nuform for non load bearing

50
for Non-Load Bearing Walls

Upload: nuform

Post on 23-Jan-2015

137 views

Category:

Documents


0 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Nuform for non load bearing

for

Non-Load Bearing Walls

Page 2: Nuform for non load bearing

What is CONFORM ? Patented Concrete Forming Technology

(CFT)

Components interconnect together to createa finished concrete wall

Rigid polymer components thatserve as concrete formwork for:– load bearing walls– non-load bearing walls– shear walls– retaining walls – foundation walls

Page 3: Nuform for non load bearing

200 mm -8” wallinsulated

200 mm -8” wall

150 mm -6” wall

CF8i CF8 CF6 CF4100 mm -4” wall

Wall Types

Page 4: Nuform for non load bearing

ConcreteConcrete Service ChannelService Channel

Reinforcing BarReinforcing Bar

Polymer ShellPolymer Shell

CF8iCF8i(200mm-8” Wall-Insulated)(200mm-8” Wall-Insulated) ANATOMY OF A CONFORM

WALL

InsulationInsulation

Page 5: Nuform for non load bearing

Colour Choices

TanTan

WhiteWhite

Page 6: Nuform for non load bearing

Global Clientele

Page 7: Nuform for non load bearing

The CONFORM Advantage

Integrated building technology

Solid concrete technology -“Built tough - built to last!”

Easy to design using our CFD (Conform Design) tool bars for AutoCAD

Unparalleled finishing flexibility

Fast-track construction

Page 8: Nuform for non load bearing

IntegratedBuilding

Technology The CF8i wall assembly has a minimum effective R-value of 22 (RSI 3.82) in cold climates

Maintenance-free walls that will not leak or rot, is resistant to UV degradation and to mold/mildew growth

Effective deterrent to termites and other pests

Since CONFORM is an integrated building system, it incorporates the insulation/air/vapor barrier within the wall envelope

Page 9: Nuform for non load bearing

The only solution that is:

Corrosion Resistant

Durable

Easy to Clean

Requires Minimal Maintenance

Constructs Quickly

Page 10: Nuform for non load bearing

Constructs Quickly

Every Building is custom made in our factory

All components are pre-cut and labeled for easy on site assembly or can be pre-assembled in 8’ sections for easy erection

Less skilled labor required on site

Cleaner overall work site

Occupy your building sooner

Page 11: Nuform for non load bearing

Design ofCONFORM Walls

CONFORM Walls can designed using the following methods:

“Stay-in-place” formwork designed in accordance with ACI 318, Building Code Requirements for Reinforced Concrete (USA)

Design of Concrete Structures (Canada)

Page 12: Nuform for non load bearing

Concrete Specifications

Minimum 20 MPa (3000 psi) – 28 day compressive strength – non freeze/thaw zones

Minimum 25 MPa (3500 psi) – 28 day compressive strength in freeze/thaw zones

Maximum 10 mm ( 3/8") aggregate (p-gravel)

Minimum 115 mm (4 ½") slump

Aggregate does not segregate due to inner webs of wall components

Page 13: Nuform for non load bearing

Core Sample

taken at bottom

of a

32’ High Wall

Page 14: Nuform for non load bearing

Easy to Design

Specialized Toolbar – CFD for AutoCAD

Can quickly draw a layout and automatically generate a 3-D isometric view and elevations

Can easily incorporate openings for doors and windows and/or any special fabrications that may be required

Information from the layout can be exported to a secondary software program to generate a parts list and cost information

Page 15: Nuform for non load bearing

Construction Sequence

Page 16: Nuform for non load bearing

Connection Details

Roof

Mid Girt

Foundation

Page 17: Nuform for non load bearing

Footing &

Structural

Steel

Page 18: Nuform for non load bearing

Connection

at Footing

Page 19: Nuform for non load bearing

Connection

at Mid-Span

Page 20: Nuform for non load bearing

Connection

at Parapet

Page 21: Nuform for non load bearing

Erection of

CONFORM

Pre-Assembled

Panels

Page 22: Nuform for non load bearing

Erection of

CONFORM

Pre-Assembled

Panels

Page 23: Nuform for non load bearing

Expansion Joint

Control Joint

Page 24: Nuform for non load bearing

Bracing at

Man Door

Page 25: Nuform for non load bearing

Bracing at

Loading Door

Page 26: Nuform for non load bearing

Corner

Bracing

Page 27: Nuform for non load bearing

Pouring

of Concrete

Page 28: Nuform for non load bearing

Clean up

Page 29: Nuform for non load bearing

Feature Bands

Page 30: Nuform for non load bearing

Pre-Engineered

Steel

Hockey RinkVaughn, On

Page 31: Nuform for non load bearing

Pre-Engineered

Steel

Page 32: Nuform for non load bearing

Structural

Steel

Page 33: Nuform for non load bearing

Structural

Steel

Page 34: Nuform for non load bearing

Woodbridge,

Ontario

Page 35: Nuform for non load bearing

Woodbridge,

Ontario

Page 36: Nuform for non load bearing

Mississauga,

Ontario

Page 37: Nuform for non load bearing

Mississauga,

Ontario

Page 38: Nuform for non load bearing

Bolton,

Ontario

Page 39: Nuform for non load bearing

Mississauga,

Ontario

Page 40: Nuform for non load bearing

Kitchener,

Ontario

Page 41: Nuform for non load bearing

Brampton,

Ontario

Page 42: Nuform for non load bearing

Retail

Woodbridge,

Ontario

Page 43: Nuform for non load bearing

Richmond Hill,

Ontario

Page 44: Nuform for non load bearing

Richmond Hill,

Ontario

Page 45: Nuform for non load bearing

Markham,

Ontario

Page 46: Nuform for non load bearing

Iowa, U.S.A.

Page 47: Nuform for non load bearing

Curacao,

Netherlands

Antilles

Page 48: Nuform for non load bearing

St. Maarten

Page 49: Nuform for non load bearing

Summary CFD for AutoCAD Design Tools

CONFORM is a proven technology, with national and international building applications

Reduces Installation time

Reduces life cycle maintenance costs (e.g. No painting required)

Superior energy efficiency with an effective R value of 22

Page 50: Nuform for non load bearing

For additional information

visit our website

www.nuformdirect.com

or contact us toll free

1.877.747.WALL(9255)