Corporate Headquarters:100 Thermon Dr • PO Box 609 San Marcos, TX 78667-0609 • Phone: 512-396-5801 • 1-800-820-4328 For the Thermon office nearest you visit us at . . . www.thermon.com © Thermon, Inc. • Printed in U.S.A. • Informaon subject to change. Form TEP0168-0717 Ordinary Locaons Hazardous Locaons IEC/EN/UL/CSA 60950-1 E114023 Cl I, Div 2, Gp ABCD T4; Cl I, Zone 2, AEx nA IIC T4 Gc; Ex nA IIC T4 Gc; II 3 G Ex nA IIC T4 Gc; IECEx EMT17.0009X Ex nA IIC T4 Gc; -40°C ≤ Ta ≤ 70°C APPLICATION The TraceNet™ Data Communication Device (DCD) is specifically designed to efficiently facilitate the rapid communicaon from heat tracing controllers across a wide spectrum of computer networks. Through adapve and agile programming, the DCD is able to coordinate the informaon flow from up to a hundred controllers per serial port and disperse it to any number of operator and Distributed Control System (DCS) workstaons. The DCD functions by acting as a dedicated headless industrial data communicaon device that communicates via MODBUS communication protocol to a variety of Thermon temperature control and monitoring devices. The DCD collects data from the modules from either its built- in RS-485 serial ports or its Ethernet port and distributes that informaon to specified operator workstaons and data centers. It can be configured to communicate through various MODBUS protocols, including MODBUS TCP and MODBUS RTU over RS-485. TraceNet DCD is fully buffered, containing a complete set of memory maps of all Thermon Controllers in its RAM for fast, simultaneous communicaon to mulple MODBUS TCP clients. Through use of its read-only hard-drive for its operang system and its read/write FLASH RAM for configuraon sengs, the TraceNet DCD can be quickly configured to support any network design and rapidly improve exisng communicaon systems. The TraceNet DCD features a rugged design and a small footprint, ideal for use indoor and in outdoor enclosures of NEMA 4, 4X, and 12. RATINGS TraceNet DCD is a family of microprocessor based data communicaon devices with the following specificaons: Nominal Supply Voltage .......................................... 24 VDC Input /Output Ports DCD-3 ...... 10/100/1000, Ethernet, 4 USB 2.0, 3 x RS-485, 1 x CAN DCD-1 ... 10/100/1000, Ethernet, 2 USB 2.0, 4 x RS-485 (COM 1-4) Maximum Storage Temperature ............ 185°F (85°C) Minimum Storage Temperature .................... -40°F (-40°C) Operang Ambient Temperature Range DCD-3.................................. -40°F (-40°C) to 158°F (70°C) DCD-1....................................-4°F (-20°C) to 158°F (70°C) ModBus Serial Communicaons Up to 247 ModBus devices can be connected to the RS-485 serial ports up to a distance of 4000 feet (1220 m). PRODUCT SPECIFICATIONS TraceNet DCD DATA COMMUNICATION DEVICE PRODUCT FEATURES • Modules are available to operate TCP or UDP over Ethernet in ambient conditions ranging from -40°F (-40°C) to 158°F (70°C). • Serves MODBUS data simultaneously to mulple TCP clients such as DCS/SCADA or TraceNet Command. • Robust with field proven performance reliability. • Power cycle tested with auto restart on error. • Remotely configurable from anywhere on the network. • DIN rail mountable. CERTIFICATIONS The DCD-3 is for use in indoor and outdoor applicaons and has the following hazardous locaon cerficaons: The DCD-1 is for use in indoor applicaons and ordinary classified locaons.

