PRODUCT SUPPORT MANUAL
FPR-30 // Field Programmer Model No.: FPR-30 Product No.: 2902 Y1-03-0236 Rev. G
ACR Electronics, Inc. // 5757 Ravenswood Road // Fort Lauderdale // FL // 33312-6645 Tel: +1 (954) 981-3333 // Fax: +1 (954) 983-5087 // www.acrartex.com
-
About ACR Electronics ACR Electronics, www.acrartex.com, designs and manufactures a complete line of safety and survival products including EPIRBs, PLBs, AIS, SARTs, Strobe Lights, Life Jacket Lights, Search Lights and safety accessories. The quality systems of this facility have been registered by UL to the ISO 9001:2000 Series Standards. Recognized as the world leader in safety and survival technologies, ACR has provided safety equipment to the aviation and marine industries as well as to the military since 1956.
CAUTION: Before proceeding to install, test or use your new ACR Electronics product, please read this Product Support Manual in its entirety. If you have questions regarding the contents of the manual, please contact our Technical Service Department at ACR Electronics, Inc., Telephone +1 (954) 981- 3333. Please be ready to provide the technician with the page number you wish to discuss. If you have a question that is not covered in the manual, please visit our website and access the Frequently Asked Questions (FAQs) section for further information or call our Technical Service Department. The website address is www.acrartex.com. If in the future you lose this manual, you may access and print a replacement on the ACR website.
-
Table of Contents
SECTION 1 INTRODUCTION ______________________________ 3
SECTION 2 PREPARING TO INSTALL THE FPR-30 SOFTWARE ____ 4
SECTION 3 INSTALLING THE FPR-30 SOFTWARE ______________ 6
SECTION 4 PROGRAMMING A BEACON _____________________ 8
APPENDIX A- USINF AUTO-SAVED DATA _____________________ 22
APPENDIX B TIPS FOR PROGRAMMING BEACONS ____________ 23
APPENDIX C- MAKING A NEW LABEL FOR A BEACON ___________ 25
APPENDIX D RESETTING DIGITAL DISPLAY LANGUAGE (RLB-36) _ 26
APPENDIX E TECHNICAL SPECIFICATIONS- __________________ 28
APPENDIX F WARRANTY, NOTICES ________________________ 29
PLEASE READ ALL WARNINGS, CAUTIONS AND NOTES CAREFULLY
Y1-03-0236F 2
-
SECTION 1 INTRODUCTION
Congratulations and thank you for purchasing the ACR FPR-30 Programmer. We design, manufacture and distribute quality products knowing they are used to save lives. Many of our products are required to be tested and approved by regulatory bodies worldwide. We believe in going beyond those specifications to ensure our products work when needed in real world conditions. With proper care and maintenance your ACR product will last for years. It is important that you thoroughly read this Product Support Manual to understand the proper care and use of your ACR product. ACR is proud to be certified to ISO 9001: 2000, the International Standard for Quality. This manual provides operation and maintenance instructions for the FPR-30.
Y1-03-0236F 3
-
SECTION 2 PREPARING TO INSTALL UNPACKING THE FPR-30 Before proceeding with the installation of the FPR-30, please verify that the content of the box includes the following:
Figure 1 items: 1. RLB-36/37/38 programming head cable* 2. FPR-30 software CD ROM* 3. FPR-30 hardware* 4. USB cable* 5. Programming head, RLB-36/37/38* 6. Face plate, PLB-200/ 201 7. Face plate, PLB-300/PLB-350B (one-button keypad) 8. PLB-350B/C (two-button keypad)* 9. PLB Optical interface cable* *These items are new relative to the components included with the FPR-20, a predecessor product. If any of the above is missing, please contact ACR Electronics Technical Service by email at [email protected] or by phone at +1 (954) 981- 3333. Please be ready to provide the serial number of your unit and location of purchase.
