tp vega telenor ran qabw01 tss ran tssr 20130506-v2.2

59
Telenor Vega Project Site ID: QABW01 Site Name: QABW01 Site Type GF City/town: Goth-Abdul-Wahid-Surki District: Goth-Abdul-Wahid-Surki Site Address: Surveyor: Irfan Ali Tel: 0344-4447691 Survey Date: 07-Mar-13 ZTE Submitter Telenor Receiver Telenor Approv Name: Name: Name: Date: Date: Date: TECHNICAL SITE SURVEY REPORT(V2.2) Tappoo Garhi Hassan Sarki, Deh. Hanbhi,Taluka Thul District Jaccobabad.

Upload: tonygrt12

Post on 10-Nov-2015

243 views

Category:

Documents


3 download

DESCRIPTION

FA CW BOQ

TRANSCRIPT

Cover

Telenor Vega Project

TECHNICAL SITE SURVEY REPORT(V2.2)

Site ID:QABW01Site Name:QABW01Site TypeGFCity/town:Goth-Abdul-Wahid-SurkiDistrict:Goth-Abdul-Wahid-SurkiSite Address:Tappoo Garhi Hassan Sarki, Deh. Hanbhi,Taluka Thul District Jaccobabad.

Surveyor:Irfan AliTel:0344-4447691Survey Date: 07-Mar-13

ZTE SubmitterTelenor ReceiverTelenor Approver

Name:Name:Name:Date:Date:Date:

Existing InfoTechnical Site Survey Report Telenor Vega ProjectQtySurvey ItemExisting InformationTipsSite Basic Information1Site ID:QABW012Site Name:QABW013RF Configuration for 900Mhz-ExistingS3/2/2/Automatically generated 4RF Configuration for 1800Mhz-ExistingS2/2//Automatically generated 5City/town:Goth-Abdul-Wahid-Surki6District:Goth-Abdul-Wahid-Surki7Survey Date: 7/Mar/138Longitude(E):68.73699Latitude(N):28.326410Site LocationCity11Elevation (m):6512Site Type:GFGreenfield Site or Rooftop Site13Hub/Normal/BSC/CoreNormal14Site type (equipment location):Outdoor Pad15Building Height(m):16Site Category:MacroMacro, Micro or TXN Repeater17Tower propertyTP BulidTP Build, TP Guest or Authority18Host OperatorTP19Number of sharing parties020Tower Type:3-legs Tower21Tower/Pole MaterialTube Tower22Tower Height(m):4523Tower PaintNO24Tower grounding providedYES25Fall Arrest System (Cage / Anti Glide lock System)YES26Air Craft Warning Light installedYES27Fire Panel InstallationYES28Boundary/Wall Fence TypeBoundary29Site SecuritySecurity Guard/Remotely Monitored30Site Address:Tappoo Garhi Hassan Sarki, Deh. Hanbhi,Taluka Thul District Jaccobabad.Site Access Information1Site Access24hrs2Night access possibleYes3Land Owner IssueNo4Land Owner Name5Contact Number for Site Access6Special Access PermissionsNo7Society issueNo8Special Key needed?No9Crane needed10Width of stairsonly for rooftop sites11RemarkExisting AC Informaiton1Independent TransformerNO2Sanctioned Load (KW)Allowed maximum power could be used for site3Existing IPS TypeN/AIf no IPS, please choose N/A4Existing ATS TypeN/AIf no ATS, please choose N/A5Existing ACDB TypeN/AIf no ACDB, please choose N/A6AC PowerThree phase7Surge Arrestor Installed YES8Surge Arrestor Rating(kA)409Main Breaker Capacity63A10Total service breakers111Rating of transformer(KVA)12AC cable size 16mmFrom MCB to ACDB/IPS/ATS13AC cable Length(m)1314Spare socket Qty.015Spare service breakers016Current Load(A)4.2A17Current Load(B)6.1A18Current Load(C)5.4A19Rating of ATS/IPS KVA20RemarkExisting Grounding Information1Numbers of earthing Pit2Grounding Resistance Pit1 (ohm)3.93Grounding Resistance Pit2 (ohm)If there are more separated Pit. 4RemarkAnything else to recordExisting Genset Information1Existing GensetAvailableonly for TP Genset2Genset ModelSiemensonly for TP Genset3Genset Qty1only for TP Genset4Genset Capacity(KVA)11only for TP fuel tank5Existing fuel tankAvailableonly for TP fuel tank6Fuel tank Capacity(L)600only for TP fuel tankExiting Rec.Rec. Type 11DC System ManufacturerELTEK Rectifier installed(OD)2Rec. Model.Eltek FP2 2000[New Rectifier]3Service Rectifier Module44Spare Module Slots45Each Module Capacity2000W6Total DC Breakers147Spare DC Breakers38Output Voltage51V9DC Total Capacity8000W10Spare socket Qty.211Current Loadind26.3A12Spare Space Inside of Rec.(U)2URec. Type 21DC System Manufacturer2Rec. Model.3Service Rectifier Module4Spare Module Slots5Each Module Capacity6Total DC Breakers7Spare DC Breakers8Output Voltage9DC Total Capacity10Spare socket Qty.11Current Loadind12Spare Space Inside of Rec.(U)13RemarkExisting Battery Information Battery Type 11Battery ModelZTE BatteryIf the Cabinet not open, no need fill in this information2Battery Group Quantity(0,1,2,3)1If the Cabinet not open, no need fill in this information3Battery Type(2v,12v)2vIf the Cabinet not open, no need fill in this information4Battery Capacity of Each GroupIf the Cabinet not open, no need fill in this information5Battery InstallationOutdoor Battery CabinetBattery Type 21Battery ModelIf the Cabinet not open, no need fill in this information2Battery Group Quantity(0,1,2,3)If the Cabinet not open, no need fill in this information3Battery Type(2v,12v)If the Cabinet not open, no need fill in this information4Battery Capacity of Each GroupIf the Cabinet not open, no need fill in this information5Battery InstallationExisting Equipments Information1Qty of Existing BTS Cabinet1Only for TP Equipments2Type of Existing BTS CabinetSiemensOnly for TP Equipments3Dimensions of Existing BTS Cabinet770x770x2100Only for TP Equipments4Qty of Existing Rec. Cabinet1Only for TP Equipments5Dimensions of Existing Rec. Cabinet800x830x2100Only for TP Equipments6Qty of Existing Outdoor Battery Cabinet1Only for TP Equipments7Dimensions of Existing Outdoor Battery Cabinet700x700Only for TP EquipmentsExisting Pad/Shelter Information1Number of shelters/rooms2Dimension of shelter/room13Dimension of shelter/room24Dimension of shelter/room35Dimension of shelter/room4 6Number of air-conditioners7Capacity of Air Conditioner [Tones]No need to fill if there is no label on the air conditioner8Dimension of existing Pad 4500x15009SunshadeAvailableIf not available, please propose new sunshade10Qty of Existing Cabinet on the Existing BTS Pad3choose 0 for indoor site, only for TP BTS pad11Spare Space on the Existing Pad for New Rec or SDR1 CabinetOnly for TP pad12Existing Base Frame TypeNo existing base frame,Short channel (need to be removed),Width less than 660mm,Width more than 660mm.13RemarkAnything else to recordBTS External Alarms1Alarm typeELTEK Rectifier installed(OD)2Existing total alarm points qty 93High Voltage Alarm Status4Door Open Alarm StatusAvailable5AC Main Fail Alarm Status6Low Voltage Alarm Status7Distribution Fuse Alarm Status8Temperature Alarm Status9Generator Running Alarm Status10OB Light Alarm Status11Low Fuel Alarm Status12GEM Active Alarm Status13Spare alarm points(NIL) qty14Rectifier Fail Alarm Status15HEX/LOAD Alarm Status16Spare alarm points(NIL) Status17Hi Temp Alarm Status18Air Conditioner Alarm Status19Smoke Detector Alarm Status20AVR Alarm Status21High Load Alarm Status22GEM Fail Alarm StatusExisting 2G-900Mhz Antenna System InformationItemSector-1Sector-2Sector-3Sector-41Band of AntennaG900G900G9002Antenna TypeKathrein739686Kathrein739686Kathrein7396863BandSingleSingleSingle4Qty of Ports2225Qty of Antennas1116TMA Type Used7Qty of TRX3228Height (AGL) 4343439Azimuth34015027010Mechanical00011Electrical Tilt53312Pole Length3m3m3m13Ant Jumper TypeLCF D-D 1/2"LCF D-D 1/2"LCF D-D 1/2"14Main Feeder TypeLCF 7/8"LCF 7/8"LCF 7/8"15Main Feeder Qty22216Main Feeder Length50505017Combiner Model Used18Combiner Type Used19BTS Jumper TypeSCF D-D 1/2"SCF D-D 1/2"SCF D-D 1/2"Existing 2G-1800Mhz Antenna System InformationItemSector-1Sector-2Sector-3Sector-41Band of Antenna1800A1800A2Antenna TypeKathrein742215Kathrein7422153BandSingleSingle4Qty of Ports225Qty of Antennas116Qty of TRX227TMA Type Used8Height (AGL) 43439Azimuth34015010Mechanical0011Electrical Tilt1112Pole Length3m3m13Ant Jumper TypeLCF D-D 1/2"LCF D-D 1/2"14Main Feeder TypeLCF 7/8"LCF 7/8"15Main Feeder Qty2216Main Feeder Length505017Combiner Model Used18Combiner Type Used19BTS Jumper TypeSCF D-D 1/2"SCF D-D 1/2"SCF D-D 1/2"

