Poseidon 4002 Rack monitoring 1

Upload: huong

Post on 12-Feb-2016

51 views

Category:

Documents


1 download

DESCRIPTION

Poseidon 4002 Rack monitoring. Poseidon: Monitor & Control. IT environment threats in DC. Poseidon 4002. Poseidon 4001. Based on data from: 1) „ Uptime Institute “ & „ PROGNOSIS - Integrated Research “ for USA during 99 .. 06. 2) American Power Conversion 2006 . - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Poseidon 4002  Rack monitoring

Poseidon 4002 Rack monitoring

1

Page 2: Poseidon 4002  Rack monitoring

Poseidon: Monitor & Control

2

Page 3: Poseidon 4002  Rack monitoring

IT environment threats in DC

Temperature

Humidity

Power

Water leak

Smoke

AirFlow

Entrance security

Based on data from:1) „Uptime Institute“ & „PROGNOSIS - Integrated Research“ for USA during 99 .. 06.2) American Power Conversion 2006

Poseidon 4002

Poseidon 4001

3

Page 4: Poseidon 4002  Rack monitoring

Fast reaction required

Energy consumption (and thus A/C needs) of data center has risen by 48% from 1999 to 2006.

4

For an average data center, the temperature rises from the usual 20°C to 30°C within 8.6 minutes after A/C failure.

Page 5: Poseidon 4002  Rack monitoring

Poseidon 4002: Features

•Web: Built-in web server•Sensors: 4xRJ11 1-Wire UNI (max 12 probes)•Inputs: 6 digital inputs (dry contacts)•Outputs: 2 digital outputs (24VDC relays)•GSM modem: External via RS-232•Mechanical: 1U (10" or 19" cabinet)

5

Page 6: Poseidon 4002  Rack monitoring

Sensors

Four independent active sensor ports for 1-Wire UNI sensors.6

Page 7: Poseidon 4002  Rack monitoring

Monitor your DC power

7

1) Monitor -48V DC voltage of the batteries

2) Monitor DC current 0..80A

600 413 Sensor 60V 1W-uni• Galvanic isolated• 1-Wire UNI sensor

Page 8: Poseidon 4002  Rack monitoring

Feature 1-Wire UNI sensors

8

AC 230V 0..30A probe

Meassure current in separated phase wire

• 8 analog 0..15V• 6 DI for dry contact

Page 9: Poseidon 4002  Rack monitoring

Prevent these situations1) Air Conditioning system failure

2) Power system failures

3) Short-term as well as long-term temperature issues

4) Water leaks A/C units, pipeline, floods

5) Security issues Controlled access to equipment

9

Page 10: Poseidon 4002  Rack monitoring

Poseidon 4002 TsetPoseidon 4002 Tset is recommended starting package for monitoring your 19” rack or cabinet. There are included most popular parts in one package

600 384 Poseidon 4002 Tset:

•600 346 Poseidon 4002•600 005 Temp-1Wire 3m•600 329 Temp-1Wire Rack19•600 377 L profile 19" size•600 080 12V Wall plug adaptor – EU•600 386 HWg PDMS 8 (SW license)• Big HWg paper box 2• Manual + CD

10

Page 11: Poseidon 4002  Rack monitoring

Typical Application Data centers Telecom rooms Network infrastructure

Det Control

Remote reset

10m

°C

°C

°C%RH

Temperatue probe 3m

Temperature probe for Rack montage

Closed Door detector

Dry Contact input

Smoke detector

Water Leak detector

AirFlow detector

Temperature & Humidity probe (Rack)

SMS

RS-232

GSM modem

I1 I6 O1 O2S1 S2 S3 S4

UPS monitoring Rack monitoring

A/C monitoring and control

11

Page 12: Poseidon 4002  Rack monitoring

Poseidon 4002 Alarming

SNMP

SMSGSM -> GSM

Email - SMTP

Switch power

Internet -> GSM

Local relay output

Remote relay over IP

4 destinations

12

Page 13: Poseidon 4002  Rack monitoring

Local relay output

13

ON

Local thermostat function, relay switched by sensor value.

Page 14: Poseidon 4002  Rack monitoring

GSM gateway function

Poseidon 4002 with GSM modem is SMS gateway for sending SMS from other Poseidon units on local network.You need one GSM modem and one SIM card only per server room.

14

Telephone number of Mr. Green (on this drawing) you define on Poseidon 4001 web page (source of green alert)SMS can be sent from Poseidon 3266, 4001, 4002Communication is based on TCP/IP protocol (Soap) and SMS is postponed when GSM modem is busy.

Page 15: Poseidon 4002  Rack monitoring

Poseidon 4002: complete solution

Poseidon 4002 is a 19" 1U rack mount system for datacenter monitoring. The Poseidon

solution monitors temperature, humidity, electricity supply, access to the room, detectors.

Alerting works by e-mail, SNMP traps, SMS, output relays.

Voltage -48V DC

Current 30A AC

Fan failure detector

Water leak detector

Voltage 110/230 AC Control/detector

Relay outputs

Humidity

Temperature Smoke detector

Door opening detector

Energy meter

GSM modem support (IP SMS GW function)

15

Page 16: Poseidon 4002  Rack monitoring

16

Summary

1) Check the Poseidon 4002 online (online demo).

2) Download flyer or manual

3) Order the Poseidon 4002 Tset for your first steps..