svp - limerick · ilin2 scale proposed foul & surface water layouts 1:250 @ a1 150-fw mh 3.0...

3
IL IN2 SCALE PROPOSED FOUL & SURFACE WATER LAYOUTS 1:250 @ A1 150 - FW MH 3.0 CL= +20.20m IL= +17.71m SW MH 1.0 CL = +19.67m IL = +18.10m SW MH 4.0 CL = +20.10m IL IN1 = +17.75m IL IN2 = +18.86m IL OUT = +17.74m SW MH 4.1 CL = +20.60m IL = +19.25m FW MH 1.0 CL = +19.70m IL = +18.20m FW MH 4.0 CL =+ 20.10m IL IN1 = +17.64m IL IN2 = +18.74m IL OUT = +17.64m FW MH 4.1 CL= +20.60m IL= +19.30m FW MH 5.0 CL = +19.12m IL = +17.22m SW FC MH 5.0 CL = +19.12m IL = +17.50m 300Ø SW @ 1:196 150Ø FW @ 1:92 300Ø SW @ 1:152 225Ø SW @ 1:78 150Ø FW @ 1:60 375Ø SW @ 1:200 150Ø FW @ 1:111 150Ø FW @ 1:27 23.45 RIDGE FFL=+19.11m FFL=+18.60m FSMH 2 CL=+ 18.60m I.L=+16.32m FSMH1 CL=+ 19.00m I.L=+ 16.94m SSMH1 CL=+ 19.00m I.L=+17.24m SSMH 2 CL=+ 18.60m I.L=+16.62m 1:100 FALL 1:100 FALL AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ AJ SVP SVP SVP SVP SVP SVP SVP SVP AJ AJ AJ AJ AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ AJ SVP SVP AJ AJ AJ AJ AJ AJ AJ AJ IC AJ AJ AJ AJ AJ AJ AJ SVP SVP AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ IC IC IC IC AJ AJ AJ AJ IC SVP SVP IC IC AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ SVP SVP IC AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ AJ SVP SVP IC RG IL IN2 IL OUT IL IN1 150Ø FW @ 1:122 IL IN1 IL OUT 300Ø SW @ 1:148 IC SW MH 2.1 CL=+19.94m IL = +18.55 m 225Ø SW @ 1:140 AJ 150Ø FW @ 1:120 FW MH 2.0 CL= +19.90m IL= +17.83m SW MH 2.0 CL = +19.90m IL IN1 = +17.91m IL IN2 = +18.46m IL OUT = +17.91m IL IN2 IL IN1 IL OUT SW MH 3.0 CL=+ 20.20m IL = +17.80m ATTENUATION TANK CL = 'VARIES' TL T = +19.03m IL T = +17.83m Storage Volume = 325m³ RG RG RG RG PETROL INTERCEPTOR IC IC IC IC IC IC IC IC 225Ø SW @ 1:35 AJ AJ AJ AJ AJ AJ AJ AJ AJ DENOTES SITE BOUNDARY NEW SURFACE WATER SEWER BY OTHER NEW SURFACE WATER MANHOLE BY OTHER NEW SURFACE WATER SEWER NEW SURFACE WATER MANHOLE NEW SURFACE WATER FLOW CONTROL MANHOLE PROPOSED SURFACE WATER ACCESS JUNCTION PROPOSED ROAD GULLY PROPOSED PETROL INTERCEPTOR PROPOSED ATTENUATION TANK NEW FOUL WATER SEWER BY OTHER NEW FOUL WATER MANHOLE BY OTHER NEW FOUL WATER SEWER NEW FOUL WATER MANHOLE PROPOSED FOUL INSPECTION CHAMBER PROPOSED FOUL ACCESS JUNCTION AJ RG LEGEND: SWMH 1.1 = MANHOLE NO. CL = COVER LEVEL IL = INVERT LEVEL FWMH 1.1 = MANHOLE NO. CL = COVER LEVEL IL = INVERT LEVEL IC AJ DEERPARK ADARE Co. LIMERICK SOUTH SITE - PROPOSED FOUL & SURFACE WATER LAYOUTS LIMERICK CITY & COUNTY COUNCIL CITY HALL MERCHANTS QUAY LIMERICK PLANNING CONSULTING ENGINEERS & PROJECT MANAGERS 30 DRUMCONDRA ROAD UPPER Tel: 061 310 701 (Limerick) email: [email protected] DRUMCONDRA DUBLIN 9 web: www.dennanyreidy.ie Tel: 01 216 2956 (Dublin) THE PARK LORD EDWARD St. LIMERICK LIMERICK: DUBLIN: V94 840C D09 FT7K DATE REV. DESCRIPTION PRODUCER DATE VERIFIER DATE APPROVER NOTES: 1. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES UNLESS NOTED OTHERWISE. 2. USE FIGURED DIMENSIONS ONLY. DO NOT SCALE. 3. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ENGINEER'S, ARCHITECT'S AND SERVICE ENGINEER'S DRAWINGS AND SPECIFICATIONS. 4. ALL WORKS TO BE CARRIED OUT IN ACCORDANCE WITH CURRENT BUILDING REGULATIONS. 1:250 @ A1 AD JR L200-150 B A COPYRIGHT AND OWNERSHIP OF THIS DRAWING IS VESTED IN DENNANY REIDY ASSOCIATES LTD. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR TRANSMITTED IN ANY FORM OR STORED IN ANY RETRIEVAL SYSTEM OF ANY NATURE WITHOUT THE WRITTEN PERMISSION OF DENNANY REIDY ASSOCIATES AS COPYRIGHT HOLDER EXCEPT AS AGREED FOR USE ON THE PROJECT FOR WHICH THE DOCUMENT WAS ORIGINALLY ISSUED. ALL RIGHT RESERVED BY THE LAW OF COPYRIGHT AND BY INTERNATIONAL COPYRIGHT CONVENTIONS ARE RESERVED TO DENNANY REIDY ASSOCIATES LTD. 31/07/19 IRISH WATER STANDARD DETAILS AND CODE OF PRACTICE: ALL OF THE SITE DRAINAGE WORKS SHOULD BE CARRIED OUT IN ACCORDANCE WITH IRISH WATER'S (IW) "WASTEWATER INFRASTRUCTURE STANDARD DETAILS" AND "CODE OF PRACTICE FOR WASTEWATER INFRASTRUCTURE". FOR REINFORCED IN SITU ITEMS SUCH AS MANHOLES ETC, ALLOW H12 REBAR@200c/c BOTH FACES. NOTE THAT PRECAST OPTIONS ARE ALSO SPECIFIED. PIPE MATERIALS: 1. SERVICE CONNECTIONS FROM DWELLING TO BE 100mm Ø UNPLASTICISED PVC IN ACCORDANCE WITH SECTION 3.13 OF IW CODE PRACTICE. 2. SITE SEWER TO BE THERMOPLASTIC STRUCTURED WALL PIPES IN ACCORDANCE WITH SECTION 3.13 OF THE IW CODE OF PRACTICE. TESTING: 1. SITE SEWER AND MANHOLES TO BE TESTED IN ACCORDANCE WITH SECTION 4.10 OF IW CODE OF PRACTICE. 2. CCTV AND MANHOLE CONDITION SURVEYS TO BE CARRIED OUT IN ACCORDANCE WITH SECTION 1.9 OF IW CODE OF PRACTICE IN ADVANCE OF THE DEFECTS LIABILITY PERIOD. NOTE: ALL MANHOLE COVER LEVELS TO BE CHECKED IN SITU TO ENSURE THAT THEY ARE LEVEL WITH THE SURROUNDING FINISHED SURFACES. 22/08/19 A SURFACE WATER REVISED CMcD AD JR CMcD CMcD 22/08/19 22/08/19 N NE E SE S SW W NW N 10/10/19 B GENERAL REVISIONS CMcD AD JR 10/10/19 10/10/19 B

