touch for eco-friendly heating - termodinamik.com.uatermodinamik.com.ua/files/central...
TRANSCRIPT
touch for eco-friendlyheating...
Trusth this warmth...
45 kW-120 kW
ww
w.te
rmod
inam
ik.c
om.tr
1
NEWPRODUCT
Natural Gas FiredLow EmissionElectronic Ignition System
ww
w.te
rmod
inam
ik.c
om.tr
2
ECO-FRIENDLYTECHNOLOGY
45- 60-90-120 kW capacity,Aluminium heat exchanger with high efficiency (108%),Wall hung type,Hermetic type,Capacity and efficiency are higher than convertional wall hung boilers,Gas is mixed with air through the venturi mixer (1:11.75); that allows to reach high efficiency and reduce gas expenses, Aluminium heat exchanger with special insulation to prevent heat losses,Ionisation flame control electronic nozzle,NTC-controlled temperature adjustment,Control panel with LCD display,Pump and three-way valve are controlled by electronic card system, Low water pressure switch,High water pressure relief valve,Air purge protection,Eco-friendly with low emission rates,Cascade installation.
Waste gas outlet
Fresh air inlet
Hot wateroutlet
Condensing wateroutlet
Cold waterinlet
Gas inlet
TERMOMİDİ 60TERMOMİDİ 90TERMOMİDİ 120
60 1:51:51:5
0.8-40.8-4
0.8-4
Ø80Ø100Ø100
108TERMOMİDİ 45 45 1:5 0.8-4 Ø80 108
108108
90120
ModelMaks.
NominalLoad (kW)
ModulationLevel
OperatingPressure
(bar)
Flue Connection
(mm)
LoadEfficiency %30(50-30°C)%
We are reserved the right to make changes in dimensions and appearance.
160 kW-280 kW
ww
w.te
rmod
inam
ik.c
om.tr
3
NEWPRODUCT
Natural Gas FiredLow Emission
High Water Pressure Protection
ECO-FRIENDLYTECHNOLOGY
ww
w.te
rmod
inam
ik.c
om.tr
4
We are reserved the right to make changes in dimensions and appearance.
Model
TERMOMAXI 160-5TERMOMAXI 200-6TERMOMAXI 240-7TERMOMAXI 280-8
107.5107.5107.5107.5
97.498.498.498.4
160 27200 44240 48280 52
Max. Nominal
Load (kW)
Min. Nominal
Load (kW)
Efficiency at Max. Load (80-60°C)%
%30 Load Efficiency
(50-30°C)%
Model
TERMOMAXI 160-5TERMOMAXI 200-6TERMOMAXI 240-7TERMOMAXI 280-8
850107010701070
640640640640
0.8 60.8 60.8 60.8 6
90909090
Max. Flow Temp.
°C
Min. Operating
Pressure(bar)
Max. Operating
Pressure(bar)
BodyWidth(mm)
BodyDepth(mm)
180210227245
1190
119011901190
BodyHigh
(mm) Weight
(kg)
Control panel with LCD display,Aluminium heat exchanger with high efficiency (108%),Removable aluminium plates of heat exchangers allow to adjust the heating capacity between 160-280 kW,Size is much smaller than conventional boilers with the same capacity,Cascade installation,Gas is mixed with air through the venturi mixer (1:11.75); that allows to reach high efficiency and reduce gas expenses,Hermetic design without room air consumption,Aluminium heat exchanger with special insulation to prevent heat losses,Ionisation flame control electronic nozzle,NTC-controlled temperature adjustment,Air purge protection,6 bar safety valve and high water pressure protection,Fan and gas modulation valve,In order to compensate the risk of damage by the waste water appeared as the result of condensation, optionally additional neutralizing system is offered to be installed,Eco-friendly with low emission rates.
