finishes manufacturer's product guide
Embed Size (px)
DESCRIPTION
Here is a description of Conwed Designscape's innovative sound improvement products and solutions.TRANSCRIPT
-
9FINISHES MANUFACTURERS PRODUCT GUIDE FINISHES MANUFACTURERS PRODUCT GUIDE DIVISION
** SECTION INFO **** BOOK CODE **di914flx** SECTIONGROUPTYPE **011** COLUMN COUNT **3
-
TABLE OF CONTENTS
GUIDE SPECIFICATIONSConwed Designscape | Wall Technology Sound Absorptive Wall Panels
- Foundations Acoustical Wall Panels - Rebound Panels - Resist Acoustical Panels - Respond A Series (A100/A200/A300/A400) Acoustical Panels - Respond IR Series (IR108/IR308/IR408) Acoustical Panels - Respond TK/AC Acoustical Panels
Sound Absorptive Ceilings - Access Ceiling System - Foundations Acoustical Ceiling Panels - Gridlock Acoustical Ceiling Panels - New Dimensions Acoustical Ceiling Panels
Sound Absorptive Clouds - Respond Curved Reflective Ceiling Clouds - Respond Reflector Ceiling Clouds, Flat - Skyway Ceiling Clouds Type 1 - Skyway Ceiling Clouds Type II
Sound Absorptive Specialty Products - Loaded Vinyl Acoustical Panels - Low Frequency Tuner - Metro Rebound Panels - Reflective Wall Panels - Urban Forest - Wedge Wall Panels
Sound Absorptive Diffusers - Omni Plane Diffuser Panel - Respond Diffusers: Barrel and Pyramidal
Sound Absorptive Baffles - Respond Baffles: Fold-Up and Back-to-Back
SelectSound
SelectSound Black Acoustic Board SelectSound Black Acoustic Blanket
Eurospan Stretch System Eurospan Ceiling System
- Eurospan Classic Ceiling System - Eurospan EOS Ceiling System - Eurospan Translucence Ceiling System
Eurospan Wall System - Eurospan Acoustical Wall System
Acoustic Insulation QuietZone Acoustic Batts with PureFiber Technology
RESOURCESConwed Designscape | Wall Technology Sound Absorptive Wall Panels Product Data Sheets
- Foundations Acoustical Wall Panels - Rebound Panels - Resist Acoustical Panels - Respond A Series (A100/A200/A300/A400) Acoustical Panels - Respond IR Series (IR108/IR308/IR408) Acoustical Panels - Respond TK/AC Acoustical Panels
Sound Absorptive Ceilings Product Data Sheets - Access Ceiling System - Foundations Acoustical Ceiling Panels - Gridlock Acoustical Ceiling Panels - New Dimensions Acoustical Ceiling Panels
Sound Absorptive Clouds Product Data Sheets - Respond Curved Reflective Ceiling Clouds - Respond Reflector Ceiling Clouds, Flat - Skyway Ceiling Clouds Type 1 - Skyway Ceiling Clouds Type II
Sound Absorptive Specialty Product Data Sheets - Loaded Vinyl Acoustical Panels - Low Frequency Tuner - Metro Rebound Panels - Reflective Wall Panels - Urban Forest - Wedge Wall Panels
Sound Absorptive Diffusers Product Data Sheets - Omni Plane Diffuser Panel - Respond Diffusers: Barrel and Pyramidal
Sound Absorptive Baffles Product Data Sheets - Respond Baffles: Fold-Up and Back-to-Back
-
TABLE OF CONTENTS
RESOURCESConwed Designscape | Wall Technology Installation Guidelines
- Access Ceiling System - Gridlock Acoustical Ceiling Panels - Impaling Clip/Adhesive - Impaling Clip with Resin Spots - Respond Baffles - Respond Diffusers - Splines: Wall and Ceiling - Wall Panels Adhesive, No Resin - Z-Bar with Hook and Loop - Z-Bar to Z-Bar - Z-Clip to Z-Bar - Z-Clip to Double Wall Brackets
Limited Warranty - Wall and Ceiling Panels Warranty
Cleaning and Maintenance - General Cleaning and Maintenance Guide
SelectSound
SelectSound Black Acoustic Board Product Data Sheet SelectSound Black Acoustic Blanket Product Data Sheet
Eurospan Stretch System Eurospan Ceiling System
- Eurospan Classic Ceiling System Product Data Sheet - Eurospan Classic Ceiling System Typical Details - Eurospan Classic Fabric Maintenance and Cleaning Guide - Eurospan EOS Ceiling System Product Data Sheet - Eurospan EOS Fabric Maintenance and Cleaning Guide
Eurospan Wall System - Eurospan Wall System Product Data Sheet - Eurospan Wall System Typical Details - Eurospan Wall Fabric Maintenance and Cleaning Guide
Plaster & Gypsum Board Accessories
- Quietzone Noise Control Batts Product Data Sheet - QuietZone Acoustic Sealant Product Data Sheet - QuietZone Acoustic Wall Framing Product Data Sheet
Acoustic Underlayment - QuietZone Acoustic Floor Mat Product Data Sheet
Acoustic Insulation - EcoTouch Sound Attenuation Batts (SAB) with
PureFiber Technology Product Data Sheet - EcoTouch Fiberglas Insulation with PureFiber
Technology Product Data Sheet
TECHNICAL SERVICESFor technical questions, please call 1-800-GET-PINK or 1-800-438-7465. Our Technical Service Department is available to assist Monday through Friday from 8 a.m. 5 p.m. EST.
