cutting led estrip energizing system note joining two ... · m) make sure to disconnect the power...

2
A) Do not operate with the flexible light tightly coiled. B) During installation, make sure flexible light isn’t receiving electricity in any manner. C) Make sure the voltage marked on your light strip matches the power supply. D) Do not overlap this product as the overlapping may cause the flexible light to overheat and melt or ignite. E) Do not cover this product as the covering may cause the flexible light to overheat and melt or ignite. F) Do not puncture the flexible lighting. G) Do not route flexible lighting through walls, doors, windows or any like part of the building structure. See wiring diagrams below for remote power source installations. H) Do not use if there is any damage to the light or cord insulation. Inspect periodically. I) Do not submerge flexible light in liquids, or use the product in the vicinity of standing water or other liquids. Keep all parts of LED eStrip installation at least 10 feet from any swimming or decorative pool. J) Secure this flexible light using only the hangers or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation. K) Do not subject flexible lighting to continuous flexing. L) Do not exceed the length in feet permitted by the marking. M) Make sure to disconnect the power before adding segments. N) Only use extension segments provided with the entire set of product. O) To preclude the entry of water, make sure that all connections between section segments provided with the entire set of product. P) Do not bend the LED eStrip in the horizontal plane at all. Use “T”, “+”, “L”, or step cords instead. Maintain a minimum 2” radius in the vertical plane. Q) Do not subject flexible light to over 35 lbs of tensile force. R) When connecting the flexible light with connectors, step cord, and the power supply (LED driver), make sure the polarity markings are correctly matched. WARNING & CAUTIONS INSTALLATION DISCONNECT all power before cutting, adding connectors, adding additional LED eStrip, modifying or moving the product in any manner! CUTTING LED eSTRIP Cut LED eStrip to desired length (nearest cutting line located every 6”) with sharp knife or cable cutters (Figure A). Do not exceed a total of 90 feet of LED eStrip in any single run. Do not exceed total wattage rating of power supply being used. INSTALLING CONNECTORS 1) Line up positive and negative polarity markings on male connector with markings on LED eStrip. Place male connector over cut end of LED eStrip and push together firmly (See Figure B). INSTALLING END CAP Place end cap over dead end of LED eStrip. Secure with a small amount of silicon glue (Figure D). INSTALLING LOW VOLTAGE POWER CORD Making sure correct polarity from cord to LED Driver, connect wires from connector to low voltage power supply. Use appropriate strain relief to secure power cord to LED Driver. ENERGIZING SYSTEM Connect LED Driver to main power (120 volt). NOTE – 120 volt connections to low voltage power supply should be carried out by qualified electrician. JOINING TWO PIECES OF LED ESTRIP CAUTION: When joining two pieces of LED eStrip together, MAKE SURE COMBINED LENGTHS OF TWO PIECES DO NOT EXCEED 90 FEET OF PRODUCT. Do not exceed rated wattage of power supply. 1) Disconnect 120VAC from power supply. 2) Remove end cap from LED eStrip, if applicable (Figure E). Clean of glue. 3) Line up positive and negative polarity markings on female part of inline connector with markings on LED eStrip. Place connector over cut end of LED eStrip and push together firmly (Figure F). 4) Screw threaded contacts of connector into LED eStrip until tight and plastic part of connector is seated firmly against LED eStrip (Figure G). S) When using outdoor use portable lighting products, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury, including the following: 1) Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuits or outlet to be used for the outdoor use of flexible lighting product. Receptacles are available having built-in GFCI protection for this measure of safety. 2) Use only listed outdoor extension cord from 120VAC source to LED Driver, such as type SW, SOW, STW, STOW, SJW, SJOW, SJTW, or SJTOW. This designation is marked on the wire of the extension cord. T) Do not mount to any surface that has temperatures exceeding -40F to +104F. 2) Screw threaded contacts of connector into LED eStrip until tight and plastic part of connector is seated firmly against product (Figure B). 3) Connect to power supply connector making sure polarity markings are matched (Figure C). 5) Repeat steps 3 and 4 for male side of inline connector. 6) Line up positive and negative polarity marks on inline connectors and push together until flaps are locked together (Figure H). 7) Note: IMPORTANT SAFETY PRECAUTION! Female side of inline connector should always be attached to the length of LED eStrip that will be attached to power supply. 8) Place end cap over dead end of LED eStrip and secure with a small amount of silicon glue. USING SPECIAL CONNECTORS When using one of NSL’s special connectors (LES-BFXN, LES-BFTR, LES-BFTD or LES-BFLN) please follow steps 1-5 above. After completing steps 1-5, connect special connector to inline connector by matching appropriate ends and pushing firmly together. To reduce the risk of fire, electrical shock, or injury to persons: LED DRIVER SELECTION Dimmable Min. Max. Low Power Non-Dimming Feet Feet LES-24-65W (Indoor only) Non-Dimming 1 65 LEDDR-24-120W Non-Dimming 1 120 TRE24L40DC Both 18 40 TRE24L96DC Both 48 90 Dimmable Min. Max. High Power Non-Dimming Feet Feet LES-24-65W (Indoor only) Non-Dimming 1 20 LEDDR-24-120W Non-Dimming 1 42 TRE24L40DC Both 8 18 TRE24L96DC Both 22 42 If you do not wish to dim the LED eStrip use any of the LED Drivers listed above and be careful to abide by the minimum and maximum load values listed above. If you wish to dim the LED eStrip, use only the TRE24L40DC, or TRE24L96DC and a low voltage dimmer listed below. All dimmable LED Drivers have no minimum load when used with an appropriate dimmer, however, all dimmable LED Drivers are more efficient if specified as per the minimum and maximum load values listed above. 1. Our dimmable power supplies are dimmable with any standard MLV/Incandescent TRIAC (Leading edge) dimmer switches. Dimmer switches are to be installed on the input (120VAC) of the driver. 2. Carefully following the dimmer instructions, dimmable LED power supply instructions, and the NEC, wire dimmer between 120VAC power input and 24 Volt Direct Current dimmable LED power supply. WARNING

