low voltage switchgear product lineup

29
1 MITSUBISHI ELECTRIC Low Voltage Switchgear Line-Up

Upload: andrew-maverick

Post on 23-Oct-2015

31 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: Low Voltage Switchgear Product Lineup

1

MITSUBISHI ELECTRIC

Low Voltage Switchgear Line-Up

Page 2: Low Voltage Switchgear Product Lineup
Page 3: Low Voltage Switchgear Product Lineup

3

Line-up of AE-SW

•Line-up of MITSUBISHI ACB

•Connections•Conform to Global standard

•Others

Page 4: Low Voltage Switchgear Product Lineup

4

Frame 630AF 1000AF 1250AF 1600AF 2000AF 2500AF 3200AF 4000AF 5000AF 6300AF

AE-SW

Series

AE630AE630AE630AE630----

SSSSSSSS

AE1000AE1000AE1000AE1000----

SSSSSSSS

AE1250AE1250AE1250AE1250----

SSSSSSSS

AE1600AE1600AE1600AE1600----

SSSSSSSS

AE2000AE2000AE2000AE2000----

SSSSSSSS

AE2500AE2500AE2500AE2500----

SSSSSSSS

AE3200AE3200AE3200AE3200----

SSSSSSSS

AE4000AE4000AE4000AE4000----

SSASSASSASSA

AE4000AE4000AE4000AE4000

----SWSWSWSW

AE5000AE5000AE5000AE5000

----SWSWSWSW

AE6300AE6300AE6300AE6300

----SWSWSWSW

AE-SH

SeriesAE630AE630AE630AE630

----SHSHSHSH

AE1000AE1000AE1000AE1000

----SHSHSHSH

AE1250AE1250AE1250AE1250

----SHSHSHSH

AE1600AE1600AE1600AE1600

----SHSHSHSH

AE2000AE2000AE2000AE2000

----SHSHSHSH

AE2500AE2500AE2500AE2500

----SHSHSHSH

AE3200AE3200AE3200AE3200

----SHSHSHSH

Line-up of MITSUBISHI ACB

AE2000 AE2000 AE2000 AE2000

----SWASWASWASWA

AE1600 AE1600 AE1600 AE1600

----SWSWSWSW

AE1250 AE1250 AE1250 AE1250

----SWSWSWSW

AE1000 AE1000 AE1000 AE1000

----SWSWSWSW

AE630 AE630 AE630 AE630

----SWSWSWSW

AE4000AE4000AE4000AE4000

----SWASWASWASWA

AE3200 AE3200 AE3200 AE3200

----SWSWSWSW

AE2500 AE2500 AE2500 AE2500

----SWSWSWSW

AE2000 AE2000 AE2000 AE2000

----SWSWSWSW

Page 5: Low Voltage Switchgear Product Lineup

5

4pole 50% neutral

(4P HN)

4pole 100% neutral

(4P FN)

Retrofitted Previous model +130mm

*Dimensions are

in case of Draw-out type

1005 mm 1135 mm

AE4000-SW~~~~AE6300-SW

Page 6: Low Voltage Switchgear Product Lineup

6

Connections

Fixed

Drawout

Connections

Type

Horizontal

(Standard)

Vertical

(VT)

Front

(FT)

Fixed (FIX) -

Drawout (DR)

Connections

Type

Vertical terminal

adapter (VTA)

Front terminal

adapter (FTA)

Fixed (FIX)

Drawout (DR)

Page 7: Low Voltage Switchgear Product Lineup

7

AE630SW

-AE1600SW

AE2000/

4000-SWA

AE2000SW

-AE3200SW

AE4000SW

- AE6300SW

Fixed type

(FIX)

Horizontal ● - ● -

FIX-VT - ● - ●

FIX-VTA ○ - ○ -

FIX-FTA ○ - ○ -

Drawout

(DR)

Horizontal ● - ● -

DR-VT ○ ● ○ ●

DR-FT ○ - ○ -

DR-VTA ○ - ○ -

DR-FTA ○ - ○ -

●:standard ○:optional

Connections

Page 8: Low Voltage Switchgear Product Lineup

8

Standard

International standard:IEC60947-1,,,,2

Other overseas standard: EN(Europe), GB(China)