HOW TO ORDER LITERATUREIf you need to order literature, please refer to the publication number associated with a particular publication. If applicable, these publication numbers can be found at the bottom of the document near the copyright information. To place an order, call Owens Corning Customer Response Center at 1-800-GET-PINK or 1-800-438-7465.
-
Foundations Acoustical Wall Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Foundations Acoustical Wall Panels
-
Foundations Acoustical Wall Panels
1. Construction: Composite core of dimensionally stable rigid fiberglass laminated with 16 - 20 pcf molded glass fiber and covered with a specially formulated fiberglass mat.
2. Core Fiberglass Density: 6 - 7 pcf. 3. Cores laminated with 1/8 inch thick, 16 - 20 pcf molded glass fiber. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 7/8 inches. 6. Core Thickness: 1-1/8 inches. 7. Core Thickness: 1-5/8 inches. 8. Core Thickness: 2-1/8 inches. 9. Core Thickness: 3-1/8 inches. 10. Core Thickness: 4-1/8 inches. 11. Width: 24-48 inches and custom. 12. Length: 24-120 inches and custom. 13. Corners: Square. 14. Edge Profile: Square. 15. Edge Profile: Bevel (1/2 inch minimum). 16. Edge Treatment: Resin hardened. 17. Finishes: Acoustically transparent fiberglass mat, applied directly over face and edges of acoustical panels to
provide full finished edge. 18. Corners: Fully tailored. 19. Finish Type and Color: Soft Texture finish, white (can be field-painted). 20. Mounting Type: Adhesive / Resin. 21. Mounting Type: Impaling / Adhesive / Resin. 22. Mounting Type: Lay-in. 23. Mounting Type: Magnet. 24. Mounting Type: Spline. 25. Mounting Type: Velcro. 26. Mounting Type: Panel Clip to Z-Bar. 27. Mounting Type: Panel Clip to Double Wall Clip. 28. Mounting Type: Z-Bar to Z-Bar. 29. Mounting Type: Aluminum Z-Clip. 30. Mounting Type: Panel-Clip / Velcro. 31. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 32. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 33. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1-1/8 inch Thickness: 0.90. b. Noise Reduction Coefficient (NRC) for 2-1/8 inch Thickness: 1.10.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries..
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Rebound Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Rebound Panels
1. Construction: Composite core of dimensionally stable rigid fiberglass.
-
Rebound Panels
2. Core Fiberglass Density: 6 - 7 pcf. 3. Cores laminated with 1/16 inch thick, resilient perforated co-polymer face sheet. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 1-1/16 inches. 6. Core Thickness: 1-9/16 inches. 7. Core Thickness: 2-1/16 inches. 8. Width: 24-48 inches and custom widths up to 53 inches. 9. Length: 24-120 inches and custom. 10. Corners: Square. 11. Corners: Radiused. 12. Edge Profile: Square. 13. Edge Profile: Miter for corner conditions. 14. Edge Treatment: Resin hardened. 15. Edge Treatment: Aluminum for square edge only. 16. Edge Treatment: High-pressure laminate, for square edge only. 17. Corners: Fully tailored. 18. Finish: Manufacturer, type and color as selected. 19. Mounting Type: Adhesive / Resin. 20. Mounting Type: Adhesive No Resin. 21. Mounting Type: Impaling / Adhesive. 22. Mounting Type: Lay-in. 23. Mounting Type: Magnet. 24. Mounting Type: Spline. 25. Mounting Type: Velcro. 26. Mounting Type: Panel Clip to Z-Bar. 27. Mounting Type: Panel Clip to Double Wall Clip. 28. Mounting Type: Z-Bar to Z-Bar. 29. Mounting Type: Aluminum Z-Clip. 30. Mounting Type: Panel-Clip / Velcro. 31. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 32. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 33. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1-1/16 inch Thickness: 0.85.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Resist Acoustical Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Resist Acoustical Panels.
