2 KEY PLAN UNIVERSITY OF SOUTH CAROLINA HUMANITIES OFFICE AND CLASSROOM BUILDINGS REROOFING CONSTRUCTION PROJECT DRAWING INDEX SHEET CONTENTS K1 TITLE SHEET, SITE VICINITY MAP, KEY PLAN & DRAWING INDEX R1 ROOF PLAN - OFFICE BUILDING R2 ROOF PLAN - CLASSROOM BUILDING D1 DETAILS D2 DETAILS D3 DETAILS 1 SITE VICINITY MAP SHEET Key Plan K1 PF No. 11012.003.004 DATE: 4-26-12 SCALE: NTS DRAWN BY: WMM CHECKED BY: WBS NORTH RA1 RA2 RA3 RA3 PICKENS STREET CLASSROOM BUILDING OFFICE BUILDING

Upload: others

Post on 02-Feb-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

  • 2 KEY PLAN

    UNIVERSITY OF SOUTH CAROLINAHUMANITIES OFFICE

    AND CLASSROOM BUILDINGSREROOFING CONSTRUCTION PROJECT

    DRAWING INDEX

    SHEET CONTENTS

    K1 TITLE SHEET, SITE VICINITY MAP, KEY PLAN & DRAWING INDEXR1 ROOF PLAN - OFFICE BUILDINGR2 ROOF PLAN - CLASSROOM BUILDINGD1 DETAILSD2 DETAILSD3 DETAILS

    1 SITE VICINITY MAPSHEET

    Key

    Pla

    n

    K1

    PF No. 11012.003.004

    DATE: 4-26-12

    SCALE: NTS

    DRAWN BY: WMM

    CHECKED BY: WBS

    NORTH

    RA1

    RA2RA3 RA3

    PICKENS STREET

    CLASSROOM BUILDING

    OFFICEBUILDING

  • NO

    RTH

    AOWV

    AOWV

    AOWV

    AOWV

    RDRDRD RD

    AOWV

    FDC

    SV

    PPPP

    PP

    PP

    PP

    PP

    HVACHVAC

    GV

    PP PP

    AOWVAOWV

    PPPP PP

    PP PPPP

    HVS

    HVS

    HVS

    PP

    PP

    APP

    PP

    PP

    SV

    PP

    PP

    PP

    PP

    PP

    PP

    CURB MOUNTED CONDUITPENETRATION HOUSING

    RA1

    = ROOF AREA DESIGNATIONRA #

    = ROOF DRAIN & SUMP

    = GRAVITY VENTILATOR

    RD

    = SANITARY VENTSVAP

    P

    = ABANDONED PIPE PENETRATION

    HVS

    = HOT VENT STACK

    = ROOF HATCH

    = TAPERED INSULATION

    = CONCRETE CONDUIT SUPPORT

    = LIGHTNING PROTECTION

    = PIPE PENETRATIONPPAO

    WV

    = ABANDON ONE WAY VENT

    FDC

    = FIRE DEPARTMENT CONNECTION

    GV

    HVAC = HVAC UNIT

    = WALK PAD

    3D4

    3D3

    1D4

    TYP.

    2D3

    TYP.

    TYP.

    2D4 4

    D4TYP.

    TYP.

    3D4

    3D4

    3D4

    3D2

    4D2

    TYP.

    4D4

    LEGEND

    1 ROOF PLAN - OFFICE BUILDINGNote: New 3" Base Insulation with 1/4":12" Taper

    SHEET

    Roo

    f Pla

    n

    R1

    PF No. 11012.003.004

    DATE: 4-26-12

    SCALE: NTS

    DRAWN BY: WMM

    CHECKED BY: WBS

    2D2

    3D3

    ON WALK PAD

    LPS AERIAL @ 20' OC (TYP)

    3D3

    TYP.

    3D3

    TYP.

    = SLOPE IN INSULATION

    SIM.

    3D3

    TYP.

    = AREA IN CONTRACT

    SASA

    SA

    SASA

    SA

    SASASASASA

    SASASASASA

    = SAFETY ANCHORSA

    5D3 TYP.

