the solution to change osn3500 subrack to osn7500 subrack

Upload: thunder-linkcom

Post on 03-Jun-2018

246 views

Category:

Documents


1 download

TRANSCRIPT

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    1/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page1, Total35

    Update record

    Date Update description Version Author

    20130726 The first version V1.00 Jack Liu

    20130828Add some steps for download data to equipment

    Add some steps for clock and overhead bytes restorationV1.10 Jack Liu

    20130830

    Add Upload the NE you want changed before you get scripts

    Add Attention for 1+1 protocol

    Add the name of all trails terminated on this subrack should be

    changed back to old namesin roll back part

    V1.2 Peter Potancok

    20130906 Add Search the trails after upload NE V1.3 Jack Liu

    20130910

    Add Record All alarms a fter Search the trails after upload NE

    Add contact info of the R&D who will convert the script from

    OSN3500 to OSN7500

    Add Re-do the script export for whole Optical subnet

    V1.4 Peter Potancok

    20130911Add Record all optical power values from all optical ports

    Add Optical power values checkV1.5 Peter Potancok

    20131015

    Add the diagram and description in Export script of OSN3500

    Delete site information

    Add topology

    V1.6 Jack Liu

    20131016Add send the board list of OSN3500 subrack and new OSN7500

    subrack to R&D, board slot can be changedV1.7 Jack Liu

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    2/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page2, Total35

    Object

    1 Export script of OSN3500...................................................................................................................32 Freeze network, change OSN3500 script to OSN7500 script ...................................................................73 Backup in U2000...............................................................................................................................74 On site XXXX, equipment 75XXXX ............ ........ ......... ....... ........ ......... ........ ....... ........ ........ ......... .... 115 In U2000, import script, restore configuration .... ........ ........ ......... ....... ........ ........ ......... ....... ........ ........ . 136 In U2000, download the data to equipment OSN7500 ...... ........ ......... ........ ....... ......... ........ ........ ....... .... 157 Check the configurations between 75XXXX and XXXX. .... .... .... .... .... .... ... .... ... .... .... ... .... ... .... .... ... .... .. 218 Force MSP switch on both sides of site XXXX in the backbone........ .... .... .... .... ... .... ... .... .... ... .... ... .... .... . 229 Delete the 4f MSP STM64 ring which has XXXX from NM .... .... .... .... .... ... .... .... ... .... ... .... ... .... .... ... .... .. 2310 Delete line fibers from NMS layer .............. ........ ........ ....... ......... ........ ........ ....... ......... ........ ........ ... 2511 On site operation: equipment XXXX (1 hour) ............... ........ ........ ....... ......... ........ ........ ....... ......... .. 2612 On site operation: equipment 75XXXX (1.5 hours) ........ ........ ........ ........ ........ ........ ........ ........ ........ .. 2613 U2000 operation in the same time ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ ........ .. 2614 Optical power values check.............. ........ ......... ....... ........ ........ ......... ....... ........ ........ ......... ....... ..... 2915 Checking alarms.......................................................................................................................... 2916 SDH trail search, check the names, quantity of trails, discrete trails .... .... .... .... ... .... ... .... ... .... ... .... .... ... . 2917 Deal with the problems............ ........ ......... ....... ........ ........ ......... ....... ........ ........ ......... ....... ........ ..... 3018 Roll back in case of problem ........ ........ ......... ....... ........ ........ ......... ....... ........ ........ ......... ....... ........ . 30

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    3/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page3, Total35

    Solution to change OSN3500 subrack to OSN7500 subrack

    XXXX is OSN3500 in MSP ring; now need to change to OSN7500, below are procedure

    4f MSP ring and 2f MSP ring both can use this procedure

    1 Export script of OSN3500

    Step01: Do the upload of OSN3500 NE which is going to be changed to OSN7500

    Configuration ---> NE Configuration Data Management

    Selects the related NE and do the upload

    Step02: Search SDH trails

    Service---> SDH trail ---> Search for SDH trail

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    4/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page4, Total35

    Use default value do the search, after search finished, click next

    Click next

    Click finish.

    Step03: Record all Alarms

    Fault > Browse Current Alarm

    Select all alarms and save all alarms to one file in the pop up window.

    Step04: Record all optical power values from all optical ports on OSN3500

    Performance ---> Browse SDH Performance ---> Current Performance Data

    Select the NE XXXX

    Data source: Gauge

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    5/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page5, Total35

    Performance Event type: Received Optical Power and Transmitted Optical Power

    Query and save it to the excel file.

    Step05: Export script

    Administration---> Back up/Restore NMS Data ---> Import/Export Script file

    Step06: Select Networkwide Configuration fileas the script file type

    Step07: Create folder, you can change the folder name

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    6/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page6, Total35

    Step08: Select the related NE and apply it.

    Step09: Re-do the script export for whole Optical subnet and save it

    You can use this script to restore the lived network data to the lab server. And then you can use lab

    server restore the changed data to the new equipment. So you will save your operation time on site.

