pumping station systems - grundfosnet.grundfos.com/appl/ccmsservices/public/... · pumping station...
TRANSCRIPT
GRUNDFOS DATA BOOKLET
Pumping station systems50/60 HzPS.W.04-20
Ta
ble
of c
on
ten
ts
2
Pumping station systems
1. Introduction 3Features and benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Component overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Identification 4
3. Construction 6Pumping station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Pumping station variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Valve chamber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Bottom variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Cover variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Pipe variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Outlet variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Baffle plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Screen basket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Level systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4. Operation 12Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Installation and operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5. Pump controllers 14IO 113 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14SM 113. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14Level controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14CU 100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16CUE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16AUTOADAPT pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
6. Selection 19Selection of products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19CE approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Product variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7. Technical data 20Starting frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Sump volume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
8. Accessories 22
9. Grundfos Product Center 23
Intr
od
uc
tio
n
Pumping station systems 1
1. Introduction
Grundfos pumping stations are prefabricated pumping stations designed for collecting and pumping of drainage water, rainwater or wastewater.The pump pit is made of polyethylene (PE-HD) or polypropylene (PP), and it comes with outlet pipe and valves fitted. The pump(s) may be supplied separately.The pipes are made of polyethylene (PE) or stainless steel (AISI 304 or AISI 316).Depending on the pit size and application, the covers come in PE or aluminium.The pump type depends on the pumped liquid.The drainage water, rainwater or wastewater is led into the pit. When the liquid in the pit reaches the start level, the pump(s) will start and pump the liquid further in the system to a sewage treatment plant or sewer.
Features and benefits
The complete systemNow, all the components of your pumping stations can be Grundfos quality. To complement our range of high-quality pumps and pumping equipment, we have our flexible welded pumping station solutions featuring all the qualities you need:.• sturdy materials• well-designed polyethylene or polypropylene pits• all necessary accessories such as pipes, valves and
inlet screen, as well as reliable controllers.You get a complete pumping station ready to be installed. Getting everything from one supplier, you can be certain that all components meet the most stringent quality requirements and fit perfectly together.Once the pumping station is installed, you will find that maintenance is reduced to an absolute minimum.The combination of sturdy materials and convenient access to valves and pumps not only makes service and maintenance easier, it also makes them much less frequent.
Advantages• Corrosion-free materials
Grundfos pumping station are made from corrosion-free materials throughout. This uncompromising choice of materials and the unique design make the pumping stations remarkably service-friendly and reliable.
• Modular flexibilityThe welded pumping station consist of four main elements(1: – One or two of our highly efficient and reliable
pumps(2
– a pit in the size to suit your requirements– all pipes and valves– controllers to ensure operational efficiency and
safety.(1 Separate valve chamber available on request.(2 Three and four pumps available as FPV option.
• Many sizes availableThe pits are available in various sizes, comprising five diameters and complete flexibility regarding depths.
• Installation and service friendlyThe pit has an extended bottom plate to secure the pit from uplift when installed in areas with high groundwater level. For large pits the design includes inclined bottom plates to improve the self-cleaning effect and thereby limit sludge and odour problems. You can reach all components needed in the pumping station from the top. In pit sizes smaller than D1250, the auto coupling is secured in the bottom position without any use of screws. It is possible to remove the coupling together with the pipes without entering the pit.
Component overviewThe components of the pumping station are selected according to Grundfos’s principles of high reliability, long life and great consideration for the environment during production, operation and disposal.
Fig. 1 Example of pumping stationTM
06 9
860
3517
Pos. Description
1 Pit
2 Cover
3 Pipes
4 Non-return valve
5 Isolating valve
6 Pipe coupling
7 Auto coupling
8 Guide rails
9 Guide rail holders
10 Level control system
2
3
4
5
10
8
1
9
6
3
7
3
Ide
ntific
atio
n
4
Pumping station systems2
2. Identification
Nameplate, PS.S and PS.M
Fig. 2 Nameplate, PS.S
Fig. 3 Nameplate, PS.M
Type key, PS.S and PS.MExample: PS.S.W.17.25.SEG.LCD110.FS2
* Without CE approval.
TM06
174
3 27
14TM
07 0
436
5017
Pos. Description
1 Product number
2 Production site
3 Type designation
4 Country of origin
5 Weight
6 Production code, year and week
7 Installation and operating instructions, publication number
8 Product number, pit
9 Product number, pump
10 Product number, pump controller
11 Product number, level controller
12 Product number(s), accessories
13 Not filled in
Code Explanation Designation
PS Grundfos pumping stationS CE-marked system
System typeM Modular system*R Rotation-moulded PEW Welded PE or PP04 400 mm
Pit sump diameter [mm] x 100
05 500 mm06 600 mm08 800 mm10 1000 mm12 1200 mm17 1700 mm20 2000 mm25 2500 mm Pit depth [mm] x 100
1 2
3
4
9
10
11
12
5
6 7
8 13 13
DK-8850 Bjerringbro, Denmark 9915
3401
ModelType PS.M.W.17.25.SEG.LCD.10.FS2
Pumping Station Modular
Made in WeightP.c.