Upload: others

Post on 27-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: DATA COMMUNICATION DEVICEvia MODBUS communication protocol to a variety of Thermon temperature control and monitoring devices. The DCD collects data from the modules from either its

Corporate Headquarters:100 Thermon Dr • PO Box 609 San Marcos, TX 78667-0609 • Phone: 512-396-5801 • 1-800-820-4328 For the Thermon office nearest you visit us at . . . www.thermon.com

© Thermon, Inc. • Printed in U.S.A. • Information subject to change.Form TEP0168-0717

Ordinary LocationsHazardous Locations

IEC/EN/UL/CSA 60950-1 E114023

Cl I, Div 2, Gp ABCD T4;Cl I, Zone 2, AEx nA IIC T4 Gc;Ex nA IIC T4 Gc; II 3 G Ex nA IIC T4 Gc;IECEx EMT17.0009X Ex nA IIC T4 Gc; -40°C ≤ Ta ≤ 70°C

APPLICATIONThe TraceNet™ Data Communication Device (DCD) is specifically designed to efficiently facilitate the rapid communication from heat tracing controllers across a wide spectrum of computer networks. Through adaptive and agile programming, the DCD is able to coordinate the information flow from up to a hundred controllers per serial port and disperse it to any number of operator and Distributed Control System (DCS) workstations.The DCD functions by acting as a dedicated headless industrial data communication device that communicates via MODBUS communication protocol to a variety of Thermon temperature control and monitoring devices. The DCD collects data from the modules from either its built-in RS-485 serial ports or its Ethernet port and distributes that information to specified operator workstations and data centers. It can be configured to communicate through various MODBUS protocols, including MODBUS TCP and MODBUS RTU over RS-485. TraceNet DCD is fully buffered, containing a complete set of memory maps of all Thermon Controllers in its RAM for fast, simultaneous communication to multiple MODBUS TCP clients. Through use of its read-only hard-drive for its operating system and its read/write FLASH RAM for configuration settings, the TraceNet DCD can be quickly configured to support any network design and rapidly improve existing communication systems. The TraceNet DCD features a rugged design and a small footprint, ideal for use indoor and in outdoor enclosures of NEMA 4, 4X, and 12.

RATINGSTraceNet DCD is a family of microprocessor based data communication devices with the following specifications:

Nominal Supply Voltage .......................................... 24 VDCInput /Output Ports DCD-3 ...... 10/100/1000, Ethernet, 4 USB 2.0, 3 x RS-485, 1 x CAN DCD-1 ... 10/100/1000, Ethernet, 2 USB 2.0, 4 x RS-485 (COM 1-4) Maximum Storage Temperature ............ 185°F (85°C)Minimum Storage Temperature .................... -40°F (-40°C)Operating Ambient Temperature Range DCD-3 ..................................-40°F (-40°C) to 158°F (70°C) DCD-1 ....................................-4°F (-20°C) to 158°F (70°C)

ModBus Serial CommunicationsUp to 247 ModBus devices can be connected to the RS-485 serial ports up to a distance of 4000 feet (1220 m).

PRODUCT SPECIFICATIONS

TraceNet DCD™

DATA COMMUNICATION DEVICE

PRODUCT FEATURES• Modules are available to operate TCP or UDP over

Ethernet in ambient conditions ranging from -40°F (-40°C) to 158°F (70°C).

• Serves MODBUS data simultaneously to multiple TCP clients such as DCS/SCADA or TraceNet Command.

• Robust with field proven performance reliability.• Power cycle tested with auto restart on error.• Remotely configurable from anywhere on the network.• DIN rail mountable.

CERTIFICATIONSThe DCD-3 is for use in indoor and outdoor applications and has the following hazardous location certifications:

The DCD-1 is for use in indoor applications and ordinary classified locations.

Page 2: DATA COMMUNICATION DEVICEvia MODBUS communication protocol to a variety of Thermon temperature control and monitoring devices. The DCD collects data from the modules from either its

DIMENSIONS

PRODUCT SPECIFICATIONS

TraceNet DCD™

DATA COMMUNICATION DEVICE

CAN Communications

RS-485 Communications

Ethernet Communications

DCD-3 DataCommunication Device

TraceNetTN (TSM1)

BPM-12

TraceNetCommand

Apps

TraceNetCommandDatabase

DCS

TYPICAL TN SERIES COMMUNICATION NETWORK

TYPICAL TCM-18 SERIES COMMUNICATION NETWORK

DCD-3 DataCommunication Device

TCM-18’s

TraceNetCommand

Apps

TraceNetCommandDatabase

DCS

8.27” (210 mm)

2.76” (70 mm)

5.8” (147 mm)

DCD-3

DCD-1

6.1” (155 mm)

1.89” (48 mm)

4.33” (110 mm)