Upload: others

Post on 28-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CUTTING LED eSTRIP ENERGIZING SYSTEM NOTE JOINING TWO ... · M) Make sure to disconnect the power before adding segments. N) Only use extension segments provided with the entire set

A) Do not operate with the flexible light tightly coiled.B) During installation, make sure flexible light isn’t

receiving electricity in any manner.C) Make sure the voltage marked on your light strip

matches the power supply.D) Do not overlap this product as the overlapping may

cause the flexible light to overheat and melt or ignite.E) Do not cover this product as the covering may cause the

flexible light to overheat and melt or ignite.F) Do not puncture the flexible lighting.G) Do not route flexible lighting through walls, doors,

windows or any like part of the building structure. See wiring diagrams below for remote power source installations.

H) Do not use if there is any damage to the light or cord insulation. Inspect periodically.

I) Do not submerge flexible light in liquids, or use the product in the vicinity of standing water or other liquids. Keep all parts of LED eStrip installation at least 10 feet from any swimming or decorative pool.

J) Secure this flexible light using only the hangers or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation.

K) Do not subject flexible lighting to continuous flexing.L) Do not exceed the length in feet permitted by the

marking.M) Make sure to disconnect the power before adding

segments.N) Only use extension segments provided with the entire

set of product.O) To preclude the entry of water, make sure that all

connections between section segments provided with the entire set of product.

P) Do not bend the LED eStrip in the horizontal plane at all. Use “T”, “+”, “L”, or step cords instead. Maintain a minimum 2” radius in the vertical plane.

Q) Do not subject flexible light to over 35 lbs of tensile force.

R) When connecting the flexible light with connectors, step cord, and the power supply (LED driver), make sure the polarity markings are correctly matched.

WARNING & CAUTIONS

INSTALLATION

DISCONNECT all power before cutting, adding connectors, adding additional LED eStrip, modifying or moving the product in any manner!

CUTTING LED eSTRIPCut LED eStrip to desired length (nearest cutting line located every 6”) with sharp knife or cable cutters (Figure A). Do not exceed a total of 90 feet of LED eStrip in any single run. Do not exceed total wattage rating of power supply being used.

INSTALLING CONNECTORS

1)

Line up positive and negative polarity markings on male connector with markings on LED eStrip. Place male connector over cut end of LED eStrip and push together firmly (See Figure B).

INSTALLING END CAP

Place end cap over dead end of LED eStrip. Secure with a small amount of silicon glue (Figure D).

INSTALLING LOW VOLTAGE POWER CORD

Making sure correct polarity from cord to LED Driver, connect wires from connector to low voltage power supply. Use appropriate strain relief to secure power cord to LED Driver.

ENERGIZING SYSTEM

Connect LED Driver to main power (120 volt). NOTE – 120 volt connections to low voltage power supply should be carried out by qualified electrician.

JOINING TWO PIECES OF LED ESTRIP CAUTION: When joining two pieces of LED eStrip together, MAKE SURE COMBINED LENGTHS OF TWO PIECES DO NOT EXCEED 90 FEET OF PRODUCT. Do not exceed rated wattage of power supply.

1) Disconnect 120VAC from power supply.

2) Remove end cap from LED eStrip, if applicable (Figure E). Clean of glue.

3) Line up positive and negative polarity markings on female part of inline connector with markings on LED eStrip. Place connector over cut end of LED eStrip and push together firmly (Figure F).

4) Screw threaded contacts of connector into LED eStrip until tight and plastic part of connector is seated firmly against LED eStrip (Figure G).

S) When using outdoor use portable lighting products, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and personal injury, including the following:

1) Ground Fault Circuit Interrupter (GFCI) protection should be provided on the circuits or outlet to be used for the outdoor use of flexible lighting product. Receptacles are available having built-in GFCI protection for this measure of safety.

2) Use only listed outdoor extension cord from 120VAC source to LED Driver, such as type SW, SOW, STW, STOW, SJW, SJOW, SJTW, or SJTOW. This designation is marked on the wire of the extension cord.

T) Do not mount to any surface that has temperatures exceeding -40F to +104F.

BE SURE TO MATCH POLARITY MARKINGS. 4. MOUNTING ACCESSORIES FOR MICRO LED LIGHT CABLE

USE OF MOUNTING ACCESSORIES

A) Cut Light Cable to desired length (nearest cutting line) with sharp knife or cable cutters. (Figure A) Refer to maximum lengths in specifications shown above. Do not exceed maximum recommended length of light cable. Do not exceed total wattage rating of power supply being used

B) Line up positive and negative polarity markings on male connector with markings on light cable. Place male connector over cut end of light cable and push together firmly. (See figure B)

C) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable. (Figure B)

D) Connect to power supply connector making sure polarity markings are matched. (Figure C)

E) Place end cap over dead end of light cable. (Figure D)

F) Connect wires from connector to low voltage power supply.

G) Connect low voltage power supply to main power (120 volt). Note – 120 volt connections to low voltage power supply should be carried out by qualified electrician.

2. JOINING TWO PIECES OF MICRO LED LIGHT CABLE TOGETHER. CAUTION: When joining two pieces of Micro LED Light Cable

together, MAKE SURE COMBINED LENGTHS OF TWO PIECES DO NOT EXCEED 100 WATTS IN POWER CONSUMPTION. Do not exceed rated wattage of power supply

A) Disconnect from power supply.

