the solution to change osn3500 subrack to osn7500 subrack
TRANSCRIPT
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
1/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page1, Total35
Update record
Date Update description Version Author
20130726 The first version V1.00 Jack Liu
20130828Add some steps for download data to equipment
Add some steps for clock and overhead bytes restorationV1.10 Jack Liu
20130830
Add Upload the NE you want changed before you get scripts
Add Attention for 1+1 protocol
Add the name of all trails terminated on this subrack should be
changed back to old namesin roll back part
V1.2 Peter Potancok
20130906 Add Search the trails after upload NE V1.3 Jack Liu
20130910
Add Record All alarms a fter Search the trails after upload NE
Add contact info of the R&D who will convert the script from
OSN3500 to OSN7500
Add Re-do the script export for whole Optical subnet
V1.4 Peter Potancok
20130911Add Record all optical power values from all optical ports
Add Optical power values checkV1.5 Peter Potancok
20131015
Add the diagram and description in Export script of OSN3500
Delete site information
Add topology
V1.6 Jack Liu
20131016Add send the board list of OSN3500 subrack and new OSN7500
subrack to R&D, board slot can be changedV1.7 Jack Liu
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
2/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page2, Total35
Object
1 Export script of OSN3500...................................................................................................................32 Freeze network, change OSN3500 script to OSN7500 script ...................................................................73 Backup in U2000...............................................................................................................................74 On site XXXX, equipment 75XXXX ............ ........ ......... ....... ........ ......... ........ ....... ........ ........ ......... .... 115 In U2000, import script, restore configuration .... ........ ........ ......... ....... ........ ........ ......... ....... ........ ........ . 136 In U2000, download the data to equipment OSN7500 ...... ........ ......... ........ ....... ......... ........ ........ ....... .... 157 Check the configurations between 75XXXX and XXXX. .... .... .... .... .... .... ... .... ... .... .... ... .... ... .... .... ... .... .. 218 Force MSP switch on both sides of site XXXX in the backbone........ .... .... .... .... ... .... ... .... .... ... .... ... .... .... . 229 Delete the 4f MSP STM64 ring which has XXXX from NM .... .... .... .... .... ... .... .... ... .... ... .... ... .... .... ... .... .. 2310 Delete line fibers from NMS layer .............. ........ ........ ....... ......... ........ ........ ....... ......... ........ ........ ... 2511 On site operation: equipment XXXX (1 hour) ............... ........ ........ ....... ......... ........ ........ ....... ......... .. 2612 On site operation: equipment 75XXXX (1.5 hours) ........ ........ ........ ........ ........ ........ ........ ........ ........ .. 2613 U2000 operation in the same time ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ .. 2614 Optical power values check.............. ........ ......... ....... ........ ........ ......... ....... ........ ........ ......... ....... ..... 2915 Checking alarms.......................................................................................................................... 2916 SDH trail search, check the names, quantity of trails, discrete trails .... .... .... .... ... .... ... .... ... .... ... .... .... ... . 2917 Deal with the problems............ ........ ......... ....... ........ ........ ......... ....... ........ ........ ......... ....... ........ ..... 3018 Roll back in case of problem ........ ........ ......... ....... ........ ........ ......... ....... ........ ........ ......... ....... ........ . 30
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
3/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page3, Total35
Solution to change OSN3500 subrack to OSN7500 subrack
XXXX is OSN3500 in MSP ring; now need to change to OSN7500, below are procedure
4f MSP ring and 2f MSP ring both can use this procedure
1 Export script of OSN3500
Step01: Do the upload of OSN3500 NE which is going to be changed to OSN7500
Configuration ---> NE Configuration Data Management
Selects the related NE and do the upload
Step02: Search SDH trails
Service---> SDH trail ---> Search for SDH trail
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
4/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page4, Total35
Use default value do the search, after search finished, click next
Click next
Click finish.
Step03: Record all Alarms
Fault > Browse Current Alarm
Select all alarms and save all alarms to one file in the pop up window.
Step04: Record all optical power values from all optical ports on OSN3500
Performance ---> Browse SDH Performance ---> Current Performance Data
Select the NE XXXX
Data source: Gauge
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
5/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page5, Total35
Performance Event type: Received Optical Power and Transmitted Optical Power
Query and save it to the excel file.
Step05: Export script
Administration---> Back up/Restore NMS Data ---> Import/Export Script file
Step06: Select Networkwide Configuration fileas the script file type
Step07: Create folder, you can change the folder name
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
6/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page6, Total35
Step08: Select the related NE and apply it.
