDISE
S E
E C
5 S
H E
E T
FO R
C EI
LI N
G H
EI G
H T
2' X 4' ACOUSTICAL SUSPENDED CEILING OVER VESTIBULE
2
SE E
C 5
FO R
LI G
H T
FI XT
U R
E H
EI G
H T
3' - 6"
EST. YEAR
SE E
C 4
FO R
M O
U TI
N G
H EI
G H
3' - 6"
SE E
C 5
FO R
LI G
H T
FI XT
U R
E H
EI G
H T
CITY NAME
SINGLE OCCUPANCY SENSOR SWITCH (PIR) (REFER TO TJX SPECIFICATIONS FOR PRODUCT INFORMATION.)
SINGLE POLE SWITCH.
LEGEND
UNISTRUT
LIGHTING NOTES:
1. STORE LIGHTING (SALES & SUPPORT) SHALL INCORPORATE QUANTUM ELM2 TYPE FIXTURES TO ACT AS EMERGENCY LIGHTS. NUMBER OF FIXTURES TO BE DETERMINED BY CODE.
2. NL-FIXTURES WILL BE WIRED BEFORE A SWITCH OR CONTACTOR. (FIXTURES WILL RUN 24 HOURS)
3. LAYAWAY STOCK & PROCESSING ROOM LIGHTING TO BE MOUNTED AT 13' AFF. (LIGHTING TO BE COORDINATED WITH HVAC & STRUCTURAL STEEL)
4. TYPE A4 PENDANT LIGHTING FITTED WITH LOCKING PLUG. (NEMA L5-20P 20A, 125V, NEMA L7-20P 20A, 277V) E.C. TO FURNISH AND INSTALL APPROVED LOCKING RECEPTACLE AT OPEN DECK CEILING, PER REQUIRED VOLTAGE. (NEMA L5-20R 20A, 125V, NEMA L7-20R 20A, 277V)
5. HANGING SIGNS PROVIDED AND INSTALLED BY TJX.
6. SECURE EXCESS CORD WITH TIE STRAP ABOVE LIGHT FIXTURE. COORDINATE WITH TJX PROJECT MANAGER.
A6 AIMING ANGLE TABLE Mounting Height (Ceiling Height)
Distance off the Wall Desired Angle
10'-0" 3'-6" 41°
11'-0" 3'-6" 35°
12'-0" 3'-6" 30°
13'-0" 3'-6" 27°
14'-0" 3'-6" 24°
15'-0" 3'-6" 21°
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C5 EL
03/11/21 KTL
JR/DEM
SYSTEM WATTAGE
SYSTEM VOLTAGE
SPECIFICATION NUMBER (ORDERING INFORMATION) COMMENTS
A 188 2' X 4' 37 MULTI-VOLTAGE RECESSED LED ACUITY (LITHONIA)
2ESL4 48L EZ1 LP835 NATJ
A6 52 5-1/2" X 3-7/8" 57 120V TRACK LED CONTECH CTL184V35D-P SEE AIMING ANGLE TABLE, C5 SHEET. B 1 DOCKLIGHT 18 120V WALL
MOUNTED LED CRESENT DCF40CP3 (Dock Swing Arm),
LED18DP38W830/25 (GE Lamp) DOCKLIGHT
D 4 2' X 4' 37 MULTI-VOLTAGE RECESSED LED ACUITY (LITHONIA)
2ESL4 F 48L EZ1 LP835 NATJ FOR GYPSUM BOARD CEILINGS, AND FLANGE KITS
E 6 EXIT SIGN 4.3 MULTI-VOLTAGE WALL MOUNTED
LED ACUITY (LITHONIA)
LHQM-LED-R-120/277 QUANTUM LHQM EXIT SIGN/EMERGENCY LIGHT COMBO
F3 1 4" X 8' 53.4 MULTI-VOLTAGE SURFACE LED HUBBELL (COLUMBIA)
LSRK8-4W-40VW-FA-EDU-HSG8-CSHC
G3 11 4" X 8' 53.4 MULTI-VOLTAGE PENDANT LED HUBBELL (COLUMBIA)
LSRK8-4W-40VW-FA-EDU-HSG8-CSHC REQUIRES INDEPENDENT SUPPORTS TO THE STRUCTURE EVERY 4'-0
L 3 16" X 9-5/8" 32 MULTI-VOLTAGE WALL MOUNTED
LED EATON (SURELITE)
LDWP-GL-4B-ED-EMLED-CD MOUNT FIXTURE AT 7'-6" AFF OR PER LOCAL CODE
L1 13 16" X 9-5/8" 32 MULTI-VOLTAGE WALL MOUNTED
LED EATON (SURELITE)
LDWP-GL-4B-ED MOUNT FIXTURE AT 7'-6" AFF OR PER LOCAL CODE
O7 26 2' X 2' 20.2 MULTI-VOLTAGE RECESSED LED ACUITY (LITHONIA)
2RTL2 20L EZ1 LP830
R 49 EMERGENCY 1.5 MULTI-VOLTAGE SURFACE LED ACUITY (LITHONIA)
ELM2L CAN USE ELM6-LED, ELM-LT, or other Emergency lights in the Acquity ELM family
T4L 60 2-7/8" X 2-1/16" 17 120V TRACK LED PHILIPS/CONT ECH
CTL603-P (LAMP HOLDER), 435362 (PHILIPS LAMP)
TRACK MOUNTED SPOT LIGHT, 17PAR38/S15 3000 DIM AF SO
NOT TO SCALE
NOT TO SCALEC5 2
NOT TO SCALE
NOT TO SCALE
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
144"
18" B
54" 18"
FOCAL WALL SAVING NEVER LOOKED SO GOOD
FO CA
L W
AL L
LO VE
T HE
L AB
EL A
ND T
HE P
RI CE
FO CA
L W
AL L
BR AN
D NA
M ES
F OR
L ES
41"
J
J
B
D
B
C
B
E
T
S
F
J
PP
B
F
DEDICATED DUPLEX RECEPTACLE AT 12" A.F.C. FOR STORE SECURITY SYSTEM NOTE: LOCATED NEAR THE DOOR
COORDINATE EXACT LOCATIONS WITH TJX PROJECT MANAGER.