Hot water outlet
Gas inlet
Exhaust gasflue
Cold Water Inlet
Fresh air inlet
320 kW-620 kW
ww
w.te
rmod
inam
ik.c
om.tr
5
NEWPRODUCT
Natural Gas FiredCascade TechnologyLow Emission
High Water Pressure Protection
ECO-FRIENDLYTECHNOLOGY
ww
w.te
rmod
inam
ik.c
om.tr
6
Maks. Çalışma Baca %30 Yükteki
Control panel with LCD display,Aluminium heat exchanger with high efficiency (108%),Aluminium heat exchangers are used for boilers with capacity 320-620 kW,Size is much smaller than conventional boilers with the same capacity,Cascade installation,Gas is mixed with air through the venturi mixer (1:11.75); that allows to reach high efficiency and reduce gas expenses,Hermetic design without room air consumption,Aluminium heat exchanger with special insulation to prevent heat losses,Ionisation flame control electronic nozzle,NTC-controlled temperature adjustment,Air purge protection,High water pressure protection with 6 bar safety valve, Fan and gas modulation valve,In order to compensate the risk of damage by the waste water appeared as the result of condensation, optionally additional neutralizing system is offered to be installed,Eco-friendly with low emission rates.
Fresh air inlet
Hot water outlet
Gas inlet
Cold water inlet
Waste gas outlet
We are reserved the right to make changes in dimensions and appearance.
Model
TERMOMEGA 320TERMOMEGA 395TERMOMEGA 470TERMOMEGA 545TERMOMEGA 620
1:51:51:51:51:5
Ø250Ø250Ø250Ø250Ø250
108108108108108
0.8-60.8-60.8-60.8-60.8-6
320395470545620
Maks. Nominal
Load (kW)Modulation
Level
OperatingPressure
(bar)
FlueConnection
(mm)%30
Load Efficiency
(50-30°C)%
ww
w.te
rmod
inam
ik.c
om.tr
7
350 kW
NEWPRODUCT 5 BAR
Natural Gas FiredHigh Performance
ECO-FRIENDLYTECHNOLOGY
ww
w.te
rmod
inam
ik.c
om.tr
8
L
We are reserved the right to make changes in dimensions and appearance.
DIMENSIONSCapacity
kWModel
YCS 300 350 1200 16501470 20501420
A(mm)
A1(mm)
B(mm)
C(mm)
D(mm)
Model
YCS 300 R 3/4R1 1/2˝R 2 1/2 ˝Ø250920 560 900
E(mm) (mm) (mm) (mm)
F(mm)
ØGflue
(mm)H J
Input-OutputK
Expansion TankOutput
L Filling
Discharge
Increased heat transfer and lower dimensions of the boiler due to corrugated surface of combustion chamber,To archieve higher performance and accelerate condensation heat transfer, the heat exchanger has been designed with chrome plates,Since cold water returns to the bottom of the boiler, it's evenly distributed along the boiler,Fuel economy has been ensured due to low flue temperature and high heat transfer,Environmentally harmful exhaust gas emission is quite low,Engineered with long-term expertise in design and production,To ensure long term operation high quality components and material have been applied to production,Low costs of maintainance,Easy-to-operate control panel,Operates with natural gas burner of any trade mark.
ww
w.te
rmod
inam
ik.c
om.tr
9
81 kW - 2326 kW
5, 6, 8 BARLiquid/Gas Fired4-pass Construction
ww
w.te
rmod
inam
ik.c
om.tr
10
AØJ
ØM
H
ØK
G
C
D
ØJ
I B
HIGH PERFORMANCEWITH FOUR PASS DESIGN
Reliable design of the boilers with capacity range from 81 to 2326 kW to meet different needs,Different fuel options, high efficiency, clean and quiet operation,Resistant to high temperature steel applied to the boiler's body ensures efficient operation even in the most severe conditions,Due to optimization of the heat transfer surface efficiency is around 92%,Exterior cover sheets are painted with electrostatic salt, easy to install and insulated with glass wool,Simple operation is ensured by control panel mounted on the upper cover. The temperature can be observed and adjusted by means of thermometer and adjustable thermometer on the control panel.