&FPage &P

Tower loadingExisting RF Antenna Information(including other operator's ANT)Site ID:QABW01No.Tower Leg No.Antenna Height(m)Antenna AzmuthAntenna Length(mm)Antenna Width(mm)Antenna Thickness(mm)BandVendorAntenna OwnerRemarkLoading(m2)1L1433402580262116G900KathreinTP0.682L1433401314155701800AKathreinTP0.203L2431502580262116G900KathreinTP0.684L2431501314155701800AKathreinTP0.205L3432702580262116G900KathreinTP0.68678910111213141516171819202122232425Current RF Antennas Loading 2.44

Existing MW equipment Information(including other operator's ANT)No.Tower Leg No.Antenna Height(m)Remote SiteAntenna SizeEquipment Type(IDU)Antenna OwnerAntenna AzmuthLoading(m2)1L1311.2TP6012L1221.8TP1033L2331.2TP1551456789101112131415161718Current MW Dishes Loading 4.80

Proposed LoadingNo.ItemsQuantityLoading(m2)12G RRU23G RRU3G RRU30.3m MW dish40.6m MW dish50.9m MW dish61.2m MW dish71.8m MW dish82.0m MW dishTotal Loading 7.2493G AntennaTower Design LoadingProposed Loading 0.00Tower strengthen requiredYES

