fttx indoor systems - dl4jz3rbrsfum.cloudfront.netcpsww.com cybershield 12vdc – 50vdc indoor fttx...

4
FTTx SYSTEMS INDOOR

Upload: phungkien

Post on 07-Mar-2018

255 views

Category:

Documents


0 download

TRANSCRIPT

FTTx SYSTEMSINDOOR

[email protected]

CyberShield12VDC – 50VDC Indoor FTTx Backup Power Solutions

Features• Indoor design

• Audible alarm signals

• Microprocessor intelligent

control

• Telemetry interface

• Optional extendable runtime

• Silenceable audible-alarm for

signaling utility power failure

and low battery

The CyberPower CyberShield indoor battery backup series provides cable telephone, wireless local loop (WLL) and fiber to the premise (FTTP) providers with a dependable and cost effective local power supply for customer premise equipment (CPE) during power outages. The CyberShield indoor family provides Multiple Service Operators with a local powering solution that has lower installation costs, lower operational costs and higher quality than competing power technologies.

CyberShield indoor battery backup products supply continuous 12Vdc or 48Vdc (depending on model) to local power network interface devices (NIDs), cable telephone modems, wireless base stations and fiber to the home Optical Network Terminals (ONTs) or integrated access devices.

MODELS CS75A12V3 CS36A12V3-T CS20A-EBP CPLI72D48V

AC INPUT

Input Voltage Range 90 – 135 VAC 85 – 135 VAC - 46 – 56 VDC

Frequency  50/60 Hz  50/60 Hz - -

Input Power Cord IEC320 C5 3-Prong Cord IEC320 C7 2-Prong Cord - -

Output Ground Reference Floating Ground Floating Ground - -

DC OUTPUT

On Battery Output Voltage 12 VDC with Overvoltage

Protection12 VDC with Overvoltage

Protection- 52 VDC

Rated Power 75 W 36 W - 72 UL

Efficiency (at Full Load) > 75% - - > 80%

BATTERY

Battery Type Sealed, Maintenance Free

Lead-Acid BatterySealed, Maintenance Free

Lead-Acid BatterySealed, Maintenance Free

Lead-Acid BatteryLithium-Ion

Battery Size & Quantity  12V/20Ah x1 12V/8Ah x 1  12V/20Ah x 1 14.4Vdc/2.2Ah x 1

Typical Recharge Time < 24 Hours < 24 Hours - 5 Hours

User Replaceable Yes Yes Yes Yes

SURGE PROTECTION & FILTERING

Lightning / Surge Protection Yes Yes - -

WARNING DIAGNOSTICS

Audible Indicator Utility Failure, Low BatteryUtility Failure, Low Battery,

Replace Battery- -

LED Indicators AC, Output, BatterySystem Status, Battery Power,

Replace Battery, Auxiliary Power Source

- Status, Battery, Fault

MANAGEMENT

Auto-Charge Yes Yes - Yes

Communication Interface On Battery, Replace Battery, Missing Battery, Low Battery

On Battery, Replace Battery, Missing Battery, Low Battery

-On Battery, Replace Battery, Missing Battery, Low Battery

PHYSICAL

Dimensions - L×W×D 30 × 28 × 9.9 cm 17.15 x 17.15 x 8.9 cm 30 × 28 × 9.9 cm 16.5 x 9.6 x 4.7 cm

Weight - with Battery 8.2 kg 3.3 kg 7.5 kg 0.58 kg

ENVIRONMENT

Operating Temperature 32°F – 104°F (0°C – 40°C) -4°F – 122°F (-20°C – 50°C ) 32°F – 104°F (0°C – 40°C ) 23°F – 131°F (-5°C – 55°C)

Operating Humidity 0 – 95% Non-condensing 0 – 95% Non-condensing 0 – 95% Non-condensing 0 – 95% Non-condensing

Max Operating Elevation 10,000 ft (3,000 m) 10,000 ft (3,000 m) 10,000 ft (3,000 m) 10,000 ft. (3,000 m)

Max Storage Elevation 50,000 ft (15,000 m) 50,000 ft. (15,000 m) 50,000 ft (15,000 m) 50,000 ft. (15,000 m)

Storage Temperature 5 – 113 °F (-15 – 45 °C) 5 – 113 °F (-15 – 45 °C) 5 - 113 (-15C - 45C) 23°F – 131°F (-5°C – 55°C)

COMPLIANCE

SystemUL60950-1,

FCC Part 15 Class BFCC Part 15 Class B,

NEBS-

UL60950-1 2nd Edition, FCC Part 15 Class B

cpsww.com*Special conditions may apply. Please contact [email protected] for details.

MODELS CSN27U12V DTC36U12V CS30U12V-20 CS50U48V CS16U48V-8

AC INPUT

Input Voltage Range 90 – 264 VAC 90 – 264 VAC 90 – 264 VAC 90 – 264 VAC 90 – 264 VAC

Frequency 50/60 Hz  50/60 Hz  50/60 Hz 50Hz/60 Hz  50Hz/60 Hz

Input Power CordIEC320 C7 2-Prong Cord or

IEC320 C5 3-Prong CordIEC320 C5 3-Prong Cord IEC320 C7 2-Prong Cord IEC320 C7 2-Prong Cord IEC320 C7 2-Prong Cord

Output Ground Reference Floating or Ground Referenced Grounded Floating Ground Floating Ground Floating Ground