Equipment required but not included: // Computer with suitable operating system and software (see
upcoming section for details) // Printer compatible with Avery labels (as described below)
Figure 1
1
2
3 4
5 6
7
8 9
Y1-03-0236F 4
-
// Labels for reprogrammed beacons (Avery TEMPLATE 5167,
size 1.75 x 0.5, or 4.45cm x 1.27cm) // Label over-laminate (ACR Part Number 7069 over laminate) ANATOMY OF THE FPR-30 The FPR-30 is assembled in this manner (see Appendix B for PLB assembly variations):
Figure 2
EPIRB: Use RLB-36/37/38 programming head PLB: Use face plate according to model number
EPIRB: Use programming head cable PLB: Use optical interface cable
USB cable
EPIRB (not included): The FPR-30 is compatible with RLB-36 and higher models PLB (not included): The FPR-30 is compatible with PLB-200 and higher models
Computer (not included): Your computer needs to have FPR-30 software installed on it.
FPR-30 hardware unit
Y1-03-0236F 5
-
SYSTEM REQUIREMENTS
Operating systems
The FPR-30 software is compatible with the following operating systems:
// Windows XP with Service Pack 3 or later installed // Windows Vista // Windows 7
Required computer capabilities // A printer is required to produce beacon labels for the new identity to which the beacon was programmed // Microsoft Excel (part of Microsoft Office suite), any revision level, is required to automatically save and store data. This program must be on your computer to successfully install and run FPR-30 software. // If using Microsoft Windows XP, Service Pack 3 or later must be installed on your computer to successfully install FPR-30 software. // WinZip 6.0 or higher, to download and install FPR-30 software from ACR website. You will need to update your software periodically.
Other recommended FPR-30 computer capabilities
// Internet access, to decode beacons on the Cospas-Sarsat website SECTION 3 INSTALLING THE FPR-30 SOFTWARE INSTALLING THE FPR-30 SOFTWARE FROM THE CD ROM If you have the FPR-30 installation CD you do not need to download the software off the ACR website. The setup program will install all the needed files to your hard drive automatically. The software must be installed in the C:\Program Files\FPR30 directory to function properly. This directory is the default directory in the setup program. If you have a previous version installed, you must first uninstall it, before installation of the FPR-30. 1) Place the CD in the appropriate drive of your computer and close
the drive. 2) Plug the USB cable to the FPR-30 hardware and the other end to
the computer. The OS will load the USB drivers needed.
3) If the CD does not automatically run the installation process, click the START button on the bottom of your Windows operating system and select RUN.
Y1-03-0236F 6
-
4) Alternatively, use the file manager or Windows Explorer to find the
setup.exe file on the CD, double-click on setup.exe, and follow the installation instructions.
5) Follow the installation directions on the screen. 6) A panel will appear following installation containing the FPR-30
shortcut icon. Drag the icon to the desktop. DOWNLOADING AND INSTALLING FPR-30 SOFTWARE FROM THE ACR BRC WEBSITE The FPR-30 software may be downloaded from the web at http://www.acrartex.com. Please follow this link and select FPR 30 Software: http://www.acrartex.com/support/acr-support/ 1) If you have a previous version of the FPR-30 software installed,
uninstall it first.
2) Create a folder on your C drive to save this FPR 30 zip file. Do not unzip directly from the website.
3) Click on the fpr30.zip file.
4) A file download window will pop up. Select SAVE.
5) A SAVE AS window will pop up. Find the folder you created in step (2) and click SAVE.
6) When attempting to unzip this file, you will be prompted to enter a password under the Options menu and then extract the file to the hard drive.
7) Once the file has finished downloading, open the folder that you saved the file in and unzip it onto your hard drive. You will need to have WinZip 6.0 or higher installed on your computer in order to extract this file. If you do not have this program, you can download a free sample version at www.winzip.com.
8) The software is now ready to be installed. Typically, once WinZip has extracted the files, it will start to run the setup program for you. Select the OK button and follow the installation instructions. Your file will be saved to your C drive. Create a separate folder for it called FPR30.
// If the program does not start the installation, select the START button, click on RUN, type C:\FPR30\setup.exe. Select OK.
Y1-03-0236F 7
-
// Alternatively, use the file manager or Windows Explorer to find the setup.exe file on C:\, double click on setup.exe, and follow the installation instructions.