1. Construction: Composite core of dimensionally stable rigid fiberglass.
-
Resist Acoustical Panels
2. Core Fiberglass Density: 6 pcf. 3. Core Thickness: 1-1/8 inches. 4. Core Thickness: 2-1/8 inches. 5. Width: 24-48 inches and custom. 6. Length: 24-120 inches and custom. 7. Corners: Square. 8. Corners: Radiused. 9. Edge Profile: Square. 10. Edge Profile: Half-bevel. 11. Edge Profile: Full-bevel. 12. Edge Profile: Miter. 13. Edge Treatment: Edges un-hardened. 14. Edge Treatment: Resin hardened. 15. Corners: Fully tailored. 16. Finish: Manufacturer, pattern and color as selected; applied directly over face and edges of panel and returned
to back of panel to provide full finished edge; corners fully tailored. 17. Classic Resist Panel Finish: Whispertex Plisse fabric for nominal 1-1/8 inch and 2-1/8 inch thickness. 18. Mounting Type: Adhesive / Resin. 19. Mounting Type: Adhesive No Resin. 20. Mounting Type: Impaling / Adhesive. 21. Mounting Type: Lay-in. 22. Mounting Type: Magnet. 23. Mounting Type: Spline. 24. Mounting Type: Velcro. 25. Mounting Type: Panel Clip to Z-Bar. 26. Mounting Type: Panel Clip to Double Wall Clip. 27. Mounting Type: Z-Bar to Z-Bar. 28. Mounting Type: Aluminum Z-Clip. 29. Mounting Type: Panel Clip / Velcro. 30. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 31. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 32. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1-1/8 inch Thickness: 0.85.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries..
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Respond A100 Series Acoustical Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsid-iary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and spe-cifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop draw-ings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond A100 Series Acoustical Panels
1. Construction: Composite core of dimensionally stable rigid fiberglass. 2. Fiberglass Density: 6 - 7 pcf. 3. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 4. Core Thickness: 1/2 inch. 5. Core Thickness: 3/4 inch. 6. Core Thickness: 1 inch. 7. Core Thickness: 1-1/2 inches. 8. Core Thickness: 2 inches.
-
Respond A100 Series Acoustical Panels
9. Core Thickness: 3 inches. 10. Core Thickness: 4 inches. 11. Width: 24-48 inches. 12. Length: 24-120 inches. 13. Corners: Square. 14. Corners: Radiused. 15. Edge Profile: Square. 16. Edge Profile: Radius. 17. Edge Profile: Half-bevel. 18. Edge Profile: Full-bevel. 19. Edge Profile: Miter for corner conditions. 20. Edge Treatment: Resin hardened. 21. Edge Treatment: Aluminum for square edge only. 22. Edge Treatment: High-pressure laminate, for square edge only. 23. Fabric Finish: Manufacturer, pattern and color as selected; applied directly over face and edges of panels to
provide full finished edge, fully tailored corners. 24. Mounting Type: Adhesive / Resin. 25. Mounting Type: Adhesive No Resin. 26. Mounting Type: Impaling / Adhesive. 27. Mounting Type: Lay-in. 28. Mounting Type: Magnet. 29. Mounting Type: Spline. 30. Mounting Type: Velcro. 31. Mounting Type: Panel Clip to Z-Bar. 32. Mounting Type: Panel Clip to Double Wall Clip. 33. Mounting Type: Z-Bar to Z-Bar. 34. Mounting Type: Aluminum Z-Clip. 35. Mounting Type: Panel Clip / Velcro. 36. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 37. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 38. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1/2 inch thickness: 0.55. b. Noise Reduction Coefficient (NRC) for 3/4 inch Thickness: 0.70. c. Noise Reduction Coefficient (NRC) for 1 inch Thickness: 0.80. d. Noise Reduction Coefficient (NRC) for 1-1/2 inch Thickness: 0.95. e. Noise Reduction Coefficient (NRC) for 2 inch Thickness: 1.05. f. Noise Reduction Coefficient (NRC) for 3 inch Thickness: 1.10.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Respond IR108 Series Acoustical Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond IR108 Series Acoustical Panels
1. Construction: Composite core of dimensionally stable rigid fiberglass, laminated with impact resistant 16-20 pcf molded glass fiber.
