wlc2 - '+domain name+'...suitable motor h.p. any motor / pump either single phase or three...

2
SAVE WATER, FULLY AUTOMISE & SOLVE OVERFLOW PROBLEMS WLC1 WLC2 WATER LEVEL CONTROLLERS WATER LEVEL CONTROLLERS WATER LEVEL CONTROLLERS Fully Automatic Pump operation for Single Tank / Bore well Sensing of Levels by Stainless Steel Prods. (Magnetic Sensors for Non Conductive Liquids.) User selectable “ SUCTION” or “DELIVERY” logic. Auto/ Manual option in case of emergency. Economically priced. SensitivityAdjustment for Hard & Soft Water. DIN Rail / Wall mounting sturdy Plastic enclosure. Can be used for Single Phase or Three Phase Pump of any capacity. Fully Automatic Pump operation for Two Tanks. Sensing of levels by Stainless Steel Prods. Auto/Manual option in case of emergency. Low Level and Safe Limit indications on the Front Panel. SensitivityAdjustment for Hard & Soft Water. DIN Rail / Wall mounting sturdy Plastic enclosure. Can be used for Single Phase or Three Phase Pump of any capacity. (Magnetic Sensors for Non Conductive Liquids.)

Upload: others

Post on 20-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WLC2 - '+domain name+'...Suitable motor H.P. Any Motor / Pump either Single Phase or Three Phase Dimensions ( in mm ) Main Unit : 60(W) x 70(H) x 110(D), Sensor : 16 x 50 mm Mounting

SAVE WATER, FULLY AUTOMISE & SOLVE OVERFLOW PROBLEMS

WLC1

WLC2

WATER LEVEL CONTROLLERSWATER LEVEL CONTROLLERSWATER LEVEL CONTROLLERS

Fully Automatic Pump operation forSingle Tank / Bore well

Sensing of Levels by Stainless Steel Prods.

(Magnetic Sensors for Non Conductive Liquids.)

User selectable “ SUCTION” or “DELIVERY” logic.

Auto/ Manual option in case of emergency.

Economically priced.

SensitivityAdjustment for Hard & Soft Water.

DIN Rail / Wall mounting sturdy Plastic enclosure.

Can be used for Single Phase orThree Phase Pump of any capacity.

Fully Automatic Pump operation for Two Tanks.

Sensing of levels by Stainless Steel Prods.

Auto/Manual option in case of emergency.

Low Level and Safe Limit indications on the FrontPanel.

SensitivityAdjustment for Hard & Soft Water.

DIN Rail / Wall mounting sturdy Plastic enclosure.

Can be used for Single Phase or

Three Phase Pump of any capacity.

(Magnetic Sensors for Non Conductive Liquids.)

Page 2: WLC2 - '+domain name+'...Suitable motor H.P. Any Motor / Pump either Single Phase or Three Phase Dimensions ( in mm ) Main Unit : 60(W) x 70(H) x 110(D), Sensor : 16 x 50 mm Mounting

We also manufacture WLC2A Two Tank Water Level Controller with Dry Run & Single Phasing Protection. It also has

an optional Remote Display Unit.

Product improvement is a continuous process, Data given in this publication is, therefore, subject to revision.

WLC1 SINGLE TANK WATER LEVEL CONTROLLER

ABOUT WLC1

PRINCIPLE OF WLC1 OPERATION

WHO CAN USE WLC1?

WLC1 is a water level controller used for automatic pumping

operation for a Single Tank.

WLC1 operates on the principle of electrical conductivity. Sensing

prods are suspended in water. Water act as a conductive medium for

current path between the prods. WLC1 maintains the water level

between the upper and lower level in the same tank. There are three

prods (Sensors). One for Higher level, one for lower level and one for

reference.

With the help of Shortlinks WLC1 can be operated in either ‘Delivery

Logic’ or ‘Suction Logic’. In Delivery Logic all prods are suspended in

over head tank. In Suction Logic all prods are suspended in Under

Ground Suction Tank.

WLC1 is ideally suited for Borewell pumping operation, level

maintenance in one Single tank from an Infinite Water Source,

Industries, Level Alarms etc... WLC1 can also be used Non conductive

liquids like Diesel, Lubricating oils, etc. with the help of Magnetic

Sensors.

WLC2 TWO TANK WATER LEVEL CONTROLLER

ABOUT WLC2

PRINCIPLE OF WLC2 OPERATION

WHO CAN USE WLC2?

WLC2 is a water level controller used for automatic pumping

operation between Two tank (Under Ground & Over Head). It is used to

maintain the water level in the over Head Tank, always.

WLC2 also operates on electrical conductivity principle same as that

explained in WLC1.

WLC2 has Six prods, three prods for each tank. One reference, one

higher level and one lower level.

WLC2 will start the pump if the water level in the Over Head Tank goes

below its low level, provided the water in the Under Ground Tank is

above its low level, WLC2 shall stop the pump if the water level in the

Over Head Tank reaches its high level or if the water in the Under

Ground Tank goes below its low level.

WLC2 is ideally suited for Automatic pumping operation between the

Two Tanks in places like Industries, Housing Societies, Apartments,

Banglows, Hotels, Lodges, Hospitals etc... WLC2 can also be used for

any Industrial application involving liquids other than water like Dairy

(milk), Pharma (Syrup), Food (juices), Chemicals etc. WLC2 can also

used for Non Conductivity liquids like Diesel, Lubricating oils etc. with

the help of Magnetic Sensors.

CONNECTION DIAGRAM OF WLC1

WLC1 USED IN SUCTION LOGIC

7 8 9

OFF OFFON ON

987PUMP

1 2 3 4 5 6

12 11 10 9 8 7

L N E NO NCC

2 6 4

1 5

P3 P1P2

987

WLC1 USED IN DELIVERY LOGIC

H212

L211

C210

H19

L18

C17

1 2 3 4 5 6

L N E N/C C NOPump

2 6 4

1 5

CONNECTION DIAGRAM OF WLC2

L1C1 H1

OVER HEAD TANKOVER HEAD TANK

PUMP

UNDER GROUND TANKUNDER GROUND TANK

L2C2 H2

Auxiliary Supply Voltage 230VAC 50Hz Single Phase

Power Consumption 3VA 3VA

Input Sensors SS 304/316 with Nylon plastic covering

Sensing Voltage 12VDC 30VDC

Sensing Cable length No limit

Output Relay 1 c/o 6A @ 230 VAC resistive

Trip Time delay less than one second

Resetting Automatic

Sensitivity adj. 0 to 200K 0 to 140K

Indications Power ON, Relay ON Power , Relay , Low level, Safe limit

Suitable motor H.P. Any Motor / Pump either Single Phase or Three Phase

Dimensions ( in mm ) Main Unit : 60(W) x 70(H) x 110(D), Sensor : 16 x 50 mm

Mounting 35 mm Rail or Wall mounting

Enclosure Virgin Plastic ABS

Weight Main Unit : 665 gms (approx), Sensors : 55 gms (approx)

ø

TECHNICAL SPECIFICATIONS WLC1 WLC2

Manufactured by :

Cogent Controls205, Vinay Industrial. Estate., Chincholi Bunder Link Road,Malad-W, Mumbai - 400 064 Tel: 28750421/20Email: [email protected] /[email protected] : www.cogentcontrols.com