Upload: others

Post on 15-May-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SVP - Limerick · ilin2 scale proposed foul & surface water layouts 1:250 @ a1 150-fw mh 3.0 cl= +20.20m il= +17.71m sw mh 1.0 cl = +19.67m il = +18.10m sw mh 4.0 cl = +20.10m il

I

LIN

2

SCALE

PROPOSED FOUL & SURFACE WATER LAYOUTS

1:250 @ A1

150

-

FW MH 3.0

CL= +20.20m

IL= +17.71m

SW MH 1.0

CL = +19.67m

IL = +18.10m

SW MH 4.0

CL = +20.10m

IL

IN1

= +17.75m

IL

IN2

= +18.86m

IL

OUT

= +17.74m

SW MH 4.1

CL = +20.60m

IL = +19.25m

FW MH 1.0

CL = +19.70m

IL = +18.20m

FW MH 4.0

CL =+ 20.10m

IL

IN1

= +17.64m

IL

IN2

= +18.74m

IL

OUT

= +17.64m

FW MH 4.1

CL= +20.60m

IL= +19.30m

FW MH 5.0

CL = +19.12m

IL = +17.22m

SW FC MH 5.0

CL = +19.12m

IL = +17.50m

3

0

0

Ø

S

W

@

1

:

1

9

6

1

5

0

Ø

F

W

@

1

:

9

2

300Ø

S

W @

1:152

2

2

5

Ø

S

W

@

1

:

7

8

1

5

0

Ø

F

W

@

1

:

6

0

3

7

5

Ø

S

W

@

1

:

2

0

0

1

5

0

Ø

F

W

@

1

:

1

1

1

1

5

0

Ø

F

W

@

1

:

2

7

23.45

RIDGE

FFL=+19.11m

FFL=+18.60m

FSMH 2

CL=+ 18.60m

I.L=+16.32m

FSMH1

CL=+ 19.00m

I.L=+ 16.94m

SSMH1

CL=+ 19.00m

I.L=+17.24m

SSMH 2

CL=+ 18.60m

I.L=+16.62m

1

:

1

0

0

F

A

L

L

1

:

1

0

0

F

A

L

L

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ

SVP

SVP

SVP

SVP

SVP

SVP

SVP

SVP

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ

SVP

SVP

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ

SVP

SVP

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

IC

IC

IC

IC

AJ

AJ

AJ

AJ

IC

SVP

SVP

IC

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

SVP

SVP

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

SVP

SVP

IC

RG

I

LI

N

2

I

L

O

U

T

IL

IN

1

150Ø

F

W @

1:122

IL

IN

1

IL

O

U

T

3

0

0

Ø

S

W

@

1

:

1

4

8

IC

SW MH 2.1

CL=+19.94m

IL = +18.55 m

2

2

5

Ø

S

W

@

1

:

1

4

0

AJ

1

5

0

Ø

F

W

@

1

:

1

2

0

FW MH 2.0

CL= +19.90m

IL= +17.83m

SW MH 2.0

CL = +19.90m

IL

IN1

= +17.91m

IL

IN2

= +18.46m

IL

OUT

= +17.91m

I

L

I

N

2

I

L

I

N

1

I

L

O

U

T

SW MH 3.0

CL=+ 20.20m

IL = +17.80m

ATTENUATION TANK

CL = 'VARIES'