INSTALLING A USB DRIVER When the FPR-30 hardware is enabled (plugged in), for the first time, your Windows OS will detect a new USB device and ask for drivers. Refer to the FPR-30 USB directory on the CD ROM for USB driver installation instructions. USB driver installations under Windows Vista may result in Windows asking you if you wish to keep later versions of DLL files (included with Windows Vista) or if you prefer to use the versions provided on the FPR-30 installation CD. If this occurs, keep the later versions (included with Windows Vista). ADDING A PRINTER If you do not have a printer already connected, you will need to install one to your computer. For more information regarding adding a printer, please consult your Windows user manual or visit the Microsoft website at www.Microsoft.com, using the keywords Adding Printer. CONNECTING THE FPR-30 TO YOUR COMPUTER The FPR-30 device is connected to your computer by using the USB cable included in your kit. The USB connection provides power to the FPR-30 (see Figure 2). SECTION 4 PROGRAMMING A BEACON OVERVIEW The FPR-30 is designed to be a programming tool for current ACR PLBs and ACR EPIRBs, model number RLB-36 and higher. The FPR-30 supports the following ACR Electronics 406 MHz beacons:
TABLE-Beacons supported by FPR-30
Product name Model number AquaFix 406 GPS PLB PLB-200/ 201 TerraFix 406 GPS PLB PLB-200/ 201 AeroFix 406 GPS PLB PLB-200/ 201 ResQFix 406 GPS PLB PLB-300 MicroFix 406 GPS PLB PLB-300
AquaLink GPS PLB PLB-350B SARLink GPS PLB PLB-350B
AquaLink View GPS PLB PLB-350C SARLink View GPS PLB PLB-350C
GlobalFix iPRO, PRO, SAT3 EPIRB RLB-36/37/38
Y1-03-0236F 8
-
NOTE: The FPR-30 supports all beacon product numbers that correspond to the above models. NOTE: Go to the ACR BRC website (using the instructions in Section 3) for the most current version of the FPR-30 software. All upgrades to the FPR-30 software will be free to the owners of the FPR-30. All owners will be informed of new upgrades as they are available. PLEASE KEEP YOUR CONTACT INFORMATION CURRENT. Additional beacon models may be supported as they become available. When you select the FPR-30 icon, the program launches. The first screen describes the software and product by name and by revision number. The second screen presents five different tabs, each representing an FPR-30 function: Program, Read, Reset and Print. Use Program to change the country code of a beacon. Use Read to check the current programming of a beacon or to verify
that you have programmed a beacon correctly. Use Print to generate new labels for the beacon. The Reset tab that is inactive in the FPR-30: This feature is only
available in the FPR-300.
STEP ONE- OPEN THE FPR-30 PROGRAM
Double click the FPR-30 shortcut icon on the desktop. Note that the visual quality of the full screen displayed in the window is dependent on the resolution settings of the PC. The resolution can be adjusted through the display option of the Control Panel in your Windows operating system.
Y1-03-0236F 9
-
STEP TWO- PROGRAMMING
Preparing to program
A user wishing to re-program a beacon is guided through a series of selections designed to help input the specific information that will be used by the software to generate the Unique Identity Number (UIN). Programming the actual beacon is accomplished with a programming head and plug adapter.
NOTE: The FPR-30 requires the following information to generate a UIN (15-digit hex ID). This information must be valid and must be obtained from either the owner of the beacon or the SAR authorities of the country for which the beacon is being programmed. Make sure you have all of this information readily available before you begin the programming procedure. 1.) Beacon serial number, MMSI, aircraft code or radio call sign
(whichever is appropriate for the beacon type and the countrys requirements).
2.) Standard (default), National protocol or whichever is appropriate for the country of programming.
NOTE: Different ACR beacons only allow certain data (S/N, MMSI etc) to be programmed into them. The information, which may be input into the FPR-30 software, is made available (highlighted) after you have selected the protocol that is applicable. Some information is not permitted for a given beacon type, and these invalid choices are grayed-out, or inactive, to prevent data entry errors. Programming is accomplished by the computer generating a Unique Identification Number (UIN). This number is based on the information that the user of the FPR-30 provides via the different option windows. The data entered is sent to the FPR-30 hardware and from there to the appropriate programming head. The programming head handles all further communications with the beacons via infrared data transfer.
Y1-03-0236F 10
-
Initiating the programming process
1) Select Beacon in the upper left corner 2) Select the beacon model that you want to reprogram from the drop
down menu 3) Select the category and product number of the beacon that you want
to reprogram. 4) Select a country code by clicking on the Enter Country or Scroll
Down for List text box. Enter the country code or scroll down the list to the required country. Select that country. // NOTE: To view the menu of countries to choose from, click in the white box
5) Select Protocol.
