Load-bearing sheetDrawings - list of contents (page 1/2)
Drawing nr. Content of drawing (load-bearing sheets) Date Rev. date
T45-30L-905_V Load-bearing sheet T45-30L-905, Technical dwg, Section - Center line 16.7.2007 7.4.2011T70-57L-846_V 16.7.2007 7.4.2011
16.7.2007 7.4.2011
T153-40L-840_V 16.7.2007 7.4.2011
T70-57L-1058_V
Load-bearing sheet - Insulated roof, Erection - General view 18.10.2005
IN 02 18.10.2005 7.4.2011
IN 03IN 04IN 05IN 06IN 07IN 08IN 09IN 10IN 11IN 12IN 13IN 14IN 15IN 16IN 17IN 18IN 19IN 20IN 21IN 22IN 23IN 24IN 25IN 26IN 27IN 28IN 29IN 30IN 31IN 32IN 33IN 34IN 35
IN 01
Load-bearing sheet T70-57L-846, Technical dwg, Section - Center lineLoad-bearing sheet T70-57L-1058, Technical dwg, Section - Center line
Load-bearing sheet T153-40L-840, Technical dwg, Section - Center line
Load-bearing sheet - Insulated roof, Installation - Fastening to support
Load-bearing sheet - Insulated roof, Installation - Endlap 18.10.2005 7.4.201118.10.2005 7.4.2011Load-bearing sheet - Insulated roof, Installation - Fastening to support
Load-bearing sheet - Insulated roof, Installation - Static scheme 18.10.2005 7.4.2011Load-bearing sheet - Insulated roof, Installation - Static scheme 18.10.2005 7.4.2011Load-bearing sheet - Insulated roof, Installation - Simple overlap 7.4.2011
7.4.2011Load-bearing sheet - Insulated roof, Installation - Simple overlap7.4.20117.4.2011
Load-bearing sheet - Insulated roof, Installation - Supporting piece 18.10.2005 7.4.2011Load-bearing sheet - Insulated roof, Installation - Supporting piece 18.10.2005 7.4.2011Load-bearing sheet - Insulated roof, Erection - Gerber system 18.10.2005 7.4.2011Load-bearing sheet - Insulated roof, Erection - Gerber system (endlap) 12.09.2005 7.4.2011Load-bearing sheet - Structural detail, Fastening to concrete 12.09.2005 7.4.2011Load-bearing sheet - Structural detail, Fastening to concrete/wood 12.09.2005 7.4.2011Load-bearing sheet - Structural detail, Fastening to prestressed concrete structures 12.09.2005 7.4.2011
12.09.2005 7.4.2011Load-bearing sheet - Structural detail, Fastening to prestressed concrete structuresLoad-bearing sheet - Insulated roof, Installation - Sidelap 18.10.2005 7.4.2011Load-bearing sheet - Insulated roof, Installation - Sidelap 18.10.2005 7.4.2011Load-bearing sheet - Structural detail, Flat roofs - 1 15.12.2000Load-bearing sheet - Structural detail, Flat roofs - 2 15.12.2000 4.8.2021Load-bearing sheet - Structural detail, Double pitched roofs or similar - 1 15.12.2000
Load-bearing sheet - Structural detail, Warehouse roofs - 1 15.12.2000 21.7.2011Load-bearing sheet - Structural detail, Warehouse roofs - 2 15.12.2000 21.7.2011Load-bearing sheet - Structural detail, Warehouse roofs - 3 15.12.2000 21.7.2011Load-bearing sheet - Structural detail, Warehouse roofs - 4 15.12.2000 21.7.2011
Load-bearing sheet - Structural detail, Double pitched roofs or similar - 2 15.12.2000Load-bearing sheet - Structural detail, Double pitched roofs or similar - 3 15.12.2000Load-bearing sheet - Structural detail, Double pitched roofs or similar - 4 15.12.2000Load-bearing sheet - Structural detail, Double pitched roofs or similar - 5 15.12.2000
Load-bearing sheet - Structural detail, Canopy and warehouse roofs 15.12.2000 21.7.2011Load-bearing sheet - Structural detail - 1 15.12.2000 4.8.2021Load-bearing sheet - Structural detail - 2 15.12.2000Load-bearing sheet - Structural detail - 3 15.12.2000Load-bearing sheet - Structural detail - 4 15.12.2000Load-bearing sheet - Structural detail - 5 15.12.2000
T130M-75L-930_V 16.10.2012Load-bearing sheet T130M-75L-930, Technical dwg, Section - Center line
4.8.2021
4.8.20214.8.20214.8.20214.8.20214.8.2021
4.8.20214.8.20214.8.20214.8.2021
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 00IN00A400021.7.2011
Ruukki
.
04.08.2021
.