TL

T

= +19.03m

IL

T

= +17.83m

Storage Volume = 325m³

RG

RG

RG

RG

PETROL

INTERCEPTOR

IC

IC

IC

IC

IC

IC

IC

IC

2

2

5

Ø

S

W

@

1

:

3

5

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

DENOTES SITE BOUNDARY

NEW SURFACE WATER SEWER BY OTHER

NEW SURFACE WATER MANHOLE BY OTHER

NEW SURFACE WATER SEWER

NEW SURFACE WATER MANHOLE

NEW SURFACE WATER FLOW CONTROL MANHOLE

PROPOSED SURFACE WATER ACCESS JUNCTION

PROPOSED ROAD GULLY

PROPOSED PETROL INTERCEPTOR

PROPOSED ATTENUATION TANK

NEW FOUL WATER SEWER BY OTHER

NEW FOUL WATER MANHOLE BY OTHER

NEW FOUL WATER SEWER

NEW FOUL WATER MANHOLE

PROPOSED FOUL INSPECTION CHAMBER

PROPOSED FOUL ACCESS JUNCTION

AJ

RG

LEGEND:

SWMH 1.1 = MANHOLE NO.

CL = COVER LEVEL

IL = INVERT LEVEL

FWMH 1.1 = MANHOLE NO.

CL = COVER LEVEL

IL = INVERT LEVEL

IC

AJ

DEERPARK

ADARE

Co. LIMERICK

SOUTH SITE - PROPOSED FOUL & SURFACE WATER LAYOUTS

LIMERICK CITY & COUNTY COUNCIL

CITY HALL

MERCHANTS QUAY

LIMERICK

PLANNING

CONSULTING ENGINEERS & PROJECT MANAGERS

30 DRUMCONDRA ROAD UPPER

Tel: 061 310 701 (Limerick)

email: [email protected]

DRUMCONDRA

DUBLIN 9

web: www.dennanyreidy.ie

Tel: 01 216 2956 (Dublin)THE PARK

LORD EDWARD St.

LIMERICK

LIMERICK: DUBLIN:

V94 840C

D09 FT7K

DATE

REV. DESCRIPTION

PRODUCER

DATE

VERIFIER

DATE

APPROVER

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES UNLESS NOTED

OTHERWISE.

2. USE FIGURED DIMENSIONS ONLY. DO NOT SCALE.

3. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ENGINEER'S,

ARCHITECT'S AND SERVICE ENGINEER'S DRAWINGS AND SPECIFICATIONS.

4. ALL WORKS TO BE CARRIED OUT IN ACCORDANCE WITH CURRENT BUILDING

REGULATIONS.

1:250 @ A1

AD

JR

L200-150 B

A

COPYRIGHT AND OWNERSHIP OF THIS DRAWING IS VESTED IN DENNANY REIDY

ASSOCIATES LTD. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR

TRANSMITTED IN ANY FORM OR STORED IN ANY RETRIEVAL SYSTEM OF ANY

NATURE WITHOUT THE WRITTEN PERMISSION OF DENNANY REIDY ASSOCIATES

AS COPYRIGHT HOLDER EXCEPT AS AGREED FOR USE ON THE PROJECT FOR

WHICH THE DOCUMENT WAS ORIGINALLY ISSUED.

ALL RIGHT RESERVED BY THE LAW OF COPYRIGHT AND BY INTERNATIONAL

COPYRIGHT CONVENTIONS ARE RESERVED TO DENNANY REIDY ASSOCIATES LTD.

31/07/19

IRISH WATER STANDARD DETAILS AND CODE OF PRACTICE:

ALL OF THE SITE DRAINAGE WORKS SHOULD BE CARRIED OUT IN ACCORDANCE

WITH IRISH WATER'S (IW) "WASTEWATER INFRASTRUCTURE STANDARD DETAILS"

AND "CODE OF PRACTICE FOR WASTEWATER INFRASTRUCTURE".

FOR REINFORCED IN SITU ITEMS SUCH AS MANHOLES ETC, ALLOW H12

REBAR@200c/c BOTH FACES. NOTE THAT PRECAST OPTIONS ARE ALSO

SPECIFIED.

PIPE MATERIALS:

1. SERVICE CONNECTIONS FROM DWELLING TO BE 100mm Ø UNPLASTICISED

PVC IN ACCORDANCE WITH SECTION 3.13 OF IW CODE PRACTICE.

2. SITE SEWER TO BE THERMOPLASTIC STRUCTURED WALL PIPES IN

ACCORDANCE WITH SECTION 3.13 OF THE IW CODE OF PRACTICE.

TESTING:

1. SITE SEWER AND MANHOLES TO BE TESTED IN ACCORDANCE WITH

SECTION 4.10 OF IW CODE OF PRACTICE.

2. CCTV AND MANHOLE CONDITION SURVEYS TO BE CARRIED OUT IN

ACCORDANCE WITH SECTION 1.9 OF IW CODE OF PRACTICE IN ADVANCE OF

THE DEFECTS LIABILITY PERIOD.

NOTE: ALL MANHOLE COVER LEVELS TO BE CHECKED IN SITU TO ENSURE THAT

THEY ARE LEVEL WITH THE SURROUNDING FINISHED SURFACES.