Step09: Re-do the script export for whole Optical subnet and save it
You can use this script to restore the lived network data to the lab server. And then you can use lab
server restore the changed data to the new equipment. So you will save your operation time on site.
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
7/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page7, Total35
2 Freeze network, change OSN3500 script to OSN7500 script
1. Send scripts to HQ, HQ will take about 1~2 days to finish the change.
2. Send the board list of OSN3500 subrack and new OSN7500 subrack to R&D, board slot can be changed;
3.NEID should be different;.
4. Dont suggest changing the configuration on operated site.
5. Customer can create the pass through service on backbone, but it cant be restored by OSN7500 script,
it should be restored manually by adding cross connection on the operated site.
3 Backup in U2000
Step01: U2000 database
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
8/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page8, Total35
Step02: Equipment database of XXXX
Sselct
Select the NE you want to backup, click Backup
In the pop up window, click start
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
9/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page9, Total35
Step03: Trails in XXXX
Find the NE in the Topo, right mouse, select
Select save as
Click ok
Step04: Fibers in XXXX
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
10/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page10, Total35
C
Clicks saveas
Click , change to *.xls and UTF-8
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
11/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page11, Total35
4 On site XXXX, equipment 75XXXX
Step01: Checking Power Jumpers on the SSN6GSCC
Jumpers of the N6GSCC
Jumper Function Description
J18 To enable the battery 12: If jumper bits (positions) 1 and 2 are capped, the database and
clock are cleared.23: If ju mper bi ts (positions) 2 and 3 are capped, the battery is
enabled.
J11 To set the running state of the
board
Jumper J11 is a group of two-pin jumpers located in five rows. The
jumper in the left-most row is reserved and does not need to be set. In
the case of the jumpers in the r ight four rows, the value of a jumper bit
is defined as follows:
If a jumper bit is not capped, the value is 0.
If a jumper bit is capped, the value is 1.
The jumper bit values are queued from left to r ight and from the higher
bit to the lower bit, and form a four-bit b inary number. For detai ls, refer
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
12/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page12, Total35
Jumpers of the N6GSCC
Jumper Function Description
toTable 4.
J30 and
J31
To set the input voltage of the
equipment
23 or jumpers are not capped: If jumper bits (positions) 2 and 3 are
capped or jumpers are not capped, the equipment is supplied with the
60 V power.
12: If ju mper bi ts (positions) 2 and 3 are capped, the equipment is
supplied with the48 V power.
CAUTION:
Set J30 and J31 correctly based on the power voltage provided in the telecommunications room. If J30 and J31 are s et
incorrectly, the POW ER_ABNORMAL alarm is generated.
Table 4 Jumper J11
Value Description
0b0000 Indicates the running state when the watchdog is started. It is the default state.
0b0001 Changes to the self-test state of the SDRAM Burst.
0b0011 Indicates the commiss ioning state.
0b0100 Indicates the running state when the watchdog is stopped.
0b0101 The software is in the BIOS state. The SCC does not work even though the NE software
exists . The IP address of the parameter area, however, is not changed, which is for querying.
0b0110 The software enters the exhibit ion mode.
0b1001 Indicates the running state when the watchdog is started.
0b1011 Erases the database.
0b1100 Erases the NE software, includ ing the patches.
0b1101 Erases the database and NE software, including the patches .
0b1110 Erases the database, NE software, and NE.inifile.
0b1111 Erases the extended BIOS and system parameter area in the file system and flash memory.
Step02: Connect power cable to OSN7500 temporary; remember to connect the protection GND;
Step03: Resistance check
Checking Resistance between the Power Input Terminals of the DC PDU according to the
installation manual of OSN 7500 V2R11C02
Step04: Power on OSN7500
Step05: Built the connection between U2000 and 75XXXX, so U2000 can manage 75XXXX
http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368 -
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
13/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page13, Total35
5 In U2000, import script, restore configuration
Step01: Import the site 75XXXX script to U2000 according to below picture
Select NE Configuration file;
Select Import,
Select the related folder,
Select the related NE file and then click Apply
Click ok
Click ok
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
14/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page14, Total35
Step02: Move 75XXXX to the subnet which include XXXX;
Step03: Checking cross connections in XXXX and 75XXXX,
You can copy cross connections to table to compare them, they should be same.