IN00A4000
Load-bearing sheetDrawings - list of contents (page 2/2)
Drawing nr. Content of drawing (load-bearing sheets) Date Rev. date
IN 37IN 38IN 39IN 40IN 41IN 42IN 43IN 44
Load-bearing sheet - Structural detail, Light-weight intermediate floor 15.12.2000 21.7.2011Load-bearing sheet - Structural detail, Uninsulated walls - 1 15.12.2000 21.7.2011Load-bearing sheet - Structural detail, Uninsulated walls - 2 15.12.2000 21.7.2011Load-bearing sheet - Structural detail, Fastening of acoustic insulation wool - 1Load-bearing sheet - Structural detail, Fastening of acoustic insulation wool - 2Load-bearing sheet - Structural detail, OpeningLoad-bearing sheet - Structural detail, Supporting - 1Load-bearing sheet - Structural detail, Supporting - 2
15.12.2000 4.8.202115.12.2000 4.8.202115.12.2000 21.7.201115.12.2000 21.7.201115.12.2000 21.7.2011
IN 36 Load-bearing sheet - Structural detail, Intermediate floor 15.12.2000 21.7.2011
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheet T45-30L-905Technical DrawingSection - Center line
T45-30L-905_VTECDA4109Ruukki
1:5 TECD T45-30L-905
16.07.2007 07.04.2011
changed colour side
.
01
150.
8360
~957
905
9115
0.83
44
3030
Rautaruukki Corporation.CCopyright
colo
ur
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheet T70-57L-846Technical DrawingSection - Center line
T70-57L-846_VTECDA4118Ruukki
1:5 TECD T70-57L-846
16.07.2007 07.04.2011
changed colour side
.
01
211.
565
70
57
~914
45
846
147
211.
5
Rautaruukki Corporation.CCopyright
colo
ur
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheet T70-57L-1058Technical DrawingSection - Center line
T70-57L-1058_VTECDA4120Ruukki
1:5 TECD T70-57L-1058
16.07.2007 07.04.2011
changed colour side
.
01
211.
565
~109
1
1057
.5
147
211.
5
5745
70
colo
ur
Rautaruukki Corporation.CCopyright
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Rautaruukki Oyj. All rights reserved.CCopyright
TECDA4T30M
00T130M-75L-930 ViTECDA4T130M
Technical drawing - sectionTrapezoidal profileLoad bearing sheet T130M-75L-930
.
00
dd.mm.yy
1:5
Ruukki
16.10.2012
T130
M-7
5L-9
30
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheet T153-40L-840Technical DrawingSection - Center line
TECDA4125Ruukki
1:5 TECD T153-40L-840
16.07.2007 07.04.2011
changed colour side
.
01
280
117
~864
840
163
280
153
4062
T153-40L-840_V
colo
ur
Rautaruukki Corporation.CCopyright
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 01IN00A400118.10.2005
Ruukki
1:25
.
.
IN00A4001
2
Y
Y
1
3
Z
ZX X
L L
Rautaruukki Corporation.CCopyright
4
Section A - A
1
Section X - X75 mm 75 mm
150 mm
Sections Y-Y, Z-Z drawing no IN 02, IN 03
L - span length
L L
1 1
4 23
3 4
A
Detail A drawing no IN 04
3
** - side overlapping according to structural design
Attention:
* - fasteners installed according to structural design
2. Primary structure according to structural design3. Fastener in every flange against support
Load-bearing sheet - Insulated roofErection - General view
1. Ruukki load-bearing sheet
4. Fastener on sidelaps c\c max 500 mm
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 02IN00A400218.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4002
1
3
2
34
Load-bearing sheet - Insulated roofInstallation - Fastening to support
1
01
Section Y - Y
Rautaruukki Corporation.CCopyright
L - span length
** - side overlapping according to structural design
Attention:
* - fasteners installed according to structural design
2. Primary structure according to structural design3. Fastener in every flange against support
1. Ruukki load-bearing sheet
4. Fastener on sidelaps c\c max 500 mm
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 03IN00A400318.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4003
1
3
2
34
Section Z - Z
1
1 1
Load-bearing sheet - Insulated roofInstallation - Fastening to support
01
Rautaruukki Corporation.CCopyright
L - span length
** - side overlapping according to structural design
Attention:
* - fasteners installed according to structural design
2. Primary structure according to structural design3. Fastener in every flange against support
1. Ruukki load-bearing sheet
4. Fastener on sidelaps c\c max 500 mm
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 04IN00A400418.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4004
Detal A
75 mm 75 mm
150 mm
11
2
4 3
Z
Z
Section Z-Z drawing no IN 03
4
* - length and type of endlap according to structural design
Load-bearing sheet - Insulated roofInstallation - Endlap
Standard cross endlap of load-bearing sheets - Insulated roof
01
Rautaruukki Corporation.CCopyright
2. Primary structure according to structural design3. Fastener in every flange against support
1. Ruukki load-bearing sheet
4. Fastener on sidelaps c\c max 500 mm
Attention:
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 05IN00A400518.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4005
Standard static scheme - Insulated roof1-span system
Load-bearing sheet - Insulated roofInstallation - Static scheme
* - flange and fixing number according to structural design
01
Rautaruukki Corporation.CCopyright
2-span system
L L L L L
b b b b b b
b≈150mm
b/2
Continuous structure - simple overlap joint
L L L L L
b b b b b b
L/10
Continuous structure - double overlap joint
L L L L L
b b b b b b
b≈150mm
b/2
L L L L L
b b b b b b
L/10 L/10L/10
1. Ruukki load-bearing sheet2. Fastener on sidelaps c\c max 500 mm
Attention:
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 06IN00A400618.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4006
1-span system
Load-bearing sheet - Insulated roofInstallation - Static scheme
* - side overlapping and fastener number according to structural design
01
Rautaruukki Corporation.CCopyright
L L L L L
b b b b b b
b≈150mm
b/2
2-span system
L L L L L
b b b b b b
L L L L L
b b b b b b
L L L L L
b b b b b b
b≈150mm
b/2
L/10
Continuous structure - simple overlap joint
Continuous structure - double overlap joint
L/10 L/10L/10
Standard static scheme - Insulated roof
** - thicker sheet close to support
1. Ruukki load-bearing sheet2. Fastener on sidelaps c\c max 500 mm
Attention:
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 07IN00A400707.04.2011
Ruukki
1:5
07.04.2011
.
