pickens street - scpurchasing.sc.edu/solicitations/h27-6094-c drawings.pdfsheet details d1 pf no....
TRANSCRIPT
-
2 KEY PLAN
UNIVERSITY OF SOUTH CAROLINAHUMANITIES OFFICE
AND CLASSROOM BUILDINGSREROOFING CONSTRUCTION PROJECT
DRAWING INDEX
SHEET CONTENTS
K1 TITLE SHEET, SITE VICINITY MAP, KEY PLAN & DRAWING INDEXR1 ROOF PLAN - OFFICE BUILDINGR2 ROOF PLAN - CLASSROOM BUILDINGD1 DETAILSD2 DETAILSD3 DETAILS
1 SITE VICINITY MAPSHEET
Key
Pla
n
K1
PF No. 11012.003.004
DATE: 4-26-12
SCALE: NTS
DRAWN BY: WMM
CHECKED BY: WBS
NORTH
RA1
RA2RA3 RA3
PICKENS STREET
CLASSROOM BUILDING
OFFICEBUILDING
-
NO
RTH
AOWV
AOWV
AOWV
AOWV
RDRDRD RD
AOWV
FDC
SV
PPPP
PP
PP
PP
PP
HVACHVAC
GV
PP PP
AOWVAOWV
PPPP PP
PP PPPP
HVS
HVS
HVS
PP
PP
APP
PP
PP
SV
PP
PP
PP
PP
PP
PP
CURB MOUNTED CONDUITPENETRATION HOUSING
RA1
= ROOF AREA DESIGNATIONRA #
= ROOF DRAIN & SUMP
= GRAVITY VENTILATOR
RD
= SANITARY VENTSVAP
P
= ABANDONED PIPE PENETRATION
HVS
= HOT VENT STACK
= ROOF HATCH
= TAPERED INSULATION
= CONCRETE CONDUIT SUPPORT
= LIGHTNING PROTECTION
= PIPE PENETRATIONPPAO
WV
= ABANDON ONE WAY VENT
FDC
= FIRE DEPARTMENT CONNECTION
GV
HVAC = HVAC UNIT
= WALK PAD
3D4
3D3
1D4
TYP.
2D3
TYP.
TYP.
2D4 4
D4TYP.
TYP.
3D4
3D4
3D4
3D2
4D2
TYP.
4D4
LEGEND
1 ROOF PLAN - OFFICE BUILDINGNote: New 3" Base Insulation with 1/4":12" Taper
SHEET
Roo
f Pla
n
R1
PF No. 11012.003.004
DATE: 4-26-12
SCALE: NTS
DRAWN BY: WMM
CHECKED BY: WBS
2D2
3D3
ON WALK PAD
LPS AERIAL @ 20' OC (TYP)
3D3
TYP.
3D3
TYP.
= SLOPE IN INSULATION
SIM.
3D3
TYP.
= AREA IN CONTRACT
SASA
SA
SASA
SA
SASASASASA
SASASASASA
= SAFETY ANCHORSA
5D3 TYP.
-
NORTH
= ROOF AREA DESIGNATIONRA #
= ROOF DRAIN
= JUNCTION BOX
RD
= SANITARY VENTSV
= WALL MOUNTED ANTENNA
HVS
= HOT VENT STACK
= ROOF HATCH= TAPERED INSULATION
= BALLASTED P.A. SYSTEM SPEAKERS
AP
= ABANDON WALL MOUNTED PIPE
= PIPE PENETRATIONPP
AOWV
= ABANDON ONE WAY VENT
FDC
= FIRE DEPARTMENT CONNECTION
RD
AOWV
SV
HVS
HVS
HVS
RD
RD
RD
JB JB
JB
AOWV
RD
SV
RA2
RA3
RA3FDCPP
PP
PP
PP
RD
JBAP
RDRD
WMA
WMA
JB
1 ROOF PLAN - CLASSROOM BUILDING
SAT
SAT = SATELLITE TV DISH
4D1
1D3
1D1
1D1
4D1
1D1
4D1
4D1
1D2
1D1
2D1
2D2
TYP.
LEGEND
TYP.
3D3
TYP.
SHEET
Roo
f Pla
n
R2
PF No. 11012.003.004
DATE: 4-26-12
SCALE: NTS
DRAWN BY: WMM
CHECKED BY: WBS
WALL MOUNTED CONDUIT WALL MOUNTED CONDUIT
WALL
MO
UNTE
D C
OND
UIT
CONDUIT
CONDUIT
3D3
3D1
LOW HIGH
3D1
1D3
LOWHIGH
= WALK PAD
= SLOPE IN INSULATION
= AREA IN CONTRACT
= SLOPE IN ROOF DECK
SA SA SA SA SA SASASA
SA SA SA SA SA SASASA
SA
SASA
SA
SASA
SA
SA
SASA
SA SA
SASA
= NEW SAFETY ANCHORSA
Note: RA 2 - No Base Insulation w/ 1/8":12 Tapered Above LWC Deck.RA 3 1-1/2" Base Insulation w/ No Tapered Insulation.