B) Remove end cap from Light Cable (if applicable) (Figure E)

C) Line up positive and negative polarity markings on female part of inline connector with markings on light cable. Place connector over cut end of light cable and push together firmly. (Figure F)

D) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable.(Figure G)

E) Repeat steps C and D for male side of inline connector.

F) Line up positive and negative polarity marks on in line connectors and push together until flaps are locked together.(Figure H)

G) Note: IMPORTANT SAFETY PRECAUTION! Female side of inline connector should always be attached to the length of light cable that will be attached to power supply.

H) Place end cap over dead end of LED Light Cable. (Figure D)

3. USING SPECIAL CONNECTORS.

When using one of Magic Lite’s special connectors (MLS-EFSN, MLS-BFXN, MLS-BFTR, MLS-BFTD or MLS-BFLN) please follow steps A – E in step 2 above.

After completing steps A – E, connect special connector to inline connector by matching appropriate ends and pushing firmly together.

WARNING: RISK OF FIRE AND SHOCK

Warning: Risk of Fire and Shock 1. Do not cover this product as the covering may cause the flexible

light to overheat and melt or ignite.2. Do not operate with the flexible light tightly coiled. To prevent

overheating do not allow contact between flexible light cables and parts of light cables. Maintain at least 12 mm spacings between flexible light cables or parts of light cables.

3. Do not route the cord or flexible light cable through walls, doors, windows or any like part of the building structure.

4. Do not use if there is any damage to the light or cord insulation. Inspect periodically.

5. Do not submerge flexible light in liquids.6. Secure this flexible light cable using only the hangers, tracks

or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation.

7. DO NOT EXCEED THE MAXIMUM NUMBER OF EXTENSIONS OR FLEXIBLE LIGHT LENGTHS PERMITTED BY THE MARKING.

8. Do not install on gates or doors, where subject to flexing9. Do not install in cabinets, tanks or enclosures of any kind For Outdoor Installations:10. Caution: Ground Fault Circuit Interrupter (GFCI) protection

should be provided on the circuit or outlet.11. Caution: Use only outdoor extension cords, such as type SOW,

STW, SJOW or SJTW.12. Caution: Do not install closer than 3 meters from a swimming

pool surface13. All 120 Volt electrical connections to power supplies (drivers)

should be carried out by a qualified electrician. Power supplies used for outdoor applications must be enclosed in approved outdoor enclosure unless listed for wet locations.

14. Magic Lite offers a variety of power supplies for powering Micro LED Light Cable to suit your particular project. Power supplies vary in wattage rating and therefore will power various lengths of Micro LED Light Cable. Consult the list of power supplies in these instructions which indicate TOTAL FOOTAGE OF PRODUCT that each power supply will power. NEVER EXCEED THE MAXIMUM ALLOWABLE SINGLE RUN OF PRODUCT. Note that dimming power supplies have both maximum and minimum loads. Be sure to adhere to these restrictions when using dimmable power supplies.

INSTALLATIONDISCONNECT POWER BEFORE INSTALLING MICRO LED1. CONNECTING MICRO LED LIGHT CABLE TO POWER. Magic Lite Ltd MICRO LED LIGHT CABLE runs on 24 volt power

supply. Use only power supplies from Magic Lite Ltd. approved for use with Micro LED.

Use only extension segments and power cords provided by Magic Lite Ltd. for powering or extending Micro LED.

Make sure all end caps and connections are firmly seated to preclude the entry of water.

BE SURE TO MATCH POLARITY MARKINGS. 4. MOUNTING ACCESSORIES FOR MICRO LED LIGHT CABLE

USE OF MOUNTING ACCESSORIES

A) Cut Light Cable to desired length (nearest cutting line) with sharp knife or cable cutters. (Figure A) Refer to maximum lengths in specifications shown above. Do not exceed maximum recommended length of light cable. Do not exceed total wattage rating of power supply being used

B) Line up positive and negative polarity markings on male connector with markings on light cable. Place male connector over cut end of light cable and push together firmly. (See figure B)

C) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable. (Figure B)

D) Connect to power supply connector making sure polarity markings are matched. (Figure C)

E) Place end cap over dead end of light cable. (Figure D)

F) Connect wires from connector to low voltage power supply.

G) Connect low voltage power supply to main power (120 volt). Note – 120 volt connections to low voltage power supply should be carried out by qualified electrician.

2. JOINING TWO PIECES OF MICRO LED LIGHT CABLE TOGETHER. CAUTION: When joining two pieces of Micro LED Light Cable

together, MAKE SURE COMBINED LENGTHS OF TWO PIECES DO NOT EXCEED 100 WATTS IN POWER CONSUMPTION. Do not exceed rated wattage of power supply

A) Disconnect from power supply.

B) Remove end cap from Light Cable (if applicable) (Figure E)

C) Line up positive and negative polarity markings on female part of inline connector with markings on light cable. Place connector over cut end of light cable and push together firmly. (Figure F)

D) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable.(Figure G)

E) Repeat steps C and D for male side of inline connector.

F) Line up positive and negative polarity marks on in line connectors and push together until flaps are locked together.(Figure H)

G) Note: IMPORTANT SAFETY PRECAUTION! Female side of inline connector should always be attached to the length of light cable that will be attached to power supply.

H) Place end cap over dead end of LED Light Cable. (Figure D)

3. USING SPECIAL CONNECTORS.

When using one of Magic Lite’s special connectors (MLS-EFSN, MLS-BFXN, MLS-BFTR, MLS-BFTD or MLS-BFLN) please follow steps A – E in step 2 above.

After completing steps A – E, connect special connector to inline connector by matching appropriate ends and pushing firmly together.

WARNING: RISK OF FIRE AND SHOCK

Warning: Risk of Fire and Shock 1. Do not cover this product as the covering may cause the flexible

light to overheat and melt or ignite.2. Do not operate with the flexible light tightly coiled. To prevent

overheating do not allow contact between flexible light cables and parts of light cables. Maintain at least 12 mm spacings between flexible light cables or parts of light cables.