Step04: Restore clock, Ethernet port parameters, bounding relationship, overhead bytes;
Query the configurations in XXXX and then configure the same value in 75XXXX
Clock source Priority, c lock subnet configuration (protection s tatus, configured quality)
Overhead of boards (J0 to be sent, J0 to be received, query in XXXX and then change it in
SH75XXXX)
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
15/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page15, Total35
6 In U2000, download the data to equipment OSN7500
You should change preconfigured NE to configured NE, switch NE user and then download data from
U2000 to equipment
Click No
Interface: switch NE user
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
16/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page16, Total35
Unselect all NE
Click
Click Selectand then click c lose
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
17/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page17, Total35
Click
Click Switch NE User
Switch to user rootby password password(for example, password is password)
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
18/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page18, Total35
Interface: Download data to equipment
Unselect all NE
Find and select the related NE
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
19/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page19, Total35
Download to equipment
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
20/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page20, Total35
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
21/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page21, Total35
7 Check the configurations between 75XXXX and XXXX.
Synchronize NE time with NMS and start 15min and 24h performance monitoring
Be notice to check the MSP parameters in NE explorer
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
22/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page22, Total35
Normally 30 minutes
8 Force MSP switch on both sides of site XXXX in the backbone.
Only pass through backbone service will be protected, other service will be broken down.
For example, site XXXX: you should force switch slot11 on YYYY and slot8 on ZZZZ
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
23/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page23, Total35
9 Delete the 4f MSP STM64 ring which has XXXX from NM
Step01: Access in
Step02: Find XXXX and close it
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
24/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page24, Total35
Step03: Delete the related 4f MSP ring from NM
Step04: Select Yes
Step05: Select Continueand then close it.
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
25/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page25, Total35
10 Delete line fibers from NMS layer
Step01: Find the NE and right click mouse, select Query relevant fibers
Step02: Select all fibers, right mouse, select delete fiber/Cable from NMS
Step03: Select continue, select ok, and close it
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
26/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page26, Total35
11 On site operation: equipment XXXX (1 hour)
Step01: Power down OSN3500, remove cables and fibers
Step02: Remove subrack
12 On site operation: equipment 75XXXX (1.5 hours)
Step01: Power down OSN7500;
Step02: Install OSN7500 subrack, connect power cables and protection GND;
Step03: Power on OSN7500;
Step04: Add boards; connect cables and fibers on site
13 U2000 operation in the same time
Restore all fibers that deleted in U2000 on site XXXX: Original is connect to XXXX, now should change to
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
27/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page27, Total35
75XXXX
Step01: Search protection subnet
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
28/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page28, Total35
Step02: Check the new found MSP subnet, 75XXXX should be inside
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
29/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page29, Total35
Step03: Clear force
After operation on 75XXXX finished, clear force MSP switch on site YYYY and ZZZZ, dropped
service will be back.
14 Optical power values check
Compare previously recorded optical power values from OSN3500 with current ones on OSN7500.
15 Checking alarms
Check alarms.
16 SDH trail search, check the names, quantity of trails, discrete trails
Step01: Trail searching
Step02: Check the trail names, quantities and discrete trails
All trails terminated on OSN7500 (OSN3500 before) directly have to be renamed manually.
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
30/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page30, Total35
17 Deal with the problems
18 Roll back in case of problem
Only 1 hour can be used in case of problem after subrack change, if problem cant be fixed in one hour, you
should roll back to XXXX.
Step01: Force switch on both sides of site XXXX
For example, site YYYY: you should force switch slot11 on YYYY and slot8 on ZZZZ
Step02: Delete the 4f MSP subnet that has 75XXXX
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
31/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page31, Total35
You should delete the 4f MSP subnet from NM
Service --> SDH protection subnet --> Manage SDH protection subnet
Ensure 75XXXX is in this subnet and then click close
And then delete the subnet from the NM
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
32/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page32, Total35
Step03: Delete all fibers connect to 75XXXX from NM layer
Select all fibers, and then delete fiber/cable from NMS
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
33/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page33, Total35
Step04: Power down OSN7500, remove power cables, other cables, fibers
Step05: Uninstall OSN7500 subrack.
Step06: Install OSN3500 subrack, connect power cables, protection GND cable;
Step07: Power on OSN3500, add boards, fibers and other cables
Step08: Same time, restore fibers in U2000 that connect to XXXX
And then use the fiber table in chapter 3.4 to restore the connections
Step09: Search protection subnet, new 4f MSP protection subnet should has XXXX
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
34/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
2014-01-08 Huawei Proprietary - Restricted Distribution Page34, Total35
Step10: Clear force
-
8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack
35/35
The solution to change OSN3500 subrack to OSN7500 subrack Public
Clear force switch on both side sites of site XXXX, for example, site XXXX: you should clear force
switch on site YYYY and ZZZZ.
Step11: SDH trail search, manually restore the trails terminated on site XXXX
Step12: Fix the problem