11
Cryogenic Carbon Capture Brief summary report Nov. 2015 Sahand Faraji Berk Celiktas

Upload: sahand-faraji

Post on 19-Feb-2016

218 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: first short report.pptx

Cryogenic Carbon Capture

Brief summary reportNov. 2015

Sahand FarajiBerk Celiktas

Page 2: first short report.pptx

GC Calibration78 Experiment Have been carried out

Standard Gas Cylinder( around 40 exp)

• Real Gas Percentage(±2%):CO2: 74.48%; O2: 17.65%; N2: 7.88%

• Experiment results:CO2: 80; O2: 14; N2: 6

Questions and suggestion:• According to approximation:

O2, N2 are acceptable But CO2 is not!

• Accept this Calibration (which work for us)

• Buying new standard cylinder• Changing method which is not recommended

Page 3: first short report.pptx

GC Calibration78 Experiment Have been carried out

Entrance Mix gas( around 40 exp.)

• The exact gases amount in mixture are obtained, BUT:

Questions and suggestion:• The time of sweeping is changed

variously from 3min to 40min (Based on the mixture and the flowrate)

• →Vacuum pump could solve the major part of this problem.Detector’s solid substance need to be sweeping. So the time consumption is inescapable.

Page 4: first short report.pptx

Cryogenic Carbon Capture2 Experiment Have been carried out

The experiment took about 1hour.This time consume for:• Chiller cooling• Compressor

pressurizing

Pros:• No leakage have been

recorded in the system.• No water have been

observed after the third condenser.

• Process controller system correctly worked

• Steam generator worked well in the system

Cons and bottlenecks:• Liquid CO2 have been

obtained BUT the separation faced a problem.

• The compressor oil vomiting have been happened in both case.

Page 5: first short report.pptx

Cons and bottlenecks:

• Presence of CO2 is completely visible in the purge line:(The intense temperature drop is an evidence as well as GC recordings)

Page 6: first short report.pptx

Cons and bottlenecks (Bottleneck):The milestone picture

Page 7: first short report.pptx

Cons and bottlenecks (Bottleneck):

The Milestone Picture:• The left gauge presented the outlet flow pressure, this is not

demanded!!• The outlet pressure must be equal to the liquefaction

conditions(P>80bar)• After a while from the beginning of the experiment this pressure is

applied to the first drum and that is the reason of compressor oil vomiting!

• What is the difference between CO2 cylinder and ours?

Page 8: first short report.pptx
Page 9: first short report.pptx
Page 10: first short report.pptx

Larry Baxter research:

Page 11: first short report.pptx

Extra Suggestion:

Starting to learn Aspen Hysys for modelling the system required.