3. Do not route the cord or flexible light cable through walls, doors, windows or any like part of the building structure.

4. Do not use if there is any damage to the light or cord insulation. Inspect periodically.

5. Do not submerge flexible light in liquids.6. Secure this flexible light cable using only the hangers, tracks

or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation.

7. DO NOT EXCEED THE MAXIMUM NUMBER OF EXTENSIONS OR FLEXIBLE LIGHT LENGTHS PERMITTED BY THE MARKING.

8. Do not install on gates or doors, where subject to flexing9. Do not install in cabinets, tanks or enclosures of any kind For Outdoor Installations:10. Caution: Ground Fault Circuit Interrupter (GFCI) protection

should be provided on the circuit or outlet.11. Caution: Use only outdoor extension cords, such as type SOW,

STW, SJOW or SJTW.12. Caution: Do not install closer than 3 meters from a swimming

pool surface13. All 120 Volt electrical connections to power supplies (drivers)

should be carried out by a qualified electrician. Power supplies used for outdoor applications must be enclosed in approved outdoor enclosure unless listed for wet locations.

14. Magic Lite offers a variety of power supplies for powering Micro LED Light Cable to suit your particular project. Power supplies vary in wattage rating and therefore will power various lengths of Micro LED Light Cable. Consult the list of power supplies in these instructions which indicate TOTAL FOOTAGE OF PRODUCT that each power supply will power. NEVER EXCEED THE MAXIMUM ALLOWABLE SINGLE RUN OF PRODUCT. Note that dimming power supplies have both maximum and minimum loads. Be sure to adhere to these restrictions when using dimmable power supplies.

INSTALLATIONDISCONNECT POWER BEFORE INSTALLING MICRO LED1. CONNECTING MICRO LED LIGHT CABLE TO POWER. Magic Lite Ltd MICRO LED LIGHT CABLE runs on 24 volt power

supply. Use only power supplies from Magic Lite Ltd. approved for use with Micro LED.

Use only extension segments and power cords provided by Magic Lite Ltd. for powering or extending Micro LED.

Make sure all end caps and connections are firmly seated to preclude the entry of water.

BE SURE TO MATCH POLARITY MARKINGS. 4. MOUNTING ACCESSORIES FOR MICRO LED LIGHT CABLE

USE OF MOUNTING ACCESSORIES

A) Cut Light Cable to desired length (nearest cutting line) with sharp knife or cable cutters. (Figure A) Refer to maximum lengths in specifications shown above. Do not exceed maximum recommended length of light cable. Do not exceed total wattage rating of power supply being used

B) Line up positive and negative polarity markings on male connector with markings on light cable. Place male connector over cut end of light cable and push together firmly. (See figure B)

C) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable. (Figure B)

D) Connect to power supply connector making sure polarity markings are matched. (Figure C)

E) Place end cap over dead end of light cable. (Figure D)

F) Connect wires from connector to low voltage power supply.

G) Connect low voltage power supply to main power (120 volt). Note – 120 volt connections to low voltage power supply should be carried out by qualified electrician.

2. JOINING TWO PIECES OF MICRO LED LIGHT CABLE TOGETHER. CAUTION: When joining two pieces of Micro LED Light Cable

together, MAKE SURE COMBINED LENGTHS OF TWO PIECES DO NOT EXCEED 100 WATTS IN POWER CONSUMPTION. Do not exceed rated wattage of power supply

A) Disconnect from power supply.

B) Remove end cap from Light Cable (if applicable) (Figure E)

C) Line up positive and negative polarity markings on female part of inline connector with markings on light cable. Place connector over cut end of light cable and push together firmly. (Figure F)

D) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable.(Figure G)

E) Repeat steps C and D for male side of inline connector.

F) Line up positive and negative polarity marks on in line connectors and push together until flaps are locked together.(Figure H)

G) Note: IMPORTANT SAFETY PRECAUTION! Female side of inline connector should always be attached to the length of light cable that will be attached to power supply.

H) Place end cap over dead end of LED Light Cable. (Figure D)

3. USING SPECIAL CONNECTORS.

When using one of Magic Lite’s special connectors (MLS-EFSN, MLS-BFXN, MLS-BFTR, MLS-BFTD or MLS-BFLN) please follow steps A – E in step 2 above.

After completing steps A – E, connect special connector to inline connector by matching appropriate ends and pushing firmly together.

WARNING: RISK OF FIRE AND SHOCK

Warning: Risk of Fire and Shock 1. Do not cover this product as the covering may cause the flexible

light to overheat and melt or ignite.2. Do not operate with the flexible light tightly coiled. To prevent

overheating do not allow contact between flexible light cables and parts of light cables. Maintain at least 12 mm spacings between flexible light cables or parts of light cables.

3. Do not route the cord or flexible light cable through walls, doors, windows or any like part of the building structure.

4. Do not use if there is any damage to the light or cord insulation. Inspect periodically.

5. Do not submerge flexible light in liquids.6. Secure this flexible light cable using only the hangers, tracks

or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation.

7. DO NOT EXCEED THE MAXIMUM NUMBER OF EXTENSIONS OR FLEXIBLE LIGHT LENGTHS PERMITTED BY THE MARKING.

8. Do not install on gates or doors, where subject to flexing9. Do not install in cabinets, tanks or enclosures of any kind For Outdoor Installations:10. Caution: Ground Fault Circuit Interrupter (GFCI) protection

should be provided on the circuit or outlet.11. Caution: Use only outdoor extension cords, such as type SOW,

STW, SJOW or SJTW.12. Caution: Do not install closer than 3 meters from a swimming

pool surface13. All 120 Volt electrical connections to power supplies (drivers)

should be carried out by a qualified electrician. Power supplies used for outdoor applications must be enclosed in approved outdoor enclosure unless listed for wet locations.