WEATHERPROOF PUSH BUTTON (SEE SPEC. DWG. C7)
REAR DOOR ALARM (SEE SPEC. DWG. C7)
OUTLET AT 18" A.F.F. FOR REWRAP TABLE
DUPLEX RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON THE SAME CIRCUIT THROUGHOUT CASH REGISTER AREA. (TYP.)
DEDICATED LINE WITH APPROPRIATE VOLTAGE AND DISCONNECT FOR FINAL CONNECTION TO COMPACTOR. 460V REQUIRES A 30 AMP DISCONNECT, 208V OR 230V REQUIRES A 60 AMP DISCONNECT. ELECTRICAL RUN AND A FUSED DISCONNECT WILL BE INSTALLED ON THE OUTSIDE OF THE BUILDING WITHIN 50' AND IN CLEAR SIGHT OF THE UNIT.
COORDINATE "WALL MOUNTED" ELECTRICAL WITH CASH CABINET LOCATION. IF STOREFRONT GLASS EXISTS BEHIND CABINET, FIELD VERIFY MOUNTING HEIGHT OF ELECTRICAL WITH TJX PROJECT MANAGER.
G.C. TO COORDINATE ELECTRIFIED STORE FIXTURES WITH DEPARTMENT LAYOUTS FROM THE FINAL FIXTURE PLAN.
EXTERIOR SIGN: FOR EACH EXTERIOR SIGN, ELECT. CONTRACTOR SHALL PROVIDE (3) 20 AMP, 120 VOLT CIRCUITS TO (3) THREE-GANG BOXES. MIDDLE J-BOX CENTERED ON SIGN FIELD. REMAINING J-BOXES AT 10'-0" TO CENTERLINE, EITHER SIDE. CONTROLLED BY BMS CONTACTOR. COORDINATE EXACT LOCATION OF CIRCUITS WITH TJX SIGN VENDOR AND TJX PM. SEE SPEC 16A.
PROVIDE CONDUIT AND (2) J- BOXES WITH BLANK PLATES AT LOCATION OF FIRE ALARM PANEL.
THREE (3) 2 1/2" CONDUITS TO BE CONCEALED IN FLOOR & WALL ON SALES AREA SIDE.
CONDUIT TERMINATION POINT. LOCATED UNDER CASH REGISTER COUNTER.
J-BOX FOR DRESSING ROOM MIRRORS (TYP.) CONNECT TO CUSTOMER LIGHTING CIRCUIT.
COORDINATE HEIGHT & LOCATION FOR ELECTRIC DRYER WITH TJX PROJECT MANAGER
NOTE: VERIFY ELECTRIC STRIKE LOCATION WITH MARSHALLS PROJECT MANAGER FOR EACH PROJECT
EDWARDS SIGNALING BUILDERS CHIME KIT C212 SERIES
OUTLET FOR TIMECLOCK
1 C6
PROVIDE 20 GAL. WATER HEATER W/ QUICK RECOVERY MOUNTED O ABOVE SINK SET TEMP. @ 105 F. TO BE MOUNTED BELOW FINISHED CEILING
COORDINATE EXACT LOCATIONS WITH TJX PROJECT MANAGER.
ALL ELECTRICAL DEVICE COVERS TO BE BRUSHED ALUMINUM
COORDINATE BURGLAR ALARM LOCATION WITH TJX PROJECT MANAGER
3/ 4"
C O
N D
U IT
C O
N N
EC TI
N G
IN TE
R IO
R A
N D
E XT
ER IO
R J
-B O
5' - 11 1/2"
2' -
1/ 2"
3 C6
3 C6
3 C6
SINGLE DEDICATED OUTLET TO BE MOUNTED TO END CHECKOUT UNIT. SEE DETAIL ON C7 SHEET.
DEDICATED OUTLET FOR SODA COOLER
G.F.I.
J-BOX FOR CUSTOMER COUNTER. INSTALL 6" ABOVE BOTTOM OF LIGHT FIXTURE
HEIGHT
DEDICATED DUPLEX OUTLET FOR FUTURE CART CONTAINMENT SYSTEM. (LOCATE 6"
ABOVE VESTIBULE FINISHED CEILING) CENTERED BETWEEN INTERIOR DOORS.
CONTINUOUSLY ELECTRIFIED AND NOT CONTROLLED BY A SWITCH
NOTES:
G.C. RESPONSIBLE TO CONTRACT "STANLEY ACCESS TECHNOLOGIES" TO PROVIDE & INSTALL VESTIBULE DOORS.
G.C. / E.C. RESPONSIBLE FOR ALL FINAL CONNECTIONS TO DOORS.
G.C. ELECTRICIAN TO PROVIDE (1) 120 V. 20 AMP DEDICATED CIRCUIT FOR THE
INTERIOR SET OF DOORS AND (1) 120 V. 20 AMP DEDICATED CIRCUIT FOR THE
EXTERIOR SET OF DOORS. ( LOCATE 6"ABOVE FINISHED CEILING) (1) 10 AMP LINE
TO EACH DOOR OPERATOR. ELECTRICAL TERMINATIONS BY E.C.
G.C. / E.C. TO PROVIDE A 110 VAC, CONTINUOUSLY ELECTRIFIED AND NOT CONTROLLED BY A SWITCH, QUAD OUTLET AT THE CONDUIT TERMINATION POINT ABOVE THE VESTIBULE CEILING. G.C. / E.C. TO PROVIDE AN 18" x 18" (MINIMUM) ACCESS PANEL AT THIS LOCATION IN THE EVENT THE VESTIBULE IS A HARD CEILING.
6' - 0" ± 3' - 4" 6' - 0"
1" CONDUIT INSTALLED FROM JUNCTION BOX TO MULLION. CONDUIT WILL START AT THE JUNCTION BOX AND WILL ROUTE ACROSS THE FLOOR TO THE MULLION IN THE VESTIBULE. CONDUIT WILL TRANSITION FROM THE FLOOR TO THE INSIDE OF THE MULLION. CONDUIT WILL ROUTE UP THE INSIDE OF THE MULLION TO THE VESTIBULE CEILING ABOVE. CONDUIT WILL TERMINATE APROX 6" ABOVE THE VESTIBULE CEILING AT THE AC OUTLET LOCATION.