  • NORTH

    = ROOF AREA DESIGNATIONRA #

    = ROOF DRAIN

    = JUNCTION BOX

    RD

    = SANITARY VENTSV

    = WALL MOUNTED ANTENNA

    HVS

    = HOT VENT STACK

    = ROOF HATCH= TAPERED INSULATION

    = BALLASTED P.A. SYSTEM SPEAKERS

    AP

    = ABANDON WALL MOUNTED PIPE

    = PIPE PENETRATIONPP

    AOWV

    = ABANDON ONE WAY VENT

    FDC

    = FIRE DEPARTMENT CONNECTION

    RD

    AOWV

    SV

    HVS

    HVS

    HVS

    RD

    RD

    RD

    JB JB

    JB

    AOWV

    RD

    SV

    RA2

    RA3

    RA3FDCPP

    PP

    PP

    PP

    RD

    JBAP

    RDRD

    WMA

    WMA

    JB

    1 ROOF PLAN - CLASSROOM BUILDING

    SAT

    SAT = SATELLITE TV DISH

    4D1

    1D3

    1D1

    1D1

    4D1

    1D1

    4D1

    4D1

    1D2

    1D1

    2D1

    2D2

    TYP.

    LEGEND

    TYP.

    3D3

    TYP.

    SHEET

    Roo

    f Pla

    n

    R2

    PF No. 11012.003.004

    DATE: 4-26-12

    SCALE: NTS

    DRAWN BY: WMM

    CHECKED BY: WBS

    WALL MOUNTED CONDUIT WALL MOUNTED CONDUIT

    WALL

    MO

    UNTE

    D C

    OND

    UIT

    CONDUIT

    CONDUIT

    3D3

    3D1

    LOW HIGH

    3D1

    1D3

    LOWHIGH

    = WALK PAD

    = SLOPE IN INSULATION

    = AREA IN CONTRACT

    = SLOPE IN ROOF DECK

    SA SA SA SA SA SASASA

    SA SA SA SA SA SASASA

    SA

    SASA

    SA

    SASA

    SA

    SA

    SASA

    SA SA

    SASA

    = NEW SAFETY ANCHORSA

    Note: RA 2 - No Base Insulation w/ 1/8":12 Tapered Above LWC Deck.RA 3 1-1/2" Base Insulation w/ No Tapered Insulation.

    5D3

    TYP.

  • SHEET

    Det

    ails

    D1

    PF No. 11012.003.004

    DATE: 4-26-12

    SCALE: NTS

    DRAWN BY: WMM

    CHECKED BY: WBS

    2 TYPICAL SANITARY VENT DETAIL 1 TYPICAL ROOF DRAIN DETAIL

    4 PARAPET DETAIL

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW STRIPPING PLY

    EXISTING SANITARY VENT

    NEW LIQUID APPLIED FLASHING

    4" MIN.4" MIN. 8" M

    IN.

    NEW BITUMINOUS SEALANT

    NEW BASE PLY

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW BASE PLY

    NEW BASE FLASHINGNEW CANT

    NEW METAL COPING CAP

    NEW METAL LOCKING CLEAT

    NEW 20 MIL PVC FLASHING

    NEW WOOD BLOCKING WITH 1" x 1" NOTCH ON BOTTOM @ 24" O.C.

    4" x 38

    NEW 48" LONG WOOD BLOCKINGRAISED 1" OFF DECK WITH 2" SPACE

    BETWEEN BLOCKING PIECES

    NEW PLYWOOD SHEATHINGRAISED 12" OFF DECK NEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW BASE PLY

    NEW BASE FLASHINGNEW CANT

    NEW METAL COPING CAP

    NEW METAL LOCKING CLEAT

    NEW 20 MIL PVC FLASHING

    NEW WOOD BLOCKING WITH 1" x 1" NOTCH ON BOTTOM @ 24" O.C.