14. Magic Lite offers a variety of power supplies for powering Micro LED Light Cable to suit your particular project. Power supplies vary in wattage rating and therefore will power various lengths of Micro LED Light Cable. Consult the list of power supplies in these instructions which indicate TOTAL FOOTAGE OF PRODUCT that each power supply will power. NEVER EXCEED THE MAXIMUM ALLOWABLE SINGLE RUN OF PRODUCT. Note that dimming power supplies have both maximum and minimum loads. Be sure to adhere to these restrictions when using dimmable power supplies.

INSTALLATIONDISCONNECT POWER BEFORE INSTALLING MICRO LED1. CONNECTING MICRO LED LIGHT CABLE TO POWER. Magic Lite Ltd MICRO LED LIGHT CABLE runs on 24 volt power

supply. Use only power supplies from Magic Lite Ltd. approved for use with Micro LED.

Use only extension segments and power cords provided by Magic Lite Ltd. for powering or extending Micro LED.

Make sure all end caps and connections are firmly seated to preclude the entry of water.

BE SURE TO MATCH POLARITY MARKINGS. 4. MOUNTING ACCESSORIES FOR MICRO LED LIGHT CABLE

USE OF MOUNTING ACCESSORIES

A) Cut Light Cable to desired length (nearest cutting line) with sharp knife or cable cutters. (Figure A) Refer to maximum lengths in specifications shown above. Do not exceed maximum recommended length of light cable. Do not exceed total wattage rating of power supply being used

B) Line up positive and negative polarity markings on male connector with markings on light cable. Place male connector over cut end of light cable and push together firmly. (See figure B)

C) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable. (Figure B)

D) Connect to power supply connector making sure polarity markings are matched. (Figure C)

E) Place end cap over dead end of light cable. (Figure D)

F) Connect wires from connector to low voltage power supply.

G) Connect low voltage power supply to main power (120 volt). Note – 120 volt connections to low voltage power supply should be carried out by qualified electrician.

2. JOINING TWO PIECES OF MICRO LED LIGHT CABLE TOGETHER. CAUTION: When joining two pieces of Micro LED Light Cable

together, MAKE SURE COMBINED LENGTHS OF TWO PIECES DO NOT EXCEED 100 WATTS IN POWER CONSUMPTION. Do not exceed rated wattage of power supply

A) Disconnect from power supply.

B) Remove end cap from Light Cable (if applicable) (Figure E)

C) Line up positive and negative polarity markings on female part of inline connector with markings on light cable. Place connector over cut end of light cable and push together firmly. (Figure F)

D) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable.(Figure G)

E) Repeat steps C and D for male side of inline connector.

F) Line up positive and negative polarity marks on in line connectors and push together until flaps are locked together.(Figure H)

G) Note: IMPORTANT SAFETY PRECAUTION! Female side of inline connector should always be attached to the length of light cable that will be attached to power supply.

H) Place end cap over dead end of LED Light Cable. (Figure D)

3. USING SPECIAL CONNECTORS.

When using one of Magic Lite’s special connectors (MLS-EFSN, MLS-BFXN, MLS-BFTR, MLS-BFTD or MLS-BFLN) please follow steps A – E in step 2 above.

After completing steps A – E, connect special connector to inline connector by matching appropriate ends and pushing firmly together.

WARNING: RISK OF FIRE AND SHOCK

Warning: Risk of Fire and Shock 1. Do not cover this product as the covering may cause the flexible

light to overheat and melt or ignite.2. Do not operate with the flexible light tightly coiled. To prevent

overheating do not allow contact between flexible light cables and parts of light cables. Maintain at least 12 mm spacings between flexible light cables or parts of light cables.

3. Do not route the cord or flexible light cable through walls, doors, windows or any like part of the building structure.

4. Do not use if there is any damage to the light or cord insulation. Inspect periodically.

5. Do not submerge flexible light in liquids.6. Secure this flexible light cable using only the hangers, tracks

or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation.

7. DO NOT EXCEED THE MAXIMUM NUMBER OF EXTENSIONS OR FLEXIBLE LIGHT LENGTHS PERMITTED BY THE MARKING.

8. Do not install on gates or doors, where subject to flexing9. Do not install in cabinets, tanks or enclosures of any kind For Outdoor Installations:10. Caution: Ground Fault Circuit Interrupter (GFCI) protection

should be provided on the circuit or outlet.11. Caution: Use only outdoor extension cords, such as type SOW,

STW, SJOW or SJTW.12. Caution: Do not install closer than 3 meters from a swimming

pool surface13. All 120 Volt electrical connections to power supplies (drivers)

should be carried out by a qualified electrician. Power supplies used for outdoor applications must be enclosed in approved outdoor enclosure unless listed for wet locations.

14. Magic Lite offers a variety of power supplies for powering Micro LED Light Cable to suit your particular project. Power supplies vary in wattage rating and therefore will power various lengths of Micro LED Light Cable. Consult the list of power supplies in these instructions which indicate TOTAL FOOTAGE OF PRODUCT that each power supply will power. NEVER EXCEED THE MAXIMUM ALLOWABLE SINGLE RUN OF PRODUCT. Note that dimming power supplies have both maximum and minimum loads. Be sure to adhere to these restrictions when using dimmable power supplies.

INSTALLATIONDISCONNECT POWER BEFORE INSTALLING MICRO LED1. CONNECTING MICRO LED LIGHT CABLE TO POWER. Magic Lite Ltd MICRO LED LIGHT CABLE runs on 24 volt power

supply. Use only power supplies from Magic Lite Ltd. approved for use with Micro LED.

Use only extension segments and power cords provided by Magic Lite Ltd. for powering or extending Micro LED.