Well cpl. Pump cpl.Control SystemAccessories
Level System
1 2
5
79
13118
6
3
4
10
12
CC Unilift CC
Pump type
KP Unilift KPAP12 Unilift AP12.50AP35 Unilift AP35, Unilift AP12.40AP50 Unilift AP50APB Unilift AP35B, Unilift AP50BSEG SEGDP/EF DP (0.6 - 1.5 kW), EF
DP/SL DP (2.6 kW), SL1.50.65 and SLV.65.65
DPK DPK, DPK.VSE/SL SE/SLX No Grundfos controller
Pump controller
BIP Built into the pumpCU Control unitLC231S Level controllerLC241S Level controllerLC231D Level controller - two pumpsLC241D Level controller - two pumpsLC107 Level controllerLC108 Level controllerLC110 Level controllerLC115 Level controllerLCD107 Level controller - two pumpsLCD108 Level controller - two pumpsLCD110 Level controller - two pumpsLCD115 Level controller - two pumpsDC318 Dedicated ControlsDC319 Dedicated ControlsDCD318 Dedicated Controls - two pumpsDCD319 Dedicated Controls - two pumpsBIP Built into the pump
Level controller
AB2 Two air bellsAB3 Three air bellsFS2 Two float switchesFS3 Three float switchesFS4 Four float switchesEL3 Three electrodesEL4 Four electrodesEL5 Five electrodesPT Pressure transducer
PF1 Pressure transducer and one float switch
PF2 Pressure transducer and two float switches
Code Explanation Designation
Ide
nti
fic
ati
on
Pumping station systems 2
Nameplate, PS.W
Fig. 4 Nameplate, PS.W
Type key, PS.WExample: PS.W.20.25.D.GC.304.100.A100.SEG
TM06
124
9 34
14
Pos. Description
1 Product number
2 Production site
3 Type designation
4 Country of origin
5 Weight
6 Production code, year and week
7 Installation and operating instructions, publication number
8 Not filled in
Code Explanation Designation
PS Grundfos pumping station
W Welded PE or PP Pit type and material
04 400 mm
Pit sump diameter [mm] x 100
06 600 mm
08 800 mm
10 1000 mm
20 2000 mm
xx x 100 Pit depth [mm] x 10025 2500 mm
N No pump
Number of pumpsS One pump
D Two pumps
DC Direct outlet, common
Pipe designDS Direct outlet, separated
GC Goose neck, common
NV No valves, separated
TypeStandards used: EN 12050-1 or EN 12050-2
Model
WeightP.c.
Made inEU declaration of performance
Denmark
P10
986467101325
Notified body:0197 DK-8850 Bjerringbro, Denmark 9849
5490
1 3 2
74 8 56
Stainless steel EN 1.4301 / AISI 304:
Pipe material and diameter
304.32 DN 32 (1")
304.40 DN 40 (1 1/2")
304.50 DN 50 (2")
304.65 DN 65 (2 1/2")
304.80 DN 80 (3")
304.100 DN 100 (4")
304.125 DN 125 (5")
304.150 DN 150 (6")
Stainless steel EN 1.4401 / AISI 316:
316.32 DN 32 (1")
316.40 DN 40 (1 1/2")
316.50 DN 50 (2")
316.65 DN 65 (2 1/2")
316.80 DN 80 (3")
316.100 DN 100 (4")
316.125 DN 125 (5")
316.150 DN 150 (6")
Polyethylene:
PE.63 D63 mm (2")
PE.75 D75 mm (2 1/2")
PE.90 D90 mm (3")
PE.110 D110 mm (4")
PE.160 D160 mm (6")
Auto-coupling:
Installation type
A40 DN 40 pump connection
A50 DN 50 pump connection
A65 DN 65 pump connection
A80 DN 80 pump connection
A100 DN 100 pump connection
A150 DN 150 pump connection
Free-standing:
S Free-standing pump
CC Unilift CC
Pump type
KP Unilift KP
AP12 Unilift AP12.50
AP35 Unilift AP35, Unilift AP12.40
AP50 Unilift AP50
APB Unilift AP35B, Unilift AP50B
SEG SEG
DP/EF DP (0.6 - 1.5 kW), EF
DP/SL DP (2.6 kW), SL1.50.65 and SLV.65.65
SE/SL SE/SL
Code Explanation Designation
5
Co
ns
truc
tion
6
Pumping station systems3
3. Construction
Pumping station
Fig. 5 Grundfos pumping stations, D400 to D2000
