techem smart system · 2018. 11. 8. · techem smart system is based on the technology of the tried...

2
DATASHEET Devices and Service Techem Smart System Product description Techem Smart System is based on the technology of the tried and tested Techem radio frequency (RF) system. The remote reading system provides you with access to a wide range of general and monitoring services. The prerequisite for this is to equip with the current Techem RF reading device generation (data IIl). The RF reading devices transmittheir data regularly to a data collector. This stores and manages the consumption data and device status information and transmits them to the master data collector. In this way, the complete consumption values and device information of the object's RF reading devices are contained in the master data collector. The consumption data (due dates and interme-diate daily values) and the device states are regularly transmitted to the Techem data centre through a secured connection via GPRS. They are further processed here. Techem Smart System is the basis for innovative value-added services: Device Monitoring – continuous, pro-active monitoring of the reading devicesand timely replacement in case of defects. Reading Value Display - Reading values can be retrieved online at any time by you and your residents – retrospectively and exact to the day. Energy and Water Monitoring – for more clarity regarding consumption – based on regularly updated values. adapterm – using this energy savings system, save an average of 10% of heating energy. 2 1 1 1 1 3 4 5 7 9 9 6 8 Master data collector Data collector 1-n via GPRS Billing Device Monitoring Reading Value Display adapterm Meter reading devices send their values to the data collector via radio transmission The data collector saves the consumption values transmitted from the measuring devices and sends them to the master data collector The master data collector saves consumption values and device status information from all devices This data is transmitted by GPRS to the Techem computer centre Prompt billing for your properties Device Monitoring: Permanent monitoring of your end devices Reading Value Display : Reading values can be retrieved online at any time by you and your residents – retrospectively and exact to the day. Techem Monitoring: Analysis of energy and water consumption of your properties adapterm – the Techem energy savings system Techem Monitoring

Upload: others

Post on 31-Jul-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Techem Smart System · 2018. 11. 8. · Techem Smart System is based on the technology of the tried and tested Techem radio frequency (RF) system. The remote reading system provides

DATASHEET

Devices and Service

Techem Smart System

Product descriptionTechem Smart System is based on the technology of the tried and tested Techem radio frequency(RF) system. The remote reading system provides you with access to a wide range of general andmonitoring services. The prerequisite for this is to equip with the current Techem RF reading devicegeneration (data IIl). The RF reading devices transmittheir data regularly to a data collector. Thisstores and manages the consumption data and device status information and transmits them to themaster data collector. In this way, the complete consumption values and device information of theobject's RF reading devices are contained in the master data collector. The consumption data (duedates and interme-diate daily values) and the device states are regularly transmitted to the Techemdata centre through a secured connection via GPRS. They are further processed here.

Techem Smart System is the basis for innovative value-added services:• Device Monitoring – continuous, pro-active monitoring of the reading devicesand timely

replacement in case of defects.• Reading Value Display - Reading values can be retrieved online at any time by you and your

residents – retrospectively and exact to the day.• Energy and Water Monitoring – for more clarity regarding consumption – based on regularly

updated values.• adapterm – using this energy savings system, save an average of 10% of heating energy.

2

1

1

1

1

3

4

5

7

9

9

6

8

Master datacollector

Data collector 1-n

via GPRS

Billing

Device Monitoring

Reading Value Display

adapterm

Meter reading devices send their values tothe data collector via radio transmission

The data collector saves the consumptionvalues transmitted from the measuringdevices and sends them to the masterdata collector

The master data collector savesconsumption values and device statusinformation from all devices

This data is transmitted by GPRS to theTechem computer centre

Prompt billing for your properties

Device Monitoring: Permanent monitoringof your end devices

Reading Value Display : Reading valuescan be retrieved online at any time by youand your residents – retrospectively andexact to the day.

Techem Monitoring: Analysis of energyand water consumption of your properties

adapterm – the Techem energy savingssystem

Techem Monitoring

Page 2: Techem Smart System · 2018. 11. 8. · Techem Smart System is based on the technology of the tried and tested Techem radio frequency (RF) system. The remote reading system provides

Performance features• Each property can be fitted with the Techem Smart System.• Properties already fitted with data III devices can easily be retrofitted with the Techem

Smart System without having to enter the apartment.• Battery-operated data collectors avoid the need for electricians and therefore reduce the

effort required for installation – low installation costs.• Clustering of objects with up to 2,000 end devices or 60 data collectors (incl. master data

collector) possible – low installation costs.• Reduction in number of data collectors required due to high ranges – low installation

costs.• Maximum billing quality – the consumption data is taken over automatically, right up to

the billing system.• Low administration requirements – no follow-up appointments and estimations required

due to the absence of tenants.• Less effort required when tenant changes – intermediate unit readingscan be made at

any time.• Reduced downtimes – defective devices are detected and replaced early (device

monitoring).• Timely billing – thanks to automated data transfer.• Prepared for Smart Metering – compliant to the Open Metering Specification (including

Wireless M-Bus, EN 13757-4).

Battery-operated data collectorThe battery-operated data collector saves the consumption values and device status infor-mation which are transferred to it at regular intervals by the reading devices allocated to it.It is fitted with an integrated transmitter and receiver module to receive the consumptiondata and for communication between the data collectors. All data is transferred to themaster data collector.

Master data collectorThe mains-operated master data collector saves all consumption values and device statusinformation across its entire RF network, which is comprised of reading devices and datacollectors. Up to 2000 RF reading devices can be managed in one RF network coveringseveral properties with up to 60 data collectors in total, including the master data collector.It saves the consumption data of each reading device in its network-failsafe, non-volatilememory. Additionally, the master data collector is also responsible for communication withthe Techem data centre. This is carried out by means of an integrated GPRS modem thatestablishes a secure IP-VPN connection.

Err

ors

and

tech

nica

l cha

nges

exc

epte

d •

8423

8 (2

8.10

.201

1)

Data collector(battery-operated)

Master data collector(mains-operated)Technical data Data collector Master data collector

ConformityConformity

Dimensions

Transmitting powerTransmitting power

Type of protection

Power supplyPower supply

Transmission frequency

Service interfaceService interface

Error detection

RF conformityRF conformity

CE

Approx. 220 x 160 x 45 mm (H x W x D)

Max. 250 mW

IP 44

Battery (10 years + reserve)

868 MHz

Optical

Using CRC

Compliant with R&TTE guideline

CE

Approx. 220 x 160 x 45 mm (H x W x D)

Max. 250 mW

IP 21

100–240 V AC, 50–60 Hz

868 MHz

Optical

Using CRC

Compliant with R&TTE guideline

Techem Energy Services GmbHHead office: Hauptstr. 89 • 65760 Eschborn • www.techem.deTelefon: +49 (0)6196 / 522 - 0 • Fax: +49 (0)6196 / 522 - 3000 • E-mail: [email protected] offices: München, Bratislava