Make sure all end caps and connections are firmly seated to preclude the entry of water.

BE SURE TO MATCH POLARITY MARKINGS. 4. MOUNTING ACCESSORIES FOR MICRO LED LIGHT CABLE

USE OF MOUNTING ACCESSORIES

A) Cut Light Cable to desired length (nearest cutting line) with sharp knife or cable cutters. (Figure A) Refer to maximum lengths in specifications shown above. Do not exceed maximum recommended length of light cable. Do not exceed total wattage rating of power supply being used

B) Line up positive and negative polarity markings on male connector with markings on light cable. Place male connector over cut end of light cable and push together firmly. (See figure B)

C) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable. (Figure B)

D) Connect to power supply connector making sure polarity markings are matched. (Figure C)

E) Place end cap over dead end of light cable. (Figure D)

F) Connect wires from connector to low voltage power supply.

G) Connect low voltage power supply to main power (120 volt). Note – 120 volt connections to low voltage power supply should be carried out by qualified electrician.

2. JOINING TWO PIECES OF MICRO LED LIGHT CABLE TOGETHER. CAUTION: When joining two pieces of Micro LED Light Cable

together, MAKE SURE COMBINED LENGTHS OF TWO PIECES DO NOT EXCEED 100 WATTS IN POWER CONSUMPTION. Do not exceed rated wattage of power supply

A) Disconnect from power supply.

B) Remove end cap from Light Cable (if applicable) (Figure E)

C) Line up positive and negative polarity markings on female part of inline connector with markings on light cable. Place connector over cut end of light cable and push together firmly. (Figure F)

D) Screw threaded contacts of connector into light cable until tight and plastic part of connector is seated firmly against light cable.(Figure G)

E) Repeat steps C and D for male side of inline connector.

F) Line up positive and negative polarity marks on in line connectors and push together until flaps are locked together.(Figure H)

G) Note: IMPORTANT SAFETY PRECAUTION! Female side of inline connector should always be attached to the length of light cable that will be attached to power supply.

H) Place end cap over dead end of LED Light Cable. (Figure D)

3. USING SPECIAL CONNECTORS.

When using one of Magic Lite’s special connectors (MLS-EFSN, MLS-BFXN, MLS-BFTR, MLS-BFTD or MLS-BFLN) please follow steps A – E in step 2 above.

After completing steps A – E, connect special connector to inline connector by matching appropriate ends and pushing firmly together.

WARNING: RISK OF FIRE AND SHOCK

Warning: Risk of Fire and Shock 1. Do not cover this product as the covering may cause the flexible

light to overheat and melt or ignite.2. Do not operate with the flexible light tightly coiled. To prevent

overheating do not allow contact between flexible light cables and parts of light cables. Maintain at least 12 mm spacings between flexible light cables or parts of light cables.

3. Do not route the cord or flexible light cable through walls, doors, windows or any like part of the building structure.

4. Do not use if there is any damage to the light or cord insulation. Inspect periodically.

5. Do not submerge flexible light in liquids.6. Secure this flexible light cable using only the hangers, tracks

or clips provided. Do not secure this product or its cord with staples, nails, or like means that may damage the insulation.

7. DO NOT EXCEED THE MAXIMUM NUMBER OF EXTENSIONS OR FLEXIBLE LIGHT LENGTHS PERMITTED BY THE MARKING.

8. Do not install on gates or doors, where subject to flexing9. Do not install in cabinets, tanks or enclosures of any kind For Outdoor Installations:10. Caution: Ground Fault Circuit Interrupter (GFCI) protection

should be provided on the circuit or outlet.11. Caution: Use only outdoor extension cords, such as type SOW,

STW, SJOW or SJTW.12. Caution: Do not install closer than 3 meters from a swimming

pool surface13. All 120 Volt electrical connections to power supplies (drivers)

should be carried out by a qualified electrician. Power supplies used for outdoor applications must be enclosed in approved outdoor enclosure unless listed for wet locations.

14. Magic Lite offers a variety of power supplies for powering Micro LED Light Cable to suit your particular project. Power supplies vary in wattage rating and therefore will power various lengths of Micro LED Light Cable. Consult the list of power supplies in these instructions which indicate TOTAL FOOTAGE OF PRODUCT that each power supply will power. NEVER EXCEED THE MAXIMUM ALLOWABLE SINGLE RUN OF PRODUCT. Note that dimming power supplies have both maximum and minimum loads. Be sure to adhere to these restrictions when using dimmable power supplies.

INSTALLATIONDISCONNECT POWER BEFORE INSTALLING MICRO LED1. CONNECTING MICRO LED LIGHT CABLE TO POWER. Magic Lite Ltd MICRO LED LIGHT CABLE runs on 24 volt power

supply. Use only power supplies from Magic Lite Ltd. approved for use with Micro LED.

Use only extension segments and power cords provided by Magic Lite Ltd. for powering or extending Micro LED.

Make sure all end caps and connections are firmly seated to preclude the entry of water.

2) Screw threaded contacts of connector into LED eStrip until tight and plastic part of connector is seated firmly against product (Figure B).

3) Connect to power supply connector making sure polarity markings are matched (Figure C).

5) Repeat steps 3 and 4 for male side of inline connector.

6) Line up positive and negative polarity marks on inline connectors and push together until flaps are locked together (Figure H).

7) Note: IMPORTANT SAFETY PRECAUTION! Female side of inline connector should always be attached to the length of LED eStrip that will be attached to power supply.

8) Place end cap over dead end of LED eStrip and secure with a small amount of silicon glue.

USING SPECIAL CONNECTORS

When using one of NSL’s special connectors (LES-BFXN, LES-BFTR, LES-BFTD or LES-BFLN) please follow steps 1-5 above.