&FPage &P

Proposed InfoTechnical Site Survey Report Telenor Vega ProjectSite ID: QABW01QtyProposed ItemProposed InformationTipsProposed SWAP Information1RF Configuration for 900MhzS3/2/2/Automatically generated 2RF Configuration for 1800MhzS2/1//Automatically generated 3Swap ModelOD to OD With New PadBS8700W301BS8700BS8800BS8900BS89084SDR TypeBS8700BS8700BS8700 is distributed and RRU installed on the tower/pole, BS8900 is ourdoor macro, BS8800 is indoor marco, BS8908 is metroBS8800Wall Mounted5BBU Installation TypeBS8900BC8910only for distributed, if BBU installed inside of SDR cabinet, no need fill in this informationBS890019''TXN Rack6Qty. of Proposed Macro SDR Cabinet 1BS8908Existing Rec.7Qty. of BS8908BC89108Proposed SDR Cabinet Installed on theIndoorNew PadIf no new SDR cabinet, no need fill in information9Base Frame for New SDR Cabinet (BS8900ABC8910)base frame for existing steel beam(950mm length)For TP Outdoor Site10BBU DC Cable Length(m)2m BBU DC power cableonly for distributed,if BBU installed inside of BS8800,BS8900,BS8908,BC8910 cabinet, please choose N/AN/A11Power Cable length for SDR Cabinet7if BBU installed inside of BS8800, BS8900, BS8908 and BC8910Short ChannelLong Channelbase frame for exisitng channel site(700mm length)12Grounding Cable for BBU Installed Inside of W301(m)if BBU installed in the W301,existing Rec., TRX rack, wall mountedOthersSteel Beam with short channelbase frame for existing steel beam(950mm length)13Grounding Cable for SDR Cabinet(m)5if BBU installed inside of BS8800, BS8900, BS8908 and BC891014Tower Strengthing for 3G Single Band Antenna, RRUs and New MW dishYESOD to ODRRU on the towerBS8700W30115RemarkID to ODMacroBS8800T601Proposed AC Power informationID to IDBS89001Proposed ACDBBS89082Proposed IPS3Required 10 Amp Circuit Breaker 1 Phase AC breakersif no need new breaker, no need fill in this information4Required 16 Amp Circuit Breaker 1 Phase AC breakersif no need new breaker, no need fill in this information5Required 20 Amp Circuit Breaker 1 Phase AC breakersif no need new breaker, no need fill in this information6Required 16 Amp Circuit Breaker 3 Phase AC breakersif no need new breaker, no need fill in this information7Required 32 Amp Circuit Breaker 3 Phase AC breakersif no need new breaker, no need fill in this information8Required 63 Amp Circuit Breaker 3 Phase AC breakersif no need new breaker, no need fill in this information92 Core (16mm2) AC power cable (Between ACDB/IPS/ATS and MCB)if no need new breaker, no need fill in this information104 Core (16mm2) AC power cable (Between ACDB/IPS/ATS and MCB)if no need new breaker, no need fill in this information112 Core (25mm2) AC power cable (Between ACDB/IPS/ATS and MCB)if no need new breaker, no need fill in this information124 Core (25mm2) AC power cable (Between ACDB/IPS/ATS and MCB)if no need new breaker, no need fill in this information13Grounding cable for new pad grounding barUnit:Meter; from new pad grounding bar to existing grounding system.14Grounding cable 16mm2Unit:MeterProposed Rec. Information1Proposed RectifierReuseW301 is outdoor Rec, T601 is indoor Rec, If no need Rec., choose N/A2Proposed New Rec. installed on theif existing Rec. reused, choose N/A3Base Frame for New Rec.only for TP outdoor site42 Core (16mm2) AC power cable (Between ACDB/IPS/ATS and Rec.)Unit:Meter54 Core (16mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Unit:Meter62 Core (25mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Unit:Meter74 Core (25mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Unit:Meter8New DC Power Cable Length(between Rec. and Battery)Unit:Meter9Grounding Cable Length Unit:MeterProposed Battery Information1Proposed New Battery Cabinet TypeN/Aif battery installed outdoor battery cabinet, please choic N/A2Battery Cabinet Installed on theIf no need new battery, no need fill in information3Base Frame for New Battery Cabinetonly for battery cabinet installed on the existing padProposed Outdoor Pad and Sunshade1Swap ModelOD to OD With New Pad2Outdoor Pad for 1 Cabinet With SunshadeRefer to Generic Design3Outdoor Pad for 2 Cabinets With SunshadeRefer to Generic Design4Outdoor Pad for 3 Cabinets With SunshadeRefer to Generic DesignOutdoor fiber(2m)5Outdoor Pad for 4 Cabinets With SunshadeRefer to Generic DesignOutdoor fiber(3m)6Frame and sunshade for additonal BTS or Rectifier (partial; either for BTS or rectifier)Unit:EachOutdoor fiber(5m)7Frame and sunshade for additonal BTS or Rectifier (complete; for one BTS and one rectifier)Unit:EachOutdoor fiber(10m)8BTS and Power cabinets mounting frame with sunshadeUnit:EachOutdoor fiber(20m)9Existing Shelter ModificationUnit:EachOutdoor fiber(25m)10Special Outdoor Pad1Unit:EachOutdoor fiber(30m)11Sunshade Typespecial ODU