22/08/19

A SURFACE WATER REVISED

CMcD AD JR

CMcD

CMcD

22/08/19 22/08/19

N

NE

E

SE

S

SW

W

NW

N

10/10/19

B GENERAL REVISIONS

CMcD AD JR

10/10/19 10/10/19

B

AutoCAD SHX Text
C
AutoCAD SHX Text
REV.
AutoCAD SHX Text
C
AutoCAD SHX Text
SCALES:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
PRODUCER:
AutoCAD SHX Text
VERIFIER:
AutoCAD SHX Text
APPROVER:
AutoCAD SHX Text
DRG. No.
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
DATE:
Page 2: SVP - Limerick · ilin2 scale proposed foul & surface water layouts 1:250 @ a1 150-fw mh 3.0 cl= +20.20m il= +17.71m sw mh 1.0 cl = +19.67m il = +18.10m sw mh 4.0 cl = +20.10m il

FFL=+8.66m

FFL=+9.00m

FSMH 10

DROP MH

CL =+13.10m

I.L.=+10.13m

I.L =+11.76m

FSMH 11

CL=+11.10m

IL= +9.80m

FSMH 12

CL =+11.40m

IL=+9.21m

SSMH 10

DROP MH

CL =+13.10m

I.L=+9.15m

I.L=+12.06m

1

:1

0

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:

1

6

F

A

L

L

1

:1

5

0

F

A

L

L

1

:

9

4

F

A

L

L

1:52 F

ALL

SSMH 11.3

CL=+ 11.20m

I.L=+ 8.54m

SSMH 11

CL= +12.48m

I.L =+8.08m

3

0

0

Ø

@

1

:2

0

0

F

A

L

L

1

:

1

5

0

F

A

L

L

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

SVP

SVP

AJ

AJ

AJ

AJ

AJ

IC

IC

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

IC

AJ

AJ

SVP

SVP

SVP

AJ

AJ

AJ

AJ

IC

RG

RG

RG

RG

RG

RG

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

225m

S

W

EX.SW MH

CL=+ 7.84m

I.L=+ 6.57m

EX.SW MH

CL=+ 7.31m

I.L=+ 6.27m

2

2

5

m

m

Ø

S

W

EX.FW MH

CL=+ 7.37m

I.L=+ 6.50m

1

0

0

m

m

Ø

F

W

EX.FW MH

CL=+ 7.87m

I.L=+ 6.79m

150Ø

F

W @

1:29 ( E

NC

AS

ED

IN

C

ON

CR

ET

E)

150Ø

F

W @

1:77 (E

NC

AS

ED

IN

C

ON

CR

ET

E)

1

5

0

Ø

F

W

@

1

:

4

5

(

E

N

C

A

S

E

D

I

N

C

O

N

C

R

E

T

E

)

FW MH 3.0

CL = +7.90m

IL = +7.00 m

1

0

0

m

m

Ø

F

W

AJ

SVP

AJ

IC

AJ

SVP AJ

AJ

AJ

IC

CO

NT

IN

UIT

Y LIN

E

X

3

0

0

Ø

@

1

:2

0

2

F

A

L

L

SW MH 1.0

CL=+12.23m

IL = +8.10m

AJ

AJ

2

2

5

Ø

S

W

@

1

:

1

0

4

2

2

5

Ø

S

W

@

1

:7

1

ATTENUATION

TANK

CL=+9.08m

ToT= +8.18m

IL = +7.33m

VOL= 30m³

ATTENUATION TANK

CL=+11.50m

ToT= +10.20m

IL = +8.21m

VOL= 203m³

RG

RG

RG

RG

RG

RG

RG

2

2

5

Ø

SSMH 12

DROP MH

CL=+11.20m

I.L=+ 7.89m

S14

CL=+ 9.01m

I.L =+7.48m

FW MH 2.0

CL = +8.44m

IL = +7.54m

SW MH 3.0

CL=+9.15m

IL = +7.33m

AJ

AJ

AJ

AJ

S13

CL=+ 9.15m

I.L=+ 7.62m

SW MH 2.0

CL=+11.20m

IL = +7.90m

SW MH 4.0

CL=+9.01m

IL =+7.26m

EX.SW MH 6.0

CL=+ 8.44m

I.L=+ 7.15m

SW FC MH 11.1

CL=+12.34m

IL = +8.12m

SW MH 11.2

CL=+11.50m

IL = +8.21m

PETROL

INTERCEPTOR

FW MH 1.0

CL = +8.95m

IL = +8.05m

SW FC MH

5.0

CL=+8.63m

IL =+7.20m

FFL=+11.4m

FFL=+11.3m

FFL=+11.1m

FFL=+11.3m

FFL=+8.6m

FFL=+8.80m

225Ø

S

W @

1:190

PETROL

INTERCEPTOR

FFL=+8.66m

FFL=+9.00m

FSMH 8

CL=+ 14.80m

I.L=+ 12.49m

FSMH 10

DROP MH

CL =+13.10m

I.L.=+10.13m

I.L =+11.76m

FSMH 11

CL=+11.10m

IL= +9.80m

FSMH 15

CL=+10.20m

IL =+8.16m

FSMH 9

CL=+13.20m

I.L=+12.09m

FSMH 12

CL =+11.40m

IL=+9.21m

FSMH 13

CL =+11.30m

I.L.=+8.675m

SSMH 8

CL=+14.80m

I.L=+ 12.79m

SS MH 9

CL=+ 13.20m

I.L=+12.39m

SSMH 10

DROP MH

CL =+13.10m

I.L=+9.15m

I.L=+12.06m

1:1

00 F

ALL

1:150 FALL

1:150 FALL

1:150 FALL

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:

1

6

F

A

L

L

1

:1

5

0

F

A

L

L

1

:9

4

F

A

L

L

1:5

2 F

AL

L

SSMH 11.3

CL=+ 11.20m

I.L=+ 8.54m

SSMH 11

CL= +12.48m

I.L =+8.08m

300Ø @

1:200 FALL

1

:

1

5

0

F

A

L

L

1:150 FALL

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

SVP

SVP

AJ

AJ

AJ

AJ

AJ

IC

IC

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

IC

AJ

AJ

SVP

SVP

SVP

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ AJ

IC

AJ

IC

SVP

SVP

SVP

SVP

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

225m

S

W

EX.SW MH

CL=+ 7.84m

I.L=+ 6.57m

2

2

5

m

m

Ø

S

W

EX.SW MH

CL=+ 7.31m

I.L=+ 6.27m

2

2

5

m

m

Ø

S

W

EX.FW MH

CL=+ 7.37m

I.L=+ 6.50m

1

0

0

m

m

Ø

F

W

1

0

0

m

m

Ø

F

W

EX.FW MH

CL=+ 7.87m

I.L=+ 6.79m

15

F

W @

1

:2

9 ( E

NC

AS

ED

IN

C

ON

CR

ET

E)

150Ø

F

W @

1:77 (E

NC

AS

ED

IN

C

ON

CR

ET

E)

1

5

0

Ø

F

W

@

1

:

4

5

(

E

N

C

A

S

E

D

I

N

C

O

N

C

R

E

T

E

)

FW MH 3.0

CL = +7.90m

IL = +7.00 m

1

0

0

m

m

Ø

F

W

AJ

SVP

AJ

IC

AJ

SVP AJ

AJ

AJ

IC

CO

NT

IN

UIT

Y L

IN

E

X

X

300Ø

@

1:202 FA

LL

SW MH 1.0

CL=+12.23m

IL = +8.10m

AJ

AJ

2

2

5

Ø

S

W

@

1

:

1

0

4

2

2

5

Ø

S

W

@

1

:7

1

ATTENUATION

TANK

CL=+9.08m

ToT= +8.18m

IL = +7.33m

VOL= 30m³

RG

RG

RG

RG

RG

RG

RG

RG

ATTENUATION TANK

CL=+11.50m

ToT= +10.20m

IL = +8.21m

VOL= 203m³

300Ø @

1:200 FALL

RG

RG

RG

RG

RG

RG

RG

RG

RG

2

2

5

Ø

SSMH 12

DROP MH

CL=+11.20m

I.L=+ 7.89m

S14

CL=+ 9.01m

I.L =+7.48m

FW MH 2.0

CL = +8.44m

IL = +7.54m

SW MH 3.0

CL=+9.15m

IL = +7.33m

AJ

AJ

AJ

AJ

S13

CL=+ 9.15m

I.L=+ 7.62m

SW MH 2.0

CL=+11.20m

IL = +7.90m

FSMH 14

CL=+10.60m

IL =+8.31m

1:150 FALL

SSMH 11.5

C.L=+10.65m

IL=+9.32m

SW MH 4.0

CL=+9.01m

IL =+7.26m

EX.SW MH 6.0

CL=+ 8.44m

I.L=+ 7.15m

SW FC MH 11.1

CL=+12.34m

IL = +8.12m

SW MH 11.2

CL=+11.50m

IL = +8.21m

PETROL

INTERCEPTOR

FW MH 1.0

CL = +8.95m

IL = +8.05m

SW FC MH

5.0

CL=+8.63m

IL =+7.20m

FFL=+11.8m

FFL=+11.5m

FFL=+11.4m

FFL=+11.3m

FFL=+11.1m

FFL=+11.3m

FFL=+8.6m

FFL=+8.80m

SSMH 11.4

CL=+11.50m

I.L=+8.98m

225Ø @

1:200 (ENCASED IN CONCRETE)

22

S

W @

1

:1

90

PETROL

INTERCEPTOR

DENOTES SITE BOUNDARY

NEW SURFACE WATER SEWER BY OTHER

NEW SURFACE WATER MANHOLE BY OTHER

EXISTING SURFACE WATER SEWER

NEW SURFACE WATER SEWER

NEW SURFACE WATER MANHOLE

NEW FLOW CONTROL DEVICE MANHOLE

PROPOSED SURFACE WATER ACCESS JUNCTION

PROPOSED ROAD GULLY

PETROL INTERCEPTOR

ATTENUATION TANK

EXISTING FOUL WATER SEWER

NEW FOUL WATER SEWER BY OTHER

NEW FOUL WATER MANHOLE BY OTHER

PROPOSED FOUL WATER SEWER

PROPOSED FOUL WATER MANJOLE

PROPOSED FOUL INSPECTION CHAMBER

PROPOSED FOUL ACCESS JUNCTION

AJ

RG

LEGEND:

IC

AJ

REV. DESCRIPTION

DATE

30 DRUMCONDRA RD UPPER

email: [email protected]

DRUMCONDRA

DUBLIN 9

web: www.dennanyreidy.ie

THE PARK

LORD EDWARD St.

LIMERICK

CONSULTING ENGINEERS & PROJECT MANAGERS

PLANNING

V94 840C D09 FT7K

PRODUCER VERIFIER APPROVER

DATE DATE

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES UNLESS

NOTED OTHERWISE.

