ebo 8 aquifer

Upload: 13670319

Post on 18-Oct-2015

80 views

Category:

Documents


8 download

DESCRIPTION

Eclipse 100 Describtion

TRANSCRIPT

  • 5/28/2018 EBO 8 Aquifer

    1/9

    Aquifer Modelling

    This slide does not appear in the manual

  • 5/28/2018 EBO 8 Aquifer

    2/9

    SIS Training

    2

    Aquifer Modeling

    ECLIPSE Blackoil provides these aquifer options:

    Numerical Aquifer

    Analytical Aquifer

    Carter-Tracy aquifer

    Fetkovich aquifer

    Flux Aquifer

    Grid Cell Aquifer

  • 5/28/2018 EBO 8 Aquifer

    3/9

    SIS Training

    3

    Nominate grid cells below the OW contact (AQUNUM)

    Attach the aquifer to the reservoir using AQUCONLeave a row of water cells between the aquifer & oil zone

    Oil Zone

    No Flow

    Aquifer Cells

    GRID

    AQUNUM

    --Aq# I J K Area Length

    1 3 7 1 1E2 1E2 0.3 /

    1 4 7 1 1E4 1E3 0.3 /

    1 5 7 1 1E6 1E4 0.3 /

    AQUCON

    --Aq# I1 I2 J1 J2 K1 K2 Face

    1 1 1 2 6 1 1 I- /

    Numerical Aquifer

  • 5/28/2018 EBO 8 Aquifer

    4/9

    SIS Training

    4

    Fetkovich Aquifers

    Fetkovich aquifers are based on a pseudo-steady stateproductivity index and material balance between aquifer

    pressure and cumulative influxThey are best suited for smaller aquifers which mayapproach psuedo steady state quickly

    In the Solution Section:

    Set up lists of aquifers AQUALIST

    Define the aquifer with AQUFETP Connect the aquifer with AQUANCON

  • 5/28/2018 EBO 8 Aquifer

    5/9

    SIS Training

    5

    Carter-Tracy Aquifers

    Carter-Tracy aquifers use tables of dimensionless time tdversus dimensionless pressure Pd(td)to determine the influx

    Carter-Tracy approximates a fully transient model

    In the Solution Section:

    Set up lists of aquifers AQUALIST

    Define the aquifer with AQUCT

    Define pressure response with AQUTAB

    Connect the aquifer with AQUANCON

  • 5/28/2018 EBO 8 Aquifer

    6/9

    SIS Training

    6

    Flux Aquifers

    The flux rate is specified directly by the user:

    It may be negative, representing flux out of the reservoir

    The flux rate may be modified in the Schedule Section

    In the Solution section

    Set up lists of aquifers AQUALIST

    Specify the aquifer using AQUFLUX

    Attach the aquifer using AQUANCON

    iiaai mAFQ =

    Fa is the flux

    Ai the area of the connecting cell block

    mi is an aquifer influx multiplier

  • 5/28/2018 EBO 8 Aquifer

    7/9

    SIS Training

    7

    Grid Cell Aquifer

    Simulation model extends over the water zone

    No extra keywords necessary

  • 5/28/2018 EBO 8 Aquifer

    8/9

    SIS Training

    8

    Output Controls

    Summary Quantities

    Analytic aquifers

    AAQR, AAQT, AAQP

    Numerical aquifers

    ANQR, ANQT, ANQP

    Print file data

    RPTGRID, RPTSCHED, RPTSOL

  • 5/28/2018 EBO 8 Aquifer

    9/9

    SIS Training

    9This slide does not appear in the manual