IN00A4007
e2=b/2 e1=0.1*L11
2
4 3
A
A
4
Load-bearing sheet - Insulated roofInstallation - Simple overlap
Standard simple overlap of load-bearing sheets - Insulated roof
01
Rautaruukki Corporation.CCopyright
L
>3d >3d
1
15
3
Section A - A
5
L - span length
** - number of fasteners according to structural design
Attention:
* - length and type of overlap according to structural design
2. Primary structure according to structural design3. Fastener in every flange against support
1. Ruukki load-bearing sheet
4. Fastener on sidelaps c\c max 500 mm5. Fastener in the web
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 08IN00A400807.04.2011
Ruukki
1:5
07.04.2011
.
IN00A4008
e1=0.1*L211
2
4 3
A
A
4
Load-bearing sheet - Insulated roofInstallation - Simple overlap
Standard simple overlap of load-bearing sheets - Insulated roof
01
Rautaruukki Corporation.CCopyright
L2
>3d >3d
1
15
3
Section A - A
5
>3d>3d
5
e1=0.1*L1
L1
4
L - span length
** - number of fasteners according to structural design
Attention:
* - length and type of overlap according to structural design
2. Primary structure according to structural design3. Fastener in every flange against support
1. Ruukki load-bearing sheet
4. Fastener on sidelaps c\c max 500 mm5. Fastener in the web
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 09IN00A400918.10.2005
Ruukki
.
07.04.2011
.
IN00A4009
Rautaruukki Corporation.CCopyright
1
3
2
Load-bearing sheet - Insulated roofErection - Supporting piece
2. Supporting piece 320mm length - Ruukki profile3. Primary structure according to structural design
1. Ruukki load-bearing sheet
01
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawingLoad-bearing sheet - Insulated roofErection - Supporting piece
IN 10IN00A401018.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4010
Rautaruukki Corporation.CCopyright
3
4
A
320 mm1
A
3
1
2
2
Section A - A
4
Section B - B
B
B
01
2. Supporting piece 320mm length - Ruukki profile1. Ruukki load-bearing sheet
3. Primary structure according to structural design4. Fastener in every flange against support
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 11IN00A401118.10.2005
Ruukki
.
07.04.2011
.
IN00A4011
L L L L L
L L L L L
X1 X2 X2 X12.
1.
L L L L L
X3 X43.
L L L L
4.
X3X4
X3 X4 X1
Attention:X1 = 0,125 x LX2 = 0,146 x LX3 = 0,204 x LX4 = 0,157 x LL - span length
Rautaruukki Corporation.CCopyright
A
A
Static scheme
A
Detail A drawing no IN 12
Load-bearing sheets - insulated profilesErection - Gerber system
01
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN00A401212.09.2005
Ruukki
1:5
07.04.2011
.
IN00A4012
min 150 mm1
1
1
75 mm 75 mm
4
5
min 3d
5
4
Rautaruukki Corporation.CCopyright
IN 12
Standard endlap of load-bearing sheets - Gerber system - insulated roof
2
3
Detail A
Section X - X
* - lenght, type of endlap, number of screws according to structural design
Section Y-Y drawing no IN 02
1 1
d-diameter of screw
Load-bearing sheets - insulated roofErection - Gerber system (endlap)
01
2. Primary structure according to structural design3. Fastener in every flange against support
1. Ruukki load-bearing sheet
4. Fastener5. Fastener for estetical reasons
Attention:
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN00A401312.09.2005
Ruukki
1:5
07.04.2011
.
IN00A4013
Rautaruukki Corporation.CCopyright
IN 13
Fastening of load-bearing sheet to concrete
Load-bearing sheets - structural detailFastening to concrete
01
3. Fastening of sheet can be done with e.g. spike metallic anchor + sealing4. The quality and number of fasteners according to structural designer specification
2. E.g. 5 mm thick sealing strip is installed between load-bearing sheet and concrete1. Fastening directly to concrete must be avoided
Attention:
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN00A401412.09.2005
Ruukki
1:5
07.04.2011
.
