WEIGHT AND DIMENSION 24 Kg : 350 mm : 167 mm : 180 mm : 183 mm COVER AND CONTAINER : A.B.S. UL94-HB, UL94-V0 Optional. : NSAP 12-80 Ah : F11/F15 OTHER -20°C to 60°C Discharge 0°C to 50°C Charge -20°C to 60°C Storage PT. NIPRESS Tbk Jl. Raya Narogong Km. 26 16710 Klapanunggal - Bogor TECHNICAL SHEET Battery Weight Length NSAP 12-80 Ah is a top terminal battery with AGM technology is specially designed for Telecom use with over 10 years design life at 25 °C. NSAP type also comply with IEC 60896-21/22, standard battery for telecommunication. The adoption of centralized venting system make sure the battery can be installed in any location and guarantees high security and reliability. DIMENSIONS Terminal Operating Temperature Range Self Discharge : NSAP batteries can be stored for more than 6 months batteries before using : 5.5 mΩ (at 1KHz) Recommended Maximum Charging Current Limit at 25°C. Self-discharge ratio PERFORMANCE TERMINAL SIZE VIEW NSAP 12-80 Width Container Height Total Height : Approximate Material Type : 24 A : 14.6 to 14.8 VDC/unit@25°C Nominal Voltage Max Discharge Current Internal Resistance : 12 V : 80 Ah : 800 A (5 sec) less than 3% per month at 25°C. Please charge Capacity 10 h (C 10 ) Float charging Voltage Equalization and Cycle Service Normal Operating Temp. Range : 25°C±5°C : 13.6 to 13.8 VDC/unit@25°C 5 M6 Ø14 20 7.5 18 8 Ø8.5 167 350 180 183

Upload: others

Post on 02-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: NSAP 12-80 - Nipress · NSAP 12-80 Ah is a top terminal battery with AGM technology is specially designed for Telecom use with over 10 years design life at 25 °C. NSAP type also

 

   

WEIGHT AND DIMENSION24 Kg

: 350 mm: 167 mm: 180 mm: 183 mm

COVER AND CONTAINER: A.B.S. UL94-HB, UL94-V0 Optional.: NSAP 12-80 Ah: F11/F15

OTHER-20°C to 60°C Discharge0°C to 50°C Charge-20°C to 60°C Storage

PT. NIPRESS TbkJl. Raya Narogong Km. 2616710 Klapanunggal - Bogor

TECHNICAL  SHEET

Battery WeightLength

NSAP 12-80 Ah is a top terminal battery with AGM technology is specially designed for Telecom use with over 10 years design life at 25 °C. NSAP type also comply with IEC 60896-21/22, standard battery for telecommunication. The adoption of centralized venting system make sure the battery can be installed in any location and guarantees high security and reliability.

DIMENSIONS

Terminal

Operating Temperature

Range

Self Discharge

: NSAP batteries can be stored for more than 6 months

batteries before using

: 5.5 mΩ (at 1KHz)

Recommended Maximum Charging Current Limit

at 25°C. Self-discharge ratio

PERFORMANCE

TERMINAL SIZE

VIEW

NSAP 12-80

WidthContainer Height

Total Height

: Approximate

Material

Type

: 24 A

: 14.6 to 14.8 VDC/unit@25°C

Nominal Voltage

Max Discharge CurrentInternal Resistance

: 12 V: 80 Ah: 800 A (5 sec)

less than 3% per month at 25°C. Please charge

Capacity 10 h (C10)

Float charging Voltage

Equalization and Cycle Service

Normal Operating Temp. Range : 25°C±5°C: 13.6 to 13.8 VDC/unit@25°C

5

M6Ø14

20

7.518

8

Ø8.5

167350

180 183

Page 2: NSAP 12-80 - Nipress · NSAP 12-80 Ah is a top terminal battery with AGM technology is specially designed for Telecom use with over 10 years design life at 25 °C. NSAP type also

Constan Current Discharge (Amperes) at 25 °C5 min 10 min 15 min 30 mim 1 h 2 h 3h 4 h 5 h 8 h 10 h 20 h182.70 142.40 116.80 70.68 46.41 28.08 19.57 15.46 13.53 8.93 7.91 3.95213.90 159.30 130.20 73.47 47.53 29.26 19.96 15.96 13.62 9.00 8.01 4.12237.00 174.70 141.20 75.98 48.20 29.50 20.20 16.24 13.69 9.04 8.08 4.16264.00 189.30 148.30 78.14 48.80 29.89 20.38 16.49 13.81 9.12 8.16 4.24272.00 196.20 150.70 79.35 49.27 30.21 20.56 16.65 13.90 9.20 8.24 4.32280.10 206.20 153.80 80.38 49.93 30.83 20.95 16.89 14.02 9.24 8.32 4.41

Constant Power Discharge (Watt/cell) at 25 °C5 min 10 min 15 min 30 mim 1 h 2 h 3h 4 h 5 h 8 h 10 h 20 h

2086.00 1609.00 1295.00 839.60 550.70 334.20 233.30 185.60 162.80 107.20 95.19 47.972375.00 1779.00 1439.00 863.30 559.10 347.20 237.30 188.30 163.40 108.00 96.24 49.752607.00 1930.00 1556.00 884.20 566.30 349.80 240.00 194.80 164.20 108.40 97.20 50.232864.00 2073.00 1632.00 902.60 570.00 354.30 241.90 197.50 165.50 109.40 98.16 51.202897.00 2129.00 1650.00 910.50 573.40 356.90 243.00 199.40 166.50 110.20 99.04 52.172955.00 2196.00 1677.00 920.10 578.70 361.30 246.70 202.20 168.00 110.60 99.83 53.09

All mentioned values are average values ( Tolerance ± 2 %)

1.60  V/cell

1.65  V/cell1.60  V/cell

F.V/Time1.85  V/cell1.80  V/cell1.75  V/cell1.70  V/cell

F.V/Time1.85  V/cell1.80  V/cell1.75  V/cell1.70  V/cell1.65  V/cell

Storage Characteristic

TECHNICAL  SHEET

Graphic Life Cycle

Charge characteristic curve for cyclic use Discharge Characteristic Curve

Effect of Temperature Temperature Effects in Relation of Battery Capacity

Supplementary charge required(Carry out supplementary charge before use if 100% capacity is requires)

Supplementary charge requiredbefore use.This supplementary charge will help to recover the capacity and should be made as early as possible.

Supplementary charge may oftenfail to recover the capacity.The battery should never be left standing till this state is reached

Supplementary charge and storage guidelines

30℃

Storage Time (months)

20

0

Cap

acity

(%)

40

60

100

80

40℃

10℃

0℃

2 4 6 8 10 12 14 16 18 20 22 24

20℃

0.1CA0.25CA0.6CA

-30 -20 -10 0 10 20 30 40 50 60Temperature (°C)

20

40

60

80

100

120

Cap

acity

(%

)

5000

DOD

(%)

Cycles1000 1500 2000

102030405060708090

100

150

3

5

10

Desig

n Life

(years

)

Temperature (°C)

20 25 30 35 40 45 50

12

4

6789

1112