JUNCTION BOXES TO BE INSTALLED PERPENDICULAR TO THE SLIDING DOOR FRAMES. JUNCTION BOXES (WITH COVERS) TO BE INSTALLED FLUSH WITH THE FINISHED FLOOR. JUNCTION BOXES TO BE INSTALLED AT 24" (2'-0") BACK FROM THE INSIDE SLIDING DOOR EDGE TO THE CENTER OF THE JUNCTION BOX. JUNCTION BOXES TO BE INSTALLED AT 72" (6'-0" CENTER TO CENTER, ALIGNED WITH THE EDGE OF THE DOOR OPENING.
2' -
0"
LOW VOLTAGE WIRING CONDUIT & JUNCTION BOX BY G.C. W/PULL WIRE. (WIRING BY OTHERS)
POWER POLE
EXTERIOR SIGN JUNCTION BOX.
CHIME WITH LOW VOLTAGE TRANSFORMER CENTERLINE 94" AFF, UNLESS OTHERWISE NOTED.
BELL WITH LOW VOLTAGE TRANSFORMER, CENTERLINE 90" AFF.
TELEPHONE-DESK SET.
TELEPHONE-WALL HUNG.
DUPLEX RECEPTACLE WITH ISOLATED GROUND.
QUADRUPLEX RECEPTACLE WITH ISOLATED GROUND
BLANKED OUTLET WITH 3/4" EMT RUN UP WALL TO ABOVE SUSPENDED CEILING. HEIGHT AS NOTED.
QUADRUPLEX OUTLET
QUADRUPLEX RECEPTACLE
DUPLEX RECEPTACLE
SIMPLEX RECEPTACLE
EXHAUST FAN
ELECTRIC STRIKE
COMPACTOR DISCONNECT
PHONE/DATA JACK
DOOR BUZZER
SIMPLEX OUTLET
PLUG MOULDING
NEMA RECEPTACLE
RESTROOM, LOUNGE, JANITOR, & DRESSING ROOM (WHEN APPLICABLE) EXHAUST FANS, WILL BE A CONTROLLED/SWITCHED CIRCUIT, RUN THROUGH THE GE LIGHTING RELAY PANEL ON THE "EMPLOYEE" CIRCUIT.
WHEN REQUIRED, ELECTRIC ROOM AND/OR SYSTEMS ROOM EXHAUST FANS WILL BE A 24 HOUR LIVE CIRCUIT CONTROLLED BY IN LINE THERMOSTAT SET AT 80° DEGREES. SEE SPEC. BOOK FOR ADDITIONAL INFORMATION.
FINISHED FLOOR
NOTE: MAXIMUM OF 5 FANS PER CIRCUIT.
EACH FAN CONTROLED BY A TIMER SWITCH. SWITCH MOUNTED AT 4'-0" AFF.
FAN SPEC: TPI CACU-24W
FAN AND TIMER SWITCH PURCHASED BY G.C.
TIMER SWITCH
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C6 EL
03/11/21 KTL
POWER PLAN
NEWPORT, TN
JR/DEM
NOT TO SCALEC6 3
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
NOVAR INTERFACE SUMMARY (REFER TO TJX SPECIFICATIONS FOR DETAIL INFORMATION)
1. GENERAL CONTRACTOR A. PROVIDE AND INSTALL A 4'X8' PLYWOOD BACKBOARD IN THE ELECTRIC ROOM FOR NOVAR TO MOUNT
THEIR EQUIPMENT. PHONE AND ETHERNET JACKS FOR THE NOVAR SAVVY CONTROLLER WILL ALSO BE LOCATED ON THIS BOARD BY A SEPARATE TJX VENDOR.
2. MECHANICAL CONTRACTOR A. HORIZONTALLY MOUNT A 2X4 J-BOX WITH CONDUIT (WIREMOLD IF EXPOSED IN FINISHED AREAS) AT THE
LOCATIONS DESIGNATED ON THE NOVAR CONTROLS SITE SPECIFIC PLANS. THE J-BOXES ARE TO BE MOUNTED AT 60" A.F.F. EXCEPT IN FITTING ROOM LOCATIONS WHERE THE J-BOXES ARE TO BE MOUNTED AT 84" A.F.F.. ON THE SALES FLOOR, THE J-BOXES ARE TO BE MOUNTED ON BACK SIDE OF THE COLUMNS WHEN VIEWED FROM FRONT OF STORE.
B. PROVIDE AND INSTALL A PERMANENT STRANDED 18/8 AWG NON SHIELDED CABLE (18/10 IF THE RTU IS EQUIPPED WITH A C02 SENSOR WITH THE UNIT) FROM EACH ROOFTOP UNIT TO THE NOVAR ETM (T- STAT) LOCATION SHOWN ON THE NOVAR PLAN THAT SUPERSEDES ANY MECHANICAL PLAN LOCATIONS.
C. TEMPORARY THERMOSTATS ARE TO BE INSTALLED AT THE ETM LOCATIONS AND THE ROOFTOP UNITS STARTED.
D. HVAC EQUIPMENT ARE TO HAVE HAD A MANUFACTURER'S RECOMMENDED STARTUP PROCEDURE PERFORMED AND BE OPERATIONAL IN ALL MODES BEFORE THE ARRIVAL OF THE NOVAR CONTROLS REPRESENTATIVE FOR THE FINAL NOVAR INSTALLATION.
3. ELECTRICAL CONTRACTOR A. PROVIDE AND INSTALL A THREE PHASE CIRCUIT BREAKER (20 AMPS) FOR THE PHASE MONITOR. THIS
BREAKER MAY BE INSTALLED IN A LIGHTING DISTRIBUTION PANEL IF THE PANEL IS OF THE SAME VOLTAGE AS THE MAIN DISTRIBUTION PANEL.