IN00A4014
Rautaruukki Corporation.CCopyright
IN 14
Fastening of load-bearing sheet to concrete/wood
Load-bearing sheets - structural detailFastening to concrete/wood
01
2. Load-bearing sheet is fastened to wood e.g. with self-drilling wood screws3. The quality and number of fasteners according to structural designer specification
1. Wood is installed onto concrete structure, fastening e.g. with wedge anchorsAttention:
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN00A401512.09.2005
Ruukki
1:5
07.04.2011
.
IN00A4015
Rautaruukki Corporation.CCopyright
IN 15
Fastening of load-bearing sheet to prestressed concrete structures
Load-bearing sheets - structural detailFastening to prestressed concrete structures
01
2. Load-bearing sheet is fastened to steel profile with e.g. self-drilling screws3. The quality and number of fasteners according to structural designer specification
1. Steel profile is installed onto concrete structure, fastening to fastening plates in the prestressed concrete structure
steel profile, non continuousrectangular hollow section orcold worked U-steel
t
Attention:
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN00A401612.09.2005
Ruukki
1:5
07.04.2011
.
IN00A4016
Rautaruukki Corporation.CCopyright
IN 16
Load-bearing sheets - structural detailFastening to prestressed concrete structures
01
2. Load-bearing sheet is fastened to wood with e.g. self-drilling wood screws3. The quality and number of fasteners according to structural designer specification
concrete structure with coach screws1. Wood is installed onto concrete structure, fastening to steel plates welded to fastening plates in the prestressed
Fastening of load-bearing sheet to prestressed concrete structures
woodnon continuous
Attention:
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 17IN00A401718.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4017
Profile T45
Profile T60
Profile T55
1
1
1
2
2
2
* - flange and fastener number according to structural design
2. Fastener on sidelaps c\c max 500 mm
Load-bearing sheet - Insulated roofInstallation - Sidelap
1. Ruukki load-bearing sheet
Standard sidelap of load-bearing sheets - Insulated roof
colour
colour
colour
Profile T70 - 5-flanges1
2colour
Profile T70 - 4-flanges1
2colour
01
Rautaruukki Corporation.CCopyright
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
IN 18IN00A401818.10.2005
Ruukki
1:5
07.04.2011
.
IN00A4018
Standard sidelap of load bearing sheets - Insulated roof
Profile T85
Profil 153 A
Profile T130
2
2
1
2
1
1
Load bearing sheet - Insulated roofInstallation - Sidelap
colour
colour
colour
01
Rautaruukki Corporation.CCopyright
* - flange and fastener number according to structural design
2. Fastener on sidelaps c\c max 500 mm1. Ruukki load-bearing sheet
IN 19 0215.12.2000
Ruukki
:
04.08.2021
..
IN00A4019
6
7
54
1
3
2
-
+
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailFlat roofs - 1
.
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Flat roofs with inclinations 1:20-1:40
FIRE PROTECTION, WHEN NECESSARYLOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING
VAPOUR BARRIER, NET REINFORCED ALUMINIUM COATED PLASTIC,THERMAL INSULATIONTHERMAL INSULATION, SUITED FOR WATER INSULATION'S BASEWATER INSULATION
STRUCTURAL LAYERS
APPLICATIONS
OVERLAPPING 200 mm + TAPING
67
5
43
12
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
For acoustic purposes a load-bearing structure with acoustic perforation can bechosen. In which case it has to be made sure with a separate dust suppressioncloth, that the load-bearing sheet's upper damping insulation is dustless.
Structure's fire resistance time can be influenced with underneath covering.Structural designer determines the covering according to the required fire resistancetime.
INSTRUCTIONS
THERMAL INSULATION, LOAD BEARING INSULATION,THAT SUPPORTS VAPOUR BARRIER
IN 20 0215.12.2000
Ruukki
:
..
IN00A4020
231
456
04.08.2021
7
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailFlat roofs - 2
.
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
STRUCTURAL LAYERS
4
21
3
PROTECTIVE GRAVEL, d= 8...20, >35 kg/m2WATER INSULATIONTHERMAL INSULATIONTHERMAL INSULATION, SLOTTEDVAPOUR BARRIER, NET REINFORCED ALUMINIUM COATED PLASTIC,OVERLAPPING 200 mm + TAPING
LOAD-BEARING PROFILED SHEET WITH ACOUSTIC PERFORATIONACCORDING TO CONSTRUCTION DRAWING
Flat roofs with inclinations 1:20-1:40APPLICATIONS
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
For acoustic purposes a load-bearing structure with acoustic perforation can bechosen. In which case it has to be made sure with a separate dust suppressioncloth, that the load-bearing sheet's upper damping insulation is dustless.
Structure's fire resistance time can be influenced with underneath covering.Structural designer determines the covering according to the required fire resistancetime.
INSTRUCTIONS
5
THERMAL INSULATION, LOAD BEARING INSULATION,THAT SUPPORTS VAPOUR BARRIER
6
7
IN 21 0215.12.2000
Ruukki
:
..
IN00A4021
23
1
4
6
7
04.08.2021
5
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailDouble pitched roofs or similar - 1
.