Japanese standard: JIS C8201-2 / C8372

3rd Party Certification

CCC (China), TPC (Taiwan)

LR,,,,GL,,,,BV, DNV, ABS,,,,CCS ,,,,NK

Conform to Global standardfor AE630~~~~3200SW, 2000SWA,4000SWA

Safety Certification and Marine Approval

ASTA (AE630-SW~3200-SW,2000-SWA,4000-SWA)

KEMA (AE4000-SW~6300-SW)

Page 9: Low Voltage Switchgear Product Lineup

9

Electronic Trip Relay

•Electronic Trip Relay

•Network

Page 10: Low Voltage Switchgear Product Lineup

10

Network

CC-Link

(BIF-CC)

CC-Link

(BIF-CC)PROFIBUS-DP

(BIF-PR)

PROFIBUS-DP

(BIF-PR)Modbus:RS-485

(BIF-MD)

Modbus:RS-485

(BIF-MD)

I/O unit

(BIF-CON)

I/O unit

(BIF-CON)

-Option-

*EX1 is needed for BIF

Main networks for ACB

Drawout position switch

(BIF-CL)

Drawout position switch

(BIF-CL)

Page 11: Low Voltage Switchgear Product Lineup

11

Factory automationFactory automationFactory automationFactory automation

((((CCCCCCCC----Link, PROFIBUS)Link, PROFIBUS)Link, PROFIBUS)Link, PROFIBUS)

Interface Interface Interface Interface

unitunitunitunit

PLC : masterPLC : masterPLC : masterPLC : master

Interface Interface Interface Interface

unitunitunitunit

Interface Interface Interface Interface

unitunitunitunit

Interface Interface Interface Interface

unitunitunitunit

PC : masterPC : masterPC : masterPC : master

Converter (RSConverter (RSConverter (RSConverter (RS----232C/RS232C/RS232C/RS232C/RS----485)485)485)485)

Distributed automationDistributed automationDistributed automationDistributed automation

(Modbus)(Modbus)(Modbus)(Modbus)

NetworkHigh-performance

BIF can be installed later.