    4" x 38

    NEW 48" LONG WOOD BLOCKINGRAISED 1" OFF DECK WITH 2" SPACE

    BETWEEN BLOCKING PIECES

    NEW PLYWOOD SHEATHINGRAISED 12" OFF DECK

    3 PARAPET DETAIL

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW STRIPPING PLY

    NEW TAPERED EDGE STRIPNEW LEAD FLASHING

    NEW BASE PLY

    NEW ROOF DRAIN

    EXISTING STRUCTURE

    EXISTING STRUCTURE

    EXISTING STRUCTURE EXISTING STRUCTURE

  • NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW STRIPPING PLY

    NEW BASE PLY

    NEW FOAM GLASS INSULATION

    NEW FLANGED METAL SLEEVENEW VENT BONNET

    EXISTING VENT BONNETEXISTING HOT VENT STACK

    1 TYPICAL HOT VENT STACK DETAIL

    SHEET

    Det

    ails

    D2

    PF No. 11012.003.004

    DATE: 4-26-12

    SCALE: NTS

    DRAWN BY: WMM

    CHECKED BY: WBS

    2 EXISTING ROOF HATCH DETAIL

    NEW BASE FLASHINGNEW CANT

    EXISTING ROOF HATCH FRAME

    4 EXISTING HVAC PLATFORM CURB

    EXISTING EQUIPMENT CURB

    EXISTING EQUIPMENT COVER

    3 TELEPHONE CONDUIT PENETRATION HOUSING CURB

    3" MIN.

    NEW WOOD BLOCKING

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW BASE PLYNEW CAP SHEET

    NEW WOOD BLOCKING

    NEW TAPERED EDGE STRIP

    NEW LIQUID APPLIED FLASHING

    EXISTING METAL HVAC PLATFORM

    NEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY VAPOR BARRIER

    NEW BASE PLYNEW CAP SHEET

    EXISTING METAL FLASHING -GENTLY BEND EXISTING

    METAL FLASHING TO INSTALL

    NEW 5" x 38@ 24" O.C. MAX.

    NEW STRIPPING PLY

    NEW LIQUID APPLIED FLASHING

    NEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY VAPOR BARRIER

    NEW BASE PLYNEW CAP SHEET

    EXISTING METAL FLASHING -GENTLY BEND EXISTING

    METAL FLASHING TO INSTALL

    EXISTING STRUCTURE

    EXISTING STRUCTURE

    EXISTING STRUCTURE EXISTING STRUCTURE

    2A EXISTING ROOF HATCH DETAIL @ CONDUIT PENETRATION

    NEW CANTNEW LIQUID APPLIED FLASHING

    EXISTING ROOFHATCH FRAME

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW BASE PLYNEW CAP SHEET

    NEW WOOD BLOCKING

    NEW 5" x 38@ 24" O.C. MAX.

    EXISTING STRUCTURE

    EXISTING CONDUIT

    USE THIS SECTION ON SIDE WHERE CONDUIT PENETRATES ROOF HATCH FRAME ONLY

    EXISTING METAL FLASHING

    NEW BITUMINOUS SEALANT

    NEW BITUMINOUS SEALANT

    EXISTING BLOCKING

    NEW METAL FLASHING

    EXISTING LIGHTWEIGHT FILLOR NEW BASE INSULATIONOVER NEW VAPOR BARRIER

    NEW FILL INSULATION

    NEW TAPERED INSULATION

    NEW FILL INSULATIONNEW TAPERED INSULATION

    EXISTING WOOD BLOCKING

    EXISTING WOOD BLOCKING

  • NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW BASE PLY

    NEW LIQUID APPLIED FLASHING

    SHEET

    Det

    ails

    D3

    PF No. 11012.003.004

    DATE: 4-26-12

    SCALE: NTS

    DRAWN BY: WMM

    CHECKED BY: WBS

    1 TYPICAL DETAIL AT LOUVER 2 TYPICAL DETAIL AT CONCRETE CONDUIT STAND

    NEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY VAPOR BARRIER

    NEW CAP SHEETNEW BASE PLY

    NEW WALK PAD UNDERCONCRETE CONDUIT STAND

    EXISTING 13" x 36" CONCRETECONDUIT STAND

    EXISTING LOUVER

    3 TYPICAL PIPE PENETRATION DETAIL

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW STRIPPING PLY

    EXISTING PIPE

    NEW LIQUID APPLIED FLASHING

    4" MIN.4" MIN.

    8" M

    IN.