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
APPLICATIONS
STRUCTURAL LAYERS
4
21
3
WATER INSULATIONTHERMAL INSULATIONTHERMAL INSULATION, SLOTTEDVAPOUR BARRIER, NET REINFORCED ALUMINIUM COATED PLASTIC,OVERLAPPING 200 mm + TAPING
FIRE PROTECTION, WHEN NECESSARY
Double pitched roofs or similar with inclinations >1:40
LOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
For acoustic purposes a load-bearing structure with acoustic perforation can bechosen. In which case it has to be made sure with a separate dust suppressioncloth, that the load-bearing sheet's upper damping insulation is dustless.
Structure's fire resistance time can be influenced with underneath covering.Structural designer determines the covering according to the required fire resistancetime.
INSTRUCTIONS
5 THERMAL INSULATION, LOAD BEARING INSULATION,THAT SUPPORTS VAPOUR BARRIER
67
IN 22 0215.12.2000
Ruukki
:
..
IN00A4022
04.08.2021Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailDouble pitched roofs or similar - 2
.
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
STRUCTURAL LAYERS
4
21
3
6
WATER INSULATIONTHERMAL INSULATIONTHERMAL INSULATION, SLOTTEDVAPOUR BARRIER, NET REINFORCED ALUMINIUM COATED PLASTIC,OVERLAPPING 200 mm + TAPING
LOAD-BEARING SHEET WITH ACOUSTIC PERFORATION
SECONDARY STRUCTURE ACCORDING TO CONSTRUCTION DRAWING7ACCORDING TO CONSTRUCTION DRAWING
APPLICATIONS Shortening reverberation time
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
For acoustic purposes a load-bearing structure with acoustic perforation can bechosen. In which case it has to be made sure with a separate dust suppressioncloth, that the load-bearing sheet's upper damping insulation is dustless.
Structure's fire resistance time can be influenced with underneath covering.Structural designer determines the covering according to the required fire resistancetime.
INSTRUCTIONS
5 THERMAL INSULATION, LOAD BEARING INSULATION,THAT SUPPORTS VAPOUR BARRIER
Double pitched roofs or similar with inclinations >1:40
23
1
4
65
7
IN 23 0215.12.2000
Ruukki
:
..
IN00A4023
23
1
4
65
04.08.2021Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailDouble pitched roofs or similar - 3
.
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
STRUCTURAL LAYERS
4
21
3
6
WATER INSULATIONTHERMAL INSULATIONTHERMAL INSULATION, SLOTTEDVAPOUR BARRIER, NET REINFORCED ALUMINIUM COATED PLASTIC,OVERLAPPING 200 mm + TAPING
LOAD-BEARING PROFILED SHEET WITH ACOUSTIC PERFORATION
SECONDARY STRUCTURE ACCORDING TO CONSTRUCTION DRAWING7ACCORDING TO CONSTRUCTION DRAWING
APPLICATIONS Shortening reverberation time
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
For acoustic purposes a load-bearing structure with acoustic perforation can bechosen. In which case it has to be made sure with a separate dust suppressioncloth, that the load-bearing sheet's upper damping insulation is dustless.
Structure's fire resistance time can be influenced with underneath covering.Structural designer determines the covering according to the required fire resistancetime.
INSTRUCTIONS
5 THERMAL INSULATION, LOAD BEARING INSULATION,THAT SUPPORTS VAPOUR BARRIER
Double pitched roofs or similar with inclinations >1:40
7
IN 24 0215.12.2000
Ruukki
:
..
IN00A4024
3
6
4
12
04.08.2021Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailDouble pitched roofs or similar - 4
.
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
STRUCTURAL LAYERS
4
21
3
WATER INSULATIONTHERMAL INSULATIONTHERMAL INSULATION, SLOTTEDVAPOUR BARRIER, NET REINFORCED ALUMINIUM COATED PLASTIC,OVERLAPPING 200 mm + TAPING
6 LOAD-BEARING PROFILED SHEET WITH ACOUSTIC PERFORATIONACCORDING TO CONSTRUCTION DRAWING, WOOL BACKFILL IN FLANGES
Shortening reverberation timeAPPLICATIONS
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
For the acoustic purposes, a load-bearing structure with acoustic perforation can bechosen. Also, acoustic infill is recommended to confirm the required absorptionclass (A-E). A separate dust suppression cloth is recommended to prevent anyinsulation wool dust from entering the inside room.
Structure's fire resistance time can be influenced with underneath covering.Structural designer determines the covering according to the required fire resistancetime.
INSTRUCTIONS
Double pitched roofs or similar with inclinations >1:40
5
THERMAL INSULATION, LOAD BEARING INSULATION,THAT SUPPORTS VAPOUR BARRIER
5
78
7 DUST SUPPRESSION CLOTH8 PERFORATED LOW PROFILE
IN 25 0215.12.2000
Ruukki
:
..
IN00A4025
23
1
456
8
04.08.2021Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailDouble pitched roofs or similar - 5
.