B. INSTALL THE NOVAR PROVIDED CURRENT TRANSFORMERS (CTS). C. CONNECT ALL CT WIRING TO THE PHASE MONITOR. D. MOUNT AND POWER THE PHASE MONITOR. E. PROVIDE AND INSTALL BMS#1 (20 AMP, 1 POLE BREAKER), BMS#2 (20 AMP, 1 POLE BREAKER), AND BMS #
3 (20 AMP, 1 POLE BREAKER) POWER SUPPLY. THESE BREAKERS MUST ORIGINATE FROM THE SAME PHASE.
F. THE INSTALLATION, PROGRAMMING, AND LABELING OF THE GE SOFTWIRE PANEL IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.
HVAC SUMMARY (REFER TO TJX SPECIFICATIONS FOR DETAIL INFORMATION)
1. HVAC NOVAR INTERFACE (THE HVAC CONTRACTOR'S WORK PRIOR TO THE NOVAR CONTRACTOR'S WORK): A. THERMOSTATS:
a. THE HVAC CONTRACTOR IS TO PROVIDE AND INSTALL A PERMANENT 18/8 (18/10 IF THE RTU IS EQUIPPED WITH A CO2 SENSOR WITH THE UNIT) THERMOSTAT WIRING FROM THE LOW VOLTAGE SECTION OF EACH HVAC UNIT TO THE FINAL LOCATION OF THE THERMOSTAT (LOCATION OF THE THERMOSTATS ARE IN ACCORDANCE WITH THE PLANS PRODUCED BY NOVAR AND SUPERSEDE THE MECHANICAL PRINT LOCATIONS).
b. THE HVAC CONTRACTOR IS TO INSTALL A TEMPORARY THERMOSTAT FOR EACH HVAC UNIT AT THESE LOCATIONS
c. FOR TESTING AND OPERATIONS. d. THE THERMOSTATS ARE TO BE MOUNTED AT 60" A.F.F. EXCEPT IN THE FITTING ROOM WHERE THE
THERMOSTAT IS TO e. BE MOUNTED AT 84" A.F.F.. IF THERMOSTAT LOCATIONS CONFLICTS WITH A PHONE LOCATION,
INSTALL THERMOSTAT f. SIX TO EIGHT INCHES ABOVE THE PHONE. IF PROVIDED, CO2 SENSORS ARE TO BE INSTALLED SIX
INCHES g. DIRECTLY ABOVE THE THERMOSTAT. h. IN COLD WEATHER, THE HVAC CONTRACTOR IS TO PROVIDE AND INSTALL TEMPORARY A
THERMOSTAT FOR RECEIVING HEATERS. B. SMOKE DETECTORS:
a. THE HVAC CONTRACTOR IS TO SUPPLY AND INSTALL SMOKE DETECTORS FOR THE HVAC EQUIPMENT, (AS WELL AS ANY ADDITIONAL DETECTORS REQUIRED BY THE BUILDING AND FIRE OFFICIALS HAVING JURISDICTION AND GOVERNING CODE). THE SMOKE DETECTORS ARE TO BE PHOTOELECTRIC.
2. AIR BALANCING: A. UPON COMPLETION OF THE HVAC SYSTEM, AIR BALANCING IS TO BE PERFORMED BY AN INDEPENDENT
CERTIFIED AIR BALANCING COMPANY. a. THE CERTIFIED AIR BALANCING REPORT IS TO BE SUBMITTED TO THE TJX COMPANIES PROJECT
MANAGER. B. THE DISPOSABLE HVAC FILTERS ARE TO BE CHANGED JUST PRIOR TO THE STORE GRAND OPENING. C. ALL ABANDONED HVAC EQUIPMENT IS TO BE PROPERLY REMOVED AND DISPOSED. D. THE SPACE ABOVE THE CEILING IS NOT TO BE USED AS A RETURN AIR PLENUM. E. ALL EQUIPMENT AND CONTROL DEVICES ARE TO BE APPROPRIATELY IDENTIFIED AND PERMANENTLY
ATTACHED. 3. BASEBOARD HEATERS
A. BASEBOARD HEATERS ARE TO BE FACTORY EQUIPPED WITH INTEGRAL THERMOSTATS AND ARE TO BE INSTALLED IN ALL OFFICES, LOUNGE, RESTROOMS, AND SECURITY OFFICES THAT HAVE AT LEAST ONE OUTSIDE WALL (IN CLIMATE ZONES 4 AND 5).
B. THE CIRCUITING FOR BASEBOARD HEATING IS TO BE THROUGH THE GE RELAY PANEL. 4. VESTIBULE HEATERS
A. ELECTRIC VESTIBULE HEATERS ARE TO BE FACTORY EQUIPPED WITH LOW VOLTAGE CONTROLS, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: POWER CONTRACTORS, LOW VOLTAGE TRANSFORMER AND A TWO WIRE FIELD TERMINATION CONTROL POINT.
5. EXHAUST FANS. EXHAUST FANS ARE TO BE CONTROLLED AS SHOWN ON TJX CRITERIA PLANS AND POWERED VIA EMPLOYEE LIGHT CONTRACTOR ON THE GE SOFTWIRE CONTRACTOR PANEL.
LIGHTING SUMMARY (REFER TO TJX SPECIFICATIONS FOR DETAIL INFORMATION)
1. NIGHT LIGHTING: A. NIGHT LIGHTS ARE TO BE ON 24 HOURS A DAY AND ONLY IN THE SALES AREA.
a. THE CIRCUIT FOR NIGHT LIGHTING IS NOT TO BE CONNECTED TO THE GE RELAY PANEL, OR EMERGENCY LIGHTING. THE NL SHOULD BE ONLY (1) CIRCUIT IN MOST SITUATIONS.
B. NIGHT LIGHTING "RULE OF THUMB" IS (1) NIGHT LIGHT FOR EVERY 3,500 SQUARE FEET OF SALES AREA (ROUND UP), AND SHOULD BE EVENLY DISTRIBUTED. (REFER TO TJX CRITERIA PLAN SHEET (C5) FOR EXACT QUANTITIES & LOCATIONS).