// NOTE: Valid choices are active (in black lettering) and invalid choices are inactive (in grey lettering). If no choice is made, the system will use the default protocol, which is Standard Location Protocol. // NOTE: If applicable, refer to the upcoming section on programming a beacon back to the USA.
6) Enter the serial number or other preferred input (e.g., MMSI; see note
on page 9)
5. Select protocol
6. Enter serial number
1. Select Beacon
2,3. Drop down menu will appear here
4. Select Country
Y1-03-0236F 11
-
// NOTE: The serial number is found on the exterior of the beacon, on a white label. (If not, refer to STEP 4 section of this manual, Page 19.)
7) As soon as the beacon (product number) is selected, the Program
and Read tabs become available. The Print function is not available at this point.
NOTE: Maritime Mobile Ship Identity, or MMSI, is defined as the nine-digit ship identification number. The MMSI number incorporates the country code (the first three digits) followed by the ship's unique numeric identifier (the last six digits). CAUTION: When programming an MMSI into a beacon, it must be valid for the ship that will be carrying the beacon you are programming.
1.) Select Program tab (not the Program button at the bottom of the screen).
2.) Select PROGRAM button (not the Program tab at the top of the screen).The software will now request that a memory read be performed, to ascertain that all the needed parameters are correct.
3.) The system advises that it is ready to program a beacon to a new location.
1. Select Program tab
2. Select READ button 3. Message:
Program to POS
Y1-03-0236F 12
-
Programming the beacon
4.) Follow prompt to place the faceplate or programming head on the
beacon and click on the Read button. Perform a Self-test. This enables the FPR-300 software to read the beacon memory.
NOTE: The beacon is NOT being programmed at this point in the process. NOTE: Each beacon has 2 (two) memory positions: An ACR memory position and a POS (Point of Sale) memory position. When an ACR beacon is manufactured, it is programmed with a sequential manufacturers serial number and the USA country code. This data is inserted in the ACR position. The ACR ID stays within the beacon as long as it remains a functional device. When a beacon is reprogrammed, the new ID is inserted in the POS (Point Of Sale) position. Any additional reprogramming will always insert the new ID in the POS position.
4. Prompt: Place programming head
Y1-03-0236F 13
-
5.) Select the Program button. This allows the programming sequence. 6.) A new message above the Program button advises that the UIN number has now been generated and is ready to be programmed into the unit, i.e., Program to POS location. UIN: XXXXXXXXXXXXXXXX. 3.) Select Program button. 4.) Follow the prompt to place programming head on the beacon. Wait for the LED on the head to light and then perform a Self-test.
5.) A message Beacon programmed will be shown above the Program button.
5. Message: Beacon Programmed
Y1-03-0236F 14
-
Printing labels
1.) Select the Print tab. 2.) You may enter the user name, vessel name or any other name that
the beacon owner wants in the space provided. 3.) Print by selecting the column of labels you want to print on, e.g.,
Column 1, 2, 3 or 4. The FPR-300 program uses Avery TEMPLATE 5167 labels or comparable substitute. The format for the sheet of labels is four columns.
Column 1 2 3 4
2. Enter name
3. Select column of labels you want to print
Y1-03-0236F 15
-
After printing the labels, the unit can now be programmed. 7.) Compare the ID with the label that was printed to make absolutely sure that they are the same. 8.) At this stage, you must attach the newly printed ID label to the beacon. Remove the old label, clean the area properly and put the new label on. Use the TOP label of the column that was printed. NOTE: The beacon serial number label must be covered with over-laminate in order to avoid damage to the label that would cause it to become unreadable. This can be ordered from ACR under P/N 9569
SPECIAL PROGRAMMING ISSUES
If reprogramming a beacon back to the USA:
The FPR Software will first determine whether the beacons original ACR serial number and the serial number that has been provided (that you want to program the beacon with) are identical. If they are not identical the system will disallow reprogramming and provide the following message:
SERIAL NUMBER NOT ALLOWED: If you are attempting to reprogram a beacon back to the USA, there may be an issue with the serial number that was input into the system. (You are only allowed to use serial number _____.) Please contact ACR Electronics Technical Service for further assistance.
Select OK and the system will return to the initial startup screen. Enter the serial number provided and repeat the programming process.