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    7/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page7, Total35

    2 Freeze network, change OSN3500 script to OSN7500 script

    1. Send scripts to HQ, HQ will take about 1~2 days to finish the change.

    2. Send the board list of OSN3500 subrack and new OSN7500 subrack to R&D, board slot can be changed;

    3.NEID should be different;.

    4. Dont suggest changing the configuration on operated site.

    5. Customer can create the pass through service on backbone, but it cant be restored by OSN7500 script,

    it should be restored manually by adding cross connection on the operated site.

    3 Backup in U2000

    Step01: U2000 database

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    8/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page8, Total35

    Step02: Equipment database of XXXX

    Sselct

    Select the NE you want to backup, click Backup

    In the pop up window, click start

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    9/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page9, Total35

    Step03: Trails in XXXX

    Find the NE in the Topo, right mouse, select

    Select save as

    Click ok

    Step04: Fibers in XXXX

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    10/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page10, Total35

    C

    Clicks saveas

    Click , change to *.xls and UTF-8

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    11/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page11, Total35

    4 On site XXXX, equipment 75XXXX

    Step01: Checking Power Jumpers on the SSN6GSCC

    Jumpers of the N6GSCC

    Jumper Function Description

    J18 To enable the battery 12: If jumper bits (positions) 1 and 2 are capped, the database and

    clock are cleared.23: If ju mper bi ts (positions) 2 and 3 are capped, the battery is

    enabled.

    J11 To set the running state of the

    board

    Jumper J11 is a group of two-pin jumpers located in five rows. The

    jumper in the left-most row is reserved and does not need to be set. In

    the case of the jumpers in the r ight four rows, the value of a jumper bit

    is defined as follows:

    If a jumper bit is not capped, the value is 0.

    If a jumper bit is capped, the value is 1.

    The jumper bit values are queued from left to r ight and from the higher

    bit to the lower bit, and form a four-bit b inary number. For detai ls, refer

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    12/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page12, Total35

    Jumpers of the N6GSCC

    Jumper Function Description

    toTable 4.

    J30 and

    J31

    To set the input voltage of the

    equipment

    23 or jumpers are not capped: If jumper bits (positions) 2 and 3 are

    capped or jumpers are not capped, the equipment is supplied with the

    60 V power.

    12: If ju mper bi ts (positions) 2 and 3 are capped, the equipment is

    supplied with the48 V power.

    CAUTION:

    Set J30 and J31 correctly based on the power voltage provided in the telecommunications room. If J30 and J31 are s et

    incorrectly, the POW ER_ABNORMAL alarm is generated.

    Table 4 Jumper J11

    Value Description

    0b0000 Indicates the running state when the watchdog is started. It is the default state.

    0b0001 Changes to the self-test state of the SDRAM Burst.

    0b0011 Indicates the commiss ioning state.

    0b0100 Indicates the running state when the watchdog is stopped.

    0b0101 The software is in the BIOS state. The SCC does not work even though the NE software

    exists . The IP address of the parameter area, however, is not changed, which is for querying.

    0b0110 The software enters the exhibit ion mode.

    0b1001 Indicates the running state when the watchdog is started.

    0b1011 Erases the database.

    0b1100 Erases the NE software, includ ing the patches.

    0b1101 Erases the database and NE software, including the patches .

    0b1110 Erases the database, NE software, and NE.inifile.

    0b1111 Erases the extended BIOS and system parameter area in the file system and flash memory.

    Step02: Connect power cable to OSN7500 temporary; remember to connect the protection GND;

    Step03: Resistance check

    Checking Resistance between the Power Input Terminals of the DC PDU according to the

    installation manual of OSN 7500 V2R11C02

    Step04: Power on OSN7500

    Step05: Built the connection between U2000 and 75XXXX, so U2000 can manage 75XXXX

    http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368http://support.huawei.com/hedex/pages/SE000063677531185228/03/SE000063677531185228/03/resources/osn/ig/topic/tc_osn_ig_8002.html?ft=0&id=tc_osn_ig_8002#tc_osn_ig_8002__d7277e368
  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    13/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page13, Total35

    5 In U2000, import script, restore configuration

    Step01: Import the site 75XXXX script to U2000 according to below picture

    Select NE Configuration file;

    Select Import,

    Select the related folder,

    Select the related NE file and then click Apply

    Click ok

    Click ok

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    14/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page14, Total35

    Step02: Move 75XXXX to the subnet which include XXXX;

    Step03: Checking cross connections in XXXX and 75XXXX,

    You can copy cross connections to table to compare them, they should be same.