DC OUTPUT

On Battery Output Voltage12Vdc with Overvoltage

Protection12Vdc with Overvoltage

Protection12Vdc with Overvoltage

Protection48Vdc with Overvoltage

Protection48Vdc with Overvoltage

Protection

Rated Power 27 W 36 W 30 W 50 W 16 W

Efficiency (at Full Load)> 80% (Line Mode)  > 90% (DC Mode)

> 80% (Line Mode)  > 90% (DC Mode)

> 75% > 75% > 75%

BATTERY

Battery TypeSealed, Maintenance Free

Lead-Acid BatterySealed, Maintenance Free

Lead-Acid BatterySealed, Maintenance Free

Lead-Acid BatterySealed, Maintenance Free

Lead-Acid BatterySealed, Maintenance Free

Lead-Acid Battery

Battery Size & Quantity 12V/7.2Ah x 1 12V/7.2Ah x 1 12V/20Ah x 1 12V/20Ah x 1 12V/8Ah x 1

Typical Recharge Time 14 Hours (90%) < 24 Hours < 24 Hours (90%) < 24 Hours < 24 Hours

User Replaceable Yes Yes Yes Yes Yes

SURGE PROTECTION & FILTERING

Lightning / Surge ProtectionYes (6kV @ 8/20 us) per IEEE

C62.41.2 and GR-1089Yes (6kV @ 8/20 us) per IEEE

C62.41.2 and GR-1089Yes Yes Yes

WARNING DIAGNOSTICS

Audible Indicator Utility Failure, Low Battery,

Replace BatteryUtility Failure, Low Battery Utility Failure, Low Battery Utility Failure, Low Battery Utility Failure, Low Battery

LED Indicators Battery, Mute, DC,

System StatusBattery, Mute, DC,

System StatusAC, Output, Battery AC, Output, Battery AC, Output, Battery

MANAGEMENT

Auto-Charge Yes – Thermally compensated Yes – Thermally compensated Yes Yes Yes

Communication Interface On Battery, Replace Battery, Missing Battery, Low Battery

On Battery, Replace Battery, Missing Battery, Low Battery

On Battery, Replace Battery, Missing Battery, Low Battery

On Battery, Replace Battery, Missing Battery, Low Battery

On Battery, Replace Battery, Missing Battery, Low Battery

PHYSICAL

Dimensions - L×W×D 16.7 × 19 × 8.3 cm 16.8 x 18.5 x 8.13 cm 30 × 28 × 9.9 cm 30 × 28 × 9.9 cm 16 × 24 × 8.3 cm

Weight - with Battery 3.03 kg 3.13 kg 7.7 kg 7.7 kg 3.3 kg

ENVIRONMENT

Operating Temperature -4°F – 113°F (-20°C – 45°C),

Operation at 50°C (122°F) with de-rating to 18 W

-4°F – 113°F (-20°C – 45°C), Operation at 50°C (122°F) with

de-rating to 30 W32°F – 104°F (0°C – 40°C) 32°F – 104°F (0°C – 40°C) 32°F – 104°F (0°C – 40°C)

Operating Humidity 0 – 95% Non-condensing 0 – 95% Non-condensing 0 – 95% Non-condensing 0 – 95% Non-condensing 0 – 95% Non-condensing

Max Operating Elevation 10,000 ft. (3,000 m) 10,000 ft. (3,000 m) 10,000 ft. (3,000 m) 10,000 ft. (3,000 m) 10,000 ft. (3,000 m)

Max Storage Elevation 50,000 ft. (15,000 m) 50,000 ft. (15,000 m) 50,000 ft. (15,000 m) 50,000 ft. (15,000 m) 50,000 ft. (15,000 m)

Storage Temperature -4° – 113°F (-20°C – 45°C) -4° – 113°F (-20°C – 45°C) 5°F – 113°F (-15°C - 45°C) 5°F – 113°F (-15°C - 45°C) 5°F – 113°F (-15°C - 45°C)

COMPLIANCE

SystemUL60950-1 2nd Edition,

FCC Part 15 Class B, CISPR 22 Class B

UL60950-1 2nd Edition, FCC Part 15 Class B,

CISPR 22 Class B

UL60950-1, FCC Part 15 Class B

UL60950-1, FCC Part 15 Class B,

CISPR 22 Class B

UL60950-1, FCC Part 15 Class B,

CISPR 22 Class B

VARIANTS*

North America (NEMA 1-15)

CSN27U12V-12 CSN27U12V-XL

CSN27U12V-NA2 CSN27U12V-NA3

CSN27U12V-NA3-G

DTC36U12V-NA3-G CS30U12V-20 CS50U48V –

European Schuko (CEE 7)*CSN27U12V-SC2 CSN27U12V-SC3

CSN27U12V-SC3-GDTC36U12V-SC3-G – – –

Australia & New Zealand (AS/NZS)*

CSN27U12V-AZ2 CSN27U12V-AZ3

CSN27U12V-AZ3-GDTC36U12V-AZ3-G CS30U12V-20-AZ2 CS50U48V-AZ2 –

United Kingdom (BS 1363)*CSN27U12V-UK2 CSN27U12V-UK3

CSN27U12V-UK3-GDTC36U12V-UK3-G – – –

Brazil (Type J)*CSN27U12V-BZ3

CSN27U12V-BZ3-GDTC36U12V-BZ3-G – – –

Canada (NEMA 1-15)* – – – CS50U48V-CA –

CPSWW.COM

Cyber Power Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379

© 2016 Cyber Power Systems (USA), Inc. CyberPower is a registered trademark and brand of Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners. CyberPower reserves the right to modify product information or specifications without notice. The information presented is accurate at the time of publication. 05-2016