test report emc - rainbowrainbow.com.ua/images/rlight/xitanium-40w-0.35a-115v...report no.:...

7
Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment Co., Ltd. Lighting EMC Laboratory Bld. 9, Lane 888 Tianlin Road Shanghai Business Park, 200233 SHANGHAI Tel.: +86 21 24128344 FAX.: +86 21 54452270 E-mail: [email protected] Equipment under Test: Applicant: Philips (China) investment Co., Ltd.; #9, Lane 888 Tianlin Road Shanghai Business Park, 200233 SHANGHAI Manufacturer: Philips (China) investment Co., Ltd.; #9, Lane 888 Tianlin Road Shanghai Business Park, 200233 SHANGHAI EUT: Electronic Ballast Brand/model: Xitanium 40W 0.35A 115V 230V 10NC:9290 014 029 EUT received: 2015-04-07 Information concerning the Test report: Report number: 2015A0265 Contact: Mr. Mao, Xiaojun Tel.: +86 21 24128344 FAX.: +86 21 54452270 E-mail: [email protected] Applied standards: German Standard European Standard IEC/CISPR-Standard DIN EN 55015:2014-03 EN 55015:2013 CISPR 15:2013 + IS1:2013 + IS2:2013 DIN EN55015:2009-11 EN 55015:2006 + A1:2007 + A2:2009 CISPR 15:2005 + A1:2006 + A2:2008 DIN EN 61547:2010-03 EN 61547:2009 IEC 61547:2009 DIN EN 61000-3-2:2010-03 EN 61000-3-2:2006 + A1:2009 + A2:2009 IEC 61000-3-2:2005 + A1:2008 + A2:2009 DIN EN 61000-3-3:2014-03 EN 61000-3-3:2013 IEC 61000-3-3:2013 DIN EN 61000-3-3:2009-06 EN 61000-3-3:2008 IEC 61000-3-3:2008 Remarks to the Standards: None Result: Pass Date of issue: 2015-05-11 Tested by: Mr Yuan Yu Mr. ZhouWeiping Reviewed: Mr. Mao, Xiaojun

Upload: others

Post on 06-Apr-2020

17 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Test Report EMC - Rainbowrainbow.com.ua/images/RLight/Xitanium-40W-0.35A-115V...Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment

Report No.: 2015A0265

06-999-1110-01 Page 1 of 48

Test Report EMC

Test Laboratory:

Philips (China) investment Co., Ltd. Lighting EMC Laboratory Bld. 9, Lane 888 Tianlin Road

Shanghai Business Park, 200233 SHANGHAI Tel.: +86 21 24128344 FAX.: +86 21 54452270 E-mail: [email protected]

Equipment under Test:

Applicant: Philips (China) investment Co., Ltd.; #9, Lane 888 Tianlin Road Shanghai Business Park, 200233 SHANGHAI

Manufacturer: Philips (China) investment Co., Ltd.; #9, Lane 888 Tianlin Road Shanghai Business Park, 200233 SHANGHAI

EUT: Electronic Ballast

Brand/model: Xitanium 40W 0.35A 115V 230V 10NC:9290 014 029

EUT received: 2015-04-07

Information concerning the Test report:

Report number: 2015A0265

Contact: Mr. Mao, Xiaojun Tel.: +86 21 24128344 FAX.: +86 21 54452270 E-mail: [email protected]

Applied standards:

German Standard European Standard IEC/CISPR-Standard DIN EN 55015:2014-03 EN 55015:2013 CISPR 15:2013 + IS1:2013 +

IS2:2013 DIN EN55015:2009-11 EN 55015:2006 + A1:2007 +

A2:2009 CISPR 15:2005 + A1:2006 + A2:2008

DIN EN 61547:2010-03 EN 61547:2009 IEC 61547:2009 DIN EN 61000-3-2:2010-03 EN 61000-3-2:2006 + A1:2009 +

A2:2009 IEC 61000-3-2:2005 + A1:2008 + A2:2009

DIN EN 61000-3-3:2014-03 EN 61000-3-3:2013 IEC 61000-3-3:2013 DIN EN 61000-3-3:2009-06 EN 61000-3-3:2008 IEC 61000-3-3:2008