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
INSTRUCTIONS
STRUCTURAL LAYERS
4
2
1
3
5
WATER INSULATION, PROFILED SHEET,
VENTILATING STEEL BATTENTHERMAL INSULATIONTHERMAL INSULATIONVAPOUR BARRIER, NET REINFORCED ALUMINIUM COATED PLASTIC,OVERLAPPING 200 mm + TAPING
(ACOUSTIC PERFORATION, WOOL BACKFILL IN FLANGES, WHEN NECESSARY)LOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING7
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arranged e.g.with inward relief valves according to construction drawing. Water insulation class incompliance with construction drawing.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
For acoustic purposes a load-bearing structure with acoustic perforation can bechosen. In which case it has to be made sure with a separate dust suppressioncloth, that the load-bearing sheet's upper damping insulation is dustless. The fireprotection wool also acts like acoustic insulation.
Structure's fire resistance time can be influenced with underneath covering. Also theacoustic infill increases the fire resistance time. Structural designer determines thecovering according to the required fire resistance time.
Double pitched roofs or similar with inclinations >1:10APPLICATIONS
ANTI-CONDENSATION COAT ON LOWER SURFACE
THERMAL INSULATION, LOAD BEARING INSULATION,THAT SUPPORTS VAPOUR BARRIER
6
7
8 FIRE PROTECTION, WHEN NECESSARY
IN 26 0115.12.2000
Ruukki
:
..
IN00A4026
123
4
5
21.7.2011.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Load-bearing sheetStructural detailWarehouse roofs - 1
4
21
3
5
WATER INSULATIONWEATHERING PLYWOODLOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION
PURLIN STRUCTURE ACCORDING TO CONSTRUCTION DRAWINGLOAD-BEARING STEEL FRAME ACCORDING TO CONSTRUCTION DRAWING
DRAWING, ANTI-CONDENSATION COATING ON THE SHEET'S
STRUCTURAL LAYERS
INSTRUCTIONS
Warehouse roofs, inclinations >1:40
Counter inclinations >1:60
APPLICATIONS
Water insulation class in compliance with construction drawing
LOWER SURFACE, WHEN NECESSARY
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
IN 27 0115.12.2000
Ruukki
:
..
IN00A4027
123
4
21.7.2011.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detailWarehouse roofs - 2
21
3
4
WATER INSULATIONWEATHERING PLYWOODLOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION
LOAD-BEARING STEEL FRAME ACCORDING TO CONSTRUCTION DRAWING
DRAWING, ANTI-CONDENSATION COATING ON THE SHEET'S
STRUCTURAL LAYERS
INSTRUCTIONS
Warehouse roofs, inclinations >1:40
Counter inclinations >1:60
APPLICATIONS
Water insulation class in compliance with construction drawing
LOWER SURFACE, WHEN NECESSARY
In 28 0115.12.2000
Ruukki
:
..
IN00A4028
1
2
3
4
5
21.7.2011.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detailWarehouse roofs - 3
4
21
3
5
WATER INSULATIONTHERMAL INSULATION, SUITED FOR WATER INSULATION'S BASELOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING,
PURLIN STRUCTURE ACCORDING TO CONSTRUCTION DRAWINGLOAD-BEARING STEEL STRUCTURE ACCORDING TO CONSTRUCTION DRAWING
ANTI-CONDENSATION COATING ON THE SHEET'S LOWER SURFACE,
STRUCTURAL LAYERS
INSTRUCTIONS
Warehouse roofs, inclinations >1:40APPLICATIONS
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
WHEN NECESSARY
IN 29 0115.12.2000
Ruukki
:
..
IN00A4029
1
2
3
4
21.7.2011.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detailWarehouse roofs - 4
21
3
4
WATER INSULATIONTHERMAL INSULATION, SUITED FOR WATER INSULATION'S BASELOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING,
LOAD-BEARING STEEL STRUCTURE ACCORDING TO CONSTRUCTION DRAWING
ANTI-CONDENSATION COATING ON THE SHEET'S LOWER SURFACE,
STRUCTURAL LAYERS
INSTRUCTIONS
Warehouse roofs, inclinations >1:40APPLICATIONS
Water insulation is fastened mechanically through thermal insulation to supportstructure. If the used water insulation requires ventilation ducts in the thermalinsulation, it has to be made sure that they are continous. Replacement air isprovided to the ventilation ducts at eaves and exthaust ventilation is arrangede.g. with inward relief valves according to construction drawing. Water insulationclass in compliance with construction drawing. Counter inclinations ≥ 1:60.
Thickness of the thermal insulation layer is determined by the used insulationmaterial so that the structure conforms to required U-value.
WHEN NECESSARY
IN30 0115.12.2000
Ruukki
:
..
IN00A4030
1
2
3
21.7.2011.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detailCanopy and warehouse roofs
1 WATER INSULATION, LOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING, ANTI-CONDENSATION
2 PURLIN STRUCTURE ACCORDING TO CONSTRUCTION DRAWING
STRUCTURAL LAYERS
Canopy and warehouse roofs inclinations >1:10
3 LOAD-BEARING STRUCTURE ACCORDING TO CONSTRUCTION DRAWING
APPLICATIONS
COATING ON THE SHEET'S LOWER SURFACE, WHEN NECESSARY
IN 31 0215.12.2000
Ruukki
:
..