2. Core Fiberglass Density: 6 - 7 pcf. 3. Cores laminated with 1/8 inch layer of 16 - 20 pcf molded glass fiber. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 5/8 inch. 6. Core Thickness: 7/8 inches. 7. Core Thickness: 1-1/8 inches. 8. Core Thickness: 1-5/8 inch. 9. Core Thickness: 2-1/8 inch.
-
Respond IR108 Series Acoustical Panels
10. Core Thickness: 3-1/8 inches. 11. Core Thickness: 4-1/8 inches. 12. Manufacturing Tolerances: Standard +/- 1/16 inch for width and length. 13. Width: 24-60 inches and custom. 14. Length: 24-120 inches and custom. 15. Corners: Square. 16. Corners: Radiused. 17. Edge Profile: Square. 18. Edge Profile: Radius. 19. Edge Profile: Half-bevel. 20. Edge Profile: Full-bevel. 21. Edge Profile: Miter for corner conditions. 22. Edge Treatment: Resin hardened. 23. Edge Treatment: Aluminum. 24. Edge Treatment: High-pressure laminate, for square edge only. 25. Edge Treatment: Wood. 26. Fabric Finish: Manufacturer, pattern and color as selected; applied directly over face and edges of panels to
provide full finished edge, fully tailored corners. 27. Mounting Type: Adhesive / Resin. 28. Mounting Type: Adhesive No Resin. 29. Mounting Type: Impaling / Adhesive. 30. Mounting Type: Lay-in. 31. Mounting Type: Magnet. 32. Mounting Type: Spline. 33. Mounting Type: Velcro. 34. Mounting Type: Panel Clip to Z-Bar. 35. Mounting Type: Panel Clip to Double Wall Clip. 36. Mounting Type: Z-Bar to Z-Bar. 37. Mounting Type: Aluminum Z-Clip. 38. Mounting Type: Panel-Clip / Velcro. 39. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 40. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 41. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type F5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 5/8 inch Thickness: 0.70. b. Noise Reduction Coefficient (NRC) for 7/8 inch Thickness: 0.80. c. Noise Reduction Coefficient (NRC) for 1-1/8 inch Thickness: 0.90. d. Noise Reduction Coefficient (NRC) for 1-5/8 inch Thickness: 1.00. e. Noise Reduction Coefficient (NRC) for 2-1/8 inch Thickness: 1.05. f. Noise Reduction Coefficient (NRC) for 3-1/8 inch Thickness: 1.05.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Respond TK/AC Acoustical Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond TK/AC Acoustical Panels