5D3
TYP.
-
SHEET
Det
ails
D1
PF No. 11012.003.004
DATE: 4-26-12
SCALE: NTS
DRAWN BY: WMM
CHECKED BY: WBS
2 TYPICAL SANITARY VENT DETAIL 1 TYPICAL ROOF DRAIN DETAIL
4 PARAPET DETAIL
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW STRIPPING PLY
EXISTING SANITARY VENT
NEW LIQUID APPLIED FLASHING
4" MIN.4" MIN. 8" M
IN.
NEW BITUMINOUS SEALANT
NEW BASE PLY
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW BASE PLY
NEW BASE FLASHINGNEW CANT
NEW METAL COPING CAP
NEW METAL LOCKING CLEAT
NEW 20 MIL PVC FLASHING
NEW WOOD BLOCKING WITH 1" x 1" NOTCH ON BOTTOM @ 24" O.C.
4" x 38
NEW 48" LONG WOOD BLOCKINGRAISED 1" OFF DECK WITH 2" SPACE
BETWEEN BLOCKING PIECES
NEW PLYWOOD SHEATHINGRAISED 12" OFF DECK NEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW BASE PLY
NEW BASE FLASHINGNEW CANT
NEW METAL COPING CAP
NEW METAL LOCKING CLEAT
NEW 20 MIL PVC FLASHING
NEW WOOD BLOCKING WITH 1" x 1" NOTCH ON BOTTOM @ 24" O.C.
4" x 38
NEW 48" LONG WOOD BLOCKINGRAISED 1" OFF DECK WITH 2" SPACE
BETWEEN BLOCKING PIECES
NEW PLYWOOD SHEATHINGRAISED 12" OFF DECK
3 PARAPET DETAIL
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW STRIPPING PLY
NEW TAPERED EDGE STRIPNEW LEAD FLASHING
NEW BASE PLY
NEW ROOF DRAIN
EXISTING STRUCTURE
EXISTING STRUCTURE
EXISTING STRUCTURE EXISTING STRUCTURE
-
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW STRIPPING PLY
NEW BASE PLY
NEW FOAM GLASS INSULATION
NEW FLANGED METAL SLEEVENEW VENT BONNET
EXISTING VENT BONNETEXISTING HOT VENT STACK
1 TYPICAL HOT VENT STACK DETAIL
SHEET
Det
ails
D2
PF No. 11012.003.004
DATE: 4-26-12
SCALE: NTS
DRAWN BY: WMM
CHECKED BY: WBS
2 EXISTING ROOF HATCH DETAIL
NEW BASE FLASHINGNEW CANT
EXISTING ROOF HATCH FRAME
4 EXISTING HVAC PLATFORM CURB
EXISTING EQUIPMENT CURB
EXISTING EQUIPMENT COVER
3 TELEPHONE CONDUIT PENETRATION HOUSING CURB
3" MIN.
NEW WOOD BLOCKING
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW BASE PLYNEW CAP SHEET
NEW WOOD BLOCKING
NEW TAPERED EDGE STRIP
NEW LIQUID APPLIED FLASHING
EXISTING METAL HVAC PLATFORM
NEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY VAPOR BARRIER
NEW BASE PLYNEW CAP SHEET
EXISTING METAL FLASHING -GENTLY BEND EXISTING
METAL FLASHING TO INSTALL
NEW 5" x 38@ 24" O.C. MAX.
NEW STRIPPING PLY
NEW LIQUID APPLIED FLASHING
NEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY VAPOR BARRIER
NEW BASE PLYNEW CAP SHEET
EXISTING METAL FLASHING -GENTLY BEND EXISTING
METAL FLASHING TO INSTALL
EXISTING STRUCTURE
EXISTING STRUCTURE
EXISTING STRUCTURE EXISTING STRUCTURE
2A EXISTING ROOF HATCH DETAIL @ CONDUIT PENETRATION
NEW CANTNEW LIQUID APPLIED FLASHING
EXISTING ROOFHATCH FRAME
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW BASE PLYNEW CAP SHEET
NEW WOOD BLOCKING
NEW 5" x 38@ 24" O.C. MAX.
EXISTING STRUCTURE
EXISTING CONDUIT
USE THIS SECTION ON SIDE WHERE CONDUIT PENETRATES ROOF HATCH FRAME ONLY
EXISTING METAL FLASHING
NEW BITUMINOUS SEALANT
NEW BITUMINOUS SEALANT
EXISTING BLOCKING
NEW METAL FLASHING
EXISTING LIGHTWEIGHT FILLOR NEW BASE INSULATIONOVER NEW VAPOR BARRIER
NEW FILL INSULATION
NEW TAPERED INSULATION
NEW FILL INSULATIONNEW TAPERED INSULATION
EXISTING WOOD BLOCKING
EXISTING WOOD BLOCKING
-
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW BASE PLY
NEW LIQUID APPLIED FLASHING
SHEET
Det
ails
D3
PF No. 11012.003.004
DATE: 4-26-12
SCALE: NTS
DRAWN BY: WMM
CHECKED BY: WBS
1 TYPICAL DETAIL AT LOUVER 2 TYPICAL DETAIL AT CONCRETE CONDUIT STAND
NEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY VAPOR BARRIER
NEW CAP SHEETNEW BASE PLY
NEW WALK PAD UNDERCONCRETE CONDUIT STAND
EXISTING 13" x 36" CONCRETECONDUIT STAND
EXISTING LOUVER
3 TYPICAL PIPE PENETRATION DETAIL
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW STRIPPING PLY
EXISTING PIPE
NEW LIQUID APPLIED FLASHING
4" MIN.4" MIN.