2. USE FIGURED DIMENSIONS ONLY. DO NOT SCALE.

3. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ENGINEER'S,

ARCHITECT'S AND SERVICE ENGINEER'S DRAWINGS AND SPECIFICATIONS.

4. ALL WORKS TO BE CARRIED OUT IN ACCORDANCE WITH CURRENT BUILDING

REGULATIONS.

Tel: 01 216 2956 (Dublin)

Tel: 061 310 701 (Limerick)

LIMERICK: DUBLIN:

COPYRIGHT AND OWNERSHIP OF THIS

DRAWING IS VESTED IN DENNANY REIDY

ASSOCIATES LTD. NO PART OF THIS

DOCUMENT MAY BE REPRODUCED OR

TRANSMITTED IN ANY FORM OR STORED IN

ANY RETRIEVAL SYSTEM OF ANY NATURE

WITHOUT THE WRITTEN PERMISSION OF

DENNANY REIDY ASSOCIATES AS

COPYRIGHT HOLDER EXCEPT AS AGREED

FOR USE ON THE PROJECT FOR WHICH THE

DOCUMENT WAS ORIGINALLY ISSUED.

ALL RIGHT RESERVED BY THE LAW OF

COPYRIGHT AND BY INTERNATIONAL

COPYRIGHT CONVENTIONS ARE RESERVED

TO DENNANY REIDY ASSOCIATES LTD.

B

B

IRISH WATER STANDARD DETAILS AND CODE PRACTICE:

ALL OF THE SITE DRAINAGE WORKS SHOULD BE CARRIED OUT IN ACCORDANCE

WITH IRISH WATER'S (IW) "WASTEWATER INFRASTRUCTURE STANDARD DETAILS"

AND "CODE OF PRACTICE FOR WASTEWATER INFRASTRUCTURE".

FOR REINFORCED IN SITU ITEMS SUCH AS MANHOLES ETC, ALLOW H12

REBAR@200c/c BOTH FACES. NOTE THAT PRECAST OPTIONS ARE ALSO

SPECIFIED.

PIPE MATERIALS:

1. SERVICE CONNECTIONS FROM DWELLING TO BE 100mm Ø UNPLASTICISED

PVC IN ACCORDANCE WITH SECTION 3.13 OF IW CODE PRACTICE.

2. SITE SEWER TO BE THERMOPLASTIC STRUCTURED WALL PIPES IN

ACCORDANCE WITH SECTION 3.13 OF THE IW CODE OF PRACTICE.

TESTING:

1. SITE SEWER AND MANHOLES TO BE TESTED IN ACCORDANCE WITH

SECTION 4.10 OF IW CODE OF PRACTICE.

2. CCTV AND MANHOLE CONDITION SURVEYS TO BE CARRIED OUT IN

ACCORDANCE WITH SECTION 1.9 OF IW CODE OF PRACTICE IN ADVANCE OF

THE DEFECTS LIABILITY PERIOD.

NOTE: ALL MANHOLE COVER LEVELS TO BE CHECKED IN SITU TO ENSURE THAT

THEY ARE LEVEL WITH THE SURROUNDING FINISHED SURFACES.

N

NE

E

SE

S

SW

W

NW

N

SCALE

PROPOSED FOUL & SURFACE WATER LAYOUTS- DWG 1 OF 2

1:250 @ A1

-

151

L200-151

L200-152

SCALE

KEY PLAN

1:250 @ A1

-

151

DEERPARK

ADARE,

Co. LIMERICK

NORTH SITE - PROPOSED FOUL & SURFACE WATER LAYOUTS-DWG 1 OF 2

LIMERICK CITY & COUNTY COUNCIL

CITY HALL

MERCHANTS QUAY,LIMERICK

1:250 @ A103/10/19

CMcD

LG

CMcD

AD

L200-151

AGENERAL REVISION

08/10/19

STR CMCD AD

08/10/19 08/10/19

BGENERAL REVISION

11/10/19

STR CMCD AD

11/10/19 11/10/19

AutoCAD SHX Text
9.36
AutoCAD SHX Text
REV.
AutoCAD SHX Text
SCALES:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
PRODUCER:
AutoCAD SHX Text
VERIFIER:
AutoCAD SHX Text
APPROVER:
AutoCAD SHX Text
DWG. No.
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
C
AutoCAD SHX Text
C
Page 3: SVP - Limerick · ilin2 scale proposed foul & surface water layouts 1:250 @ a1 150-fw mh 3.0 cl= +20.20m il= +17.71m sw mh 1.0 cl = +19.67m il = +18.10m sw mh 4.0 cl = +20.10m il

FSMH 15

CL=+10.20m

IL =+8.16m

FSMH 12

CL =+11.40m

IL=+9.21m

FSMH 13

CL =+11.30m

I.L.=+8.675m

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

SVP

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJAJ

IC

AJ

IC

SVP

SVP

SVP

SVP

RG

RG

RG

RG

RG

RG

RG

RG

RG

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

CO

NT

IN

UIT

Y LIN

E

X

X

RG

RG

RG

RG

RG

RG

RG

RG

3

0

0

Ø

@

1

:2

0

0

F

A

L

L

RG

RG

FSMH 14

CL=+10.60m

IL =+8.31m

1:150 FALL

SSMH 11.5

C.L=+10.65m

IL=+9.32m

FFL=+11.8m

FFL=+11.5m

SSMH 11.4

CL=+11.50m

I.L=+8.98m

2

2

5

Ø

@

1

:2

0

0

(E

N

C

A

S

E

D

IN

C

O

N

C

R

E

T

E

)