1. Construction: Single core of dimensionally stable mineral fiber board.
-
Respond TK/AC Acoustical Panels
2. Core Mineral Fiber Density: 16.8 pcf and 22 pcf. 3. Core Materials: Maximum 0.1 percent hygrometric expansion from 50 - 90 percent RH. 4. Recycled Content: For mineral fiber board, 50 percent total; 32 percent pre-consumer recycled content, 18
percent post-consumer recycled content. 5. Core Thickness and Density: 5/8 inch, 22 pcf. 6. Core Thickness and Density: 1/2 inch, 16.8 pcf. 7. Manufacturing Tolerances: Standard +/- 1/16 inch for width and length. 8. Width: 24-48 inches and custom. 9. Length: 24-120 inches and custom. 10. Edge Profile: Square. 11. Edge Profile: Radius. 12. Edge Profile: Half-bevel. 13. Edge Profile: Miter. 14. Edge Profile: Kerf. 15. Corners: Square. 16. Corners: Radiused. 17. Corners: Fully tailored. 18. Finish: Manufacturer, pattern and color as selected; applied directly over face and edges of panel and returned
to back of panel to provide full finished edge; corners fully tailored. 19. Mounting Type: Adhesive / Resin (perimeter adhesive). 20. Mounting Type: Concealed spline. 21. Mounting Type: Velcro. 22. Mounting Type: Z-Clip Plates and Wall Bars. 23. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 24. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC): Based on manufacturers typical data.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Access Ceiling System
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive ceilings.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE CEILINGS
A. Basis-of-Design: Conwed Designscape | Wall Technology Access Ceiling
-
Access Ceiling System
1. Core Fiberglass Density: 6 - 7 pcf. 2. Core laminated with 1/8 inch, 16 - 20 pcf molded glass fiber. 3. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 4. Assembly Accessories: Access or Conceil grid system. 5. Core Thickness: 1-1/8 inches. 6. Flat Panels, Width: 48-60 inches. 7. Flat Panels, Length: 24-144 inches. 8. Edge Profile: Slightly beveled to create 1/8 inch reveal. 9. Edge Profile: 4 inch integral returned edges. 10. Edge Profile: 6 inch integral returned edges. 11. Finish Type and Color: Soft Texture finish, white. 12. Finish Type and Color: Subtle Texture finish, black, over acoustically transparent membrane. 13. Finish Type and Color: Custom Paint Color. 14. Fabric Finish: _______________. (for optional fabric finish, specify manufacturer, type, pattern and color) 15. Mounting Type: Torsion spring mounting, extruded aluminum grid mains and V-shaped spacer bars. 16. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 17. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 18. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type E400
Mounting) and vary by panel finish. a. Noise Reduction Coefficient (NRC) for 1-1/8 inch Thickness: 0.90.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Foundations Ceiling Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive ceilings.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMTIED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE CEILINGS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond Foundations Acoustical Ceiling Panels.
-
Foundations Ceiling Panels
1. Core Fiberglass Density: 6 - 7 pcf. 2. Core laminated with 1/8 inch, 16 - 20 pcf molded glass fiber. 3. Assembly Accessories: Provide optional kerfs/splines for abutting square-edge panels. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 1-1/8 inches. 6. Core Thickness: 1-5/8 inches. 7. Core Thickness: 2-1/8 inches. 8. Core Thickness: 3-1/8 inches. 9. Core Thickness: 4-1/8 inches. 10. Width: 24-48 inches. 11. Length: 24-120 inches. 12. Corners: Square. 13. Edge Profile: Square. 14. Edge Profile: Full bevel. 15. Edge Profile: Half-bevel. 16. Edge Treatment: Resin hardened. 17. Corners: Fully tailored. 18. Finish Type and Color: Soft Texture finish, white. 19. Mounting Type: Lay-in. 20. Mounting Type: Z-Bar to Z-Bar. 21. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 22. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 23. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type E400
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1-1/8 inch Thickness: 0.90. b. Noise Reduction Coefficient (NRC) for 2-1/8 inch Thickness: 1.10.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Gridlock Ceiling Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive ceilings.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE CEILINGS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond Gridlock Acoustical Ceiling
-
Gridlock Ceiling Panels
1. Core Fiberglass Density: 6 - 7 pcf. Optionally laminated cores with 1/8 inch thick. 16 20 pcf molded fiberglass / High Impact facer.
2. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 3. Edge Treatment: Resin hardened. 4. Core Thickness and Edge: 1 inch thick, square edge profile. 5. Core Thickness and Edge: 1-1/8 inches thick, square edge profile, High Impact facer. 6. Core Thickness and Edge: 1-1/2 inches thick, square edge profile. 7. Core Thickness and Edge: 1-5/8 inches thick, square edge profile, High Impact facer. 8. Core Thickness and Edge: 2 inches, square edge profile. 9. Core Thickness and Edge: 2-1/8 inches, square edge profile, High Impact facer. 10. Width: 24-30 inches. 11. Length: 24-60 inches, and custom. 12. Finish Type and Color: Soft Texture finish, white. 13. Finish Type and Color: Subtle Texture finish, over acoustically transparent membrane, standard white. 14. Fabric Finish: _______________. (for optional fabric finish, specify manufacturer, type, pattern and color) 15. Mounting: Lift-and-shift Gridlock. 16. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 17. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 18. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type E400
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC): Per manufacturers data.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
New Dimensions Ceiling Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive ceilings.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE CEILINGS