IN00A4031
04.08.2021
Secondary steel supports for the SPApanels according to structural designer
Reverse dip is made of Leca-
Note! Profiled sheet installationis started up from eaves
Profiled sheet supportsacc. to structural designer
Insulation support flashingat SPA support, from above
1:10to structures below for L~400mmWaterproofing in not fastened
gravel, Siporex chips or wool-sheets cut to form
+-
SEE ALSO SANDWICH PANEL SPA DETAIL: SPA06-1E-FI
1. RUUKKI SANDWICH PANEL, HORIZONTAL MOUNTING
2. EAVE FLASHING
3. PROTECTIVE FLASHING
4. STORM FLASHING
5. INSULATION SUPPORT FLASHING, T=0.6MM
6. FLAT STEEL FOR VAPOUR BARRIER FIXING, T=0.6MM
7. FASTENER
8. VAPOUR BARRIER
9. LOAD-BEARING PROFILED SHEET
1
2
7
3
7
4
5
6
8
Vapour barriermovable joint
315
100
5
6
8
9
7
10. THERMAL INSULATION
11. WATER INSULATION
11
10
.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detail - 1
Horizontal supportstudwork
Vertical supportstudwork
IN 32 0215.12.2000
Ruukki
:
..
IN00A4032
3. INSULATION SUPPORT FLASHING, T=0.6MM
4. FLAT STEEL FOR VAPOUR BARRIER FIXING, T=0.6MM
5. STORM FLASHING
6. WOOD
7. FASTENER
04.08.2021
Wooden wedge Plywood
designed according to projectGutters and it's brackets
+-
Profiled sheet supportsacc. to structural designer
SEE ALSO SANDWICH PANEL SPA DETAIL: SPA06-11E-FI
Vapour barriermovable joint
315
100
3
4
8
1
2
3
5
6
7
7
8
9
7
C-steel profile
7
10. THERMAL INSULATION
11. WATER INSULATION
11
10
2. EAVE FLASHING
1. RUUKKI SANDWICH PANEL, HORIZONTAL MOUNTING 8. VAPOUR BARRIER
9. LOAD-BEARING PROFILED SHEET
.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detail - 2
IN 33 0215.12.2000
Ruukki
:
..
IN00A4033
7. VENTILATING STEEL BATTEN
6. FASTENER
5. STORM FLASHING
4. FLAT STEEL FOR VAPOUR BARRIER FIXING, T=0.6MM
3. INSULATION SUPPORT FLASHING, T=0.6MM
2. EAVE FLASHING
1. RUUKKI SANDWICH PANEL, HORIZONTAL MOUNTING
04.08.2021
315100
Vapour barriermovable joint
designed according to projectGutters and it's brackets
treatment recommendedProfiled sheet, anti-condence
C-steel profile
+-Profiled sheet supportsacc. to structural designer
SEE ALSO SANDWICH PANEL SPA DETAIL: SPA06-9E-FI
8. VAPOUR BARRIER
9. LOAD-BEARING PROFILED SHEET
96
1
23
4
3
8
5
6
6
67
6
10
10. THERMAL INSULATION
11. WATER INSULATION, PROFILED SHEET
11
.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detail - 3
IN 34 0215.12.2000
Ruukki
:
..
IN00A4034
4. FLAT STEEL FOR VAPOUR BARRIER FIXING, T=0.6MM5. EAVE FLASHING
7. FASTENER6. VAPOUR BARRIER
2. VENTILATING STEEL BATTEN3. INSULATION SUPPORT FLASHING, T=0.6MM
1. RUUKKI SANDWICH PANEL, HORIZONTAL MOUNTING
04.08.2021
is dimensionedaccording to project
Insulation thickness150
100
Vapour barriermovable joint
treatment recommendedProfiled sheet, anti-condence
SEE ALSO SANDWICH PANEL SPA DETAIL: SPA06-10E-FI
8. LOAD-BEARING PROFILED SHEET
+- 8
1
7
27
7
7
3
3
4
5
6
7
9. THERMAL INSULATION
10. WATER INSULATION, PROFILED SHEET
109
.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detail - 4
IN 35 0215.12.2000
Ruukki
:
..
rIN00A4035
04.08.2021
Ventilation groovesPlywood
Wooden wedge
SEE ALSO SANDWICH PANEL SPA DETAIL: SPA06-12E-FI
4. FLAT STEEL FOR VAPOUR BARRIER FIXING, T=0.6MM5. FASTENER
7. LOAD-BEARING PROFILED SHEET6. VAPOUR BARRIER
2. EAVE FLASHING3. INSULATION SUPPORT FLASHING, T=0.6MM
1. RUUKKI SANDWICH PANEL, HORIZONTAL MOUNTING
+
1
-
5
150100
Vapour barriermovable joint
3
4
is dimensionedaccording to project
Insulation thickness52
6
7
5 5
8. THERMAL INSULATION
9. WATER INSULATION, PROFILED SHEET
89
3
.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Load-bearing sheetStructural detail - 5
Load-bearing sheetStructural detailIntermediate floor
IN 36 01.15.12.2000
Ruukki
:
..