Page 12: Low Voltage Switchgear Product Lineup

Accessories

Page 13: Low Voltage Switchgear Product Lineup

MITSUBISHIELECTRONIC MULTI-MEASURING INSTRUMENT

ME96NSR

Small & Flexible

Page 14: Low Voltage Switchgear Product Lineup

1. Lineup

Model Name Transmission

ME96NSR -

ME96NSR-MB ModBus Communication

Model NameAnalog

Output

Pulse

Output

Contact

Input

Contact

Output

Transmission

Function

ME-4201-NS96 4 2 - 1 -

ME-0040C-NS96 - - 4 - CC-Link

ME-0052-NS96 - - 5 2 -

●●Basic Device

●●Optional Plug-in Module

Page 15: Low Voltage Switchgear Product Lineup

2. Features◆◆◆◆Variety of Measuring Items

◆◆◆◆3P4W/3P3W Common Use

◆◆◆◆Variety of Display Functions

◆◆◆◆VT, CT Set Freely

A,DA,V,W,var,VA,PF,Hz,Wh,varh,HI,HV

96 mm

◆◆◆◆DIN 96××××96mm Size

Large Bar Graph + Tri-level Digital Display

◆◆◆◆Option Module Plug-in Add-on Type

No need to specify phase-wire when ordering

◆◆◆◆Instrument Rated Current 5A/1A Common Use

◆◆◆◆Remote Input/Output Function

Page 16: Low Voltage Switchgear Product Lineup

◆Variety of Display Functions

●●All Phase

Simultaneous Display

●●4 Measuring Elements

Simultaneous Display

3. Functions

Average Voltage

Voltage

Current

Power

Factor

Electricity

Page 17: Low Voltage Switchgear Product Lineup

●●Special Display Pattern

<<<<Functions Available>>>>

◆◆◆◆Keep the display unchanged

Keep the display unchanged when even when the DISPLAY

button is pushed

⇒⇒⇒⇒ Please set only 1 display

◆◆◆◆Use ME96NSR instead of electric energy meter by displaying

electric power

Upper::::Select from A,V,W,var,VA,PF,Hz

Middle::::Select from A,V,W,var,VA,PF,Hz

Lower::::Select from A,V,W,var,VA,PF,Hz,Wh,varh

Maximum of 4 displays are settable

Page 18: Low Voltage Switchgear Product Lineup

●●●●Maximum/Minimum

Value Display

●●●●Alarm Indicator

・・・・Displays Alarm Indicator in bar graph

・・・・Enable to grasp the percentage against

the Alarm Indicator instantly

●●●●Cyclic Display

・・・・Automatically changes display every 5 seconds

・・・・Cyclic Display continues even after the power

is turned ON/OFFMin. Value

Max. Value

Current Value

Min. Value

Max. Value

Alarm Indicator

Page 19: Low Voltage Switchgear Product Lineup

◆Remote Input/Output Function

・・・・ME-0040C-NS96

Contact Input: 4 points

◆Test Function

Even during a setup of a facility, where no input current/voltage is found,

analog output, pulse output, alarm output, and communication data is replied.

This allows for easy checking of system’s wiring and monitoring program.

・・・・ME-0052-NS96

Contact Input: 5 points

Contact Output: 2 points

・・・・Latch Function (Over 30ms)

Page 20: Low Voltage Switchgear Product Lineup

4. SpecificationsMeasuring Items 3P4W 3P3W

Current (A) A1,A2,A3,AN,AAVG A1,A2,A3,AAVG

Current Demand (DA) DA1,DA2,DA3,DAN,DAAVG DA1,DA2,DA3,DAAVG

Voltage (V)V12,V23,V31,VLLAVG or

V1N,V2N,V3N,VLNAVG

V12,V23,V31,VLLAVG

Active Power (W) ∑∑∑∑W,W1,W2,W3 ∑∑∑∑W

Reactive Power (var) ∑∑∑∑var,var1,var2,var3 ∑∑∑∑var

Apparent Power (VA) ∑∑∑∑VA,VA1,VA2,VA3 ――――

Frequency (Hz) Hz

Power Factor (PF) ∑∑∑∑PF,PF1,PF2,PF3 ∑∑∑∑PF

Active Energy (Wh) Imported, Exported

Reactive Energy (varh) Imported Lead, Imported Lag, Exported Lead, Exported Lag

Harmonics Current (HI)HI1,HI2,HI3,HIN HI1,HI2,HI3

THD, h1, ・・・,・・・,・・・,・・・,h13 RMS Value and Distortion Ratio

Harmonics Voltage (HV)HV1N,HV2N,HV3N HV12,HV23

THD, h1, ・・・,・・・,・・・,・・・,h13 RMS Value and Distortion Ratio

Page 21: Low Voltage Switchgear Product Lineup

Measuring ItemsDisplay Analog Output, Pulse Output

AC5A AC1A AC5A AC1A

Current (A)

0.5%%%% 1.0%%%% 0.5%%%% 1.0%%%%

Current Demand (DA)

Voltage (V)

Active Power (W)

Reactive Power (var)

Apparent Power (VA)

Frequency (Hz)

Power Factor (PF) 2.0%%%% 3.0%%%% 2.0%%%% 3.0%%%%

Active Energy (Wh) 1.0%%%% 2.0%%%% 1.0%%%% 2.0%%%%

Reactive Energy (varh) 2.0%%%% 2.0%%%% 2.0%%%% 2.0%%%%

Harmonics Current (HI) 2.5%%%%2.5%%%%

(RMS Value, 0----Rating××××60%%%%)

Harmonics Voltage (HV) 2.5%%%%2.5%%%%

(Total Distortion Ratio, 0----20%%%%)

●●●●Measuring Accuracy

Page 22: Low Voltage Switchgear Product Lineup

3P4W (Phase Voltage (L-N)/Line Voltage (L-L))

3P3W (Line Voltage)