A. Basis-of-Design: Conwed Designscape | Wall Technology New Dimensions Acoustical Ceiling Panels.
1. Core Fiberglass Density: 6 - 7 pcf.
-
New Dimensions Ceiling Panels
2. Core laminated with 1/8 inch, 16 - 20 pcf molded glass fiber. 3. Assembly Accessories: Provide optional kerfs/splines for abutting square-edge panels. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 1-1/8 inches. 6. Core Thickness: 1-5/8 inches. 7. Core Thickness: 2-1/8 inches. 8. Core Thickness: 3-1/8 inches. 9. Core Thickness: 4-1/8 inches. 10. Width: 24-48 inches. 11. Length: 24-120 inches. 12. Corners: Square. 13. Edge Profile: Square. 14. Edge Profile: Full bevel. 15. Edge Profile: Half-bevel. 16. Edge Treatment: Resin hardened. 17. Corners: Fully tailored. 18. Finish Type and Color: Soft Texture finish, white. Standard. 19. Finish Type and Color: Custom Paint Colors. 20. Mounting Type: Lay-in. 21. Mounting Type: Z-Bar to Z-Bar. 22. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 23. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 24. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type E400
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1-1/8 inch Thickness: 0.90. b. Noise Reduction Coefficient (NRC) for 2-1/8 inch Thickness: 1.10.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Respond Curved Reflective Ceiling Clouds
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive ceilings.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE CEILINGS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond Curved Reflective Ceiling Clouds
-
Respond Curved Reflective Ceiling Clouds
1. Construction: Acoustical Panels shall be constructed of medium density overlay (MDO) plywood or Medium Density Fiberboard (MDF) backed by 1 inch x 1 inch pre-curved metal ribs.
2. Thickness: 3/4 inch. 3. Assembly Accessories: Joining plates for abutting panels for use with proprietary joining and leveling system. 4. Width: 24-48 inches and custom. 5. Length: 24-120 inches and custom. 6. Corners: Square. 7. Corners: Radius. 8. Edge Profile: Square. 9. Finish, Gel-Coat: Manufacturer, pattern and color as selected; gel-coat applied directly over face and edges of
panel. 10. Finish, Fabric: Manufacturer, pattern and color as selected; fabric returned to back of panel to provide full
finished edge; corners fully tailored. 11. Mounting Type: Standard, direct attachment to exposed metal frame with self-drilling acoustical hangers. 12. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC): Per manufacturers data.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Respond Reflector Ceiling Clouds, Flat
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive ceilings.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE CEILINGS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond Reflector Ceiling Clouds, Flat
1. Construction: Medium density overlay (MDO) plywood or Medium Density Fiberboard (MDF).
-
Respond Reflector Ceiling Clouds, Flat
2. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 3. Medium Density Overlay (MDO) Thickness: 1/2 inch. 4. Medium Density Overlay (MDO) Thickness: 3/4 inch. 5. Backing Thickness: 1 inch. 6. Backing Thickness: 1-1/2 inches. 7. Backing Thickness: 2 inches. 8. Backing Thickness: Custom. 9. Width: 24-48 inches and custom. 10. Length: 24-120 inches and custom. 11. Corners: Square. 12. Corners: Radius. 13. Edge Profile: Square. 14. Edge Profile: 1/2 inch bevel. 15. Finish: Manufacturer, pattern and color as selected; gel-coat applied directly over face and edges of panel and
returned to back of panel to provide full finished edge; corners are fully tailored. 16. Mounting Type for Flat Reflectors: Standard, cloud angle.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Skyway Ceiling Clouds Type I & II
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE CEILINGS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive ceilings.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE CEILINGS
A. Basis-of-Design: Conwed Designscape | Wall Technology Skyway Ceiling Clouds
1. Construction: Composite core of dimensionally stable rigid fiberglass.
-
Skyway Ceiling Clouds Type I & II
2. Core Fiberglass Density: 6 - 7 pcf. 3. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 4. Fiberglass Facings: 1/8 inch thick layer of 16 - 20 pcf molded fiberglass on face and back. 5. Core Thickness: 1-1/4 inch. 6. Core Thickness: 2-1/4 inches. 7. Width: 24-48 inches and custom. 8. Length: 24-120 inches and custom. 9. Corners: Square. 10. Edges: Square. 11. Finish Type and Color: Soft Texture White. 12. Finish Type and Color: Foundations White 13. Finish Type and Color: Subtle Texture White or Custom. 14. Finish Type and Color: New Dimensions White or Custom. 15. Edge Treatment: Resin hardened. 16. Finish: Manufacturer, pattern and color as selected: applied directly over face and edges of panel and returned
to back of panel to provide full finished edge; corners fully tailored. 17. Mounting Type: Standard, direct attachment to resin spots with self-drilling acoustical hangers or grid (by
others). 18. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 19. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 20. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish a. Noise Reduction Coefficient (NRC) for 1-1/8 inch thickness: 0.90. b. Noise Reduction Coefficient (NRC) for 2-1/8 inch thickness: 1.10.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Loaded Vinyl Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Loaded Vinyl Panels
-
Loaded Vinyl Panels
1. Construction: Composite core construction of dimensionally stable rigid fiberglass backed by 1/8 inch loaded vinyl barrier, fully adhered to fiberglass.