After completing steps 1-5, connect special connector to inline connector by matching appropriate ends and pushing firmly together.

To reduce the risk of fire, electrical shock, or injury to persons:

LED DRIVER SELECTION

Dimmable Min. Max. Low Power Non-Dimming Feet Feet

LES-24-65W (Indoor only) Non-Dimming 1 65LEDDR-24-120W Non-Dimming 1 120 TRE24L40DC Both 18 40TRE24L96DC Both 48 90

Dimmable Min. Max. High Power Non-Dimming Feet Feet

LES-24-65W (Indoor only) Non-Dimming 1 20LEDDR-24-120W Non-Dimming 1 42 TRE24L40DC Both 8 18TRE24L96DC Both 22 42

If you do not wish to dim the LED eStrip use any of the LED Drivers listed above and be careful to abide by the minimum and maximum load values listed above.

If you wish to dim the LED eStrip, use only the TRE24L40DC, or TRE24L96DC and a low voltage dimmer listed below. All dimmable LED Drivers have no minimum load when used with an appropriate dimmer, however, all dimmable LED Drivers are more efficient if specified as per the minimum and maximum load values listed above.

1. Our dimmable power supplies are dimmable with any standard MLV/Incandescent TRIAC (Leading edge) dimmer switches. Dimmer switches are to be installed on the input (120VAC) of the driver.

2. Carefully following the dimmer instructions, dimmable LED power supply instructions, and the NEC, wire dimmer between 120VAC power input and 24 Volt Direct Current dimmable LED power supply.

WARNING

Page 2: CUTTING LED eSTRIP ENERGIZING SYSTEM NOTE JOINING TWO ... · M) Make sure to disconnect the power before adding segments. N) Only use extension segments provided with the entire set

WIRING INSTRUCTIONS

Assure power is disconnected from LED eStrip.

1. Use only 18AWG wire of the following specifications: • For all interior applications use only our molded cords with “CL2” wire NSL model number LES-001-6CL,

LES-001-12CL, LES-STP-2CL, LES-STP-12CL. • For all outdoor applications, use only our molded cords

with “Direct Burial” wire, NSL Model numbers LES-001-6BR, LES-001-12BR, LES-STP-2BR, LES-STP-12BR.

2. First, make sure LED Driver is not receiving power in any way. Wire LED eStrip per these instructions, assure proper connection and polarity on all fittings and strain reliefs, and then apply 120VAC power to LED Driver.

3. Low voltage Power Cord can be shortened or lengthened by cutting to desired dimension and placing cut end/splice in power supply box or LMSII-001 junction box(es). Low voltage male/male extension cord can be shortened or lengthened by cutting to desired dimension and placing splice(s) in LMSII-001 junction box(es). CAUTION: All splices and connections are only allowed exterior to all walls or structural members.

4. Never exceed a total of 100 feet of power cords or step cords per single run of LED eStrip.

5. Do not try to adjust, fix, rewire, LED eStrip. In the unlikely event LED eStrip does not illuminate, check connections and wiring polarity first. If this does not work, send LED eStrip back for warranty replacement, if applicable.

NOTE: These products may represent a possible shock or fire hazard if improperly installed or attached in any way. Products should be installed in accordance with the owner’s manual, current local codes, and/or the current National Electrical Code (NEC).

INSTALLATIONINSTRUCTIONS

eStripTHE FIELD CUTTABLE FLEXIBLE

SOLUTION FOR LOW ENERGY

USAGE LINEAR LIGHTING

LED

SPECIFICATIONS

Electrical Rating 0.96 watts/ft, 40mA, 24VDC 2.2 watts/ft High Power model Max. Single Run 90 Feet, 40’ High Power model

Cutability Every 6” at scissor mark Average LED Life 35,000 hours at 70% illumination Mounting Surface Temperature Limits - 40F to +104F

PVC Color Clear LED Colors Warm White, Cool White, Amber, Red, Blue, Green

NatioNal Specialty lightiNg Wet Locations

Cove Lighting

Eave Lighting

Deck Lighting

Stairs

Under/Over Cabinet Lighting

Visual Merchandising

Exhibit Projects

Theatrical Projects

ACCESSORIES

CAUTION:READ AND FOLLOW ALLSAFETY INSTRUCTIONS

LED eSTRIP CABINET WIRING LED eSTRIP BURIAL WIRING

Required Wire: Romex Romex CL2 CL2 12/14 12/14 Power Step AWG AWG Cord Cord 6’ or 12’ 2’ or 12’

System Layout: 110VAC --------------> Low Voltage -----> 24VDC ---------------> LED ------------------> LED ----------> Dimmer Class 2 eStrip eStrip Dimmable LED Power Supply

DIMMING REMOTE POWER SUPPLY INSTALLATION FLOW CHART

Low Voltage CL2 Wire Interior to Walls or Structural Members

NOTE: If you Do Not want LED eStrip to dim, the above charts are modified to remove “Low Voltage Dimmer”, the power supply becomes “Non-Dimmable” LEDDR-24-120W. As always, check the current NEC and local building codes for acceptance of your application design.

Fixture stranded lead wire should never penetrate any wall. Fixture stranded lead wire may penetrate through cabinets with access doors to all interior spaces. Only the UL listed CL2 lead wire may penetrate walls allowing the power supply to be mounted in an adjacent room to the fixture application.

After assuring wiring is correctly installed as per all diagrams, +/- polarity is maintained throughout, and all terminal block screws are tightened, cover all terminal block connections with junction box covers and included screws. Mount junction box to surface using included double-sided tape and/or wood screws. Lead wires should be neatly affixed to mounting surface with WSC-004 wire screw clips.