2. EMERGENCY LIGHTING: A. EMERGENCY LIGHTING IS TO BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES AND AT THE
DIRECTION OF THE GOVERNING AUTHORITIES. B. AT A MINIMUM, THE EMERGENCY LIGHTING IS TO BE AS FOLLOWS:
a. ALL ROOMS AND SPACES ARE TO HAVE AT LEAST (1) EMERGENCY LIGHT. b. THE SALES AREA IS TO HAVE (1) EMERGENCY LIGHT PER 2,000 SQUARE FEET OF FLOOR AREA, AND
SHOULD BE EVENLY DISTRIBUTED THROUGHOUT THE SPACE. PATHS OF EGRESS SHOULD BE OF PRIMARY COVERAGE.
c. THE STOCK ROOM SHOULD HAVE A MINIMUM OF (4) EMERGENCY LIGHTS. C. THE EMERGENCY LIGHTING SYSTEM AND CIRCUITS ARE NOT TO BE CONNECTED TO THE GE RELAY
PANEL AND THE CIRCUITS ARE TO BE DEDICATED WITH BREAKER LOCKS INSTALLED AT THE PANEL. D. THE EMERGENCY LIGHTS ARE TO BE LITHONIA LIGHTING, MODEL #ELM2, SELF CONTAINED BATTERY
UNITS. 3. SECURITY LIGHTING:
A. EXTERIOR SECURITY LIGHTING INCLUDES EXTERIOR WALL LIGHT PACKS ATTACHED TO THE BUILDING AS NOTED ON THE PLANS. THESE ARE GENERALLY MOUNTED ABOVE ALL EGRESS DOORS FROM THE STORE.
B. THE CIRCUITING FOR THIS IS THROUGH THE GE RELAY PANEL. C. NOVAR WILL CONTROL THIS LIGHTING BY A SEPARATE CHANNEL IN THE RELAY PANEL. THIS LIGHTING IS
OVERRIDDEN BY A LIGHT SENSOR SUPPLIED AND INSTALLED BY NOVAR. 4. SIGNS AND CANOPY LIGHTS:
A. THIS INCLUDES THE BUILDING, MALL, LIGHTED UNDER CANOPY, ETC. SIGNS AS WELL AS ANY CANOPY LIGHTS (IF NOT BEING CONTROLLED BY THE LANDLORD'S HOUSE PANEL).
B. THESE CIRCUITS ARE TO BE RUN THROUGH THE GE RELAY PANEL. C. NOVAR WILL CONTROL THESE CIRCUITS BY A SEPARATE CHANNEL IN THE RELAY PANEL.
5. CUSTOMER LIGHTING: A. SALES AREA:
a. ONE HALF OF THE SALES AREA CEILING LIGHTS (ALTERNATE ROWS). b. ALL PERIMETER LIGHTING. c. ALL PENDANT LIGHTING. d. JEWELRY COUNTER LIGHTING. e. LAMP DEPARTMENT PLUGMOLD (ON WALLS AND FLOOR GONDOLAS). f. FLOOR OUTLETS FOR LAMP DEPARTMENT. g. CEILING MOUNTED CHANDELIER FIXTURE OUTLETS. h. ANY SPECIALTY LIGHTING (I.E. WALL SCONCES, ETC.).
B. OFF SALES AREA: a. PENDANT LIGHTS IN THE FITTING ROOM b. LIGHTED MIRRORS IN THE FITTING ROOM
C. THESE CIRCUITS ARE TO BE RUN THROUGH THE GE RELAY PANEL. 6. EMPLOYEE LIGHTING:
A. EMPLOYEE LIGHTING IS TO INCLUDE ALL (EXCEPT AS EXCLUDED BELOW) INTERIOR STORE LIGHTING AND BE RUN THROUGH THE GE RELAY PANEL. THE SALES AREA CEILING LIGHTS IS TO BE ALTERNATE ROWS.
B. ITEMS NOT INCLUDED IN "EMPLOYEE LIGHTING" ARE NIGHT LIGHTING, EMERGENCY LIGHTING, EXIT LIGHTING, DOCK LIGHTS, "SECURITY LIGHTING", "SIGNS AND CANOPY LIGHTS", AND "CUSTOMER LIGHTING" AS DESCRIBED ABOVE.
C. EMPLOYEE LIGHTING IS TO INCLUDE ALL EXHAUST FANS EXCEPT THE ELECTRICAL ROOM EXHAUST FAN THAT IS TO BE CONTROLLED BY A STAND-ALONE LINE VOLTAGE THERMOSTAT (SET AT 80° F). THESE CIRCUITS ARE TO BE RUN THROUGH THE GE RELAY PANEL.
7. G.E. SOFTWIRE RELAY PANEL PROGRAMMING: A. SOFTWIRING LIGHTING GROUPS
a. THE SCM SHALL ALLOW ANY GROUP OF RELAYS WITHIN THE PANEL TO BE ASSOCIATED ("SOFTWIRED") TO A CHANNEL USING THE FOLLOWING PROCEDURE: • ...PRESS AND HOLD THE CHANNEL PUSH BUTTON FOR SEVERAL SECONDS. THE CHANNEL LED AND
THE LEDS FOR RELAYS CURRENTLY CONTROLLED BY THAT INPUT WILL BEGIN TO FLASH. • ...SELECT THE RELAYS TO BE CONTROLLED. THE LED FOR EACH RELAY "SOFTWIRED" TO THE
CHANNEL SELECTED WILL BE FLASHING ON/OFF. PRESS THE ASSOCIATED RELAY CONTROL BUTTON TO ADD/DELETE THAT RELAY TO/FROM GROUP.
• ...PRESS THE CHANNEL PUSH BUTTON AGAIN. THE LEDS WILL STOP FLASHING AND THE CHANNEL PUSH BUTTON AND ASSOCIATED SWITCH INPUTS WILL NOW CONTROL THE RELAYS SELECTED.
b. TURNING A CHANNEL ON/OFF WILL SEQUENCE ALL OF THE RELAYS WITHIN THAT GROUP ON/OFF INDIVIDUALLY.