2. Core Fiberglass Density: 6 - 7 pcf. 3. Provide optionally laminated cores with 1/8 inch thick, 16 - 20 pcf molded fiberglass. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 7/8 inch. 6. Core Thickness: 1 inch with High Impact facer. 7. Core Thickness: 1-1/8 inches. 8. Core Thickness: 1-1/4 inches with High Impact facer.. 9. Core Thickness: 1-5/8 inches. 10. Core Thickness: 1-3/4 inches with High Impact facer.. 11. Core Thickness: 2-1/2 inches. 12. Core Thickness: 2-3/8 inches with High Impact facer.. 13. Width: 24-47 inches and custom. 14. Length: 24-120 inches and custom. 15. Corners: Square. 16. Edge Profile: Square. 17. Edge Profile: Radius. 18. Edge Profile: Half-bevel. 19. Edge Profile: Full-bevel. 20. Edge Profile: Miter for corner conditions. 21. Edge Treatment: Resin hardened. 22. Edge Treatment: Aluminum for square edge only. 23. Edge Treatment: High-pressure laminate, for square edge only. 24. Fabric Finish: Manufacturer, pattern and color as selected; applied directly over face and edges of panels to
provide full finished edge, fully tailored corners. 25. Mounting Type: Perimeter adhesive. 26. Mounting Type: Panel clip. 27. Mounting Type: Concealed splines for walls. 28. Mounting Type: Z-Bar to Z-Bar. 29. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 30. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 31. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC): Per manufacturers data. b. Sound Transmission Coefficient (STC): 27 for loaded vinyl.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries..
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Low Frequency Tuner Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE SPECIALTY PRODUCTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Low frequency tuner panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 LOW FREQUENCY TUNER PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Respond Low Frequency Tuner Panels
-
Low Frequency Tuner Panels
1. Construction: Composite core of dimensionally stable rigid fiberglass laminated to an unperforated vinyl member that allows selective acoustical transparency.
2. Core Fiberglass Density: 6 - 7 pcf. 3. Thickness: 2 inches. 4. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 5. Core Thickness: 2 inches. 6. Width: 24-48 inches and custom. 7. Length: 24-120 inches and custom. 8. Corners: Square. 9. Corners: Radiused. 10. Edge Profile: Square. 11. Edge Profile: Radius. 12. Edge Profile: Half-bevel. 13. Edge Profile: Full-bevel. 14. Edge Profile: Miter, for corner conditions. 15. Edge Treatment: Resin hardened. 16. Edge Treatment: Aluminum for square edge only. 17. Edge Treatment: High-pressure laminate, for square edge only. 18. Fabric Finish: Manufacturer, pattern and color as selected; applied directly over face and edges of panels to
provide full finished edge, fully tailored corners. 19. Mounting Type: Adhesive / Resin. 20. Mounting Type: Adhesive No Resin. 21. Mounting Type: Impaling / Adhesive. 22. Mounting Type: Lay-in. 23. Mounting Type: Magnet. 24. Mounting Type: Spline. 25. Mounting Type: Velcro. 26. Mounting Type: Panel-Clip to Z-Bar. 27. Mounting Type: Panel-Clip to Double Wall Clip. 28. Mounting Type: Z-Bar to Z-Bar. 29. Mounting Type: Aluminum Z-Clip. 30. Mounting Type: Panel Clip / Velcro. 31. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 32. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 33. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC): No less than 0.30, no greater than 0.40.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Metro Rebound Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier). Sections of this guide should be included, edited, or omitted based on the requirements of a specific project. It is the responsibility of both the specifier and the purchaser to determine if a product or system is suitable for its intended use. Neither Owens Corning, nor any of its subsidiary or affiliated companies, assume any responsibility for the content of this specification guide relative to actual projects and specifically disclaim any and all liability for any errors or omissions in design, detail, structural capability, attachment details, shop drawings or other construction related details, whether based upon the information provided by Owens Corning or otherwise.