ModelCapacity
kW
ECS 70ECS 85ECS 100
ECS 250
ECS 400
ECS 900
ECS 150
ECS 300
ECS 700
ECS 500
ECS 1000
ECS 200
ECS 350
ECS 800
ECS 600
91081
291349
99116
407
930
174
465
1046
232
582698814
1162
956 760910 956 760
910910 956910 956 1202
1378
2200
1577
1899
2716
1135
1647
2354
170
170
170
225
460
714
450
920
390
415
470
200
220
300
170
170
170
225
510
849
450
1020
390
415
470
200
220
300
170
170
170
300
600
822
600
1200
390
415
608
200
220
350
170
170
170
446
534
942
892
1068
390
506
608
200
250
350
170
170
170
410
704
1067
820
213418841644169814281408
415
506
608
220
250
350
1135
1747
2524
10401040104010401300130013601360146014601460
10621062106210621287128713141314146714671467
1130
123013301510
1718173820081960
2450
1547
2239
2967
1285
1927
2476
A(mm)
B(mm)
C(mm)
D(mm)
E(mm)
F(mm)
G(mm)
H(mm)
ØMFlue
R 2˝ R1 1/4˝ R 3/4˝
R 3/4˝
R 3/4˝
5 6 86 86 86 86 86 86 86 86 86 86 86 86 86 86 8
7.5 9 129 129 129 129 129 129 129 129 129 129 129 129 129 129 12
7.57.57.57.57.57.57.57.57.57.57.57.57.57.5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R 3/4˝
R1 1/4˝R1 1/4˝R1 1/4˝
R 2 1/2˝R 2 1/2˝
R 2 1/2˝
R 2˝R 2˝R 2˝
R 3˝R 3˝R 3˝R 3˝R 4˝R 4˝R 4˝
ECS 1250 1454 170 980 1960 1220 3501858 1811 2276 2811 7.55R 3/4˝R 2 1/2˝R 5˝ECS 1500 1745 170 1208 2416 1220 3501858 1811 2732 3434 7.55R 3/4˝
R 3/4˝R 3/4˝
R 2 1/2˝R 5˝ECS 1750 2035 170 1061 2122 1351 3502041 2036 2442 3062 7.55R 5˝ECS 2000 2326 170 1206 2412 1351
1042
1141
1392
1042
1141
1392
1042
1141
1543
1042
1365
1543
1141
1365
1543
I(mm)
1903190324252425 3502041 2036 2732 3352 7.55R 3˝
R 3˝R 5˝
R 2 1/2˝R 2 1/2˝R 2 1/2˝R 2 1/2˝
R 1/2˝R 1/2˝R 1/2˝R 1/2˝
2˝2˝2˝2˝
J Input
Output
K Expansion
Tank Output
L Filling
Discharge
OperatingPressure
(Bar)
Test Pressure
(Bar)
We are reserved the right to make changes in dimensions and appearance.
ww
w.te
rmod
inam
ik.c
om.tr
11
116 kW - 456 kW
EKY 125-EKY 250
EKY 300-EKY 500
3, 5, 6, 8 BARSolid Fuel4-pass ConstructionManual Loading
NEWPRODUCT
ww
w.te
rmod
inam
ik.c
om.tr
12
A
B
D
C
K
H
J
365
mm
338
mm
L
MøJ
HE
EKY 300-EKY 500 EKY 125-EKY 250
790790790790942
A(mm)
15201680168018401980
B(mm)
1735
173516501650
1760
C(mm)
1380
122012201060
1570
D(mm)
370520520680700
(mm)Model
EKY 125EKY 150EKY 175EKY 200EKY 250
116138165186234
1526 2140 1750 1530 500EKY 300 2761526 2140 1940 1530 500EKY 350 3211713 2230 1977 1770 500EKY 400 3691713 2230 2070 1770 500EKY 450 4231713 2390 2170 1930 500EKY 500 456
Capacity(Pellet)
Kw
E
R 1 1/4˝R 1 1/4˝R 1 1/4˝R 1 1/4˝R 1 1/4˝
J (Expansion Tank
Inlet-Outlet)
R 1 1/4˝R 1 1/4˝R 1 1/4˝R 1 1/4˝R 1 1/4˝
R1 1/2˝R1 1/2˝
R 2˝R 2˝
R 2 1/2˝
H (BoilerInlet-Outlet)
R 3˝R 3˝R 4˝R 4˝R 4˝
15201520160516051630
K (mm)
16001770177018552015
Model
EKY 125EKY 150EKY 175EKY 200EKY 250EKY 300EKY 350EKY 400EKY 450EKY 500
256246236
290518
WaterVolume
(L)
930950
10501000
1290
Weight(kg)
OperatingPressure
(bar)
5 6 88888
6666
5555
Test Pressure(bar)
4.54.5
4.54.54.5
9 12121212
12
9999
700 1350865 4.5 129
930 1550865 4.5 129
1240 2100865 4.5 129
1350 2300865 4.5 129
1430 2500865 4.5 129
R 3/4˝R 3/4˝R 3/4˝R 3/4˝R 3/4˝
L (Boiler Filling
Discharge)
ØM(mm)Flue PipeDiameter
250250250250250
R 3/4˝ 350R 3/4˝ 350R 3/4˝ 500R 3/4˝ 500R 3/4˝ 500
HIGH PERFORMANCEWITH FOUR PASS DESIGN
We are reserved the right to make changes in dimensions and appearance.