Components and material specification
TM07
098
7 09
18 -
TM06
345
8 09
18 -
TM06
345
9 09
18
5
4
3
8
6
2
9
7
1
2
5
4
8
1
9
6
3
10
7
2
5
3
1
6
D2000D400 D600/D800/D1000
Pos. Component Material descriptionDIN W.-Nr./
EN standardAISI/ASTM D400 D600 D800 D1000 D2000
1 TankPP HD - - ● ● ● ● ●PE HD - - ● ● ● - -
2Cover
PE HD - - ● - - - -Aluminium - - - ● ● ● ●
Safety gridAluminium - - - - - - ●Stainless steel 1.4301 / 1.4401 304 / 316 - - - - ●
3 PipesStainless steel 1.4301 / 1.4401 304 / 316 ● ● ● ● ●PE HD - - ● ● ● ● ●
4 Non-return ball valve
Rubber and stainless steel NBR / 1.4301 NBR / 304 ● ● ● ● ●PP - - - ● ● ● -Stainless steel 1.4401 316 ● ● ● ● ●
Cast iron GJS-400-15(GGG-40) - ● ● ● ● ●
5Ball closing valve
PP - - ● ● ● ● ●
Stainless steel1.4301 304 ● ● ● ● ●1.4401 316 ● ● ● ● -
Isolating valve Cast iron GJS-400-15(GGG-40) - ● ● ● ● ●
6 Pipe coupling
PP, quick coupling - - ● ● ● ● ●Stainless steel, quick coupling 1.4301 / 1.4401 304 / 316 ● ● ● ● ●PE, flanged - - - - ● ● ●Stainless steel, flanged 1.4301 / 1.4401 304 / 316 - ● ● ● ●
7 Auto couplingCast iron EN-GJL-250/EN-JL 1040 - - ● ● ● ●Stainless steel 1.4301 304 - ● ● ● ●
8 Guide railsStainless steel 1.4301 / 1.4401 304 / 316 - ● ● ● ●Galvanized steel - - - ● ● ● -
9 Guide rail holders Stainless steel 1.4301 / 1.4401 304 /316 - ● ● ● ●
10 Brackets for level sensors Stainless steel 1.4301 / 1.4401 304 / 316 ● ● ● ● ●
- Screws Stainless steel 1.4301 / 1.4401 304 / 316 - ● ● ● ●
Co
ns
tru
cti
on
Pumping station systems 3
Pumping station variants
Fig. 6 Pit with free-standing pump with goose neck outlet
Fig. 7 Pit with two pumps on auto coupling and goose neck outlet
Fig. 8 Pit with two pumps on auto coupling and valve chamber, only on request
Valve chamber
Fig. 9 Valve chamber, only on request
Components and material specification
TM06
349
2 05
15TM
06 3
493
0918
TM03
402
9 14
06TM
03 4
029
1406
Pos. Component MaterialDIN W.-Nr./
EN standardAISI/ASTM
1 Valve chamber PE HD - -
2 Cover Aluminium or PE HD* - -
3 Isolating valve Epoxy-coated cast iron
GJS-500-7 / GGG-50 -
4 Non-return valve
Epoxy-coated cast iron
GJS-400-15 / GGG-40 -
5 Ladders Aluminium - -
6 PipesStainless steel 1.4301 /
1.4401304 / 316
PE - -PE HD: Polyethylene, high density*: Only available with reduced top
1
2
3
4 5
6
7
Co
ns
truc
tion
8
Pumping station systems3
Bottom variantsAll pits are fitted with standard bottom.
D400-1000
Finned tube with plate, made of polypropylene (PP) or polyethylene (PE).
D2000
Moulded tube, sandwich design for double plates and inclined bottom plate, made of polyethylene (PE).Iron cross for reinforcement.
Cover variantsAll pumping stations are equipped with a cover that can be locked. Pits with D2000 cover have a safety grid.
D400
Insulated polyethylene (PE HD) cover.
D600-1000
Aluminium cover. Safety grid is available as optional.
D2000
Aluminium, twelve-sided cover with ventilation and aluminium safety grid.
Safety gridSafety grids are mandatory for pits with a diameter of more than D1000. All Grundfos cylindrical pumping stations larger than D1000 are equipped with grids in aluminium or stainless steel.
TM06
346
4 05
15TM
06 3
464
0515
TM06
347
2 09
18
TM06
346
8 06
15TM
06 3
465
0615
Co
ns
tru
cti
on
Pumping station systems 3
Pipe variants
* For one pump installations.** For two pump installations.