63.5V/110V, 100V/173V, 110V/190V

220V/380V, 240V/415V, 254V/440V

277V/480V

110V,220V

●●●●Direct Input

●●●●VT Primary Voltage, CT Primary Voltage

・・・・VT::::60V~~~~750kV

・・・・CT::::5A~~~~30kA

●●●●Power Failure Compensation

Setting Value, Max./Min. Value, Active Energy, Reactive Energy is memorized

●●●●CE Marking

・・・・EMC : EN61326-1/2006

・・・・Safety : EN61010-1/2001

Page 23: Low Voltage Switchgear Product Lineup

30(32)AF

63AF

125AF

160AF

250AF

400AF

630AF

800AF

1000AF

1250AF

1600AF

C series(Economy)

NF30-CS

NF63-CW

NF125-CW

NF250-CW

NF400-CW

NF630-CW

NF800-CEW

NF32-SW

NF63-SW

NF125-SW

NF160-SW

NF250-SW

NF400-SW

NF630-SW

NF125-SGW

NF160-SGW

NF250-SGW

NF400-SEW

NF630-SEW

NF800-SEW

NF1000-SEW

NF1250-SEW

NF1600-SEW

NF63-HW

NF125-HW

NF160-HW

NF250-HW

NF125-HGW

NF160-HGW

NF250-HGW

NF400-HEW

NF630-HEW

NF800-HEW

NF125-RGW

NF250-RGW

NF125-UGW

NF250-UGW

NF400-UEW

NF800-UEW

S series(Standard)

H series(High)

U series(Ultra)

MCCB Line Up

Page 24: Low Voltage Switchgear Product Lineup

30(32)AF

63AF

125AF

160AF

250AF

400AF

630AF

800AF

1000AF

1250AF

1600AF

C series(Economy)

NV30-CS

NV63-CW

NV125-CW

NV250-CW

NV400-CW

NV630-CW

NV32-SW

NV63-SW

NV125-SW

NV250-SW

NV400-SW

NV630-SW

NV250-SEW

NV400-SEW

NV630-SEW

NV800-SEW

NV63-HW

NV125-HW

NV250-HW

NF250-HEW

NV400-HEW

NV630-HEW

NV800-HEW

U series(Ultra)

NV125-RW

NV250-RW

NV400-REW

S series(Standard)

H series(High)

ELCB Line Up

Page 25: Low Voltage Switchgear Product Lineup

・・・・Downsizing of 630AF (same as 400AF)Downsizing of 630AF (same as 400AF)Downsizing of 630AF (same as 400AF)Downsizing of 630AF (same as 400AF)

Improved 400-800AF

Previous New

Volume60%

3-pole:available up to 400VDC4-pole:available up to 500VDC

・AC/DC common use (NF400-CW/SW,NF630-CW/SW)

Page 26: Low Voltage Switchgear Product Lineup

・Improved Breaking capacity at 400/415VACNF400-SEW, NF630-SW/SEW, NF800-SEWNV400-SEW, NV630-SW/SEW, NV800-SEW

Improved 400-800AF (2)

Ics/Icu45/45kA

Ics/Icu50/50kA

・Improved Breaking capacity at 690VACNF400-HEW, NF630-HEWNV400-HEW, NV630-HEW

Ics/Icu15/15kA

Ics/Icu35/18kA

PreviousNew

Previous New

Page 27: Low Voltage Switchgear Product Lineup

Conform to Global standard

・International standard: IEC60947-2

・European standard : EN 60947-2

・Chinese standard : GB14048.2

・Japanese standard : JIS C 8201-2-1/-2

・3rd Party Certification : ASTA

・Others : CE marking, CCC

・Shipping approvals : LR,BV, DNV, ABS,NK,GL

Page 28: Low Voltage Switchgear Product Lineup

NF400-SEP with MDU

・MDU (Measuring Display Unit) with 250-800AF・MDUMDU measures circuit condition data:

・Measuring data can be transmitted to PLCthrough CC-Link

and display them as digits.

MDU Breaker for managing energy

current voltage

power energy

harmonic wave current

power factor

・Tripped current are memorized in MDU

Page 29: Low Voltage Switchgear Product Lineup