Page 1: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

cara I-Bar®

Instructions for Digital Workflow

Giving a hand to oral health.

Step by Step Guide

Page 2: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

2

Instructions for designing cara I-Bar orders

We at Kulzer are traditional partners for dental laboratories and dental practices and we are one of the world’s leading dental companies. We have approximately 80 years of experience in the dental market, which helps us make the work of dental technicians and dentists easier, more efficient and more precise.

We are also continuously refining our technologies and processes. As a result we can offer users the best materials so that every day they can give patients back their smiles and their quality of life.

This guide for scanning and designing the cara I-Bar using 3Shape is a step-by-step guide for achieving a successful digital design for an implant bar. This technology has the advantage of saving you valuable time. You always specify the design yourself. Every patient case is individually produced for you in line with your wishes and requirements.

Page 3: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

3

Contents:

General information ............................................................................................................... 4

Ordering procedure ................................................................................................................ 5

Scanning ............................................................................................................................... 7

Designing ............................................................................................................................. 11

Ti

CoCr milled

Page 4: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

4

General information how to place an order at a glance

Scan the model together with the tooth setup, the scan bodies and the gingival mask using the 3Shape process. To get started with this you will need a scanner, the software license for Implant Bars and Bridges or CAD Points and scan bodies in addition to an implant library for cara I-B&B from Kulzer. A scan body is required for each implant (implant system, platform and size).

If you are using the 3Shape software with the Implant Bars and Bridges design module for cara I-Bridge and cara I-Bar, you can design the bar digitally and therefore faster since there is no need to create a prototype (wax-up). You design the cara I-Bar and decide whether you want to use angled or regular.

A plaster model is required to ensure a perfect fit for the bars.

If you order the cara I-Bar directly via 3Shape and submit the data via the cara Inbox before 13:00, this counts as day 1 of the order placement. Please note that if the model arrives in Hanau, Germany on the second day, calculation of the production process can be shortened by one day overall.

If you would like Kulzer to organize the pick-up service for your cara I-Bar model, please make a note of this in the comments field of the Dental Manager software.

The Kulzer system range now also includes scan bodies for all standard implant systems. The new two-part rotatable cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater safety during handling and precise scan results. Of course, all cara I-Products with the scan bodies and libraries can still be obtained from NT Trading (NT 3D Guide) and Medentika (1st and 2nd generation). For cara I-Bar on Thommen and Dentaurum implants, you will need the scan bodies and original analogues from the manufacturer. You’ll find both systems in the category “other systems B&B”.

You can see all the available implant systems for digitally designing the cara I-Bar in the cara I-Bar platform overview.

Our Technical Advisory Service will be happy to answer any queries you may have regarding design: [email protected]

Page 5: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

5

Ordering procedureStep-by-step explanation.

STEP 1

Select the settings for your specific requirements in Scan settings.

Highlight the teeth where the implant will be placed. You can highlight several teeth at the same time if the system, size and material are identical. Otherwise each implant must be highlighted individually.

Select Customized abutment and the cara I-B&B category (this depends on which scan body you are using). cara I-B&B SCAB (Kulzer Scanbodys), cara I-B&B NT3D, cara I-B&B conical (Medentika and nt-trading 1st generation), cara I-B&B cylindrical (Medentika 2nd generation), the desired implant system and the appropriate diameter.

Page 6: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

6

STEP 2

Press + to select the material (e. g. cara I-B&B titanium). Select Kulzer Milling Centre in the manufacturer’s menu and cara I-B&B under Production process. If you would also like to scan in a tooth setup in wax, please select the option “Double preparation/Wax-up”.

STEP 3

Highlight all the elements of the design and select first Bridge and then Bar. If you would like the model to be picked up, please write “Please have model picked up” in the comments field.

Ordering procedure

Page 7: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

7

Scanning

STEP 4

Please use a separate scan body for each implant. If you only work with one scan body for several implants, there is a chance of errors arising during the scanning process which may impair the fit of the implant bar. Do not, therefore, choose the option “Use only one scan abutment”. Screw the scan bodies into the model and place the model in the scanner.

STEP 5

Follow the instructions on the screen.

Page 8: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

8

Scanning

STEP 6

STEP 7

Page 9: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

9

Scanning

STEP 8

STEP 9

Page 10: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

10

STEP 10

Follow the instructions in the left-hand column and highlight the abutments as illustrated.

Scanning

Page 11: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

11

STEP 11

Set the insertion direction of the implant bar.

STEP 12

Design the implant bar to your requirements.You can change the dimensions of the bar by dragging the blue and green points under the item, Edit bar. Where possible, try to completely integrate the abutments in the bar design to obtain a uniform bar shape. Ensure that the bar penetrates the jaw as little as possible from the basal direction before adjusting the bar to the gingiva.

Designing

Page 12: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

12

Designing

STEP 13

You have the option to add attachments under the item Modify.In the menu “Group”, you will find the Kulzer entry and can then select the cara Preci v+h 1.8 no Base & cara Preci v+h 1.8 (v=vertix & h=horix) attachments. Click on 1.),,Apply all placed attachments’’ and 2.),,Cut bar to gingiva’’.

STEP 14

If you click on the implant on the dental chart, select Parametric and check next to Insertion direction, the abutments will be placed in the same insertion direction as the bar.

2

1

Page 13: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

13

Designing

STEP 15

If you need an angled screw channel, check “Angled screw hole” in the menu under “Assembly” and set the desired number of degrees (max. 20°). Then go back to Modify framework design. Please ensure that the vestibular or buccal wall thickness is adequately dimensioned in the case of angled screw channels, otherwise the required wall thickness of the angled screw channel will be adjusted automatically in production.

Important:

The minimum wall thickness of an angled screw channel in the designated area is 1.5 mm.

Page 14: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

14

STEP 16

Add material bit by bit at the point where the screw channel exits. You can show the screw channels to help you do this. This step is necessary as the screw channel is not visible in the STL file in production.

Designing

Page 15: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

15

STEP 17

Please bear in mind that it may be necessary to machine-finish the surfaces in the case of parallel-walled bars.

When everything is ready, click Next or Close and send the file to Kulzer.

Designing

cara I-Bar ® primary structure for fixed and removable dentures.

Page 16: cara I-Bar Instructions for Digital Workflow · cara scan bodies with a PEEK abutment and stainless steel connection geometry for intraoral and extraoral application provide greater

© 2018 Kulzer GmbH. All Rights Reserved.

W19

370

EN 0

4/2

018

OR

T

Contact in GermanyKulzer GmbH Leipziger Straße 2 63450 Hanau, Germany [email protected]

Signum Bonding agents – strong and secure bonding.

Regardless of the indication, the Signum range of bonding agents: metal bond, zirconia bond and ceramic bond, will have a product to suit your requirements. Signum bonding agents provide perfect conditioning for every material. Each of the three Signum bonders is a specialist in its field of either dental alloys, zirconia or silicate ceramics.

Features:■■ Intraoral and extraoral application.■■ High bonding strength.■■ Extremely thin layer.■■ Easy, safe and efficient application.

Find out more about Signum www.kulzer.com/Signum

kulzer.com/cara