Examples of pipe design
Pipe design
Stainless steel (EN 1.4301/AISI 304 or EN 1.4401/AISI 316)
Polyethylene (PE)
DN 32 DN 40 DN 50 DN 65 DN 80 DN 100 DN 125 DN 150 D63 D75 D90 D110 D160
GCGoose neck ● ● ● ● ●Goose neck, common ● ● ● ● ● ● ● ●Goose neck, common ● ● ● ● ●
DCDirect outlet, same outlet ● ● ● ● ● ● ● ● ● ● ● ● ●Direct outlet, separate outlet ● ● ● ● ● ● ● ● ● ● ● ● ●Direct outlet, without valves ● ● ● ● ● ● ● ● ● ● ● ● ●
TM06
348
8 05
15
TM06
348
2 05
15
TM06
348
4 05
15
Fig. 10 GC, pipe system with goose neck, PE outlet and stainless steel pressure pipe
Fig. 11 GC, pipe system (PE) with goose neck and stainless steel pressure pipe
Fig. 12 GC, pipe system with goose neck and common outlet
TM06
348
5 05
15
TM06
348
6 05
15
TM06
348
7 05
15
Fig. 13 DC, pipe system with direct, common outlet and stainless steel pressure pipes
Fig. 14 DC, pipe system for two pumps with direct, common outlet and stainless steel pressure pipes
Fig. 15 DC, pipe system with direct outlet, without valves
9
Co
ns
truc
tion
10
Pumping station systems3
Outlet variants
D75 to D160
Welded polyethylene (PE).
DN 40 to DN 65
Stainless steel (EN 1.4301 / AISI 304 or EN 1.4401 / AISI 316) with thread.
Baffle plateThe baffle plate slows the incoming flow of liquid and prevents splattering inside the pit.
Fig. 16 Baffle plate
Screen basketThe screen basket holds back solid materials, such as stones and branches in the incoming flow of liquid.
Fig. 17 Screen basket
TM06
347
8 05
12TM
06 3
478
0512
TM06
885
3 13
17
TM06
885
2 13
17
Co
ns
tru
cti
on
Pumping station systems 3
Level systems
Fig. 18 Float switch, pit less than 3 m
Fig. 19 Float switch, pit larger than 4 m
Fig. 20 Electrodes, pit less that 3 m
Fig. 21 Electrodes, pit larger than 4 m
TM06
347
7 05
15TM
06 3
476
0515
TM06
347
4 05
15TM
06 3
473
0515
11
Op
era
tion
12
Pumping station systems4
4. Operation
Operating conditions
Pumped liquids
• Drainage water• rainwater (surface water)• wastewater.
Liquid temperature
The liquid temperature that can be handled depends on the pump selected. See the installation and operating instructions for the pump. In general, the maximum liquid temperature is 40 °C. If your liquid has a higher temperature, contact your local Grundfos company.For certain pump types, 60 °C are permissible for short periods. However, at 60 °C the pit material begins to soften.
Acids and alkalis
The pump pit is resistant to strong acids and alkalis as well as solvents.The pump are supplied with the pump pit and are normally resistance to pH values between 4 and 10. In case of doubt, contact your local Grundfos company.
Viscosity
Very thick wastewater must not be led into the pit. See also the installation and operating instructions for the pump.
Density
Maximum 1100 kg/m3.
Installation and operationLocal regulations and legal requirements must always be met. For further information, see the installation and operating instructions for the pumping station.
Installation of pumpSome versions come without the pump installed. For installation and startup of the pump, see the installation and operating instructions for the pump.Note: The pump must be lowered carefully into the pit in order to avoid damage to the pump and pit.
Pipes with flange connectionsIf the pit is to be installed at temperatures below 0 °C, loosen all flange bolts and retighten them when the pumping station has been installed. In this way, you prevent stress in the pipes.
Fitting the chainIn the case of pumps on auto coupling, we recommend that you fit the chain in the foremost lifting eye of the lifting bracket. When lifting the pump make sure to use a lifting device that is approved for the weight of the pump. Make sure to keep body parts away from a lifted pump.
Fig. 22 Chain fitted to pump
Installation of level controllerSee the installation and operating instructions for the controller.
TM02
934
1 25
14
Op
era
tio
n
Pumping station systems 4
Location of inletThe pit inlet must be located within the area shown in figs 23 and 24 as it will interfere with pipes and valves.
Fig. 23 Location of inlet in relation to pipes with one pump
Fig. 24 Location of inlet in relation to pipes with two pumps
StartupSee the installation and operating instructions for the pump and the controller, respectively.Note: The controller must not be installed in the pit.
MaintenanceSee the installation and operating instructions for the pump and the controller, respectively.It is important that the pit cover is properly secured so that unauthorised persons cannot remove it.
TM06
985
6 35
17TM
06 9
857
3517
220°
190°
13
Pu
mp
co
ntro
llers
14
Pumping station systems5
5. Pump controllers
IO 113IO 113 is a protection module for Grundfos wastewater pumps.The module has inputs for digital and analog sensors and can stop the pump if a sensor indicates a pump fault.The module is connected to the Dedicated Controls system and allows advanced monitoring functions, such as: • motor temperature• moisture in motor• water in oil or water in air• insulation resistance.
