247 Wiener Tierärztliche Monatsschrift Veterinary Medicine Austria 100 (2013) From the Department of Primatology, Max Planck Institute for Evolutionary Anthropology, Leipzig, Germany LC-MS as a method for non-invasive measurement of steroid hormones and their metabolites in urine and faeces of animals R. MURTAGH*, V. BEHRINGER and T. DESCHNER received April 8, 2013 accepted July 5, 2013 Keywords: review, steroid hormones, bio-fluids, non-invasive sampling, LC-MS. Summary This review presents the technique of liquid chromatography-mass spectrometry (LC-MS). It briefly outlines how LC-MS works, its different func- tions, the different types of instruments available, the applications with which it is mainly used and the costs involved. In particular, it highlights the effective- ness of LC-MS in measuring steroids and empha- sizes its usefulness in measuring steroids non- invasively in animals, from matrices such as urine and faeces. The advantages and disadvantages of LC-MS in comparison to other methods of steroid analysis such as immunoassays and gas chromato- graphy-mass spectrometry (GC-MS) are discussed. Schlüsselwörter: Review, Steroidhormone, biologi- sche Flüssigkeiten, nicht invasive Bestimmung, LC-MS. Zusammenfassung LC-MS als eine Methode zur nicht invasiven Messung von Steroiden in Urin und Kot von Tieren Dieser Übersichtsartikel gibt eine Zusammenfas- sung über die Technik der Flüssigchromatographie gekoppelt mit Massenspektrometrie (LC-MS). Er be- inhaltet eine kurze Einführung in die LC-MS und eine detaillierte Beschreibung über deren Funktionalität. Dabei wird auf die verschiedenen Instrumente ein- gegangen, die derzeit für LC-MS verwendet werden, sowie auf die entstehenden Kosten und die Gebiete, in denen diese Technik Anwendung findet. Beson- ders werden die Aspekte einer Steroidmessung mit- tels LC-MS angesprochen. Betont wird hierbei der vorteilhafte Einsatz der LC-MS für die nicht invasive Messung von Steroiden aus Urin und Kot. Des Wei- teren werden die Vor- und Nachteile besprochen, die eine Steroidmessung mit der LC-MS gegenüber ei- ner Analyse mittels immunologischer Methoden oder GC-MS hat. Introduction LC-MS is an instrumental method that combines the separation capabilities of a high performance liquid chromatography (HPLC) system with those of a conjoined mass spectrometer. Applications of LC-MS LC-MS has a broad range of applications across many different fields, including the petroleum indus- try (HSU et al., 2000), metabolomics (KOTLOWSKA, 2012), proteomics (AEBERSOLD and MANN, 2003), pesticide control (MATTERN et al., 1991), food safety (NÚÑEZ et al., 2005), clinical and forensic toxicology (MAURER, 2005, 2007), clinical diagnosis (RASHED, 2001; SHACKLETON, 2010), doping control (THEVIS and SCHÄNZER, 2007; SHEN et al., 2009) and phar- macokinetics (BEAUDRY et al., 1998). The usefulness of LC-MS in (steroid) hormone ana- lysis of animals has become very well known over the past decade. For example, LC-MS is widely used in the livestock industry for the detection of illegal growth hormones such as clenbuterol and other beta agonists, which contribute to health risks in consu- mers (BLANCA et al., 2005). Other studies describe methods developed for LC-MS to determine levels of synthetic corticosteroids in bovine urine (VAN POUCKE and VAN PETEGHEM, 2002; TÖLGYESI et al., Abbreviations: APCI = atmospheric pressure and chemical ionization; EIA = enzyme immunoassay; ESI = electro-spray ionization; GC-MS = gas chromatography - mass spectro- metry; HPLC = high performance/pressure liquid chromato- graphy; HRMS = high resolution mass spectrometry; LC- MS = liquid chromatography - mass spectrometry; MS/MS = tandem mass spectrometry; OQ/PQ = operational qualifi- cation/performance qualification; RIA = radioimmunoassay; SPE = solid phase extraction; ToF = time of flight; UPLC = ultra performance liquid chromatography

Upload: others

Post on 18-Apr-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

247

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

From the Department of Primatology, Max Planck Institute for Evolutionary Anthropology, Leipzig, Germany

LC-MS as a method for non-invasive measurement of steroid hormones and their metabolites in urine andfaeces of animals

R. MURTAGH*, V. BEHRINGER and T. DESCHNER

received April 8, 2013accepted July 5, 2013

Keywords: review, steroid hormones, bio-� uids, non-invasive sampling, LC-MS.

Summary

This review presents the technique of liquidchromatography-mass spectrometry (LC-MS). It brie� y outlines how LC-MS works, its different func-tions, the different types of instruments available, the applications with which it is mainly used and the costs involved. In particular, it highlights the effective-ness of LC-MS in measuring steroids and empha-sizes its usefulness in measuring steroids non-invasively in animals, from matrices such as urine and faeces. The advantages and disadvantages ofLC-MS in comparison to other methods of steroid analysis such as immunoassays and gas chromato-graphy-mass spectrometry (GC-MS) are discussed.

Schlüsselwörter: Review, Steroidhormone, biologi-sche Flüssigkeiten, nicht invasive Bestimmung, LC-MS.