Prismatic central heating boilers of EKY 125-500 models have been engineered in five different capacities for solid fuel burning,In order to increase operation life cycle of the boiler, thicker steel and cast iron have been applied to its production,Four-pass construction ensures high thermal efficiency and low flue gas emission.
Digital control panel: EKY boilers are operated with digital control panel which provides precise and efficient control and contributes to longer operation life of the boiler. Safety: The boiler's water temperature is set with the thermostat on the digital control panel. If for any reason the water temperature rises to 100 ° C, limit thermostat is activated and fan operation is stopped. The boiler has to be restarted manually.
Fuel warning: The superiority of EKY boilers is to prevent unnecessary operation of the fan indicating burnout on the control panel when out-of-fuel.
Flue flap: EKY boilers are equipped with flue flap in order to achieve fuel saving for high draught flues. It can be adjusted easily by the user due to its position visible from outside.
BD
E
K
C
A
ww
w.te
rmod
inam
ik.c
om.tr
13
116 kW - 456 kW
EKY/S 125-EKY/S 250
EKY/S 300-EKY/S 500
NEWPRODUCT
3, 5, 6, 8 BARSolid Fuel4-pass Construction
Manual Loading
High TechnologyBurning Chamber
ww
w.te
rmod
inam
ik.c
om.tr
14
H C K
J
365
mm
338
mm
I
Mø
450 mm
1200
mm
J
AF
DB
H E
FA 680
BD
E
1300
K
C
EKY/S 125-EKY/S 250 EKY/S 300-EKY/S 500 OperatingPressure
(bar)
5 6 88888
6666
5555
Test Pressure(bar)
4.54.5
4.54.54.5
9 12121212
12
9999
R 1 1/4˝R 1 1/4˝R 1 1/4˝R 1 1/4˝R 1 1/4˝
J (Expansion Tank Inlet-Outlet)
R1 1/2˝R1 1/2˝
R 2˝R 2˝
R 2 1/2˝
H (BoilerInlet-Outlet)
ØM(mm)Flue PipeDiameter
250250250250250
256246236
290518700930
124013501430
(L)
930950
10501000
1290150017002290
24202600
865 4.5 129R 1 1/4˝R 3˝350865 4.5 129R 1 1/4˝R 3˝350865 4.5 129R 1 1/4˝R 4˝500865 4.5 129R 1 1/4˝R 4˝500865 4.5 129R 1 1/4˝R 4˝500
Weight(kg)
15201520160516051630
K (mm)
R 3/4˝R 3/4˝R 3/4˝R 3/4˝R 3/4˝
FillingDischarge)
1600 R 3/4˝1770 R 3/4˝1770 R 3/4˝1855 R 3/4˝2015 R 3/4˝
370520520680700
E (mm)
14701470147014701580
F (mm)
500 1760500 1760500 1960500 1960500 1960
WaterVolume
L (Boiler
790790790790942
A(mm)
14001560156017202140
B(mm)
1735
173516501650
1760
C(mm)
1380
122012201060
1570
D(mm)Model
EKY/S 125EKY/S 150EKY/S 175EKY/S 200EKY/S 250
116138165186234
1081 2140 1750 1530EKY/S 300 2761081 2140 1940 1530EKY/S 350 3211280 2230 1977 1770EKY/S 400 3691280 2230 2070 1770EKY/S 450 4231280 2390 2170 1930EKY/S 500 456
(Pellet)Kw
Capacity
HIGH PERFORMANCEWITH FOUR PASS DESIGN
We are reserved the right to make changes in dimensions and appearance.