Y1-03-0236F 16
-
Reprogramming a beacon to any country
When reprogramming a beacon to any country, the system will confirm the reprogramming intention by asking you to confirm what you want to do:
You are requesting to reprogram from ________ (current country programmed in beacon, e.g., USA) to _________ (requested country to be programmed in beacon, e.g., UK). Is this correct?
If you answer No, the FPR-30 will return to the initial startup screen. If you answer Yes the system proceeds to the next screen in the sequence.
Y1-03-0236F 17
-
Programming a beacon to a serial number that is not the original
If you want to reprogram a beacon to anything but the original ACR serial number, you will receive the message:
WARNING: Please be aware of the responsibility in programming beacons.Contact ACR Electronics Inc. with any questions or concerns.
If you select Cancel, the FPR-30 will return to the initial startup screen. If you answer OK the system will proceed to the next screen in the sequence.
Time out error message
If you wait longer than fifteen (15) seconds when prompted to press the Program button, you will see a text box appear with the following error message: No response from beacon: Please try again. Press the Program button to continue.
Y1-03-0236F 18
-
STEP FOUR- PROGRAMMING VERIFICATION
Identifying a current serial number
There are two ways to recover the existing serial number of the unit. The first is the identification label. After the S/N., the actual serial number appears. This number is the present serial number in the unit. If the label is defaced in any way, there is a second way to recover the serial number.
Memory read/ Verifying correct serial number
If you want to read the memory of a unit after it has been programmed, do the following:
1.) Select the Read tab
2.) Follow the prompt and initiate the self-test feature on the beacon (EPIRB = switch, PLB = button). This enables the FPR-30 to read the beacon memory.
1. Select Read
2. Prompt: Select TEST button/switch on beacon
Y1-03-0236F 19
-
3.) The new identity will now be displayed in the POS (Point of Sale)
Content position. If the beacon was never reprogrammed after it left ACR, the ACR content will have the only HEX ID, the POS content will be void (empty). The correct serial number is displayed on the top right of window.
4.) To verify whether the beacon was programmed to the instructions of the owner, the following can be done, the document can be printed and given to the owner:
Go to the Cospas-Sarsat website; http://www.cospas-sarsat.int/en/beacon-decode-program
Enter the beacon HEX ID (15 digit code) under 1 Be aware that the HEX message consists of numbers 0-9 and
letters A-F only. Select PROCESS when finished
5.) The result will be as follows:
3. POS Content
Correct Serial Number
Y1-03-0236F 20
-
406 MHz Decode Program (Version 3.2) 1. Enter Beacon ID 15 Hex or Message (22 Hex or 30 Hex)
2. Pick Hex Format
15 Hexadecimal
22 Hexadecimal
30 Hexadecimal
3. Click "Process" when ready Process ITU List of MID Country Code Numbers
ITEM BITS VALUE
Message format: Not provided in 15 hex id 25
Protocol: Location Protocol 26 0
Country code: 366 - United States of America 27-36 0101101110
Type of location protocol: Standard Location - PLB (Serial)
37-40 0111
Cospas-Sarsat #: 219 41-50 0011011011
Serial Number: 4446 51-64 01000101011110
Latitude Sign: default 65 0
Latitude Degrees: default 66-72 1111111
Latitude Minutes: default 73-74 11
Longitude Sign: default 75 0
Longitude Degrees: default 76-83 11111111
Longitude Minutes: default 84-85 11
Composite Latitude: default N/A Composite Longitude: default
15 Hex ID: N/A 2DCE6DA2BCFFBFF
HEX ID programmed into the beacon.
Y1-03-0236F 21
-
APPENDIX A- USING AUTO-SAVED DATA The data generated during beacon reprogramming is automatically stored to a Microsoft Excel file. You do not need to set up this feature. The Excel file will look like this:
To use this feature
The directory where the Microsoft Excel file of saved data can be found is C:\Program Files\FPR30\ You may view, sort, edit and print the data by using standard Microsoft Excel commands and functions. You may add information, such as customer name and address, ship name, etc., in the unused columns. NOTE: If you do not have a file viewer you will not be able to view the files saved. File Viewer is available from Microsoft Downloads
CAUTION: DO NOT OPEN the Microsoft Excel file of saved data while the FPR-300 program is open. Doing so will cause a conflict: The Excel file and the FPR-300 software cannot be open at the same time.