Zusammenfassung

LC-MS als eine Methode zur nicht invasivenMessung von Steroiden in Urin und Kot von Tieren

Dieser Übersichtsartikel gibt eine Zusammenfas-sung über die Technik der Flüssigchromatographie gekoppelt mit Massenspektrometrie (LC-MS). Er be-inhaltet eine kurze Einführung in die LC-MS und eine detaillierte Beschreibung über deren Funktionalität. Dabei wird auf die verschiedenen Instrumente ein-gegangen, die derzeit für LC-MS verwendet werden, sowie auf die entstehenden Kosten und die Gebiete, in denen diese Technik Anwendung � ndet. Beson-ders werden die Aspekte einer Steroidmessung mit-tels LC-MS angesprochen. Betont wird hierbei der vorteilhafte Einsatz der LC-MS für die nicht invasive Messung von Steroiden aus Urin und Kot. Des Wei-teren werden die Vor- und Nachteile besprochen, die eine Steroidmessung mit der LC-MS gegenüber ei-ner Analyse mittels immunologischer Methoden oder GC-MS hat.

IntroductionLC-MS is an instrumental method that combines

the separation capabilities of a high performanceliquid chromatography (HPLC) system with those of a conjoined mass spectrometer.

Applications of LC-MS

LC-MS has a broad range of applications across many different � elds, including the petroleum indus-try (HSU et al., 2000), metabolomics (KOTŁOWSKA, 2012), proteomics (AEBERSOLD and MANN, 2003), pesticide control (MATTERN et al., 1991), food safety (NÚÑEZ et al., 2005), clinical and forensic toxicology (MAURER, 2005, 2007), clinical diagnosis (RASHED,

2001; SHACKLETON, 2010), doping control (THEVIS and SCHÄNZER, 2007; SHEN et al., 2009) and phar-macokinetics (BEAUDRY et al., 1998).

The usefulness of LC-MS in (steroid) hormone ana-lysis of animals has become very well known over the past decade. For example, LC-MS is widely used in the livestock industry for the detection of illegal growth hormones such as clenbuterol and other beta agonists, which contribute to health risks in consu-mers (BLANCA et al., 2005). Other studies describe methods developed for LC-MS to determine levels of synthetic corticosteroids in bovine urine (VANPOUCKE and VAN PETEGHEM, 2002; TÖLGYESI et al.,

Abbreviations: APCI = atmospheric pressure and chemical ionization; EIA = enzyme immunoassay; ESI = electro-spray ionization; GC-MS = gas chromatography - mass spectro-metry; HPLC = high performance/pressure liquid chromato-graphy; HRMS = high resolution mass spectrometry; LC-MS = liquid chromatography - mass spectrometry; MS/MS = tandem mass spectrometry; OQ/PQ = operational quali� -cation/performance quali� cation; RIA = radioimmunoassay; SPE = solid phase extraction; ToF = time of � ight; UPLC = ultra performance liquid chromatography

Page 2: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

248

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

2010). Performance-enhancing drugs in race horses and other equine athletes can be detected with amethod for measuring anabolic steroids in the serum of horses (LIU et al., 2011). Misuse of testosterone for doping purposes in human athletes can be deter-mined by the simultaneous measurement of testo-sterone and its isomer epitestosterone in urine with LC-MS (THEVIS and SCHÄNZER, 2007; DANACEAU et al., 2008). LC-MS became the method of choice in these research areas as it has the highest speci� city.

Principle of LC-MS

HPLC separates compounds according to their po-larity, resulting in different retention times on a statio-nary phase such as a silica-packed column (MEYER, 2010). In brief, the compounds are eluted from the column via a liquid (mobile) phase. Different com-pounds vary in their af� nities to the stationary phase of the column and the mobile phase leading to diffe-rent retention times (Fig. 1). Compounds differing in polarity elute at different times, with unpolar substan-ces eluting � rst when silica-packed columns are used. If elution is carried out with an isocratic system, consisting of only one mobile phase, elution times can be unacceptably long, complicating the detec-tion of later compounds as peaks become smaller and broader. Alternatively, a gradient elution can be applied whereby a second mobile phase of opposite polarity is added to the system. The main purpose of gradient elution is to move strongly retained compo-nents of the mixture faster by slowly mixing the mo-bile phases, changing the eluent from polar to non-polar or vice versa. In the case of a reversed-phase column, as on an isocratic system, substances elute in order of decreasing polarity when the mobile phase is gradually changed from polar to less polar. Using elution gradients can improve peak form as well as shorten run times.

The compounds are then transferred via a � ow of solvent to the MS, where they are further separated

according to their mass/charge ratio (DE HOFFMANN, 2005). The solvent is vapourized in a heated spray chamber as it enters the MS. Vapour is transported through the chamber via a � ow of carrier gas (e.g.nitrogen) and then bombarded by an electron beam, which ionizes the analytes within. Ions are created either by transferring an electron to an analyte (for-ming a negatively charged ion) or by causing one to be lost (forming a positively charged ion). The ions are transported through a vacuum to the mass analyser, where electro-magnetic forces differentiate them by their mass and charge state. The information is passed into a detector and a mass spectrum is pro-duced. Ions are eventually neutralized, by colliding with the MS walls and collecting electrons, and re-moved from the instrument by a vacuum pump. The technique is very sensitive and has a high dynamic range of measurement, up to four orders of magni-tude. In combination, HPLC and MS separation me-chanisms offer a very high compound speci� city and enable the simultaneous measurement of a large number of substances.

Using MS/MS (tandem mass spectrometry) further increases the speci� city of a method. Not only is the target analyte measured but in addition its precursor ion is transferred to a chamber in the MS where it is bombarded with a collision gas (e.g. argon, nitrogen or xenon) and fragmented into product ions (Fig. 2), the mass of which is then read in the detector. This allows the identi� cation of structural isomers that dis-play similar chromatographic behaviour in the HPLC column and that produce similar ions in the MS, as different target analytes give different product ions when fragmented.