Prismatic central heating boilers of EKY/S 125-500 models are compatible with instant water heaters (boilers) within our product range,Prismatic central heating boilers of EKY/S 125-500 models have been designed for solid fuel from 116 to 456 kW. These boilers are user-friendly and provide high efficiency. Electronic control panel allows to control the operation of the boiler at all stages.
Fuel adjustment: Fuel adjustment is made by means of two buttons on the control panel which set feeding and waiting time.
Digital control panel: EKY/S boilers are operated with digital control panel which provides precise and efficient control and contributes to longer operation life cycle of the boiler
Safety: The boiler's water temperature is set with the thermostat on the digital control panel. If for any reason the water temperature rises to 100 ° C, limit thermostat is activated and fan operation is stopped. The boiler has to be restarted manually.
Flue flap: EKY/S boilers are equipped with flue flap in order to achieve fuel saving for high draught flues. It can be adjusted easily by the user due to its position visible from outside.
Fuel warning: The superiority of EKY/S boilers is to prevent unnecessary operation of the fan indicating burnout on the control panel when out-of-fuel.
High Technology Burning Chamber
The new prismatic 4 pass boilers, have been designed with round shape oven in order to increase the burning effieciency and to provide equal fuel distribution. This round shape oven provides aerodynamic air distrubution, fuel progress angle and burning distance which was not ensured at previous oven type. With new type oven the burning efficiency will increase so that there won’t be any unburned fuel leaves on the oven which means that fuel costs will be decreased.
ww
w.te
rmod
inam
ik.c
om.tr
15
116 kW - 456 kW
3 BARSolid Fuel4-pass Construction
Manual Loading
ww
w.te
rmod
inam
ik.c
om.tr
16
A
FE150 mm
CD
" "
B
G
ØH
HIGH PERFORMANCEWITH FOUR PASS DESIGN
2 1/2˝2 1/2˝2 1/2˝2 1/2˝
3˝3˝3˝4˝4˝4˝
1 1/2˝1 1/2˝1 1/2˝1 1/2˝1 1/2˝1 1/2˝1 1/2˝
2˝2˝2˝
3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝
3
3
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
3
3
3
3
3
3
3
3
CH InputOutput
BoilerExpansion
Tank
BoilerDischarge
OperatingPressure
(bar)
TestPressure
(bar)
490
920
550
1260
690
1490
610
1350
750
1710
WaterVolume
(L)
1220
2470
1420
3150
1660
3950
1530
3430
2120
4220
Weight(kg)
Outlet
1340 1350
1640 1550
1340 1350
1840 1810
1340 1350
1840 1810
1340 1350
1840 1810
1640 1550
1840 1810
756 378 350886 443 350
503 350593 350544 400689 400697 500757 500842 500980 500
1495
1996
2670 10101186
3181 12221684
1315
1826
2490 10101006
3011 12221514
1195
1706
2370 1010
2891 12221394
1065
1690
2240 1010
2875 108113781400
2272
2585 10811088
3457 12221960
A(mm)
B(mm)
C(mm)
D(mm)
G(mm)
E (mm)
F (mm)
H (mm)Model
EKY 125
EKY 300
116
276
138
321
165
369
186
423
234
456
EKY 150
EKY 350
EKY 175
EKY 400
EKY 200
EKY 450
EKY 250
EKY 500
Capacity(Pellet)
Kw
We are reserved the right to make changes in dimensions and appearance.
EKY cylindrical boilers have been engineered in 10 different models with heating capacity range from 145 kW to 581 kW. 4-pass construction allows to benefit from high efficiency and economy of the fuel required for the buring of the boiler.
Advantages of 4-pass boilers due to the increased heat transfer surface compared to 3-pass boilers:
Higher efficiency.Longer boiler's life cycle due to low thermal loads.