SECTION 098410 SOUND ABSORPTIVE WALL PANELS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes: Sound absorptive wall panels.
B. Related Work: The following items are not included in this Section and are specified under the designated Sections:
1. Section 092100 PLASTER AND GYPSUM BOARD ASSEMBLIES for plaster and gypsum board walls and ceilings.
1.2 SUBMITTALS
A. Product Data: Submit manufacturers product data including certified laboratory test reports and other data required to show compliance with these specifications.
B. Samples: Submit 11-1/2 by 11-1/2 inch samples of representative panel with factory detailed edge, and representative samples of mounting devices.
1.3 QUALITY ASSURANCE
A. Pre-installation Conference: Conduct conference at Project site to comply with requirements in Division 01.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Project Conditions: Protect system components from excessive moisture in shipment, storage, and handling. Deliver in unopened bundles and store in a dry place with adequate air circulation. Do not deliver material to building until wet conditions such as concrete, plaster, paint, and adhesives have been completed and cured to a condition of equilibrium.
1.5 LIMITED WARRANTY
A. Limited Warranty: Provide manufacturers standard limited 3-year warranty against manufacturing defects in material or workmanship.
PART 2 - PRODUCTS
2.1 SOUND ABSORPTIVE WALL PANELS
A. Basis-of-Design: Conwed Designscape | Wall Technology Metro Rebound Panels
1. Construction: Composite core of dimensionally stable rigid fiberglass.
-
Metro Rebound Panels
2. Core Fiberglass Density: 6 - 7 pcf. 3. Recycled Content: For fiberglass, 52 percent pre-consumer and 5 percent post-consumer recycled content. 4. Core laminated with 1/16 inch, resilient perforated co-polymer face sheet. 5. Core Thickness: 1-1/16 inches. 6. Core Thickness: 1-9/16 inches. 7. Core Thickness: 2-1/16 inches. 8. Width: 24-48 inches and custom. 9. Length: 24-116 inches and custom. 10. Corners: Square. 11. Edge Profile: Square. 12. Edge Treatment: Resin hardened beneath heat-formed co-polymer. 13. Finish: Copolymer applied directly to face and edges and face of panels, color as selected. 14. Mounting Type: Adhesive / Resin. 15. Mounting Type: Impaling / Adhesive / Resin. 16. Mounting Type: Lay-in. 17. Mounting Type: Magnet. 18. Mounting Type: Velcro. 19. Mounting Type: Panel Clip to Z-Bar. 20. Mounting Type: Panel Clip to Double Wall Clip. 21. Mounting Type: Z-Bar to Z-Bar. 22. Mounting Type: Aluminum Z-Clip. 23. Mounting Type: Panel-Clip / Velcro. 24. Flammability (ASTM E 84): Panel components shall have a Class A rating per ASTM E 84. 25. Resistivity To Heat Or Cold: R-factor of 4.16 per inch of thickness. 26. Acoustical Performance: Values below are for panels mounted in accordance with ASTM C 423 (Type D5
Mounting) and vary by panel thickness and finish. a. Noise Reduction Coefficient (NRC) for 1-1/16 inch Thickness: 0.75. b. Noise Reduction Coefficient (NRC) for 2-1/16 inch Thickness: 0.95.
PART 3 - EXECUTION
3.1 INSTALLATION
A. Verify wet work such as plastering and concrete is complete and dry. Verify building is enclosed and under standard occupancy conditions (60 - 85 degrees F and not more than 70 percent relative humidity) prior to start of installation. Commencement of installation constitutes Installers acceptance of surfaces and conditions.
B. Install products in accordance with manufacturers written instructions and in proper relationship with adjacent construction, including the following:
1. For adhesive installation to substrate, provide temporary support to prevent panel slippage. Note: Impaling clips are designed to help hold panels in place until adhesive dries.
C. Touch-up, repair or replace damaged units until satisfactory results are obtained.
END OF SECTION
2014 Owens Corning. All Rights Reserved.
-
Reflective Wall Panels
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment. This guide is to aid in the creation of a complete building specification that is to be fully reviewed and edited by the architect of record (specifier).