SM 113SM 113 is used for collection and transfer of sensor data. The module works together with IO 113 through power-line communication using the Grundfos GENIbus protocol.The module can collect data from these devices:• 3 current sensors, 4-20 mA• 3 Pt1000 thermal sensors• 1 thermistor circuit (3 sensors in series)• 1 digital input.
Level controllersGrundfos offers dedicated pump controllers for monitoring liquid levels in the wastewater collecting tanks to ensure correct operation and protection of the pumps. Grundfos pump controllers that are ideal to be connected to Grundfos wastewater pumps include:• Grundfos Dedicated Controls (DC)• Grundfos LC controllers
Grundfos DC Controllers
Fig. 25 Grundfos Dedicated Controls control cabinet
Grundfos Dedicated Controls (DC) is a control system designed for installation in municipal wastewater transportation, commercial buildings or network pumping stations with up to six wastewater pumps and an optional mixer or a flush valve.Advanced control and data communication are also possible with the Grundfos Dedicated Controls system. The control cabinets are delivered with a built-in main switch and thermal magnetic circuit breaker.Features and benefits:• Advanced Flow Calculation• Automatic energy optimisation• Easy installation and configuration• Configuration wizard• Electrical overview• Advanced data communication• Advanced alarm and warning priority• Supports several languages• Daily emptying• Mixer control or flush valve• User-defined functions• Anti-blocking• Start level variation• Advanced pump alternation with pump groups• SMS scheduling• Communication to SCADA, BMS, GRM or cell
phone.
Gr-
1016
086
Pu
mp
co
ntr
oll
ers
Pumping station systems 5
Dedicated Controls is ordered either with or without a built-in communication interface module (CIM).The communication module enables the possibility for fieldbus protocol (e.g. PROFIBUS DP, Modbus RTU and PROFINET IO/Modbus TCP) and the communication line.For further information about Grundfos Dedicated Controls, please see Grundfos Product Center:• Grundfos Dedicated Controls, brochure
http://net.grundfos.com/qr/i/96925597• Grundfos iSolutions, brochure
http://net.grundfos.com/qr/i/99249771• Grundfos Controls Guide, product guide
http://net.grundfos.com/qr/i/97954965
Additional features, CUE or VFD
The CUE/VFD (optional), which is either a Grundfos variable frequency drive or a general variable frequency drive, offers better pump protection and a more steady flow through the pipe system.In addition, Grundfos CUE,VFD offers these features and benefits:• anti-blocking• automatic energy optimisation• specific-energy test• output frequency• monitoring of:
– voltage*– current*– phase sequence*– power*– energy*– torque*
• reverse start**• run flushing• stop flushing• PID control.* These functions are only available with a Grundfos
CUE.** We do not recommend reversing at full speed at
any time. When reduced reverse operation settings are set, make sure constant torque is enabled in Variable Frequency Drive (VFD) (i.e. Grundfos CUE, Siemens Simatic, ABB, Schneider Electric etc.) to have maximum torque available when reversing.
LC range
Grundfos LC level controllers are available in two variants:LC 231 - a compact solution complete with certified motor protectionLC 241 - a cabinet solution offering modularity and customizationDesigned for installations with one or two pumps, the Grundfos LC level controller is ideal for emptying and filling related to small wastewater transport, commercial buildings and tank-filling applications.The controller can support up to five control levels for both analogue level transmitter or float switch operation.For emptying applications, if the tank or pit is completely filled, the controller will run all pumps to empty. The controller is equipped with Grundfos configurable input/output terminals, giving full flexibility for all applications. Daily control, supervision and commissioning is straightforward with the intuitive and easy-to-use user interface. This saves you valuable time when getting started, and in your daily interaction with pumps and the controller. The controller integrates seamlessly into the Grundfos range of communication modules, ensuring an easy fit into any supervisory system such as SCADA or Grundfos CLOUD Solution.
Fig. 26 LC 231 Compact solution
Fig. 27 LC 241 Cabinet solution
Gr-
1031
087
Gr-
1031
129
15
Pu
mp
co
ntro
llers
16
Pumping station systems5
CU 100The CU 100 control box is designed for the starting, operation and protection of small wastewater pumps.The control box is available in several variants which can be used for the following:• single-phase pumps (up to and including 9 A)• three-phase pumps (up to and including 5 A).The control box is also suitable for the following:• start/stop by means of a float switch• manual start/stop.During manual operation, start and stop the pump with the on/off switch.During automatic operation, the float switch will start and stop the pump.For further information, see the installation and operation instructions for CU 100 in Grundfos Product Center at www.grundfos.com.