    NEW BITUMINOUS SEALANT

    NEW BASE PLY

    NEW BITUMINOUS SEALANT

    NEW STRIPPING PLY

    NEW METAL COUNTERFLASHINGNEW METAL RECEIVER

    EXISTING STRUCTURE

    EXISTING STRUCTURE

    VARIE

    S

    NEW BACKER RODAND SEALANT

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW STRIPPING PLY

    NEW BASE PLY

    NEW BATT INSULATION

    NEW 2" DIA. HOLENEW BITUMINOUS SEALANT

    NEW WOOD BLOCKING

    4 NEW ONE WAY VENT DETAIL

    NEW ONE WAY VENT

    USE THIS SECTION AT LOUVER WALL WHERE DOOR IS LOCATED

    TYPICAL DETAIL AT LOUVER

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW BASE PLY

    NEW LIQUID APPLIED FLASHINGNEW BITUMINOUS SEALANT

    NEW STRIPPING PLY

    EXISTING DOOR EXISTING METAL THRESHOLD

    EXISTING STRUCTURE

    4" MIN.(TYP.)

    4" MIN.4" MIN. 8" M

    IN.

    5 SAFETY ANCHOR BASE DETAIL

    NEW BASE INSULATIONNEW COVERBOARD

    NEW 2 PLY MEMBRANEOVER BASE SHEET

    NEW CAP SHEETNEW STRIPPING PLY

    NEW SAFETY ANCHORASSEMBLY

    NEW LIQUID APPLIED FLASHINGNEW BITUMINOUS SEALANT

    NEW BASE PLY

    NEW ANGLE IRON ASSEMBLY

    2'-0" MIN.

    NEW LIGHTWEIGHT FILLOR BASE INSULATION

    OVER VAPOR BARRIER

    EXISTING LIGHTWEIGHT FILLOR NEW BASE INSULATION

    OVER NEW VAPOR BARRIER

    EXISTING STRUCTURAL SLAB

    EXISTING LIGHTWEIGHT FILLOR NEW BASE INSULATIONOVER NEW VAPOR BARRIER

    NEW TAPERED INSULATION

  • SHEET

    Det

    ails

    D4

    PF No. 11012.003.004

    DATE: 4-26-12

    SCALE: NTS

    DRAWN BY: WMM

    CHECKED BY: WBS

    NEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY VAPOR BARRIER

    NEW CAP SHEETNEW BASE PLY

    NEW BASE FLASHINGNEW CANT

    NEW METAL COPING CAP

    NEW METAL LOCKING CLEAT

    NEW 20 MIL PVC FLASHING

    NEW WOOD BLOCKING WITH 1" x 1" NOTCH ON BOTTOM @ 24" O.C.

    4" x 38

    NEW 48" LONG WOOD BLOCKINGRAISED 1" OFF DECK WITH 2" SPACE

    BETWEEN BLOCKING PIECES

    NEW PLYWOOD SHEATHINGRAISED 12" OFF DECK

    3 PARAPET DETAIL

    EXISTING STRUCTURE

    1 TYPICAL ROOF DRAIN DETAIL 2 TYPICAL SANITARY VENT DETAIL

    NEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY VAPOR BARRIER

    NEW CAP SHEETNEW STRIPPING PLY

    EXISTING SANITARY VENT

    NEW LIQUID APPLIED FLASHING

    4" MIN.4" MIN. 8" M

    IN.

    NEW BITUMINOUS SEALANT

    NEW BASE PLY

    EXISTING STRUCTURE

    NEW TAPERED INSULATIONNEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY VAPOR BARRIER

    NEW CAP SHEETNEW STRIPPING PLY

    NEW TAPERED EDGE STRIPNEW LEAD FLASHING

    NEW BASE PLY

    NEW ROOF DRAIN

    NEW TAPERED INSULATION

    NEW BASE INSULATION

    NEW COVERBOARD

    NEW 2 PLY VAPOR BARRIER

    NEW CAP SHEETNEW STRIPPING PLY

    NEW BASE PLY

    NEW FOAM GLASS INSULATION

    NEW FLANGED METAL SLEEVENEW VENT BONNET

    EXISTING VENT BONNETEXISTING HOT VENT STACK

    4 TYPICAL HOT VENT STACK DETAIL

    3" MIN.

    NEW WOOD BLOCKING

    EXISTING STRUCTURE

    NEW TAPERED INSULATION

    NEW FILL INSULATIONNEW TAPERED INSULATION

    NEW FILL INSULATION

    K1-signedR1-signedR2-signedD1-signedD2-signedD3-signedD4-signed