For example, the cortisol metabolite tetrahydro-cortisol and its isomer allotetrahydrocortisol share a common retention time on a HPLC column. They also share a common molar mass and therefore the same precursor ion mass when ionized. With MS/MS, the precursor ion of each of the isomers fragments into

Fig. 1: Elution of substances at different retention times from a reverse-phase HPLC column. In such a system substances elute in order of decreasing polarity.

Fig. 2: Schematic pathway of the MS/MS process from analyte ionization, to parent ion formation, to fragmentation into product ions, to detection.

Page 3: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

249

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

different product ions, which allows them to be distin-guished from each other. The most abundant product ion mass for tetrahydrocortisol is 301.15 m/z, whereas for allotetrahydrocortisol it is 331.15 m/z (Fig. 3).

Instrumentation

In recent years, there has been a tendency to re-place standard HPLC instruments with ultra perfor-mance liquid chromatography (UPLC) systems that, like HPLC, can be conjoined to all types of MS (SWARTZ, 2005). In contrast to HPLC, these systems are designed to work with microbore® columns, which can withstand higher pressures leading to faster � ow rates and elution times and shorter run times. Faster separations reduce solvent amounts and running costs. However, most standard HPLC instruments are also capable of attaining the higher pressures and � ow rates required for microbore® columns.

Similarly, MS interfaces that are responsible for the desolvation and ionization of the analytes have be-come increasingly sophisticated. There are two main types of source interface:

1. electro-spray ionization (ESI) is more commonly used and is better suited to ionizing polar compounds such as steroid hormones (DEVENTER et al., 2006).

2. atmospheric pressure chemical ionization (APCI) is used to measure thermally stable, less polar sub-stances such as some hydrocarbons (MARVIN et al., 1999).

MS instruments can be divided into two main types: MS (e.g. quadrupoles and ion traps) and high resolu-tion mass spectrometry (HRMS, e.g. LC-MS time of � ight (ToF) and orbitrap). The principle difference be-tween these instruments is that MS separates ions

via electro-magnetic forces in a mass analyser,whereas HRMS separates ions via their acceleration through a � ight tube. For example, LC-MS ToFmeasures the mass/charge ratio of an ion via the time it takes it to reach the detector. MS instruments can only scan for a target range of masses, whereas HRMS instruments can scan for masses of bothtarget and non-target substances. MS instruments such as quadrupoles are currently more sensitive and therefore mainly used for quantitative analysis but HRMS instruments, which are mainly used for quali-tative purposes, are catching up. There are already HRMS instruments available that allow for higher re-solution and sensitivity (WU et al., 2012).

Steroid hormones and LC-MS

Measuring steroid hormones is of huge importance to investigating stress levels in the � elds of animalwelfare (MÖSTL and PALME, 2002) and behavioural ecology, where steroid hormones in� uence animal behaviour and vice versa (DUFTY et al., 2002; GODWIN et al., 2002; WINGFIELD et al., 2006; ANESTIS, 2011).

Steroids comprise a wide group of natural andsynthetic organic compounds that share a similar chemical structure of 17 carbon atoms arranged in a four-ring system. They are largely produced in speci-� c glands such as the ovaries, testes and the adrenal cortex (BORON and BOULPAEP, 2009). They areinvolved in a variety of endocrinological functions ranging from metabolism and digestion to thedevelopment and functioning of the sexual organs and include the sterols, bile acids, corticosteroids (glucocorticoids and mineralcorticoids) and the sex steroids (progestogens, androgens and oestrogens;

Fig. 3: A = screenshot of the two most abundant product ions of tetrahydrocortisol. B = screenshot of the two most abundant product ions of allotetrahydrocortisol. a, compound name; b, peak retention time; c, peak area; d, peak height; e, ionization mode; f, product ion trace (precursor ion mass > product ion mass).

Page 4: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

250

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

GOMES et al., 2008). Steroid hormones are present in their active form mainly in the blood, metabolized in the liver and kidney and excreted via urine and faeces in a multitude of modi� ed, inactive forms that can be conjugated to substances such as glucuronides and sulphates. However, the metabolites of a steroidhormone in urine or faeces can originate from diffe-rent sources. For example, while testosterone islargely produced in the testes, the testosterone meta-bolites that are abundant in urine can also derive from the adrenal glands. Therefore, if researchers areprimarily interested in testicular function it is unwise to rely on the concentration of metabolites that also originate in the adrenal glands (HAUSER et al., 2011).

An LC-MS can be used to develop methods to measure either conjugated or non-conjugated forms of steroid hormone metabolites, as required. A large number of steroid conjugates are possible. Often it is preferable to measure the de-conjugated form than to measure all possible conjugated forms. Themeasurement of conjugated steroids can be more complex due to the different ionization properties of conjugated steroids. In-source dissociation ofglucuronides from steroids, for example, canpotentially interfere with accurate determinations (KAKLAMANOS et al., 2009). Furthermore, reference standards used to identify and quantify the target analyte are not always available for some conjugated forms. Care must be taken to ensure that chemical de-conjugation does not lead to degradation and/or transformation of the target analyte (HAUSER et al., 2008a).