Fig. 28 CU 100
CUEGrundfos CUE is complete range of external frequency converters designed for speed control of a wide range of Grundfos pumps.
Fig. 29 CUE
CUE has a built-in PI controller and offers the same functionality and user-interface as Grundfos S-pumps. CUE solutions can thus be seen as an extension to the S-pump range.CUE offers following benefits:• speed control of pumps up to 250 kW (also pumps
installed in potentially explosive environments)• 2 alarm outputs (C, NO, NC)• 1 sensor (4-20 mA)• 2 Pt100 or Pt1000 sensors.
TM02
645
9 07
03
Gr-
1015
227
Pu
mp
co
ntr
oll
ers
Pumping station systems 5
AUTOADAPT pumps
Grundfos CIUGrundfos CIU is used as a communication interface between a Grundfos product and a main network. CIU is used as an interface for the following functions:• Configuration of pump parameters required for
water level control.• Online monitoring of pit and pump values.• Manual water level control (forced start/stop).• Collection of measured and logged data that are
valuable for pump service and pit optimisation.CIU is designed for use together with Grundfos AUTOADAPT pumps. You can establish communication via Grundfos GO or by using the main network interface of CIU.Available CIU:• CIU 152 PROFIBUS DP• CIU 902 (without CIM module)• CIU 202 Modbus• CIU 252 GSM, GPRS• CIU 272 GRM (Grundfos Remote Management).CIU incorporates one or two modules:• multipurpose I/O module with I/O functionality, IR
communication interface and power-line communication.
• CIM module (optional).For further information about the CIM module fitted, see the installation and operating instructions for the module.If a CIM module is fitted in the CIU unit, the sensors connected to the digital input of the I/O module can be remotely monitored from a centrally located SCADA system.
Grundfos GOGrundfos GO is designed for wireless IR communication with Grundfos products. Grundfos GO can communicate with the AUTOADAPT pumps via a CIU unit.Grundfos GO is to be regarded as an ordinary service and measuring tool and is therefore designed to withstand wear and stress from everyday use.
ADCThe ADC fuse box is designed for the protecting of the power supply for small wastewater pumps.
Fig. 30 ADC
The fuse box enables communication with the following:• Grundfos Remote Management, GRM• Grundfos GO• SCADA.The fuse box can be used with the following:• one-pump installation with or without CIU1)
• two-pump installation with or without CIU1)
• CIU units– CIU 202 Modbus RTU2)
– CIU 272 GRM2)
– CIU 9022)
– CIU 252 GSM complete2)
• optional service socket 230 V3) / 50 Hz2)
• optional socket for PC Tool link box2)
• optional fault indicator light mounted on top2)
• optional audio alarm, 100 dB2).1) With a CIU unit, a CIM module is needed. 2) Must be ordered with the control box.3) The modules come as two parts and must be assembled.
For further information, see the installation and operation instructions for the ADC in Grundfos Product Center at www.grundfos.com.
Gr-
1016
011
17
Pu
mp
co
ntro
llers
18
Pumping station systems5
1) If an SMS module is fitted.2) If a CIM 252 GSM/GPRS module is fitted.3) Built-in pressure transducer and dry-running sensor.4) Built-in, but a Grundfos CIU unit is required to get access to data or setting of parameters.5) Modbus, GSM, GPRS, SMS and GRM options.6) If Grundfos GO is used.7) Inputs for external sensors (NO or NC).
Name DC DCD LC CU 100 AUTOADAPT CIU
Application
One pump ● ● ● ● ● ●
Two pumps ● ● ● ●
Mixer ● ●
Backup battery ● ●
Level sensor
Float switches ● ● ● ● ● 7)
Electrodes ● ● 7)
Air bells ● ● 7)
Pressure transducer ● ● ● ● 3) ● 7)
Ultrasonic sensor ● ● ● 7)
Analog level sensor with safety float switches ● ● ● 7)
Starting method
Direct-on-line starting (DOL) ● ● ● ● ● ●
Star-delta starting ● ● ●
Soft starter ● ●
Basic functions
Start and stop of pump(s) ● ● ● ● ● ●
Pump alternation ● ● ● ●
High-level alarm ● ● ● ● ●
Dry-running alarm ● ● ● ● ●
Flow measurement (calculated or via flow sensor) ● ●
Pump statistics ● ● ● 4) ●
Conflicting levels alarm ● ●
Advanced functions
Start and stop delays ● ● ● ● ●
Motor temperature sensor ● ● ● ● 4) ●
Test run/antiseizing ● ● ● ● ●
Daily emptying (once a day) ● ● ●
Water-in-oil sensor input ● ●
Communication
SMS messaging ● 2) ● 2) ● 1) ● 2)
SCADA communication GSM/GPRS ● 2) ● 2) ● 2) ● 5)
User interface
Level indication ● ● ● ● 6)
Graphical display ● ● ● 6)
PC Tool WW Controls ● ● ●
Se
lec
tio
n
Pumping station systems 6
6. Selection
Selection of productsWhen ordering a Grundfos pumping station, you need to take the following six aspects into consideration:1. pump2. installation of pump3. diameter and depth of pit4. level control system5. pump controller6. accessories.