    Step04: Restore clock, Ethernet port parameters, bounding relationship, overhead bytes;

    Query the configurations in XXXX and then configure the same value in 75XXXX

    Clock source Priority, c lock subnet configuration (protection s tatus, configured quality)

    Overhead of boards (J0 to be sent, J0 to be received, query in XXXX and then change it in

    SH75XXXX)

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    15/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page15, Total35

    6 In U2000, download the data to equipment OSN7500

    You should change preconfigured NE to configured NE, switch NE user and then download data from

    U2000 to equipment

    Click No

    Interface: switch NE user

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    16/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page16, Total35

    Unselect all NE

    Click

    Click Selectand then click c lose

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    17/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page17, Total35

    Click

    Click Switch NE User

    Switch to user rootby password password(for example, password is password)

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    18/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page18, Total35

    Interface: Download data to equipment

    Unselect all NE

    Find and select the related NE

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    19/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page19, Total35

    Download to equipment

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    20/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page20, Total35

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    21/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page21, Total35

    7 Check the configurations between 75XXXX and XXXX.

    Synchronize NE time with NMS and start 15min and 24h performance monitoring

    Be notice to check the MSP parameters in NE explorer

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    22/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page22, Total35

    Normally 30 minutes

    8 Force MSP switch on both sides of site XXXX in the backbone.

    Only pass through backbone service will be protected, other service will be broken down.

    For example, site XXXX: you should force switch slot11 on YYYY and slot8 on ZZZZ

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    23/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page23, Total35

    9 Delete the 4f MSP STM64 ring which has XXXX from NM

    Step01: Access in

    Step02: Find XXXX and close it

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    24/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page24, Total35

    Step03: Delete the related 4f MSP ring from NM

    Step04: Select Yes

    Step05: Select Continueand then close it.

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    25/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page25, Total35

    10 Delete line fibers from NMS layer

    Step01: Find the NE and right click mouse, select Query relevant fibers

    Step02: Select all fibers, right mouse, select delete fiber/Cable from NMS

    Step03: Select continue, select ok, and close it

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    26/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page26, Total35

    11 On site operation: equipment XXXX (1 hour)

    Step01: Power down OSN3500, remove cables and fibers

    Step02: Remove subrack

    12 On site operation: equipment 75XXXX (1.5 hours)

    Step01: Power down OSN7500;

    Step02: Install OSN7500 subrack, connect power cables and protection GND;

    Step03: Power on OSN7500;

    Step04: Add boards; connect cables and fibers on site

    13 U2000 operation in the same time

    Restore all fibers that deleted in U2000 on site XXXX: Original is connect to XXXX, now should change to

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    27/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page27, Total35

    75XXXX

    Step01: Search protection subnet

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    28/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page28, Total35

    Step02: Check the new found MSP subnet, 75XXXX should be inside

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    29/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page29, Total35

    Step03: Clear force

    After operation on 75XXXX finished, clear force MSP switch on site YYYY and ZZZZ, dropped

    service will be back.

    14 Optical power values check

    Compare previously recorded optical power values from OSN3500 with current ones on OSN7500.

    15 Checking alarms

    Check alarms.

    16 SDH trail search, check the names, quantity of trails, discrete trails

    Step01: Trail searching

    Step02: Check the trail names, quantities and discrete trails

    All trails terminated on OSN7500 (OSN3500 before) directly have to be renamed manually.

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    30/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page30, Total35

    17 Deal with the problems

    18 Roll back in case of problem

    Only 1 hour can be used in case of problem after subrack change, if problem cant be fixed in one hour, you

    should roll back to XXXX.

    Step01: Force switch on both sides of site XXXX

    For example, site YYYY: you should force switch slot11 on YYYY and slot8 on ZZZZ

    Step02: Delete the 4f MSP subnet that has 75XXXX

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    31/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page31, Total35

    You should delete the 4f MSP subnet from NM

    Service --> SDH protection subnet --> Manage SDH protection subnet

    Ensure 75XXXX is in this subnet and then click close

    And then delete the subnet from the NM

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    32/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page32, Total35

    Step03: Delete all fibers connect to 75XXXX from NM layer

    Select all fibers, and then delete fiber/cable from NMS

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    33/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page33, Total35

    Step04: Power down OSN7500, remove power cables, other cables, fibers

    Step05: Uninstall OSN7500 subrack.

    Step06: Install OSN3500 subrack, connect power cables, protection GND cable;

    Step07: Power on OSN3500, add boards, fibers and other cables

    Step08: Same time, restore fibers in U2000 that connect to XXXX

    And then use the fiber table in chapter 3.4 to restore the connections

    Step09: Search protection subnet, new 4f MSP protection subnet should has XXXX

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    34/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    2014-01-08 Huawei Proprietary - Restricted Distribution Page34, Total35

    Step10: Clear force

  • 8/12/2019 The Solution to Change OSN3500 Subrack to OSN7500 Subrack

    35/35

    The solution to change OSN3500 subrack to OSN7500 subrack Public

    Clear force switch on both side sites of site XXXX, for example, site XXXX: you should clear force

    switch on site YYYY and ZZZZ.

    Step11: SDH trail search, manually restore the trails terminated on site XXXX

    Step12: Fix the problem