Remarks to the Standards: None

Result: Pass

Date of issue: 2015-05-11

Tested by:

Mr Yuan Yu

Mr. ZhouWeiping

Reviewed:

Mr. Mao, Xiaojun

Page 2: Test Report EMC - Rainbowrainbow.com.ua/images/RLight/Xitanium-40W-0.35A-115V...Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment

Report No.: 2015A0265

06-999-1110-01 Page 7 of 48

5 Test and measuring results

5.1 Disturbance voltage

5.1.1 EN 55015 Disturbance voltage (9 kHz - 30 MHz) at power input

General information about the Test:

Tested by: Mr. Yuan Yu

Test date: 2015-05-06

Instruments: Test site for luminaries Inventory number Description Manufacturer Type

RD-15-0060 EMI Receiver Rohde & Schwarz ESR7 RD-04-0125 Power Source KIKUSUI PCR1000CA RD-18-0027 LISN (for DC Measurement) Schwarzbeck NSLK 8127

Environmental conditions: Rated value Measured value

Ambient temperature: 15 - 25 °C 24 °C

Information concerning the Test:

Test set-up: DIN EN 55015, Clause 8 For built-in appliances the Technical Report CISPR 30(-1 for fluo; -2 for HID)

Operating mode: 1,2

Result: pass

Protocol: See next pages

Page 3: Test Report EMC - Rainbowrainbow.com.ua/images/RLight/Xitanium-40W-0.35A-115V...Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment

Report No.: 2015A0265

06-999-1110-01 Page 12 of 48

Philips Lighting Standard Testing Laboratory RFI Voltage Test at Mains Input

Manufacture: Philips Lighting Electronics Test date. 06-May-2015

Test Spec: CISPR15/EN55015 EUT Xitanium 40W 0.35A 115V 230V

Phase L Control number: LED-2015-0164-02

Operating mode: 230V/50Hz Operator: Yuan Yu

Comment: With CertaFlux 1550 + CertaFlux 2200, 88V output

Scan setting:

Frequency Receiver setting

Start Stop Step IF BW detector Meas-time Atten Preamp OpRge

9KHz 150KHz 50Hz 200Hz QP+AV 2 Sec Auto OFF 60dB

150KHz 30MHz 2.25KHz 9KHz QP+AV 2 Sec Auto OFF 60dB

100 kHz 1 MHz 10 MHz9 kHz 30 MHz

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

100.0

110.0

0.0

120.0

dBμV

Limits

55015MQP

55015MAV

Transducer

8121

Traces

QP

AV

Peak Search Results

Trace Frequency Level Limit Delta Limit Delta Ref Comment

(MHz) (dBμV) (dBμV) (dB) (dB)

* = limit exceeded

Page 4: Test Report EMC - Rainbowrainbow.com.ua/images/RLight/Xitanium-40W-0.35A-115V...Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment

Report No.: 2015A0265

06-999-1110-01 Page 20 of 48

5.2 Radiated Magnetic field strength (9 kHz - 30 MHz)

General information about the Test:

Tested by: Mr. Xu Zhongwei

Test date: 2015-05-06

Instruments: Test site for luminaries Inventory number Description Manufacturer Type

RD-15-0060 EMI Receiver Rohde & Schwarz ESR7 RD-04-0125 Power Source KIKUSUI PCR1000CA RD-08-0352 Large loop Antenna SCHWARZBECK HXYZ9170

Environmental conditions: Rated value Measured value

Ambient temperature: 15 - 25 °C 23 - 25 °C

Information concerning the Test:

Test set-up: The device is located at the centre of a 2 m 3-Loop antenna. For built-in appliances the Technical Report CISPR 30(-1 for fluo; -2 for HID)

Operating mode: 1,2

Result: pass

Protocol: See next pages…

Page 5: Test Report EMC - Rainbowrainbow.com.ua/images/RLight/Xitanium-40W-0.35A-115V...Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment

Report No.: 2015A0265

06-999-1110-01 Page 21 of 48

Standard Testing Laboratory Radiated Magnetic Field Strength(Loop Antenna)

Manufacture: Philips Lighting Electronics Test Date 06-May-2015

Test Spec: CISPR15/EN55015 EUT Xitanium 40W 0.35A 115V 230V

Antenna X Control number: LED-2015-0164-01

Operating mode: 230V/50Hz Operator: Xu Zhongwei

Comment: With CertaFlux 1550 + CertaFlux 2200, 88V output

Scan setting:

Frequency Receiver setting

Start Stop Step IF BW detector Meas-time Atten Preamp OpRge

9KHz 150KHz 100Hz 200Hz PK 20ms Auto OFF 60dB

150KHz 30MHz 5KHz 9KHz PK 5ms Auto OFF 60dB

100 kHz 1 MHz 10 MHz9 kHz 30 MHz

-20.0

-10.0

0.0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

-30.0

100.0

dBμA

Limits

LLA

Transducer

LLA

Traces

PK+

Page 6: Test Report EMC - Rainbowrainbow.com.ua/images/RLight/Xitanium-40W-0.35A-115V...Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment

Report No.: 2015A0265

06-999-1110-01 Page 27 of 48

5.3 EN 55015 RF Emission in the frequency range 30 MHz - 300 MHz

Selected measurement method for RF disturbances in the frequency range from 30 to 300 MHz

x CDN-method according to Annex B of DIN EN55015

Antenna-method according to CISPR 22 clause 10

Remarks to the CDN Method:

If the lighting equipment complies with the requirements of Annex B of EN55015, it is deemed to comply with the limits of the sub clause 4.4.2 Table 3b - Radiated RF disturbances limits in the frequency range 30 – 300 MHz.

5.3.1 EN 55015 RF Emission in the frequency range 30 MHz - 300 MHz (CDN-Method)

General information about the Test:

Tested by: Mr. Yuan Yu

Test date: 2015-05-06

Instruments: Inventory number Description Manufacturer Type

RD-15-0060 EMI Receiver Rohde & Schwarz ESR7

RD-04-0125 Power Source KIKUSUI PCR1000CA

CDN / Clamps: Inventory number Description Manufacturer Type

RD-09-0113 CDN TESEQ CDNE310 RD-17-0005-4 CDN schaffner CDN A201

Environmental conditions: Rated value Measured value

Ambient temperature: 15 - 25 °C 23 - 25 °C

Information concerning the Test:

Test set-up: The EUT was tested as part of the reference luminaire in accordance with CISPR 30The test setup was make according to the decriptions of Annex B in EN 55015

Operating mode: 1,2,

Result: pass

Protocol: Next pages

Page 7: Test Report EMC - Rainbowrainbow.com.ua/images/RLight/Xitanium-40W-0.35A-115V...Report No.: 2015A0265 06-999-1110-01 Page 1 of 48 Test Report EMC Test Laboratory: Philips (China) investment

Report No.: 2015A0265

06-999-1110-01 Page 28 of 48

Philips Lighting Standard Testing Laboratory RF Emission in Frequency range 30MHz-300MHz(CDN method)

Manufacture: Philips Lighting Electronics Test date 06-May-2015

Test Spec: CISPR15/EN55015 EUT Xitanium 40W 0.35A 115V 230V

Operating mode: 230V/50Hz Control number: LED-2015-0164-01

Comment: With CertaFlux 1550 + CertaFlux 2200, 88V output

Operator: Yuan Yu

Scan setting:

Frequency Receiver setting

Start Stop Step IF BW detector Meas-time Atten Preamp OpRge

30MHHz 300MHz 30KHz 120KHz QP 2 Sec Auto OFF 60dB

100 MHz30 MHz 300 MHz

20.0

30.0

40.0

50.0

60.0

70.0

80.0

10.0

90.0

dBμV

Limits

Bersier

Transducer

M301 28

Traces

QP

Peak Search Results

Trace Frequency Level Limit Delta Limit Delta Ref Comment

(MHz) (dBμV) (dBμV) (dB) (dB)

* = limit exceeded