1. Pump
See the data booklet for the selected pump or Grundfos Product Center at www.grundfos.com and Type key, PS.W on page 5. For further information about Grundfos Product Center, see page 23.
2. Installation type of the pump
See Type key, PS.W on page 5.The pump(s) can be installed in two ways:• on a standard auto-coupling system on the bottom
of the pit• free-standing.
3. Diameter and depth of pit
The pit is available in various sizes. See Technical data on page 20 for dimensions and for calculation of needed volume.
Valve chambers
Valve chambers are separate pits that you can choose to avoid technical persons from entering the pumping station and to have sufficient space for the equipment.
4. Level control system
See Level systems on page 11 or Grundfos Product Center at www.grundfos.com.
5. Pump controller
See Operation on page 12 or Grundfos Product Center at www.grundfos.com.
6. Accessories
Depending on the installation type, accessories may be required. For selection of the correct accessories, see section Accessories on page 22.
CE approvalGrundfos welded pumping stations are CE-marked. Depending on the pump and controller selected, they are marked in accordance with one or several of the following directives:• EMC Directive• Low Voltage Directive• Machinery Directive.The declaration of conformity and declaration of performance can be seen in the installation and operating instructions for the products in question.
Product variantsIf you did not find the required pumping station in our standard range, please contact your local Grundfos company. We have other ranges of prefabricated pumping stations, but they vary from region to region.For large prefabricated pumping stations, please see Grundfos Product Center or contact your local Grundfos company for information about range and designs available in your region. We offer a huge range of large prefabricated pumping stations to fit our range of large pumps. This range covers versions up to 3 m in diameter and 12 m in depth in both glass-fibre-reinforced polyester, polyethylene and polypropylene.
Depth[mm]
D400 D600 D800 D1000 D2000
2250 ● ●2500 ● ●2750 ● ●3000 ● ●3250 ● ● ● ● ●3500 ● ● ● ● ●3750 ● ● ● ● ●4000 ● ● ● ● ●4250 ● ● ● ● ●4500 ● ● ● ● ●4750 ● ● ● ● ●5000 ● ● ● ● ●5250 ● ● ● ● ●5500 ● ● ● ● ●5750 ● ● ● ● ●6000 ● ● ● ● ●
19
Te
ch
nic
al d
ata
20
Pumping station systems7
7. Technical data
Description of the terms used in the following sections:• Total volume
The volume of the complete pit.• Emergency volume
The volume from the bottom of the pit to the lowest inlet.
• Sump volumeThe volume from the bottom of the pit to the start level.
• Effective volumeThe volume pumped in every pump cycle, that is the volume between the start and stop level.
Starting frequencyIn a pumping station, the water volume comprises the volume below the lowest pump stop level and the pumpable volume above this level, fluctuating with pump usage and incoming flow rate. The starting frequency of the pumps depends on the available pumpable volume and the incoming flow rate.The starting frequency Z is a function of the ratio between Qin/Q and Vh.
Note: If the maximum incoming flow rate is equal to the pump performance, the pump will be running permanently. When the actual pump capacity for single-pump operation is equal to the maximum peak inflow, Zmax will always appear when the inflow is half the pump capacity.
Zmax: maximum number of starts per hour.
Vh: necessary, minimum accumulated volume between start and stop..
Sump volumeIn installations where the expected maximum incoming flow Qin is less than 60 % of the selected pump performance, the accumulated sump volume must be calculated in such a way that there will be least two pump starts a day in order to prevent sedimentation in the sump.The following drawings show values of empty pits without pump, pipe, etc.