Eco-design with low flue gas emission.Longer burning time.
Designed for burning of solid fuels,Resistant to high temperature steel and stable to physical shocks cast iron ensure problem-free operation even under the heaviest conditions,Stainless steel turbulators placed in the flue pipes support heat transfer, decreases fuel consumption and also contributes to long-life of the boiler preventing condensation in the flue pipes,Exterior sheets are painted with epoxy paint against corrosion. Heat losses are minimized with glass wool insulation applied to the boiler's body and coating sheets,Safety operation is ensured with hydrometer, limit thermostat, setting thermostat and thermometer.
ww
w.te
rmod
inam
ik.c
om.tr
17
116 kW - 912 kW
5, 6, 8 BARSolid Fuel4-pass Construction
Manual Loading
ww
w.te
rmod
inam
ik.c
om.tr
18
A
FE150 mm
CD
" "
B
G
ØH
(bar) (bar)
5 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 12
490550610690750920126013501490171017801910235024902660279039204500
WaterVolume Weight
(L)
Capacity(pellet)
CH InletOutlet
BoilerDischarge
BoilerExpansion
Tank
OperatingPressure
TestPressure
Outlet
HIGH PERFORMANCEWITH FOUR PASS DESIGN
EKY cylindrical boilers have been engineered in 18 different models with heating capacity range from 145 kW to 1162 kW. 4-pass construction allows to benefit from high efficiency and economy of the fuel required for the buring of the boiler.
Resistant to high temperature steel and stable to physical shocks cast iron ensure problem-free operation even under the heaviest conditions,Stainless steel turbulators placed in the flue pipes support heat transfer, decreases fuel consumption and also contributes to long-life of the boiler preventing condensation in the flue pipes,Exterior sheets are painted with epoxy paint against corrosion. Heat losses are minimized with glass wool insulation applied to the boiler's body and coating sheets,Safety operation is ensured with hydrometer, limit thermostat, setting thermostat and thermometer,The superiority of EKY boilers is to prevent unnecessary operation of the fan indicating burnout on the control panel when out-of-fuel.
Higher efficiency.Longer boiler's life cycle due to low thermal loads.
Eco-design with low flue gas emission.Longer burning time.
Advantages of 4-pass boilers due to the increased heat transfer surface compared to 3-pass boilers:
We are reserved the right to make changes in dimensions and appearance.
116
276
138
321
165
369
186
423
234
456506550596632684733825912
ww
w.te
rmod
inam
ik.c
om.tr
19
116 kW - 456 kW
3 BARSolid Fuel4-pass Construction
Automatic Loading
ww
w.te
rmod
inam
ik.c
om.tr
20
AK 150 mmL
EC
D F
J (Removal distance from bunker)
M (Shaft removal distance)
" "
B
ØH
G
EKY/S 125-200
EKY/S 250-500
A
K
CE
D
J (Removal distance from Bunker)
M (Shaft removal distance)
150 mm
I
ØH
G
B
1340 1350
1640 1550
1340 1350
1840 1810
1340 1350
1840 1810
1340 1350
1840 1810
1640 1550
1840 1810
350350350350400400500500500500
1495
1996
2260 1395 1985 1010
4160 2520 3020 1222
1315
1826
2080 1395 1985 1010
3990 2350 3020 1222
1195
1706
1960 1395 1985 1010
3870 2230 3020 1222
1065
1690
1830 1395 1985 1010
3850 2210 2820 10811400
2272
3560 1920 2820 1081
4440 2795 3020 1222
A(mm)
B(mm)
C(mm)
D(mm)
G(mm)
E (mm)
F (mm)
H (mm)
130 105
240 210
170 145
240 210
240 210
240 210
240 210
240 210
240 210
240 210
BunkerCapacity
116
276
138
321
165
369
186
423
234
456
Model
EKY/S 125
EKY/S 300
EKY/S 150
EKY/S 350
EKY/S 175
EKY/S 400
EKY/S 200
EKY/S 450
EKY/S 250
EKY/S 500
Capacity(Pellet)
Kw Coal Prina
Model
EKY/S 125
EKY/S 300
EKY/S 150
EKY/S 350
EKY/S 175
EKY/S 400
EKY/S 200
EKY/S 450
EKY/S 250
EKY/S 500