LES-008

LES-005

LES-BFTD

LES-BFLN

LES-002

LES-BFTR

LES-BFXNLES-003-03Molded FemaleEnd Cap

LES-STEP-XXXStep cordCL2 or Burial2 ft or 12 ft

LES-001-XXXPower cordCL2 or Burial6 ft or 12 ft

LES-010Channel track

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

INSTALLATIONINSTRUCTIONS

Micro LED Light cabLE

MLI021V3.7-0312

ACCESSORIES FOR MICRO LED LIGHT CABLE

POWER SUPPLIES

Indoor, Non-dimmable LED DriverMLDR-20-24JB 24V, 20W, hardwire Max 13’ G, B, WH, WW; Max 22’ R, A in junction boxOutdoor, Non-dimmable LED DriverMLDR-120-24 24V, 120W, hardwire Max 75’ G, B, WH, WW per single

secondary tap, max total 100’ combined two secondary taps Max 125’ R, A per single secondary tap, max total 150’ combined two secondary taps.

Outdoor, Dimmable LED DriverMLDR-20-24-DM 24V, 20W, hardwire Max 15’ G, B, WH, WW; Max 25’ R, A Max 18W, Min 10W Min 8’ G, B, WH, WW; Min 13’ R, AMLDR-40-24-DM 24V, 40W, hardwire Max 30’ G, B, WH, WW; Max 50’ R, A Max 36W, Min 20W Min 16’ G, B, WH, WW; Min 26’ R, AMLDR-60-24-DM 24V, 60W, hardwire Max 45’ G, B, WH, WW; Max 75’ R, A Max 54W, Min 30W Min 25’ G, B, WH, WW; Min 41’ R, AMLDR-100-24-DM 24V, 100W, hardwire Max 75’ G, B, WH, WW; Max 125’ R, A Max 90W, Min 50W Min 41’ G, B, WH, WW; Min 69’ R, A

SPECIFICATIONS FOR MICRO LED LIGHT CABLE

Dimensions: 6 X 12 mm (0.25” X 0.5”)

PVC body colour: Clear

LED spacing 25.4 mm (1”) Note custom spacing available upon request

Colours: Amber, Red, Blue, Green, White, Warm White

Voltage: 24 volt

2526 Speers Road, Unit 4 - 9 Oakville, Ontario, Canada L6L 5M2

Tel: 905-825-9592 • Out of Area: 1-888-945-5483 • Fax: 905-825-8334www.magiclite.com

APPROvED DIMMERS FOR DIMMABLE DRIvERS

Lutron Ariadni Dimmer AYLV-603P AYLV-603P-CSA AYLV-603P-S AYLV-600P AYLV-600P-CSA AYLV-600P-SLutron vareo DimmerV-1000 V-600 V-1000-S V-600-S VETN-1000 VETS-1000 VETS-1000-CSA VETN-1000-S VETS-1000-S VETS-R VETS-R-S VETS-1000-SL VETS-1000-SL-S VETS-A-SL VETS-A-SL-SLutron Nova DimmerNTLV-1000 NTLV-1500 NTLV-600 NTLV-1500-S NTLV-600-S NTLV-1000-S NTLV-1503P NTLV-2003P NTLV-1003P NTLV-603P NTLV-1503P-CSA NTLV-1003P-CSA NTLV-603P-CSA NTLV-1503P-S NTLV-2003P-S NTLV-1003P-S NTLV-603P-S NT-3PS NT-3PS-CSA NT-3PS-S NT-4PS NT-4PS-CSA NT-4PS-S NT-1PS NT-1PS-CSA NT-1PS-S Lutron Ceana DimmerCNLV-603P CNLV-600P Lutron Diva DimmerDVLV-103P DVLV-603P DVSCLV-103P DVSCLV-603P DVLV-103P-CSA DVLV-603P-CSA DVLV-103P-S DVLV-603P-S DVLV-103PH-S DVLV-603PH-S DVSCLV-103P-L DVSCLV-603P-L DVLV-600P DVLV-10P DVSCLV-10P DVSCLV-600P DVLV-10P-CSA DVLV-10P-S DVLV-10PH-S DVSCLV-10P-L SC-3PS SC-3PS SC-4PS SC-4PS SC-1PS SC-1PS SC-3PSNL SC-4PSNL SC-1PSNL Lutron Glyder DimmerGLV-600 GLV-600-CSA Lutron Lyneo DimmerLXLV-103PL LXLV-603PL LXLV-10PL LXLV-600PL Lutron Nova T DimmerNTLV-1500 NTLV-1000 NTLV-1000-277 NTLV-600 NTLV-600-277 Lutron Skylark DimmerSLV-603P SLV-603P-CSA SLV-603PH-CSA SLV-600P SLV-600P-CSA SLV-600PH-CSALeviton Illumatech DimmerIPM06-1LZ IPM06-1LX IPM10-1LZLeviton Mural DimmerMDM06-1LI MDM06-1LW MDM06-1LA MDM10-1LI MDM10-1LW MDM10-1LALeviton SureSlide Dimmer6613-PLT 6613-PLI 6613-PLW 6613-PLA Leviton ToggleTouch DimmerTGM10-1LI TGM10-1LI TGM10-1LA TGM10-1LT Leviton vizia DimmerVPM06-1LZ

Applications

Building Outlines

Coves

Stairway and aisle lighting

Signage

Backlit panels

Decks

Edge lit glow

Emergency lighting

Pathway lighting

Billboards

Highlighting architectural features

Over/Under cabinets

Decks & Patios

LES-003-2Push-On Female End Cap

LED eStrip

Wall

CL2 Wire

Class 2 Power Supply

CL2 wire allows thru-wall penetration for optimal remote Class 2 Power Supply installation

LED eStrip

Wall

Burial Wire

Class 2 Power Supply

Burial wire allows outdoor in-ground use for optimal remote Class 2 Power Supply installation

NatioNal Specialty lightiNgArchitecturAl And decorAtive lighting