sunshadeUnit:EachOutdoor fiber(35m)Proposed Cable TrayOutdoor fiber(40m)1300mm Width Horizontal Cable Tray(Indoor)Unit:MeterOutdoor fiber(45m)2300mm Width Vertical Cable Tray(Indoor)Unit:MeterOutdoor fiber(50m)3300mm Width Horizontal Cable Tray(outdoor)3Unit:MeterOutdoor fiber(60m)4300mm Width Vertical Cable Tray(outdoor)Unit:MeterOutdoor fiber(70m)5400mm Width Horizontal Cable Tray(outdoor)Unit:MeterOutdoor fiber(80m)6400mm Width Vertical Cable Tray(outdoor)3Unit:MeterOutdoor fiber(90m)Proposed PipeOutdoor fiber(100m)1Soft PipeFor indoor fiber protection. Unit:MeterOutdoor fiber(115m)2PVC Pipe (Diameter-25mm)For outdoor underground cabling protection. Unit:MeterOutdoor fiber(145m)3PVC DuckFor indoor cabling protection(out of cable bridge part). Unit:MeterOutdoor fiber(160m)4Steel Pipe (Diameter-25mm )For special situation requirments. Unit:MeterOutdoor fiber(175m)5Metal flexible piple10For outdoor on ground cabiling protection. Unit:MeterOutdoor fiber(190m)Proposed 900Mhz Antenna System and RRUs InformationOutdoor fiber(205m)ItemSector-1Sector-2Sector-3Sector-4Outdoor fiber(220m)1Existing Antenna Reused/New AntennaReusedReusedReusedOutdoor fiber(235m)2Antenna BandG900G900G900Outdoor fiber(250m)3Antenna TypeKathrein739686Kathrein739686Kathrein739686Outdoor fiber(280m)4Qty of Antennas111Outdoor fiber(310m)5Port of Antenna222Outdoor fiber(350m)6Height (AGL) 4343437Azimuth3401502708Machanical Tilt0009Electrical Tilt53310Ant. Jumper TypeSCF D-D 1/2"SCF D-D 1/2"SCF D-D 1/2"11Antenna Jumper Length(m)55312BTS Jumper Type13BTS Jumper Length(m)14Qty of TRX (Very Important)32215RRU TypeR8882(MBR)R8882(MBR)R8882(MBR)16Qty. of RRU Type11117RRU Mounting SolutionRRU Mount for Tube Tower for 3 RRUsRRU Mount for Tube Tower for 3 RRUsRRU Mount for Tube Tower for 3 RRUsN/A18Fibre LengthOutdoor fiber(60m)Outdoor fiber(60m)Outdoor fiber(60m)19DC Power Cable Lenth555555Angle TowerRRU Mount for Angle Tower for 3 RRUsProposed 1800Mhz Antenna System and RRUs InsormationMonopoleRRU Mount for Monopole Tower for 3 RRUsItemSector-1Sector-2Sector-3Sector-4Guy MastRRU Mount for Guy Mast Tower for 3 RRUs1Existing Antenna Reused/New AntennaReusedReusedTube TowerRRU Mount for Tube Tower for 3 RRUs2Antenna Band1800A1800ACudee TowerRRU Mount for Cudee Tower for 3 RRUs3Antenna TypeKathrein742215Kathrein742215Rooftop PoleRRU Mount on the Roof Top for 3 RRUs4Qty of Antennas11=IF(C110>0,IF(($D$7"BS8700"),1,IF((C111&C115="R8860E-1800MhzR8860E-1800Mhz")+(C111="R8882(MBR_SHARE WITH 900M)"),1,C112+C116)),0)RRU Mount for Angle Tower for single RRU5Remove Qty of Existing AntennasRRU Mount for Monopole Tower for single RRU6Port of Antenna22RRU Mount for Guy Mast Tower for single RRU7Height (AGL) 4343RRU Mount for Tube Tower for single RRU8Azimuth340150RRU Mount for Cudee Tower for single RRU9Machanical Tilt00Shared With 900Mhz RRU Mount10Electrical Tilt11Wall Mount PoleWall Mount11Ant. Jumper TypeSCF D-D 1/2"SCF D-D 1/2"12Antenna Jumper Length(m)5513BTS Jumper Type14BTS Jumper Length(m)15Qty of TRX (Very Important)21Jumper Temp16RRU Type 1R8882(MBR_SHARE WITH 900M)R8882(MBR_SHARE WITH 900M)DualDualSingleSingle17Qty. of RRU Type 1MBRMBRNN18Fibre Length for Type1111019DC Power Cable Lenth for Type1442020RRU Type 2SCF D-D 1/2"5SCF D-D 1/2"5SCF D-D 1/2"390021Qty. of RRU Type 2SCF D-D 1/2"5SCF D-D 1/2"5180022Fibre Length for Type2442090023DC Power Cable Lenth for Type20000180024RRU Mounting SolutionN/AN/AN/AN/AProposed 3G Antenna System and RRUs InformationItemSector-1Sector-2Sector-3Sector-41Existing Antenna Reused/New AntennaAnt Mount for Angle Tower with 2m Pole 23G BandAnt Mount for Angle Tower with 3m Pole 3Antenna TypeAnt Mount for Monopole with 2m Pole 4Qty of AntennasAnt Mount for Monopole with 3m Pole 5Port of AntennaAnt Mount for GuyMast with 2m Pole 6Ant Mount TypeAnt Mount for GuyMast with 3m Pole 7Height (AGL) Ant Mount for Tube Tower with 2m Pole 8AzimuthAnt Mount for Tube Tower with 3m Pole 9Machanical TiltAnt Mount for Cudee Tower with 2m Pole 10Electrical TiltAnt Mount for Cudee Tower with 2m Pole 11Ant. Jumper TypeDiversity Frame 2.5m Galvanised Iron (GI)12Antenna Jumper Length(m)Diversity Frame 4m Galvanised Iron (GI)13Feeder Type3m rooftop pole14Feeder Length6m rooftop pole15BTS Jumper Type16BTS Jumper Length(m)17RRU Type18Qty. of RRU TypeRRU Mount for Angle Tower for 3 RRUs19RRU Mounting SolutionRRU Mount for Monopole Tower for 3 RRUs20Fibre LengthRRU Mount for Guy Mast Tower for 3 RRUs21DC Power Cable LenthRRU Mount for Tube Tower for 3 RRUsRRU Mount for Cudee Tower for 3 RRUsRRU Mount on the Roof Top for 3 RRUsRRU Mount for Angle Tower for single RRURRU Mount for Monopole Tower for single RRURRU Mount for Guy Mast Tower for single RRURRU Mount for Tube Tower for single RRURRU Mount for Cudee Tower for single RRUWall Mount

