flexa accelerator (vfa) quick guide data source: asm ... vayo flexa accelerator 7/21 5 - help...

21
Flexa Accelerator (VFA) Quick Guide Data Source: ASM Program (*.sipro,*.xml) Doc Revision: V3.4 Update on: 2016/7/28 www.vayoinfo.com

Upload: others

Post on 17-Apr-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Flexa Accelerator (VFA)

Quick Guide

Data Source: ASM Program (*.sipro,*.xml)

Doc Revision: V3.4 Update on: 2016/7/28

www.vayoinfo.com

Page 2: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 2/21

Table of Contents

1. About Vayo Flexa Accelerator ...........................................3

2. Data Source Requirement .................................................3

3. How to start VFA ................................................................4

4. Flow Chart (Step by step guide) ........................................5

4.1. Default work flow chart: ......................................................................... 5

4.2. Explanation of Flow Chat ....................................................................... 5

4.3. Required procedures for ASM’s program data source .............................. 7

5. How to generate Fuji Flexa job with ASM’s program ........7

5.1. Create New Vayo Job with program input ............................................... 7

5.2. Gerber Import (Optional) ...................................................................... 11

5.3. Mark Setting (Optional) ........................................................................ 11

5.4. Part Data Editor (Optional) ................................................................... 12

5.5. PCB Orientation Setting (Optional) ....................................................... 13

5.6. Parts Verification (Optional) ................................................................. 14

5.7. Generate Fuji Flexa Job ...................................................................... 14

6. How to do line balancer and optimizer in Fuji Flexa system

17

6.1. Select line for job ................................................................................ 17

6.2. Line balancer for job ............................................................................ 18

6.3. Line Optimizer for job .......................................................................... 19

7. How to get support ...........................................................21

Page 3: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 3/21

1. About Vayo Flexa Accelerator

Vayo Flexa Accelerator (VFA) software accelerates Fuji Flexa programming with intelligent, automatic & no-brainer approach. Flexa Accelerator enables Fuji Flexa to import varies PCB CAD/Gerber & BOM, SMT Programs; utilizes design information in maximum; intelligently match existing part data & create new part data; automatic correct parts angle & position; generate output directly to Flexa Job. It leverages the whole Fuji placement programming process, which reduce programming cycle reduce machine occupy time to new product introduction. Therefore it saves manufacturing and labor cost.

2. Data Source Requirement

Data source: 2.1: ASM/SiPlace’s program which is from Siplace pro programming system of ASM 2.2: Sample data is located at \Vayo-Flexa Accelerator\Data\SampleData\3_ASM_Program

2.2.1: Sipro File: Vayo1152084.sipro 2.2.2: XML File: N011360-PANEL_B.xml

How to export ASM’s program from Siplace Pro system: 1) Open SIPLACE Pro Desk software, select the desired output of the program in Job Tree View, or

Recipe Tree View interface, right-select "Data Model Export ...";

2) Select the output path, click "Save". (“*.Sipro” is the format of output program with version of Pro

V7.0 or higher than Pro V7.0, “* xml” is the format of output program with version lower than Pro V7.0.)

Note: If the picture is used to infringe the copyright owners, please notify us in time, I will promptly delete!

Page 4: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 4/21

3. How to start VFA

When you finished installing VFA and active it, you will see a new shortcut in Fuji Flexa Director, so you can start VFA over here every time.

Note: You can also find it in your folder where you have installed: \Vayo-Flexa Accelerator\VFA.exe

Page 5: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 5/21

4. Flow Chart (Step by step guide)

4.1. Default work flow chart:

Note:

1. There are total 11 steps according to diffirent data source input;

2. For Gerber Inpu step,it’s optional according to your data source,if you import pcb CAD or SMT program data, maybe you need to skip this step.

3. It supports to customized flow chart if needed, but get Vayo’s support.

4.2. Explanation of Flow Chat

A step by step flow chart is offered to ease the operation (Ctrl+F1 to show flow chart if close); the default flow chart appears as below: Flow chart file name: VFA-process-EN.txt, or refer below picture:

Page 6: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 6/21

1 - Flow chart name; 2 - Flag upon the step has already been accomplished; 3 - Step name; 4 - Function button (Click to execute this step.);

1

2

3

4

5

Page 7: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 7/21

5 - Help information (Instructions for selected step).

Note: To switch to different flow chat, go to menu Process-> Select Process Flow.