Y1-03-0236F 22
-
APPENDIX B TIPS FOR PROGRAMMING BEACONS The following is background information that may be helpful for individuals that program ACR Electronics beacons. Tips regarding PLB-300/PLB-350 programming NOTE: When using the button to initiate different beacon functions, please be aware of the different time requirements for the button. If you hold the button just a fraction too long when trying to program, the unit may enter a mode other than the one intended.
Figure 3 - FPR-30 and PLB 300/PLB-350 Connection
The PLB-300/PLB-350 beacons use the SELF TEST button to execute three functions: 1.) Programming // Flick (press with a firm and rapid movement) the Self Test button to see the red LED flash briefly. 2.) Self Test Sequence // Press the Self Test button for one second* and release to initiate the self test (*count by saying one thousand and one). 3.) GPS Acquisition Test // Press the Self Test button for five seconds or longer to initiate the test. Programming ACR PLB-300s/PLB-350s PLB-300s and PLB-350s shipped from ACR Electronics are typically programmed with the USA country code. If you want to reprogram the unit to another country code and protocol, do the following:
PLB-300 or PLB-350 (one-button)
PLB-350 (two-button)
Y1-03-0236F 23
-
1) Put the appropriate plastic faceplate and optical interface heads on
the PLB front face. 2) Set up all of the required data on the FPR-30. 3) If you are sure that all the entered data is correct, select
Program button. 4) The Programmer now asks for a Read function to be executed,
to revert to the correct Cospas-Sarsat TAC number. Flick the Self Test button.
5) Select Program button again to initiate the final step. 6) Flick the test button again to program. 7) If successful, the Beacon programmed message will be shown
above the dimmed Program button.
Tips regarding PLB-200/201 programming The PLB-200/201 is programmed by means of the GPS I/O or GPS I
button .
Figure 4-FPR-30 and PLB-200 Connection
7.) Select Program button again to initiate the final step. 8.) Press the I/O or I button again to program. 9.) If successful, the Beacon programmed message will be shown
above the dimmed Program button.
1.) Programming is done by means of the GPS I.O. or I button.
2.) When the program prompts the programmer,
this button has to be pressed for 1 (one) second and then RELEASED.
3.) Put the plastic faceplate and optical interface
heads on the PLB front face. 4.) Set up all of the required data on the FPR-
30. 5.) Ensure that all the entered data is correct,
then select Program button. 6.) The FPR-30 program now asks for a Read
function to be executed, to revert to the correct COSPAS - SARSAT TAC number. Press the I/O or I button.
Y1-03-0236F 24
-
Tips regarding RLB-36/37/38 programming To reprogram the unit to another country code and protocol: 1.) Place the programming head over the antenna base on the top of the
EPIRB. 2.) Set up all your data (Serial number, protocol, country code) in the
FPR 30. 3.) If you are sure that all data is correct and can be verified, click on the
Program button. 4.) The FPR-30 now asks for a READ function to be executed in order
to revert to the correct COSPAS - SARSAT TAC number; the light on the programming head will be lit and you must now lift the activation switch to a vertical position for 2 seconds, then let it drop down.
5.) The final UIN is now generated by the software and a prompt to
program is again displayed. 6.) Click on the Program button to initiate the final programming step. 7.) Lift the activation switch again to program. 8.) If successful, the Beacon programmed message will be shown
above the dimmed Program button.
The Battery Witness reset procedure is the same as the programming procedure. Select the READ tab, click the Reset button and lift the activation switch for 2 seconds while the programming head light is lit.
APPENDIX C- MAKING A NEW LABEL FOR A BEACON This is done when the old label is gone or has deteriorated to such an extent that it needs to be replaced, without having to reprogram the beacon. Do a READ of the beacon memory and select the PRINT button on the bottom right. Compare the ID in the ACR or POS position with the label to make sure that they match.
Y1-03-0236F 25
-
APPENDIX D RESETTING DIGITAL DISPLAY LANGUAGE (RLB-36)
1.) Select the Reset tab 2.) Select Set Language
3.) From the menu of languages on the left side of the screen, click on
the language of choice. The beacon is manufactured with English installed.
4.) Place programming head on beacon and perform a self-test
1. Select Reset tab
4. Place programming head
2. Select Set Language
Y1-03-0236F 26
-
5.) The GlobalFix iPRO digital display language has been
successfully changed.