&FPage &P

Photos3. Site PhotosSite ID:QABW013.1 Site Basic PhotosPlease refer to Site photo folder

Access RoadSite Overview

Transformer(If have) SharedExisting Battery

Existing ACDB 01(door closed) Existing ACDB 02(door open)

Antenna nameplateGPS record 1

GPS record 2GPS record 3

MCCB Rating Existing MCDB 03(zoom door open)

Existing Rectifier(door closed)Existing Rectifier(door open)

Existing Rectifer Brand& Module TypeExisting Rectifer(zoom door open)

Existing Transmission Rack Exisiting Generator

Existing Transmission Rack(Zoom)Genset Rating

Physical Condition ATS(door closed)ATS(door open)

Existing Vertical Cable LadderExisting Horizontal Cable Ladder

Alarm moduleExisiting Antenna (RF&MW) position on Tower/Pole

Existing BTS RackExisting BTS Rack(door open)

3.2 Site Details View Photo

Tower/Pole StructureExisting Shelter/Room/Outdoor Pad

Existing Sunshade (Outdoor)Existing equipment base frame

Route of Cable LadderExisting Feeder Portholes

Existing Grounding Bar on Tower/poleExisting Outdoor/Indoor Grounding Bar

Lightening ArrestorEarth Pit

Earth Resistance Value (AC)Earth Resistance Value (DC)

Earth Resistance Value (Tower)Existing Sector-1

Existing Sector-2Existing Sector-3

Existing Sector-4Existing Pole 01

Existing Pole 02Existing Pole 03

Existing Pole 04Existing Separate Battery Cabinet

3.3 Proposed New Equipment & Antenna

Proposed New SDR LocationReused Existing DDF

Proposed New Rec. LocationProposed RRU Location-1

Proposed RRU Location-2Proposed RRU Location-3N/A

Proposed RRU Location-4Proposed New Pad Location

New Antenna01 on Tower/pole( Section1)New Antenna02 on Tower/pole( Section2)