4.3. Required procedures for ASM’s program data source

1. Create new job with program input step 1: Program Import

2. Import Gerber layer for reference (Optional) step 2: Gerber import

3. Confirm or set Mark point (Optional) step 5: Mark Setting

4. Smart to assign PD and correct angle for parts: step 7: Part Data Editor

6. Set PCB reflow orientation: step 8: PCB Orientation

7. Finally verify PD/Polarity/Position of parts: step 9: Part Verification

8. Generate Flexa Job: step 10: Generate Flexa job to Flexa step 11: Generate Flexa job to hard disk.

5. How to generate Fuji Flexa job with ASM’s program

5.1. Create New Vayo Job with program input

Menu: File->New Job To start a new project, you must create a Vayo Job firstly; all inputs shall be saved to this Job. 1) File-> New Job, or click on below icon to create a new Job;

2) Click “Select Files” to select program file, and it will auto give job name based on file name;

Page 8: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 8/21

Note: if it does NOT identify the CAD/program format, please select the corresponding format

manually from the CAD/program Interface list. 3) Click “Import” to parse selected program and popup window:

4) Select one of list.

Page 9: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 9/21

a. select one recipe of listed, If there is no recipe, please confirm the data sourse is right (VFA only

support program exported by job and recipe); b. ticked “add prefix “skip_” for skip components: skip_xxx c. click “load” to parse program data

click “close” when you see “End!” from message box. 5) Click “Next” to save the inputted program data to the Job if graphic is correct.

Page 10: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 10/21

To main Interface:

Note: if the buttons is enbaled, it show with base job. if Bottuns is disabled, it show with panel job, you can right-click the single board name to “Switch to Base Job” to edit, or export panel Flexa directly.

Page 11: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 11/21

5.2. Gerber Import (Optional)

Note: Generally, Don’t need to do this step. You can import Gerber layer for reference if needed. Flow chart: Gerber Import Menu: Process-> Gerber & XY-> Gerber Import Please refer details of Gerber Import from manual “Vayo-Flexa Accelerator Quick Guide V3.4.pdf)

5.3. Mark Setting (Optional)

Note: Generally, Don’t need to do this step. The program must contains fiducial marks, if you want to double check them, please click this step to validate marks as below: Flow chart: Mark Setting Menu: Graphical-> Mark & Origin-> Create Mark Shortcut Key: R

Page 12: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 12/21

If there aren’t any marks, please do “Mark Setting” step to set fiducial marks for SMT/Placement program. Please refer details of Mark Setting from manual “Vayo-Flexa Accelerator Quick Guide V3.4.pdf”

5.4. Part Data Editor (Optional)

Note: Generally, Don’t need to do this step. You can double validate/re-assign part data if needed. Flow chart: Part Data Editor Menu: Process-> Part Data Editor

Page 13: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 13/21

If you need to re-assign part data or package to Part number, please refer details of “Part data editor”

section from manual “Vayo-Flexa Accelerator Quick Guide Vx.x.pdf)

5.5. PCB Orientation Setting (Optional)

Note: Generally, don’t need to do this step. If you need to change the orientation, please do following procedure. Flow chart step 8: PCB Orientation setting Menu: Graphical-> PCB Orientation setting

Page 14: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 14/21

5.6. Parts Verification (Optional)

Note: Generally, Don’t need to do this step. You can double verify it, or import Gerber layers for reference. Flow chart step 9: Parts Verification Menu: Process-> Parts Verification

Please refer details of Parts Verification from manual “Vayo-Flexa Accelerator Quick Guide V3.4.pdf”

5.7. Generate Fuji Flexa Job

Flow chart step 9: Flexa Job to system Menu: Process-> Flexa Job to system Output the Job to Fuji Flexa directly Select Job group, and assign Job name and its version, and click “ok”

Options setting for generation:

Page 15: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 15/21

Note: please select options according to your needs.

Once the output is completed successfully, you shall see the Job in Fuji Flexa Director. Note: you might need to press shortcut key F5 to refresh the Job list in Flexa.

Page 16: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 16/21

Output the Job to local disk:

If Accelerator is installed offline, then you can output a Flexa Job to your local disk and then copy and

input it to Flexa system.

Page 17: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 17/21

6. How to do line balancer and optimizer in Fuji Flexa system

6.1. Select line for job

Select line:

Page 18: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 18/21

6.2. Line balancer for job

Right click for line balancer


Click “start” to do line balancer

Page 19: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 19/21

Line Balancer was completed

6.3. Line Optimizer for job

Right click for Optimizer


Page 20: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 20/21

Start to do optimizer


Page 21: Flexa Accelerator (VFA) Quick Guide Data Source: ASM ... Vayo Flexa Accelerator 7/21 5 - Help information (Instructions for selected step). Note:To switch to different flow chat, go

Vayo Flexa Accelerator

www.vayoinfo.com 21/21

7. How to get support

You can contact your local vendor to get support or send an email to [email protected] Contact Information: Vayo (Shanghai) Technology Co., Ltd. Phone: +86-21-61182128 Email: [email protected] Visit us at www.vayoinfo.com