IN00A4036
12
4
3
21.7.2011
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
SURFACE MATERIAL ACCORDING TO DESIGNER SPECIFICATIONTOPPINGREINFORCED CONCRETE SLAB
LOAD-BEARING PROFILED SHEET MOULD ACCORDING TO CONSTRUCTION DRAWING
STRUCTURAL LAYERS123
4
APPLICATIONSConcrete floors
ACCORDING TO CONSTRUCTION DRAWING
REINFORCEMENTS ACCORDING TO CONSTRUCTION DRAWING
Load-bearing sheetStructural detailLight-weight intermediate floor
IN 37 01.15.12.2000
Ruukki
:
..
IN00A4037
3
12
4
21.7.2011
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
21
CLADDING ACCORDING TO DESIGNFIRE PROTECTION, WHEN NECESSARYLOAD-BEARING PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING
STRUCTURAL LAYERS
APPLICATIONS
BUILDING BOARD(S), FASTENING ACCORDING TO CONSTRUCTION DRAWING
43
Lightly stressed intermediate floors
SURFACE MATERIAL ACCORDING TO DESIGNER SPECIFICATION
Load-bearing sheetStructural detailUninsulated walls - 1
IN 38 01.15.12.2000
Ruukki
:
..
IN00A4038
12
21.7.2011
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
APPLICATIONS
STRUCTURAL LAYERS
21 PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING
PURLIN STRUCTURE ACCORDING TO CONSTRUCTION DRAWING
Uninsulated walls
IN 39 01.15.12.2000
Ruukki
:
..
IN00A4039
21.7.2011
1 2
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
APPLICATIONS
STRUCTURAL LAYERS
21 PROFILED SHEET ACCORDING TO CONSTRUCTION DRAWING
STEEL STRUCTURE ACCORDING TO CONSTRUCTION DRAWING
Uninsulated walls
Load-bearing sheetStructural detailUninsulated walls - 2
Load-bearing sheetStructural detailFastening of acoustic insulation wool - 1
IN 40 02.15.12.2000
Ruukki
:
..
IN00A4040
ACOUSTIC INSULATION WOOL IS GLUED TO PROFILED SHEET E.G. WITH ACOUSTIC GLUE.
IN OPEN JOINT INSTALLATION APPROX. 10 mm GAP IS LEFT BETWEEN SHEETS.
FASTENING OF BARREL RIDGE TO PROFILED SHEET
E.G. WITH HIDDEN RIVETS
04.08.2021
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
FASTENING OF ACOUSTIC INSULATION WOOLADHESIVE INSTALLATION
FASTENING OF ACOUSTIC INSULATION WOOLBARREL RIDGE INSTALLATION
Load-bearing sheetStructural detailFastening of acoustic insulation wool - 2
IN 41 02.15.12.2000
Ruukki
:
..
IN00A4041
04.08.2021
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
FASTENING OF ACOUSTIC INSULATION WOOLT-FLASNING / SUSPENDED CEILING
IF VAPOUR BARRIER IS USED DIRECTLY ON TOP OF PROFILED SHEET,
BRACKETS ARE FASTENED FROM FLANGES' BOTTOM OR SIDE.
BRACKET SHALL NOT BE FASTENED TO FLANGE'S CROWN.
Load-bearing sheetStructural detailOpening
IN 42 01.15.12.2000
Ruukki
:
..
IN00A4042
STEEL SUPPORTS AND FASTENING SCREWS ACCORDING TO
A FRAME AROUND THE OPENING IS MADE OF C- AND HAT PURLINS
CONSTRUCTION DESIGNER SPECIFICATION.
WHICH SUPPORTS HOLE'S EDGES.
21.7.2011
SMOKE RELEASE HATCH
HAT PURLIN
VAPOURBARRIER
C-PURLIN
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
SUPPORTING FROM ABOVE
PL10-150*L k 2000
k 2000
L
L ACCORDING TO PROFILE
Load-bearing sheetStructural detailSupporting - 1
IN 43 01.15.12.2000
Ruukki
:
..
IN00A4043
21.7.2011
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing
LOAD-BEARING SHEET AND STRUCTURE TO BE SUPPORTED.
DISTANCE BETWEEN SUPPORTS HAS TO BE CHECKED ACCORDING TO
SUPPORTS ARE TO BE INSTALLED BEFORE INSULATION AND VAPOUR BARRIER.
THREAD BAR ACCORDING TOSUPPORT SYSTEM
PL10-B*250 k 2000
THREAD BAR ACCORDING TOSUPPORT SYSTEM
SUPPORTING FROM FLANGE
k 2000
B ACCORDING TO PROFILE
Load-bearing sheetStructural detailSupporting - 2
IN 44 01.15.12.2000
Ruukki
:
..
IN00A4044
LOAD-BEARING SHEET AND STRUCTURE TO BE SUPPORTED.
DISTANCE BETWEEN SUPPORTS HAS TO BE CHECKED ACCORDING TO
SUPPORTS ARE TO BE INSTALLED BEFORE INSULATION AND VAPOUR BARRIER.
21.7.2011
Copyright © Rautaruukki Corporation. Allowed only for designs with Ruukki's products.
Date
Scale
Drawn by
Rev.Drw. nr.
File nr.
Rev. date
Building
Rev.
Work nr.
Contents of drawing