B. CONTROLLING A SOFTWIRE GROUP a. EACH CHANNEL SHALL HAVE AN ASSOCIATED PUSH-BUTTON WITHIN THE PANEL TO TOGGLE THE
CHANNEL ON/OFF b. EACH CHANNEL SHALL ALSO HAVE TWO SEPARATE SWITCH OR DRY CONTACT INPUTS THAT WILL
ALLOW THE CHANNEL TO BE CONTROLLED REMOTELY. c. THE CHANNEL SHALL RESPOND TO THE LAST INPUT. d. THE UNIT SHALL ALLOW A "MASTER CHANNEL" TO BE CONFIGURED TO CONTROL SEVERAL OF THE
ABOVE CHANNELS BY SIMPLY INCLUDING ALL OF THE RELAYS OF THESE "SUB CHANNELS" WITHIN THE MASTER.
C. GROUP STATUS a. EACH CHANNEL PUSH-BUTTON SHALL INCLUDE A LED STATUS INDICATION. THE LED WILL BE ON
WHENEVER ALL OF THE RELAYS WITHIN THE CHANNEL GROUP ARE ON; AND SHALL GO OFF WHEN ALL OF THE RELAYS WITHIN THE GROUP GO OFF.
b. EACH CHANNEL SHALL ALSO HAVE AN ASSOCIATE DRY CONTACT CLOSURE OF PILOT CONTACT WHICH TRACKS THE LED OPERATION DESCRIBED ABOVE.
D. CONTROLLING AN INDIVIDUAL RELAY a. EACH RELAY SHALL HAVE AN ASSOCIATED CONTROL BUTTON WITH LED STATUS INDICATION
MOUNTED WITHIN THE LOW VOLTAGE SECTION OF THE PANEL.
FINISHED FLOOR
CP-1
MPS
NOTE: SUB-CONTRACTOR TO FURNISH AND INSTALL 3, 120V DEDICATED CONTROL CIRCUITS. BMS #1, BMS #2 & BMS #3. THESE CIRCUITS SHALL BE SOURCED FROM PANEL "CP".
NOVAR SYSTEM REQUIRES (1) 20A/3P CIRCUIT BREAKER AT MDP FOR PHASE MONITOR.PHONE LINE
FROM BUILDING PHONE SYSTEM.
TELEPHONE/SECURITY EQUIPMENT
SAME DEIDCATED CIRCUIT
ALARM SYSTEM ENCLOSURE
ALARM SYSTEM CONTROL PANEL
ALARM SYSTEM CONTROL PANEL
ALARM SYSTEM POWER SUPPLY
1
2 "
COUNTER SUPPORT (TO BE MOUNTED DIRECTLY NEXT TO THE WALL OR 30 INCHES FROM THE WALL.)
ACOUSTICAL CEILING TILE
TABLE/DESK COUNTER
110V, 24HR PLUG MOLD STRIP MOUNTED CENTRALLY ON WALL ABOVE DESKTOP, APPROX. 41" AFF ON BREAKER LOCK, DEDICATED CIRCUITS AS REQUIRED.
EQ EQ
MC-4 DPS
2 COND
NOTES: (1) ALL LOW VOLTAGE SIGNAL WIRING SHALL BE 20-GAUGE MINIMUM. THE MINIMUM INDUCTIVE LOAD (LOCK) POWER WIRE GAUGE SHALL BE DETERMINED PER THE SDC WIRE GAUGE CHART. ALL WIRING (SINGLE OR MULTI- CONDUCTOR) SHALL BE COLOR CODED WITHOUT SPLICES. A MINIMUM OF TWO SPARE CONDUCTORS IS RECOMMENDED. (2) SPECIFY VOLTAGE WHEN ORDERING PRODUCTS. VOLTAGE IS NOT SPECIFIED ON THIS WIRE DIAGRAM. BE SURE ALL PRODUCTS ARE VOLTAGE COMPATIBLE. (3) ALL WIRING MUST CONFORM TO NATIONAL, STATE AND LOCAL CODES. (4) ALWAYS CONSULT WITH THE AUTHORITY HAVING JURISDICTION (AHJ) BEFORE INSTALLATION. (5) WHERE REQUIRED BY CODE.
COMPONENTS:
QTY DESCRIPTION PART NUMBER MANUFACTURER 2 ELECTRIC STRIKE 45-4S U SDC 1 POWER SUPPLY W/DUAL INTERLOCK CIRCUIT BOARD 631RFA X UR2A SDC 2 MOMENTARY SPDT - PUSH BUTTON SWITCHES 15-2 X SPDT X MOM SDC 2 MAGNETIC DPS SWITCHES MC-4 SDC
METHOD OF OPERATION THE ABOVE LAYOUT IS IDENTIFIED AS A MANTRAP "B". BOTH OPENINGS HAVE MECHANICAL LOCKS THAT ARE LATCHED & UNLATCHED BY ELECTRIC STRIKES. ACCESS / EGRESS: ENTERING IS ACCOMPLISHED BY EITHER MECHANICAL KEY OR PUSH BUTTON CONTROL FROM INSIDE A CASH ROOM. EGRESS IS FREE AT ALL TIMES.
A5 A6 A7 A8 A9 A10 B5 B6 B7 B8 B9B10
STATION A OUTPUT
STATION B OUTPUT
Y
E1 E2 E3 E4 E5 E7 E8E6A1 A2 A3 A4 B4B2 B3B1 STATION A OUTPUT
STATION B OUTPUT
DIP SWITCH 1 2 3 4 5 6 7 8
ON
24 VDC OUTPUT
45-4S U ELECTRIC STRIKE
ITEM
NOTE: REFER TO TJX DRAWING C6 POWER PLAN FOR EXACT QUANTITY & LOCATION OF ALL DEDICATED / ISOLATED GROUND RECEPTACLES SHOWN IN THE DIAGRAM BELOW.
SINGLE QUE REGISTERS
QUADRUPLEX RECEPTACLE 15A, 125 VOLT, WITH ISOLATED GROUND.
