up 1144 - fire stop.pdf

5
CRISTANINI 1 Via Porton n. 5    37010 RIVOLI VERONESE (VR)    ITALY Tel. +39-045-6269400 - Fax +39-045-6269411 Url: http://www.cristanini.com e-mail: [email protected] Issue date, 03.06.2008 Review date, 05.10.2012 (ld) FIRE STOP 200/30 (p/n 950090230) FOR INITIAL FIREFIGHTING INTERVENTION FIRE STOP 200/30 is the fastest solution to the need for an initial firefighting intervention in urban areas and places with a difficul access (historical centres, areas with heavy traffic, mountain areas), where the reduced size of equipment is of paramount importance. Thanks to its limited size, FIRE STOP 200/30 is ideal to be used on board of small cars or also on board of ships. UP 1144

Upload: kojkobr

Post on 13-Apr-2018

232 views

Category:

Documents


0 download

TRANSCRIPT

7/26/2019 UP 1144 - FIRE STOP.pdf

http://slidepdf.com/reader/full/up-1144-fire-stoppdf 1/5

CRISTANINI

1

Via Porton n. 5  –  37010 RIVOLI VERONESE (VR)  –  ITALY

Tel. +39-045-6269400 - Fax +39-045-6269411

Url: http://www.cristanini.com 

e-mail: [email protected] 

Issue date, 03.06.2008

Review date, 05.10.2012 (ld)

FIRE STOP 200/30 (p/n 950090230)

FOR INITIAL FIREFIGHTING INTERVENTION

FIRE STOP 200/30 is the fastest solution to the need for an initial firefighting

intervention in urban areas and places with a difficul access (historical centres, areas

with heavy traffic, mountain areas), where the reduced size of equipment is of paramount

importance.

Thanks to its limited size, FIRE STOP 200/30 is ideal to be used on board of small cars or

also on board of ships.

UP 1144

7/26/2019 UP 1144 - FIRE STOP.pdf

http://slidepdf.com/reader/full/up-1144-fire-stoppdf 2/5

CRISTANINI

2

FIRE STOP 200/30 TECHNICAL SPECIFICATIONS

Engine type 2-cylinder petrol

Engine power 14.7 kW (20 HP)

Engine rpm 3250/minute

Start-up Electric (+ emergency start-up by hand)

Start-up battery 12 V 45 Ah

Type of high-pressure pump 3-piston ceramic

High-pressure pump specifications200 bar  – 30 litres/minute(2900 psi  – 7,9 gpm)

Capacity of H2O and foam tanks

120 litre H2O  – 30 litres foam

(31,7 gal –

 7,9 gal)

Operating pressure160-200 bar(2320-2900 psi)

Range of H2O16-17 m. (direct jet)  – 8 m. (diffused jet)(52,4-55,7 - 26,2 ft)

Range of foam/H2O16-17 m. (direct jet)(52,4-55,7 ft)

Capacity of H2O/foam

approx. 30 l/min. water(7,9 gpm)

Max 3 l/min. foam *(0,8 gpm) 

Dimensions and weight without trolley or tanks 900x500x600(H) mm. (35,4x19,6x23,6 in.)kg. 136 (299,8 lb)

Dimensions and weight with trolley and tanks(empty)

1320x700x1200(H) mm. (51.9x27.5x47.2 in)kg. 175 (385,8 lb)

Hose length 20 m. (65,6 ft)

* foam product aspiration up to 10% depending on applications (example: hydrocarbon or

polar solvent fires) and extinguishing products used.N.B.: Foam product aspiration ratio:

-  up to 3% for hydrocarbons-  up to 6% for polar solvents

FIRE STOP 200/30 stands out for its versatility, which means it can be used withextinguishing products (medium expansion foam) with variable percentages of mixing withwater. It is equipped with 2 suction devices of extinguishing products (foam):

  1 device located in the water aspirator at the high-pressure water pump inlet

  1 device located in the high pressure line, after the pump..

FIRE STOP 200/30 uses a new technique, based on the consumption of a small amount ofatomised water, the consequence of the high pressure guaranteed by the piston pump.

The atomised water rapidly turns into vapour and absorbs the heat produced by the fire.This system eliminates damage caused by the large amounts of water normally used withlow-pressure jets.

7/26/2019 UP 1144 - FIRE STOP.pdf

http://slidepdf.com/reader/full/up-1144-fire-stoppdf 3/5

CRISTANINI

3

FIRE STOP 200/30 is complete of:

POS. COMPONENTS DESCRIPTION

1 Chassis

In painted steel RAL 3000. Dimensions:

1020x550x610 mm. (40.1x21.6x24 in.),

including the support for the firefighting

lance and hose reel. The chassis is equipped

with n. 4 handles for movement and lifting.

2 Pressure regulation valve

Allows the adjustment of the pressure

between 30 and 200 bar (435-2900 psi) and

water recirculation when the group isrunning and the lance is closed.

1

10

12

2

3

4

5

6

78

9

11

13

14

15

1010.2

10.1

7/26/2019 UP 1144 - FIRE STOP.pdf

http://slidepdf.com/reader/full/up-1144-fire-stoppdf 4/5

CRISTANINI

4

3 Thermostatic valve

Protects the pump from eventual

overheating resulting from water heating

recirculating in the pump caused by a

prolonged functioning of the group with the

lance closed.

4 Supply water filter

In general, allows to filter incoming water in

the high pressure pump. It is made with a

brass body and a stainless steel filtering

element.

5 Pressure gaugeGauge for high pressure water in glycerine

bath, with scale 0-250 bar (0-3625 psi)

6Intake systems of self-extinguishing

products

The two devices allow the use of a widerange of flame retardant products (foam)

with different percentages of mixing with

water. Each device has its own suction line

with filter and bottom valve. 

7 Battery

The electic start-up engine is allowed by the

battery (placed and fixed within the

chassis). Features: 12V/45Ah.

8 Manual hose reelManual, equipped with a 20 m (65.6 ft) highpressure hose able to enrol up to 50 m. (164

ft) of hose.

9 High pressure hose The hose length is 20 m. (65.6 ft).

10 High pressure firefighting lance

Equipped with a gun, allows the delivery of

water or water mixed with flame resistant

foam products.

The water or foam range can reach approx20 m. (65.6 ft).

10.1 Firefighting nozzle

To have a jet of water or water mixed with

foam products. This nozzle can work in

different mode: long distance jet or

expanded short jet.

10.2 Nebulizer

The nebulizer (only water) decreases the

temperature of the flames, thus favoring

extinguish fire.

7/26/2019 UP 1144 - FIRE STOP.pdf

http://slidepdf.com/reader/full/up-1144-fire-stoppdf 5/5

CRISTANINI

5

11 Fuel tank

Made of stainless steel, it has a capacity of

about 6 l. (1.58 gal.), allowing a range of

continuous operation of the group of at

least 1,30 hours.

12 Water tank

With a capacity of 120 l. (31.7 gal.). The tank

is placed above the group and is provided

with its own support and fixation, but it can

be quickly separated.

The tank height is 450 mm. (17.7 in.)

The tank, once emptied, can be quickly

disassembled.

The tank is equiped with:

a) visual inspection of the level

b) Ø 35 connection for water charging

c) connecting pipe and power

d) opening for cleaning

e) outlet plug.

13 Support of product tankIt allows to place a tank or a container of

fire extinguishing products.

14 Trolley with wheelsWith 2 wheels of large diameter (300 mm.),

quickly separable.

15 Tank of chemical products Estinguishing or flame retardant

TECHNICAL SPECIFICATIONS CAN VARY WITHOUT NOTICE.