Fig. 31 Sump volume in relation to level, D400
Fig. 32 Sump volume in relation to level, D600
Qin = incoming flow rate [l/s]Q = pump performance [l/s]Vh = accumulated (effective) volume between start
and stop [m3]
Zmax = Q × 3.64 × Vh
Vh = Q × 3.64 × Zmax
TM06
417
6 16
15TM
06 4
177
1615
700
600
500
400
300
200
100
0
1000
900
800
0.088
0.076
0.063
0.050
0.038
0.025
0.013
0
0.126
0.113
0.101
mm m3
700
600
500
400
300
200
100
0
1000
900
800
0.198
0.170
0.142
0.113
0.085
0.057
0.028
0
0.283
0.255
0.226
mm m3
Te
ch
nic
al
da
ta
Pumping station systems 7
Fig. 33 Sump volume in relation to level, D800
Fig. 34 Sump volume in relation to level, D800
Fig. 35 Sump volume in relation to level, D1000
Fig. 36 Sump volume in relation to level, D1000
Fig. 37 Sump volume in relation to level, D1000
Fig. 38 Sump volume in relation to level, D2000
TM06
417
8 16
15TM
06 4
180
1615
TM06
417
9 16
15
700
600
500
400
300
200
100
0
1000
900
800
0.318
0.267
0.217
0.167
0.117
0.068
0.027
0
0.468
0.418
0.368
mm m3
250
700
600
500
400
300
200
100
0
1000
900
800
0.329
0.279
0.228
0.178
0.128
0.078
0.034
0
0.480
0.429
0.379
mm m3
360
700
600500
400
300200100
0
1000
900800
0.460
0.382
0.303
0.225
0.1490.084
0.034
0
0.6960.617
0.539
mm m3250
TM06
418
1 16
15TM
06 4
182
1615
TM06
418
6 16
15
700
600500
400
300
200100
0
1000
900800
0.489
0.410
0.3320.253
0.1750.103
0.044
0
0.724
0.6460.567
mm m3
360
700
600500
400
300
200100
0
1000
900800
0.550
0.4710.393
0.3140.2360.157
0.0790
0.7850.7070.628
mm m3
700600500400300200100
0
1000900800
1.9471.6331.3191.0100.7170.4480.2080
2.8902.5762.261
mm m3
21
Ac
ce
ss
orie
s
22
Pumping station systems8
8. Accessories
Pos. TypePipe diameter
[mm]Description Product number
1
TM04
460
5 17
09
50
Sleeve LM100
91712027
63 91713490
75 91712028
90 91712029
110 96641837
160 96641838
200 91712032
2
TM06
423
5 17
15
50 Hole saw, extended, 60 mm 91712020
63 Hole saw, extended, 75 mm 99416085
75 Hole saw, extended, 87 mm 91712021
90 Hole saw, extended, 102 mm 99421349
110 Hole saw, extended, 127 mm 96651610
160 Hole saw, extended, 177 mm 96651612
200 Hole saw, extended, 212 mm 99401414
3
TM04
460
2 17
09
Up to DN 65
Insulation jacket for single-pump installation.For frost protection, the insulation jacket is fitted directly over pipes and valves.
96571529
Insulation jacket for two-pump installation.For frost protection, the insulation jacket is fitted directly over pipes and valves.
96653751
4
TM04
460
3 17
09
50
Vent pipe package
96571531
90 98171612
6
TM06
885
9 13
17
DN 50 / DN 65
Expansion cone
99134840
DN 50 / DN 80 99134841
DN 65 / DN 80 99134842
DN 65 / DN 100 99135003
DN 80 / DN 100 99135004
DN 80 / DN 125 99135005
DN 100 / DN 125 99135006
DN 100 / DN 150 99135007
DN 125 / DN 150 99135008
DN 125 / DN 200 99135009
DN 150 / DN 200 99135010
DN 150 / DN 250 99135011
DN 200 / DN 250 99135012
DN 200 / DN 300 99135043
DN 250 / DN 300 99135044
Gru
nd
fos
Pro
du
ct
Ce
nte
r
23
Pumping station systems 9
9. Grundfos Product Center
"REPLACEMENT" enables you to find a replacement product. Search results willinclude information on the following:
• the lowest purchase price• the lowest energy consumption• the lowest total life cycle cost.
"CATALOGUE" gives you access to the Grundfos product catalogue.
"LIQUIDS" enables you to find pumps designed for aggressive, flammable or other special liquids.
All the information you need in one place Downloads
Performance curves, technical specifications, pictures, dimensional drawings, motor curves, wiring diagrams, spare parts, service kits, 3D drawings, documents, system parts. The Product Center displays any recent and saved items - including complete projects - right on the main page.
On the product pages, you can download installation and operating instructions, data booklets, service instructions, etc. in PDF format.
Online search and sizing tool to help you make the right choice.
http://product-selection.grundfos.com
"SIZING" enables you to size a pump based on entered data and selection choices.
This drop-down menu enables you to set the search function to "Products" or "Literature".
GRUNDFOS A/S DK-8850 Bjerringbro . DenmarkTelephone: +45 87 50 14 00www.grundfos.com
98898658 1219
ECM: 1274832 Trad
emar
ks d
ispl
ayed
in th
is m
ater
ial,
incl
udin
g bu
t not
lim
ited
to G
rund
fos,
the
Gru
ndfo
s lo
go a
nd “b
e th
ink
inno
vate
” are
regi
ster
ed tr
adem
arks
ow
ned
by T
he G
rund
fos
Gro
up. A
ll rig
hts
rese
rved
.©
201
9 G
rund
fos
Hol
ding
A/S
, all
right
s re
serv
ed.