5. The language has been reset
Y1-03-0236F 27
-
APPENDIX E TECHNICAL SPECIFICATIONS
ACR PRODUCT NUMBER
FPR-30 Product number 2902
GENERAL
FPR Size 2.25 X 3.375 X 1.0 inches (5.72 X 8.57 X 2.54 cm)
Casing material Aluminum
Casing color Black
Waterproof No
Buoyant No
POWER
USB port 100mAmp capability
SOFTWARE UPDATES
Obtain via web Via ACRs website; password necessary
Request a CD ROM Call ACR Electronics customer support
COMPUTER REQUIREMENTS
Operating system compatibility
Windows Vista, Windows XP (with Service Pack 3 or later)
Software requirements Microsoft Excel (any version), WinZip revision 6.0 or higher
Hardware requirements Printer
Computer system requirements
Refer to minimum and recommended requirements for your OS as published on the Microsoft website
GENERAL
ACR 406MHz beacons supported
All current ACR PLBs, ACR EPIRBs with model numbers RLB-36 and higher
KIT CONTENTS
Kit See Figure 1 for complete list
Y1-03-0236F 28
-
MISCELLANEOUS
Accessories Replacement programming heads for beacons available: See ACR Electronics website, price list or contact ACR.
Labels The FPR-30 kit does not include blank labels.FPR-30 compatible labels are Avery TEMPLATE 5167, which are 1.75 X 0.5 (4.45 X 1.27 cm) in size. You may purchase labels from the vendor of your choice in person or via the internet. Search Avery labels. There are a number of vendors who ship worldwide.
Units per carton One (1)
APPROVALS
NOTE: For complete information regarding standards and certifications, please visit ACRs website at www.acrartex.com.
APPENDIX F WARRANTY, NOTICES
LIMITED WARRANTY This product is warranted against factory defects in material and workmanship for a period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost to you for labor, materials and return transportation from ACR. For further assistance, please contact our Technical Service Department at ACR Electronics, Inc.,5757 Ravenswood Road, Fort Lauderdale, FL 33312-6645. Email: [email protected], Fax: +1 (954) 983-5087, Telephone: +1 (954) 981-3333. This warranty does not apply if the product has been damaged by accident or misuse, or as a result of service or modification performed by an unauthorized factory. Except as otherwise expressly stated in the previous paragraph, THE COMPANY MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ANY OTHER MATTER WITH RESPECT TO THIS PRODUCT. The Company shall not be liable for consequential or special damages. To place the warranty in effect, register online at www.acrartex.com or return the attached card within 10 days. *Five years for the following products: EPIRB, PLB, S-VDR, SSAS.
Y1-03-0236F 29
-
NOTICES ACR Electronics diligently works to provide a high quality Product Support Manual, however, despite best efforts, information is subject to change without notice, and omissions and inaccuracies are possible. ACR cannot accept liability for manual contents. To ensure that you have the most recent version of the Product Support Manual, please visit the ACR website at www.acrartex.com. 2008 by ACR Electronics, Inc. All rights reserved. Reproduction in whole or in part is permitted only with permission of ACR Electronics, Inc. Ongoing product improvements may change product specifications without notice. Trademarks or registered trademarks are the property of their respective owners.
Y1-03-0236F 30
SECTION 1 INTRODUCTIONSECTION 2 PREPARING TO INSTALLUNPACKING THE FPR-30Equipment required but not included:
ANATOMY OF THE FPR-30SYSTEM REQUIREMENTSOperating systemsRequired computer capabilitiesOther recommended FPR-30 computer capabilities
SECTION 3 INSTALLING THE FPR-30 SOFTWAREINSTALLING THE FPR-30 SOFTWARE FROM THE CD ROMDOWNLOADING AND INSTALLING FPR-30 SOFTWARE FROM THE ACR BRC WEBSITEINSTALLING A USB DRIVERADDING A PRINTERCONNECTING THE FPR-30 TO YOUR COMPUTER
SECTION 4 PROGRAMMING A BEACONOVERVIEWSTEP ONE- OPEN THE FPR-30 PROGRAMSTEP TWO- PROGRAMMINGPreparing to programInitiating the programming processProgramming the beacon
SPECIAL PROGRAMMING ISSUESIf reprogramming a beacon back to the USA:Reprogramming a beacon to any countryTime out error message