8" M
IN.
NEW BITUMINOUS SEALANT
NEW BASE PLY
NEW BITUMINOUS SEALANT
NEW STRIPPING PLY
NEW METAL COUNTERFLASHINGNEW METAL RECEIVER
EXISTING STRUCTURE
EXISTING STRUCTURE
VARIE
S
NEW BACKER RODAND SEALANT
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW STRIPPING PLY
NEW BASE PLY
NEW BATT INSULATION
NEW 2" DIA. HOLENEW BITUMINOUS SEALANT
NEW WOOD BLOCKING
4 NEW ONE WAY VENT DETAIL
NEW ONE WAY VENT
USE THIS SECTION AT LOUVER WALL WHERE DOOR IS LOCATED
TYPICAL DETAIL AT LOUVER
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW BASE PLY
NEW LIQUID APPLIED FLASHINGNEW BITUMINOUS SEALANT
NEW STRIPPING PLY
EXISTING DOOR EXISTING METAL THRESHOLD
EXISTING STRUCTURE
4" MIN.(TYP.)
4" MIN.4" MIN. 8" M
IN.
5 SAFETY ANCHOR BASE DETAIL
NEW BASE INSULATIONNEW COVERBOARD
NEW 2 PLY MEMBRANEOVER BASE SHEET
NEW CAP SHEETNEW STRIPPING PLY
NEW SAFETY ANCHORASSEMBLY
NEW LIQUID APPLIED FLASHINGNEW BITUMINOUS SEALANT
NEW BASE PLY
NEW ANGLE IRON ASSEMBLY
2'-0" MIN.
NEW LIGHTWEIGHT FILLOR BASE INSULATION
OVER VAPOR BARRIER
EXISTING LIGHTWEIGHT FILLOR NEW BASE INSULATION
OVER NEW VAPOR BARRIER
EXISTING STRUCTURAL SLAB
EXISTING LIGHTWEIGHT FILLOR NEW BASE INSULATIONOVER NEW VAPOR BARRIER
NEW TAPERED INSULATION
-
SHEET
Det
ails
D4
PF No. 11012.003.004
DATE: 4-26-12
SCALE: NTS
DRAWN BY: WMM
CHECKED BY: WBS
NEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY VAPOR BARRIER
NEW CAP SHEETNEW BASE PLY
NEW BASE FLASHINGNEW CANT
NEW METAL COPING CAP
NEW METAL LOCKING CLEAT
NEW 20 MIL PVC FLASHING
NEW WOOD BLOCKING WITH 1" x 1" NOTCH ON BOTTOM @ 24" O.C.
4" x 38
NEW 48" LONG WOOD BLOCKINGRAISED 1" OFF DECK WITH 2" SPACE
BETWEEN BLOCKING PIECES
NEW PLYWOOD SHEATHINGRAISED 12" OFF DECK
3 PARAPET DETAIL
EXISTING STRUCTURE
1 TYPICAL ROOF DRAIN DETAIL 2 TYPICAL SANITARY VENT DETAIL
NEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY VAPOR BARRIER
NEW CAP SHEETNEW STRIPPING PLY
EXISTING SANITARY VENT
NEW LIQUID APPLIED FLASHING
4" MIN.4" MIN. 8" M
IN.
NEW BITUMINOUS SEALANT
NEW BASE PLY
EXISTING STRUCTURE
NEW TAPERED INSULATIONNEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY VAPOR BARRIER
NEW CAP SHEETNEW STRIPPING PLY
NEW TAPERED EDGE STRIPNEW LEAD FLASHING
NEW BASE PLY
NEW ROOF DRAIN
NEW TAPERED INSULATION
NEW BASE INSULATION
NEW COVERBOARD
NEW 2 PLY VAPOR BARRIER
NEW CAP SHEETNEW STRIPPING PLY
NEW BASE PLY
NEW FOAM GLASS INSULATION
NEW FLANGED METAL SLEEVENEW VENT BONNET
EXISTING VENT BONNETEXISTING HOT VENT STACK
4 TYPICAL HOT VENT STACK DETAIL
3" MIN.
NEW WOOD BLOCKING
EXISTING STRUCTURE
NEW TAPERED INSULATION
NEW FILL INSULATIONNEW TAPERED INSULATION
NEW FILL INSULATION
K1-signedR1-signedR2-signedD1-signedD2-signedD3-signedD4-signed