DENOTES SITE BOUNDARY

NEW SURFACE WATER SEWER BY OTHER

NEW SURFACE WATER MANHOLE BY OTHER

EXISTING SURFACE WATER SEWER

NEW SURFACE WATER SEWER

NEW SURFACE WATER MANHOLE

NEW FLOW CONTROL DEVICE MANHOLE

PROPOSED SURFACE WATER ACCESS JUNCTION

PROPOSED ROAD GULLY

PETROL INTERCEPTOR

ATTENUATION TANK

EXISTING FOUL WATER SEWER

NEW FOUL WATER SEWER BY OTHER

NEW FOUL WATER MANHOLE BY OTHER

PROPOSED FOUL WATER SEWER

PROPOSED FOUL WATER MANJOLE

PROPOSED FOUL INSPECTION CHAMBER

PROPOSED FOUL ACCESS JUNCTION

AJ

RG

LEGEND:

IC

AJ

FFL=+8.66m

FFL=+9.00m

FSMH 8

CL=+ 14.80m

I.L=+ 12.49m

FSMH 10

DROP MH

CL =+13.10m

I.L.=+10.13m

I.L =+11.76m

FSMH 11

CL=+11.10m

IL= +9.80m

FSMH 15

CL=+10.20m

IL =+8.16m

FSMH 9

CL=+13.20m

I.L=+12.09m

FSMH 12

CL =+11.40m

IL=+9.21m

FSMH 13

CL =+11.30m

I.L.=+8.675m

SSMH 8

CL=+14.80m

I.L=+ 12.79m

SS MH 9

CL=+ 13.20m

I.L=+12.39m

SSMH 10

DROP MH

CL =+13.10m

I.L=+9.15m

I.L=+12.06m

1:1

00 F

ALL

1:150 FALL

1:150 FALL

1:150 FALL

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:1

5

0

F

A

L

L

1

:

1

6

F

A

L

L

1

:1

5

0

F

A

L

L

1

:9

4

F

A

L

L

1:5

2 F

AL

L

SSMH 11.3

CL=+ 11.20m

I.L=+ 8.54m

SSMH 11

CL= +12.48m

I.L =+8.08m

300Ø @

1:200 FALL

1

:

1

5

0

F

A

L

L

1:150 FALL

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

SVP

SVP

AJ

AJ

AJ

AJ

AJ

IC

IC

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

IC

AJ

AJ

SVP

SVP

SVP

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

IC

AJ

AJ

AJ

IC

AJ

AJ

AJ

AJ

AJ

AJ

AJ AJ

IC

AJ

IC

SVP

SVP

SVP

SVP

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

RG

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

AJ

225m

S

W

EX.SW MH

CL=+ 7.84m

I.L=+ 6.57m

2

2

5

m

m

Ø

S

W

EX.SW MH

CL=+ 7.31m

I.L=+ 6.27m

2

2

5

m

m

Ø

S

W

EX.FW MH

CL=+ 7.37m

I.L=+ 6.50m

1

0

0

m

m

Ø

F

W

1

0

0

m

m

Ø

F

W

EX.FW MH

CL=+ 7.87m

I.L=+ 6.79m

15

F

W @

1

:2

9 ( E

NC

AS

ED

IN

C

ON

CR

ET

E)

150Ø

F

W @

1:77 (E

NC

AS

ED

IN

C

ON

CR

ET

E)

1

5

0

Ø

F

W

@

1

:

4

5

(

E

N

C

A

S

E

D

I

N

C

O

N

C

R

E

T

E

)

FW MH 3.0

CL = +7.90m

IL = +7.00 m

1

0

0

m

m

Ø

F

W

AJ

SVP

AJ

IC

AJ

SVP AJ

AJ

AJ

IC

CO

NT

IN

UIT

Y L

IN

E

X

X

300Ø

@

1:202 FA

LL

SW MH 1.0

CL=+12.23m

IL = +8.10m

AJ

AJ

2

2

5

Ø

S

W

@

1

:

1

0

4

2

2

5

Ø

S

W

@

1

:7

1

ATTENUATION

TANK

CL=+9.08m

ToT= +8.18m

IL = +7.33m

VOL= 30m³

RG

RG

RG

RG

RG

RG

RG

RG

ATTENUATION TANK

CL=+11.50m

ToT= +10.20m

IL = +8.21m

VOL= 203m³

300Ø @

1:200 FALL

RG

RG

RG

RG

RG

RG

RG

RG

RG

2

2

5

Ø

SSMH 12

DROP MH

CL=+11.20m

I.L=+ 7.89m

S14

CL=+ 9.01m

I.L =+7.48m

FW MH 2.0

CL = +8.44m

IL = +7.54m

SW MH 3.0

CL=+9.15m

IL = +7.33m

AJ

AJ

AJ

AJ

S13

CL=+ 9.15m

I.L=+ 7.62m

SW MH 2.0

CL=+11.20m

IL = +7.90m

FSMH 14

CL=+10.60m

IL =+8.31m

1:150 FALL

SSMH 11.5

C.L=+10.65m

IL=+9.32m

SW MH 4.0

CL=+9.01m

IL =+7.26m

EX.SW MH 6.0

CL=+ 8.44m

I.L=+ 7.15m

SW FC MH 11.1

CL=+12.34m

IL = +8.12m

SW MH 11.2

CL=+11.50m

IL = +8.21m

PETROL

INTERCEPTOR

FW MH 1.0

CL = +8.95m

IL = +8.05m

SW FC MH

5.0

CL=+8.63m

IL =+7.20m

FFL=+11.8m

FFL=+11.5m

FFL=+11.4m

FFL=+11.3m

FFL=+11.1m

FFL=+11.3m

FFL=+8.6m

FFL=+8.80m

SSMH 11.4

CL=+11.50m

I.L=+8.98m

225Ø @

1:200 (ENCASED IN CONCRETE)