378443503593544689697757842980
2965 1186
5340 1684
2965 1006
5165 1514
2965 886
5135 1394
2965 756
5120 13784930 1088
5660 1960
J (mm)
K (mm)
L (mm)
3365336533653365603562256240627064456765
(mm)
2 1/2˝2 1/2˝2 1/2˝2 1/2˝
3˝3˝3˝4˝4˝4˝
1 1/2˝1 1/2˝1 1/2˝1 1/2˝1 1/2˝1 1/2˝1 1/2˝
2˝2˝2˝
3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝3/4˝
3
3
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
3
3
3
3
3
3
3
3
CH InletOutlet
BoilerExpansion
TankBoiler
DischargeOperatingPressure
(bar)
Test Pressure
(bar)
1515,11700
1870,72126,8294035493900
4174,34563
5193,9
Weight(kg)
M
490
920
550
1260
690
1490
610
1350
750
1710
Water Volume
(L)Outlet
HIGH PERFORMANCEWITH FOUR PASS DESIGN
EKY/S cylindrical boilers have been engineered in 10 different models with heating capacity range from 145 kW to 581 kW. 4-pass construction allows to benefit from high efficiency and economy of the fuel required for the buring of the boiler.
Advantages of 4-pass boilers due to the increased heat transfer surface compared to 3-pass boilers:
Higher efficiency.Longer boiler's life cycle due to low thermal loads.
Eco-design with low flue gas emission.Longer burning time.
Designed for burning of solid fuels,Resistant to high temperature steel and stable to physical shocks cast iron ensure problem-free operation even under the heaviest conditions,Stainless steel turbulators placed in the flue pipes support heat transfer, decreases fuel consumption and also contributes to long-life of the boiler preventing condensation in the flue pipes,
We are reserved the right to make changes in dimensions and appearance.
ww
w.te
rmod
inam
ik.c
om.tr
21
116 kW - 912 kW
5, 6, 8 BARSolid Fuel4-pass Construction
Automatic Loading
ww
w.te
rmod
inam
ik.c
om.tr
22
AK 150 mmL
EC
D F
J (Removal distance from bunker)
M (Shaft removal distance)
" "
B
ØH
G
EKY/S 125-200
EKY/S 250-1000
A
K
CE
D
J (Removal distance from bunker)
M (Shift removal distance)
150 mm
I
ØH
G
B490
920
550
1260
690
1490
610
1350
750
171017801910235024902660279039204500
WaterVolume Weight
(L)
5 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 12
5 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 12
336533653365336560356225624062706445676568657035681069307100722069307320
MCapacity(Pellet)
PelletCapacity HIGH PERFORMANCE
WITH FOUR PASS DESIGN
We are reserved the right to make changes in dimensions and appearance.
EKY/S cylindrical boilers have been engineered in 18 different models with heating capacity range from 116 kW to 912 kW. 4-pass construction allows to benefit from high efficiency and economy of the fuel required for the buring of the boiler.
Designed for burning of solid fuels,Resistant to high temperature steel and stable to physical shocks cast iron ensure problem-free operation even under the heaviest conditions,Stainless steel turbulators placed in the flue pipes support heat transfer, decreases fuel consumption and also contributes to long-life of the boiler preventing condensation in the flue pipes,
Higher efficiency.Longer boiler's life cycle due to low thermal loads.
Eco-design with low flue gas emission.Longer burning time.
Advantages of 4-pass boilers due to the increased heat transfer surface compared to 3-pass boilers:
OperatingPressure
(bar)
TestPressure
(bar)
CH InletOutlet
BoilerDischarge
BoilerExpansion
TankOutlet
116
276
138
321
165
369
186
423
234
456506550596632684733825912
ww
w.te
rmod
inam
ik.c
om.tr
23
116 kW - 912 kW
5, 6, 8 BARSolid Fuel4-pass Construction
Automatic Loading
ROUND OVEN
ww
w.te
rmod
inam
ik.c
om.tr
24
HIGH PERFORMANCEWITH FOUR PASS DESIGN
We are reserved the right to make changes in dimensions and appearance.