New Antenna03 on Tower/pole( Section3)New Antenna 04 on Tower/pole( Section4)

&FPage &P

MaterialItemType of MaterialMaterial CodeUnitLength(m)QtyMaterial DetailAC PowerSite ID:QABW01New outdoor ACDBPowerset01IPSPowerset012 Core (16mm2) AC power cable (Between ACDB/IPS/ATS and MCB)Powerm012 core AC Cable4 Core (16mm2) AC power cable (Between ACDB/IPS/ATS and MCB)Powerm014 core 16mm2 AC Cable2 Core (25mm2) AC power cable (Between ACDB/IPS/ATS and MCB)Powerm012 core AC Cable4 Core (25mm2) AC power cable (Between ACDB/IPS/ATS and MCB)Powerm014 core 25mm2 AC CableRequired 10 Amp Circuit Breaker 1Phase AC breakerspcs01Required 16 Amp Circuit Breaker 1Phase AC breakerspcs01Required 20 Amp Circuit Breaker 1Phase AC breakerspcs01Required 16 Amp Circuit Breaker 3 Phase AC breakerspcs01Required 32 Amp Circuit Breaker 3 Phase AC breakerspcs01Required 63 Amp Circuit Breaker 3 Phase AC breakersPowerpcs01Grounding cable for new pad grounding barPowerm01Copper Thumber Powerpcs10grounding cable 16mm2Powerm01Copper Thumber 0-16 mm2Powerpcs10W301 Installation800mm Base FrameCWset10base frame950mm Base FrameCWset10base frame2 Core (16mm2) AC power cable (Between ACDB/IPS/ATS and Rec.)Powerm012 core AC Cable4 Core (16mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Powerm014 core 16mm2 AC Cable2 Core (25mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Powerm012 core AC Cable4 Core (25mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Powerm014 core 25mm2 AC CableDC (25mm2) power cable (Between Rec. and Battery)Powerm01Battery CableGrounging cable for W301(16mm2)Powerm01Copper Thumber 0-16 mm2Powerpcs10T601 installation2 Core (16mm2) AC power cable (Between ACDB/IPS/ATS and Rec.)Powerm012 core AC Cable4 Core (16mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Powerm014 core 16mm2 AC Cable2 Core (25mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Powerm012 core AC Cable4 Core (25mm2) AC power cable(Between ACDB/IPS/ATS and Rec.)Powerm014 core 25mm2 AC CableDC (25mm2) power cable (Between Rec. and Battery)Powerm01Battery CableGrounging cable for new Rec.(16mm2)Powerm01Copper Thumber 0-16 mm2Powerpcs10Battery 12V Battery cabinetPowercabinet10DC (2 core 1.5mm2) power cable (Between Rec. and Battery for battery cabinet AC)Powerm01DC cable800mm Base FrameCWset10base frame950mm Base FrameCW10base frameGrounding cable for new battery cabinet(16mm2)Powerm50Copper Thumber o-16Powerpcs10BS8800 InstallationDC Blue Power Cable(from rec.25mm2)Powerm01DC cableDC Black GND Cable(from rec.25mm2)Powerm01DC cableGrounding cable(16mm2)Earthingm01Copper Thumber 0-16 mm2Earthingpcs10BS8900 Installation800mm Base FrameCWset10base frame950mm Base FrameCWset10base frameDC Blue Power Cable(from Rec.25mm2)Powerm01DC cableDC Black GND Cable(from Rec.25mm2)Powerm01DC cableGrounding cable(16mm2)Earthingm01Copper Thumber 0-16 mm2Earthingpcs10BS8908 InstallationBS8908 CabinetSDRcabinet10BS8908 Base Frame (Installed on the floor)CWset10BS8908 Wall-mount (Installed to wall)CWset101-TO-1 BS8908 Bracket (A BS8908 installed to pole) SDRset101-TO-2 BS8908 Bracket (Back-to-back installation for 2 BS8908 )SDRset101-TO-3 BS8908 bracket (Combined installation of 3 BS8908)SDRset102 core shielded DC power cable(4mm2, length