Non-invasive measurement of hormones inanimals

Blood collection from animals, especially wildanimals, is highly invasive and dif� cult to perform and can be very stressful for the animal (WILSON et al., 1978; BEERDA, 1996). It has become increasingly im-portant to develop methods to measure steroidhormones in samples obtained non-invasively. Over the last few decades there has been increasedresearch into enzyme immunoassay (EIA)-, radioimmunoassay (RIA)- and HPLC-based techniques (e.g. fraction collection) to measure hormones insamples from humans and domestic, wild and cap-tive animals. Examples include steroid hormone ana-lysis in the urine and faeces from livestock (PALME et al., 1996), faecal steroid analysis for monitoring repro-ductive status in farm, wild and zoo animals (SCHWARZENBERGER et al., 1996), analysis ofsalivary cortisol in squirrel monkeys (FUCHS et al., 1997), pregnancy determination in faecal samples from felids (DEHNHARD and JEWGENOW, 2013) and measurement of urinary reproductive hormones in captive apes (SHIMIZU et al., 2003). In addition,methods to analyse non-steroidal hormones such as oxytocin in the urine of chimpanzees (CROCKFORD

et al., 2013) and thyroid hormones in urine and faecal samples from birds and mammals have been de-scribed (WASSER et al., 2010). In wild chimpanzees, for example, urine samples (MULLER and LIPSON, 2003; EMERY THOMPSON, 2005; SOBOLEWSKI et al., 2012) and faecal samples (EMERY THOMPSON, 2005; MUEHLENBEIN, 2006) can easily be collected for the purpose of non-invasive study.

In addition to these immunoassay-based methods of quanti� cation, a number of LC-MS methods have been developed to measure steroid hormones and their metabolites in matrices obtained non-invasively, such as urine and faeces. This has been verybene� cial in clinical contexts (KRONE et al., 2010; LUTZ et al., 2006) as well as in the � eld of primatology (HAGEY and CZEKALA, 2003; HAUSER et al., 2008a; WELTRING et al., 2012).

Immunoassays versus LC/GC-MS

Immunoassays are based on the binding of a speci-� c antibody to an antigen of the target analyte (RAEM and RAUCH, 2007). The speci� city of any given assay depends on how exclusively the antibody binds to the target analyte. Cross-reactivity occurs when the anti-body of an assay also binds to other substances that are similar in their structure to the target analyte. Many potentially cross-reactive substances must be tested during the development of an assay. Most commercial assays are developed for a speci� c com-pound in serum. As the concentration of potentially confounding metabolites and/or degradation pro-ducts found in serum is generally rather low and tar-get analytes such as testosterone and cortisol are highly abundant, cross-reactivity does not play such an important part in these assays. However, inmatrices such as urine or faeces the metabolites are more abundant than the target analytes and so the potential confounding effects of cross-reactivities are dramatically increased (PREIS et al., 2011; WELTRING et al., 2012). Successful attempts to derive meaning-ful measurements of steroid hormones and theirmetabolites in matrices such as urine and faeces,despite the confounding effects of cross-reactive substances, have led to the use of validated group-speci� c assays (MÖSTL et al., 2005; PALME, 2005; HEISTERMANN et al., 2006) or a chromatographic separation of sample extracts prior to assay(ZIEGLER, 1996; MÖHLE et al., 2002).

LC-MS techniques do not suffer from problemsrelated to cross-reactivity. A high compound speci-� city is achieved by the combined separation based on speci� c characteristics in terms of polarity during liquid chromatography separation, as well as the mass/charge ratio of the parent ion in combination with the mass/charge ratio of fragments of the ana-lyte during MS and MS/MS separation steps. Agrowing number of studies point out the advantages of LC-MS compared to techniques such as EIA and

Page 5: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

251

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

RIA (ROSNER et al., 2006; FANELLI et al., 2011; KOAL et al., 2012).

Although they are less accurate and versatile,immunoassays have the bene� t of being faster and cheaper than LC-MS (RAUH, 2009; THIENPONT et al., 2008). An additional advantage is that there is no need to develop methods, as many commercial assays for many different hormones already exist. However,the application of an assay in a species or matrixother than the one for which it was developednecessitates careful validation (PALME, 2005). LC-MS can be used to estimate the degree of inter-ference by cross-reactivity and therefore can have an important role in the analytical validation of EIA or RIA for speci� c hormones in a variety of matrices(KUTSUKAKE et al., 2009; BEHRINGER et al., 2012; PREIS et al., 2011). LC-MS can be used to ensure that assays reliably measure the target analyte. Whatever method is used, a thorough physiological validation is mandatary to ensure that the measured steroids re-� ect something biologically meaningful (PALME, 2005).

LC-MS allows the simultaneous measurement of several hormones and metabolites in any givensample, leading to high throughput capabilities. This renders the method particularly interesting for studies where a number of metabolites are of interest(HAUSER et al., 2011; KOAL et al., 2012; KUTSUKAKE et al., 2009; PREIS et al., 2011; SURBECK et al., 2012a,b). Particularly interesting for behaviouralendocrinology research is a method that allows the simultaneous measurement of 23 steroid hormones and their metabolites in small volumes of urinecollected non-invasively from wild primates (HAUSER et al., 2008a).