PANEL "CP" 120/208V 1P 3W WITH NEUTRAL & ISOLATED GROUND GE 20 CIRCUIT WITH 2 POLE 30AMP MAIN C.B. BOLTON TYPE 20 IP - 20AMP C.B.
DOUBLE GANG BOX WITH BRUSHED ALUMINUM COVER PLATE T0 SUIT RECEPTACLE
DUPLEX RECEPTACLE 20A, 125 VOLT WITH ISOLATED GROUND
P.O.S. CASH REGISTER 120 VOLT WIRING
WIRING RUN THROUGH CONDUIT COORDINATE
WITH C6 SHEET
1/2" FLEXIBLE CONDUIT WITH APPROPRIATE WATERTIGHT
CONNECTOR
1/2" -3 NO. 10 TO POWER POLE J.B. (IF APPLICABLE)
SUSP. CEILING
SYSTEMS ROOM
NOT TO SCALE
3/4" -1 NO. 8 CONNECT DIRECTLY TO MAIN SERVICE GROUND
POWER PANEL
(IF APPLICABLE)
ALUM. POWER POLE WIREMOLD # NP600C ANCHOR AT CLG. & COUNTER TOP. (IF APPLICABLE)
REGISTERS
NOTES: 1. TJX SHALL BRING IN AN OUTSIDE
CONTRACTOR TO SUPPLY, RUN AND TERMINATE THE LOW VOLTAGE COMMUNICATION WIRING. THIS INCLUDES THE LOW VOLTAGE WIRING FOR REGISTERS POS AS WELL AS THE CABLE FOR THE TIME CLOCK, ACS AND MANAGERS OFFICE TO LAYAWAY CABLES.
2. CABLES TO BE RUN IN ONE PIECE FROM REGISTER TO REGISTER
3. ALL LOW VOLTAGE WIRING TO BE INSTALLED ABOVE HUNG CLG. AND SHALL BE KEPT A MINIMUM OF 5'-0" FROM FLUORESCENT LIGHTING FIXTURES
4. CONTRACTOR IS RESPONSIBLE FOR CONDUIT AND PULL STRINGS.
NOTES: 1. EXACT NUMBER AND FINAL LOCATIONS OF ALL ITEMS SHOWN
INCLUDING EXACT METHOD OF INSTALLING CONDUIT & WIRE SHALL BE DETERMINED IN THE FIELD WITH TJX REPRESENTATIVE.
2. ALL WIRING SHALL BE TYPE "THW" OR "THHN" COPPER RUN IN CONDUIT.
3. PROVIDE A SEPARATE NEUTRAL AND GROUND CONDUCTOR FOR EACH 120 VOLT CIRCUIT PROVIDED FROM PANEL "CP" PANEL "CP" SHALL BE USED TO SUPPLY ONLY REGISTER EQUIP.
4. ALL GROUND CONNECTORS SHALL BE ISOLATED (PURE- GROUND ONLY) AND SHALL NOT BE GROUNDED TO ANY METAL ENCLOLSURES.
5. THE ELECTRICAL CONTRACTOR SHALL LABEL ALL PANELS, RECEPTACLES, SWITCHES, ETC., TO IDENTIFY VOLTAGES AND FUNCTION.
6. PROVIDE RED NAMEPLATE STENCIL AS FOLLOWS: "FOR COMPUTER EQUIPMENT ONLY - NOT FOR GENERAL USE"
NOTES: CONVENIENCE OUTLETS AT SERVICE DESK SHALL NOT BE CONNECTED TO THE CP APNE.
P.O.S. A.C. WIRING TEST FOR INSULATED-ISOLATED GROUND
TO TEST DISCONNECT I.G. GROUND AT MAIN ENTRANCE AND CHECK ALL OUTLETS FROM:
GROUND TO BOX -------------NO CONTINUITY GROUND TO NEUTRAL ----- NO CONTINUITY- NO VOLTAGE GROUND TO HOT -----------NO VOLTATE
WITH I.G. GROUND HOOKED BACK UP AT MAIN PANEL I.G. GROUND TO BE TAGGED OR LABELED AT MAIN ENTRANCE.
GROUND TO BOX -------------NO CONTINUITY GROUND TO NEUTRAL ----- NO CONTINUITY- NO VOLTAGE GROUND TO HOT -----------120 VOLTS
REG 01
UPS UNIT SUPPLIED BY TJX COMPANIES INSTALLED BY GENERAL CONTRACTOR'S ELECTRICIAN.
*** ALL DELIVERY QUESTIONS SHOULD *** BE DIRECTED TO TJX SYSTEMS
IMPLEMENTATION AT 508-475-8105
UPS
CIRCUITS TO FEED, ISOLATED GROUNDED RECEPTACLES
AND ALL REGISTER LOCATIONS.
NOTES:
1. VERTIV RECOMMENDED WIRE SIZE, INCLUDING GROUND WIRE, @ 75° COPPER WIRE IS 10AWG (4mm). MAXIMUM WIRE ACCEPTED BY TERMINAL BLOCK IS 8AWG (6mm).
2. VERTIV RECOMMENDS INSTALLING A UL489 APPROVED BREAKER UPSTREAM OF UNIT.
3. THE INSTALLER MUST PROVIDE CIRCUIT BREAKER PROTECTION ACCORDING TO LOCAL CODES. THE UTILITY DISCONNECT SHOULD BE WITHIN SIGHT OF THE UPS OR HAVE AN APPROPRIATE LOCK OUT. MAINTAIN SERVICE SPACE AROUND THE UPS OR USE FLEXIBLE CONDUIT.
4. THE INSTALLER MUST PROVIDE OUTPUT DISTRIBUTION PANELS, CIRCUIT BREAKER PROTECTION, OR EMERGENCY DISCONNECTS ACCORDING TO LOCAL CODES.