EKY/S cylindrical boilers have been engineered in 18 different models with heating capacity range from 116 kW to 912 kW. 4-pass construction allows to benefit from high efficiency and economy of the fuel required for the buring of the boiler.
Coal, pellet, olive core and nut shell can be used as fuel in the boiler ,because of using the round firebox. There is no necessity to pour concrete around the round firebox because of the round firebox technology.Stainless steel turbulators placed in the flue pipes support heat transfer, decreases fuel consumption and also contributes to long-life of the boiler preventing condensation in the flue pipes.Insulation plates are used for insulation and are used on the rear cover. These insulation plates increases the boiler’s efficiency.
Higher efficiency.Longer boiler's life cycle due to low thermal loads.
Eco-design with low flue gas emission.Longer burning time.
Advantages of 4-pass boilers due to the increased heat transfer surface compared to 3-pass boilers:
3784435035935441655
1350 106712001320150014001690171018302000227623762546231524352610271524152810
1830 1585 21202120212021202430243026352630263026302630263028002800280028003110
3110
600600600600710710760760760760760760845845845845752
752
36253625362536254100410044104400440044004400440046254625
200021202290240021002490
462546255100
5100
15801580158018951895210020952095209520952095226022602260226025702570
19702090227021702460249026102780305031503320309032103380349031903580
13501350135015501550181018101810181018101810203520352035203522902290
1655185518551855185518551855205020502050205023702370
68969775784298010301115100010601145120010501245
490
920
550
1260
690
1490
610
1350
750
171017801910235024902660279039204500
WaterVolume Weight
(L)
5 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 12
5 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 125 6 8 9 12
A
C
G
H
K 150 mm
DF
EJ (Shaft Removal Distance)
B
L
Capacity(Pellet)
kW
Bunker Capacity
OperatingPressure
(bar)
TestPressure
(bar)
CH Input-Output
BoilerDischarge
BoilerExpansion
Tank Outputpellet
116
276
138
321
165
369
186
423
234
456506550596632684733825912
ww
w.te
rmod
inam
ik.c
om.tr
25
Elegant DesignHigh Efficiency
Operating Test
Panel surfaces, water channels and convectors of Termodinamik Panel Radiators are designed to ensure maximum heating.Panel Radiators occupy less space and has a beautiful appearance thanks to elegant design. For having high thermal power and efficiency, they heat the environment in the shortest time and provides fuel saving.Termodinamik panel radiators, with their height 300-400-500-600-900 mm and length from 400 mm to 3000 mm increasing in 100 mm ranges, ensure to choose the radiators with the most appropriate dimensions for the heating need and decorative design of the environment.For the purpose of preventing from shocks and healthy transportation, Termodinamik Panel Radiators are packed in carton box as supported with balloon and shrink nylon.
.
ww
w.te
rmod
inam
ik.c
om.tr
26
Min 100
Min 100
Min 100
Min 100
INSTALLATION TABLE
HEIGHTH (mm)
CONSOLEWIDTHN (mm)
MENSOL DISTANCE
C (mm)
MENSOL TOP AND BOTTOMDISTANCE TO PANEL
D-E (mm)
MENSOLWIDTHF (mm)
MENSOLWIDTHF (mm)
MONTAGEHEIGHTP(mm)
400 33 - 45193 91 25 50
600 33 - 45318 128.5 25 50
300
.
33 - 4593 91 25 50
500 33 - 45218 128.5 25 50
900 33 - 45618 128.5 25 50 Min 100
HIGHH (mm)TYPE 22 PKKP
DEPTHK (mm)
WATERVOLUME
L
WEIGHTkg
LENGTHL (mm)
AXISRANGEA (mm)
HIGH OFCONVECTOR
B (mm)
400 72 4 20.38 400 - 3000350 300
600 72 6 30.62 400 - 3000550 500
300
TECHNICAL SPECIFICATIONS
72 3 15.50 400 - 3000250 200
500 72 5 25.23 400 - 3000450 400
900 72 9 45.13 400 - 3000850 800
We are reserved the right to make changes in dimensions and appearance.