Another method of chromatographic separation in connection with mass spectrometry is GC-MS. The detection principle is similar to that of LC-MS, using the mass fragments that result from ionization of the molecules. Before analysis, analytes of interest must be extracted from the matrix into a liquid solventphase. The extract is injected into the GC where it is swept onto a separation column by an inert carrier gas. The analytes in the mixture are carried through the column by the carrier gas and separated from one another by virtue of their interaction with the coating (stationary phase) on the inside wall of the column. Each analyte interacts with the stationary phase at different rates, resulting in different retention times. In the case of steroids, derivatization is necessary as GC-MS requires volatile substances. In contrast, LC-MS does not require a lengthy derivatization that could result in analyte losses (GOMES et al., 2009). Nonetheless, GC-MS has the advantage thatfragmentation patterns of substances can be repro-duced. The patterns are instrument independent,allowing databases and libraries to be created and shared between users (HALKET, 2004). Furthermore, internal standards can be used to monitor ef� ciency

of derivatization so that, once produced, a calibration curve can be used repeatedly. This is in contrast to the situation in LC-MS, where ion suppression can occur with ESI or APCI so a new standard curve has to be created for each sequence of samples (WUDY and HARTMANN, 2004).

Before hormone analysis of bio-� uids with LC-MS, sample clean-up is essential to remove unwanted matrix compounds that could potentially affect the measurements. Often solid phase extraction (SPE) is employed. Depending on whether the study isinterested in measuring conjugated or unconjugated forms of metabolites, further steps may also be re-quired, such as hydrolysis or solvolysis procedures (HAUSER et al., 2008b). Although extraction pro-cedures can be time consuming, the sensitivity and reliability of LC-MS instruments is constantly in-creasing with the development of new instruments and thus it is highly likely that less time will need to be spent on clean-up procedures in the future.

There are a few other disadvantages when it comes to using LC-MS, including the two most common complaints, matrix effects and ionization issues. The matrix effect is interference from molecules in the sample that cannot be removed during the clean-up steps. Unwanted matrix can cause ion suppression or enhancement and ultimately interfere with the quanti-� cation of analytes (VAN EECKHAUT et al., 2009). However, this can usually be controlled for with the use of synthetic hormones as internal standards,something that cannot be done with EIA or RIA.

Costs of measuring hormones via LC-MS

The cost of new LC-MS instruments ranges from€ 100,000 to more than € 600,000. Costs depend on the features, such as whether an HPLC or UPLCsystem is required, the presence of on-line extrac-tions, the type of MS interface, ionization mode,sensitivity and detection limits. In addition to theinitial purchase cost, machines require an annual operational quali� cation and performance quali� -cation (OQ/PQ) and maintenance work, which areoften performed by an external company, usually the vendor of the instrument. Maintenance contractscurrently cost roughly € 10,000 per year, including an annual OQ/PQ visit and year-round technicalsupport. Contracts are recommended as there can be frequent troubleshooting involved for instrument upkeep. However, with quali� ed personnel much of the work can be carried out in-house, greatlyreducing the costs. It is estimated in our endocrino-logy laboratory that analysis of one analyte per urine/faecal sample costs an average of € 15. The � gure includes consumables, reagents, extraction costs, hydrolysis (urine only), solvolysis, LC-MS analysis, equipment maintenance contracts and personnel costs. It is evident that LC-MS is only cost-ef� cient when multiple compounds per sample are analysed

Page 6: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

252

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

and when the machine is frequently in operation, i.e. it is used for routine analysis.

The level of training and expertise varies amongst personnel working with LC-MS. System operation and data analysis can be carried out by anyone with a reasonable amount of training. Maintenance of theinstruments and troubleshooting requires the tech-nical, mechanical and electronic skills of a scientist/engineer. Interpretation of data and the development of methods requires in-depth knowledge of bothorganic and inorganic chemistry.

Conclusion

LC-MS can be very useful for the measurement of hormones obtained non-invasively in a variety ofmatrices from many different species. Furthermore, it can be used for the analytical validation of othermeasurement techniques such as EIA and RIA. The advantages of speci� city and the ability to perform

simultaneous measurements can outweigh itsbiggest disadvantage, which is its cost, whenmultiple substances are routinely analysed persample. The continual development of instruments hints at an exciting future in metabolite analysisacross many � elds of research.

AcknowledgmentsThe authors gratefully appreciate invaluable input from Anja Weltring and two anonymous reviewers. We thank Carolyn Rowney for editing the manuscript and acknowledge all the help and support from the endocrinology group in the Primatology Department of the Max Planck Institute for Evolutionary Anthro-pology in Leipzig. We especially thank RupertPalme for the invitation to participate in the ISWE Conference in Vienna and for his support with this manuscript.

ReferencesAEBERSOLD, R., MANN, M. (2003): Mass spectrometry-

based proteomics. Nature 422, 198–207.ANESTIS, S.F. (2011): Primate personality and behavioral

endocrinology. In: WEISS, A., KING, J.E., MURRAY, L. (eds.): Personality and temperament in nonhuman prima-tes. Springer New York, p. 169–192.

BEAUDRY, F., YVES LE BLANC, J.C., COUTU, M., BROWN, N.K. (1998): In vivo pharmacokinetic scree-ning in cassette dosing experiments: the use of on-lineprospekt® liquid chromatography/atmospheric pres-sure chemical ionization tandem mass spectrometry technology in drug discovery. Rapid Commun Mass Spectrom 12, 1216–1222.

BEERDA, B. (1996): The use of saliva cortisol, urinary corti-sol, and catecholamine measurements for a noninvasive assessment of stress responses in dogs. Horm Behav 30, 272–279.

BEHRINGER, V., HOHMANN, G., STEVENS, J.M.G., WELT-RING, A., DESCHNER, T. (2012): Adrenarche in bono-bos (Pan paniscus): evidence from ontogenetic changesin urinary dehydroepiandrosterone-sulfate levels. JEndocrinol 214, 55–65.

BLANCA, J., MUÑOZ, P., MORGADO, M., MÉNDEZ, N., ARANDA, A., REUVERS, T., HOOGHUIS, H. (2005):Determination of clenbuterol, ractopamine andzilpaterol in liver and urine by liquid chromatography tandem mass spectrometry. Anal Chim Acta 529,199–205.

BORON, W.F., BOULPAEP, E.L. (2009): Medical physiolo-gy: a cellular and molecular approach (2nd Int. ed.), Saun-ders/Elsevier, Philadelphia.

CROCKFORD, C., WITTIG, R.M., LANGERGRABER, K., ZIEGLER, T.E., ZUBERBUHLER, K., DESCHNER, T. (2013): Urinary oxytocin and social bonding in related and unrelated wild chimpanzees. Proc Royal Soc B 280, 20122765.

DANACEAU, J.P., SCOTT MORRISON, M., SLAWSON, M.H. (2008): Quantitative con� rmation of testosterone and epitestosterone in human urine by LC/Q-ToF mass spectrometry for doping control. J Mass Spectrom 43, 993–1000.

DEHNHARD, M., JEWGENOW, K. (2013): Measurement of faecal prostaglandins in felids and three ursidspecies. Wien Tierärztl Monat – Vet Med Austria 100, 227–237.

DEVENTER, K., EENOO, P.V., DELBEKE, F.T. (2006): Scree-ning for anabolic steroids in doping analysis by liquid chromatography/electrospray ion trap mass spectro-metry. Biomed Chromatogr 20, 429–433.

DE HOFFMANN, E. (2005): Mass spectrometry. Kirk-Othmer Encyclopedia of Chemical Technology. JohnWiley & Sons, Inc. Hoboken, NJ, USA.

DUFTY, A.M., CLOBERT, J., MØLLER, A.P. (2002):Hormones, developmental plasticity and adaptation. Trends Ecol Evol 17, 190–196.

EECKHAUT, A. VAN, LANCKMANS, K., SARRE, S.,SMOLDERS, I., MICHOTTE, Y. (2009): Validation of bioanalytical LC-MS/MS assays: evaluation of matrixeffects. J Chromatogr B 877, 2198–2207.

EMERY THOMPSON, M. (2005): Reproductive endocri-nology of wild female Chimpanzees (Pan troglodytes schweinfurthii): methodological considerations and the role of hormones in sex and conception. Am J Primatol 67, 137–158.

FANELLI, F., BELLUOMO, I., LALLO, V.D. DI, CUOMO, G., IASIO, R. DE, BACCINI, M., CASADIO, E., CASETTA,B., VICENNATI, V., GAMBINERI, A., GROSSI, G.,PASQUALI, R., PAGOTTO, U. (2011): Serum steroid pro-� ling by isotopic dilution-liquid chromatography-mass spectrometry: Comparison with current immunoassays and reference intervals in healthy adults. Steroids 76, 244–253.

Page 7: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

253

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

FUCHS, E., KIRSCHBAUM, C., BENISCH, D., BIESER, A. (1997): Salivary cortisol: a non-invasive measure of hypo-thalamo-pituitary-adrenocortical activity in the squirrel monkey, Saimiri sciureus. Lab Anim 31, 306–311.

GODWIN, J., LUCKENBACH, J.A., BORSKI, R.J. (2002): Ecology meets endocrinology: environmental sexdetermination in � shes. Evol Development 5, 40–49.

GOMES, R.L., MEREDITH, W., SNAPE, C.E., SEPHTON, M.A. (2008): Conjugated steroids: analytical approaches and applications. Anal Bioanal Chem 393, 453–458.

GOMES, R.L., MEREDITH, W., SNAPE, C.E., SEPHTON, M.A. (2009): Analysis of conjugated steroid androgens: Deconjugation, derivatisation and associated issues. J Pharm Biomed Analysis 49, 1133–1140.

HAGEY, L.R., CZEKALA, N.M. (2003): Comparativeurinary androstanes in the great apes. Gen Comp Endo-crinol 130, 64–69.

HALKET, J.M. (2004): Chemical derivatization and mass spectral libraries in metabolic pro� ling by GC/MS and LC/MS/MS. J Exp Botany 56, 219–243.

HAUSER, B., DESCHNER, T., BOESCH, C. (2008a): Deve-lopment of a liquid chromatography-tandem mass spec-trometry method for the determination of 23 endogenous steroids in small quantities of primate urine. J Chro-matogr B 862, 100–112.

HAUSER, B., SCHULZ, D., BOESCH, C., DESCHNER, T. (2008b): Measuring urinary testosterone levels of the great apes - Problems with enzymatic hydrolysis using Helix pomatia juice. Gen Comp Endocrinol 158, 77–86.

HAUSER, B., MUGISHA, L., PREIS, A., DESCHNER, T. (2011): LC-MS analysis of androgen metabolites in serum and urine from east African chimpanzees (Pan troglody-tes schweinfurthii). Gen Comp Endocrinol 170, 92–98.

HEISTERMANN, M., PALME, R., GANSWINDT, A. (2006): Comparison of different enzyme immunoassays forassessment of adrenocortical activity in primates based on fecal analysis. Am J Primatol 68, 257–273.

HSU, C.S., DECHERT, G.J., ROBBINS, W.K., FUKUDA, E.K. (2000): Naphthenic acids in crude oils characterized by mass spectrometry. Energy Fuels 14, 217–223.

KAKLAMANOS, G., THEODORIDIS, G., DABALIS, T. (2009): Determination of anabolic steroids in bovine urine by liquid chromatography-tandem mass spectrometry. J Chromatogr B 877, 2330–2336.

KOAL, T., SCHMIEDERER, D., PHAM-TUAN, H., RÖHRING, C., RAUH, M. (2012): Standardized LC-MS/MS based steroid hormone pro� le-analysis. J Steroid Biochem Mol Biol 129, 129–138.

KOTŁOWSKA, A. (2012): Application of steroid hormone metabolomics in search of biomarkers in clinical re-search. Drug Development Res 73, 381–389.

KRONE, N., HUGHES, B.A., LAVERY, G.G., STEWART, P.M., ARLT, W., SHACKLETON, C.H.L. (2010): Gas chro-matography/mass spectrometry (GC/MS) remains apre-eminent discovery tool in clinical steroid investi-gations even in the era of fast liquid chromatographytandem mass spectrometry (LC/MS/MS). J SteroidBiochem Mol Biol 121, 496–504.

KUTSUKAKE, N., IKEDA, K., HONMA, S., TERAMOTO, M., MORI, Y., HAYASAKA, I., YAMAMOTO, R., ISHIDA, T., YOSHIKAWA, Y., HASEGAWA, T. (2009): Validation of salivary cortisol and testosterone assays in chimpanzees by liquid chromatography-tandem mass spectrometry. Am J Primatol 71, 696–706.

LIU, Y., UBOH, C.E., SOMA, L.R., LI, X., GUAN, F., YOU, Y., RUDY, J.A., CHEN, J.-W. (2011): Detection andcon� rmation of 60 anabolic and androgenic steroids in equine plasma by liquid chromatography-tandem mass spectrometry with instant library searching. Drug Testing Analysis 3, 54–67.

LUTZ, U., LUTZ, R.W., LUTZ, W.K. (2006): Metabolicpro� ling of glucuronides in human urine by LC-MS/MS and partial least-squares discriminant analysis for classi-� cation and prediction of gender. Anal Chem 78, 4564–4571.

MARVIN, C.H., SMITH, R.W., BRYANT, D.W., MCCARRY, B.E. (1999): Analysis of high-molecular-mass polycyclic aromatic hydrocarbons in environmental samples using liquid chromatography–atmospheric pressure chemi-cal ionization mass spectrometry. J Chromatogr A 863, 13–24.

MATTERN, G.C., LIU, C.H., LOUIS, J.B., ROSEN, J.D. (1991): GC/MS and LC/MS determination of 20 pesti-cides for which dietary oncogenic risk has been estima-ted. J Agri Food Chem 39, 700–704.

MAURER, H.H. (2005): Multi-analyte procedures for scree-ning for and quanti� cation of drugs in blood, plasma, or serum by liquid chromatography-single stage or tandem mass spectrometry (LC-MS or LC-MS/MS) relevant to cli-nical and forensic toxicology. Clin Biochem 38, 310–318.

MAURER, H.H. (2007): Current role of liquid chromatogra-phy-mass spectrometry in clinical and forensic toxico-logy. Anal Bioanal Chem 388, 1315–1325.

MEYER, V. (2010): Practical high-performance liquid chro-matography (5th ed.), John Wiley & Sons Ltd. Chichester, U.K.

MÖHLE, U., HEISTERMANN, M., PALME, R., HODGES, J.K. (2002): Characterization of urinary and fecal me-tabolites of testosterone and their measurement forassessing gonadal endocrine function in male nonhuman primates. Gen Comp Endocrinol 129, 135–145.

MÖSTL, E., PALME, R. (2002): Hormones as indicators of stress. Dom Anim Endocrinol 23, 67–74.

MÖSTL, E., RETTENBACHER, S., PALME, R. (2005):Measurement of corticosterone metabolites in birds’ droppings: an analytical approach. Ann NY Acad Sci 1046, 17–34.

MUEHLENBEIN, M.P. (2006): Intestinal parasite infections and fecal steroid levels in wild chimpanzees. Am J Phys Anthropol 130, 546–550.

MULLER, M.N., LIPSON, S.F. (2003): Diurnal patterns of urinary steroid excretion in wild chimpanzees. Am JPrimatol 60, 161–166.

NÚÑEZ, O., MOYANO, E.; GALCERAN, M.T. (2005): LC-MS/MS analysis of organic toxics in food. Trends Anal Chem 24, 683–703.

Page 8: LC-MS as a method for non-invasive measurement of steroid … · 2015-03-18 · 247 Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013) From the Department

254

Wiener Tierärztliche Monatsschrift – Veterinary Medicine Austria 100 (2013)

PALME, R., FISCHER, P., SCHILDORFER, H., ISMAIL, M.N. (1996): Excretion of infused 14C-steroid hormones viafaeces and urine in domestic livestock. Anim Reprod Sci 43, 43–63.

PALME, R. (2005): Measuring fecal steroids: guidelines for practical application. Ann NY Acad Sci 1046, 75–80.

PREIS, A., MUGISHA, L., HAUSER, B., WELTRING, A.,DESCHNER, T. (2011): Androgen and androgen meta-bolite levels in serum and urine of East African chim-panzees (Pan troglodytes schweinfurthii): Comparison of EIA and LC-MS analyses. Gen Comp Endocrinol 174, 335–343.

RAEM, A.M., RAUCH, P. (2007): Immunoassays. Elsevier Spektrum, München, Heidelberg.

RASHED, M.S. (2001): Clinical applications of tandem mass spectrometry: ten years of diagnosis and screen-ing for inherited metabolic diseases. J Chromatogr B 758, 27–48.

RAUH, M. (2009): Steroid measurement with LC-MS/MS in pediatric endocrinology. Mol Cell Endocrinol 301, 272–281.

ROSNER, W., AUCHUS, R.J., AZZIZ, R., SLUSS, P.M., RAFF, H. (2006): Utility, limitations, and pitfalls in measu-ring testosterone: an endocrine society position state-ment. J Clin Endocrinol Met 92, 405–413.

SCHWARZENBERGER, F., MÖSTL, E., PALME, R., BAM-BERG, E. (1996): Faecal steroid analysis for non-invasive monitoring of reproductive status in farm, wild and zoo animals. Anim Reprod Sci 42, 515–526.

SHACKLETON, C. (2010): Clinical steroid mass spectro-metry: A 45-year history culminating in HPLC-MS/MSbecoming an essential tool for patient diagnosis. JSteroid Biochem Mol Biol 121, 481–490.

SHEN, M., YAN, H., XIANG, P., SHEN, B. (2009): Simul-taneous determination of anabolic androgenic steroids and their esters in hair by LC-MS-MS. Chromatographia 70, 1381–1386.

SHIMIZU, K., UDONO, T., TANAKA, C., NARUSHIMA, E., YOSHIHARA, M., TAKEDA, M., TANAHASHI, A.,ELSACKAR, L. VAN, HAYASHI, M., TAKENAKA, O. (2003): Comparative study of urinary reproductivehormones in great apes. Primates 44, 183–190.

SOBOLEWSKI, M.E., BROWN, J.L., MITANI, J.C. (2012): Territoriality, tolerance and testosterone in wild chim-panzees. Anim Beh 84, 1469–1474.

SURBECK, M., DESCHNER, T., SCHUBERT, G.,WELTRING, A., HOHMANN, G. (2012a): Mate compe-tition, testosterone and intersexual relationships inbonobos, Pan paniscus. Anim Beh 83, 659–669.

SURBECK, M., DESCHNER, T., WELTRING, A.,HOHMANN, G. (2012b): Social correlates of variation in urinary cortisol in wild male bonobos (Pan paniscus). Horm Beh 62, 27–35.

SWARTZ, M.E. (2005): UPLCTM: an introduction and review. J Liq Chromatogr Relat Technol 28, 1253–1263.

THEVIS, M., SCHÄNZER, W. (2007): Current role ofLC–MS(/MS) in doping control. Anal Bioanal Chem 388, 1351–1358.

THIENPONT, L.M., UYTFANGHE, K. VAN, BLINCKO, S., RAMSAY, C.S., XIE, H., DOSS, R.C., KEEVIL, B.G., OWEN, L.J., ROCKWOOD, A.L., KUSHNIR, M.M., CHUN, K.Y., CHANDLER, D.W., FIELD, H.P., SLUSS, P.M. (2008): State-of-the-art of serum testosterone measurement by isotope dilution - liquid chromatography - tandem mass spectrometry. Clin Chem 54, 1290–1297.

TÖLGYESI, Á., SHARMA, V.K., KOVACSICS, L., FEKETE, J. (2010): Quanti� cation of corticosteroids in bovineurine using selective solid phase extraction and reversed-phase liquid chromatography/tandem mass spectro-metry. J Chromatogr B 878, 1471–1479.

VAN POUCKE, C., VAN PETEGHEM, C. (2002): Develop-ment and validation of a multi-analyte method for the detection of anabolic steroids in bovine urine with li-quid chromatography-tandem mass spectrometry. JChromatogr B 772, 211–217.

WASSER, S.K., AZKARATE, J.C., BOOTH, R.K.,HAYWARD, L., HUNT, K., AYRES, K., VYNNE, C.,GOBUSH, K., CANALES-ESPINOSA, D., RODRÍGUEZ-LUNA, E. (2010): Non-invasive measurement of thyroid hormone in feces of a diverse array of avian and mam-malian species. Gen Comp Endocrinol 168, 1–7.

WELTRING, A., SCHAEBS, F.S., PERRY, S.E., DESCHNER, T. (2012): Simultaneous measurement of endogenous steroid hormones and their metabolites with LC-MS/MS in faeces of a New World primate species, Cebuscapucinus. Physiol Beh 105, 510–521.

WILSON, M.I., BROWN, G.M., WILSON, D., (1978): An-nual and diurnal changes in plasma androgen andcortisol in adult male squirrel monkeys (Saimiri sciureus) studied longitudinally. Eur J Endocrinol 87, 424–433.

WINGFIELD, J.C., JACOBS, J., HILLGARTH, N. (2006): Ecological constraints and the evolution of hormone-behavior interrelationships. Ann NY Acad Sci 807, 22–41.

WU, A.H., GERONA, R., ARMENIAN, P., FRENCH, D.,PETRIE, M., LYNCH, K.L. (2012): Role of liquid chromato-graphy-high-resolution mass spectrometry (LC-HR/MS) in clinical toxicology. Clin Toxicol 50, 733–742.

WUDY, S.A., HARTMANN, M.F. (2004): Gas chromato-graphy-mass spectrometry pro� ling of steroids in times of molecular biology. Horm Met Res 36, 415–422.

ZIEGLER, T. (1996): Hormonal responses to parental and nonparental conditions in male cotton-top tamarins, Sa-guinus oedipus, a new world primate. Horm Behav 30, 287–297.

*Corresponding author’s address: Róisín Murtagh,Max Planck Institute for Evolutionary Anthropology,Deutscher Platz 6, 04103 Leipzig, Germany,e-mail: [email protected]