5. OUTPUT CIRCUITS MUST NOT SHARE A COMMON.
6. CP PANEL WILL SERVICE ALL REGISTER POWER, BLADE SERVER, IDF, AND BMS POWER ONLY. NO OTHER CIRCUIT TO BE FED FROM CP.
A
30 AMP CP PANEL
**
Vertiv GXT5-5000MVRT4UXLN
UPS Installation Guidelines VERTIV CONTACT INFORMATION
VERTIV TECHNICAL SUPPORT PHONE: 800 - 222 - 5877 Option #1 Hardware Support
GENERAL INFORMATION: • GCs or Electrical Contractors are not required to purchase the UPS. • TJX provides all units from a third party location; DO NOT CALL
VERTIV WITH DELIVERY CONCERNS. • The units are a Vertiv GXT5-5000MVRT4UXLN tower UPS - 16.9”
(H) x 6.8” (W) x 26.1” (D) and weigh 132 pounds total. The units arrive in three separate boxes via FEDEX
• Wiring diagram is included on the TJX criteria, sheet C7. • Installation does NOT require Vertivto be onsite.
INSTALLATION: Electrical Contractor responsibilities: • Unpack/set/place the UPS, placement must conform to local and
national codes. • UPS ships in three boxes, UPS, Internal Battery pack and SNMP
card. Please refer to the UPS Manual, ships with the unit, for proper installation. Starts on Page 12.
• Terminate wiring at input and output of UPS. • Ensure distribution wiring, CP Panel, and disconnect are correctly
installed.
START UP Electrical Contractor responsibilities: • Unit must be turned on and taken out of BYPASS after installation is
complete. • Confirm the UPS is the only source feeding the CP Panel • Call Vertiv at the above number to troubleshoot any issues with
Start up • Provide support for Vertivif wiring issues arise during Start Up. • After UPS is Turned on and taken out of BYPASS without any
issues, the TJX PM must be notified that UPS installation is complete and the UPS is functional without issues.
A. FURNISH AND INSTALL A REAR DOOR ALARM CONTROL SYSTEM AT THE STOCK ROOM DOOR TO THE EXTERIOR (3'-0" X 6'-8"). PROVIDE 120 VOLT CIRCUIT (UNSWITCHED) AND A LOW VOLTAGE TRANSFORMER (24V/50 VA) U.L. APPROVED, ABOVE THE HEAD OF THE DOOR (WITHIN 10'-0"). ALARM SHALL BE ACTIVATED BY DOOR CONTACTORS WHEN DOOR IS OPEN POSITION AND SHALL PRODUCE A CONTINUOUS CHIME TONE.
B. DOOR ALARM SYSTEM SHALL BE WHEELOCK 38GV29 FROM GRAINGER INDUSTRIES MODEL #CH121092 WITH WEATHERPROOF PUSH BUTTON.
REAR DOOR ALARM CONTROL
BLACK: 120V
WHITE: NEUTRAL
NOTE: UNUSED LEAD MUST BE PROPERLY INSULATED WITH WIRENUT OR OTHER APPROVED METHOD.
CHARGER BOARD
BATTERY CONNECTOR
(SINGLE POLE)
INTR48-N48-GB00
CAT5 - CAN BUS
7 X AWG#18 - 6 ZONES CONTROLS USE ONE WIRE FOR EACH ZONE PLUS ONE COMMON
TO LOAD 120/277 V
THE SAME CIRCUIT THROUGHOUT CASH
REGISTER AREA. (TYP.)
QUAD I.G.
SINGLE DEDICATED OUTLET TO FACE OUTWARD AND BE MOUNTED BELOW THE DRAWER AND ABOVE THE ACCESS PANEL.
SINGLE DEDICATED OUTLET TO FACE OUTWARD AND BE MOUNTED BELOW THE DRAWER AND ABOVE THE ACCESS PANEL.
ACCESS PANEL WITH 1/4" COVER TYP. BOTH ENDS
RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON THE SAME CIRCUIT THROUGHOUT CASH REGISTER AREA. (TYP.)
RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON
THE SAME CIRCUIT THROUGHOUT CASH
REGISTER AREA. (TYP.)
ACCESS PANEL WITH 1/4" COVER TYP. BOTH ENDS
RECEPTACLES FOR "EAS" SECURITY TO BE LOCATED ON THE SAME CIRCUIT THROUGHOUT CASH REGISTER AREA. (TYP.)
SINGLE DEDICATED OUTLET TO FACE OUTWARD AND BE MOUNTED BELOW THE DRAWER AND ABOVE THE ACCESS PANEL.
NOT TO SCALEC7 1
NOT TO SCALEC7 2 TYPICAL DETAIL @ L.P. OFFICE
NOT TO SCALEC7 4
NOT TO SCALEC7 5
NOT TO SCALEC7 6
NOT TO SCALE
SINGLE Q CHECK OUT STAND ELEVATION 'A' @ END CHECK OUT (TYPICAL)
Scale
Date
Store Number
Planned By
Deal Type
As indicated
C7 EL
03/11/21 KTL
JR/DEM
SINGLE Q CHECK OUT STAND ELEVATION 'A' @ CHECK OUT (TYPICAL)
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
SHOE TABLE
PALLET STAGING
HANGER RACK
6 5 4
4 STORAGE56 U
T.D. T.D. T.D.
120" AFF
53 " P
NL M
IR RO
R 53
" P NL
M IR
RO R
FOCAL WALL SAVING NEVER LOOKED SO GOOD
FO CA
L W
AL L
LO VE
T HE
L AB
EL A
ND T
HE P
RI CE
FO CA
L W
AL L
BR AN
D NA
M ES
F OR
L ES
S S S S S S S S S S
B B
P
NESTAFLEX
NESTAFLEX
8' -
10' 10' 10'
A
NOTE: REFER TO DOOR AND HARDWARE SCHEDULE ON DRAWING C2 FOR ALL ADA EXIT SIGN TYPES AND LOCATIONS.
1
2
3
4
5
EL EC
TR IC
Store Number
Planned By
Deal Type
1/8" = 1'-0"
C8 EL
03/11/21 KTL
FIXTURE PLAN
NEWPORT, TN
JR/DEM
First Level Sales 84% 16,274.2 SF Supports 16% 3,182.4 SF
NO. DESCRIPTION DATE 1 ADDED M1 TO CRITERIA SET 6/25/21
Sheets
C4 - INTERIOR ELEVATIONS
C8 - FIXTURE PLAN