225Ø

S

W @

1

:190

PETROL

INTERCEPTOR

DEERPARK

ADARE

Co. LIMERICK

NORTH SITE - PROPOSED FOUL & SURFACE WATER LAYOUTS- DWG 2 OF 2

LIMERICK CITY & COUNTY COUNCIL

CITY HALL

MERCHANTS QUAY

LIMERICK

PLANNING

CONSULTING ENGINEERS & PROJECT MANAGERS

30 DRUMCONDRA ROAD UPPER

Tel: 061 310 701 (Limerick)

email: [email protected]

DRUMCONDRA

DUBLIN 9

web: www.dennanyreidy.ie

Tel: 01 216 2956 (Dublin)THE PARK

LORD EDWARD St.

LIMERICK

LIMERICK: DUBLIN:

V94 840C

D09 FT7K

DATE

REV. DESCRIPTION

PRODUCER

DATE

VERIFIER

DATE

APPROVER

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS IN METRES UNLESS NOTED

OTHERWISE.

2. USE FIGURED DIMENSIONS ONLY. DO NOT SCALE.

3. DRAWINGS TO BE READ IN CONJUNCTION WITH ALL RELEVANT ENGINEER'S,

ARCHITECT'S AND SERVICE ENGINEER'S DRAWINGS AND SPECIFICATIONS.

4. ALL WORKS TO BE CARRIED OUT IN ACCORDANCE WITH CURRENT BUILDING

REGULATIONS.

1:250 @ A1

L200-152 A

A

COPYRIGHT AND OWNERSHIP OF THIS DRAWING IS VESTED IN DENNANY REIDY

ASSOCIATES LTD. NO PART OF THIS DOCUMENT MAY BE REPRODUCED OR

TRANSMITTED IN ANY FORM OR STORED IN ANY RETRIEVAL SYSTEM OF ANY

NATURE WITHOUT THE WRITTEN PERMISSION OF DENNANY REIDY ASSOCIATES

AS COPYRIGHT HOLDER EXCEPT AS AGREED FOR USE ON THE PROJECT FOR

WHICH THE DOCUMENT WAS ORIGINALLY ISSUED.

ALL RIGHT RESERVED BY THE LAW OF COPYRIGHT AND BY INTERNATIONAL

COPYRIGHT CONVENTIONS ARE RESERVED TO DENNANY REIDY ASSOCIATES LTD.

03/10/19

IRISH WATER STANDARD DETAILS AND CODE PRACTICE:

ALL OF THE SITE DRAINAGE WORKS SHOULD BE CARRIED OUT IN ACCORDANCE

WITH IRISH WATER'S (IW) "WASTEWATER INFRASTRUCTURE STANDARD DETAILS"

AND "CODE OF PRACTICE FOR WASTEWATER INFRASTRUCTURE".

FOR REINFORCED IN SITU ITEMS SUCH AS MANHOLES ETC, ALLOW H12

REBAR@200c/c BOTH FACES. NOTE THAT PRECAST OPTIONS ARE ALSO

SPECIFIED.

PIPE MATERIALS:

1. SERVICE CONNECTIONS FROM DWELLING TO BE 100mm Ø UNPLASTICISED

PVC IN ACCORDANCE WITH SECTION 3.13 OF IW CODE PRACTICE.

2. SITE SEWER TO BE THERMOPLASTIC STRUCTURED WALL PIPES IN

ACCORDANCE WITH SECTION 3.13 OF THE IW CODE OF PRACTICE.

TESTING:

1. SITE SEWER AND MANHOLES TO BE TESTED IN ACCORDANCE WITH

SECTION 4.10 OF IW CODE OF PRACTICE.

2. CCTV AND MANHOLE CONDITION SURVEYS TO BE CARRIED OUT IN

ACCORDANCE WITH SECTION 1.9 OF IW CODE OF PRACTICE IN ADVANCE OF

THE DEFECTS LIABILITY PERIOD.

NOTE: ALL MANHOLE COVER LEVELS TO BE CHECKED IN SITU TO ENSURE THAT

THEY ARE LEVEL WITH THE SURROUNDING FINISHED SURFACES.

CMcD

LG

AD

CMcD

N

NE

E

SE

S

SW

W

NW

N

SCALE

PROPOSED FOUL & SURFACE WATER LAYOUTS- DWG 2 OF 2

1:250 @ A1

-

152

L200-151

L200-152

SCALE

KEY PLAN

1:250 @ A1

-

152

AGENERAL REVISION

11/10/19

STR CMCD AD

11/10/19 11/10/19

AutoCAD SHX Text
9.36
AutoCAD SHX Text
C
AutoCAD SHX Text
REV.
AutoCAD SHX Text
C
AutoCAD SHX Text
SCALES:
AutoCAD SHX Text
DESIGNER:
AutoCAD SHX Text
PRODUCER:
AutoCAD SHX Text
VERIFIER:
AutoCAD SHX Text
APPROVER:
AutoCAD SHX Text
DRG. No.
AutoCAD SHX Text
CLIENT:
AutoCAD SHX Text
PROJECT:
AutoCAD SHX Text
TITLE:
AutoCAD SHX Text
REVISIONS:
AutoCAD SHX Text
DATE: